feature benefits
Prestige 2com trunking is designed to meet the needsof current and future data cabling.
Prestige 2com is Cat 6 compliant and providesmaximum capacity for data cabling.
Cat 6 compliant50mm radius bends on all corners so cables lie in trunking correctly to avoidany deformation which may result in signal distortion and loss. Complieswith and exceeds Cat 5/5e wiring regulations. Ideal also for futurerefurbishments using upgraded computer cables – Cat 6E/7
Maximises capacity60mm deep trunking with two equal compartments to maximise datachannel cabling
Flexible accessoriesAccessories can be mounted on either or both compartments – enablesmaximum use of wiring space in one compartment
Frames maximise spaceMounting frames for LJU6/Euro data outlets to maximise use of space
Stylish and robustSingle piece end caps, corners and couplers for improved aesthetics andsolid construction. Screw fix option for security of fitting (corners)
Pre-drilled trunking basesEliminates the need to measure and drill fixing holes on site thus reducinginstallation time
range introduction
cable management | perimeter and distribution
Features
END CAPS
Neatly finish runs of
trunking. Supplied as sets
of right and left hand pairs
including retainers and
covers
One-piece cover simplifies
installation
MAIN CARRIER
Pre-drilled at 100mm centres for ease
and speed of installation
INTERNAL CORNER
One-piece cover simplifies
specification and
installation. Each assembly
is supplied with clip-on
cover and moulded corner
carrier
Data bend component with
50mm Radius
Screw fix option
Unobtrusive screw fixings
to maximise security
against tampering
AESTHETIC PROFILE
Stylish, contoured elegance
CABLE RETAINERS
Hold cables securely
in place
COVERS
Clip-on to complete
assembly and conceal
wiring
ACCESSORY MOUNTING BOXES AND FRAMESAll boxes have facility to ‘knockout’ back for greater depth.
35mm boxes for larger cabling size requirements, deep accessories,
data and power
Accessories can be mounted in either or both compartments
Features
cable management | perimeter and distribution
MINI TRUNKING
ADAPTORS
For cable
distribution to
and from Prestige
2com a range of
MK mini trunking
and Egatube
Conduit can be
used
CABLE DIVIDER
Sub-divides
internal
compartments
2 COMPARTMENTS
For maximum data
cable capacity
complete compartment
area can be used
EXTERNAL CORNER
One-piece cover component for ease of
assembly and styling. Each assembly is
supplied with clip-on cover and moulded
corner carriers.
Data bend component with 50mm
Radius.
Screw fix option
Unobtrusive screw fixings to maximise
security against tampering
COUPLER
One-piece cover
component for ease
of assembly. Each
assembly is supplied
with carrier moulding
and clip-on cover
(not shown above)
FLAT TEES AND ANGLES
These enable the Prestige 2com
trunking configuration to follow
the contours of the installation
in the vertical plane and include
50mm radius inserts to ensure
continued data cable protection
EMC SCREENING
Aluminium screening inserts
provide an effective screen
for computer service cables
and can be used in either
compartment
CROSSOVER
BRIDGE
Permits cabling to
cross from one
cable
compartment to
another within the
assembly, whilst
maintaining
segregation
CouplerAssembly
Lid Joint Cover
InternalCornerAssembly
CONSISTS OFCOVER ANDCARRIER
DIMENSIONS210 X 60MM
ExternalCornerAssemblyCONSISTS OFCOVER, CARRIERAND RADIUSINSERT
End CapCover andRetainer
Main Carrier
Straight Cover
End CapAssembly
CableRetainer
CrossoverBridge
MiniTrunkingAdaptor
TrunkingAdaptor50 X 50mm
VTS/2001 WHI3 METRE LENGTHS
VTS/2001 D1 WHI2 METRE LENGTHSFOR (NON UK) MARKETS
NOT SUPPLIED WITHLID (COVER)
4m
6m VTS/5 WHI3 METRE LENGTHS
VTS/5 D1 WHI2 METRE LENGTHSFOR (NON UK) MARKETS
NOTE each main carrierrequires two straight covers
20m
30m
VTS/2081 WHIYT1-YT3 MINI TRUNKING ADAPTOR.USE APPROPRIATE YEA ADAPTOR (YEA1-YEA3) TO CONNECT MINI TRUNKING
VTS/2084 WHIYT4 MINI TRUNKING ADAPTOR
10
10 VTS/2050 WHI50 X 50MM TRUNKING ADAPTOR
10VTS/2015 WHIEND CAP RETAINER
VTS/2016 WHIEND CAP COVER
1
1 VTS/2090 WHICROSSOVER BRIDGE
10VTS/2011 WHICABLE RETAINER
10VTS/2006 WHIEND CAP ASSEMBLY
2
VTS/2005 WHI 2 VTS/2010 WHIUSED TO JOIN 2 COVERPIECES AT REMOTE POINTFROM COUPLER
10 VTS/2004 WHIINCLUDES ADDITIONAL SCREW FIXING FOR EXTRA SECURITY50MM RADIUS BEND
1 VTS/2003 WHIINCLUDES ADDITIONAL SCREW FIXING FOR EXTRA SECURITY50MM RADIUS BEND
1
cable management | perimeter and distribution
Features
Cable Divider
MountingFrames
3 METRELENGTHS
Corner Covers
INTERNAL ANDEXTERNAL
Radius Insert
Corner Carrier
EXTERNALCORNER
INTERNAL ANDEXTERNAL
Socket Spacer
MCB/RCDHousing
Conduit/BlankAdaptor
VTS/2020 WHICONDUIT/BLANKADAPTOR WITH DRILL LOCATION.WILL ACCEPT 20/25MMCONDUIT
10
VTS/2030 WHIEXTERNAL CORNER COVER
VTS/2040 WHIINTERNAL CORNER COVER
1
1 VTS/2007 WHIINTERNAL CORNER CARRIER
VTS/2008 WHIEXTERNAL CORNER CARRIER
1
1 VTS/2009 WHI50MM RADIUS BEND INSERT FOR DATA CABLESEXTERNAL CORNER
1
VTS/25 S WHIACCESSORY SOCKET SPACERTO ESTABLISH THE MINIMUM DISTANCE BETWEEN OUTLETS
10
VTS/50 CABLE DIVIDER3 METRE LENGTHS
30m
VTS/2060 WHI2 GANG LJU6C/RJ45SUPPLIED WITH LID JOINT COVERS
VTS/2070 WHI2 GANG EURO/RJ45SUPPLIED WITH LID JOINT COVERS
10
10VTS/KMH/1 WHIVTS/MH WHIMCB/RCD HOUSINGWITH COVER
1
1
VTS/2070 WHI
VTS/2060 WHI
VTS/7000 WHI
VTS/6000 WHI
VTS/6000 WHI1 GANG ACCESSORY MOUNTING FRAME
VTS/7000 WHI2 GANG ACCESSORY MOUNTING FRAME
5
10
EMCScreening
VTS/2112OUTLET BOX ACCESSSECTION
1VTS/2111SCREENING INSERT
6m 21017SST9SPARE BONDING KIT
5
Flat Tee Flat Angle
AccessoryBoxes
VTS/6025 WHI1 GANG 25MM DEEP
VTS/6035 WHI1 GANG 35MM DEEP
VTS/2017 WHIBOX ADAPTOR
10
25
25 VTS/7025 WHI2 GANG 25MM DEEP
VTS/7035 WHI2 GANG 35MM DEEP
VTS/8028 WHI3 GANG 28MM DEEP
5
10
10
VTS/7035 WHIVTS/6035 WHI
VTS/2014 WHI50MM RADIUS BEND
1 VTS/2012 WHI50MM RADIUS BEND
1
VTS/2017 WHI
VTS/2111
VTS/8028 WHI
VTS/25 S WHI
VTS/4545 WHIFLAT ADAPTOR PLATE (NON UK)45MM X 45MM APERTURE
VTS/4545R WHIRAISED ADAPTOR PLATE (NON UK)45MM X 45MM APERTURE
VTS/35B WHIADAPTOR PLATE BASE(NON UK)
10
10
10
VTS/4545 WHI VTS/4545R WHI NCT/1G25 WHI
VTS/25 S WHIACCESSORY SOCKET SPACERTO ESTABLISH THE MINIMUM DISTANCE BETWEEN OUTLETS
K3716BOX EARTH TERMINAL
100
10
cable management | perimeter and distribution
Features
Data Trunking System
Description
The Prestige 2com trunking is a symmetrical two compartment system offering a Cat 6 flexible solutionto routing data cabling whilst maintaining the required slow bend radius of 50mm, with a separatecompartment for power cables. The trunking is normally surface mounted at dado or skirting heightbut may also be used vertically. The covers are of the snap-on type with the option of screw fixing foradded security against vandalism. Special accessories include adaptors for connection to the full rangeof MK mini trunking.
Materials
All components are manufactured from PVCu. Carriers, covers and cable dividers are extruded. Carriercouplers, corner carriers, stop ends and accessory boxes are formed by injection moulding.
Colours
The system is available in a standard white colour, with a choice of over 180 RAL paint colours onspecial orders.
Outlets
The system is designed to accommodate the complementary range of Logic Plus switches and sockets.Other MK wiring devices may also be used.
l System bend radius 50mmMeets Cat 56 data cable requirements
l Attractive styling complementary toLogic Plus
l Aesthetic one piece fitting coverswith carriers
l Two equal compartments – maximiseswiring channel capacity
l Accessory mounting in either or bothcompartments – givingflexibility/versatility
l Unobtrusive screw fixing covers tomaximise security against tampering
l Ease of installation – butt jointedconstruction, no mitring required
l Economical – cost effective 3components (2 x lids 1 base)
l Suitable for skirting or dado mounting
l Pre-drilled base – ease/speed ofinstallation
l Accommodates matching MK and otherBS switches and sockets
l Interfaces with MK Premier, and EgaIndustrial and Ega Mini Trunking andconduit Systems
l Strong PVCu sections are resistant toimpact
l Manufactured to high precisionstandards
l Full range of components, spares andaccessories
l Mounting frames for LJU6/Euro dataoutlets – cost effective, minimum spacerequirement (for mounting in SELVcompartment only).
l Choice of 180 RAL paint colours
Features
Prestige 2com Technical
Data Trunking System
Dimensions (mm)
VTS2001 main carrier+ 2 x VTS5straight covers
Weight:
2.41 Kg/m
Flat angle Flat tee
Flat angles and tees
These components arefabricated sections and spacemust be allowed for theirinclusion in runs of trunking.All other components snapon over standard trunkingprofiles.
DIMENSIONS (mm)
Flat angle A B
VTS2012 310 210
Flat T details A B C D
VTS2014 310 210 410 210
Components
Wall thickness:
VTS2001 = 2.5mm, 2.0mVTS5 = 1.7mm
60
210
1
1
A
A
B
B
C
B
D
A
PRESTIGE 2COM CABLE CAPACITY
Type of Size Cable Cmpt 1 Cmpt 1 Cmpt 1 Cmpt 1 withConductor Factor with 25mm with 35mm Ext Corner
back box back box 50mm DataBend
Full Term CSA 100% Fill (mm2)
4466 2236 1633 3132
Term at 45% Fill (mm2)
2009 1006 734 1409
Power Cables Number of Cables at 45% Fill
PVC Stranded 1.5mm2 8.6 233 116 85 163
2.5mm2 12.6 159 79 58 111
4mm2 16.6 121 60 44 84
6mm2 21.2 94 47 34 66
Data Cables Number of Cables at 45% Fill (a) and Full Capacity (b)
a b a b a b a b
Cat5E UTP 5.5mm dia. 30.2 66 147 33 74 24 54 46 103
Cat5E STP 6.0mm dia. 36.0 55 124 27 62 20 45 39 87
Cat6E UTP 6.5mm dia. 42.2 47 105 23 52 17 38 33 74
Cat6E STP 7.0mm dia. 49.0 41 91 20 45 14 33 28 63
cable management | perimeter and distribution
Prestige 2com Technical
Data Trunking System
15mm*to wall
34mm*
118mm*
34mm*
118mm*
15mm*
15mm*
190mm*
End Cap Assembly
VTS/2006
Internal CornerAssembly
VTS/2003
Coupler Assembly
VTS/2005
Flat Tee
VTS/2014
Flat Angle
VTS/2012
Component selection guide
VTS/2001
VTS/5
VTS/5
External CornerAssembly
VTS/2004
* Minimum distance
Data Trunking System
34mm
13mm
1
2
3
4
5
6
Installation guide
1. Surface to which the trunking is to be installed should be flat andprepared for decorating.
2. Establish the layout of the trunking run with particular attention tothe following: -
a. Changes in direction of the trunking.
b. The position of any feeds to or from the system.
c. The position of any connections with existing trunking/wiringsystems.
d. Allow for minimum distances between corners, couplers,screw fixings, angles and T’s (please see individual technicalsections for details).
e. When installing at skirting level, ensure room is also allowedfor future floor coverings to be fitted below trunking.
General installation guidelines
Tools and sundries required for installation:
1. Fine toothed tenon saw or a hacksaw with a 32 – 26 TPI blade forcutting the trunking, or preferably a circular saw with a 350mmdiameter fine tungsten tipped blade (100TPI approx.)
2. All purpose knife or fine file for trimming of trunking
3. Spirit level, Plumb Bob and chalk line
4. A range of screwdrivers (flat or cross point) to suit fixing screws andEarth Carrier Connectors
5. A 5.5mm Ø drill bit and No.8 Round head or Pan head screws withsuitable washers to secure the trunking.
6. Soft faced mallet to aid lid fitting
Planning the Installation
It is important to spend some time planning the installation, beforestarting. Time spent on planning the layout at this stage can avoidmistakes later on. The installation is designed for a non-conductivesubstrate, if you have any queries please contact: MK Technical SalesService Department.
cable management | perimeter and distribution
Prestige 2com Technical
Data Trunking System
118mm
100mm max
100mm max
34mm
210mm
34mm
500mm max
47mmwide
70mmwide56mm
deep
34mm
deep
7
8
9
10
General notes
Prior to installation strike a line of trunking usinga plumb and chalk line for vertical, and spiritlevels for horizontal runs.
Drill Holes in supporting walls prior to fixing
When mounting at skirting level allowanceshould be made for thickness of floor finish
Start Installation at a corner position
Profile N begin by clipping Corner Extensionsto their respective Corner Carriers
Debur all carrier cut ends
Carrier couplers must be placed at alljunctions between carriers
Leave a gap of 5mm for expansion in longruns
Fixings require washers and domed headscrews
Fixings to be at 500mm centres and also atpoints within 100mm of each end
Cut trunking to allow for mini trunking /conduit 10a and box adaptor crossoverbridge, 10b.
1
2
3
4
5
6
7
8
9
10
Data Trunking System
13mm
for joint
cove
r
Trunking Covers to be cut 8-10mm shorter than Trunking Base
Cen
tre
13
14
15
16
17
18
11
E
19
Debur all cover cut ends
Insert accessories in the following order
a Box adaptor
b Accessory Boxes
c Appropriate slide (VTS2081 shown)
d Cross over bridge
e External Corner Radius (into the Data/Telecom compartment)
Power Cables
Data / Communication cables
Mark position where mains entry is required
Installation guide continued
13
14
15
11
12
cable management | perimeter and distribution
Prestige 2com Technical
Data Trunking System
1 gang 76mm 2 gang 137mm 3 gang 197mm for outlet boxes
88mmfor minitrunkingadaptor
A
B
C
D
17
18
Drill 4.5mm dia. clearance hole to allow fixing of screw.
Figure 1
16
17
18
19
Fit covers by locating them correctly into position andpushing them firmly to snap in place
Determine whether corners need to be screw fixed (Fig 1).Continue to locate correctly the Corner and Joint covers andpush them firmly until they snap into place. Fit theappropriate badge to the Corner Covers.
Fit covers by locating them correctly into position andpushing them firmly to snap in place
Fit end caps by pushing them on from the front so the clipsslide behind the retainers and engage in the main carrier.
MK ELECTRICMK Electric (Singapore) Pte Ltd8 Pandan Crescent, UE Tech Park Telephone : (65) 6461 6333 Facsimile : (65) 6461 6336 / (65) 6461 6338#01-06 (LL4), Singapore 128464