Product Solutions
YOUR MOST VALUABLE QA & DOSIMETRY TOOLS
T +31 (0)24 648 86 88
Nederland België / Belgique
T +32 (0)3 309 32 09 [email protected]
1 I www.lightages.com2 | SUN NUCLEAR CORPORATION // sunnuclear.com
Better Outcomes Through Technology .............................................5Innovation That Improves Outcomes While Saving Time..................6Total Solution Partner for Product Training & Support ................8 -11
ArcCHECK® ................................... 13MultiPlugTM .................................... 13CavityPlugTM .................................. 133DVH®............................................ 14Respiratory MotionSimTM ............... 14PlanIQTM ......................................... 15PerFRACTIONTM 2D & 3D .............. 15EPIDoseTM ...................................... 16MapCHECK® 2 .............................. 16MapPHANTM .................................. 17IVDTM 2 / rf-IVDTM 2 ........................ 18IsoRadTM ........................................ 18QEDTM ............................................ 18
Contents
PRODUCT SOLUTIONS // Table of Contents
sunnuclear.com // SUN NUCLEAR CORPORATION | 3
ATLASTM ......................................... 21Daily QATM 3 / rf-Daily QATM 3 ........ 21CHECKMATETM 2 ........................... 22
StereoPHANTM ............................... 25IC PROFILERTM .............................. 26PROFILERTM 2 ............................... 26TomoDoseTM .................................. 27SRS PROFILERTM .......................... 27IMFTM / GMFTM ............................... 28SNC MachineTM ............................. 28
3D SCANNERTM ............................. 313D MiniLiftTM .................................. 313D ReservoirTM ............................... 313D TPRTM ....................................... 31WaterProof PROFILERTM ............... 321D SCANNERTM ............................. 32PC ElectrometerTM ......................... 33EDGE DetectorTM ........................... 33SNC350pTM .................................... 34SNC125cTM .................................... 34SNC600cTM .................................... 35
1 I www.lightages.com4 | SUN NUCLEAR CORPORATION // sunnuclear.com
PRODUCT SOLUTIONS // Introduction
Independent and relevant quality assurance is more important than ever. Choosing a partner with a record of clinically-proven solutions and a history
of outstanding quality and service is just as important.
Sun Nuclear deals with the challenges confronting
every Radiation Oncology program: safe and
effective delivery of the intended prescriptions
and doses to patients. These challenges have
implications including:
• Patient Safety
• Patient Clinical Outcomes
• Facility Continual Improvement
• Facility Employee Satisfaction
• Facility Reputation for Quality
• Facility and Employee Accreditations/
Certifications
• Facility Financial Health
In choosing Sun Nuclear, you gain a partner with
more than 30 years of proven experience and you
become part of a world-wide network of cancer
treatment facilities committed to improving QA and
Dosimetry outcomes.
Resource Depth
Headquarter facilities and manufacturing are in
Melbourne, Florida, USA
2 linacs with photons, electrons, MLC, and EPID
1 Cobalt 60 teletherapy system
5 treatment planning and oncology information
systems
Better Outcomes
THROUGH TECHNOLOGY
MEDICAL PHYSICS | NUCLEAR MEDICINE | RADON MONITORING
sunnuclear.com // SUN NUCLEAR CORPORATION | 5
1 I www.lightages.com6 | SUN NUCLEAR CORPORATION // sunnuclear.com
Innovation that
IMPROVES OUTCOMES WHILE SAVING YOU TIME.Many companies claim to develop innovative products, but their products are not better or different than any other product. Our solutions are designed for you and the way you work, not the other way around. The result? Solutions that look and perform differently in a way that improves outcomes while saving you time.
PRODUCT SOLUTIONS // Innovation
The Right Detector for the Right ApplicationSun Nuclear manufactures both diode and ion chamber
detectors and arrays. Sun Nuclear’s SunPoint Diode
Detectors offer the benefit of a smaller active area,
better sensitivity, less drift and increased lifetime.
SunPoint Diode Detectors are used for small field/
patient-specific applications due to smaller size and
better performance characteristics for small and
modulated fields.
Ion chambers are used for large field/low-modulation
applications where small size is not necessary. Sun
Nuclear software also supports EPID, Gafchromic film,
and CR detectors.
Quick and Easy Setup
• Patented user calibration (Wide Field Calibration)
• USB communication with PC
• Single unit, lightweight designs
• Single cable for power and data
• No warm-up or pre-irradiation required
• Intuitive software for short learning curve
Independent
• Checks and balances using diodes, ion chambers,
EPIDs, and log files
• Independent from delivery and planning systems
• Measurement, and measurement-based calculations
• Not 100% reliant on calculation-only patient QA
Data Integrity and Transparency
• Original raw and processed data available to user
• Data export to spreadsheets
• Independently analyze any measurement data
• All algorithms documented in online help
Industry FirstsFirst Plan Quality Analysis Using Quantified Metrics
c. 2015, Quality Reports™
First Dose on patient geometry without a TPS dose
calculation c. 2010, 3DVH®
First EPID-based dose analysis for patient-specific IMRT
QA c. 2007, EPIDose™
First Patient-specific respiratory and gating simulation
system c. 2005, MotionSim™
First Electronic 2D Array for patient specific IMRT QA
c. 2002, MapCHECK®
First Daily QA trending database c. 1996, Daily QA™ Check
Corporate Partnerships
sunnuclear.com // SUN NUCLEAR CORPORATION | 7
LEADER - Sun Nuclear #1Worldwide Market Share
Leader for Quality and Safety
4,000 Worldwide Cancer Treatment Facilities Use Sun Nuclear Solutions
60 Countries with Sun Nuclear Solutions
90% of U.S. Cancer Centers Use Sun Nuclear Products
Sun Nuclear Training Center in Melbourne, FL,
4 Continents with Full-time Sun Nuclear Support Teams: Europe,
Asia, South America, North America
15 AAPM Task GroupMemberships
1 I www.lightages.com8 | SUN NUCLEAR CORPORATION // sunnuclear.com
At Sun Nuclear we know
THE VALUE OF EDUCATIONOngoing education is an important component of a successful continual improvement program, which ultimately helps to improve outcomes and patient safety. Sun Nuclear is a leader in the sharing of information and ideas from both industry and clinical perspectives. Our educational activities focus on both product and task-speci c subjects as well as broader issues in the radiation oncology industry.
PRODUCT SOLUTIONS // Training and Education
Live Product WebinarsSun Nuclear hosts live educational Product Webinars as part of its educational program. The webinars are hosted online, and are presented by clinical users and product experts. All webinars last approximately 30 minutes, with a live Q&A session following the webinar. Visit us online to register for our upcoming webinars. CE credits are available for select webinars. Register at sunnuclear.com/webinars.
Exploring the Future of QA and DosimetryThe QA & Dosimetry Symposium (QADS) is the only event for Medical Physicists and Dosimetrists that brings leading clinical innovators together to discuss the latest practices and issues related to QA and Dosimetry in Radiation Oncology. The symposium provides attendees with practical guidance from industry experts on new and relevant products, processes, and techniques in today’s evolving Radiation Oncology environment. The talk schedule is supplemented by opportunities to interact with leading industry vendors and colleagues in both professional and social settings. Register at qasymposium.com
Benefits• Continuing education credits (CAMPEP, SAM, and MDCB)
• Presentations from the industry’s leading authorities on the latest practices and
future direction of Radiation Oncology QA and Dosimetry
• Major vendor participation
• Leading resort venues
• Free registration for students and residents
• Web access to presentations after the symposium
• Networking with peers
sunnuclear.com // SUN NUCLEAR CORPORATION | 9
& DosimetrySYMPOSIUMExploring the future of QA and Dosimetry
The Sun Nuclear Training Center opened its doors in 2013. The training center is purpose-built, demonstrating Sun Nuclear’s commitment to patient safety and the effective use of QA solutions.
Users can experience in-depth exploration of Sun Nuclear product functionality on a linac, as well as application-specific coursework such as IMRT QA, VMAT QA, Annual QA, and Commissioning. The training center offers this training in an environment that closely mimics an actual clinical setting for a realistic learning experience.
Training courses on a variety of subjects are offered year round and are delivered by Sun Nuclear subject matter experts and experienced clinical users. Details on upcoming training courses are posted on the Sun Nuclear Support website.
Quality Content
Hands-on Learning
Why the Sun Nuclear
Peer-to-Peer Instruction
State-of-the-Art FacilityTake a virtural tour of the Training Center at sunnuclear.com/training
1 I www.lightages.com10 | SUN NUCLEAR CORPORATION // sunnuclear.com
Total Solution Partner for
PRODUCT TRAINING & SUPPORTWe are committed to providing customers with the best possible support experience. Sun Nuclear’s Support team includes over twenty professionals with diverse physics, teaching, engineering, customer support, and language skills. As always, Sun Nuclear customers receive complimentary standard technical support, and there is never a limit to the number of times you may contact us with a question.
PRODUCT SOLUTIONS // Training and Education
Training Matrix On-site Online In-house On-site Online In-house
Trained Sun Nuclear professional on site Y - Y Remote assistance with installation of software Y Y -
Comprehensive syllabus Y Y Y Assist with acquisition of sample measurements Y - Y
Provides users with in-depth and effi cient
product use experienceY Y Y Train users on comprehensive product functionality Y Y Y
Training on advanced features Y Y Y Question and answer (Q&A) session Y Y Y
Training on real-time operation of the software Y Y Y Maximize benefi ts of the product(s) purchased Y Y Y
Secure Internet connection with unlimited
customer attendeesY Y -
Shorten learning curve and begin using
product(s) sooner Y Y Y
Oversee and physically assist with installation of
devices and softwareY - Y
Product TrainingAll Sun Nuclear products are designed for easy installation and setup. As an added service, Sun Nuclear o ers professional product installation and training for all products. Customers have three options to choose from:
Option 1: On-site Installation and Training
Option 2: Online Product Training
Option 3: In-house Product Training at the Sun Nuclear Training Center
Worldwide: Standard Sun Nuclear telephone support is o ered from 8am to 8pm ET, Monday through Friday.
Regional: Standard extended regional telephone support hours are available.
After hours/on-call telephone support options are available.
Secure Remote SupportSun Nuclear users who have a current maintenance contract may request live online assistance.
Online assistance allows trained Sun Nuclear support professionals to collaborate directly in the user’s PC environment to evaluate and resolve issues, relieving the user of this task.
Sun Nuclear Support Website which provides the following bene ts:
• Access to software, manuals, and software license keys in
real time for your products.
• Exclusive instructional material including videos and FAQs.
• Sun Nuclear account management (inventory of products
and product details).
• Ability to request information and support.
Visit sunnuclear.com/support
sunnuclear.com // SUN NUCLEAR CORPORATION | 11
Telephone Sun Nuclear Support SiteAll Sun Nuclear users have access to an exclusive, user-only
Sophisticated treatment options such as Arc, Helical, IGRT, IMRT, and SRS demand equally sophisticated patient specific QA. Modern patient plans are often collections of small beamlets with very steep dose gradients.
Since these dose gradients are too tightly to conform to patient anatomy and PTV accurate veri cation of the dose gradient is critical. Using the right technology is critical. Sun Nuclear o ers a variety of sophisticated treatment options using our advanced
diode detectors, which measure actual delivered dose without the misleading and often hidden e ects of dose volume averaging as seen in ionization chambers.
Sophisticated Treatment Options Demand
PATIENT SPECIFIC QA
1 I www.lightages.com12 | SUN NUCLEAR CORPORATION // sunnuclear.com
PRODUCT SOLUTIONS // Patient QA
Cavity Options
Applications• Patient plan QA
RapidArc®/VMAT, FFF, SmartArc and TomoTherapy®
Routine IMRT and 3D conformal
• Machine and setup QA
Highlights• The world’s first true 4D detector array
• The world’s first cylindrical detector array
• The world’s first electronic array designed specifically for
rotational dosimetry
ey Bene ts• Utilizes SunPoint® Diode Detectors
• Consistent BEV regardless of gantry angle
• High detector density in BEV
• 221 detectors in central 10 x 10 cm
• Easy setup and lightweight (16 kg)
• Measure both composite and per control point
• Real-time updates (50 ms)
Detector Type: SunPoint Diode Detectors
Detector Quantity: 1386
Detector Spacing (cm): 1.0
Array Diameter (cm): 21.0
Inherent Buildup (g/cm2): 3.3 +/- 0.1
Inherent Backscatter (g/cm2): 3.3 +/- 0.1
Array Geometry: Helical Grid, 1 cm offset
Phantom Material: PMMA (Acrylic)
Weight (kg): 16
Applications• IMRT, Arc, SRS, SBRT dose distributions in cavity
• Supports 3DVH®
Highlights• Precision fitted for ArcCHECK central cavity
• Accepts ion chambers, diodes, film detectors
• Position single detectors in any of 25 unique locations
• Position film sizes up to 13 x 21 cm in X or Y axis
• Angle indicator allows rotation to any angle within
ArcCHECK cavity
Applications• Measures dose at isocenter
• Supports 3DVH
sunnuclear.com // SUN NUCLEAR CORPORATION | 13
ArcCHECK®
MultiPlug™
CavityPlug™
Supports Coplanar & Non-Coplanar Beams: Yes
Estimation of Absolute Patient Dose: Yes
Analysis by Patient DVH: Yes
Accounts for TPS error: Yes
Accounts for Beam Delivery Error: Yes
Statistics per Anatomical Structure: Yes
DICOM RT Compatibility: Full integration
VMAT and RapidArc® Support: Yes
Analysis of Beam by Beam Errors: Yes
Applications• 3D or 4D patient dose QA using ArcCHECK®,
MapCHECK® 2, EPIDose™, or Film
• IMRT, VMAT, and Conventional Patient QA
• Effective tool for commissioning
• Coplanar and non-coplanar deliveries
Highlights• Create an estimated 3D or 4D patient dose volume for QA
• Structure-based analysis tools
• Intuitive and powerful user interface
• Generate easy-to-read QA reports
• Create high density, high resolution dose reconstruction in
ArcCHECK volume with Virtual Gel™
• Evaluate the effects of structure motion on estimated
patient dose distribution with optional Respiratory
MotionSim
ey Bene ts• Clinically relevant patient QA
• Eliminates dose to phantom guesswork
• No commissioning required
Applications• Respiratory dosimetric effects simulation
• Prostate and other non-cyclical motion simulation
• Gating dosimetric effects simulation
• IMRT, VMAT, and Conventional Patient QA
Highlights• Quantify and visualize the effects of structure motion on
the estimated patient dose distribution, including DVH
• Patient-specific respiratory patterns imported from 4DCT -
manual entry of trajectory data not required
• Interplay effect simulation - averages possible interplay
effects over multiple fractions
• Track individual voxels as a function of time
• Movie mode features 4D playback of dose accumulation,
motion, and time
• Customize moving target, margin, direction of motion,
one-time/repeating motion, etc.
ey Bene ts• Allows quantification of patient-specific motion effects
on 3D dose distribution in patient anatomy
• No additional setup or phantom required
• Motion effects are fully patient specific
• Dose distributions in patient anatomy and geometry
• No commissioning
• Fully integrated with 3DVH
1 I www.lightages.com14 | SUN NUCLEAR CORPORATION // sunnuclear.com
3DVH®
Respiratory MotionSim™
3DVH Options
PRODUCT SOLUTIONS // Patient QA
Meets Reimbursement Requirements: Yes
Supports all Treatment Modalities: Yes
Independent Check: Yes
Access From any Computer on Network: Yes
Detects Patient Setup Errors: Yes
Detects Patient Anatomy Changes: Yes
Detects Output Fluctuations: Yes
Detects Machine MLC, Jaws/Collimator Errors: Yes
Commissioning Required: No
Browser Support: Chrome, IE8, IE9
Applications• Fraction 0: Pre-Treatment IMRT QA without a phantom (3D)
• Fraction n: Treatment delivery QA for every fraction (2D & 3D)
Highlights• Completely automated workflow captures and analyzes all
necessary files and emails if a failure - no further work required
• 2D planar comparison to baseline and/or predicted images
• 3D dose reconstruction on patient CT using proprietary
collapsed cone convolution superposition algorithm (3D)
• Point dose and region of interest calculations (3D)
• Clinical goals pass/fail calculation (3D)
• AutoCalTM - automated EPID response calibration feature
corrects for EPID drift
• Included SNC Server streamlines installation
• Web-browser access from any computer on your network
• Works with Varian, Elekta, Aria, Mosaiq
ey Bene ts• Consistent system for both pre-treatment QA (Fraction 0)
and per-fraction QA (Fraction n)
• Complete automation - no additional time requirements -simply
approve results when ready
• Detects the most common types of errors - patient errors - as
well as machine errors
• EPID-based Measurement QA solution maintains
independence and billing compliance (US)
sunnuclear.com // SUN NUCLEAR CORPORATION | 15
PerFRACTION™ 2D & 3DPlanIQ™
Applications• Clinical goal feasibility and plan optimization
• Plan quality scorecards and improvement
• Commission auto-treatment planning systems
• Plan documentation
Highlights• Determine feasibility of the clinical goals before planning begins
• Optimize clinical goals with Feasibility DVH which show what
DVH are feasbile for each target and OAR
• Plan Quality Metrics (PQM and APQM) provide patient specific
plan quality scoring, for entire plan and for each target and OAR
• Choose from over 70 pre-defined quality protocols to score
against and customize
• Single comprehensive report for complete patient treatment
plan and quality scoring for compliance
• DVH QA to support TG-53 compliance
• Record patient quality metrics to quality library, and
demonstrate continual improvmeent
ey Bene ts• No time wasted on treatment planning of ambiguous or
unachievable goals
• Higher quality treatment plans
• Easier compliance with documentation and quality
requirements
More than simple pass/fail of objectives: Yes
Takes into account patient specifi c challenges: Yes
Drives continuous improvement: Yes
Compatible with all TP and R&V Systems: Yes
Supports all Treatment Modalities: Yes
Vendor-Neutral DVH QA: Yes
Dedicated DICOM Server: Yes
Compatible with 3DVH®: Yes
Interactive visualization of DICOM Data: Yes
Customizable Reports: Yes
Applications• Quick conversion of MV EPID images to absolute dose
• Absolute Dose Commissioning using MapCHECK® 2
Highlights• EPID based patient plan QA
MV EPID images to absolute
Comparison, subtraction, overlay, profiles
Rotational delivery support
• Supports all delivery modalities and linacs
Any EPID distance or dose plane setup
• Independent of treatment planning system and linac
Patented algorithm tests TPS calculations - Catch errors
missed by image QA
Use with 3DVH® software
ey Bene ts• Easy to Use
No buildup on EPID
Combine split fields
Maximize the benefits of MV EPID
• Absolute Dose Commissioning using MapCHECK® 2
• Corrections of per segment output factor variation and
phantom scatter
Independent Dose Comparisons: Yes
Increased Data Density for QA: Yes
Audit the TPS and Delivery System: Yes
No Buildup on EPID: Yes
Measure at Any Gantry Angle: Yes
One Model Works with Each:
Linac/EPID
Photon energy
Source to EPID
Source to Dose plane
Dose plane depth
1 I www.lightages.com16 | SUN NUCLEAR CORPORATION // sunnuclear.com
EPIDose™
Applications• Patient plan QA
IMRT QA
RapidArc®/VMAT, FFF and TomoTherapy®
(with accessories)
• Machine, MLC, and setup QA
Highlights• Most detectors of any 2D array
• Highest detector density of any 2D array
• Largest field size of any 2D array
• MapCHECK 2 is a turn-key solution
ey Bene ts• Proven solution for film-less rotational and IMRT delivery
• Utilizes SunPoint® Diode Detectors
• Easy to use and efficient software
• Single click comparisons
• Rotational capable when used with MapPHAN option
• Real-time updates (50 ms)
• Interfaces with the IMF™
Detector Type: SunPoint Diode Detectors
Detector Quantity: 1527
Detector Spacing (mm): 7.07
Array Size (cm): 32.0 x 26.0
Inherent Buildup (g/cm2): 2.0 ± 0.1
Inherent Backscatter (g/cm2): 2.7 ± 0.1
Array Geometry (cm):Detector spacing parallel
to X and Y axes: 1.0
Row spacing: 0.5
Phantom Material: PMMA (Acrylic)
Weight (kg): 7.1
MapCHECK®2
PRODUCT SOLUTIONS // Patient QA
Applications• Patient plan QA for rotational delivery
RapidArc®/VMAT, FFF and TomoTherapy®
Coronal and sagittal orientation
Construction: Virtual WaterTM
Available Depths (cm): 5.0 cm, 10.0
Area (cm2): 35.0 x 38.0
Weight (kg): 8.0 (5 cm), 21.0 (10 cm)
sunnuclear.com // SUN NUCLEAR CORPORATION | 17
MapPHAN™
MapCHECK 2 Options
PerFRACTION™
“Over the duration of the study, multiple MLC positional errors were detected using the EPID based software but these same errors were not detected using the trajectory log les.
“Monitoring daily MLC positional errors using trajectory log les and EPID
measurements for IMRT and MAT deliveries, A. Agnew, et al., 2014 Phys. Med. Biol. 59 N49
Highlights• Flat design for easy placement on patient
• Accurate and stable SunPoint Diode Detector
ey Bene ts• Real-time dose reading
Highlights• Cylindrical design for isotropic response
• Accurate and stable SunPoint® Diode Detector
ey Bene ts• Real-time dose reading
15-2
5 MV
1-4 M
V
6-12
MV
1-4MV
6-12
MV
15-25
MV
ELECTR
ON
SKINDetector Area (mm2): 1.54
Active Dimension (mm): 1.4 diameter
Dose Rate Dependence (cm): ± 1%, 75 - 250 SSD
Detector Sensitivity (nC/Gy): 27
Detector Stability: 0.5% /kGy at 6 MV
Detector Area (mm2): 0.64
Active Dimension (mm): 0.8 x 0.8
Dose Rate Dependence (cm): ± 1%, 75 - 250 SSD
Detector Sensitivity (nC/Gy): 32
Detector Stability: 0.5% /kGy at 6 MV
1 I www.lightages.com18 | SUN NUCLEAR CORPORATION // sunnuclear.com
ISORAD™ DetectorIVD™ 2 rf-IVD™ 2/
QED™ Detector
Applications• Dose verification during treatment
• Final check of complete system
• Total Body Irradiation (TBI)
Highlights• Real-time wireless option available (rf-IVD 2)
• Use with control module or PC software
• Expandable to 52 channels, 4 channels standard
• Record and verify interface
ey Bene ts• Simple to install and easy to use
• Automatic patient temperature compensation
• 12 calibration keys
• Patient database
• Correction factor tools
• Accuracy and reliability proven worldwide
• Use with industry standard re-usable detector options
QED - Flat for easy patient placement
ISORAD - Cylindrical for isotropic response
Channels:Standard: 4
Maximum: 52
Temperature Compensation:
Automatic-within 0.10 C
(Negative polarity only)
Repeatability (cGy): ± 0.2% or ± 0.1
Polarity:Bipolar (negative or positive
polarity detectors)
Leakage: Automatic compensation
Warm-Up Time: < 30 sec
Power:rf-IVD 2 : Rechargeable NiMH
battery (12 hr)
IVD 2 : Power supply
Weight (kg): 0.34
PRODUCT SOLUTIONS // Patient QA
sunnuclear.com // SUN NUCLEAR CORPORATION | 19
“We are using the ArcCHECK for about a year now for QA of our clinical IMRT plans. On the basis of our experiences we can conclude that the ArcCHECK is not only suitable for the QA of Elekta linacs, but also for small stereotactic elds up to x cm2) from a
Novalis® linac Brainlab).
Dr. Paul Rietveld, Ph.D.Radiotherapiecentrum, The Netherlands
ArcCHECK®
Routine daily, monthly, and annual tests are prescribed as part of a robust QA and Dosimetry program. For the person taking the routine measurement, tools must be easy to use and reliable.
The physics goal of routine QA is to maximize the data integrity and analysis options. Sun Nuclear is the only company to achieve this goal by o ering a daily device with 25 detectors that performs ve uni ue tests in a single measurement. This goal is
carried a signi cant step further with ATLAS, which centralizes all routine QA and Dosimetry test data in one location, o ering new opportunities in reporting, analysis, and e ciency.
Maximize Data Integrity and
ANALYSIS OPTIONS
1 I www.lightages.com20 | SUN NUCLEAR CORPORATION // sunnuclear.com
PRODUCT SOLUTIONS // Routine
ATLAS™
Applications• Radiotherapy center QA management
• Scheduling, equipment, and messaging management
Highlights• A front end for data acquisition
• A back end for reporting and analysis
• Suitable for both small and large facilities
• Upload documents to the Attachment Center
• Audit Log shows overdue/failed test
Searches Attachment Center for documents that have
expired or are about to expire
Tests can be cloned either as a group or individually to a
new machine
ey Bene ts• Integrated test libraries
• Customizable tests
• Resource tracking management
• Facility and user management
• Attachments
• TG-142 and TG-51 libraries
Organization Structure:Daily, monthly, annual, dosimetry,
mechanical, safety, and imaging
Test Libraries:TG-40, TG-142, TG-51
Manufacturer recommended
Customize Tests: Yes
Resource Tracking: Yes
User Management: Yes
Communication Center: Yes
Data Management: Yes
Networkable: Yes
Applications• Daily linac monitoring and trending
Output, flatness, symmetry, energy, light-radiation
field coincidence
• Rotational delivery supported
Highlights• Utilizes both ion chambers and diodes for optimal results
• Measure output, flatness, symmetry, field size, energy in a
single exposure
• Trend analysis database software included
• No warm-up or pre-irradiation required
• Real-time wireless available (rf-Daily QA 3)
ey Bene ts• No buildup or flipping required
• Automatic temperature and pressure correction
• Real-time measurements
• Simple two-step operation
Start and then Record
Interfaces with the IMF™
Detector Type:Sun Point® Diode Detectors
Vented Ion Chambers
Detector Quantity:Diodes: 12 total
Chambers: 13 total
Detector Spacing (mm): Diodes: 5
Chamber Active Value (cm3): Electron: 0.6; Photon: 0.3
Inherent Buildup (g/cm2): Chambers: 1.0 ± 0.1
Inherent Backscatter (cm): 2.3
Field Size (cm): 20 x 20
Weight (kg): 5.7
Daily QA™ 3 / rf-Daily QA™3
sunnuclear.com // SUN NUCLEAR CORPORATION | 21
Detector Type: Vented Ion Chamber
Detector Quantity: 1 - CAX
Parallel Plate Separation (mm): 4.0
Field Sizes (cm): 10 x 10 and 20 x 20
Detector Volume (cm3): 0.6
Inherent Buildup (g/cm2): 1.0 ± 0.1
Inherent Backscatter (cm): PMMA, 2.3
Weight (kg): 4.9
CHECKMATE™ 2
1 I www.lightages.com22 | SUN NUCLEAR CORPORATION // sunnuclear.com
PRODUCT SOLUTIONS // Routine
Applications• Daily central axis output
• Repeatability
• Monitor chamber linearity
Highlights• Built-in rechargeable batteries
• Precision alignment template
• User calibration
• Stores up to 15 calibration values
Automatic memory position advance
ey Bene ts• Cost effective solution
• Simple to use
• Automatic temperature and pressure correction
Large, easy to read display
sunnuclear.com // SUN NUCLEAR CORPORATION | 23
“The chamber to chamber variation, combined with the IC PROFILER™ 2D array’s calibration stability with time feature has been proven to be suf ciently stable for the device to be used to signature water phantom performance in line with Elekta’s manufacturing needs.
Craig HuntServices Product Specialist
Oncology Services DevelopmentElekta Ltd.
IC PROFILER™
Machine QA should be performed with three primary goals in mind. The first is to foresee an issue before it occurs; the second is to identify an issue as soon as it is measureable; and the third is to apply prior understanding to improve the machine output and stability, and the overall QA program. Many of these goals are re ected in international QA guidelines, and many are easily and accurately accomplished using Sun Nuclear’s line of Machine QA tools. Since the introduction of the PROFILER in 1996, through PROFILER 2,
TomoDose, SRS PROFILER, StereoPHAN, IC PROFILER, and SNC Machine, Sun Nuclear is committed to meeting and exceeding the goals of Machine QA regardless of the challenge or delivery modality.
Improve Machine Output
STABILITY AND OVERALL QA
1 I www.lightages.com24 | SUN NUCLEAR CORPORATION // sunnuclear.com
PRODUCT SOLUTIONS // Machine QA
Applications• Brainlab®
• Fraxion® GammaKnife®
• CyberKnife®
StereoPHAN™
Applications• Stereotactic (SRS/SRT/SBRT) end-to-end testing
• Quality assurance of image fusion algorithms for CT and
MRI imaging modalities
• Absolute, relative and point dose dosimetry QA
measurements at isocenter with ion chambers; relative
dose distribution using film
Highlights• Consistent orientation allows for interference-free dose
measurement regardless of measurement plane
• Target volumes in CT/MRI cube eliminate need for
CT/MRI markers
• Flat surface of ion chamber cube geometry enables easy
cross-calibration to water
• Support for stereotactic frame and frameless systems
Key Benefits
• Phantom stand holds the inserts, making them easily
accessible during testing
• Multi-functional cube inserts increase efficiency
• No tools required for assembly
• Stand base can be mounted to a couch that uses the
Lok-Bar™ system
• All components fit into durable rolling case suitable for
storage and travel
Material: PMMA (Acrylic)
Weight (Including all Inserts) (kg): 11.1
Measurement Cubes (mm): 85 x 85 x 85
StereoPHAN Dimensions (mm): 518 x 276 x 323
sunnuclear.com // SUN NUCLEAR CORPORATION | 25
Film CT Ion Chamber
Film Ion chamber
StereoPHAN Options
SRS/SBRT Headframes
CT/MRI
MRI Signal
Generator
Universal Spacer
StereoPHAN Inserts
CyberKnife® Support
Applications• Alternative to a water phantom for many tests
Flatness, symmetry, field size, beam center, penumbra
width, light-radiation field coincidence
• Real-time beam constancy, steering, diagnostics
• Evaluate collimator and rotational sag
• Profile comparison, subtraction, and overlay
Identify startup/time dependent anomalies
Highlights• Quick and precise beam QA measurement
• Sets up in minutes versus hours for a typical water tank
• Multiple real-time parameter calculations
• No warm-up or pre-irradiation required
• Import water tank data and compare to PROFILER files
Key Bene ts• Real-time beam measurements
• Fast and efficient setup
• One measurement checks multiple parameters
• Interfaces with the IMF™
Detector Type: SunPoint® Diode Detectors
Detector Quantity: 139 Total: X Axis: 57 / Y Axis: 83
Detector Spacing (mm): 4
Array Size (cm): 22.4 x 32.8
Inherent Buildup (g/cm2): 1.0
Inherent Backscatter (g/cm2): 2.0
Phantom Material: Virtual Water™ top plate
Weight (kg): 5.0
1 I www.lightages.com26 | SUN NUCLEAR CORPORATION // sunnuclear.com
PROFILER™ 2
PRODUCT SOLUTIONS // Machine QA
IC PROFILER™
Applications• Full field measurement instead of a single point
• Beam constancy, steering, diagnostics
• Comprehensive linac QA
Highlights• With appropriate calibration, the IC PROFILER has an
accuracy within 0.5% of a water tank
• Unique curved ion chamber design maximizes signal
and minimizes volume averaging
• Very low noise to signal ratio (0.15%)
Key Bene ts• 45 cm length diagonals
• 0 x 40 cm field measurement at 75 cm SDD
• Maximum dose rate of 6660 cGy/min
Detector Type: Parallel plate Ion Chamber
Detector Quantity:251 Total: X Axis: 63 / Y Axis: 65
-Diagonal: 63 / +Diagonal: 63
Detector Spacing (mm): 5.0
Array Size (cm): 32.0 x 32.0
Detector Volume (cm3): 0.046
Detector Sensitivity (pC/cGy): 14.4
Inherent Buildup (g/cm2): 0.9
Inherent Backscatter (g/cm2): 2.3
Phantom Material: PMMA (Acrylic) / PC
Weight (kg): 8.8
Applications• Use for Machine QA on TomoTherapy® Hi-Art®
• Post component replacement verification
• Daily QA tests
Highlights• Only array designed for TomoTherapy Hi-Art
• Measure entire Hi-Art beam in a single measurement
• Accessibility to raw data
• Import water tank data and compare to TomoDose files
Key Bene ts• Fast and efficient setup
• Ten measurement axes for both X and Y direction
• Measure output, symmetry, flatness, field size, penumbra,
beam center
• Analyze and compare up to 15 profiles at once
• Instantaneous dose rate plot
Detector Type: SunPoint Diode Detectors
Detector Quantity: 223 total on X and Y
Detector Spacing (mm): X: 5.0, Y: 4.0, Y Off-axis: 8.
Array Size (cm): 53.0 x 9.8
Array Geometry (cm): X: 53.0 Y: 9.8 (8.0 at ±19.0)
Inherent Buildup (g/cm2): 1.0
Inherent Backscatter (g/cm2): 2.8
Phantom Material: PMMA (Acrylic)
Weight (kg): 5.0
Applications• SRS cone based radiation therapy
On Accuray® Recommended QA Equipment list
• Daily, monthly, and annual machine QA
Highlights• Array is designed for cone based SRS
• Accepted and proven for clinical and factory settings
• Import water tank data and compare to PROFILER files
• Real-time analysis
Key Bene ts• Fast and efficient setup
• Identify startup/time dependent anomalies
• One measurement checks multiple parameters
• Attaches to the CyberKnife® birdcage
Detector Type: SunPoint® Diode Detectors
Detector Quantity: 125 total on four axes
Detector Spacing (mm): 4
Radial Field Size (mm): 10, 20, 40, 60, 80, 100, and 120
Axes Length (mm): 143 (X), 127 (Y), 124 (Diagonals)
Inherent Buildup (g/cm2): 0.5
Phantom Material: PMMA (Acrylic)
Weight (kg): 1.5
sunnuclear.com // SUN NUCLEAR CORPORATION | 27
SRS PROFILER™TomoDose™
Applications• TG-142 imaging and mechanical QA
• VMAT mechanical and dosimetric QA
Highlights• Comprehensive pre-defined test library for TG-142 and VMAT QA
• Completely automated workflow captures and analyzes all
necessary files - no further work required
• Easy phantom baseline setup with automatic ROI registration
• Trend any test or test parameter against any other test or test
parameter for any number of machines
• Included SNC Server streamlines installation
• Supports most common imaging and mechanical QA
phantoms for TG-142
• Web-browser access from any computer on your network
• Works with Varian, Elekta, Aria, Mosaiq
Bene ts• Complete library of most common TG-142 imaging and
mechanical tests
• Complete automation - no additional time requirements -
simply approve results when ready
SNC Machine™
1 I www.lightages.com28 | SUN NUCLEAR CORPORATION // sunnuclear.com
PRODUCT SOLUTIONS // Machine QA
Compatible Linacs: (IMF) Elekta, Siemens, Varian
Weight (kg): (IMF-E) 7.9, (IMF-S) 8.1, (IMF-V) 7.4
Maximum Buildup (cm): (IMF)
Dimensions (cm):(IMF-E) 39.4 x 28.7 x 48.8
(IMF-S) 39.4 x 31.5 x 48.0
(IMF-V) 39.4 x 31.5 x 39.1
Compatible Linacs: (GMF) Elekta, Varian
Weight (kg): (GMF-E) 16.8, (GMF-V) 3.7
Maximum Buildup (cm):(GMF-E, ICP only) 3
(GMF-V, ICP only) 1.5
Dimensions (cm):(GMF-E) 56.5 x 56.5 x 56.0
(GMF-V) 40.0 x 47.1 x 42.2
Applications• Measure output, symmetry, flatness, field size,
penumbra, beam center, and more at any angle.
• Determine gravity-induced dose constancy, symmetry,
flatness, MLC and jaw shift changes
• Holds cones of 20 x 20 cm or less for performing
electron measurements
Highlights• Hold device measurement planes at machine isocenter:
IMF: MapCHECK®, MapCHECK 2, PROFILER™ 2,
Daily QA™3, rf-Daily QA3, and SRS PROFILER™ with
adapter plat
GMF: MapCHECK 2, PROFILER 2 and Daily QA 3
(adapter plate required)
Key Bene ts• Fast, efficient, reproducible setup
• Measure at 100 cm SDD +/- 1.0 mm
• Supports electron cone (GMF)
• Aluminum alloy construction
Adjustable buildup clamps
IMF™ GMF™/
Tests
TG-142 Imaging:
CBCT Image Quality & Accuracy, kV Image Quality & Accuracy, MV Image Quality & Accuracy
TG-142 Mechanical:
MLC Picket Fence, MLC Positioning & Leaf Speed, Winston-Lutz Radiation & Machine Isocenter, Gantry/Couch/Collimator Starshot, Light/Radiation Congruence, Field Size
Beam: Beam Flatness, Beam Symmetry
VMAT:Dose Rate versus Gantry Speed, Leaf Speed, Arc Point Dose, DMLC Point Dose
Applications• Image scaling, positioning offset, spatial resolution,
contrast, uniformity and noise
• Easy setup, alignment clearly marked on overlay and image
Applications• Symmetric and asymmetric light field/radiation field
coincidence and jaw positioning
• Flatness and symmetry for photon and electron beam
profile constancy
Applications• Winston-Lutz measurements
• Imaging and radiation field isocenter coincidence
• Cone-beam CT positioning/repositioning
• End-to-end IGRT positioning tests
• 3D isocenter offset results
Dimensions (cm): 6.0 x 6.0 x 6.0
Sphere Size (mm): 7.0
Sphere Center Accuracy (mm): 0.2
Field Sizes (cm): 10 x 10; 15 x 15
Markers (±0.1mm): 56 - Field size (7 per fi eld edge)
Dimensions (cm): 17.8 L x 17.8 W x 0.6 D
MV Line Pairs (mm): 0.1, 0.2, 0.5, 1.0 ± 0.025
MV ROI: 9 (4 spatial, 4 contrast, 1 center)
MV Dimensions (cm): 12.7 L x 10.2 W x 2.5 D
Applications• I mage scaling, positioning offset, spatial resolution, contrast,
uniformity and noise
• Easy setup, alignment clearly marked on overlay and image
kV Line Pairs (mm): 0.6, 1.2, 1.8, 2.4 ± 0.01
kV ROI: 28 (4 spatial, 23 contrast, 1 center)
kV Dimensions (cm): 12.7 L x 12.7 W x 1.6 D
sunnuclear.com // SUN NUCLEAR CORPORATION | 29
SNC Machine Options
MV-QA FS-QA: Field Size QA and Constancy
kV-QA WL-QA: Isocenter QA and Constancy
SNC Machine Compatability
R&V Systems: ARIA® and MOSAIQ® with Varian® linacs
kV:ImagePro kV , LEEDS TOR 18FG, Standard Imaging QC-kV1
MV:ImagePro MV, Varian Las Vegas, Standard Imaging QC-3
CBCT:Varian CATPHAN (Model 504), ElektaCATPHAN (Model 503), CATPHAN 600, Gammex 464
Winston-Lutz: ImagePro WL-QA, custom phantom
Field Size: ImagePro FS-QA, custom phantom
Log Files: Varian Dynalog
Browsers:IE9 with Windows 7; IE 11 with Windows 8.1; Google Chrome
Tools used for dosimetry and commissioning must be carefully selected. Equal care must be taken to use the tools properly, otherwise incorrect information could be used with serious consequences. It is with this understanding that Sun Nuclear designs dosimetry solutions. Our goal for dosimetry is to maximize the accuracy of the measurement while minimizing the possibility of incorrect use.
Maximize Measurement Accuracy While
MINIMIZING INCORRECT USE
1 I www.lightages.com30 | SUN NUCLEAR CORPORATION // sunnuclear.com
PRODUCT SOLUTIONS // Dosimetry
3D SCANNER™
Applications• TPS commissioning
• Linac acceptance
• Annual QA
Highlights• Patented cylindrical design scans on any axis
• Ring drive positions detector in any relevant 3D location
• Automated leveling and beam center positioning
• Built-in control box/electrometer
• Works with both diodes and ion chambers
Key Bene ts• 0.1 mm positioning accuracy
• Reproducible setup
• Less than 20 minute setup
• 65 cm scan range; no need for tank shift
The Cylindrical Advantage• Maintains ideal orientation of the detector during inline,
crossline and diagonal scans
• More scanning area - up to 65 cm in any direction
• Less volume means faster fill and drain time
• No need to shift the tank and risk setup inconsistencies
during shifting
• Water riples settle faster because of curved walls
AutoSetup™
• No more guess work, highly reproducible setup result.
• Ready to setup in less than 20 minutes
Vertical (mm): 400
Diameter (mm): 650
Ring (Degrees): 330
Motors: Encoded stepper/servo
Scanning Modes: Continuous and step
Scanning Speed Range (mm/sec): Variable up to 8
Scanning Accuracy (mm): 0.1 in all dimensions
Diameter inner, Height / Width (mm): 676 / 673 / 875
sunnuclear.com // SUN NUCLEAR CORPORATION | 31
3D MiniLift™
Highlights• Straddles linac couch ring for stability
• Fits through standard doorways
• Legs fold for compact storage
• Quick and easy disassembly or transport
Highlights• 187 L (49.5 gal) capacity
• Less than 6 minute fill time
• Less than 3 minute drain time
• Easily maneuverable
3D SCANNER Options
3D Reservoir™
Highlights• Supports Varian®, Elekta®, Siemens® and CyberKnife®
delivery systems
• Less than 5-minute installation with no additional tools
• 200 mm TPR drain measurement: 1.2 minutes
• 200 mm TPR fill measurement: 2.7 minutes
3D TPR™
1D SCANNER™
Applications• Detector positioning in water
• Output factors and dose calibrations
• Annual and routine QA
Highlights• Suitable for TG-51
• Automatic water level detection
Places the detector at the water surface
• Pendant and PC software control
• 30 cm scan depth
• Advanced scanning software option available
Key Bene ts• Fast and efficient detector positioning
• Accommodates all common electron cones
• Multi-function pendant
• Horizontal ruler for off-axis detector positioning
• Farmer type, universal, and reference detector
holders included
• Leveling platform available
Inner Dimensions (cm): 35 x 39 x 36
Inner Volume (cm): 48 liters at 34.5
Arm positioning Increments (cm): 0.01, 0.1, 1.0 & 10
Arm positioning Accuracy (cm): ± 0.01
Scan Depth Maximum (cm): 30
Tank Material: PMMA (Acrylic)
Weight Empty with Arm (kg): 10.9
Detector Type: SunPoint Diode Detectors
Quantity: 127
Spacing: (mm): 4
Overall Active Length (mm) 504
Active Volume (mm3): 0.019
Inherent Buildup Depth (mm): 8.1
Physical Buildup Depth (mm): 5.8
Sensitivity (nC/Gy): 32
1 I www.lightages.com32 | SUN NUCLEAR CORPORATION // sunnuclear.com
PRODUCT SOLUTIONS // Dosimetry
WaterProof PROFILER™
Applications• Scanning Dosimetry - relative dose measurements, acceptance
testing, TPS commissioning
• Open Fields and Electronic Wedges
Highlights• Single power/data cable connects directly to 3D SCANNER
• Oversampling feature provides accurate results
• Best specification detector spacing, count, and array length of
any water-proof array
• SunPoint Diode Detectors provide the sharpest penumbra for
the highest accuracy in beam modeling
• Calibration is fully automated and performed in the 3D
SCANNER with no need to go in and out of bunker
Key Bene ts• Speed – capture complete beam profiles instantly, and with a
fraction of the MU’s needed when using a single detector
• Accuracy – data is comparable to data collected when using a
single ion chamber
• Ease of use – attaches directly to 3D SCANNER in seconds
with no tools, warm-up, or external electrometer needed
3D SCANNER Options
PC Electrometer™ EDGE Detector™
Applications• SRS and IMRT beam modeling
• TPS commissioning
Highlights• Accurate penumbra characterization for all fields
• Ideal for steep dose gradients and small fields
• On Accuray® Recommended QA Equipment list
• 842 times smaller in volume than micro ion chambers
• 100 times more signal than micro ion chambers
Key Bene ts• No dose volume averaging
• Accuracy for critical penumbra measurements
• Works with all common water phantoms
Detector type: SunPoint® Diode Detector
Diode Die Location (mm):
0.3 from top
4.72 from end
2.7 from side
Indicated by cross hairs on top
of housing
Water Depth Equivalent (mm): 0.5
Housing Wall Thickness (mm): 0.13, brass
External Dimensions (mm): 3.8 x 5.5 x 38
Impedance: >200 Mohm at 10 mV reverse bias
Output Polarity: Negative
Cable: 3.4 mm dia. x 1.8 m long, triax
Connector: TNC or BNC
Charge (mCa): 2 pC – 10
Current Range Continuous (nA): 2 pA – 50
Current Range Pulsed (pC/pulse): 0 -105
Leakage (fA): < 10
A/D Converter: 16 bit
Non-Linearity: <+/- 0.1% of full scale
Long Term Stability: <+/- 0.5%
Measured Repeatability: <+/- 0.25% of full scale
Connector: TNC or BNC
Weight (kg): 0.4
Current Range Pulsed (pC/pulse): 0 -105
Applications• Reference class dosimetry for absolute dose calibration
• Mobility intensive assignments
Highlights• Lightweight and portable; weighs only 1 lbs
• USB powered — no batteries or power cord
• Intuitive user interface
• Fully configurable software interface
Key Bene ts• Pocket size, lightweight design
• Two independent measurement channels
• Interfaces with the 1D SCANNER
• Less than 1-minute warm-up time
• Single USB cable connection
• Fast sampling interval 500 ms
• Detector library
sunnuclear.com // SUN NUCLEAR CORPORATION | 33
SNC350p™ SNC125c™
Applications• Reference, field, and scanning dosimetry of electron beams
• TDD/TPS Commissioning and QA
Highlights• Conforms to the design principles as stated by Dr. M. Roos
• Meets AAPM TG-51 and IAEA TRS-398 requirements for
low-energy beams
• Reference dosimeter can be used to cross calibrate
field dosimeters
• Meets highest standards of performance (IEC 60731)
Key Bene ts• Well-guarded to reduce in-scattering perturbation effects
• Vented to provide air-density correction and eliminate need
for radioactive stability check device
• White chamber body allows easy visualization of the setup
relative to the crosshairs and lasers
Sensitive Volume (cm3): 0.388
Reference Point (mm): 1.07 Below Window Surface
Collection Volume Height (mm): 2.0
Collector Diameter (mm): 15.6
Guard Ring Width (mm): 4.1
Polarity Effect: Within 1.000 (±) 0.01
Max Dose Rate for (Gy/s):≥ 99.5 % Saturation≥ 99.0 % Saturation
5.2
10.4
Max Dose Per Pulse for (mGy):≥ 99.5 % Saturation≥ 99.0 % Saturation
0.46
0.92
Radiation Quality:Photons: 60Co to 25 MV
Electrons: 5 MeV to 25 MeV
Connector: TNC or BNC
Applications• Reference, Field, Scanning dosimetry of electron and
photon beams
• IMRT/VMAT Quality Assurance
Highlights• Intended for use in scanning, field and reference dosimetry
• Enhanced penumbra without loss of signal strength
Key Bene ts• Waterproof and fully guarded
• Vented to provide air-density correction and eliminate the
need for radioactive stability check device
• White chamber body gives a clear line of sight to the
crosshairs and lasers during set up and set up verification
Active Volume (cm3): 0.108
Active Length (mm): 7.05
Active Diameter (mm): 4.75
Sensitivity (nC/Gy): 3.4
Wall Material (mm):Paint 0.05
PMMA 0.30
Graphite 0.25
Electrode (mm): 0.8 diameter aluminum
Vented:To atmosphere through
waterproof tubing
Waterproofi ng: Viton Tubing
Polarizing Voltage: ±400V Max
Cable Length (m): 1.5
Cable Connector: TNC or BNC
1 I www.lightages.com34 | SUN NUCLEAR CORPORATION // sunnuclear.com
PRODUCT SOLUTIONS // Dosimetry
Active Volume (cm3): 0.6
Active Length (mm): 22.7
Active Diameter (mm): 6.1
Sensitivity (nC/Gy): 20
Wall Material (mm): Paint 0.05, Graphite 0.43
Electrode (mm): 1.1 diameter aluminum
Vented:To atmosphere through
waterproof tubing
Buildup Cap (mm): 4.5
Polarizing Voltage: ±400V Max
Cable Length (m): 1.5
Cable Connector: TNC or BNC
“The tank setup is by far the easiest setup of a scanning tank I have ever used and a testament to the ground up approach to the engineering of this scanning system. From my experience with D SCANNER, I’ll be a Sun Nuclear tank user for all of my future sites.
Mike Tallhamer, M.ScChief of Physics
Centura Health, Colorado, USA
sunnuclear.com // SUN NUCLEAR CORPORATION | 35
3D SCANNER™SNC600c™
Applications• Photon and electron dosimetry
• Reference dosimetry - treatment delivery device calibration,
cross calibration of other ionization chambers
• Field dosimetry - output stability checks for QA
• Scanning dosimetry - relative dose measurements, acceptance
testing, treatment planning system commissioning
Highlights• Reference class ionization chamber (IEC 60731)
• Follows industry classic Farmer chamber design
• Fully guarded
• Vented
• Waterproof
• White thimble provides cross hair contrast
• Rotational orientation indicator mark
• Included Co-60 cap allows for air KERMA calibration
Key Bene ts• Compatiability for existing Farmer chamber phantoms due to
classic Farmer chamber design
• Highest performance for reference dosimetry
• Improved setup and accuracy from white chamber body gives
a clear line of sight to the crosshairs and lasers during set up
and set up verification
ProSol_B040715©2015 Sun Nuclear Corporation. All Rights Reserved. All data used is best available at time of publication. Data is subject to change without notice.