Product Solutions YOUR MOST VALUABLE QA & …€¦ · Product Solutions YOUR MOST VALUABLE QA &...

36
Product Solutions YOUR MOST VALUABLE QA & DOSIMETRY TOOLS T +31 (0)24 648 86 88 Nederland België / Belgique T +32 (0)3 309 32 09 www.gotoPEO.com [email protected]

Transcript of Product Solutions YOUR MOST VALUABLE QA & …€¦ · Product Solutions YOUR MOST VALUABLE QA &...

Page 1: Product Solutions YOUR MOST VALUABLE QA & …€¦ · Product Solutions YOUR MOST VALUABLE QA & DOSIMETRY TOOLS ... become part of a world-wide network of ... latest practices and

Product Solutions

YOUR MOST VALUABLE QA & DOSIMETRY TOOLS

T +31 (0)24 648 86 88

Nederland België / Belgique

T +32 (0)3 309 32 09 [email protected]

Page 2: Product Solutions YOUR MOST VALUABLE QA & …€¦ · Product Solutions YOUR MOST VALUABLE QA & DOSIMETRY TOOLS ... become part of a world-wide network of ... latest practices and

1 I www.lightages.com2 | SUN NUCLEAR CORPORATION // sunnuclear.com

Better Outcomes Through Technology .............................................5Innovation That Improves Outcomes While Saving Time..................6Total Solution Partner for Product Training & Support ................8 -11

ArcCHECK® ................................... 13MultiPlugTM .................................... 13CavityPlugTM .................................. 133DVH®............................................ 14Respiratory MotionSimTM ............... 14PlanIQTM ......................................... 15PerFRACTIONTM 2D & 3D .............. 15EPIDoseTM ...................................... 16MapCHECK® 2 .............................. 16MapPHANTM .................................. 17IVDTM 2 / rf-IVDTM 2 ........................ 18IsoRadTM ........................................ 18QEDTM ............................................ 18

Contents

PRODUCT SOLUTIONS // Table of Contents

Page 3: Product Solutions YOUR MOST VALUABLE QA & …€¦ · Product Solutions YOUR MOST VALUABLE QA & DOSIMETRY TOOLS ... become part of a world-wide network of ... latest practices and

sunnuclear.com // SUN NUCLEAR CORPORATION | 3

ATLASTM ......................................... 21Daily QATM 3 / rf-Daily QATM 3 ........ 21CHECKMATETM 2 ........................... 22

StereoPHANTM ............................... 25IC PROFILERTM .............................. 26PROFILERTM 2 ............................... 26TomoDoseTM .................................. 27SRS PROFILERTM .......................... 27IMFTM / GMFTM ............................... 28SNC MachineTM ............................. 28

3D SCANNERTM ............................. 313D MiniLiftTM .................................. 313D ReservoirTM ............................... 313D TPRTM ....................................... 31WaterProof PROFILERTM ............... 321D SCANNERTM ............................. 32PC ElectrometerTM ......................... 33EDGE DetectorTM ........................... 33SNC350pTM .................................... 34SNC125cTM .................................... 34SNC600cTM .................................... 35

Page 4: Product Solutions YOUR MOST VALUABLE QA & …€¦ · Product Solutions YOUR MOST VALUABLE QA & DOSIMETRY TOOLS ... become part of a world-wide network of ... latest practices and

1 I www.lightages.com4 | SUN NUCLEAR CORPORATION // sunnuclear.com

PRODUCT SOLUTIONS // Introduction

Page 5: Product Solutions YOUR MOST VALUABLE QA & …€¦ · Product Solutions YOUR MOST VALUABLE QA & DOSIMETRY TOOLS ... become part of a world-wide network of ... latest practices and

Independent and relevant quality assurance is more important than ever. Choosing a partner with a record of clinically-proven solutions and a history

of outstanding quality and service is just as important.

Sun Nuclear deals with the challenges confronting

every Radiation Oncology program: safe and

effective delivery of the intended prescriptions

and doses to patients. These challenges have

implications including:

• Patient Safety

• Patient Clinical Outcomes

• Facility Continual Improvement

• Facility Employee Satisfaction

• Facility Reputation for Quality

• Facility and Employee Accreditations/

Certifications

• Facility Financial Health

In choosing Sun Nuclear, you gain a partner with

more than 30 years of proven experience and you

become part of a world-wide network of cancer

treatment facilities committed to improving QA and

Dosimetry outcomes.

Resource Depth

Headquarter facilities and manufacturing are in

Melbourne, Florida, USA

2 linacs with photons, electrons, MLC, and EPID

1 Cobalt 60 teletherapy system

5 treatment planning and oncology information

systems

Better Outcomes

THROUGH TECHNOLOGY

MEDICAL PHYSICS | NUCLEAR MEDICINE | RADON MONITORING

sunnuclear.com // SUN NUCLEAR CORPORATION | 5

Page 6: Product Solutions YOUR MOST VALUABLE QA & …€¦ · Product Solutions YOUR MOST VALUABLE QA & DOSIMETRY TOOLS ... become part of a world-wide network of ... latest practices and

1 I www.lightages.com6 | SUN NUCLEAR CORPORATION // sunnuclear.com

Innovation that

IMPROVES OUTCOMES WHILE SAVING YOU TIME.Many companies claim to develop innovative products, but their products are not better or different than any other product. Our solutions are designed for you and the way you work, not the other way around. The result? Solutions that look and perform differently in a way that improves outcomes while saving you time.

PRODUCT SOLUTIONS // Innovation

Page 7: Product Solutions YOUR MOST VALUABLE QA & …€¦ · Product Solutions YOUR MOST VALUABLE QA & DOSIMETRY TOOLS ... become part of a world-wide network of ... latest practices and

The Right Detector for the Right ApplicationSun Nuclear manufactures both diode and ion chamber

detectors and arrays. Sun Nuclear’s SunPoint Diode

Detectors offer the benefit of a smaller active area,

better sensitivity, less drift and increased lifetime.

SunPoint Diode Detectors are used for small field/

patient-specific applications due to smaller size and

better performance characteristics for small and

modulated fields.

Ion chambers are used for large field/low-modulation

applications where small size is not necessary. Sun

Nuclear software also supports EPID, Gafchromic film,

and CR detectors.

Quick and Easy Setup

• Patented user calibration (Wide Field Calibration)

• USB communication with PC

• Single unit, lightweight designs

• Single cable for power and data

• No warm-up or pre-irradiation required

• Intuitive software for short learning curve

Independent

• Checks and balances using diodes, ion chambers,

EPIDs, and log files

• Independent from delivery and planning systems

• Measurement, and measurement-based calculations

• Not 100% reliant on calculation-only patient QA

Data Integrity and Transparency

• Original raw and processed data available to user

• Data export to spreadsheets

• Independently analyze any measurement data

• All algorithms documented in online help

Industry FirstsFirst Plan Quality Analysis Using Quantified Metrics

c. 2015, Quality Reports™

First Dose on patient geometry without a TPS dose

calculation c. 2010, 3DVH®

First EPID-based dose analysis for patient-specific IMRT

QA c. 2007, EPIDose™

First Patient-specific respiratory and gating simulation

system c. 2005, MotionSim™

First Electronic 2D Array for patient specific IMRT QA

c. 2002, MapCHECK®

First Daily QA trending database c. 1996, Daily QA™ Check

Corporate Partnerships

sunnuclear.com // SUN NUCLEAR CORPORATION | 7

LEADER - Sun Nuclear #1Worldwide Market Share

Leader for Quality and Safety

4,000 Worldwide Cancer Treatment Facilities Use Sun Nuclear Solutions

60 Countries with Sun Nuclear Solutions

90% of U.S. Cancer Centers Use Sun Nuclear Products

Sun Nuclear Training Center in Melbourne, FL,

4 Continents with Full-time Sun Nuclear Support Teams: Europe,

Asia, South America, North America

15 AAPM Task GroupMemberships

Page 8: Product Solutions YOUR MOST VALUABLE QA & …€¦ · Product Solutions YOUR MOST VALUABLE QA & DOSIMETRY TOOLS ... become part of a world-wide network of ... latest practices and

1 I www.lightages.com8 | SUN NUCLEAR CORPORATION // sunnuclear.com

At Sun Nuclear we know

THE VALUE OF EDUCATIONOngoing education is an important component of a successful continual improvement program, which ultimately helps to improve outcomes and patient safety. Sun Nuclear is a leader in the sharing of information and ideas from both industry and clinical perspectives. Our educational activities focus on both product and task-speci c subjects as well as broader issues in the radiation oncology industry.

PRODUCT SOLUTIONS // Training and Education

Page 9: Product Solutions YOUR MOST VALUABLE QA & …€¦ · Product Solutions YOUR MOST VALUABLE QA & DOSIMETRY TOOLS ... become part of a world-wide network of ... latest practices and

Live Product WebinarsSun Nuclear hosts live educational Product Webinars as part of its educational program. The webinars are hosted online, and are presented by clinical users and product experts. All webinars last approximately 30 minutes, with a live Q&A session following the webinar. Visit us online to register for our upcoming webinars. CE credits are available for select webinars. Register at sunnuclear.com/webinars.

Exploring the Future of QA and DosimetryThe QA & Dosimetry Symposium (QADS) is the only event for Medical Physicists and Dosimetrists that brings leading clinical innovators together to discuss the latest practices and issues related to QA and Dosimetry in Radiation Oncology. The symposium provides attendees with practical guidance from industry experts on new and relevant products, processes, and techniques in today’s evolving Radiation Oncology environment. The talk schedule is supplemented by opportunities to interact with leading industry vendors and colleagues in both professional and social settings. Register at qasymposium.com

Benefits• Continuing education credits (CAMPEP, SAM, and MDCB)

• Presentations from the industry’s leading authorities on the latest practices and

future direction of Radiation Oncology QA and Dosimetry

• Major vendor participation

• Leading resort venues

• Free registration for students and residents

• Web access to presentations after the symposium

• Networking with peers

sunnuclear.com // SUN NUCLEAR CORPORATION | 9

& DosimetrySYMPOSIUMExploring the future of QA and Dosimetry

The Sun Nuclear Training Center opened its doors in 2013. The training center is purpose-built, demonstrating Sun Nuclear’s commitment to patient safety and the effective use of QA solutions.

Users can experience in-depth exploration of Sun Nuclear product functionality on a linac, as well as application-specific coursework such as IMRT QA, VMAT QA, Annual QA, and Commissioning. The training center offers this training in an environment that closely mimics an actual clinical setting for a realistic learning experience.

Training courses on a variety of subjects are offered year round and are delivered by Sun Nuclear subject matter experts and experienced clinical users. Details on upcoming training courses are posted on the Sun Nuclear Support website.

Quality Content

Hands-on Learning

Why the Sun Nuclear

Peer-to-Peer Instruction

State-of-the-Art FacilityTake a virtural tour of the Training Center at sunnuclear.com/training

Page 10: Product Solutions YOUR MOST VALUABLE QA & …€¦ · Product Solutions YOUR MOST VALUABLE QA & DOSIMETRY TOOLS ... become part of a world-wide network of ... latest practices and

1 I www.lightages.com10 | SUN NUCLEAR CORPORATION // sunnuclear.com

Total Solution Partner for

PRODUCT TRAINING & SUPPORTWe are committed to providing customers with the best possible support experience. Sun Nuclear’s Support team includes over twenty professionals with diverse physics, teaching, engineering, customer support, and language skills. As always, Sun Nuclear customers receive complimentary standard technical support, and there is never a limit to the number of times you may contact us with a question.

PRODUCT SOLUTIONS // Training and Education

Page 11: Product Solutions YOUR MOST VALUABLE QA & …€¦ · Product Solutions YOUR MOST VALUABLE QA & DOSIMETRY TOOLS ... become part of a world-wide network of ... latest practices and

Training Matrix On-site Online In-house On-site Online In-house

Trained Sun Nuclear professional on site Y - Y Remote assistance with installation of software Y Y -

Comprehensive syllabus Y Y Y Assist with acquisition of sample measurements Y - Y

Provides users with in-depth and effi cient

product use experienceY Y Y Train users on comprehensive product functionality Y Y Y

Training on advanced features Y Y Y Question and answer (Q&A) session Y Y Y

Training on real-time operation of the software Y Y Y Maximize benefi ts of the product(s) purchased Y Y Y

Secure Internet connection with unlimited

customer attendeesY Y -

Shorten learning curve and begin using

product(s) sooner Y Y Y

Oversee and physically assist with installation of

devices and softwareY - Y

Product TrainingAll Sun Nuclear products are designed for easy installation and setup. As an added service, Sun Nuclear o ers professional product installation and training for all products. Customers have three options to choose from:

Option 1: On-site Installation and Training

Option 2: Online Product Training

Option 3: In-house Product Training at the Sun Nuclear Training Center

Worldwide: Standard Sun Nuclear telephone support is o ered from 8am to 8pm ET, Monday through Friday.

Regional: Standard extended regional telephone support hours are available.

After hours/on-call telephone support options are available.

Secure Remote SupportSun Nuclear users who have a current maintenance contract may request live online assistance.

Online assistance allows trained Sun Nuclear support professionals to collaborate directly in the user’s PC environment to evaluate and resolve issues, relieving the user of this task.

Sun Nuclear Support Website which provides the following bene ts:

• Access to software, manuals, and software license keys in

real time for your products.

• Exclusive instructional material including videos and FAQs.

• Sun Nuclear account management (inventory of products

and product details).

• Ability to request information and support.

Visit sunnuclear.com/support

sunnuclear.com // SUN NUCLEAR CORPORATION | 11

Telephone Sun Nuclear Support SiteAll Sun Nuclear users have access to an exclusive, user-only

Page 12: Product Solutions YOUR MOST VALUABLE QA & …€¦ · Product Solutions YOUR MOST VALUABLE QA & DOSIMETRY TOOLS ... become part of a world-wide network of ... latest practices and

Sophisticated treatment options such as Arc, Helical, IGRT, IMRT, and SRS demand equally sophisticated patient specific QA. Modern patient plans are often collections of small beamlets with very steep dose gradients.

Since these dose gradients are too tightly to conform to patient anatomy and PTV accurate veri cation of the dose gradient is critical. Using the right technology is critical. Sun Nuclear o ers a variety of sophisticated treatment options using our advanced

diode detectors, which measure actual delivered dose without the misleading and often hidden e ects of dose volume averaging as seen in ionization chambers.

Sophisticated Treatment Options Demand

PATIENT SPECIFIC QA

1 I www.lightages.com12 | SUN NUCLEAR CORPORATION // sunnuclear.com

PRODUCT SOLUTIONS // Patient QA

Page 13: Product Solutions YOUR MOST VALUABLE QA & …€¦ · Product Solutions YOUR MOST VALUABLE QA & DOSIMETRY TOOLS ... become part of a world-wide network of ... latest practices and

Cavity Options

Applications• Patient plan QA

RapidArc®/VMAT, FFF, SmartArc and TomoTherapy®

Routine IMRT and 3D conformal

• Machine and setup QA

Highlights• The world’s first true 4D detector array

• The world’s first cylindrical detector array

• The world’s first electronic array designed specifically for

rotational dosimetry

ey Bene ts• Utilizes SunPoint® Diode Detectors

• Consistent BEV regardless of gantry angle

• High detector density in BEV

• 221 detectors in central 10 x 10 cm

• Easy setup and lightweight (16 kg)

• Measure both composite and per control point

• Real-time updates (50 ms)

Detector Type: SunPoint Diode Detectors

Detector Quantity: 1386

Detector Spacing (cm): 1.0

Array Diameter (cm): 21.0

Inherent Buildup (g/cm2): 3.3 +/- 0.1

Inherent Backscatter (g/cm2): 3.3 +/- 0.1

Array Geometry: Helical Grid, 1 cm offset

Phantom Material: PMMA (Acrylic)

Weight (kg): 16

Applications• IMRT, Arc, SRS, SBRT dose distributions in cavity

• Supports 3DVH®

Highlights• Precision fitted for ArcCHECK central cavity

• Accepts ion chambers, diodes, film detectors

• Position single detectors in any of 25 unique locations

• Position film sizes up to 13 x 21 cm in X or Y axis

• Angle indicator allows rotation to any angle within

ArcCHECK cavity

Applications• Measures dose at isocenter

• Supports 3DVH

sunnuclear.com // SUN NUCLEAR CORPORATION | 13

ArcCHECK®

MultiPlug™

CavityPlug™

Page 14: Product Solutions YOUR MOST VALUABLE QA & …€¦ · Product Solutions YOUR MOST VALUABLE QA & DOSIMETRY TOOLS ... become part of a world-wide network of ... latest practices and

Supports Coplanar & Non-Coplanar Beams: Yes

Estimation of Absolute Patient Dose: Yes

Analysis by Patient DVH: Yes

Accounts for TPS error: Yes

Accounts for Beam Delivery Error: Yes

Statistics per Anatomical Structure: Yes

DICOM RT Compatibility: Full integration

VMAT and RapidArc® Support: Yes

Analysis of Beam by Beam Errors: Yes

Applications• 3D or 4D patient dose QA using ArcCHECK®,

MapCHECK® 2, EPIDose™, or Film

• IMRT, VMAT, and Conventional Patient QA

• Effective tool for commissioning

• Coplanar and non-coplanar deliveries

Highlights• Create an estimated 3D or 4D patient dose volume for QA

• Structure-based analysis tools

• Intuitive and powerful user interface

• Generate easy-to-read QA reports

• Create high density, high resolution dose reconstruction in

ArcCHECK volume with Virtual Gel™

• Evaluate the effects of structure motion on estimated

patient dose distribution with optional Respiratory

MotionSim

ey Bene ts• Clinically relevant patient QA

• Eliminates dose to phantom guesswork

• No commissioning required

Applications• Respiratory dosimetric effects simulation

• Prostate and other non-cyclical motion simulation

• Gating dosimetric effects simulation

• IMRT, VMAT, and Conventional Patient QA

Highlights• Quantify and visualize the effects of structure motion on

the estimated patient dose distribution, including DVH

• Patient-specific respiratory patterns imported from 4DCT -

manual entry of trajectory data not required

• Interplay effect simulation - averages possible interplay

effects over multiple fractions

• Track individual voxels as a function of time

• Movie mode features 4D playback of dose accumulation,

motion, and time

• Customize moving target, margin, direction of motion,

one-time/repeating motion, etc.

ey Bene ts• Allows quantification of patient-specific motion effects

on 3D dose distribution in patient anatomy

• No additional setup or phantom required

• Motion effects are fully patient specific

• Dose distributions in patient anatomy and geometry

• No commissioning

• Fully integrated with 3DVH

1 I www.lightages.com14 | SUN NUCLEAR CORPORATION // sunnuclear.com

3DVH®

Respiratory MotionSim™

3DVH Options

PRODUCT SOLUTIONS // Patient QA

Page 15: Product Solutions YOUR MOST VALUABLE QA & …€¦ · Product Solutions YOUR MOST VALUABLE QA & DOSIMETRY TOOLS ... become part of a world-wide network of ... latest practices and

Meets Reimbursement Requirements: Yes

Supports all Treatment Modalities: Yes

Independent Check: Yes

Access From any Computer on Network: Yes

Detects Patient Setup Errors: Yes

Detects Patient Anatomy Changes: Yes

Detects Output Fluctuations: Yes

Detects Machine MLC, Jaws/Collimator Errors: Yes

Commissioning Required: No

Browser Support: Chrome, IE8, IE9

Applications• Fraction 0: Pre-Treatment IMRT QA without a phantom (3D)

• Fraction n: Treatment delivery QA for every fraction (2D & 3D)

Highlights• Completely automated workflow captures and analyzes all

necessary files and emails if a failure - no further work required

• 2D planar comparison to baseline and/or predicted images

• 3D dose reconstruction on patient CT using proprietary

collapsed cone convolution superposition algorithm (3D)

• Point dose and region of interest calculations (3D)

• Clinical goals pass/fail calculation (3D)

• AutoCalTM - automated EPID response calibration feature

corrects for EPID drift

• Included SNC Server streamlines installation

• Web-browser access from any computer on your network

• Works with Varian, Elekta, Aria, Mosaiq

ey Bene ts• Consistent system for both pre-treatment QA (Fraction 0)

and per-fraction QA (Fraction n)

• Complete automation - no additional time requirements -simply

approve results when ready

• Detects the most common types of errors - patient errors - as

well as machine errors

• EPID-based Measurement QA solution maintains

independence and billing compliance (US)

sunnuclear.com // SUN NUCLEAR CORPORATION | 15

PerFRACTION™ 2D & 3DPlanIQ™

Applications• Clinical goal feasibility and plan optimization

• Plan quality scorecards and improvement

• Commission auto-treatment planning systems

• Plan documentation

Highlights• Determine feasibility of the clinical goals before planning begins

• Optimize clinical goals with Feasibility DVH which show what

DVH are feasbile for each target and OAR

• Plan Quality Metrics (PQM and APQM) provide patient specific

plan quality scoring, for entire plan and for each target and OAR

• Choose from over 70 pre-defined quality protocols to score

against and customize

• Single comprehensive report for complete patient treatment

plan and quality scoring for compliance

• DVH QA to support TG-53 compliance

• Record patient quality metrics to quality library, and

demonstrate continual improvmeent

ey Bene ts• No time wasted on treatment planning of ambiguous or

unachievable goals

• Higher quality treatment plans

• Easier compliance with documentation and quality

requirements

More than simple pass/fail of objectives: Yes

Takes into account patient specifi c challenges: Yes

Drives continuous improvement: Yes

Compatible with all TP and R&V Systems: Yes

Supports all Treatment Modalities: Yes

Vendor-Neutral DVH QA: Yes

Dedicated DICOM Server: Yes

Compatible with 3DVH®: Yes

Interactive visualization of DICOM Data: Yes

Customizable Reports: Yes

Page 16: Product Solutions YOUR MOST VALUABLE QA & …€¦ · Product Solutions YOUR MOST VALUABLE QA & DOSIMETRY TOOLS ... become part of a world-wide network of ... latest practices and

Applications• Quick conversion of MV EPID images to absolute dose

• Absolute Dose Commissioning using MapCHECK® 2

Highlights• EPID based patient plan QA

MV EPID images to absolute

Comparison, subtraction, overlay, profiles

Rotational delivery support

• Supports all delivery modalities and linacs

Any EPID distance or dose plane setup

• Independent of treatment planning system and linac

Patented algorithm tests TPS calculations - Catch errors

missed by image QA

Use with 3DVH® software

ey Bene ts• Easy to Use

No buildup on EPID

Combine split fields

Maximize the benefits of MV EPID

• Absolute Dose Commissioning using MapCHECK® 2

• Corrections of per segment output factor variation and

phantom scatter

Independent Dose Comparisons: Yes

Increased Data Density for QA: Yes

Audit the TPS and Delivery System: Yes

No Buildup on EPID: Yes

Measure at Any Gantry Angle: Yes

One Model Works with Each:

Linac/EPID

Photon energy

Source to EPID

Source to Dose plane

Dose plane depth

1 I www.lightages.com16 | SUN NUCLEAR CORPORATION // sunnuclear.com

EPIDose™

Applications• Patient plan QA

IMRT QA

RapidArc®/VMAT, FFF and TomoTherapy®

(with accessories)

• Machine, MLC, and setup QA

Highlights• Most detectors of any 2D array

• Highest detector density of any 2D array

• Largest field size of any 2D array

• MapCHECK 2 is a turn-key solution

ey Bene ts• Proven solution for film-less rotational and IMRT delivery

• Utilizes SunPoint® Diode Detectors

• Easy to use and efficient software

• Single click comparisons

• Rotational capable when used with MapPHAN option

• Real-time updates (50 ms)

• Interfaces with the IMF™

Detector Type: SunPoint Diode Detectors

Detector Quantity: 1527

Detector Spacing (mm): 7.07

Array Size (cm): 32.0 x 26.0

Inherent Buildup (g/cm2): 2.0 ± 0.1

Inherent Backscatter (g/cm2): 2.7 ± 0.1

Array Geometry (cm):Detector spacing parallel

to X and Y axes: 1.0

Row spacing: 0.5

Phantom Material: PMMA (Acrylic)

Weight (kg): 7.1

MapCHECK®2

PRODUCT SOLUTIONS // Patient QA

Page 17: Product Solutions YOUR MOST VALUABLE QA & …€¦ · Product Solutions YOUR MOST VALUABLE QA & DOSIMETRY TOOLS ... become part of a world-wide network of ... latest practices and

Applications• Patient plan QA for rotational delivery

RapidArc®/VMAT, FFF and TomoTherapy®

Coronal and sagittal orientation

Construction: Virtual WaterTM

Available Depths (cm): 5.0 cm, 10.0

Area (cm2): 35.0 x 38.0

Weight (kg): 8.0 (5 cm), 21.0 (10 cm)

sunnuclear.com // SUN NUCLEAR CORPORATION | 17

MapPHAN™

MapCHECK 2 Options

PerFRACTION™

“Over the duration of the study, multiple MLC positional errors were detected using the EPID based software but these same errors were not detected using the trajectory log les.

“Monitoring daily MLC positional errors using trajectory log les and EPID

measurements for IMRT and MAT deliveries, A. Agnew, et al., 2014 Phys. Med. Biol. 59 N49

Page 18: Product Solutions YOUR MOST VALUABLE QA & …€¦ · Product Solutions YOUR MOST VALUABLE QA & DOSIMETRY TOOLS ... become part of a world-wide network of ... latest practices and

Highlights• Flat design for easy placement on patient

• Accurate and stable SunPoint Diode Detector

ey Bene ts• Real-time dose reading

Highlights• Cylindrical design for isotropic response

• Accurate and stable SunPoint® Diode Detector

ey Bene ts• Real-time dose reading

15-2

5 MV

1-4 M

V

6-12

MV

1-4MV

6-12

MV

15-25

MV

ELECTR

ON

SKINDetector Area (mm2): 1.54

Active Dimension (mm): 1.4 diameter

Dose Rate Dependence (cm): ± 1%, 75 - 250 SSD

Detector Sensitivity (nC/Gy): 27

Detector Stability: 0.5% /kGy at 6 MV

Detector Area (mm2): 0.64

Active Dimension (mm): 0.8 x 0.8

Dose Rate Dependence (cm): ± 1%, 75 - 250 SSD

Detector Sensitivity (nC/Gy): 32

Detector Stability: 0.5% /kGy at 6 MV

1 I www.lightages.com18 | SUN NUCLEAR CORPORATION // sunnuclear.com

ISORAD™ DetectorIVD™ 2 rf-IVD™ 2/

QED™ Detector

Applications• Dose verification during treatment

• Final check of complete system

• Total Body Irradiation (TBI)

Highlights• Real-time wireless option available (rf-IVD 2)

• Use with control module or PC software

• Expandable to 52 channels, 4 channels standard

• Record and verify interface

ey Bene ts• Simple to install and easy to use

• Automatic patient temperature compensation

• 12 calibration keys

• Patient database

• Correction factor tools

• Accuracy and reliability proven worldwide

• Use with industry standard re-usable detector options

QED - Flat for easy patient placement

ISORAD - Cylindrical for isotropic response

Channels:Standard: 4

Maximum: 52

Temperature Compensation:

Automatic-within 0.10 C

(Negative polarity only)

Repeatability (cGy): ± 0.2% or ± 0.1

Polarity:Bipolar (negative or positive

polarity detectors)

Leakage: Automatic compensation

Warm-Up Time: < 30 sec

Power:rf-IVD 2 : Rechargeable NiMH

battery (12 hr)

IVD 2 : Power supply

Weight (kg): 0.34

PRODUCT SOLUTIONS // Patient QA

Page 19: Product Solutions YOUR MOST VALUABLE QA & …€¦ · Product Solutions YOUR MOST VALUABLE QA & DOSIMETRY TOOLS ... become part of a world-wide network of ... latest practices and

sunnuclear.com // SUN NUCLEAR CORPORATION | 19

“We are using the ArcCHECK for about a year now for QA of our clinical IMRT plans. On the basis of our experiences we can conclude that the ArcCHECK is not only suitable for the QA of Elekta linacs, but also for small stereotactic elds up to x cm2) from a

Novalis® linac Brainlab).

Dr. Paul Rietveld, Ph.D.Radiotherapiecentrum, The Netherlands

ArcCHECK®

Page 20: Product Solutions YOUR MOST VALUABLE QA & …€¦ · Product Solutions YOUR MOST VALUABLE QA & DOSIMETRY TOOLS ... become part of a world-wide network of ... latest practices and

Routine daily, monthly, and annual tests are prescribed as part of a robust QA and Dosimetry program. For the person taking the routine measurement, tools must be easy to use and reliable.

The physics goal of routine QA is to maximize the data integrity and analysis options. Sun Nuclear is the only company to achieve this goal by o ering a daily device with 25 detectors that performs ve uni ue tests in a single measurement. This goal is

carried a signi cant step further with ATLAS, which centralizes all routine QA and Dosimetry test data in one location, o ering new opportunities in reporting, analysis, and e ciency.

Maximize Data Integrity and

ANALYSIS OPTIONS

1 I www.lightages.com20 | SUN NUCLEAR CORPORATION // sunnuclear.com

PRODUCT SOLUTIONS // Routine

Page 21: Product Solutions YOUR MOST VALUABLE QA & …€¦ · Product Solutions YOUR MOST VALUABLE QA & DOSIMETRY TOOLS ... become part of a world-wide network of ... latest practices and

ATLAS™

Applications• Radiotherapy center QA management

• Scheduling, equipment, and messaging management

Highlights• A front end for data acquisition

• A back end for reporting and analysis

• Suitable for both small and large facilities

• Upload documents to the Attachment Center

• Audit Log shows overdue/failed test

Searches Attachment Center for documents that have

expired or are about to expire

Tests can be cloned either as a group or individually to a

new machine

ey Bene ts• Integrated test libraries

• Customizable tests

• Resource tracking management

• Facility and user management

• Attachments

• TG-142 and TG-51 libraries

Organization Structure:Daily, monthly, annual, dosimetry,

mechanical, safety, and imaging

Test Libraries:TG-40, TG-142, TG-51

Manufacturer recommended

Customize Tests: Yes

Resource Tracking: Yes

User Management: Yes

Communication Center: Yes

Data Management: Yes

Networkable: Yes

Applications• Daily linac monitoring and trending

Output, flatness, symmetry, energy, light-radiation

field coincidence

• Rotational delivery supported

Highlights• Utilizes both ion chambers and diodes for optimal results

• Measure output, flatness, symmetry, field size, energy in a

single exposure

• Trend analysis database software included

• No warm-up or pre-irradiation required

• Real-time wireless available (rf-Daily QA 3)

ey Bene ts• No buildup or flipping required

• Automatic temperature and pressure correction

• Real-time measurements

• Simple two-step operation

Start and then Record

Interfaces with the IMF™

Detector Type:Sun Point® Diode Detectors

Vented Ion Chambers

Detector Quantity:Diodes: 12 total

Chambers: 13 total

Detector Spacing (mm): Diodes: 5

Chamber Active Value (cm3): Electron: 0.6; Photon: 0.3

Inherent Buildup (g/cm2): Chambers: 1.0 ± 0.1

Inherent Backscatter (cm): 2.3

Field Size (cm): 20 x 20

Weight (kg): 5.7

Daily QA™ 3 / rf-Daily QA™3

sunnuclear.com // SUN NUCLEAR CORPORATION | 21

Page 22: Product Solutions YOUR MOST VALUABLE QA & …€¦ · Product Solutions YOUR MOST VALUABLE QA & DOSIMETRY TOOLS ... become part of a world-wide network of ... latest practices and

Detector Type: Vented Ion Chamber

Detector Quantity: 1 - CAX

Parallel Plate Separation (mm): 4.0

Field Sizes (cm): 10 x 10 and 20 x 20

Detector Volume (cm3): 0.6

Inherent Buildup (g/cm2): 1.0 ± 0.1

Inherent Backscatter (cm): PMMA, 2.3

Weight (kg): 4.9

CHECKMATE™ 2

1 I www.lightages.com22 | SUN NUCLEAR CORPORATION // sunnuclear.com

PRODUCT SOLUTIONS // Routine

Applications• Daily central axis output

• Repeatability

• Monitor chamber linearity

Highlights• Built-in rechargeable batteries

• Precision alignment template

• User calibration

• Stores up to 15 calibration values

Automatic memory position advance

ey Bene ts• Cost effective solution

• Simple to use

• Automatic temperature and pressure correction

Large, easy to read display

Page 23: Product Solutions YOUR MOST VALUABLE QA & …€¦ · Product Solutions YOUR MOST VALUABLE QA & DOSIMETRY TOOLS ... become part of a world-wide network of ... latest practices and

sunnuclear.com // SUN NUCLEAR CORPORATION | 23

“The chamber to chamber variation, combined with the IC PROFILER™ 2D array’s calibration stability with time feature has been proven to be suf ciently stable for the device to be used to signature water phantom performance in line with Elekta’s manufacturing needs.

Craig HuntServices Product Specialist

Oncology Services DevelopmentElekta Ltd.

IC PROFILER™

Page 24: Product Solutions YOUR MOST VALUABLE QA & …€¦ · Product Solutions YOUR MOST VALUABLE QA & DOSIMETRY TOOLS ... become part of a world-wide network of ... latest practices and

Machine QA should be performed with three primary goals in mind. The first is to foresee an issue before it occurs; the second is to identify an issue as soon as it is measureable; and the third is to apply prior understanding to improve the machine output and stability, and the overall QA program. Many of these goals are re ected in international QA guidelines, and many are easily and accurately accomplished using Sun Nuclear’s line of Machine QA tools. Since the introduction of the PROFILER in 1996, through PROFILER 2,

TomoDose, SRS PROFILER, StereoPHAN, IC PROFILER, and SNC Machine, Sun Nuclear is committed to meeting and exceeding the goals of Machine QA regardless of the challenge or delivery modality.

Improve Machine Output

STABILITY AND OVERALL QA

1 I www.lightages.com24 | SUN NUCLEAR CORPORATION // sunnuclear.com

PRODUCT SOLUTIONS // Machine QA

Page 25: Product Solutions YOUR MOST VALUABLE QA & …€¦ · Product Solutions YOUR MOST VALUABLE QA & DOSIMETRY TOOLS ... become part of a world-wide network of ... latest practices and

Applications• Brainlab®

• Fraxion® GammaKnife®

• CyberKnife®

StereoPHAN™

Applications• Stereotactic (SRS/SRT/SBRT) end-to-end testing

• Quality assurance of image fusion algorithms for CT and

MRI imaging modalities

• Absolute, relative and point dose dosimetry QA

measurements at isocenter with ion chambers; relative

dose distribution using film

Highlights• Consistent orientation allows for interference-free dose

measurement regardless of measurement plane

• Target volumes in CT/MRI cube eliminate need for

CT/MRI markers

• Flat surface of ion chamber cube geometry enables easy

cross-calibration to water

• Support for stereotactic frame and frameless systems

Key Benefits

• Phantom stand holds the inserts, making them easily

accessible during testing

• Multi-functional cube inserts increase efficiency

• No tools required for assembly

• Stand base can be mounted to a couch that uses the

Lok-Bar™ system

• All components fit into durable rolling case suitable for

storage and travel

Material: PMMA (Acrylic)

Weight (Including all Inserts) (kg): 11.1

Measurement Cubes (mm): 85 x 85 x 85

StereoPHAN Dimensions (mm): 518 x 276 x 323

sunnuclear.com // SUN NUCLEAR CORPORATION | 25

Film CT Ion Chamber

Film Ion chamber

StereoPHAN Options

SRS/SBRT Headframes

CT/MRI

MRI Signal

Generator

Universal Spacer

StereoPHAN Inserts

CyberKnife® Support

Page 26: Product Solutions YOUR MOST VALUABLE QA & …€¦ · Product Solutions YOUR MOST VALUABLE QA & DOSIMETRY TOOLS ... become part of a world-wide network of ... latest practices and

Applications• Alternative to a water phantom for many tests

Flatness, symmetry, field size, beam center, penumbra

width, light-radiation field coincidence

• Real-time beam constancy, steering, diagnostics

• Evaluate collimator and rotational sag

• Profile comparison, subtraction, and overlay

Identify startup/time dependent anomalies

Highlights• Quick and precise beam QA measurement

• Sets up in minutes versus hours for a typical water tank

• Multiple real-time parameter calculations

• No warm-up or pre-irradiation required

• Import water tank data and compare to PROFILER files

Key Bene ts• Real-time beam measurements

• Fast and efficient setup

• One measurement checks multiple parameters

• Interfaces with the IMF™

Detector Type: SunPoint® Diode Detectors

Detector Quantity: 139 Total: X Axis: 57 / Y Axis: 83

Detector Spacing (mm): 4

Array Size (cm): 22.4 x 32.8

Inherent Buildup (g/cm2): 1.0

Inherent Backscatter (g/cm2): 2.0

Phantom Material: Virtual Water™ top plate

Weight (kg): 5.0

1 I www.lightages.com26 | SUN NUCLEAR CORPORATION // sunnuclear.com

PROFILER™ 2

PRODUCT SOLUTIONS // Machine QA

IC PROFILER™

Applications• Full field measurement instead of a single point

• Beam constancy, steering, diagnostics

• Comprehensive linac QA

Highlights• With appropriate calibration, the IC PROFILER has an

accuracy within 0.5% of a water tank

• Unique curved ion chamber design maximizes signal

and minimizes volume averaging

• Very low noise to signal ratio (0.15%)

Key Bene ts• 45 cm length diagonals

• 0 x 40 cm field measurement at 75 cm SDD

• Maximum dose rate of 6660 cGy/min

Detector Type: Parallel plate Ion Chamber

Detector Quantity:251 Total: X Axis: 63 / Y Axis: 65

-Diagonal: 63 / +Diagonal: 63

Detector Spacing (mm): 5.0

Array Size (cm): 32.0 x 32.0

Detector Volume (cm3): 0.046

Detector Sensitivity (pC/cGy): 14.4

Inherent Buildup (g/cm2): 0.9

Inherent Backscatter (g/cm2): 2.3

Phantom Material: PMMA (Acrylic) / PC

Weight (kg): 8.8

Page 27: Product Solutions YOUR MOST VALUABLE QA & …€¦ · Product Solutions YOUR MOST VALUABLE QA & DOSIMETRY TOOLS ... become part of a world-wide network of ... latest practices and

Applications• Use for Machine QA on TomoTherapy® Hi-Art®

• Post component replacement verification

• Daily QA tests

Highlights• Only array designed for TomoTherapy Hi-Art

• Measure entire Hi-Art beam in a single measurement

• Accessibility to raw data

• Import water tank data and compare to TomoDose files

Key Bene ts• Fast and efficient setup

• Ten measurement axes for both X and Y direction

• Measure output, symmetry, flatness, field size, penumbra,

beam center

• Analyze and compare up to 15 profiles at once

• Instantaneous dose rate plot

Detector Type: SunPoint Diode Detectors

Detector Quantity: 223 total on X and Y

Detector Spacing (mm): X: 5.0, Y: 4.0, Y Off-axis: 8.

Array Size (cm): 53.0 x 9.8

Array Geometry (cm): X: 53.0 Y: 9.8 (8.0 at ±19.0)

Inherent Buildup (g/cm2): 1.0

Inherent Backscatter (g/cm2): 2.8

Phantom Material: PMMA (Acrylic)

Weight (kg): 5.0

Applications• SRS cone based radiation therapy

On Accuray® Recommended QA Equipment list

• Daily, monthly, and annual machine QA

Highlights• Array is designed for cone based SRS

• Accepted and proven for clinical and factory settings

• Import water tank data and compare to PROFILER files

• Real-time analysis

Key Bene ts• Fast and efficient setup

• Identify startup/time dependent anomalies

• One measurement checks multiple parameters

• Attaches to the CyberKnife® birdcage

Detector Type: SunPoint® Diode Detectors

Detector Quantity: 125 total on four axes

Detector Spacing (mm): 4

Radial Field Size (mm): 10, 20, 40, 60, 80, 100, and 120

Axes Length (mm): 143 (X), 127 (Y), 124 (Diagonals)

Inherent Buildup (g/cm2): 0.5

Phantom Material: PMMA (Acrylic)

Weight (kg): 1.5

sunnuclear.com // SUN NUCLEAR CORPORATION | 27

SRS PROFILER™TomoDose™

Page 28: Product Solutions YOUR MOST VALUABLE QA & …€¦ · Product Solutions YOUR MOST VALUABLE QA & DOSIMETRY TOOLS ... become part of a world-wide network of ... latest practices and

Applications• TG-142 imaging and mechanical QA

• VMAT mechanical and dosimetric QA

Highlights• Comprehensive pre-defined test library for TG-142 and VMAT QA

• Completely automated workflow captures and analyzes all

necessary files - no further work required

• Easy phantom baseline setup with automatic ROI registration

• Trend any test or test parameter against any other test or test

parameter for any number of machines

• Included SNC Server streamlines installation

• Supports most common imaging and mechanical QA

phantoms for TG-142

• Web-browser access from any computer on your network

• Works with Varian, Elekta, Aria, Mosaiq

Bene ts• Complete library of most common TG-142 imaging and

mechanical tests

• Complete automation - no additional time requirements -

simply approve results when ready

SNC Machine™

1 I www.lightages.com28 | SUN NUCLEAR CORPORATION // sunnuclear.com

PRODUCT SOLUTIONS // Machine QA

Compatible Linacs: (IMF) Elekta, Siemens, Varian

Weight (kg): (IMF-E) 7.9, (IMF-S) 8.1, (IMF-V) 7.4

Maximum Buildup (cm): (IMF)

Dimensions (cm):(IMF-E) 39.4 x 28.7 x 48.8

(IMF-S) 39.4 x 31.5 x 48.0

(IMF-V) 39.4 x 31.5 x 39.1

Compatible Linacs: (GMF) Elekta, Varian

Weight (kg): (GMF-E) 16.8, (GMF-V) 3.7

Maximum Buildup (cm):(GMF-E, ICP only) 3

(GMF-V, ICP only) 1.5

Dimensions (cm):(GMF-E) 56.5 x 56.5 x 56.0

(GMF-V) 40.0 x 47.1 x 42.2

Applications• Measure output, symmetry, flatness, field size,

penumbra, beam center, and more at any angle.

• Determine gravity-induced dose constancy, symmetry,

flatness, MLC and jaw shift changes

• Holds cones of 20 x 20 cm or less for performing

electron measurements

Highlights• Hold device measurement planes at machine isocenter:

IMF: MapCHECK®, MapCHECK 2, PROFILER™ 2,

Daily QA™3, rf-Daily QA3, and SRS PROFILER™ with

adapter plat

GMF: MapCHECK 2, PROFILER 2 and Daily QA 3

(adapter plate required)

Key Bene ts• Fast, efficient, reproducible setup

• Measure at 100 cm SDD +/- 1.0 mm

• Supports electron cone (GMF)

• Aluminum alloy construction

Adjustable buildup clamps

IMF™ GMF™/

Tests

TG-142 Imaging:

CBCT Image Quality & Accuracy, kV Image Quality & Accuracy, MV Image Quality & Accuracy

TG-142 Mechanical:

MLC Picket Fence, MLC Positioning & Leaf Speed, Winston-Lutz Radiation & Machine Isocenter, Gantry/Couch/Collimator Starshot, Light/Radiation Congruence, Field Size

Beam: Beam Flatness, Beam Symmetry

VMAT:Dose Rate versus Gantry Speed, Leaf Speed, Arc Point Dose, DMLC Point Dose

Page 29: Product Solutions YOUR MOST VALUABLE QA & …€¦ · Product Solutions YOUR MOST VALUABLE QA & DOSIMETRY TOOLS ... become part of a world-wide network of ... latest practices and

Applications• Image scaling, positioning offset, spatial resolution,

contrast, uniformity and noise

• Easy setup, alignment clearly marked on overlay and image

Applications• Symmetric and asymmetric light field/radiation field

coincidence and jaw positioning

• Flatness and symmetry for photon and electron beam

profile constancy

Applications• Winston-Lutz measurements

• Imaging and radiation field isocenter coincidence

• Cone-beam CT positioning/repositioning

• End-to-end IGRT positioning tests

• 3D isocenter offset results

Dimensions (cm): 6.0 x 6.0 x 6.0

Sphere Size (mm): 7.0

Sphere Center Accuracy (mm): 0.2

Field Sizes (cm): 10 x 10; 15 x 15

Markers (±0.1mm): 56 - Field size (7 per fi eld edge)

Dimensions (cm): 17.8 L x 17.8 W x 0.6 D

MV Line Pairs (mm): 0.1, 0.2, 0.5, 1.0 ± 0.025

MV ROI: 9 (4 spatial, 4 contrast, 1 center)

MV Dimensions (cm): 12.7 L x 10.2 W x 2.5 D

Applications• I mage scaling, positioning offset, spatial resolution, contrast,

uniformity and noise

• Easy setup, alignment clearly marked on overlay and image

kV Line Pairs (mm): 0.6, 1.2, 1.8, 2.4 ± 0.01

kV ROI: 28 (4 spatial, 23 contrast, 1 center)

kV Dimensions (cm): 12.7 L x 12.7 W x 1.6 D

sunnuclear.com // SUN NUCLEAR CORPORATION | 29

SNC Machine Options

MV-QA FS-QA: Field Size QA and Constancy

kV-QA WL-QA: Isocenter QA and Constancy

SNC Machine Compatability

R&V Systems: ARIA® and MOSAIQ® with Varian® linacs

kV:ImagePro kV , LEEDS TOR 18FG, Standard Imaging QC-kV1

MV:ImagePro MV, Varian Las Vegas, Standard Imaging QC-3

CBCT:Varian CATPHAN (Model 504), ElektaCATPHAN (Model 503), CATPHAN 600, Gammex 464

Winston-Lutz: ImagePro WL-QA, custom phantom

Field Size: ImagePro FS-QA, custom phantom

Log Files: Varian Dynalog

Browsers:IE9 with Windows 7; IE 11 with Windows 8.1; Google Chrome

Page 30: Product Solutions YOUR MOST VALUABLE QA & …€¦ · Product Solutions YOUR MOST VALUABLE QA & DOSIMETRY TOOLS ... become part of a world-wide network of ... latest practices and

Tools used for dosimetry and commissioning must be carefully selected. Equal care must be taken to use the tools properly, otherwise incorrect information could be used with serious consequences. It is with this understanding that Sun Nuclear designs dosimetry solutions. Our goal for dosimetry is to maximize the accuracy of the measurement while minimizing the possibility of incorrect use.

Maximize Measurement Accuracy While

MINIMIZING INCORRECT USE

1 I www.lightages.com30 | SUN NUCLEAR CORPORATION // sunnuclear.com

PRODUCT SOLUTIONS // Dosimetry

Page 31: Product Solutions YOUR MOST VALUABLE QA & …€¦ · Product Solutions YOUR MOST VALUABLE QA & DOSIMETRY TOOLS ... become part of a world-wide network of ... latest practices and

3D SCANNER™

Applications• TPS commissioning

• Linac acceptance

• Annual QA

Highlights• Patented cylindrical design scans on any axis

• Ring drive positions detector in any relevant 3D location

• Automated leveling and beam center positioning

• Built-in control box/electrometer

• Works with both diodes and ion chambers

Key Bene ts• 0.1 mm positioning accuracy

• Reproducible setup

• Less than 20 minute setup

• 65 cm scan range; no need for tank shift

The Cylindrical Advantage• Maintains ideal orientation of the detector during inline,

crossline and diagonal scans

• More scanning area - up to 65 cm in any direction

• Less volume means faster fill and drain time

• No need to shift the tank and risk setup inconsistencies

during shifting

• Water riples settle faster because of curved walls

AutoSetup™

• No more guess work, highly reproducible setup result.

• Ready to setup in less than 20 minutes

Vertical (mm): 400

Diameter (mm): 650

Ring (Degrees): 330

Motors: Encoded stepper/servo

Scanning Modes: Continuous and step

Scanning Speed Range (mm/sec): Variable up to 8

Scanning Accuracy (mm): 0.1 in all dimensions

Diameter inner, Height / Width (mm): 676 / 673 / 875

sunnuclear.com // SUN NUCLEAR CORPORATION | 31

3D MiniLift™

Highlights• Straddles linac couch ring for stability

• Fits through standard doorways

• Legs fold for compact storage

• Quick and easy disassembly or transport

Highlights• 187 L (49.5 gal) capacity

• Less than 6 minute fill time

• Less than 3 minute drain time

• Easily maneuverable

3D SCANNER Options

3D Reservoir™

Highlights• Supports Varian®, Elekta®, Siemens® and CyberKnife®

delivery systems

• Less than 5-minute installation with no additional tools

• 200 mm TPR drain measurement: 1.2 minutes

• 200 mm TPR fill measurement: 2.7 minutes

3D TPR™

Page 32: Product Solutions YOUR MOST VALUABLE QA & …€¦ · Product Solutions YOUR MOST VALUABLE QA & DOSIMETRY TOOLS ... become part of a world-wide network of ... latest practices and

1D SCANNER™

Applications• Detector positioning in water

• Output factors and dose calibrations

• Annual and routine QA

Highlights• Suitable for TG-51

• Automatic water level detection

Places the detector at the water surface

• Pendant and PC software control

• 30 cm scan depth

• Advanced scanning software option available

Key Bene ts• Fast and efficient detector positioning

• Accommodates all common electron cones

• Multi-function pendant

• Horizontal ruler for off-axis detector positioning

• Farmer type, universal, and reference detector

holders included

• Leveling platform available

Inner Dimensions (cm): 35 x 39 x 36

Inner Volume (cm): 48 liters at 34.5

Arm positioning Increments (cm): 0.01, 0.1, 1.0 & 10

Arm positioning Accuracy (cm): ± 0.01

Scan Depth Maximum (cm): 30

Tank Material: PMMA (Acrylic)

Weight Empty with Arm (kg): 10.9

Detector Type: SunPoint Diode Detectors

Quantity: 127

Spacing: (mm): 4

Overall Active Length (mm) 504

Active Volume (mm3): 0.019

Inherent Buildup Depth (mm): 8.1

Physical Buildup Depth (mm): 5.8

Sensitivity (nC/Gy): 32

1 I www.lightages.com32 | SUN NUCLEAR CORPORATION // sunnuclear.com

PRODUCT SOLUTIONS // Dosimetry

WaterProof PROFILER™

Applications• Scanning Dosimetry - relative dose measurements, acceptance

testing, TPS commissioning

• Open Fields and Electronic Wedges

Highlights• Single power/data cable connects directly to 3D SCANNER

• Oversampling feature provides accurate results

• Best specification detector spacing, count, and array length of

any water-proof array

• SunPoint Diode Detectors provide the sharpest penumbra for

the highest accuracy in beam modeling

• Calibration is fully automated and performed in the 3D

SCANNER with no need to go in and out of bunker

Key Bene ts• Speed – capture complete beam profiles instantly, and with a

fraction of the MU’s needed when using a single detector

• Accuracy – data is comparable to data collected when using a

single ion chamber

• Ease of use – attaches directly to 3D SCANNER in seconds

with no tools, warm-up, or external electrometer needed

3D SCANNER Options

Page 33: Product Solutions YOUR MOST VALUABLE QA & …€¦ · Product Solutions YOUR MOST VALUABLE QA & DOSIMETRY TOOLS ... become part of a world-wide network of ... latest practices and

PC Electrometer™ EDGE Detector™

Applications• SRS and IMRT beam modeling

• TPS commissioning

Highlights• Accurate penumbra characterization for all fields

• Ideal for steep dose gradients and small fields

• On Accuray® Recommended QA Equipment list

• 842 times smaller in volume than micro ion chambers

• 100 times more signal than micro ion chambers

Key Bene ts• No dose volume averaging

• Accuracy for critical penumbra measurements

• Works with all common water phantoms

Detector type: SunPoint® Diode Detector

Diode Die Location (mm):

0.3 from top

4.72 from end

2.7 from side

Indicated by cross hairs on top

of housing

Water Depth Equivalent (mm): 0.5

Housing Wall Thickness (mm): 0.13, brass

External Dimensions (mm): 3.8 x 5.5 x 38

Impedance: >200 Mohm at 10 mV reverse bias

Output Polarity: Negative

Cable: 3.4 mm dia. x 1.8 m long, triax

Connector: TNC or BNC

Charge (mCa): 2 pC – 10

Current Range Continuous (nA): 2 pA – 50

Current Range Pulsed (pC/pulse): 0 -105

Leakage (fA): < 10

A/D Converter: 16 bit

Non-Linearity: <+/- 0.1% of full scale

Long Term Stability: <+/- 0.5%

Measured Repeatability: <+/- 0.25% of full scale

Connector: TNC or BNC

Weight (kg): 0.4

Current Range Pulsed (pC/pulse): 0 -105

Applications• Reference class dosimetry for absolute dose calibration

• Mobility intensive assignments

Highlights• Lightweight and portable; weighs only 1 lbs

• USB powered — no batteries or power cord

• Intuitive user interface

• Fully configurable software interface

Key Bene ts• Pocket size, lightweight design

• Two independent measurement channels

• Interfaces with the 1D SCANNER

• Less than 1-minute warm-up time

• Single USB cable connection

• Fast sampling interval 500 ms

• Detector library

sunnuclear.com // SUN NUCLEAR CORPORATION | 33

Page 34: Product Solutions YOUR MOST VALUABLE QA & …€¦ · Product Solutions YOUR MOST VALUABLE QA & DOSIMETRY TOOLS ... become part of a world-wide network of ... latest practices and

SNC350p™ SNC125c™

Applications• Reference, field, and scanning dosimetry of electron beams

• TDD/TPS Commissioning and QA

Highlights• Conforms to the design principles as stated by Dr. M. Roos

• Meets AAPM TG-51 and IAEA TRS-398 requirements for

low-energy beams

• Reference dosimeter can be used to cross calibrate

field dosimeters

• Meets highest standards of performance (IEC 60731)

Key Bene ts• Well-guarded to reduce in-scattering perturbation effects

• Vented to provide air-density correction and eliminate need

for radioactive stability check device

• White chamber body allows easy visualization of the setup

relative to the crosshairs and lasers

Sensitive Volume (cm3): 0.388

Reference Point (mm): 1.07 Below Window Surface

Collection Volume Height (mm): 2.0

Collector Diameter (mm): 15.6

Guard Ring Width (mm): 4.1

Polarity Effect: Within 1.000 (±) 0.01

Max Dose Rate for (Gy/s):≥ 99.5 % Saturation≥ 99.0 % Saturation

5.2

10.4

Max Dose Per Pulse for (mGy):≥ 99.5 % Saturation≥ 99.0 % Saturation

0.46

0.92

Radiation Quality:Photons: 60Co to 25 MV

Electrons: 5 MeV to 25 MeV

Connector: TNC or BNC

Applications• Reference, Field, Scanning dosimetry of electron and

photon beams

• IMRT/VMAT Quality Assurance

Highlights• Intended for use in scanning, field and reference dosimetry

• Enhanced penumbra without loss of signal strength

Key Bene ts• Waterproof and fully guarded

• Vented to provide air-density correction and eliminate the

need for radioactive stability check device

• White chamber body gives a clear line of sight to the

crosshairs and lasers during set up and set up verification

Active Volume (cm3): 0.108

Active Length (mm): 7.05

Active Diameter (mm): 4.75

Sensitivity (nC/Gy): 3.4

Wall Material (mm):Paint 0.05

PMMA 0.30

Graphite 0.25

Electrode (mm): 0.8 diameter aluminum

Vented:To atmosphere through

waterproof tubing

Waterproofi ng: Viton Tubing

Polarizing Voltage: ±400V Max

Cable Length (m): 1.5

Cable Connector: TNC or BNC

1 I www.lightages.com34 | SUN NUCLEAR CORPORATION // sunnuclear.com

PRODUCT SOLUTIONS // Dosimetry

Page 35: Product Solutions YOUR MOST VALUABLE QA & …€¦ · Product Solutions YOUR MOST VALUABLE QA & DOSIMETRY TOOLS ... become part of a world-wide network of ... latest practices and

Active Volume (cm3): 0.6

Active Length (mm): 22.7

Active Diameter (mm): 6.1

Sensitivity (nC/Gy): 20

Wall Material (mm): Paint 0.05, Graphite 0.43

Electrode (mm): 1.1 diameter aluminum

Vented:To atmosphere through

waterproof tubing

Buildup Cap (mm): 4.5

Polarizing Voltage: ±400V Max

Cable Length (m): 1.5

Cable Connector: TNC or BNC

“The tank setup is by far the easiest setup of a scanning tank I have ever used and a testament to the ground up approach to the engineering of this scanning system. From my experience with D SCANNER, I’ll be a Sun Nuclear tank user for all of my future sites.

Mike Tallhamer, M.ScChief of Physics

Centura Health, Colorado, USA

sunnuclear.com // SUN NUCLEAR CORPORATION | 35

3D SCANNER™SNC600c™

Applications• Photon and electron dosimetry

• Reference dosimetry - treatment delivery device calibration,

cross calibration of other ionization chambers

• Field dosimetry - output stability checks for QA

• Scanning dosimetry - relative dose measurements, acceptance

testing, treatment planning system commissioning

Highlights• Reference class ionization chamber (IEC 60731)

• Follows industry classic Farmer chamber design

• Fully guarded

• Vented

• Waterproof

• White thimble provides cross hair contrast

• Rotational orientation indicator mark

• Included Co-60 cap allows for air KERMA calibration

Key Bene ts• Compatiability for existing Farmer chamber phantoms due to

classic Farmer chamber design

• Highest performance for reference dosimetry

• Improved setup and accuracy from white chamber body gives

a clear line of sight to the crosshairs and lasers during set up

and set up verification

Page 36: Product Solutions YOUR MOST VALUABLE QA & …€¦ · Product Solutions YOUR MOST VALUABLE QA & DOSIMETRY TOOLS ... become part of a world-wide network of ... latest practices and

ProSol_B040715©2015 Sun Nuclear Corporation. All Rights Reserved. All data used is best available at time of publication. Data is subject to change without notice.

T +31 (0)24 648 86 88

Nederland België / Belgique

T +32 (0)3 309 32 09 [email protected]