Product Model Number Guide12.04.17 1
PRODUCT MODEL NUMBER
GUIDE
Product Model Number Guide12.04.172
TABLE OF FIGURES
Figure 1 - gForce Ultra Systems (Single & Dual Circuit) .........................................3
Figure 2 – gForce In-Row Systems (Single Circuit) ..................................................3
Figure 3 - GT Systems (Single Circuit) ......................................................................4
Figure 4 - gForce Systems (Dual Circuit) ..................................................................5
Figure 5 - Data Temp Systems (Single Circuit) ........................................................6
Figure 6 - Modular Data Temp Systems (Single Circuit) ........................................6
Figure 7 - Data Aire Systems (DX) .............................................................................7
Figure 8 - Data Aire Systems (Chilled Water) ..........................................................7
Figure 9 - Mini Ceiling Systems (Single Circuit) ......................................................8
Figure 10 - Mini-Plus Ceiling Systems (Single Circuit) ...........................................8
Figure 11 - Large Ceiling Systems (Single OR Dual Circuit) ..................................9
Figure 12 – Outdoor Remote Condensers (RC) ....................................................10
Figure 13 - Outdoor Condensing Units (CU) ........................................................10
Figure 14 - Indoor “Piggy-Back” Remote Condenser (RC + PB) .........................10
Figure 15 - Outdoor Fluid Coolers (FC) .................................................................11
Figure 16 – Indoor “Piggy-Back” Fluid Cooler (FC + PB) .....................................11
Figure 17 - Data Cool Systems (Single Circuit) .....................................................12
Figure 18 - Shelf Systems (Single Circuit) ..............................................................12
Product Model Number Guide12.04.17 3
FLOOR UNITS (VARIABLE SPEED COMPRESSOR)
Figure 1 - gForce Ultra Systems (Single & Dual Circuit)
RACK & ROW(FIXED/VARIABLE SPEED COMPRESSOR:
Figure 2 - gForce In-Row Systems (Single Circuit)
gForce Ultra
A U - 3GU 2022
gForce Ultra, Single and Dual Circuit
A----- Air CooledW - Water CooledG - Glycol Cooled
D - Downf ow U ---- Upf ow
Nominal Kilowatts022kW 036kW045kW070kW091kW125kW
Phase 3 - Three phase
Voltage2 - 208/230 V 4 - 460 V
CW - 3GI 4035
Data Aire gForce IR
AX------Air CooledWX - Water CooledGX - Glycol Cooled
035kW -AX, WX or GX **
020kW -AX *030kW -CW
010kW -AX *
060kW -CW
1 - Single Phase3 - Three phase
2 - 208/230 volt 4 - 460 volt
CW - Chilled Water
022kW -AX, WX or GX **
Note: Each image will hyperlink to our website and the product’s supporting documentation
MODEL NUMBER IDENTIFICATION
gForce IRMODEL NUMBER IDENTIFICATION
Single Circuit
Voltage
Phase
Nominal Kilowatts
single circuit: 022, 036, 045dual: 070, 091, 125
12” Cabinet:
24” Cabinet:
* Fixed speed compressor** Variable speed compressor
12” cabinet 24” cabinet
Product Model Number Guide12.04.174
FLOOR UNITS
A D - 3GT 4035
gForce Series Single Circuit
A------Air CooledW - Water CooledG - Glycol Cooled
D - Downf ow U ---- Upf ow
Nominal Kilowatts
1 - Single Phase3 - Three phase
2 - 208 or 230 V4 - 460 V5 - 575 V
CC - Auxillary Chilled Water Coil
E - Energy Saver Coil (Water/Glycol Cooled Units)
(Air or Water Cooled Units)
Figure 3 - GT Systems (Single Circuit)
GT SystemsMODEL NUMBER IDENTIFICATION
Voltage
Phase
007-046 kW
Product Model Number Guide12.04.17 5
C - Auxillary Chilled Water Coil A D - 3GF 4035
gForce Systems Dual Circuit
A ------ Air CooledW --- Water Cooled
G --- Glycol Cooled
D - Downf owU ---- Upf ow
Nominal Kilowatts
1 - Single Phase3 - Three phase
2 - 208 or 230 V
4 - 460 V
EC - Auxillary Chilled Water Coil
E - Energy Saver Coil (Water/Glycol Cooled Units)
(Air or Water Cooled Units)
DX Units (Link)
Figure 4 - gForce Systems (Dual Circuit)
gForce SystemsMODEL NUMBER IDENTIFICATION
Voltage
Phase
3 - 380 or 400 VC --- Chilled Water
021 - 106 kW
Chilled Water Units (Link)
Product Model Number Guide12.04.176
FLOOR UNITS (Cont.)
A D - 1DT 205
DATA TEMP
D - Downf owU ---- Upf ow
Nominal tons 1 - Single Phase3 - Three phase
2 - 208 or 230 V4 - 460 V5 - 575 V
CC - Auxillary Chilled Water Coil
E - Energy Saver Coil (Water/Glycol Cooled Units)
(Air or Water Cooled Units)
A--------Air Cooled
G --- Glycol CooledC --- Chilled Water
W --- Water Cooled
Figure 5 - Data Temp Systems (Single Circuit)
A D - 3DT 208
A ---- Air CooledW - Water CooledG - Glycol Cooled
D - Downf owU ---- Upf ow
3 - Three phase
DATA TEMP
Nominal tons
2 - 208 or 230 V 4 - 460 V 5 - 575 V
Figure 6 - Modular Data Temp Systems (Single Circuit)
Data Temp SystemsMODEL NUMBER IDENTIFICATION
Modular Data Temp SystemsMODEL NUMBER IDENTIFICATION
-
2-5 tons
8-13 tons
Phase
Voltage
Voltage
Phase
MODULAR
C - Chilled Water
Product Model Number Guide12.04.17 7
C - Auxillary Chilled Water CoilA D 3DA 220
DATA AIRE
D - Downf owU --- Upf ow
Nominal tons
3 - Three phase
2 - 208 or 230 V 4 - 460 V 5 - 575 V
C C - Auxillary Chilled Water Coil
E - Energy Saver Coil (Water/Glycol Cooled Units)
(Air or Water Cooled Units)
A------Air CooledW - Water CooledG - Glycol Cooled
Data Aire Systems (DX)MODEL NUMBER IDENTIFICATION
Figure 7 - Data Aire Systems (DX)
Figure 8 - Data Aire Systems (Chilled Water)
C D 3DA 415
D - Downf owU ---- Upf ow
3 - Three phase
DATA AIRE
Nominal tons
2 - 208 or 230 V4 - 460 V5 - 575 V
C - Chilled Water
Data Aire Systems (Chilled Water)MODEL NUMBER IDENTIFICATION
- -
-
Voltage
Phase
Voltage
Phase
06 - 30 tons
07 - 50 tons
Product Model Number Guide12.04.178
CEILING UNITS
A 01 2DAM P1
01, 1.5, 02 and 2.5
CEILING SYSTEM
1 - Single Phase
2 - 208, 230 or 270 V
DATA AIRE MINI
A ------ Air Cooled
W --- Water CooledC --- Chilled Water
G --- Glycol Cooled
Nominal tons
P - Package System
CO - Split system withoutdoor condenser(DARC)
AO - Split system withoutdoor condensing unit(DRCU)
AI - Split system withindoor condensing unit(DAAC)
CONDENSER - Condenser coil only, no compressorCONDENSING UNIT - Condenser coil and compressor
The order write up should have the condenser or condensing unit model number. Refer to applicable condenser or condensing model number identification.
Example: DATA AIRE MINI, air cooled, 1 ton, 10 - 230 volts, packaged system DAMA 0112 P
Figure 9 - Mini Ceiling Systems (Single Circuit)
A 2.5 2 CO1
2.5, 03, 04 and 05
CEILING SYSTEM
1 - Single Phase
DATA AIRE MINI-PLUS
A ------ Air Cooled
W -- Water CooledC --- Chilled Water
G --- Glycol Cooled
Nominal tons
P - Package System
CO - Split system withoutdoor condenser(DARC)
CI - Split systems withindoor condenser(DAIC)
AO - Split system withoutdoor condensing unit(DRCU)
AI - Split system withindoor condensing unit(DAAC)
3 - Three Phase
2 - 208 or 230 V 4 - 460 V5 - 575 V
E
C - Auxilary chilled
E - Energy SaverFigure 10 - Mini-Plus Ceiling Systems (Single Circuit)
Mini Ceiling SystemsMODEL NUMBER IDENTIFICATION
Mini-Plus Ceiling SystemsMODEL NUMBER IDENTIFICATION
- -
- - -
water coil
DAP
CO - Split system withindoor condenser(DAIC)
Phase
Voltage
Phase
Voltage
Product Model Number Guide12.04.17 9
CO - Split system with
outdoor condensing unit
CO - Split system with
CI - Split systems with
AO - Split system withoutdoor condensing unit
AI - Split system withindoor condensing unit
C - Auxilary chilled
E - Energy Saverwater coil
CO - Split system with
A 06 2DAL CO3
06, 08, 10 and 13
DATA AIRE LCS UNIT
Nominal tons
P - Package System
CO - Split system withoutdoor condenser(DARC)
AO - Split system withoutdoor condensing unit(DRCU) 3 - Three Phase
2 - 208 or 230 V4 - 460 V
E D
D - Dual CompressorS - Single Compressor
5 - 575 V
LCS units are not available in air cooled packaged configuration.
CONDENSER - Condenser coil only, no compressorCONDENSING UNIT - Condenser coil and compressor
The order write up should have the condenser or condensing unit model number. Refer to applicable condenser or condensing model number identification.
Example: DATA AIRE LCS UNIT, air cooled, 6 ton, 30 - 230 volts, split system with outdoor condenser and dual compressors - Evaporator model: DALA 0632 CO D Condenser model: DARC 0632
Figure 11 - Large Ceiling Systems (Single or Dual Circuit)
Large Ceiling SystemsMODEL NUMBER IDENTIFICATION
- - - -
A ------ Air Cooled
W --- Water CooledC --- Chilled Water
G --- Glycol Cooled
C - Auxilary chilled
E - Energy Saverwater coil
Single or Dual Circuit
Voltage
Phase
Product Model Number Guide12.04.1710
HEAT EXCHANGERS
RC 035 4GH LD3
1 - Single Phase
Remote Condenser - RC
gForce EC fans - GHPSC fans - DA
Nominal tons - Data Aire
3 - Three Phase
2 - 208 or 230 volt4 - 460 volt
LD - Low decibel
Figure 12 - Outdoor Remote Condensers (RC)
CU 05 2DR 1
1 - Single Phase
gForce EC fans - GHPSC fans - DA
Nominal tons - Data Aire
3 - Three Phase
2 - 208 or 230 volt4 - 460 volt
CU - Remote Condensing UnitHCU - Rejection Remote Condensing Unit
Kilowatts - gForce
Figure 13 - Outdoor Condensing Units (CU)
Figure 14 - Indoor “Piggy-Back” Remote Condenser (RC+PB)
Model DARC 07xx-PB
DARC 09xx-PB
DARC 11xx-PB
DARC 15xx-PB
DARC 17xx-PB
DARC 21xx-PB
DARC 24xx-PB
DARC 28xx-PB
DARC 07xx-PB to DARC 09xx-PB are single fan units.
DARC 11xx-PB to DARC 28xx-PB are dual fan units.
Outdoor Remote Condensers (RC)MODEL NUMBER IDENTIFICATION
Outdoor Condensing Units (CU)MODEL NUMBER IDENTIFICATION
- -
-
Voltage
Phase
Voltage
Phase
* Only on DA Series for for LD
Kilowatts - gForce
Product Model Number Guide12.04.17 11
FC 06 2DA LD1
1 - Single Phase
FC - Fluid Cooler
Nominal tons
3 - Three Phase
2 - 208 or 230 volt4 - 460 volt
LD - Low decibelPB - Indoor Centrifugal
Figure 15 - Outdoor Fluid Coolers (Dry Coolers) (FC)
Model • DAFC-06-PB
• DAFC-07-PB
• DAFC -09-PB
• DAFC -11-PB
• DAFC -15-PB
• DAFC -17-PB
• DAFC -21-PB
• DAFC-28-PB
Figure 16 - Indoor “Piggy-Back” Fluid Cooler (FC+PB) (Dry Coolers)
Outdoor Fluid Coolers (Dry Coolers)(FC)MODEL NUMBER IDENTIFICATION
- -
Phase
Voltage
PSC fans - DAgForce EC fans - GH
Product Model Number Guide12.04.1712
A 02 2DC AO1
02 and 03
1 - Single Phase
2 - 208, 230 volt
DATA COOL
Nominal tons
AO - Split system withoutdoor condensing unit(DRCU)
AI - Split system withindoor condensing unit(DAAC)
Figure 17 - Data Cool Systems (Single Circuit)
A 02 2DAS CO1
1 - Single Phase
Nominal tons
SHELF SYSTEMDATA AIRE
02, 03 and 04
3 - Three Phase
2 - 208 or 230 volt4 - 460 volt5 - 575 volt
P - Package System Fluid cooler identifi cation may be required for glycol cooled units. (DAFC)
SHELF SYSTEMS units are not available in air cooled packaged configuration.
CONDENSER - Condenser coil only, no compressorCONDENSING UNIT - Condenser coil and compressor
The order write up should have the condenser or condensing unit model number. Refer to applicable condenser or condensing model number identification.
Example: DATA AIRE SHELF SYSTEM, air cooled, 2 ton, 10 - 230 volts, split system with outdoor condenser Evaporator model: DASA 0212 CO Condenser model: DARC 0312
Figure 18 - Shelf Systems (Single Circuit)
Data Cool SystemsMODEL NUMBER IDENTIFICATION
Shelf SystemsMODEL NUMBER IDENTIFICATION
- -
- -
Single Circuit
Single Circuit
A ------ Air Cooled
W --- Water CooledC --- Chilled Water
G --- Glycol Cooled
A ------ Air Cooled
W --- Water CooledC --- Chilled Water
G --- Glycol Cooled
CO - Split system withoutdoor condenser(DARC)
CI - Split systems withindoor condenser(DAIC)
AO - Split system withoutdoor condensing unit(DRCU)
AI - Split system withindoor condensing unit(DAAC)
Voltage
Phase
Phase
Voltage
U
U - Upf ow
SPECIALTY UNITS