Presentasi Camag DKI

download Presentasi Camag DKI

of 46

Transcript of Presentasi Camag DKI

  • 8/4/2019 Presentasi Camag DKI

    1/46

    Planar Chromatography

  • 8/4/2019 Presentasi Camag DKI

    2/46

    What you need:

    a method TLC or HPTLC precoated

    layers

    suitable equipment

    know how

    Planar Chromatography...

  • 8/4/2019 Presentasi Camag DKI

    3/46

    A method...

    Developed andvalidated byCAMAG

    Planar Chromatography...

  • 8/4/2019 Presentasi Camag DKI

    4/46

    CAMAG Laboratory

  • 8/4/2019 Presentasi Camag DKI

    5/46

    www.camag.com

  • 8/4/2019 Presentasi Camag DKI

    6/46

    Download methods for free...

    www.camag-laboratory.com

  • 8/4/2019 Presentasi Camag DKI

    7/46

    What you need :

    a method

    TLC or HPTLC precoated

    layers suitable equipment

    know how

    Planar Chromatography...

  • 8/4/2019 Presentasi Camag DKI

    8/46

    TLC/HPTLC precoated layers

    available at CAMAG or atyour lab supplier

    Planar Chromatography...

  • 8/4/2019 Presentasi Camag DKI

    9/46

    TLC vs. HPTLC TLC HPTLC

    Mean particle size: 10 - 15 m 5 - 7 m

    Particle distribution: wide narrow

    Layer thickness: 250 m 100, 200 m

    Number of samples: max. 12 36 - 72

    Migration distance: 100 - 150 mm 30 - 70 mm

    Migration time: 30 - 200 min 3 - 20 minSolvent use: 50 ml 5 - 10 ml

    Detection limit: Abs 100 - 1000 ng 10 - 100 ng

    Fluor 1 - 100 ng 0,1 - 10 ng

  • 8/4/2019 Presentasi Camag DKI

    10/46

    Comparison TLC-HPTLC

    Flavonoids (Ph.Eur.4)

    HPTLC plate 20 x 10 cm7 cm migration

    10 mL solvent

    10 min.

    TLC plate 20 x 20 cm

    12 cm migration

    25 mL solvent

    32 min.

  • 8/4/2019 Presentasi Camag DKI

    11/46

    What you need:

    a method

    TLC or HPTLC precoated

    layers suitable equipment

    know how

    Planar Chromatography...

  • 8/4/2019 Presentasi Camag DKI

    12/46

    Planar Chromatography

    Sample application

    Chromatogram development

    Detection & quantitative evaluation

    Documentation

    Post-Chrom. Derivatization

  • 8/4/2019 Presentasi Camag DKI

    13/46

    Planar Chromatography

    Sample application is the mostcritical step inthe TLC procedure.

    Errors which occur during sample application,cannot be compensated for in chromatogramdevelopment or evaluation.

    Sample application

  • 8/4/2019 Presentasi Camag DKI

    14/46

    step by step

    Sample Application

    Planar Chromatography...

  • 8/4/2019 Presentasi Camag DKI

    15/46

    Sample Application

    Nanomat

    volume volume volume

    1L

    Linomat

    Spray-on technique

    2L 1L 2L 10L5L

    Spot versus Band application

  • 8/4/2019 Presentasi Camag DKI

    16/46

    Sample application - semi automatic

    LINOMAT5

    Sprays on samples as narrow bands

    Larger volumes can be applied (1 - 200 L)

    Precise sampling of programmed volumes Sample application for:

    qualitative

    quantitative

    preparative separation

    LINOMAT

  • 8/4/2019 Presentasi Camag DKI

    17/46

    Linomat 5

    Keypad & Display

    Plate holderTurret with dosing syringe

  • 8/4/2019 Presentasi Camag DKI

    18/46

    Sample application: fully automatic ATS4

    PC - controlled

    Application of spots, bands or rectangles

    Reduced time for application

    Improved reproducibility

    GLP compliant

    Suitable for danger substances

  • 8/4/2019 Presentasi Camag DKI

    19/46

    Automatic TLC Sampler 4

    DisplayRack for sample vialsor micro-titer plates

    Turret with dosing syringe

    Protection cover Waste bottleRinsing bottle

    Plate holder

  • 8/4/2019 Presentasi Camag DKI

    20/46

    Automatic TLC Sampler 4

    Contact transfer = Spots

    Spray-on = Bands

    Spray-on = rectangular

  • 8/4/2019 Presentasi Camag DKI

    21/46

    step by step

    Sample Application Chromatogram Development

    Evaluation

    Documentation

    Planar Chromatography...

  • 8/4/2019 Presentasi Camag DKI

    22/46

    Chromatogram development

    Fully automatic gradient separation via AMD2

    Manual separation via Glass tank

    Automatic isocratic separation via ADC

  • 8/4/2019 Presentasi Camag DKI

    23/46

    ADC2

    Chromatogram developmentwith standardized conditions

    in a conventional glass tank fully automatic

    saturation controlled

    humidity controlled

    unsurpassed reproducible

    qualifiable IQ/OQ

  • 8/4/2019 Presentasi Camag DKI

    24/46

    TLC -sprayer

  • 8/4/2019 Presentasi Camag DKI

    25/46

    step by step

    Sample Application Chromatogram Development

    Evaluation

    Documentation

    Planar Chromatography...

  • 8/4/2019 Presentasi Camag DKI

    26/46

    Visual inspection in Viewing box

  • 8/4/2019 Presentasi Camag DKI

    27/46

    Densitometry

    TLC Scanner 3

  • 8/4/2019 Presentasi Camag DKI

    28/46

    Scanning the chromatogram

    Integrated track

  • 8/4/2019 Presentasi Camag DKI

    29/46

    Densitometry

  • 8/4/2019 Presentasi Camag DKI

    30/46

    Spectrum Scan

    Display of the selected spectra

  • 8/4/2019 Presentasi Camag DKI

    31/46

    Spectrum LibraryAnalysis spectrum compared

    with a spectrum from the library

  • 8/4/2019 Presentasi Camag DKI

    32/46

    Detection multi wavelength scan

    A selection of up to

    31 WL is possible

  • 8/4/2019 Presentasi Camag DKI

    33/46

    Classical densitometry Multi Wavelength Scan

    One track at all wavelengths

  • 8/4/2019 Presentasi Camag DKI

    34/46

    step by step

    Sample Application Chromatogram Development

    Evaluation

    Documentation

    Planar Chromatography...

  • 8/4/2019 Presentasi Camag DKI

    35/46

    TLC VISUALIZER:

    Documentation, Evaluation, Archiving

  • 8/4/2019 Presentasi Camag DKI

    36/46

    TLC Visualizer Design has been enhanced to further improve the

    homogeneity of the illumination of the plate:

    254 nm, short wave UV - Reflectance

    366 nm, long wave UV - Reflectance

    White light - Reflectance and/orTransmission.

    Ergonomic design: Easy access in to the illuminationcompartment via large sliding door.

    separate viewing window with UV-protection

    Timer for automatic switch-off of the light sources

  • 8/4/2019 Presentasi Camag DKI

    37/46

    Documentation system TLC VISUALIZER

  • 8/4/2019 Presentasi Camag DKI

    38/46

    Manual Optimization

    If desired, a region of interest can be defined, in which the brightestspot is automatically found.

  • 8/4/2019 Presentasi Camag DKI

    39/46

    RF-Tool to measure RF of the substances

    winCATS with TLC Visualizer

  • 8/4/2019 Presentasi Camag DKI

    40/46

    is GLP/GMP compliant:

    All significant parameters of

    a TLC method are recordedand electronically stored.

    Planar Chromatography...

  • 8/4/2019 Presentasi Camag DKI

    41/46

    What you need:

    a method TLC or HPTLC precoated

    layers suitable equipment

    know how

    Planar Chromatography...

  • 8/4/2019 Presentasi Camag DKI

    42/46

    Know How...

    Application LabTraining courses

    individual Training

    Planar Chromatography...

  • 8/4/2019 Presentasi Camag DKI

    43/46

    Why CAMAG?

    > 40 years of experience

    satisfied customers

    individual solutions

    competent After Sales Service

    training courses

    Planar Chromatography...

  • 8/4/2019 Presentasi Camag DKI

    44/46

    CAMAG worldwide CAMAG Muttenz / Switzerland

    www.camag.ch

    CAMAG China Supporting Unit Hong Kong & Guangzhouwww.camag-china.com

    CAMAG Berlin / Germanywww.camag-berlin.de

    CAMAG Scientific Inc. North Carolina / USA

    www.camagusa.com

    CAMAG Regional Support Unit Bombay / India

    www.hptlc-anchrom.in

  • 8/4/2019 Presentasi Camag DKI

    45/46

    ..... no laboratory is

    complete without amodern HPTLC system!

    Conclusion ...

  • 8/4/2019 Presentasi Camag DKI

    46/46

    Thanks for your attention !