Price list 2009 Ultrasonic - Flowmeters Index SOME ... ISE... · Price list 2009 Ultrasonic -...

27
Price list 2009 Ultrasonic - Flowmeters Index Rev.00 SOME INFORMATION CONTENT page(s) 01 - 02 03 - 04 05 - 06 07 08 09 10 11 12 13a - 14a 13b - 14b 13c - 14c 15 16 17 18 GFC 060 UFM 610 P OPTISONIC 7000 DN 2” - 24” Ex-i version UFC 300 Modular version OPTISONIC 6000 UFC 300 Basic version DN 4” - 12” UFC 030 UFS 500 HT UFS 3000 Documentation DN 1” - 3” For exact determination of Ultrasonic Flowmeters we require the following specifications: spec. gravity, viscosity, acoustical conductivity, physical characteristics (e.g. crystallising), operating temperature and pressure, flow rate per time unit, analogue and pulse output, Ex- approval, power supply Under consideration of the specific application and after decision of the measuring principle and instrument type, the required instrument version can be taken out of the Price list. This Price list contains all instrument versions of a.m. product group. The ordering codes are constructed in such way that your order can be placed either by using the V-number or by product description. In case accessories and spare parts are ordered, the indication of the stock number is sufficient. Our Price list contains the standard program. For special versions please contact us directly. KROHNE Ultrasonic Flowmeters are suitable for the measurement of fluids and gases which have to be acoustical conductive. For detailed information with regard to the following items please kindly refer to our technical data sheets: The purchaser is solely responsible for the suitability in accordance with the technical regulations and applicability of our instruments. All instruments will be tested by our Final Quality Assurance prior to shipment. Our QA System is approved according to DIN ISO 9000. Our General Terms & Conditions and the latest edition of INCOTERMS are valid. The prices mentioned in our pricelist are to be understood without VAT. We reserve the right of technical changes and price modifications. Please visit us at: www.configureit.de Here you have the opportunity to configure our instruments directly, online, non-binding and without any software installation. DN 1” - 2 1/2” DN 3” - 12” UFS 3000 UFS 3000 DN 14” - 80” UFS 3000 Extended standard PN UFS 3000 OPTISONIC 7000 Extended standard PN UFS 500 HT UFC 300 measuring principle, project engineering guidelines, application fields, operating data, min. and max. flowrates

Transcript of Price list 2009 Ultrasonic - Flowmeters Index SOME ... ISE... · Price list 2009 Ultrasonic -...

Page 1: Price list 2009 Ultrasonic - Flowmeters Index SOME ... ISE... · Price list 2009 Ultrasonic - Flowmeters Index Rev.00 SOME INFORMATION ... Our QA System is approved according to DIN

Price list 2009 Ultrasonic - Flowmeters Index Rev.00

SOME INFORMATION CONTENTpage(s)01 - 0203 - 0405 - 06

070809101112

13a - 14a13b - 14b13c - 14c

15161718

GFC 060

UFM 610 POPTISONIC 7000 DN 2” - 24”

Ex-i versionUFC 300 Modular version

OPTISONIC 6000UFC 300 Basic version

DN 4” - 12”

UFC 030

UFS 500 HTUFS 3000 Documentation

DN 1” - 3”

For exact determination of Ultrasonic Flowmeters we require thefollowing specifications:

spec. gravity, viscosity, acoustical conductivity, physical characteristics (e.g. crystallising), operating temperature and pressure, flow rate per time unit, analogue and pulse output, Ex-approval, power supply

Under consideration of the specific application and after decision of themeasuring principle and instrument type, the required instrumentversion can be taken out of the Price list.

This Price list contains all instrument versions of a.m. product group.

The ordering codes are constructed in such way that your order can beplaced either by using the V-number or by product description. In caseaccessories and spare parts are ordered, the indication of the stocknumber is sufficient. Our Price list contains the standard program. Forspecial versions please contact us directly.

KROHNE Ultrasonic Flowmeters are suitable for the measurement offluids and gases which have to be acoustical conductive.

For detailed information with regard to the following items please kindlyrefer to our technical data sheets:

The purchaser is solely responsible for the suitability in accordance withthe technical regulations and applicability of our instruments.

All instruments will be tested by our Final Quality Assurance prior toshipment. Our QA System is approved according to DIN ISO 9000.

Our General Terms & Conditions and the latest edition of INCOTERMSare valid. The prices mentioned in our pricelist are to be understoodwithout VAT.

We reserve the right of technical changes and price modifications.

Please visit us at:

www.configureit.de

Here you have the opportunity to configure our instruments directly,online, non-binding and without any software installation.

DN 1” - 2 1/2”DN 3” - 12”UFS 3000

UFS 3000 DN 14” - 80”UFS 3000 Extended standard PN

UFS 3000

OPTISONIC 7000 Extended standard PN

UFS 500 HT

UFC 300

measuring principle, project engineering guidelines, application fields, operating data, min. and max. flowrates

Page 2: Price list 2009 Ultrasonic - Flowmeters Index SOME ... ISE... · Price list 2009 Ultrasonic - Flowmeters Index Rev.00 SOME INFORMATION ... Our QA System is approved according to DIN

Price list 2009 Ultrasonic flowmeter system UFM 3030: Page 01 Rev.00

Sensor UFS 3000, triple beam version UFS 3000for connection to flow converter UFC 030 DN 25 - 65 / 1" - 2 1/2"

Base priceCode SensorVN51 4 Nominal diameter

4 UFS 3000 DN 25 / 1" 0 5 UFS 3000 DN 32 / 1 1/4" 0 6 UFS 3000 DN 40 / 1 1/2" 0 7 UFS 3000 DN 50 / 2" 0

8 UFS 3000 DN 65 / 2 1/2" 0Nominal pressure Price adder

5 PN 40 EN 1092-1 Stainless steel 316 L 06 PN 63 EN 1092-1 Stainless steel 316 L see page 077 PN 100 EN 1092-1 Stainless steel 316 L see page 07A ASME B 16.5 150 lb RF Stainless steel 316 L 0B ASME B 16.5 300 lb RF Stainless steel 316 L see page 07D ASME B 16.5 600 lb RF Stainless steel 316 L see page 07M JIS 20K Stainless steel 316 L ( DN 25 - DN 40 ) see page 07N JIS 10K Stainless steel 316 L ( DN 50 - DN 65 ) see page 07

Design / protection class / max. medium temperature1 compact with UFC 030 K / IP 67 - 140 °C / 282 °F 02 separate with UFC 030 F / IP 67 - 180 °C / 356 °F 03 separate with UFC 030 F / IP 68 - 180 °C / 356 °F ( not FM, CSA & TIIS approved ) 04 separate with UFC 030 F / IP 67 - 220 °C / 428 °F 05 separate with UFC 030 F / IP 68 - 220 °C / 428 °F ( not FM, CSA & TIIS approved ) 0A compact with UFC 030 K / IP 67 - 140 °C / 282 °F, prepared for stainless steel converter housing 0B separate with UFC 030 F / IP 67 - 180 °C / 356 °F, with stainless steel connection box 0C separate with UFC 030 F / IP 67 - 220 °C / 428 °F, with stainless steel connection box 0

Approval0 without 01 EEx zone 1 03 FM Class I DIV 1 ( USA ) 04 FM Class I DIV 2 ( USA ) 06 CSA Class I DIV 1 ( Canada ) 07 CSA Class I DIV 2 ( Canada ) 0A TIIS ( Japan ) 0B CSA Class I DIV 1 ( Dual seal ) 0C CSA Class I DIV 2 ( Dual seal ) 0

Cable connection1 at converter ( compact version ) 03 2 x 1/2" NPT ( separate version ) 04 2 x PF 1/2" ( separate version ) 05 2 x M20 x 1,5 ( separate version ) 0

Tube- / flange material2* SS 316 L / SS 316 L ( butt weld version ) 0

Page 3: Price list 2009 Ultrasonic - Flowmeters Index SOME ... ISE... · Price list 2009 Ultrasonic - Flowmeters Index Rev.00 SOME INFORMATION ... Our QA System is approved according to DIN

Cable0* standard ( compact none, separate 5 m ) 01 10 m ( separate version ) 02 15 m ( separate version ) 03 20 m ( separate version ) 04 25 m ( separate version ) 05 30 m ( separate version ) 0

Calibration0* 2 points with water 02 3 points with water acc. RVA 03 3 points acc. to EN1434-5 / MID-004 06 6 points with water, 1 point with 3 results ( 2 repeats ) 07 6 points with water bidirectional, 2 points with 3 results ( 2 repeats for 2 points ) 0

Finish1* KROHNE standard, silver ( RAL 9006 ) 02 blasted ( not coated ) 03 KROHNE offshore paint system, silver ( RAL 9006 ) 0A KROHNE standard + 304 / 1.4301 tagplate ( 67 x 25 mm ) 0B blasted ( not coated ) + 304 / 1.4301 tagplate ( 67 x 25 mm ) 0C KROHNE offshore + 304 / 1.4301 tagplate ( 67 x 25 mm ) 0

VN51 4 2 0 0 0 Custody Transfer Price adder0* Without 05 Water - hot, acc EN1434-4 CH ( not for DN 32 ) 06 Water - hot, acc EN1434-4 GE ( not for DN 32 ) 0K Water - hot, acc MI-004 EU ( not for DN 32 ) 0

Construction Requirements ( see page 09 )0* Standard 01 Group 1, gen. arr. drawing ( dimensions ) 02 Group 2, detailed prod. planning 03 Group 3, welding book 04 Group 4, stress calculations 0

QA/QC Requirements ( see page 09 )0* without 01 Group 1, decl. of compliance 2.1 02 Group 2, test.report 2.2 ( press. test ) 03 Group 3, insp. cert. EN 10204-3.1 ( press. test ) 04 Group 4, list of material certificates 05 Group 5, insp.& test plan ( QA checklist ) 06 Group 6, liquid (dye) penetration for all welds 07 Group 7, X-ray ( incl. dye pen.) 08 Group 8, PMI ( incl. dye pen. + X-ray ) 0

* Standard*** In preparation / pending.

VN51 4 2 0 0 0 Complete ordering code Higher pressure rating / other flange materials on requestSensor UFS 3000 can only operate in connection with signal converter UFC 030. See price list page 08.Required data in case of order: fluid - operating pressure - temperature of fluid - measuring range

Page 4: Price list 2009 Ultrasonic - Flowmeters Index SOME ... ISE... · Price list 2009 Ultrasonic - Flowmeters Index Rev.00 SOME INFORMATION ... Our QA System is approved according to DIN

Price list 2009 Ultrasonic flowmeter system UFM 3030: Page 03 Rev.00

Sensor UFS 3000, triple beam version UFS 3000for connection to flow converter UFC 030 DN 80 - 300 / 3" - 12"

Base priceCode SensorVN52 4 Nominal diameter

A UFS 3000 DN 80 / 3" 0 B UFS 3000 DN 100 / 4" 0

C UFS 3000 DN 125 / 5" 0D UFS 3000 DN 150 / 6" 0E UFS 3000 DN 200 / 8" 0F UFS 3000 DN 250 / 10" 0

G UFS 3000 DN 300 / 12" 0 Nominal pressure Price adder

2 PN 10 EN 1092-1 ( DN 200 - DN 300 ) see page 073 PN 16 EN 1092-1 ( DN 100 - DN 150 ) see page 074 PN 25 EN 1092-1 ( DN 100 - DN 300 ) see page 075 PN 40 EN 1092-1 ( DN 80 ) see page 07A ASME B 16.5 150 lb RF see page 07B ASME B 16.5 300 lb RF see page 07D ASME B 16.5 600 lb RF see page 07N JIS 10 K see page 07

Design / protection class / max. medium temperature1 compact with UFC 030 K / IP 67 - 140 °C / 282 °F 02 separate with UFC 030 F / IP 67 - 180 °C / 356 °F 03 separate with UFC 030 F / IP 68 - 180 °C / 356 °F ( not FM, CSA & TIIS approved ) 04 separate with UFC 030 F / IP 67 - 220 °C / 428 °F ( DN 80 - 150 / 3" - 6" ) 05 separate with UFC 030 F / IP 68 - 220 °C / 428 °F ( not FM, CSA & TIIS approved ) ( DN 80 - 150 / 3" - 6" ) 0A compact with UFC 030 K / IP 67 - 140 °C / 282 °F, prepared for stainless steel converter housing 0B separate with UFC 030 F / IP 67 - 180 °C / 356 °F, with stainless steel connection box 0C separate with UFC 030 F / IP 67 - 220 °C / 428 °F, with stainless steel connection box ( DN 80 - 150 / 3" - 6" ) 0

Approval0 without 01 EEx zone 1 03 FM Class I DIV 1 ( USA ) 04 FM Class I DIV 2 ( USA ) 06 CSA Class I DIV 1 ( Canada ) 07 CSA Class I DIV 2 ( Canada ) 0A TIIS ( Japan ) 0B CSA Class I DIV 1 ( Dual seal ) 0C CSA Class I DIV 2 ( Dual seal ) 0

Cable connection1 at converter ( compact version ) 03 2 x 1/2" NPT ( separate version ) 04 2 x PF 1/2" ( separate version ) 05 2 x M20 x 1,5 ( separate version ) 0

Tube- / flange material1* SS 316 L / steel slip on version Standard for DIN / JIS see page 072 SS 316 L / SS 316 L slip on version see page 07A SS 316 L / steel butt weld version Standard for ASME see page 07B SS 316 L / SS 316 L butt weld version see page 07

Cable0* standard ( compact none, separate 5 m ) 01 10 m ( separate version ) 02 15 m ( separate version ) 03 20 m ( separate version ) 04 25 m ( separate version ) 05 30 m ( separate version ) 0

Calibration0* 2 points with water 02 3 points with water acc. RVA 03 3 points acc. to EN1434-5 / MID-004 see page 046 6 points with water, 1 point with 3 results ( 2 repeats ) 07 6 points with water bidirectional, 2 points with 3 results ( 2 repeats for 2 points ) 0

Finish1* KROHNE standard, silver ( RAL 9006 ) 02 blasted ( not coated ) 03 KROHNE offshore paint system, silver ( RAL 9006 ) see page 04A KROHNE standard + 304 / 1.4301 tagplate ( 67 x 25 mm ) 0B blasted ( not coated ) + 304 / 1.4301 tagplate ( 67 x 25 mm ) 0C KROHNE offshore + 304 / 1.4301 tagplate ( 67 x 25 mm ) see page 04

Page 5: Price list 2009 Ultrasonic - Flowmeters Index SOME ... ISE... · Price list 2009 Ultrasonic - Flowmeters Index Rev.00 SOME INFORMATION ... Our QA System is approved according to DIN

Page 04 Rev.00

UFS 3000

VN52 4 0 0 Housing Price adder0* standard - steel ( only with silver finish ) 02 SS 316 L ( only with silver finish, option DN 80 / 3" ) 02 SS 316 L ( only with silver finish, option DN 100 / 4" ) 02 SS 316 L ( only with silver finish, option DN 125 / 5" ) 02 SS 316 L ( only with silver finish, option DN 150 / 6" ) 02 SS 316 L ( only with silver finish, option DN 200 / 8" ) 02 SS 316 L ( only with silver finish, option DN 250 / 10" ) 02 SS 316 L ( only with silver finish, option DN 300 / 12" ) 0

Custody Transfer0* Without 05 Water - hot, acc EN1434-4 CH ( not for DN 125 ) 06 Water - hot, acc EN1434-4 GE 0K Water - hot, acc MI-004 EU 0

Construction Requirements ( see page 09 )0* Standard 01 Group 1, gen. arr. drawing ( dimensions ) 02 Group 2, detailed prod. planning 03 Group 3, welding book 04 Group 4, stress calculations 0

QA/QC Requirements ( see page 09 )0* without 01 Group 1, decl. of compliance 2.1 02 Group 2, test.report 2.2 ( press. test ) 03 Group 3, insp. cert. EN 10204-3.1 ( press. test ) 04 Group 4, list of material certificates 05 Group 5, insp.& test plan ( QA checklist ) 06 Group 6, liquid (dye) penetration for all welds 07 Group 7, X-ray ( incl. dye pen.) 08 Group 8, PMI ( incl. dye pen. + X-ray ) 0

* Standard*** In preparation / pending.

VN52 4 0 0 Complete ordering code

Higher pressure rating / other flange materials on request

Sensor UFS 3000 can only operate in connection with signal converter UFC 030. See price list page 08.Required data in case of order: fluid - operating pressure - temperature of fluid - measuring range

Finish (V-Pos 16): KROHNE offshore paint, silver

Calibration (V-Pos 8): 3 points according to MID MI-004, EN1434-5Option

250 / 10" € 150€ 290300 / 12"

200 / 8" € 50

100 / 4" € 50

€ 226€ 283

150 / 6" € 50

100 / 4"

125 / 5" € 50

€ 226

80 / 3" € 0

DN "3"

€ 170125 / 5"

€ 283€ 350

300 / 12" € 423

€ 226150 / 6"

Option

€ 170

DN

€ 170

"C""3"

80 / 3" € 170

€ 226200 / 8"

€ 350€ 423

250 / 10"

Page 6: Price list 2009 Ultrasonic - Flowmeters Index SOME ... ISE... · Price list 2009 Ultrasonic - Flowmeters Index Rev.00 SOME INFORMATION ... Our QA System is approved according to DIN

Price list 2009 Ultrasonic flowmeter system UFM 3030: Page 05 Rev.00

Sensor UFS 3000, triple beam version UFS 3000for connection to flow converter UFC 030 DN 350 - 2000 / 14" - 80"

Base priceCode SensorVN53 4 Nominal diameter

H UFS 3000 DN 350 / 14" 0 K UFS 3000 DN 400 / 16" 0

L UFS 3000 DN 450 / 18" 0M UFS 3000 DN 500 / 20" 0N UFS 3000 DN 600 / 24" 0P UFS 3000 DN 700 / 28" 0

R UFS 3000 DN 800 / 32" 0S UFS 3000 DN 900 / 36" 0T UFS 3000 DN 1000 / 40" 0U UFS 3000 DN 1200 / 48" 0V UFS 3000 DN 1400 / 56" 0W UFS 3000 DN 1600 / 64" 0X UFS 3000 DN 1800 / 72" 0

Y UFS 3000 DN 2000 / 80" 0Nominal pressure Price adder

1 PN 6 EN 1092-1 ( DN 1200 - DN 2000 ) 02 PN 10 EN 1092-1 ( DN 350 - DN 1000 ) see page 073 PN 16 EN 1092-1 ( DN 350 - DN 2000 ) see page 074 PN 25 EN 1092-1 ( DN 350 - DN 2000 ) see page 07A ASME 150 lb RF ** ( DN 14" - DN 60" ) see page 07B ASME 300 lb RF ** ( DN 14" - DN 60" ) see page 07D ASME 600 lb RF ** ( DN 14" - DN 60" ) see page 07

Design / protection class / max. medium temperature1 compact with UFC 030 K / IP 67 - 140 °C / 282 °F 02 separate with UFC 030 F / IP 67 - 180 °C / 356 °F 03 separate with UFC 030 F / IP 68 - 180 °C / 356 °F ( not FM, CSA & TIIS approved ) 0A compact with UFC 030 K / IP 67 - 140 °C / 282 °F, prepared for stainless steel converter housing 0B separate with UFC 030 F / IP 67 - 180 °C / 356 °F, with stainless steel connection box 0

Approval0 without 01 EEx zone 1 03 FM Class I DIV 1 ( USA ) 04 FM Class I DIV 2 ( USA ) 06 CSA Class I DIV 1 ( Canada ) 07 CSA Class I DIV 2 ( Canada ) 0A TIIS ( Japan ) 0B CSA Class I DIV 1 ( Dual seal ) 0C CSA Class I DIV 2 ( Dual seal ) 0

Cable connection1 at converter ( compact version ) 03 2 x 1/2" NPT ( separate version ) 04 2 x PF 1/2" ( separate version ) 05 2 x M20 x 1,5 ( separate version ) 0

Tube- / flange material2 SS 316 L / SS 316 L slip on version see page 073* steel / steel slip on version Standard for DIN / JIS see page 07B SS 316 L / SS 316 L butt weld version see page 07C* steel / steel butt weld version Standard for ASME see page 07

Cable0* standard ( compact none, separate 5 m ) 01 10 m ( separate version ) 02 15 m ( separate version ) 03 20 m ( separate version ) 04 25 m ( separate version ) 05 30 m ( separate version ) 0

Calibration0* 2 points with water 02 3 points with water acc. RVA 03 3 points acc. to EN1434-5 / MID-004 ( DN 350 / 400 / 500 / 800 ) see page 066 6 points with water, 1 point with 3 results ( 2 repeats ) 07 6 points with water bidirectional, 2 points with 3 results ( 2 repeats for 2 points ) 0

Finish1* KROHNE standard, silver ( RAL 9006 ) 03 KROHNE offshore paint system, silver ( RAL 9006 ) see page 06A KROHNE standard + 304 / 1.4301 tagplate ( 67 x 25 mm ) 0C KROHNE offshore + 304 / 1.4301 tagplate ( 67 x 25 mm ) see page 06

Page 7: Price list 2009 Ultrasonic - Flowmeters Index SOME ... ISE... · Price list 2009 Ultrasonic - Flowmeters Index Rev.00 SOME INFORMATION ... Our QA System is approved according to DIN

Page 06 Rev.00

UFS 3000

VN53 4 0 0 0 Custody Transfer ( non mentioned sizes are on request ) Price adder0* Without 05 Water - hot, acc EN1434-4 CH ( DN 350 & 400 ) 06 Water - hot, acc EN1434-4 GE ( DN 350 & 400 ) 0K Water - hot, acc MI-004 EU ( DN 350 / 400 / 500 / 800 ) 0

Construction Requirements ( see page 09 )0* Standard 01 Group 1, gen. arr. drawing ( dimensions ) 02 Group 2, detailed prod. planning 03 Group 3, welding book 04 Group 4, stress calculations 0

QA/QC Requirements ( see page 09 )0* without 01 Group 1, decl. of compliance 2.1 02 Group 2, test.report 2.2 ( press. test ) 03 Group 3, insp. cert. EN 10204-3.1 ( press. test ) 04 Group 4, list of material certificates 05 Group 5, insp.& test plan ( QA checklist ) 06 Group 6, liquid (dye) penetration for all welds *** on request7 Group 7, X-ray ( incl. dye pen.) *** on request8 Group 8, PMI ( incl. dye pen. + X-ray ) *** on request

* Standard*** In preparation / pending.

VN53 4 0 0 0 Complete ordering code Higher pressure rating / other flange materials on request

Sensor UFS 3000 can only operate in connection with signal converter UFC 030. See price list page 08.Required data in case of order: fluid - operating pressure - temperature of fluid - measuring rangeRemark

** ASME B 16.5 150 / 300 / 600 lb RF / RTJ : for DN 14 - 24"ASME B 16.47 A 150 / 300 / 600 lb RF : for DN 28 - 60"ASME B 16.47 A 600 lb RTJ : for DN 28 - 36"

Finish (V-Pos 16): KROHNE offshore paint, silver

Calibration (V-Pos 8): 3 points according to MID MI-004, EN1434-5Option

500 / 20" 0

800 / 32" 0

600 / 24" on request 700 / 28" on request

400 / 16" 0 450 / 18" on request

350 / 14" 0

DN "3"

2000 / 80" on request on request

1600 / 64" on request on request1800 / 72" on request on request

1200 / 48" on request on request1400 / 56" on request on request

900 / 36" 0 01000 / 40" 0 0

700 / 28" 0 0 800 / 32" 0 0

500 / 20" 0 0 600 / 24" 0 0

400 / 16" 0 0 450 / 18" 0 0

350 / 14" 0 0

DN "3" "C"Option

Page 8: Price list 2009 Ultrasonic - Flowmeters Index SOME ... ISE... · Price list 2009 Ultrasonic - Flowmeters Index Rev.00 SOME INFORMATION ... Our QA System is approved according to DIN

Price list 2009 Page 07 Rev.00

Options UFS 3000Non standard pressure ratings DIN / ASME

Flangematerial: carbon steel PN PN

DN PN 10 PN 16 PN 25 PN 40 10 K 20 K DN 150 lb 300 lb 600 lb

80 Standard Standard Special 3" Standard 0 0100 Standard 0 0 Standard Special 4" Standard 0 0125 Standard 0 0 Standard Special 5" Standard 0 0150 Standard 0 0 Standard Special 6" Standard 0 0200 Standard 0 0 0 Standard Special 8" 0 0 0250 Standard 0 0 0 Standard Special 10" 0 0 0300 Standard 0 0 0 Standard Special 12" 0 0 0350 Standard 0 0 0 Special Special 14" 0 0 0400 Standard 0 0 0 Special Special 16" 0 0 0450 Standard 0 0 0 Special Special 18" 0 0 0500 Standard 0 0 0 Special Special 20" 0 0 0600 Standard 0 0 0 Special Special 24" 0 0 0

Flangematerial: stainless steel DIN 1.4404 / ASME 316 L PN PN

DN PN 10 PN 16 PN 25 PN 40 10 K 20 K DN 150 lb 300 lb 600 lb

25 Standard Standard 1" Standard 0 032 Standard Standard 1 1/4" Standard 0 040 Standard Standard 1 1/2" Standard 0 050 Standard Standard 0 2" Standard 0 065 Standard Standard 0 2 1/2" Standard 0 080 0 0 Special 3" 0 0 0100 0 0 0 0 Special 4" 0 0 0125 0 0 0 0 Special 5" 0 0 0150 0 0 0 0 Special 6" 0 0 0200 0 0 0 0 0 Special 8" 0 0 0250 0 0 0 Special 0 Special 10" 0 0 0300 0 0 0 Special 0 Special 12" 0 0 0

350 *** 0 Special Special Special Special Special 14" *** 0 0 0400 *** 0 Special Special Special Special Special 16" *** 0 0 0450 *** 0 Special Special Special Special Special 18" *** 0 0 0500 *** 0 Special Special Special Special Special 20" *** 0 0 0600 *** 0 Special Special Special Special Special 24" *** 0 0 0

ASME

ASME

DIN

DIN

JIS

JIS

Page 9: Price list 2009 Ultrasonic - Flowmeters Index SOME ... ISE... · Price list 2009 Ultrasonic - Flowmeters Index Rev.00 SOME INFORMATION ... Our QA System is approved according to DIN

*** The price adder for these sizes is including ASME 316 L / DIN 1.4404 tube material.Feature tube / flange material option codes: - B for ASME and 0

- 2 for DIN / JIS.Please note: for DN > 700 / 28" the price adder is "on request" .

Flangematerial: stainless steel DIN 1.4404 / ASME 316 LPN

DN PN 63 PN 100

25 0 032 0 040 0 050 0 065 0 0

DIN

Page 10: Price list 2009 Ultrasonic - Flowmeters Index SOME ... ISE... · Price list 2009 Ultrasonic - Flowmeters Index Rev.00 SOME INFORMATION ... Our QA System is approved according to DIN

Price list 2009 Ultrasonic flowmeter system UFM 3030: Page 08 Rev.00

Flow converter UFC 030, including HART UFC 030for connection to sensor UFS 3000

Base priceCode Flow converterVN50 4 Type

1 UFC 030 K Batch compact version 0 2 UFC 030 K Batch MP compact version MP-version standard for Ex-version 0 4 UFC 030 F Batch field version 0 5 UFC 030 F Batch MP field version MP-version standard for Ex-version 0

7 UFC 030 K i MP compact version MP-version standard for Ex-version 08 UFC 030 F i MP field version MP-version standard for Ex-version 0A UFC 030 K Temperature + Pressure compact version 0B UFC 030 K Temperature + Pressure MP compact version MP-version standard for Ex-version 0D UFC 030 F Temperature + Pressure field version 0E UFC 030 F Temperature + Pressure MP field version MP-version standard for Ex-version 0

Power supply Price adder4 24 V AC / DC 0D 100 - 240 V AC 0

Approval0 without 01 EEx zone 1 "d" ( terminal compartment "d" ) 02 EEx zone 1 "e" ( terminal compartment "e" ) 03 FM Class I DIV 1 ( USA ) 04 FM Class I DIV 2 ( USA ) 06 CSA Class I DIV 1 ( Canada ) 07 CSA Class I DIV 2 ( Canada ) 0A TIIS ( Japan ) 0B CSA Class I DIV 1 ( Dual seal ) 0C CSA Class I DIV 2 ( Dual seal ) 0

Ex-i output0 Without 01 Ex-i 1 mA (passive) + HART + Binary input / output (passive) 02 Ex-i 2 mA (passive) + Profibus PA / HART 0B i 2 mA (passive) + Profibus PA / HART (non-EEx) 0

Operating manual / Operation language 1 German / german 0 2 English GB / english 0

3 English US / english 04 French / french 0

Cable connection2 2 x 1/2" NPT 03 2 x PF 1/2 04* 2 x M20 x 1,5 0

Page 11: Price list 2009 Ultrasonic - Flowmeters Index SOME ... ISE... · Price list 2009 Ultrasonic - Flowmeters Index Rev.00 SOME INFORMATION ... Our QA System is approved according to DIN

Converter housing1* Die-cast aluminum 02 St. st. 1.4404 ( for compact version ) 02 St. st. 1.4404 ( for field version ) 06 Die-cast aluminum with offshore paint 07 St. st. 1.4404 with offshore paint ( for compact version ) 07 St. st. 1.4404 with offshore paint ( for field version ) 0

Custody Transfer0* Without 05 Water - hot, acc. EN1434-4 CH ( MP version & 100 - 240 V AC only ) 06 Water - hot, acc. EN1434-4 GE ( MP version & 100 - 240 V AC only ) 0K Water - hot, acc. MI-004 EU class 2 ( MP version & 100 - 240 V AC only ) 0L Water - hot, acc. MI-004 EU class 3 ( MP version & 100 - 240 V AC only ) 0

Output signal0* Standard 01 acc. NAMUR NE 43 ( Ex version only, not for CSA) 0

Tagplate0* standard, without 01 304 / 1.4301 tagplate ( 67 x 25 mm ) 0

* Standard*** In preparation / pending.

VN50 4 0 0 Complete ordering code

Required data in case of order: measuring range - signal output 0 or 4 ... 20 mA - pulse output 1 P.= ...l or m³

Page 12: Price list 2009 Ultrasonic - Flowmeters Index SOME ... ISE... · Price list 2009 Ultrasonic - Flowmeters Index Rev.00 SOME INFORMATION ... Our QA System is approved according to DIN

Price list 2009 Ultrasonic flowmeter system UFM 3030: Page 09 Rev.00

Content of documentation packages UFS 3000DN 25 - 2000 / 1" - 80"

Construction requirements Option 0 1 2 3 4Standard documentation, which includes at delivery:Condensed installation and operating manual x x x x xInstallation and operating instructions for use in hazardous areas (for Ex units only) x x x x xService handbook on CD x x x x xCalibration certificate x x x x xOptional documentation: Option 0 1 2 3 4General arrangement drawing in pdf format (not to scale).* 1) x x x xDetailed production planning.* 1) x x xWelding book, which includes the following documents: 1) x x

- General Arrangement Drawings (flow tube assembly) with welds identification.- WPS (Welding Plan Specification), which describes the main parameters of welding and create the links with PQR.- PQR (Procedure Qualification Record) are performed according to the European or American Standards (EN 288 or EN 15614 or ASME IX) by authorized laboratories.- WQ (Welder's Qualification) are performed according to the Standards (EN 287 or EN 1418 or ASME IX).

Stress calculation according to DIN 2413 or 2505 or ASME. 1) x

* Delivery 2 weeks after receipt of order at KROHNE Altometer.

QA / QC requirements Option 1 2 3 4 5 6 7 8Declaration of Compliance according to EN 10204, 2.1 1) x x x x x x x xTest report including pressure test according to EN 10204, 2.2 ** 1) x x x x x x xInspection Certificate according to EN 10204, 3.1 ** 1) x x x x x xMaterial certificates of the pressure retaining parts according to EN 10204, 3.1 1) x x x x xInspection - and test plan (Quality checklist) 1) x x x xLiquid (Dye) Penetrant examination for all welds [EN 571-1 / ASME V SE-165 (art.6)] + coating report 2) x x xX-ray for flange / tube butt welds [EN 1435 / ASME V] 2) x xPositive Material Identification (PMI) 2) x

** One certificate, which is also applicable for the former option(s). Group 2: 2.2 certificate is also valid as 2.1. Group 3: 3.1 certificate is also valid as 2.2 & 2.1.

Remarks1) The price of this option is per order position.2) The price of this option is per instrument.

Page 13: Price list 2009 Ultrasonic - Flowmeters Index SOME ... ISE... · Price list 2009 Ultrasonic - Flowmeters Index Rev.00 SOME INFORMATION ... Our QA System is approved according to DIN

Price list 2009 Ultrasonic flowmeter system UFM 530: Page 10 Rev.00

Sensor UFS 500, single channel version. UFS 500 HTHT (high temperature) DN 25 - 80 / 1" - 3"for connection to flow converter UFC 030 F

Base priceCode SensorV394 4 Nominal diameter

4 UFS 500 HT DN 25 / 1" 0 5 UFS 500 HT DN 32 / 1 1/4" 0 6 UFS 500 HT DN 40 / 1 1/2" 0 7 UFS 500 HT DN 50 / 2" 0

A UFS 500 HT DN 80 / 3" 0Nominal pressure Price adder

5 PN 40 EN 1092-1 06 PN 63 EN 1092-1 on request7 PN 100 EN 1092-1 on requestA ASME B 16.5 150 lb RF 0B ASME B 16.5 300 lb RF on requestD ASME B 16.5 600 lb RF on requestE ASME B 16.5 900 lb RF on requestN JIS 10K on request

Operating instruction0 without 02 English GB 03 English US 0

Approval0 without 01 EEx zone 1 04 FM Class I DIV 1 ( USA ) 0B CSA Class I DIV 1 ( Dual seal ) 0

Cable connection3 2 x adaptor 1/2" NPT (F) ( separate version ) 04 2 x adaptor PF 1/2" (F) ( separate version ) 05 2 x adaptor M20 x 1,5 (F) ( separate version ) 0

Material: pipe / flange sensor - window / type / prot. category / temp. of fluidD* SS 316 L / SS 316 L ( ASME, JIS, DIN ) SS 316 / F / IP 65 / 500 °C 0

* Standard*** In preparation / pending.

V394 4 D 0 0 0 0 0 Complete ordering code

Sensor UFS 500 HT can only operate together with signal converter UFC 030 F. See price list page 08.Required data in case of order: fluid - operating pressure - temperature of fluid - measuring range

signal cable UFM 500 F HT XN00 10 41- 0 see spare parts Price list 2009armored signal cable UFM 500 F HT see spare parts Price list 2009XN00 10 42- 0

Page 14: Price list 2009 Ultrasonic - Flowmeters Index SOME ... ISE... · Price list 2009 Ultrasonic - Flowmeters Index Rev.00 SOME INFORMATION ... Our QA System is approved according to DIN

Price list 2009 Ultrasonic flowmeter system UFM 530: Page 11 Rev.00

Sensor UFS 500, dual channel version. UFS 500 HTHT (high temperature) DN 100 - 300 / 4" - 12"for connection to flow converter UFC 030 F

Base priceCode SensorV395 4 Nominal diameter

B UFS 500 HT DN 100 / 4" 0 D UFS 500 HT DN 150 / 6" 0 E UFS 500 HT DN 200 / 8" 0 F UFS 500 HT DN 250 / 10" 0

G UFS 500 HT DN 300 / 12" 0Nominal pressure Price adder

2 PN 10 EN 1092-1 ( DN 200 - DN 300 ) 03 PN 16 EN 1092-1 ( DN 100 - DN 150 ) 0A ASME B 16.5 150 lb RF 0

Operating instruction0 without 02 English GB 03 English US 0

Approval0 without 01 EEx zone 1 04 FM Class I DIV 1 ( USA ) 0B CSA Class I DIV 1 ( Dual seal ) 0

Cable connection3 2 x adaptor 1/2" NPT (F) ( separate version ) 04 2 x adaptor PF 1/2" (F) ( separate version ) 05 2 x adaptor M20 x 1,5 (F) ( separate version ) 0

Material: pipe / flange sensor - window / type / prot. category / temp. of fluidD* SS 316 L / SS 316 L ( ASME, JIS, DIN ) SS 316 / F / IP 65 / 500 °C 0

* Standard*** In preparation / pending.

V395 4 D 0 0 0 0 0 Complete ordering code

Sensor UFS 500 HT can only operate together with signal converter UFC 030 F. See price list page 08.Required data in case of order: fluid - operating pressure - temperature of fluid - measuring range

signal cable UFM 500 F HT XN00 10 41- 0 see spare parts Price list 2009armored signal cable UFM 500 F HT see spare parts Price list 2009XN00 10 42- 0

Page 15: Price list 2009 Ultrasonic - Flowmeters Index SOME ... ISE... · Price list 2009 Ultrasonic - Flowmeters Index Rev.00 SOME INFORMATION ... Our QA System is approved according to DIN

Price list 2009 Ultrasonic flowmeter system OPTISONIC 6300: Page 12 Rev.00

Sensor OPTISONIC 6000, clamp on. OPTISONIC 6000DN 15 - 4000 / 1/2" - 160"

for connection to flow converter UFC 300

Base priceCode SensorVN60 4 Nominal diameter

2 OPTISONIC 6000 - small DN 15 / 1/2" - DN 100 / 4" 07 OPTISONIC 6000- medium DN 50 / 2" - DN 400 / 16" 0E OPTISONIC 6000 - large DN 200 / 8" - DN 4000 / 160" 0

Version Price adder0 Standard, max. 120°C / 248°F 0

Approval0 Without 01 EEx zone 1 ( only with UFC 300 F ) 04 FM Class 1 DIV 1 ( only with UFC 300 F ) 05 FM Class 1 DIV 2 ( only with UFC 300 F ) 0B CSA Class 1 DIV 1 ( only with UFC 300 F ) 0C CSA Class 1 DIV 2 ( only with UFC 300 F ) 0

Design / cable connection7 separate with UFC 300 / M16 x 1.5 0

Converter0 Without 0D UFC 300 F ( field mount version ) 0E UFC 300 W ( wall mount version ) 0

Rail- / cover material0* Aluminum / Aluminum 01 316 (L) / without cover ( only for small ) 01 316 (L) / without cover ( only for medium ) 0

Cable length0* 5 m - 15 ft 01 10 m - 30 ft 02 15 m - 45 ft 03 20 m - 60 ft 04 25 m - 75 ft 05 30 m - 90 ft 0

Calibration0* Standard, including calibration of transducer pair 03 Verification of the system using a reference tube DN 100 ( not for large, DN 200 / 8" - 4000 / 160" ) 03 Verification of the system using a reference tube DN 1000 ( only for large, DN 200 / 8" - 4000 / 160" ) 0

Finish1* KROHNE standard, silver ( RAL 9006 ) 0A KROHNE standard + 304 / 1.4301 tagplate ( 67 x 25 mm ) 0

Protection class0 IP 67 0

Construction requirements0* Standard 0

QA / QC requirements

Page 16: Price list 2009 Ultrasonic - Flowmeters Index SOME ... ISE... · Price list 2009 Ultrasonic - Flowmeters Index Rev.00 SOME INFORMATION ... Our QA System is approved according to DIN

0* Standard 0Instruction manual language ( sensor only )

0* Without, for UFC 300 F / W 01 German ( sensor only ) 02 English GB ( sensor only ) 03 English US ( sensor only ) 04 French ( sensor only ) 0

* Standard*** In preparation / pending

VN60 4 0 7 0 0 0 0 0 0 0 0 Complete ordering code

Sensor OPTISONIC 6000 can only operate in connection to flow converter UFC 300. See page 13-14.

Page 17: Price list 2009 Ultrasonic - Flowmeters Index SOME ... ISE... · Price list 2009 Ultrasonic - Flowmeters Index Rev.00 SOME INFORMATION ... Our QA System is approved according to DIN

Price list 2009 Ultrasonic flowmeter system OPTISONIC 6300: Page 13a Rev.00

Flow converter UFC 300 CO, UFC 300 COonly for sensor OPTISONIC 6000 (clamp on).

Basic version Base price

Code flow converterVN32 4 Type

H UFC 300 CO F, die-cast aluminum field housing with local display 0N UFC 300 CO W, polyamide wall housing with local display 0

Power supply Price adder4 24 V DC / AC ( 19 - 29 V ) 0A 100 - 230 V AC ( 85 - 250 V AC, 50/60 Hz ) 0

Ex-version0 without - non Ex 01 EEx zone 1 ( terminal compartment "d" - F ) 02 EEx zone 1 ( terminal compartment "e" - F ) 04 FM Class 1 DIV 1 05 FM Class 1 DIV 2 0B CSA Class 1 DIV 1 0C CSA Class 1 DIV 2 0

Cable connection4 3 x 1/2" NPT 05 3 x PF 1/2" 06 3 x M20 x 1,5 0

Instruction manual / Operating language1 German / german 02 English GB / english GB 03 English US / english US 04 French / french 05 Without / german 06 Without / english GB 07 Without / french 08 Without / spanish 0

Custody transfer0* Without 0

Process diagnostics5* Clamp on - Co 0

Converter housing1 Standard 02 St.steel 1.4408 ( for Field ) 0

Page 18: Price list 2009 Ultrasonic - Flowmeters Index SOME ... ISE... · Price list 2009 Ultrasonic - Flowmeters Index Rev.00 SOME INFORMATION ... Our QA System is approved according to DIN

Page 14a Rev.00

UFC 300 CO

VN32 4 0 5 Communication Price adder1* Basic IO ( 4-20 mA / HART + pulse / frequency + status + control ) 0

1-st IO Module0* Without, no module possible 0

2-nd IO Module0* Without, no module possible 0

Configuration of sensor0* Single path/pipe for 1 OPTISONIC 6000 sensor 01 Dual path/pipe for 2 OPTISONIC 6000 sensors 0

Tagplate0* Standard, without 01 304 / 1.4301 tagplate ( 67 x 25 mm ) 0

* Standard*** In preparation / pending.

VN32 4 0 5 0 1 0 0 0 Complete ordering code

Page 19: Price list 2009 Ultrasonic - Flowmeters Index SOME ... ISE... · Price list 2009 Ultrasonic - Flowmeters Index Rev.00 SOME INFORMATION ... Our QA System is approved according to DIN

Price list 2009 Ultrasonic flowmeter system OPTISONIC 6300: Page 13b Rev.00

Flow converter UFC 300 CO, UFC 300 COonly for sensor OPTISONIC 6000 (clamp on).

Ex-i version Base price

Code flow converterVN32 4 Type

H UFC 300 CO F, die-cast aluminum field housing with local display 0N UFC 300 CO W, polyamide wall housing with local display 0

Power supply Price adder4 24 V DC / AC ( 19 - 29 V ) 0A 100 - 230 V AC ( 85 - 250 V AC, 50/60 Hz ) 0

Ex-version0 without - non Ex 01 EEx zone 1 ( terminal compartment "d" - F ) 02 EEx zone 1 ( terminal compartment "e" - F ) 04 FM Class 1 DIV 1 05 FM Class 1 DIV 2 0B CSA Class 1 DIV 1 0C CSA Class 1 DIV 2 0

Cable connection4 3 x 1/2" NPT 05 3 x PF 1/2" 06 3 x M20 x 1,5 0

Instruction manual / Operating language1 German / german 02 English GB / english GB 03 English US / english US 04 French / french 05 Without / german 06 Without / english GB 07 Without / french 08 Without / spanish 0

Custody transfer0* Without 0

Process diagnostics5* Clamp on - Co 0

Converter housing1 Standard 02 St.steel 1.4408 ( for Field ) 0

Page 20: Price list 2009 Ultrasonic - Flowmeters Index SOME ... ISE... · Price list 2009 Ultrasonic - Flowmeters Index Rev.00 SOME INFORMATION ... Our QA System is approved according to DIN

Page 14b Rev.00

UFC 300 CO

VN32 4 0 5 Communication Price adder2 Ex-i IO: CO a + PO pas. (Cur. Out.-active + Pulse Out.-passive) 03 Ex-i IO: CO p + PO pas. (Cur. Out.-passive+ Pulse Out.-passive) 0

1-st IO Module0* Without, no module possible 01 Ex-i IO: CO act. + PO / CI pas. (CO-active+PO/Control Input-pas.) 02 Ex-i IO: CO pas. + PO / CI pas. (CO-pas.+ PO/Control Input-pas.) 0

2-nd IO Module0* Without, no module possible 0

Configuration of sensor0* Single path/pipe for 1 OPTISONIC 6000 sensor 01 Dual path/pipe for 2 OPTISONIC 6000 sensors 0

Tagplate0* Standard, without 01 304 / 1.4301 tagplate ( 67 x 25 mm ) 0

* Standard*** In preparation / pending.

VN32 4 0 5 0 0 0 Complete ordering code US $

10 11 12 10 11 122 0 0 3 0 0

1 0 1 02 0 2 0

Ex-i I/OEx-i I/O

Page 21: Price list 2009 Ultrasonic - Flowmeters Index SOME ... ISE... · Price list 2009 Ultrasonic - Flowmeters Index Rev.00 SOME INFORMATION ... Our QA System is approved according to DIN

Price list 2009 Ultrasonic flowmeter system OPTISONIC 6300: Page 13c Rev.00

Flow converter UFC 300 CO, UFC 300 COonly for sensor OPTISONIC 6000 (clamp on).

Modular version Base price

Code flow converterVN32 4 Type

H UFC 300 CO F, die-cast aluminum field housing with local display 0N UFC 300 CO W, polyamide wall housing with local display 0

Power supply Price adder4 24 V DC / AC ( 19 - 29 V ) 0A 100 - 230 V AC ( 85 - 250 V AC, 50/60 Hz ) 0

Ex-version0 without - non Ex 01 EEx zone 1 ( terminal compartment "d" - F ) 02 EEx zone 1 ( terminal compartment "e" - F ) 04 FM Class 1 DIV 1 05 FM Class 1 DIV 2 0B CSA Class 1 DIV 1 0C CSA Class 1 DIV 2 0

Cable connection4 3 x 1/2" NPT 05 3 x PF 1/2" 06 3 x M20 x 1,5 0

Instruction manual / Operating language1 German / german 02 English GB / english GB 03 English US / english US 04 French / french 05 Without / german 06 Without / english GB 07 Without / french 08 Without / spanish 0

Custody transfer0* Without 0

Process diagnostics5* Clamp on - Co 0

Converter housing1 Standard 02 St.steel 1.4408 ( for Field ) 0

Page 22: Price list 2009 Ultrasonic - Flowmeters Index SOME ... ISE... · Price list 2009 Ultrasonic - Flowmeters Index Rev.00 SOME INFORMATION ... Our QA System is approved according to DIN

Page 14c Rev.00

UFC 300 CO

VN32 4 0 5 Communication Price adder4 Module IO: CO a + PO act./hc (CO-active+PO-active/high current) 06 Module IO: CO a + PO pas./hc (CO-active+PO-passive/high cur.) 07 Module IO: CO a + PO pas./Na (CO-active+PO-passive/Namur) 08 Module IO: CO p + PO act./hc (CO-passive+PO-active/high cur.) 0B Module IO: CO p + PO pas./hc (CO-passive+PO-passive/high cur.) 0C Module IO: CO p + PO pas./Na (CO-passive+PO-passive/Namur) 0

1-st IO Module0* Without, no module possible 08 Without IO module 0A Current Output - active 0B Current Output - passive 0C Pulse Output - active / high current 0E Pulse Output - passive / high current 0F Pulse Output - passive / Namur 0G Control Input - active / high current 0H Control Input - active / Namur 0K Control Input - passive / high current 0

2-nd IO Module0* Without, no module possible 08 Without IO module 0A Current Output - active 0B Current Output - passive 0C Pulse Output - active / high current 0E Pulse Output - passive / high current 0F Pulse Output - passive / Namur 0G Control Input - active / high current 0H Control Input - active / Namur 0K Control Input - passive / high current 0

Configuration of sensor0* Single path/pipe for 1 OPTISONIC 6000 sensor 01 Dual path/pipe for 2 OPTISONIC 6000 sensors 0

Tagplate0* standard, without 01 304 / 1.4301 tagplate ( 67 x 25 mm ) 0

* Standard*** In preparation / pending.

VN32 4 0 5 0 0 Complete ordering code US $

10 11 12 10 11 12 10 11 12 10 11 12 10 11 12 10 11 124 8 8 6 8 8 7 8 8 8 8 8 B 8 8 C 8 8

A 8 A 8 A 8 B 8 B 8 B 8A A A B B BC E F C E FG K H G K H

C 8 E 8 F 8 C 8 E 8 F 8C E F C E FG K H G K H

G 8 K 8 H 8 G 8 K 8 H 8G H H G K H

Modular I/O Modular I/O Modular I/O Modular I/O Modular I/OModular I/O

Page 23: Price list 2009 Ultrasonic - Flowmeters Index SOME ... ISE... · Price list 2009 Ultrasonic - Flowmeters Index Rev.00 SOME INFORMATION ... Our QA System is approved according to DIN

Price list 2009 Clamp-on ultrasonic flowmeter: Page 15 Rev.00

UFM 610 P (portable system), suitable for pipes DN 13 - 5000 / 1/2 - 200" UFM 610 PStandard supplied with sensor types A and B (max. 200 °C / 392 °F), Battery operated, charger voltage 90 - 250 Volt (50/60 Hz)Accuracy + 2 % of actual flowrate

Base priceCode SensorV381 4 Type

UFC 610 P 0A sensors ( 13 to 89 mm, 1/2" to 3 1/2" ) Price adder

2 -20 to 200 °C / -4 to 392 °F, including guide rail ( chain strap ) 0B sensors ( 90 to 1000 mm, 3 1/2" to 40" )

5 -20 to 200 °C / -4 to 392 °F, including guide rail ( chain ) 06 -20 to 200 °C / -4 to 392 °F, including guide rail ( magnets & ratchets ) 0

C sensors ( 300 to 2000 mm, 12" to 80" )0 Without 02 -20 to 200 °C / -4 to 392 °F, excluding guide rail 05 -20 to 200 °C / -4 to 392 °F, including guide rail (chain) 06 -20 to 200 °C / -4 to 392 °F, including guide rail ( magnets & ratchets ) 0

D sensors ( 1000 to 5000 mm, 40" to 200" )0 Without 01 0 to 80 °C / 32 to 176 °F, including guide rail, ratchets, straps and cables 0

Operating instruction / Programming language0 Without 01 German 02 English GB 03 English US 04 French 0

* Standard*** In preparation / pending.

V381 4 2 0 0 0 0 0 Complete ordering code

Page 24: Price list 2009 Ultrasonic - Flowmeters Index SOME ... ISE... · Price list 2009 Ultrasonic - Flowmeters Index Rev.00 SOME INFORMATION ... Our QA System is approved according to DIN

Price list 2009 Ultrasonic flowmeter system OPTISONIC 7060: Page 16 Rev.00

Sensor OPTISONIC 7000, double channel version. OPTISONIC 7000Single channel version for DN 50 & 65 / 2" & 2 1/2". DN 50 - 600 / 2" - 24"for connection to flow converter GFC 060

Base priceCode SensorVN72 4 Nominal diameter

7 OPTISONIC 7000 DN 50 / 2" ** single channel version 08 OPTISONIC 7000 DN 65 / 2 1/2" ** single channel version 0A OPTISONIC 7000 DN 80 / 3" 0B OPTISONIC 7000 DN 100 / 4" 0C OPTISONIC 7000 DN 125 / 5" 0D OPTISONIC 7000 DN 150 / 6" 0E OPTISONIC 7000 DN 200 / 8" 0F OPTISONIC 7000 DN 250 / 10" 0G OPTISONIC 7000 DN 300 / 12" 0H OPTISONIC 7000 DN 350 / 14" 0K OPTISONIC 7000 DN 400 / 16" 0L OPTISONIC 7000 DN 450 / 18" 0M OPTISONIC 7000 DN 500 / 20" 0N OPTISONIC 7000 DN 600 / 24" 0

Nominal pressure Price adder2 PN 10 EN 1092-1 ( DN 200 - DN 600 ) 03 PN 16 EN 1092-1 ( DN 100 - DN 150 ) 05 PN 40 EN 1092-1 ( DN 50 - DN 80 ) 0A ASME B 16.5 150 lb RF see page 18B ASME B 16.5 300 lb RF see page 18D ASME B 16.5 600 lb RF ( < DN 12" ) see page 18

Approval0 Without 01 EEx Zone 1 0B CSA Class I Div.1 Groups B, C, D 0C CSA Class I Div.2 Groups A, B, C, D 0

Design / protection class1 Compact with GFC 060 C - alu converter housing / IP 67 - NEMA 4X/6 02 Compact with GFC 060 C - high temperature vers. / IP 67 - NEMA 4X/6 0

ConverterH GFC 060 C ( compact design ) 0

Tube- / flange materialB 316 (L) / 316 (L) see page 18C* Steel / Steel see page 18

Calibration0* Calibration with air, atm. pressure 0

Finish1* KROHNE standard, silver ( RAL 9006 ) 0

Sensor frequency0* 135 kHz 0

Construction requirements

Page 25: Price list 2009 Ultrasonic - Flowmeters Index SOME ... ISE... · Price list 2009 Ultrasonic - Flowmeters Index Rev.00 SOME INFORMATION ... Our QA System is approved according to DIN

0* Standard 0QA / QC requirements

0* Standard 0Material of sensor / pressure rating

0* Titanium 0Sensor gasket material

0* Viton (standard) 0Instruction manual language

1 German 02 English GB 03 English US 04 French 0

* Standard*** In preparation / pending.

VN72 4 H 0 0 0 0 1 0 0 0 0 0 0 Complete ordering code

Sensor OPTISONIC 7000 can only operate in connection to signal converter GFC 060. See page 17.

Required data in case of order: medium - operating pressure - temperature of medium - measuring range - viscosity - density.

Page 26: Price list 2009 Ultrasonic - Flowmeters Index SOME ... ISE... · Price list 2009 Ultrasonic - Flowmeters Index Rev.00 SOME INFORMATION ... Our QA System is approved according to DIN

Price list 2009 Ultrasonic flowmeter system OPTISONIC 7060: Page 17 Rev.00

Flow converter GFC 060 GFC 060for connection to sensor OPTISONIC 7000

Basic price included in sensor OPTISONIC 7000 price Code Flow converterVN71 4 Type

4 GFC 060 C ( compact design ) Power supply

1 24 V DC Approval

0 without 1 ATEX II 2G EEx de ib [ia] IIA T4 2 ATEX II 2G EEx de ib [ia] IIC T4 B CSA Class I Div.1 Groups B, C, D C CSA Class I Div.2 Groups A, B, C, D

Ex-i output0 Without

Instruction manual / - language 1 German / german 2 English GB / english 3 English US / english

4 French / french Cable connection

4 3 x adaptor 1/2" NPT 5 3 x adaptor PF 1/2" 6 3 x M20 x 1,5

Converter housing1* Die-cast aluminum

Finish1* KROHNE standard, silver ( RAL 9006 )

Process temperature0* Standard ( max. 100°C ) 1 Extended ( max. 180°C )

Tagplate0* standard, without 1 304 / 1.4301 tagplate ( 67 x 25 mm )

* Standard*** In preparation / pending.

VN71 4 4 1 0 1 0 1 0 Complete ordering code

Required data in case of order: measuring range - signal output 0 or 4 ... 20 mA - pulse output 1 P.= ...l or m³

Page 27: Price list 2009 Ultrasonic - Flowmeters Index SOME ... ISE... · Price list 2009 Ultrasonic - Flowmeters Index Rev.00 SOME INFORMATION ... Our QA System is approved according to DIN

Price list 2009 Page 18 Rev.00

Options OPTISONIC 7000Non standard pressure ratings price adders ASME

Flangematerial: carbon steel PN

DN 150 lb 300 lb 600 lb

2" Standard 0 02 1/2" Standard 0 0

3" Standard 0 04" Standard 0 05" Standard 0 06" Standard 0 08" Standard 0 010" Standard 0 012" Standard 0 014" 0 0 on request16" 0 0 on request18" 0 0 on request20" 0 0 on request24" 0 0 on request

Tube- / flangematerial: 316 L PN

DN 150 lb 300 lb 600 lb

2" 0 on request on request2 1/2" 0 on request on request

3" 0 on request on request4" 0 on request on request5" 0 on request on request6" 0 on request on request8" 0 on request on request10" 0 on request on request12" 0 on request on request14" 0 on request on request16" 0 on request on request18" 0 on request on request20" 0 on request on request24" 0 on request on request

ASME

ASME