mkelectric.co.uk 622 CABLE MANAGEMENT PERIMETER AND DISTRIBUTION Prestige 2Com Technical PRODUCT APPLICATION PRESTIGE 3D DADO CABLE MANAGEMENT Prestige 3D Dado Cable Management installed with Part M Compliant Graphite Logic Plus Socket Outlets with Outboard Rockers, alongside USB Outlets for convenient charging of mobile phones and other portable devices. This system is an ideal specification for a project with high sustainability credentials. Prestige 3D extrusions are manufactured from 100% recycled content* and the whole system is made in the UK. Logic Plus Socket Outlets are also made in the UK offering a much reduced carbon footprint when compared to some imported products. To find out more visit www.mkelectric.co.uk *Based on 2014 Consumption PRODUCT APPLICATION

Transcript of CABLE MANAEMENT Prestige 2Com - MK Electric

Page 1: CABLE MANAEMENT Prestige 2Com - MK Electric

mkelectric.co.uk

622

CA

BLE

MA

NA

GE

ME

NT

PERI

MET

ER A

ND

DIST

RIBU

TION

Prestige 2ComTechnical

PRODUCT APPLICATIONPRESTIGE 3D DADO CABLE MANAGEMENT

Prestige 3D Dado Cable Management installed with Part M Compliant Graphite Logic Plus Socket Outlets with Outboard Rockers, alongside USB Outlets for convenient charging of mobile phones and other portable devices.This system is an ideal specification for a project with high sustainability credentials. Prestige 3D extrusions are manufactured from 100% recycled content* and the whole system is made in the UK. Logic Plus Socket Outlets are also made in the UK offering a much reduced carbon footprint when compared to some imported products.

To find out more visit www.mkelectric.co.uk

*Based on 2014 Consumption

PR

OD

UC

T

AP

PL

ICA

TIO

N

Page 2: CABLE MANAEMENT Prestige 2Com - MK Electric

Technical Hotline +44 (0)1268 563720

CA

BLE

MA

NA

GE

ME

NT

PERIMETER AND

DISTRIBUTION

623

Standards and ApprovalsThe Prestige 2com trunking is a symmetrical two compartment system offering a Cat 7 flexible solution to routing data cabling whilst maintaining a slow bend radius of 50mm, with a separate compartment for power cables.

The trunking is normally surface mounted at dado or skirting height but may also be used vertically. The covers are of the snap-on type with the option of screw fixing for added security against vandalism. Special accessories include adaptors for connection to the full range of MK Ega Mini Trunking.

TECHNICAL SPECIFICATION

MATERIALSAll components are manufactured from PVCu. Carriers, covers and cable dividers are extruded. Carrier couplers, corner carriers, stop ends and accessory boxes are formed by injection moulding.

COLOURSThe system is available in a standard white colour.

OUTLETSThe system is designed to accommodate the complementary range of Logic Plus switches and sockets. Other MK wiring devices may also be used.

Classifications to BS EN 50085-1:2005 and BS EN 50085-2-1:2006 available on request.

FEATURES

l System bend radius 50mm Exceeds Cat 5e, 6 and 7 data cable requirements

l Attractive styling complementary to Logic Plus

l Aesthetic one piece fitting covers with carriers

l Two equal compartments – maximises wiring compartment capacity

l Accessory mounting in either or both compartments – giving flexibility/ versatility

l Unobtrusive screw fixing covers to maximise security against tampering

l Ease of installation – butt jointed construction, no mitring required

l Economical – cost effective 3 components (2 x lids, 1 base)

l Suitable for skirting or dado mounting

l Pre-drilled base – ease/speed of installation

l Accommodates matching MK and other BS switches and sockets

l Interfaces with MK Premier, Ega Industrial and Ega Mini Trunking and Conduit Systems

l Strong PVCu sections are resistant to impact

l Manufactured to high precision standards

l Full range of components, spares and accessories

l Mounting frames for LJU6C and Euro data outlets – cost effective, minimum space requirement (for mounting in SELV compartment only)s

l All extrusions manufactured from 100% recycled material*

For a full range of corresponding products,

see pages 311-316 in the product selector.

Prestige 2ComTechnical

* Based on 2014 consumption

DescriptionThe Prestige 2com trunking is a symmetrical two compartment system offering a Cat 7 flexible solution to routing data cabling whilst maintaining a slow bend radius of 50mm, with a separate compartment for power cables. The trunking is normally surface mounted at dado or skirting height but may also be used vertically. The covers are of the snap-on type with the option of screw fixing for added security against vandalism. Special accessories include adaptors for connection to the full range of MK Ega Mini Trunking.

Data Trunking System

Page 3: CABLE MANAEMENT Prestige 2Com - MK Electric

mkelectric.co.uk

624

CA

BLE

MA

NA

GE

ME

NT

PERI

MET

ER A

ND

DIST

RIBU

TION

CABLE CAPACITY

TYPE OF CONDUCTOR SIZE CABLE

FACTOR

COMPARTMENT 1COMPARTMENT 1

WITH 25MMBACK BOX

COMPARTMENT 1WITH 35MMBACK BOX

COMPARTMENT 1EXT CORNER

50MM DATA BEND

Full Term CSA 100% Fill (MM2)

4466 2236 1633 3132

TERM AT 45% FILL (MM2)

2009 1006 734 1409

POWER CABLES NUMBER OF CABLES AT 45% FILL

PVCstranded

1.5mm2 8.6 233 116 85 163

2.5mm2 12.6 159 79 58 111

4mm2 16.6 121 60 44 84

6mm2 21.2 94 47 34 66

DATA CABLESNUMBER OF CABLES AT 45% FILL (A) AND FULL CAPACITY (B)

A B A B A B A B

Cat 5E UTP 5.5mm dia. 30.2 66 147 33 74 24 54 46 103

Cat 5E STP 6.0mm dia. 36.0 55 124 27 62 20 45 39 87

Cat 6 UTP 6.5mm dia. 42.2 47 105 23 52 17 38 33 74

Cat 6 STP 7.0mm dia. 49.0 41 91 20 45 14 33 28 63

Cat7 8.0mm dia. 64 12 27 26 59 4 9 13 30

FLAT ANGLES DIMENSIONS (MM)

LIST NO DESCRIPTION A B C D

VTS2012WHI Flat angle 310 210

VTS2014WHI Flat T details 310 210 410 210

Prestige 2ComTechnical

FLAT ANGLE FLAT TEE

Flat Angles and TeesThese components are fabricated sections and space must be allowed for their inclusion in runs of trunking. All other components snap on over standard trunking profiles.

COMPONENTS

VTS2001WHI main carrier + 2 x VTS5WHI straight covers

WEIGHT:

2.41 Kg/m

WALL THICKNESS:

VTS2001WHI = 2.5mm, 2.0m VTS5WHI = 1.7mm

60

210

1

1

A

A

B

B

C

B

D

A

Data Trunking System

Dimensions (mm)

Page 4: CABLE MANAEMENT Prestige 2Com - MK Electric

Technical Hotline +44 (0)1268 563720

625

CA

BLE

MA

NA

GE

ME

NT

PERIMETER AND

DISTRIBUTIONPrestige 2Com

Technical

15mm*to wall

34mm*

118mm*

34mm*

118mm*

15mm*

15mm*

190mm*

* Minimum distance

Data Trunking System

Component Selection Guide

VTS2001WHI

VTS5WHI

VTS5WHI

END CAP ASSEMBLYVTS2006WHI

EXTERNAL CORNER ASSEMBLYVTS2004WHI

EXTERNAL CORNER FIXING SCREW AND COVERVTS2019WHI

INTERNAL CORNER ASSEMBLYVTS2003WHI

INTERNAL CORNER FIXING SCREW AND COVER (SPARE)VTS2018WHI

COUPLER ASSEMBLYVTS2005WHI

FLAT TEEVTS2014WHI

FLAT ANGLEVTS2012WHI

Page 5: CABLE MANAEMENT Prestige 2Com - MK Electric

mkelectric.co.uk

626

CA

BLE

MA

NA

GE

ME

NT

PERI

MET

ER A

ND

DIST

RIBU

TION Prestige 2Com

Technical

34mm

13mm

118mm

100mm max

100mm max

34mm

210mm

34mm

500mm max

47mmwide

70mmwide56mm

deep

34mm

deep

1

2

3

5

Planning the InstallationIt is important to spend some time planning the installation, before starting. Time spent on planning the layout at this stage can avoid mistakes later on. The installation is designed for a non-conductive substrate, if you have any queries please contact: MK Technical Sales Service Department. Telephone 01268 563720.

1. Surface to which the trunking is to be installed should be flat and prepared for decorating.

2. Establish the layout of the trunking run with particular attention to the following: -

a. Changes in direction of the trunking.

b. The position of any feeds to or from the system.

c. The position of any connections with existing trunking/wiring systems.

d. Allow for minimum distances between corners, couplers, screw fixings, angles and tees (please see individual technical sections for details).

e. When installing at skirting level, ensure room is also allowed for future floor coverings to be fitted below trunking.

GENERAL INSTALLATION GUIDELINES

TOOLS AND SUNDRIES REQUIRED FOR INSTALLATION:

1. Fine toothed tenon saw or a hacksaw with a 32 – 26 TPI blade for cutting the trunking, or preferably a circular saw with a 350mm diameter fine tungsten tipped blade (100T approx.)

2. All purpose knife or fine file for trimming of trunking

3. Spirit level, Plumb Bob and chalk line

4. A range of screwdrivers (flat or cross point) to suit fixing screws and Earth Carrier Connectors

5. A 5.5mm Ø drill bit and No.8 Round head or Pan head screws with suitable washers to secure the trunking.

6. Soft faced mallet to aid lid fitting

4

Data Trunking System

Installation Guide

Page 6: CABLE MANAEMENT Prestige 2Com - MK Electric

Technical Hotline +44 (0)1268 563720

627

CA

BLE

MA

NA

GE

ME

NT

PERIMETER AND

DISTRIBUTIONPrestige 2Com

Technical

34mm

13mm

118mm

100mm max

100mm max

34mm

210mm

34mm

500mm max

47mmwide

70mmwide56mm

deep

34mm

deep

6

7

8

9a

General NotesPrior to installation strike a line of trunking using a plumb and chalk line for vertical, and spirit levels for horizontal runs.

Drill Holes in supporting walls prior to fixing

When mounting at skirting level allowance should be made for thickness of floor finish

Start Installation at a corner position

Debur all carrier cut ends

Carrier couplers must be placed at all junctions between carriers

Leave a gap of 5mm for expansion in long runs

Fixings require washers and No. 8 Round or Pan head screws

Fixings to be at 500mm centres and also at points within 100mm of each end

Cut trunking to allow for mini trunking / conduit (9a) and box adaptor crossover bridge (9b).

1

2

3

4

5

6

7

8

9

9b

Data Trunking System

Page 7: CABLE MANAEMENT Prestige 2Com - MK Electric

mkelectric.co.uk

628

CA

BLE

MA

NA

GE

ME

NT

PERI

MET

ER A

ND

DIST

RIBU

TION Prestige 2Com

Technical

13mm

for jo

int

cove

r

1 gang 76mm2 gang 137mm3 gang 197mmfor outlet boxes

88mmfor mini trunking adaptor

Trunking Covers to be cut 8-10mm shorter than Trunking Base

Cen

tre

12

13

14

15

16

17

10

e

18

Debur all cover cut ends

Insert accessories in the following order

a Box adaptor

b Accessory Boxes

c Appropriate slide (VTS2081 shown)

d Cross over bridge

e External Corner Radius (into the Data/Telecom compartment)

Power Cables

Data / Communication cables

Mark position where mains entry is required

Installation Guide Continued

12

13

14

10

11

Data Trunking System

Page 8: CABLE MANAEMENT Prestige 2Com - MK Electric

Technical Hotline +44 (0)1268 563720

629

CA

BLE

MA

NA

GE

ME

NT

PERIMETER AND

DISTRIBUTIONPrestige 2Com

Technical

13mm

for jo

int

cove

r

1 gang 76mm2 gang 137mm3 gang 197mmfor outlet boxes

88mmfor mini trunking adaptor

Trunking Covers to be cut 8-10mm shorter than Trunking Base

Cen

tre

Fit covers by locating them correctly into position and pushing them firmly to snap in

place.

Determine whether corners need to be screw fixed (Fig 1). Continue to locate correctly the

Corner and Joint covers and push them firmly until they snap into place. Fit the appropriate badge to the Corner Covers.

Fit covers by locating them correctly into position and pushing them firmly to snap in

place.

Fit end caps by pushing them on from the front so the clips slide behind the retainers

and engage in the main carrier.

a

b

c

d

16

17

FIGURE 1

15

16

17

18

Data Trunking System

Drill 4.5mm dia.clearance holeto allow fixing of screw.