PowerFlex 700S Drives with Phase II Control (4.002)

12
Release Notes PowerFlex ® 700S Drives with Phase II Control (4.002) These release notes correspond to major revision (4), minor revision (2) of firmware for PowerFlex ® 700S drives with Phase II control. Introduction The following information is included in this document: Determining Firmware Revision Level To determine the firmware version for a PowerFlex 700S drive, view parameters 314 [VPL Firmware Rev] and 315 [VPL Build Number]. The firmware version is the combination of the data in these parameters. For information about: See page: Determining Firmware Revision Level 1 Firmware Upgrades 2 Enhancements 2 Corrected Anomalies 5 Known Anomalies 6 Restrictions 8 Rockwell Automation Support 11 Installation Assistance 11 New Product Satisfaction Return 11 Example: Firmware Version 4.002.01 Firmware revision from parameter 314 [VPL Firmware Rev] Firmware build number from parameter 315 [VPL Build Number]

Transcript of PowerFlex 700S Drives with Phase II Control (4.002)

untitledPowerFlex® 700S Drives with Phase II Control (4.002)
These release notes correspond to major revision (4), minor revision (2) of firmware for PowerFlex® 700S drives with Phase II control.
Introduction The following information is included in this document:
Determining Firmware Revision Level
To determine the firmware version for a PowerFlex 700S drive, view parameters 314 [VPL Firmware Rev] and 315 [VPL Build Number]. The firmware version is the combination of the data in these parameters.
For information about: See page: Determining Firmware Revision Level 1 Firmware Upgrades 2 Enhancements 2 Corrected Anomalies 5 Known Anomalies 6 Restrictions 8 Rockwell Automation Support 11 Installation Assistance 11 New Product Satisfaction Return 11
Example: Firmware Version 4.002.01
Firmware build number from parameter 315 [VPL Build Number]
2 PowerFlex® 700S Drives with Phase II Control (4.002)
Firmware Upgrades This section describes procedures for upgrading your firmware:
When updating firmware version 1.xx to version 2.xx or higher, boot code v1.06 must be flashed into the drive. Use the following procedure to upgrade the boot code along with the application code:
Upgrading from version 1.12 (or before 2.xx release)
1. Flash 700S2bt01_06.bin using 1203-SSS Series B and HyperTerminal.
2. Cycle the power (automatically).
3. HIM displays "No System Application..." error message - ignore this error.
4. Flash 700S2ap04_002.bin using 1203-SSS Series B and HyperTerminal.
5. Cycle the power (automatically).
6. HIM displays as normal.
If upgrading firmware version after version 2.xx (i.e., v2.03), upgrading the application firmware only is required.
Enhancements This section describes the enhancements included in this revision:
Added PCCC N-File Function to Software Control Bar
This function has been added to allow drive control via the Control Bar from DriveExecutive and the ability to use the available DriveTools SP Wizards when controlling a PowerFlex 700S Phase II drive with DriveLogix using all DriveLogix communications options.
Added Full DPI Configuration Support
This new configuration allows a drive to support all Automatic Device Configuration (previously, Automatic Device Replacement) requirements.
Added Support for Frame 14 Drive
This firmware revision supports the new frame 14 rating; 690 volts AC input, 1500 amps.
PowerFlex® 700S Drives with Phase II Control (4.002) 3
Added New “RideThru” Alarm (F92)
This feature provides a “RideThru” (F92) alarm when the drive is in a Ride Through condition and parameter 406 [Power Loss Mode] is set to 0 “Coast” or 5 “Flux Only”. When in a RideThru alarm state the HIM displays the alarm icon (bell), the alarm queue displays F92 and bit 27 “Reserved” of parameter 328 [Alarm Status 3] is set.
Bits 8, 9 and 21 of Parameter 513 [V/Hz Mode Config] now “Run Read Only”
The firmware has been updated to inhibit changing bits 8 “BusGain Comp”, 9 “ReflWaveComp” and 21 “VltMinorLpEn” while the drive is in run mode.
Prevent Automatic Tach Switch in Permanent Magnet Mode
With this firmware revision, bit16 “Auto Tach Sw” of parameter 153 [Control Options] cannot be set when the drive is in the Permanent Magnet mode (Par 485 [Motor Ctrl Mode] = 2 “PMag Motor”), thus, not allowing a switch to another feedback device (i.e. another encoder or sensorless feedback).
Improved the “Fast Flux Up” Function and Flux Current (Id) Reference
This enhancement improved the fast flux up performance and the transition from a fast flux up reference to rated flux reference.
Motor Control Test Point Parameters now Updated in Task 1
With this enhancement the Motor Control test point parameters (466, 467, 468, 473, 474, 475 and 476) are now updated in Task 1 (the fastest VPL interrupt routine), providing more meaningful data.
Enhanced Slip Tuning for High Inertia Motors
The “Slip Tune” function was enhanced to improve slip tuning for high inertia motors.
Changed the Turn-Off Point for the Analog Output Scale Parameters
The turn-off point (minimum value) of the Analog Output Scale parameters (835 and 842) has been changed from +/-0.001 to +/-0.0001. This change allows you to monitor a smaller analog output value.
4 PowerFlex® 700S Drives with Phase II Control (4.002)
Enhanced Processor Utilization
The Processor utilization was improved in order to provide more time for FOC/Encoder modes for frames 1 - 6. Note: This change had previously been implemented for the high horse power drives (frame 9 and up).
Minimum Value of Parameter 415 [BusReg/Brake Ref] Changed to 100.0 for 600V Drives
The minimum value of parameter 415 [BusReg/Brake Ref] has been changed from 110.5 to 100.0 when 600V is selected on a 600V/690V AC input, frame 5 and above drive. This change provides the ability to adjust the dynamic brake turn on voltage level in order to prevent bus over voltages for shared bus applications when 690V, frames 5 and above drives, are used in combination with frame 4 and lower drives.
Miscellaneous Database Changes
The following database changes were made for this firmware revision:
• The maximum value of parameter 2 [Motor NP FLA] has been changed from 2000 to 3000 amps to accommodate frame 14 drives. Note: This value is calculated by the drive.
• The maximum value of parameter 7 [Motor Poles] has been changed from 60 to 128. This change allows the drive to use higher pole count motors.
• Parameters 48 [Spd Ref Bypass2] and 916 [SL Clr Events] are now “recallable”. This change now saves the link for these parameters.
• Added the following Fault Test Point selections to parameter 329 [Fault TP Sel]:
– 24 “ElpsSec.mSec”, Elapsed time in seconds and milliseconds since the last power up
– 25 “ElpsMin.Sec”, Elapsed time in minutes and seconds since the last power up
– 26 “ElpsHour.Min”, Elapsed time in hours and minutes since the last power up
– 27 “ElpsDay.Hour”, Elapsed time in days and hours since the last power up
• The default value for parameter 370 [HiHp InPhsLs Cfg] was changed from 3 “Flt RampStop” to 2 “FltCoastStop”.
• The maximum value of parameter 400 [Rated Amps] has been changed from 2500 to 3000 amps to accommodate frame 14 drives.
PowerFlex® 700S Drives with Phase II Control (4.002) 5
• Added Motor Control test point selection 163 “Flux Up Time” to parameters 466 [MC TP1 Select] and 473 [MC TP2 Select]. The Motor Control test point allows you to see the flux up time for both Fast Flux Up and standard flux conditions.
Corrected Anomalies This section describes the anomalies corrected in this revision:
“HiHp Drv OvrLoad” Fault (F71) Occurs when Saving to EEPROM while Drive is Running
The high horse power drives would experience a “HiHP Drv OvrLoad” (F71) fault when manually invoking the EEPROM function while the drive is running. This firmware revision corrects this anomaly.
Improved Thermal Regulator Behavior for PowerFlex 700L Drives
The behavior of the thermal regulator has been improved to support PowerFlex 700L drives.
Incorrect Torque Reference Calculation in Permanent Magnet Mode
The torque reference calculation for Permanent Magnet Motor control mode has been corrected in this firmware revision to provide a more accurate torque current.
“Inv Otemp Trip” (F15) Occurs During 600/690V AC Frame 12 Drive Power Up
This firmware revision provides a different power up time for the 600/690V AC frame 12 drive to correct an erroneous “Inv Otemp Trip” fault (F15).
Motion Homing Position Error in Rotary Mode and Registration Problem
This firmware corrects an anomaly that caused the drive to look for the “Armed” bit when it should be looking for the “Found” bit (Lgx73742).
Over Junction Temperature at 2 kHz Carrier Frequency with PowerFlex 700L Drive
The junction temperature calculation for the PF700L did not correctly compensate for a change in carrier frequency from 4 KHz to 2 KHz. This anomaly has been corrected with this firmware revision.
6 PowerFlex® 700S Drives with Phase II Control (4.002)
Ramp to Stop, Current Limit Stop and Coast to Stop Fault Response Not Functioning
This anomaly prevented faults that could be configured as 2 “FltCoastStop”, 3 “Flt RampStop” or 4 “FltCurLimStp” from responding with the corresponding action (i.e., coast to stop, ramp to stop or current limit stop) when the corresponding fault occurred. This anomaly has been corrected in this firmware revision. The default value for parameter 370 was changed from 3 “Flt RampStop” to 2 “FltCoastStop” in order to maintain the functionality that was present in earlier firmware releases.
Skip Band Anomalies with Zero and Negative Set Points in V/Hz Mode
This anomaly caused the drive to ignore the minimum value when a zero value was set between the maximum and minimum skip frequency values when the drive is running in V/Hz mode. The firmware has been corrected to recognize a zero value set between the maximum and minimum skip frequency values.
Save HIM Password into EEPROM after Power Down
The anomaly where the HIM password was deleted when power was cycled to the drive has been corrected in this firmware version. When utilized, the HIM password will now be saved into EEPROM when the drive is powered down.
Known Anomalies This firmware revision contains the following known anomalies:
DriveTools SP Alarm Message when Connecting to PowerFlex 700S Phase II Drive with DriveLogix
The following alarm message displays in DriveTools SP v4.002 and earlier when connecting to a PowerFlex 700S Phase II drive with DriveLogix via the Ethernet:
"The peripheral device port number (0) is invalid. Valid port number range from 1 to 7."
This anomaly can be prevented by completing the following:
1. From the Drive menu, select Create Database.
2. When the database has been created, shut down DriveTools SP.
3. Restart DriveTools SP and reconnect to the drive.
PowerFlex® 700S Drives with Phase II Control (4.002) 7
Instantaneous Overcurrent Fault (F27) May Occur when Saving to EEPROM on High Horsepower Drives
An instantaneous over current fault (“Inst Overcurrent” - F27) may occur when saving to EEPROM from the HIM or DriveExecutive while the drive is running on high horsepower drives (frames 9 - 14). Note: The drive automatically saves all parameter values to EEPROM.
“MC Firmware” Fault (F30) Occurs when Downloading Parameters from HIM after Flash Upgrade to Firmware v3.001 and Higher
At drive start up, an “MC Firmware” (F30) fault will occur for drive frame sizes 9-13 if the following conditions are met:
• You have flash upgraded to firmware v3.001 or higher, • You have downloaded parameters to the drive from an earlier firmware
version via the HIM, and • Parameter 551 [CurrFdbk AdjTime] is set to a value less than 5
In this case, parameter 551 must be set to the correct value. The correct values are:
• Frame 9, set P551 to 5 • Frame 10, set P551 to 33 • Frame 11, set P551 to 34 • Frame 12, set P551 to 33 • Frame 13, set P551 to 40 • Frames 1-6, P551 should be set to 0
With firmware version 3.001 or higher, the drive will automatically set the correct value for the drive. This is completed at power up, provided the value was not changed manually.
Parameter 414 [Brake/Bus Cnfg] Incorrectly Set after Start Up Wizard Completes
When the PowerFlex 700S Phase II Start Up Wizard is run, the drive correctly sets bit 2 “Bus Ref High” and 3 “Bus Reg En” of parameter 414 [Brake/Bus Cnfg], but does not set this parameter back to the previous settings (if different) when the wizard is complete.
Parameter 554 [LED Status] Not Functioning Properly
Parameter 554 [LED Status], bit 15 “DL ComActive”, does not work.
8 PowerFlex® 700S Drives with Phase II Control (4.002)
SynchLink Does Not Reset Properly when “SL Reset” Bit is Set
Setting bit 3 “SL Reset” of parameter 904 [SL Node Cnfg] in PowerFlex 700S Phase II drives does not appear to reset SynchLink properly for DriveLogix Motion control. A power cycle is required to reset SynchLink so that the CST master is set and DriveLogix Motion control works or to reset the Timekeeper.
Trend Functions May Cause Drive to Stop Running
When using the trend functions, a PowerFlex 700S drive may stop running. The power to the drive must be cycled in order to correct this condition. If the DriveLogix option is present the 5730 controller may lose its program.
Restrictions The following restrictions apply to this revision of firmware:
Clearing the “Find Home” Bit in Parameter 741 [Position Status]
If bit 24 “Find Home” in parameter 740 [Position Control] is set, bit 15 “Homed” in parameter 741 [Position Status] remains set until a start command is issued.
Current Draw Down with Multi-Motor Drive Operation
When using a PowerFlex 700S drive to run multiple motors, the drive must be sized in order to provide the total current required to run the connected motors plus the current required to line start any disconnected motors. If the drive’s total current rating is not capable of providing the total current described above, the motor speed may slow, possibly to zero, and re-accelerate the motors back to the set speed when line starting a disconnected motor.
DC Bus Overvoltage Fault (Fault 24) for High Horsepower Drives
A DC Bus overvoltage fault may occur for high horsepower drives when executing a flying start within 2 seconds of a commanded stop with no or light loads.
Homing to a Switch and Then to a Marker Not Functional with DriveLogix
When using the Homing function with a PowerFlex 700S Phase II drive with DriveLogix, you can either Home to a Switch or Home to a Marker. However, you cannot Home to a Switch and a Marker in the same command.
PowerFlex® 700S Drives with Phase II Control (4.002) 9
Motion Registration Input Limited to Digital Input 1 or Registration Input 0
The Registration input to the drive is limited to Digital Input 1 and Registration Input 0. Therefore, the RSLogix MAR (Motion Arm Registration) instruction will not function properly if Registration Input 1 is used.
Operating Mode Configuration Parameters Should Not be Changed
The following parameters should not be changed by a user:
• 510 [FVC Mode Config]
• 511 [FVC2 Mode Config]
• 512 [PMag Mode Config]
• 513 [V/Hz Mode Config]
Position Control Bits Not Available for Controller
The following bits were added to parameters 740 [Position Control] and 741 [Position Status] as part of the Position Control Static Assembly for firmware version 3.01.
• [Position Control]
– bit 14 "Homing"
– bit 15 "Homed"
However, these bits were not added to the Controller side of the Static Assembly. Therefore, the controller cannot connect to these bits when using the Position Control Communication Format via the static assembly. If it is necessary to have a controller connect to these bits, the User Defined or Custom User Defined Communication format or explicit messaging must be used.
10 PowerFlex® 700S Drives with Phase II Control (4.002)
Speed Limited Adjustable Torque (SLAT) Bits Not Available for Controller
Bits 7 "SLAT Minimum" and 8 "SLAT Maximum" were added to parameter 110 [Speed/TorqueMode] as part of the Speed Control Static Assembly for firmware version 3.01. However, these bits were not added to the Controller side of the Static Assembly. Therefore, the controller cannot connect to bits 7 and 8 when using the Speed Control Communication Format. If it is necessary to have a controller connect to these bits, the User Defined or Custom User Defined Communication format or explicit messaging must be used.
PowerFlex® 700S Drives with Phase II Control (4.002) 11
Rockwell Automation Support
Rockwell Automation provides technical information on the web to assist you in using our products. At http://support.rockwellautomation.com, you can find technical manuals, a knowledge base of FAQs, technical and application notes, sample code and links to software service packs, and a “MySupport” feature that you can customize to make the best use of these tools.
For an additional level of technical phone support for installation, configuration and troubleshooting, we offer TechConnect Support programs. For more information, contact your local distributor or Rockwell Automation representative, or visit http://support.rockwellautomation.com.
Installation Assistance If you experience a problem with a hardware module within the first 24 hours of installation, please review the information that's contained in this document. You can also contact a special Customer Support number for initial help in getting your module up and running:
New Product Satisfaction Return
Rockwell tests all of our products to ensure that they are fully operational when shipped from the manufacturing facility. However, if your product is not functioning and needs to be returned:
United States 1.440.646.3223 Monday – Friday, 8am – 5pm EST
Outside United States Please contact your local Rockwell Automation representative for any technical support issues.
United States Contact your distributor. You must provide a Customer Support case number (see phone number above to obtain one) to your distributor in order to complete the return process.
Outside United States Please contact your local Rockwell Automation representative for return procedure.
Publication 20D-RN036A-EN-P – December 2007 Copyright © 2007 Rockwell Automation, Inc. All rights reserved. Printed in USA.
www.rockwellautomation.com
Americas: Rockwell Automation, 1201 South Second Street, Milwaukee, WI 53204 USA, Tel: (1) 414.382.2000, Fax: (1) 414.382.4444
Europe/Middle East/Africa: Rockwell Automation, Vorstlaan/Boulevard du Souverain 36, 1170 Brussels, Belgium, Tel: (32) 2 663 0600, Fax: (32) 2 663 0640
Asia Pacific: Rockwell Automation, Level 14, Core F, Cyberport 3, 100 Cyberport Road, Hong Kong, Tel: (852) 2887 4788, Fax: (852) 2508 1846
Power, Control and Information Solutions Headquarters
Front Cover
Added Full DPI Configuration Support
Added Support for Frame 14 Drive
Added New “RideThru” Alarm (F92)
Bits 8, 9 and 21 of Parameter 513 [V/Hz Mode Config] now “Run Read Only”
Prevent Automatic Tach Switch in Permanent Magnet Mode
Improved the “Fast Flux Up” Function and Flux Current (Id) Reference
Motor Control Test Point Parameters now Updated in Task 1
Enhanced Slip Tuning for High Inertia Motors
Changed the Turn-Off Point for the Analog Output Scale Parameters
Enhanced Processor Utilization
Minimum Value of Parameter 415 [BusReg/Brake Ref] Changed to 100.0 for 600V Drives
Miscellaneous Database Changes
Corrected Anomalies
“HiHp Drv OvrLoad” Fault (F71) Occurs when Saving to EEPROM while Drive is Running
Improved Thermal Regulator Behavior for PowerFlex 700L Drives
Incorrect Torque Reference Calculation in Permanent Magnet Mode
“Inv Otemp Trip” (F15) Occurs During 600/690V AC Frame 12 Drive Power Up
Motion Homing Position Error in Rotary Mode and Registration Problem
Over Junction Temperature at 2 kHz Carrier Frequency with PowerFlex 700L Drive
Ramp to Stop, Current Limit Stop and Coast to Stop Fault Response Not Functioning
Skip Band Anomalies with Zero and Negative Set Points in V/Hz Mode
Save HIM Password into EEPROM after Power Down
Known Anomalies
DriveTools SP Alarm Message when Connecting to PowerFlex 700S Phase II Drive with DriveLogix
Instantaneous Overcurrent Fault (F27) May Occur when Saving to EEPROM on High Horsepower Drives
“MC Firmware” Fault (F30) Occurs when Downloading Parameters from HIM after Flash Upgrade to Firmware v3.001 and Higher
Parameter 414 [Brake/Bus Cnfg] Incorrectly Set after Start Up Wizard Completes
Parameter 554 [LED Status] Not Functioning Properly
SynchLink Does Not Reset Properly when “SL Reset” Bit is Set
Trend Functions May Cause Drive to Stop Running
Restrictions
Clearing the “Find Home” Bit in Parameter 741 [Position Status]
Current Draw Down with Multi-Motor Drive Operation
DC Bus Overvoltage Fault (Fault 24) for High Horsepower Drives
Homing to a Switch and Then to a Marker Not Functional with DriveLogix
Motion Registration Input Limited to Digital Input 1 or Registration Input 0
Operating Mode Configuration Parameters Should Not be Changed
Position Control Bits Not Available for Controller
Speed Limited Adjustable Torque (SLAT) Bits Not Available for Controller
Rockwell Automation Support
Intro
Details of the Rockwell Automation Print Specifications sheet
This print specifications sheet is designed with multiple purposes. - It is a vehicle to get the most accurate print specifications to RA-approved print vendors. - It provides authors with an explanation of all necessary fields to complete before attaching the sheet to your PDF. - It provides separate tabs so that an author can fill in all fields related to the publication on the Generic tab or publication-specific template-type tabs to minimize the number of fields an author must complete. To facilitate the most efficient use of this sheet, we recommend that you click on the publication-specific tab that most closely fits you publication and use that to complete the print specifications. IMPORTANT: Because this sheet was constructed using a sheet that RR Donnelley (RRD) uses to load print specifications, there are some columns hidden. For example, the first field you must complete is Column E, or Publication Number. Columns A to D are used for RRD purposes and with information only representatives of that RA-approved printer can complete. DO NOT delete any hidden columns from the tab you choose to use.
Definitions of Each Tab in Sheet
Generic pub print specs
Single sheet with all required columns for necessary specifications. None of the columns are completed. All must be completed before attaching the sheet to your PDF. This tab has 44 blank fields you must complete via free text type or pull-down menus.
IN, RN pub type specs
Templates with many fields already completed according to typical default settings. We intend you use this tab with publications similar to installation instructions (IN) and release notes (RN). However, you can use this sheet for other publications that are similar to INs and RNs. This sheet has 31 fields already completed and, if your publication uses the default values already completed, you must complete the additional 13 fields.
UM, RM, PM pub type specs
Templates with many fields already completed according to typical default settings. Use this tab with publications similar to user manuals (UM), reference manuals (RM) and programming manuals (PM). However, you can use this sheet for other publications that are similar to UMs, RMs and PMs. This sheet has 34 fields already completed and, if your publication uses the default values already completed, you must complete the additional 10 fields.
AP, PP pub type specs
Templates with many fields already completed according to typical default settings. Use this tab with publications similar to application solutions (AP) and product profiles (PP). However, you can use this sheet for other publications that are similar to APs and PPs. This sheet has 29 fields already completed and, if your publication uses the default values already completed, you must complete the additional 15 fields.
BR pub type specs
Templates with many fields already completed according to typical default settings. Use this tab with publications similar to brochures (BR). However, you can use this sheet for other publications that are similar to BRs. This sheet has 27 fields already completed and, if your publication uses the default values already completed, you must complete the additional 17 fields.
Field definitions
Description of information fields used throughout the spreadsheet tabs that may not be immediately obvious to a user.
Attach Print Specs to PDF
For Acrobat 7.0, follow these steps: 1. Open the PDF. 2. Click on the Attachments tab next to the publication's bookmarks. A new section appears at the bottom of the PDF. 3. Click on the Add button in the bottom section of the PDF. 4. Browse to the MS Excel file with the print specs and add them to the PDF. For Acrobat 6.0, follow these steps: 1. Open the PDF. 2. Go to the backcover of the PDF. 3. Click on the Tools pull-down menu. 4. Click on this sequence of menu options - Advanced Commenting, Attach, Attach File Tool. A paper clip appears. 5. Click to put the paper clip somewhere on the backcover. The browse window appears. 6. Browse to the MS Excel file with the print specs and add them to the PDF. IMPORTANT: If you are using Acrobat 5.0 or earlier, please upgrade. If you are using Acrobat 8.0, please contact RRD about attaching print specs because RA has not tested this software version yet.
Chargeback Price
Sequentially Numbered Item?
Content File Location
Item Subtype
Page Qty
Sheets Qty
Thermal Tape Color
Trim Size Width
Trim Size Length
Publication Number
Publication Title
Min Order Qty
Multiple Order Qty
Binding/Stitching
Orientation
Page Count of Publication
CSS/JLS Production Stock
Paper Stock Type
Paper Stock Weight
Paper Stock Color
Glue Location
Fold Type
Fold At
Number of Pieces per Box
Comments
Part Number
Are these items being setup on dPrint? (Yes or No). If yes, Inv Mgmt to check "Print Management" flag on item setup.
The content/Comp # will be provided by the CSC once the spec files are loaded to the DAS (the files must be named with the WCSS item #). The content/comp# must be hardcoded to the Item message Field in WCSS. Must be a 10 Digit number that starts with an 8.
Required. Setting this to yes will allow warehouse product to ship out before the JIT item is completed. Setting this to no will hold all warehoused items until the printing of this item is complete. Please indicate Y or N.** Note: Each item with a Y will always ship separately even if produced at the same time as like items.
Optional. 15 Characters Max. If the WCSS number provided already exists in the system, then Inventory Management will assign a random WCSS number.
30 characters maximum.
Required. Which plant/Print Center will produce this item?
Required. To be provided from the producing plant for JIT s/u
Required: What is the plant code of the plant that has owning rights to the dPrint files? If produced at multiple plants there can be only one owning plant.
Required. What is the plant code of the facility that will produce this item? (see "Plant and Whse Codes" tab below)
Required. Enter one of the applicable product.
Method of packaging for publication shipment Click here for explanation of each value in the pull-down
Required. This field auto-calculates (transfer cost divided by .5). Used to determine Standard Cost on WCSS (which is 50% of the list price for these product codes).
Required. Transfer Cost per ordering/packaging unit of measure.
Required. Price that will be billed to customer upon order. If Price Breaks, enter "Price Breaks" and note them on separate spreadsheet.
Required. Replacement Cost per Packaging/ordering UOM.
Click here for an explanation of this field; otherwise, type NA.
Optional. Used to assist customer with internal Chargebacks to end users. (per packaging/ordering UOM)
IMPORTANT: This information must match the DocMan record. Click here for explanation of each value in the pull-down menu.
IMPORTANT: This information must match the DocMan record.
IMPORTANT: This information must match the DocMan record. Date on the publication.
Click here for explanation of each value in the pull-down menu.
Indicate Yes or No. Enter Yes if the item is a sequentially numbered item.
Describe the details behind the sequentially numbered item, such as: - Record Sequence Shipped: whse will record the sequence numbers that shipped - Ship in Sequence Record: required to ship products in particular sequence and the whse records the numbers
Required: Enter the word DIGITAL or the word OFFSET, which ever one describes the production pricing used for this item
Required: If PDF is to be retained in the DAS enter DAS in this field, if item is part of eCreate or Custom Docs put CUSTOM in this field.
Typically a Book. Click here for explanation of each value in the pull-down menu.
Click here for explanation of each value in the pull-down
Click here for explanation of each value in the pull-down menu.
Optional: Use when finished product stored in the warehouse is to be inserted into the construction of a JIT book.
IMPORTANT: Not Trim Size width This is the width of the paper on which the publication is printed.
IMPORTANT: Not Trim Size length This is the length of the paper on which the publication is printed.
Click here for explanation of how to determine the information required.
Click here for explanation of how to determine the information required.
Optional: Use when product is being printed on Shell Stock. Provide warehoused WCSS Item nu,mber of product to be used in the production of JIT item.
Click here for explanation of how to determine the information required.
The pull-down menu lists the most common choices. Click here for a full list of the available choices. If you use a choice not in the pull-down list, type the value in the cell below the pull-down menu.
If item uses tabs; otherwise, NA.
If needed; otherwise type NA.
If item used in a binder; otherwise, NA.
If item used in a binder; otherwise, NA.
If item used in a binder; otherwise, NA.
If item used in a binder; otherwise, NA.
If publication is thermal tape bound; otherwise, NA.
Click here to see the available finished trim sizes. The sizes are listed - width x length.
Click here to see the available finished trim sizes. The sizes are listed - width x length.
If publication is Book [B] and stapled; otherwise, NA.
Click here for a list of possible drill locations
If publication uses padding; otherwise, NA.
If publication is a notepad or message pad; otherwise, NA.
Click here for explanation of each value in the pull-down menu.
Click here for explanation of each value in the pull-down menu.
Use this column to list: - Cover Stock - Text Stock - Cover Ink - Text Ink Also use to indicate any other production or finishing requirements not provided in previous columns Click here for an explanation of the available Cover Stock, Cover Ink and Text Ink values.
List only if pubication is used in manufacturing; otherwise, leave blank.
See DocMan for the Cost Center selections associated with each Business Group.
RRD must provide this information
RRD must provide this information
RRD must provide this information
RRD must provide this information
&CItem Setup Sheet for Conversion Transfers
&LJIT-D-print Spreadsheet&CREF046&R&D &T
dPrint?
Content/Comp #
Chargeback Price
Sequentially Numbered Item?
Content File Location
Item Subtype
Page Qty
Sheets Qty
Thermal Tape Color
Trim Size Width
Trim Size Length
Publication Number
Publication Title
Min Order Qty
Multiple Order Qty
Binding/Stitching
Orientation
Page Count of Publication
CSS/JLS Production Stock
Paper Stock Type
Paper Stock Weight
Paper Stock Color
Glue Location
Fold Type
Fold At
Number of Pieces per Box
Comments
Part Number
Are these items being setup on dPrint? (Yes or No). If yes, Inv Mgmt to check "Print Management" flag on item setup.
The content/Comp # will be provided by the CSC once the spec files are loaded to the DAS (the files must be named with the WCSS item #). The content/comp# must be hardcoded to the Item message Field in WCSS. Must be a 10 Digit number that starts with an 8.
Required. Setting this to yes will allow warehouse product to ship out before the JIT item is completed. Setting this to no will hold all warehoused items until the printing of this item is complete. Please indicate Y or N.** Note: Each item with a Y will always ship separately even if produced at the same time as like items.
Optional. 15 Characters Max. If the WCSS number provided already exists in the system, then Inventory Management will assign a random WCSS number.
30 characters maximum.
Required. Which plant/Print Center will produce this item?
Required. To be provided from the producing plant for JIT s/u
Required: What is the plant code of the plant that has owning rights to the dPrint files? If produced at multiple plants there can be only one owning plant.
Required. What is the plant code of the facility that will produce this item? (see "Plant and Whse Codes" tab below)
Required. Enter one of the applicable product.
Method of packaging for publication shipment Click here for explanation of each value in the pull-down
Required. This field auto-calculates (transfer cost divided by .5). Used to determine Standard Cost on WCSS (which is 50% of the list price for these product codes).
Required. Transfer Cost per ordering/packaging unit of measure.
Required. Price that will be billed to customer upon order. If Price Breaks, enter "Price Breaks" and note them on separate spreadsheet.
Required. Replacement Cost per Packaging/ordering UOM.
Click here for an explanation of this field; otherwise, type NA.
Optional. Used to assist customer with internal Chargebacks to end users. (per packaging/ordering UOM)
IMPORTANT: This information must match the DocMan record. Click here for explanation of each value in the pull-down menu.
IMPORTANT: This information must match the DocMan record.
IMPORTANT: This information must match the DocMan record. Date on the publication.
Click here for explanation of each value in the pull-down menu.
Indicate Yes or No. Enter Yes if the item is a sequentially numbered item.
Describe the details behind the sequentially numbered item, such as: - Record Sequence Shipped: whse will record the sequence numbers that shipped - Ship in Sequence Record: required to ship products in particular sequence and the whse records the numbers
Required: Enter the word DIGITAL or the word OFFSET, which ever one describes the production pricing used for this item
Required: If PDF is to be retained in the DAS enter DAS in this field, if item is part of eCreate or Custom Docs put CUSTOM in this field.
Typically a Book. Click here for explanation of each value in the pull-down menu.
Click here for explanation of each value in the pull-down
Click here for explanation of each value in the pull-down menu.
Optional: Use when finished product stored in the warehouse is to be inserted into the construction of a JIT book.
IMPORTANT: Not Trim Size width This is the width of the paper on which the publication is printed.
IMPORTANT: Not Trim Size length This is the length of the paper on which the publication is printed.
Click here for explanation of how to determine the information required.
Click here for explanation of how to determine the information required.
Optional: Use when product is being printed on Shell Stock. Provide warehoused WCSS Item nu,mber of product to be used in the production of JIT item.
Click here for explanation of how to determine the information required.
The pull-down menu lists the most common choices. Click here for a full list of the available choices. If you use a choice not in the pull-down list, type the value in the cell below the pull-down menu.
If item uses tabs; otherwise, NA.
If needed; otherwise type NA.
If item used in a binder; otherwise, NA.
If item used in a binder; otherwise, NA.
If item used in a binder; otherwise, NA.
If item used in a binder; otherwise, NA.
If publication is thermal tape bound; otherwise, NA.
Click here to see the available finished trim sizes. The sizes are listed - width x length.
Click here to see the available finished trim sizes. The sizes are listed - width x length.
If publication is Book [B] and stapled; otherwise, NA.
Click here for a list of possible drill locations
If publication uses padding; otherwise, NA.
If publication is a notepad or message pad; otherwise, NA.
Click here for explanation of each value in the pull-down menu.
Click here for explanation of each value in the pull-down menu.
Use this column to list: - Cover Stock - Text Stock - Cover Ink - Text Ink Also use to indicate any other production or finishing requirements not provided in previous columns Click here for an explanation of the available Cover Stock, Cover Ink and Text Ink values.
List only if pubication is used in manufacturing; otherwise, leave blank.
20D-RN036A-EN-P
Release Notes - PowerFlex® 700S Drives with Phase II Control (4.002)
EA
1
NA
12/18/2007
5
B
SADDLE
PORTRAIT
HEAD2HEAD
4
12
3
PLAIN
20#
White
NA
NA
NA
NA
NA
NA
NA
8.5
11
SIDE
NA
NA
NA
NA
HALF
50
Text Stock = 20# White Opaque Bond Text Ink = Black
dPrint?
Content/Comp #
Chargeback Price
Sequentially Numbered Item?
Content File Location
Item Subtype
Page Qty
Sheets Qty
Thermal Tape Color
Trim Size Width
Trim Size Length
Publication Number
Publication Title
Min Order Qty
Multiple Order Qty
Binding/Stitching
Orientation
Page Count of Publication
CSS/JLS Production Stock
Paper Stock Type
Paper Stock Weight
Paper Stock Color
Glue Location
Fold Type
Fold At
Number of Pieces per Box
Comments
Part Number
Are these items being setup on dPrint? (Yes or No). If yes, Inv Mgmt to check "Print Management" flag on item setup.
The content/Comp # will be provided by the CSC once the spec files are loaded to the DAS (the files must be named with the WCSS item #). The content/comp# must be hardcoded to the Item message Field in WCSS. Must be a 10 Digit number that starts with an 8.
Required. Setting this to yes will allow warehouse product to ship out before the JIT item is completed. Setting this to no will hold all warehoused items until the printing of this item is complete. Please indicate Y or N.** Note: Each item with a Y will always ship separately even if produced at the same time as like items.
Optional. 15 Characters Max. If the WCSS number provided already exists in the system, then Inventory Management will assign a random WCSS number.
30 characters maximum.
Required. Which plant/Print Center will produce this item?
Required. To be provided from the producing plant for JIT s/u
Required: What is the plant code of the plant that has owning rights to the dPrint files? If produced at multiple plants there can be only one owning plant.
Required. What is the plant code of the facility that will produce this item? (see "Plant and Whse Codes" tab below)
Required. Enter one of the applicable product.
Method of packaging for publication shipment Click here for explanation of each value in the pull-down
Required. This field auto-calculates (transfer cost divided by .5). Used to determine Standard Cost on WCSS (which is 50% of the list price for these product codes).
Required. Transfer Cost per ordering/packaging unit of measure.
Required. Price that will be billed to customer upon order. If Price Breaks, enter "Price Breaks" and note them on separate spreadsheet.
Required. Replacement Cost per Packaging/ordering UOM.
Click here for an explanation of this field; otherwise, type NA.
Optional. Used to assist customer with internal Chargebacks to end users. (per packaging/ordering UOM)
IMPORTANT: This information must match the DocMan record. Click here for explanation of each value in the pull-down menu.
IMPORTANT: This information must match the DocMan record.
IMPORTANT: This information must match the DocMan record. Date on the publication.
Click here for explanation of each value in the pull-down menu.
Indicate Yes or No. Enter Yes if the item is a sequentially numbered item.
Describe the details behind the sequentially numbered item, such as: - Record Sequence Shipped: whse will record the sequence numbers that shipped - Ship in Sequence Record: required to ship products in particular sequence and the whse records the numbers
Required: Enter the word DIGITAL or the word OFFSET, which ever one describes the production pricing used for this item
Required: If PDF is to be retained in the DAS enter DAS in this field, if item is part of eCreate or Custom Docs put CUSTOM in this field.
Typically a Book. Click here for explanation of each value in the pull-down menu.
Click here for explanation of each value in the pull-down
Click here for explanation of each value in the pull-down menu.
Optional: Use when finished product stored in the warehouse is to be inserted into the construction of a JIT book.
IMPORTANT: Not Trim Size width This is the width of the paper on which the publication is printed.
IMPORTANT: Not Trim Size length This is the length of the paper on which the publication is printed.
Click here for explanation of how to determine the information required.
Click here for explanation of how to determine the information required.
Optional: Use when product is being printed on Shell Stock. Provide warehoused WCSS Item nu,mber of product to be used in the production of JIT item.
Click here for explanation of how to determine the information required.
The pull-down menu lists the most common choices. Click here for a full list of the available choices. If you use a choice not in the pull-down list, type the value in the cell below the pull-down menu.
If item uses tabs; otherwise, NA.
If needed; otherwise type NA.
If item used in a binder; otherwise, NA.
If item used in a binder; otherwise, NA.
If item used in a binder; otherwise, NA.
If item used in a binder; otherwise, NA.
If publication is thermal tape bound; otherwise, NA.
Click here to see the available finished trim sizes. The sizes are listed - width x length.
Click here to see the available finished trim sizes. The sizes are listed - width x length.
If publication is Book [B] and stapled; otherwise, NA.
Click here for a list of possible drill locations
If publication uses padding; otherwise, NA.
If publication is a notepad or message pad; otherwise, NA.
Click here for explanation of each value in the pull-down menu.
Click here for explanation of each value in the pull-down menu.
Use this column to list: - Cover Stock - Text Stock - Cover Ink - Text Ink Also use to indicate any other production or finishing requirements not provided in previous columns Click here for an explanation of the available Cover Stock, Cover Ink and Text Ink values.
List only if pubication is used in manufacturing; otherwise, leave blank.
EA
1
See DocMan for the Cost Center selections associated with each Business Group.
5
B
PERFECT
PORTRAIT
HEAD2HEAD
2
PLAIN
20#
White
NA
NA
NA
NA
NA
NA
NA
8.5
11
NA
1/4"
3LEFT
LEFT
NA
NA
NA
RRD must provide this information
Cover Stock = 90# White Index Text Stock = 20# White Opaque Bond Cover Ink = Black Text Ink = Black
NA
dPrint?
Content/Comp #
Chargeback Price
Sequentially Numbered Item?
Content File Location
Item Subtype
Page Qty
Sheets Qty
Thermal Tape Color
Trim Size Width
Trim Size Length
Publication Number
Publication Title
Min Order Qty
Multiple Order Qty
Binding/Stitching
Orientation
Page Count of Publication
CSS/JLS Production Stock
Paper Stock Type
Paper Stock Weight
Paper Stock Color
Glue Location
Fold Type
Fold At
Number of Pieces per Box
Comments
Part Number
Are these items being setup on dPrint? (Yes or No). If yes, Inv Mgmt to check "Print Management" flag on item setup.
The content/Comp # will be provided by the CSC once the spec files are loaded to the DAS (the files must be named with the WCSS item #). The content/comp# must be hardcoded to the Item message Field in WCSS. Must be a 10 Digit number that starts with an 8.
Required. Setting this to yes will allow warehouse product to ship out before the JIT item is completed. Setting this to no will hold all warehoused items until the printing of this item is complete. Please indicate Y or N.** Note: Each item with a Y will always ship separately even if produced at the same time as like items.
Optional. 15 Characters Max. If the WCSS number provided already exists in the system, then Inventory Management will assign a random WCSS number.
30 characters maximum.
Required. Which plant/Print Center will produce this item?
Required. To be provided from the producing plant for JIT s/u
Required: What is the plant code of the plant that has owning rights to the dPrint files? If produced at multiple plants there can be only one owning plant.
Required. What is the plant code of the facility that will produce this item? (see "Plant and Whse Codes" tab below)
Required. Enter one of the applicable product.
Method of packaging for publication shipment Click here for explanation of each value in the pull-down
Required. This field auto-calculates (transfer cost divided by .5). Used to determine Standard Cost on WCSS (which is 50% of the list price for these product codes).
Required. Transfer Cost per ordering/packaging unit of measure.
Required. Price that will be billed to customer upon order. If Price Breaks, enter "Price Breaks" and note them on separate spreadsheet.
Required. Replacement Cost per Packaging/ordering UOM.
Click here for an explanation of this field; otherwise, type NA.
Optional. Used to assist customer with internal Chargebacks to end users. (per packaging/ordering UOM)
IMPORTANT: This information must match the DocMan record. Click here for explanation of each value in the pull-down menu.
IMPORTANT: This information must match the DocMan record.
IMPORTANT: This information must match the DocMan record. Date on the publication.
Click here for explanation of each value in the pull-down menu.
Indicate Yes or No. Enter Yes if the item is a sequentially numbered item.
Describe the details behind the sequentially numbered item, such as: - Record Sequence Shipped: whse will record the sequence numbers that shipped - Ship in Sequence Record: required to ship products in particular sequence and the whse records the numbers
Required: Enter the word DIGITAL or the word OFFSET, which ever one describes the production pricing used for this item
Required: If PDF is to be retained in the DAS enter DAS in this field, if item is part of eCreate or Custom Docs put CUSTOM in this field.
Typically a Book. Click here for explanation of each value in the pull-down menu.
Click here for explanation of each value in the pull-down
Click here for explanation of each value in the pull-down menu.
Optional: Use when finished product stored in the warehouse is to be inserted into the construction of a JIT book.
IMPORTANT: Not Trim Size width This is the width of the paper on which the publication is printed.
IMPORTANT: Not Trim Size length This is the length of the paper on which the publication is printed.
Click here for explanation of how to determine the information required.
Click here for explanation of how to determine the information required.
Optional: Use when product is being printed on Shell Stock. Provide warehoused WCSS Item nu,mber of product to be used in the production of JIT item.
Click here for explanation of how to determine the information required.
The pull-down menu lists the most common choices. Click here for a full list of the available choices. If you use a choice not in the pull-down list, type the value in the cell below the pull-down menu.
If item uses tabs; otherwise, NA.
If needed; otherwise type NA.
If item used in a binder; otherwise, NA.
If item used in a binder; otherwise, NA.
If item used in a binder; otherwise, NA.
If item used in a binder; otherwise, NA.
If publication is thermal tape bound; otherwise, NA.
Click here to see the available finished trim sizes. The sizes are listed - width x length.
Click here to see the available finished trim sizes. The sizes are listed - width x length.
If publication is Book [B] and stapled; otherwise, NA.
Click here for a list of possible drill locations
If publication uses padding; otherwise, NA.
If publication is a notepad or message pad; otherwise, NA.
Click here for explanation of each value in the pull-down menu.
Click here for explanation of each value in the pull-down menu.
Use this column to list: - Cover Stock - Text Stock - Cover Ink - Text Ink Also use to indicate any other production or finishing requirements not provided in previous columns Click here for an explanation of the available Cover Stock, Cover Ink and Text Ink values.
List only if pubication is used in manufacturing; otherwise, leave blank.
PK
1
See DocMan for the Cost Center selections associated with each Business Group.
NA
PORTRAIT
HEAD2HEAD
GLOSS TEXT
NA
NA
NA
NA
NA
NA
NA
8.25
11
NA
NA
NA
NA
NA
NA
NA
Producing Plant
Job Number
Replenishing Plant
Plant Code
Product Code
Packaging/Ordering UOM
Chargeback Price
Sequentially Numbered Item?
Content File Location
Item Subtype
Page Qty
Sheets Qty
Thermal Tape Color
Trim Size Width
Trim Size Length
Publication Number
Publication Title
Min Order Qty
Multiple Order Qty
Binding/Stitching
Orientation
Page Count of Publication
CSS/JLS Production Stock
Paper Stock Type
Paper Stock Weight
Paper Stock Color
Glue Location
Fold Type
Fold At
Number of Pieces per Box
Comments
Part Number
Are these items being setup on dPrint? (Yes or No). If yes, Inv Mgmt to check "Print Management" flag on item setup.
The content/Comp # will be provided by the CSC once the spec files are loaded to the DAS (the files must be named with the WCSS item #). The content/comp# must be hardcoded to the Item message Field in WCSS. Must be a 10 Digit number that starts with an 8.
Required. Setting this to yes will allow warehouse product to ship out before the JIT item is completed. Setting this to no will hold all warehoused items until the printing of this item is complete. Please indicate Y or N.** Note: Each item with a Y will always ship separately even if produced at the same time as like items.
Optional. 15 Characters Max. If the WCSS number provided already exists in the system, then Inventory Management will assign a random WCSS number.
30 characters maximum.
Required. Which plant/Print Center will produce this item?
Required. To be provided from the producing plant for JIT s/u
Required: What is the plant code of the plant that has owning rights to the dPrint files? If produced at multiple plants there can be only one owning plant.
Required. What is the plant code of the facility that will produce this item? (see "Plant and Whse Codes" tab below)
Required. Enter one of the applicable product.
Method of packaging for publication shipment Click here for explanation of each value in the pull-down
Required. This field auto-calculates (transfer cost divided by .5). Used to determine Standard Cost on WCSS (which is 50% of the list price for these product codes).
Required. Transfer Cost per ordering/packaging unit of measure.
Required. Price that will be billed to customer upon order. If Price Breaks, enter "Price Breaks" and note them on separate spreadsheet.
Required. Replacement Cost per Packaging/ordering UOM.
Click here for an explanation of this field; otherwise, type NA.
Optional. Used to assist customer with internal Chargebacks to end users. (per packaging/ordering UOM)
IMPORTANT: This information must match the DocMan record. Click here for explanation of each value in the pull-down menu.
IMPORTANT: This information must match the DocMan record.
IMPORTANT: This information must match the DocMan record. Date on the publication.
Click here for explanation of each value in the pull-down menu.
Indicate Yes or No. Enter Yes if the item is a sequentially numbered item.
Describe the details behind the sequentially numbered item, such as: - Record Sequence Shipped: whse will record the sequence numbers that shipped - Ship in Sequence Record: required to ship products in particular sequence and the whse records the numbers
Required: Enter the word DIGITAL or the word OFFSET, which ever one describes the production pricing used for this item
Required: If PDF is to be retained in the DAS enter DAS in this field, if item is part of eCreate or Custom Docs put CUSTOM in this field.
Typically a Book. Click here for explanation of each value in the pull-down menu.
Click here for explanation of each value in the pull-down
Click here for explanation of each value in the pull-down menu.
Optional: Use when finished product stored in the warehouse is to be inserted into the construction of a JIT book.
IMPORTANT: Not Trim Size width This is the width of the paper on which the publication is printed.
IMPORTANT: Not Trim Size length This is the length of the paper on which the publication is printed.
Click here for explanation of how to determine the information required.
Click here for explanation of how to determine the information required.
Optional: Use when product is being printed on Shell Stock. Provide warehoused WCSS Item nu,mber of product to be used in the production of JIT item.
Click here for explanation of how to determine the information required.
The pull-down menu lists the most common choices. Click here for a full list of the available choices. If you use a choice not in the pull-down list, type the value in the cell below the pull-down menu.
If item uses tabs; otherwise, NA.
If needed; otherwise type NA.
If item used in a binder; otherwise, NA.
If item used in a binder; otherwise, NA.
If item used in a binder; otherwise, NA.
If item used in a binder; otherwise, NA.
If publication is thermal tape bound; otherwise, NA.
Click here to see the available finished trim sizes. The sizes are listed - width x length.
Click here to see the available finished trim sizes. The sizes are listed - width x length.
If publication is Book [B] and stapled; otherwise, NA.
Click here for a list of possible drill locations
If publication uses padding; otherwise, NA.
If publication is a notepad or message pad; otherwise, NA.
Click here for explanation of each value in the pull-down menu.
Click here for explanation of each value in the pull-down menu.
Use this column to list: - Cover Stock - Text Stock - Cover Ink - Text Ink Also use to indicate any other production or finishing requirements not provided in previous columns Click here for an explanation of the available Cover Stock, Cover Ink and Text Ink values.
List only if pubication is used in manufacturing; otherwise, leave blank.
PK
1
See DocMan for the Cost Center selections associated with each Business Group.
100
B
SADDLE
PORTRAIT
HEAD2HEAD
White
NA
NA
NA
NA
NA
NA
SIDE
NA
NA
NA
NA
50
NA
NA
Multiple Order Qty
Separate methods of ordering same item. For example, if an item is packaged 50 per pad / 5 pads per carton. You can set the order qty as 50 each (one pad) or 250 each (1 ctn)
Business Group
The business group that the publication supports. Your choice here determines the list you choose from for Cost Center.
Corporate/Business Development
Max Order Quantity
Presale items = 100
Postsale items = 5
NOTE: You can use other quantities but the delivery may take a bit longer because a system admin must approve it.
Item Category - Form (F) or Book (B)
Form (F) = Any publication that is a single sheet (i.e., 1 or 2 pages), an envelope or carbonless form.
Book (B) = Any publication that contains 3 or more pages.
Binding/Stitching
CARBONLESS
CUTSHEET
ENVELOPE
LOOSE
Sides Printed
Head2Head = Most common; Double-sided printing with headers on both pages lining up at the top of the page
Simplex = Single-sided printing
Head2Toe = Least common; Double-sided printing with header on one page lining up with the footer on the other page
Number of Forms to a Sheet
Number of publication pages printed on a sheet of paper at the printer. For example, if a 4-page, 8.5 x 11 publication is printed on the front and back sides of an 11 x 17 sheet of paper that is folded in half, the Number of Forms to a Sheet = 4.
Number of Sheets Required to Print
Number of sheets of paper required to print the publication. For example, if a 16-page, 8.5 x 11 publication is printed on the front and back sides of four 11 x 17 sheets of paper that are folded in half and saddle stitched together, the Number of Sheets Required to Print = 4.
Paper Stock Type
Paper Stock Color
11 x 17
8.5 x 11
8.25 x 10.875
8.375 x 10.875
9 x 12
Drilling Locations
Publication length
Type in PMS color
Type in PMS color
Type in PMS colors