POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one...

63
POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power range of 0.5 to 200VA. Hahn has a totally manufacturing capacity of approximately 150, 000 transformers per day, divided into three factories, two in Germany and one in Ukraina. With 35 years of experience, Hahn is in the front edge of product development, quality and delivery precision. Hahn has a stock of more than 500 different standard types for immediately delivery. But if none of these 500 standard types doesn't fit to your application also customer specific types are very much welcomed from quantities of 100 pcs per shipment. Approvals Most of the internationals approvals inclusive the new European standard EN61558, which fully complies with IEC950. By default, Hahn is manufacturing all transformers for use in ta 70. BV20 Very small power transformer with the sizes (l * w * h) 21.7 * 22.6 * 15.0 mm (0.35VA) or 21.7 * 22.6 * 19.0 mm (0.5VA) with input voltage at 400V or less. EI30-EI96 EI30 to EI96 are standard designs of core type EI. The most common series is EI30, has the size (l * w * h) 32.5 * 27.5 * h mm where h is related to the power rating. 0.5 - 3.2 VA correspond to 15.2 - 33.8 mm. EI38 – EI96 has a power range of 3.2 to 200VA. The EI series are available as PCB mounted, with flat pin connectors (RAST5) or screwed connection. Input voltage up to 500V. EI30 to the left and BV20 to the right UI30 – UI48 Low profile transformers with printed circuit board design, power range of 1 to 60 VA. Sizes are available from (l * w * h) 29.1 * 33.5 * 14.9 mm (1VA) to 70 * 8 * 38.5 mm (60VA). Input voltage up to 500V. UI39 to the left and UI30 to the right GENERAL TECHNICAL INFORMATION Thermal energy in transformers The heat is a transformers enemy no1. Too much self generating heat and to high ambient temperature can seriously damage the transformer and lead to short circuit and voltage breakdown. Hahn’s transformers are designed with these problems in consideration. To increase the heat dissipation capability and dielectric strength the transformers are winded with a heat-resisting copper wire (180°C) and casted with heat resistant epoxy resin (135°C). To guarantee a non- porous casting and a one hundred percentage adherence of the epoxy resin to the copper wire, the winding are casted in absolute vacuum in a three-stage process To reduce the self-heating procedure, the EI- series core is welded, which will lead to a 40% increase of power within a specific core size, versus ordinary snap-core. Before delivery, there is a 100% test of the primary and secondary voltage at no load and at rated load, no load current, isolation voltage and footprint. www.flexitron.se 1/63

Transcript of POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one...

Page 1: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

POWER TRANSFORMERS

Hahn, Germany

Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power range of 0.5 to 200VA. Hahn has a totally manufacturing capacity of approximately 150, 000 transformers per day, divided into three factories, two in Germany and one in Ukraina. With 35 years of experience, Hahn is in the front edge of product development, quality and delivery precision. Hahn has a stock of more than 500 different standard types for immediately delivery. But if none of these 500 standard types doesn't fit to your application also customer specific types are very much welcomed from quantities of 100 pcs per shipment. Approvals Most of the internationals approvals inclusive the new European standard EN61558, which fully complies with IEC950. By default, Hahn is manufacturing all transformers for use in ta 70.

BV20 Very small power transformer with the sizes (l*w*h) 21.7*22.6*15.0 mm (0.35VA) or 21.7*22.6*19.0 mm (0.5VA) with input voltage at 400V or less. EI30-EI96 EI30 to EI96 are standard designs of core type EI. The most common series is EI30, has the size (l*w*h) 32.5*27.5* h mm where h is related to the power rating. 0.5 - 3.2 VA correspond to 15.2 - 33.8 mm. EI38 – EI96 has a power range of 3.2 to 200VA. The EI series are available as PCB mounted, with flat pin connectors (RAST5) or screwed connection. Input voltage up to 500V.

EI30 to the left and BV20 to the right

UI30 – UI48 Low profile transformers with printed circuit board design, power range of 1 to 60 VA. Sizes are available from (l*w*h) 29.1*33.5*14.9 mm (1VA) to 70*8*38.5 mm (60VA). Input voltage up to 500V.

UI39 to the left and UI30 to the right

GENERAL TECHNICAL INFORMATION

Thermal energy in transformers The heat is a transformers enemy no1. Too much self generating heat and to high ambient temperature can seriously damage the transformer and lead to short circuit and voltage breakdown. Hahn’s transformers are designed with these problems in consideration. To increase the heat dissipation capability and dielectric strength the transformers are winded with a heat-resisting copper wire (180°C) and casted with heat resistant epoxy resin (135°C). To guarantee a non-porous casting and a one hundred percentage adherence of the epoxy resin to the copper wire, the winding are casted in absolute vacuum in a three-stage process To reduce the self-heating procedure, the EI-series core is welded, which will lead to a 40% increase of power within a specific core size, versus ordinary snap-core. Before delivery, there is a 100% test of the primary and secondary voltage at no load and at rated load, no load current, isolation voltage and footprint.

www.flexitron.se 1/63

Page 2: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Standard and low-profile design Standard design, series EI, is generally cheaper to produce than the low-profile series, UI, this because UI-series has two bobbins instead of one. The price difference is 50 to 80 %. The UI-series has a lower design then EI (see the overview table). Normally there is an isolation advantage with two coil formers (series UI) instead of one (series EI), but in case they are vacuum casted both series complies 100% with the class II isolation. Standard or customer specific Hahn’s stock of standard transformers is located close to Frankfurt, Germany and contains over 500 different types. We need five days to delivery from this stock to your doorstep. Beside this, ELFA is stocking a large number of these types in Sweden. Hahn’s productions equipment can easily be setup to produce customer specific transformers. So they can easily produce transformers with other demands then standard, when ordering at least one hundred transformers. Fore example two secondary winding with different voltage, higher isolating demands or 500V primary voltage. The customer specific transformers has a delivery time of six weeks and don’t have any considerable extra cost.

Isolating-classes Most of all electronic equipments today are manufactured in so called class II design, which means that no protective earth is needed. To accomplish this, the transformer needs satisfactory isolation between the primary, secondary and the core. EN61558 demands that the transformer shall withstand a test voltage at 4kV. On account of Hahn’s excellent cast technology, all transformers are tested at 6kV, only to give an extra safety margin. Further demands are that the air- and the creepage distance are larger than 8mm. With Hahn’s cast-technology the core will be considered as a homogeneous mass without any internal air- and creepage distance.

Approval Hahn’s transformers comply with the requirements of EN61558 and IEC950. Most of the transformers are approved by a third part certification by VDE/KEMA and UL/CSA and have the right to be marked with ENEC and UL. The material and the design are the same in all transformers and therefore it is easy to get approvals in new applications. Temperature classes The temperature class ta 40/F and ta 70/F indicate the maximum ambient temperature in degree Celsius at max load. Most of Hahn’s transformers are classified to T70/F. At max load, the self-heating is abut 30-40°C, with gives a total temperature of 100-110°C. All of Hahn’s transformers can manage a self-temperature at 130°C without cause any damage. Short-circuit proof Up to 3,2VA all Hahn’s transformers are inherently short-circuit proof. Which means that the transformer is designed so it can manage the short-circuit temperature during at least 8 days without getting damaged. The temperature must not exceed 175°C according to EN61558. This means that no fuse is needed on the primary side. For larger transformers (3.2 up to 10VA) we recommend that PTC resistor is used instead of glass tube fuse. No load voltage No load voltage for short circuit proof transformers is normally 40-85% higher then the nominal voltage. This because the high internal resistance on the secondary side. The high resistance is needed to limit the short circuit current so that the temperature rise at short circuit not will exceed the allowed limit. The maximum allowed temperature rise at short circuit is 135°K for T40 and 105°K for T70 transformers. That means that the T70 internal impedance is greater then the impedance on a T40 transformer, and the no load voltage is higher at T70 then a T40. Non- short circuit proof transformer has a no load voltage that is 20 -30% of the nominal voltage.

www.flexitron.se 2/63

Page 3: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Technical data Hipot: 6000V Isolation secondary/ secondary: 500V Air- and the creepage distance: >10mm Isolations resistance: >5MΩ Max ambient temperature at max continuous load: 40°C or 70°C No load voltage for short circuit proof transformers max 3,2VA (of nominal voltage)

Temp. class T70/F 60-85% Temp. class T40/F 40-50% No load voltage for no-short circuit proof transformers (of nominal voltage)

3,2-10VA appr 30% 10-50VA appr 20% Max primary overvoltage: 10% Voltage tolerance, secondary side at 20°C: +/- 5% Frequency range: 50-60Hz

OVERVIEW TABLE

Max power

Series Core ta40 ta70 ta70*

Size

(h)

(mm)

Surface

area

(mm)

BV201 EE20 0,35VA 15,0 21,7x22,6 BV202 EE20 0,50VA 19,0 21,7x22,6 EI301 EI30/5 0,6VA 0,7VA 0,65VA 15,2 32,5x27,5 EI302 EI30/10,5 1,8VA 1,5VA 1,8VA 21,8 32,5x27,5 EI307 EI30/11,5 2,2VA 1,8VA 1,8VA 22,1 32,5x27,5 EI303 EI30/12,5 2,3VA 1,9VA 2,3VA 24,0 32,5x27,5 EI304 EI30/15,5 2,6VA 2,1VA 2,4VA 27,0 32,5x27,5 EI305 EI30/18 3,0VA 2,3VA 2,7VA 29,8 32,5x27,5 EI306 EI30/23 3,2VA 2,6VA 3,4VA 33,8 32,5x27,5 EI381 EI38/7,5 2,5VA 22,1 41,0x35,1 EI382 EI38/13,6 4,5VA 28,1 41,0x35,1 EI383 EI38/16,3 6,0VA 30,8 41,0x35,1 EI421 EI42/8,5 3VA 26,2 44,0x37,0 EI422 EI42/14,8 6VA 32,3 44,0x37,0 EI423 EI42/20,0 10VA 38,0 44,0x37,0

EI – series standard design

www.flexitron.se 3/63

Page 4: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

EI480 EI48/12,5 7VA 30,2 50,3x42,1 EI481 EI48/16,8 10VA 34,6 50,3x42,1 EI482 EI48/20,5 12VA 38,5 50,3x42,1 EI483 EI48/25,5 15VA 44,0 50,3x42,1 EI540 EI54/ 14 12VA 35,0 55,9x47,5 EI541 EI54/ 18,8 16VA 38,8 55,9x47,5 EI542 EI54/ 23 20VA 43,2 55,9x47,5 EI543 EI54/ 25,5 22VA 47,4 55,9x47,5 EI600 EI60/16 17VA 40,5 63,6x53,6 EI601 EI60/21 20VA 46,8 63,6x53,6 EI602 EI60/25,5 28VA 51,3 63,6x53,6 EI603 EI60/30,5 30VA 56,3 63,6x53,6 EI604 EI60/35 35VA 59,4 63,6x53,6 * with termo fuse

UI – series low profile

Max power

Series Core ta70 ta40

Size

(h)

(mm)

Surface

area

(mm)

UI21 UI21/7,3 1VA 14,9 29x33,5 UI301 UI30/5,5 3VA 17,8 44x53 UI302 UI30/7,5 4VA 19,8 44x53 UI303 UI30/10,5 6VA 22,8 44x53 UI304 UI30/16,5 10VA 28,8 44x53 UI305 UI30/26 16VA 37,6 44x53 UI392 UI39/8 10VA 23 57x68 UI393 UI39/10,5 14VA 25,2 57x68 UI394 UI39/13,5 18VA 28,5 57x68 UI395 UI39/17 24VA 32 57x68 UI396 UI39/21 30VA 36 57x68 UI481 UI48/17 40VA 38,7 71x84 UI482 UI48/26 60VA 47,9 71x84

www.flexitron.se 4/63

Page 5: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Over-load protection As a protection against overload we recommend the use of PTC resistors. If the transformer only has one secondary winding the PTC resistor can be connected to the primary side. In cases with more then one secondary winding, one PTC resistor must be connected to each secondary winding. In the table below they are columns for Imax depending on the ambient temperature (@ta25 and ta70). If the ambient temperature are between 25˚C and 70˚C all values between can be interpolated. For currents out of range, a glass-tube fuse can be used.

PTC resistors manufacturer EPCOS

Primary protection Max 265V RMS, T ref. 125°C

Type

Diam

(mm)

Imax (mA)

@ta25

Imax (mA)

@ta70 Rlow(Ω) EPCOS Part No

C890 4 30 19,5 150 B59890-C120-A70

C883 6,5 35 22,75 120 B59883-C120-A70

C875 9 55 35,75 65 B59875-C120-A70

C880 6,5 55 35,75 70 B59880-C120-A70

C874 9 60 39 55 B59874-C120-A70

C873 9 70 45,5 45 B59873-C120-A70

C872 9 80 52 35 B59872-C120-A70

C870 9 100 65 25 B59870-C120-A70

C860 11 140 91 15 B59860-C120-A70

C850 13,5 200 130 8 B59850-C120-A70

C840 17,5 330 214,5 6 B59840-C120-A70

C830 22 460 299 3,7 B59830-C120-A70

C810 26 650 422,5 2,6 B59810-C120-A70

Secondary protection

Max 30V RMS, T ref. 120°C

Type Diam

(mm)

Imax (mA)

@ta25

Imax (mA)

@ta70 Rlow(Ω) EPCOS Part No

C995 4 120 78 13 B59995-C120-A70

C985 6,5 250 162,5 4,6 B59985-C120-A70

C975 9 450 292,5 1,8 B59975-C120-A70

C965 11 600 390 1,2 B59965-C120-A70

C955 13,5 850 552,5 0,8 B59955-C120-A70

C945 17,5 1300 845 0,45 B59945-C120-A70

C935 22 1800 1170 0,3 B59935-C120-A70

C915 26 2500 1625 0,2 B59915-C120-A70

Max 80V RMS, T ref 120°C

Type Diam

(mm)

Imax (mA)

@ta25

Imax (mA)

@ta70 Rlow(Ω) EPCOS Part No

C990 4 50 32,5 55 B59990-C120-A70

C980 6,5 85 55,25 25 B59980-C120-A70

C970 9 150 97,5 9,4 B59970-C120-A70

C960 11 250 162,5 5,6 B59960-C120-A70

C950 13,5 320 208 3,7 B59950-C120-A70

C940 17,5 450 292,5 2,3 B59940-C120-A70

C930 22 700 455 1,65 B59930-C120-A70

C910 26 1000 650 0,9 B59910-C120-A70 www.flexitron.se 5/63

Page 6: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

PTC resistor manufacturer BC Components

Primary protection Max 265V RMS, T ref 140°C

Type

2322

Diam

(mm)

Imax (mA)

@ta25

Imax (mA)

@ta70 Rlow(Ω)

ELFA Part

No

660 #2893 5 28 21 500

660 #3993 5 39 29 260

660 #6393 5 63 47 120 60-265-53

660 #7693 5 76 57 85

660 #9593 5 95 71 56

661 #1113 7 110 82 48 60-265-87

661 #1413 7 140 105 29 60-265-95

661 #1713 8,5 170 127 22 60-266-03

661 #1913 8,5 190 142 18 60-266-11

662 #2113 10,5 210 157 17

662 #2513 10,5 250 187 12 60-266-37

662 #2813 12,5 280 210 11

662 #3213 12,5 320 240 8,4 60-266-52

663 #4013 16,5 400 300 6,6

663 #4913 16,5 490 367 4,4 60-266-78

664 #4013 20,5 590 443 4

663 #4013 20,5 700 525 2,8

Secondary protection Max 30V RMS, T ref 140°C

Type

2322

Diam

(mm)

Imax (mA)

@ta25

Imax (mA)

@ta70 Rlow(Ω)

ELFA Part

No

660 #9491 4,6 94 71 50

660 #1311 4,6 130 98 25

660 #1811 4,6 180 135 13

660 #2711 4,6 270 203 6 60-263-30

661 #3211 6,5 320 240 5

661 #4111 6,5 410 308 3 60-263-55

661 #4711 8,5 470 353 2,5

661 #5411 8,5 540 405 1,9 60-263-71

662 #6111 10,5 610 458 1,7

662 #7011 10,5 700 525 1,3 60-263-97

662 #8311 12,5 830 623 1,1

662 #9211 12,5 920 690 0,9 60-264-13

663 #1121 16,5 1170 878 0,7

663 #1321 16,5 1390 1043 0,5 60-264-39

664 #1721 20,5 1770 1328 0,4

664 #2021 20,5 2050 1538 0,3

www.flexitron.se 6/63

Page 7: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Primary: 12 - 240V~ ±10% 50-60Hz

Secondary: 6 - 24V~, ±5%

Power: 0,35VA

Temperature class: ta70/B

Isolation: 4kV/10mm/classII

Standard: EN 61558

Approvals: ENEC (Europe)

UL/CSA (USA, Canada)

Overload protection: Not needed

Short circuit proof.

Test: 100% (all individuals)

Weight: 25 g

Single secondary voltage 0.35VA ta70/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

BV201 0106 12V 1-4 6V 58 6-7 10,1V

BV201 0129 12V 1-4 12V 29 6-7 20,3V

BV201 0107 12V 1-4 24V 15 6-7 36,7V

BV201 0109 24V 1-4 12V 19 6-7 20,3V

BV201 0124 110V 1-4 6V 58 6-7 10,1V

BV201 0111 110V 1-4 12V 29 6-7 20,5V

BV201 0112 110V 1-4 15V 23 6-7 26,6V

BV201 0113 110V 1-4 24 15 6-7 36,8V

BV201 0141 120V 1-4 6V 58 6-7 10,1V

BV201 0128 230 1-4 1x6 58 6-7 1x10.0

BV201 0143 230 1-4 1x7.5 47 6-7 1x12.6

BV201 0136 230 1-4 1x9 39 6-7 1x14.4

BV201 0145 230 1-4 1x12 29 6-7 1x20.8

BV201 0147 230 1-4 1x15 23 6-7 1x26.1

BV201 0149 230 1-4 1x18 19 6-7 1x30.4

BV201 0150 230 1-4 1x21 17 6-7 1x36.0

BV201 0135 230 1-4 1x24 15 6-7 1x36.8

SERIES BV201 - 0,35VA

Primary

Part No

Secondary

Short circuit proof vacuumed casted safety PCB transformer. With single or dual secondary

windings. If there are two secondary windings they can be both serial and parallel connected.

2*115 V on the primary side on request.

15

22

3x5,0

1 2 3 4

5678

BV201

15

23

Prim

Sec

Bottom view Equipped pinsSoldering pin

0,6x0,5

Single secondary

winding

Dual secondarywindings

[mm]

P

S

1 2 3 4

5678

1 2 3 4

5678

P

S

www.flexitron.se 7/63

Page 8: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Single secondary voltage 0.35VA ta70/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

BV201 0127 240V 1-4 6V 58 6-7 10,1V

BV201 0151 240V 1-4 9V 39 6-7 14,4V

BV201 0133 240V 1-4 12V 29 6-7 20,8V

BV201 0138 240V 1-4 15V 23 6-7 26,5V

BV201 0140 240V 1-4 18V 19 6-7 30V

Dual secondary voltage 0.35VA ta70/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

BV201 0108 12V 1-4 2x9V 19 5-6/7-8 2x16V

BV201 0110 24V 1-4 2x12V 15 5-6/7-8 2x19,7V

BV201 0125 110V 1-4 2x6V 29 5-6/7-8 2x10,4V

BV201 0142 230 1-4 2x6 29 6-7 2x10.4

BV201 0144 230 1-4 2x9 19 6-7 2x16.0

BV201 0146 230 1-4 2x12 15 6-7 2x19.7

BV201 0148 230V 1-4 2x15V 12 5-6/7-8 2x25V

Primary

Part No

Secondary

Secondary

Part No

Primary

www.flexitron.se 8/63

Page 9: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Primary: 12 - 400V~ ±10% 50-60Hz

Secondary: 6 - 24V~, ±5%

Power: 0,50VA

Temperature class: ta70/B

Isolation: 4kV/10mm/classII

Standard: EN 61558

Approvals: ENEC (Europe)

UL/CSA (USA, Canada)

Overload protection: Not needed

Short circuit proof.

Test: 100% (all individuals)

Weight: 35 g

Single secondary voltage 0.50VA ta70/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

BV202 0154 230 1-4 1x6 83 6-7 1x10.2

BV202 0156 230 1-4 1x7.5 67 6-7 1x12.8

BV202 0157 230 1-4 1x9 55 6-7 1x15.4

BV202 0159 230 1-4 1x12 42 6-7 1x20.6

BV202 0161 230 1-4 1x15 33 6-7 1x25.9

BV202 0162 230 1-4 1x18 28 6-7 1x30.9

BV202 0163 230 1-4 1x21 24 6-7 1x36.2

BV202 0164 230 1-4 1x24 21 6-7 1x41.2

BV202 0168 400V 1-4 6V 58 6-7 8,8V

BV202 0170 400V 1-4 7,5V 47 6-7 11V

BV202 0171 400V 1-4 9V 39 6-7 12,9V

BV202 0174 400V 1-4 15V 23 6-7 21,5V

BV202 0175 400V 1-4 18V 23 6-7 26,3V

BV202 0176 400V 1-4 24V 14 6-7 34,5V

SERIES BV202 0,5VA

Short circuit proof vacuumed casted safety PCB transformer. With single or dual secondary

windings. If there are two secondary windings they can be both serial and parallel

connected. 2*115 V on the primary side on request.

Part No

Primary Secondary

15

22

3x5,0

1 2 3 4

5678

BV202

19

23

P

S

1 2 3 4

5678

1 2 3 4

5678

P

S

Prim

Sec

Bottom view Equipped pinsSoldering pin 0,6x0,5

Single secondary

winding

Dual secondary

windings[mm]

www.flexitron.se 9/63

Page 10: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Dual secondary voltage 0.50VA ta70/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

BV202 0155 230 1-4 2x6 42 5-6/7-8 2x10.2

BV202 0158 230 1-4 2x9 28 5-6/7-8 2x15.4

BV202 0160 230 1-4 2x12 21 5-6/7-8 2x20.6

BV202 0169 400V 1-4 2x6V 29 5-6/7-8 2x8,8V

BV202 0172 400V 1-4 2x9V 19 5-6/7-8 2x13,1V

BV202 0173 400V 1-4 2x12V 15 5-6/7-8 2x17,3V

Yellow field are normaly in stock

Part No

Primary Secondary

www.flexitron.se 10/63

Page 11: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Primary: 12 - 440V~ ±10% 50-60Hz

Secondary: 6 - 24V~, ±5%

Power: 0.5VA to 0.7VA

Temperature class: ta70/F or ta40/F

Isolation: 4kV/10mm/classII

Standard: EN 61558

Approvals: ENEC (Europe)

UL/CSA (USA, Canada)

Overload protection: Built in

Conditionally short circuit proof.

Test: 100% (all individuals)

Weight: 44 g

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI301 2784 24V 1-5 10V 50 7-9 14,9V

EI301 2343 24V 1-5 24V 20 7-9 35,5V

EI301 2785 42V 1-5 10V 50 7-9 14,9V

EI301 2497 42V 1-5 24V 20 7-9 35,5V

EI301 2786 110V 1-5 10V 15 7-9 14,9V

EI301 2300 110V 1-5 12V 42 7-9 18V

EI301 2721 110V 1-5 15V 33 7-9 22,8V

EI301 2334 110V 1-5 24V 20 7-9 35,5V

EI301 2841 115V 1-5 12V 42 7-9 18V

EI301 2439 120V 1-5 24V 20 7-9 35,5V

EI301 3005 230V 1-5 6V 83 7-9 10,2V

EI301 3017 230V 1-5 7,5V 67 7-9 12,2V

EI301 2911 230V 1-5 9V 56 7-9 14,7V

EI301 2783 230V 1-5 10V 50 7-9 14,9V

EI301 2824 230V 1-5 12V 42 7-9 18V

EI301 2845 230V 1-5 15V 33 7-9 22,8V

EI301 2967 230V 1-5 18V 28 7-9 26,5V

EI301 3020 230V 1-5 21V 24 7-9 33,1V

Single secondary voltage 0.50VA ta70/F

SERIES EI301 - 0,5VA-0,7VA

Short circuit proof vacuumed casted safety PCB transformer. With single or dual secondary

windings. If there are two secondary windings they can be both serial and parallel connected.

2*115 V on the primary side on request.

Primary Secondary

Part No

1 2 3 4 5

10 9 8 7 6

1 2 3 4 5

10 9 8 7 6

20,0EI301

Prim

Sec

1 2 3 4 5

10 9 8 7 6

4x5,0

32,5

27,5

15,2

Single secondary

winding

Dual secondary

windings

Bottom view

equipped pins

Soldering pin

0,6x0,8x5

[mm]

www.flexitron.se 11/63

Page 12: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Single secondary voltage 0.50VA ta70/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI301 2787 240V 1-5 10V 50 7-9 14,9V

EI301 2215 240V 1-5 12V 42 7-9 18V

EI301 2256 240V 1-5 24V 20 7-9 35,5V

EI301 2732 380V 1-5 10V 50 7-9 14,9V

EI301 2674 380V 1-5 12V 42 7-9 18V

EI301 2114 380V 1-5 24V 20 7-9 35,5V

EI301 2539 440V 1-5 24V 20 7-9 35,5V

Single secondary voltage 0.70VA ta70/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI301 2713 110V 1-5 12V 50 7-9 19,4V

EI301 2850 115V 1-5 10V 60 7-9 16,1V

EI301 2503 120V 1-5 12V 50 7-9 19,4V

EI301 3582 230V 1-5 6V 117 7-9 10,3V

EI301 3584 230V 1-5 7,5V 94 7-9 12,7V

EI301 3586 230V 1-5 9V 78 7-9 14,6V

EI301 3588 230V 1-5 12V 58 7-9 19,5V

EI301 3590 230V 1-5 15V 47 7-9 24,5V

EI301 3592 230V 1-5 18V 39 7-9 28,3V

EI301 3593 230V 1-5 21V 33 7-9 32,9V

EI301 3594 230V 1-5 24V 29 7-9 37,8

Singel secondary voltage 0.65VA ta70/F short-circuit-proof with thermo-fuse

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI301 7002 230V 1-5 1x6 108 7–9 1x10.5

EI301 7004 230V 1-5 1x7.5 87 7–9 1x13.0

EI301 7006 230V 1-5 1x9 72 7–9 1x15.4

EI301 7008 230V 1-5 1x12 54 7–9 1x20.4

EI301 7010 230V 1-5 1x15 43 7–9 1x24.9

EI301 7012 230V 1-5 1x18 36 7–9 1x30.1

EI301 7013 230V 1-5 1x21 31 7–9 1x35.1

EI301 7014 230V 1-5 1x24 27 7–9 1x40.0

Secondary

Part No

Primary

Primary

Part No

Secondary

Part No

Primary Secondary

www.flexitron.se 12/63

Page 13: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Dual secondary voltage 0.70VA ta70/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI301 3583 230V 1-5 2x6V 58 6-7/9-10 2x10,5V

EI301 3585 230V 1-5 2x7,5V 47 6-7/9-10 2x12,7V

EI301 3587 230V 1-5 2x9V 39 6-7/9-10 2x14,6V

EI301 3589 230V 1-5 2x12V 29 6-7/9-10 2x19,5V

EI301 3591 230V 1-5 2x15V 23 6-7/9-10 2x24,5V

Singel secondary voltage 0.65VA ta70/F short-circuit-proof with thermo-fuse

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI301 7003 230V 1-5 2x6 54 6–7/9–10 2x10.5

EI301 7005 230V 1-5 2x7.5 43 6–7/9–10 2x13.0

EI301 7007 230V 1-5 2x9 36 6–7/9–10 2x15.4

EI301 7009 230V 1-5 2x12 27 6–7/9–10 2x20.4

EI301 7011 230V 1-5 2x15 21 6–7/9–10 2x24.9

Yellow field are normaly in stock

Part No

SecondaryPrimary

Part No

Primary Secondary

www.flexitron.se 13/63

Page 14: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Primary: 12 - 440V~ ±10% 50-60Hz

Secondary: 6 - 24V~, ±5%

Power: 1.5VA or 1.8VA

Temperature class: ta70/F or ta40/F

Isolation: 4kV/10mm/classII

Standard: EN 61558

Approvals: ENEC (Europe)

UL/CSA (USA, Canada)

Overload protection: Built in

Conditionally short circuit proof.

Test: 100% (all individuals)

Weight: 70 g

Single secondary voltage 1.50VA ta70/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI302 2020 230 1–5 1x6 250 7–9 1x8.2

EI302 3058 230 1–5 1x7.5 200 7–9 1x10.5

EI302 2021 230 1–5 1x9 166 7–9 1x12.1

EI302 2022 230 1–5 1x12 125 7–9 1x16.6

EI302 2023 230 1–5 1x15 100 7–9 1x20.6

EI302 2024 230 1–5 1x18 83 7–9 1x24.5

EI302 3059 230 1–5 1x21 71 7–9 1x28.6

EI302 2989 230 1–5 1x24 62 7–9 1x33.5

Single secondary voltage 1.80VA ta40/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI302 2000 230 1–5 1x6 300 7–9 1x8.8

EI302 3021 230 1–5 1x7.5 240 7–9 1x10.7

EI302 2001 230 1–5 1x9 200 7–9 1x12.6

EI302 2002 230 1–5 1x12 150 7–9 1x16.9

EI302 2003 230 1–5 1x15 120 7–9 1x21.1

EI302 2004 230 1–5 1x18 100 7–9 1x25.4

EI302 3022 230 1–5 1x21 86 7–9 1x30.4

EI302 2990 230 1–5 1x24 75 7–9 1x34.5

Part No

Primary Secondary

Part No

Primary Secondary

Short circuit proof vacuumed casted safety PCB transformer. With single or dual secondary

windings. If there are two secondary windings they can be both serial and parallel connected.

2*115 V on the primary side on request.

SERIES EI302 - 1,5VA/1,8VA

1 2 3 4 5

10 9 8 7 6

1 2 3 4 5

10 9 8 7 6

20,0EI302

Prim 1 2 3 4 5

10 9 8 7 6

4x5,0

32,5

27,5

21,8

Sec

Single secondarywinding

Dual secondarywindings

[mm]

Bottom view

equipped pins

Soldering pin

0,6x0,8x5

www.flexitron.se 14/63

Page 15: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Single secondary voltage 1.8VA ta70/F short-circuit-proof with thermo-fuse

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI302 7015 230 1–5 1x6 300 7–9 1x9.8

EI302 7017 230 1–5 1x7.5 240 7–9 1x12.2

EI302 7019 230 1–5 1x9 200 7–9 1x14.6

EI302 7021 230 1–5 1x12 150 7–9 1x19.4

EI302 7023 230 1–5 1x15 120 7–9 1x24.3

EI302 7025 230 1–5 1x18 100 7–9 1x29.2

EI302 7026 230 1–5 1x21 86 7–9 1x34.1

EI302 7027 230 1–5 1x24 75 7–9 1x38.8

Dual secondary voltage 1.5VA ta70/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI302 2025 230 1–5 2x6 125 6–7/9-10 2x8.7

EI302 3561 230 1–5 2x7.5 100 6–7/9-10 2x10.5

EI302 2026 230 1–5 2x9 83 6–7/9-10 2x12.4

EI302 2027 230 1–5 2x12 62 6–7/9-10 2x16.6

EI302 2028 230 1–5 2x15 50 6–7/9-10 2x20.4

Dual secondary voltage 1.8VA ta40/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI302 2005 230 1–5 2x6 150 6–7/9-10 2x8.8

EI302 3562 230 1–5 2x7.5 120 6–7/9-10 2x11.0

EI302 2006 230 1–5 2x9 100 6–7/9-10 2x13.0

EI302 2007 230 1–5 2x12 75 6–7/9-10 2x18.3

EI302 2008 230 1–5 2x15 60 6–7/9-10 2x21.8

Dual secondary voltage 1.8VA ta70/F short-circuit-proof with thermo-fuse

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI302 7016 230 1–5 2x6 150 6–7/9-10 2x10.6

EI302 7018 230 1–5 2x7.5 120 6–7/9-10 2x13.4

EI302 7020 230 1–5 2x9 100 6–7/9-10 2x15.9

EI302 7022 230 1–5 2x12 75 6–7/9-10 2x20.9

EI302 7024 230 1–5 2x15 60 6–7/9-10 2x24.8

Yellow field are normaly in stock

Primary Secondary

Part No

Primary Secondary

Part No

Primary Secondary

Part No

Primary Secondary

Part No

www.flexitron.se 15/63

Page 16: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Primary: 12 - 440V~ ±10% 50-60Hz

Secondary: 6 - 24V~, ±5%

Power: 1.8VA

Temperature class: ta70/F or ta40/F

Isolation: 4kV/10mm/classII

Standard: EN 61558

Approvals: ENEC (Europe)

UL/CSA (USA, Canada)

Overload protection: Built in

Conditionally short circuit proof.

Test: 100% (all individuals)

Weight: 76 g

Single secondary voltage 1,8VA ta70/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI307 3842 230 1-5 1x6 300 7-9 1x9.7

EI307 3844 230 1-5 1x7.5 240 7-9 1x12.7

EI307 3846 230 1-5 1x9 200 7-9 1x14.5

EI307 3801 230 1-5 1x12 150 7-9 1x18.7

EI307 3849 230 1-5 1x15 120 7-9 1x24.5

EI307 3851 230 1-5 1x18 100 7-9 1x28.4

EI307 3852 230 1-5 1x21 86 7-9 1x33.4

EI307 3853 230 1-5 1x24 75 7-9 1x37.9

Single secondary voltage 1,8VA ta70/F short-circuit-proof with thermo-fuse

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI307 7079 230 1-5 1x6 300 7–9 1x9.8

EI307 7081 230 1-5 1x7.5 240 7–9 1x12.9

EI307 7083 230 1-5 1x9 200 7–9 1x14.7

EI307 7085 230 1-5 1x12 150 7–9 1x19.4

EI307 7087 230 1-5 1x15 120 7–9 1x24.1

EI307 7089 230 1-5 1x18 100 7–9 1x28.9

EI307 7090 230 1-5 1x21 86 7–9 1x34.8

EI307 7091 230 1-5 1x24 75 7–9 1x38.5

SERIES EI307 - 1,8VA

Short circuit proof vacuumed casted safety PCB transformer. With single or dual secondary

windings. If there are two secondary windings they can be both serial and parallel connected.

2*115 V on the primary side on request.

Part No

SecondaryPrimary

Part No

SecondaryPrimary

1 2 3 4 5

10 9 8 7 6

1 2 3 4 5

10 9 8 7 6

27,520,0EI307

Prim 1 2 3 4 5

10 9 8 7 6

4x5,0

32,5 22,1

Sec

Single secondary

winding

Dual secondary

windings[mm]

Bottom view

equipped pinsSoldering pin

0,6x0,8x5

www.flexitron.se 16/63

Page 17: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Dual secondary voltage 1,8VA ta70/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI307 3843 230 1-5 2x6 2x150 6-7/9-10 2x9.4

EI307 3845 230 1-5 2x7.5 2x120 6-7/9-10 2x12.4

EI307 3847 230 1-5 2x9 2x100 6-7/9-10 2x14.3

EI307 3848 230 1-5 2x12 2x75 6-7/9-10 2x18.9

EI307 3850 230 1-5 2x15 2x60 6-7/9-10 2x24.5

Dual secondary voltage 1,8VA ta70/F short-circuit-proof with thermo-fuse

Voltage Pins VoltageMax current

[mA]Pins

No load

voltageEI307 7080 230 1-5 2x6 150 6–7/9–10 2x9.8

EI307 7082 230 1-5 2x7.5 120 6–7/9–10 2x13.2

EI307 7084 230 1-5 2x9 100 6–7/9–10 2x15.2

EI307 7086 230 1-5 2x12 75 6–7/9–10 2x20.1

EI307 7088 230 1-5 2x15 60 6–7/9–10 2x24.1

Yellow field are normaly in stock

Part NoPrimary Secondary

Part No

Primary Secondary

www.flexitron.se 17/63

Page 18: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Primary: 12 - 440V~ ±10% 50-60Hz

Secondary: 6 - 24V~, ±5%

Power: 1.9VA or 2.3VA

Temperature class: ta70/F or ta40/F

Isolation: 4kV/10mm/classII

Standard: EN 61558

Approvals: ENEC (Europe)

UL/CSA (USA, Canada)

Overload protection: Built in

Conditionally short circuit proof.

Test: 100% (all individuals)

Weight: 81 g

Single secondary voltage 1.9VA ta70/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI303 2693 24V 1-5 18V 105 7-9 25,8V

EI303 2669 110V 1-5 12V 158 7-9 17,2V

EI303 2982 110V 1-5 18V 105 7-9 25,8V

EI303 2744 110V 1-5 24V 79 7-9 35,5V

EI303 2943 115V 1-5 9V 211 7-9 12,9V

EI303 2897 115V 1-5 12V 158 7-9 17,2V

EI303 2739 127V 1-5 24V 79 7-9 35,5V

Single secondary voltage 1.9VA ta70/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI303 2030 230 1–5 1x6 316 7–9 1x8.6

EI303 3060 230 1–5 1x7.5 253 7–9 1x11.0

EI303 2031 230 1–5 1x9 211 7–9 1x12.9

EI303 2032 230 1–5 1x12 158 7–9 1x17.2

EI303 2033 230 1–5 1x15 126 7–9 1x21.5

EI303 2034 230 1–5 1x18 105 7–9 1x25.8

EI303 3013 230 1–5 1x21 90 7–9 1x30.0

EI303 2100 230 1–5 1x24 79 7–9 1x35.5

Part No

SecondaryPrimary

SERIES EI303 - 1,9VA/2,3VA

Short circuit proof vacuumed casted safety PCB transformer. With single or dual secondary

windings. If there are two secondary windings they can be both serial and parallel connected.

2*115 V on the primary side on request.

Secondary

Part No

Primary

1 2 3 4 5

10 9 8 7 6

1 2 3 4 5

10 9 8 7 6

27,520,0EI303

Prim 1 2 3 4 5

10 9 8 7 6

4x5,0

32,5 24,0

Sec

Single secondary

winding

Dual secondary

windings[mm]

Bottom viewequipped pins

Soldering pin 0,6x0,8x5

www.flexitron.se 18/63

Page 19: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Single secondary voltage 2.3VA ta40/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI303 2010 230 1–5 1x6 383 7–9 1x8.5

EI303 3611 230 1–5 1x7.5 307 7–9 1x11.4

EI303 2011 230 1–5 1x9 255 7–9 1x12.9

EI303 2012 230 1–5 1x12 191 7–9 1x17.4

EI303 2013 230 1–5 1x15 153 7–9 1x21.6

EI303 2014 230 1–5 1x18 127 7–9 1x25.8

EI303 3563 230 1–5 1x21 110 7–9 1x30.2

EI303 2991 230 1–5 1x24 96 7–9 1x33.7

Single secondary voltage 2.3VA ta70/F short-circuit-proof with thermo-fuse

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI303 7028 230 1–5 1x6 383 7–9 1x9.4

EI303 7030 230 1–5 1x7.5 306 7–9 1x11.3

EI303 7032 230 1–5 1x9 256 7–9 1x13.8

EI303 7034 230 1–5 1x12 191 7–9 1x17.4

EI303 7036 230 1–5 1x15 153 7–9 1x22.3

EI303 7038 230 1–5 1x18 128 7–9 1x26.4

EI303 7039 230 1–5 1x21 110 7–9 1x30.5

EI303 7040 230 1–5 1x24 96 7–9 1x34.0

Dual secondary voltage 1.9VA ta70/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI303 2690 115V 1-5 2x7,5V 126 6-7/9-10 2x11,7V

EI303 2035 230 1–5 2x6 158 6–7/9–10 2x9.3

EI303 2095 230 1–5 2x7.5 126 6–7/9–10 2x12.3

EI303 2036 230 1–5 2x9 105 6–7/9–10 2x13.9

EI303 2037 230 1–5 2x12 79 6–7/9–10 2x18.5

EI303 2038 230 1–5 2x15 63 6–7/9–10 2x21.9

EI303 2684 240V 1-5 2x15V 63 6-7/9-10 21,9V

EI303 2535 400V 1-5 2x9V 105 6-7/9-10 2x13,2V

Dual secondary voltage 2.3VA ta40/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI303 2015 230 1–5 2x6 191 6–7/9–10 2x9.4

EI303 3612 230 1–5 2x7.5 153 6–7/9–10 2x12.4

EI303 2016 230 1–5 2x9 127 6–7/9–10 2x14.6

EI303 2017 230 1–5 2x12 95 6–7/9–10 2x18.8

EI303 2018 230 1–5 2x15 76 6–7/9–10 2x23.4

Dual secondary voltage 2.3VA ta70/F short-circuit-proof with thermo-fuse

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI303 7029 230 1–5 2x6 191 6–7/9–10 2x9.7

EI303 7031 230 1–5 2x7.5 153 6–7/9–10 2x12.2

EI303 7033 230 1–5 2x9 128 6–7/9–10 2x14.3

EI303 7035 230 1–5 2x12 96 6–7/9–10 2x19.1

EI303 7037 230 1–5 2x15 76 6–7/9–10 2x23.7

* Non ENEC approval.

Yellow field are normaly in stock

Part No

Primary

Secondary

Part No

Primary

Secondary

Part No

Primary Secondary

Part No

Secondary

Part No

Secondary

Primary

Primary

www.flexitron.se 19/63

Page 20: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Primary: 12 - 440V~ ±10% 50-60Hz

Secondary: 6 - 24V~, ±5%

Power: 2.1VA to 2.6VA

Temperature class: ta70/F or ta40/F

Isolation: 4kV/10mm/classII

Standard: EN 61558

Approvals: ENEC (Europe)

UL/CSA (USA, Canada)

Overload protection: Built in

Conditionally short circuit proof.

Test: 100% (all individuals)

Weight: 99 g

Single secondary voltage 2.1VA ta70/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI304 2952 24V 1-5 18V 117 7-9 30V

EI304 2689 42V 1-5 18V 117 7-9 30V

EI304 2712 42V 1-5 24V 88 7-9 37,3V

EI304 2524 110V 1-5 9V 234 7-9 16V

EI304 2281 110V 1-5 10V 210 7-9 17,4V

EI304 2362 110V 1-5 12V 175 7-9 21,5V

EI304 2820 110V 1-5 15V 140 7-9 26,5V

EI304 2718 110V 1-5 18V 117 7-9 30V

EI304 2803 115V 1-5 10V 210 7-9 17,4V

EI304 2818 115V 1-5 15V 140 7-9 26,5V

EI304 2301 115V 1-5 21V 100 7-9 33,4V

Primary

SERIES EI304 - 2,1VA/2,4VA/2,6VA

Short circuit proof vacuumed casted safety PCB transformer. With single or dual secondary

windings. If there are two secondary windings they can be both serial and parallel connected.

2*115 V on the primary side on request.

Part NoSecondary

1 2 3 4 5

10 9 8 7 6

1 2 3 4 5

10 9 8 7 6

27,520,0EI304

Prim 1 2 3 4 5

10 9 8 7 6

4x5,0

32,5 27,0

Sec

Single secondary

winding

Dual secondary

windings[mm]

Bottom view

equipped pins

Soldering pin

0,6x0,8x5

www.flexitron.se 20/63

Page 21: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Single secondary voltage 2.1VA ta70/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI304 2080 230 1–5 1x6 350 7–9 1x10.5

EI304 2889 230 1–5 1x7.5 280 7–9 1x13.7

EI304 2081 230 1–5 1x9 233 7–9 1x15.8

EI304 2082 230 1–5 1x12 175 7–9 1x21.5

EI304 2083 230 1–5 1x15 140 7–9 1x26.5

EI304 2084 230 1–5 1x18 117 7–9 1x30.0

EI304 2843 230 1–5 1x21 100 7–9 1x33.4

EI304 2868 230 1–5 1x24 88 7–9 1x37.3

EI304 2490 240V 1-5 10V 210 7-9 15,8V

EI304 2899 240V 1-5 12V 175 7-9 21,5V

EI304 2862 240V 1-5 18V 117 7-9 30V

EI304 2345 240V 1-5 21V 100 7-9 33,4V

EI304 2797 240V 1-5 24V 88 7-9 37,3V

EI304 3015 400V 1-5 12V 175 7-9 21,5V

EI304 2735 400V 1-5 21V 100 7-9 33,4V

Single secondary voltage 2.4VA ta70/F short-circuit-proof with thermo-fuse

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI304 7041 230 1–5 1x6 400 7–9 1x10.6

EI304 7043 230 1–5 1x7.5 320 7–9 1x13.2

EI304 7045 230 1–5 1x9 266 7–9 1x16.3

EI304 7047 230 1–5 1x12 200 7–9 1x21.9

EI304 7049 230 1–5 1x15 160 7–9 1x26.8

EI304 7050 230 1–5 1x18 133 7–9 1x32.6

EI304 7051 230 1–5 1x21 114 7–9 1x37.2

EI304 7052 230 1–5 1x24 100 7–9 1x42.3

Single secondary voltage 2.6VA ta40/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI304 2951 24V 1-5 9V 289 7-9 15,9V

EI304 2790 110V 1-5 9V 289 7-9 15,9V

EI304 2430 110V 1-5 12V 217 7-9 21,7V

EI304 2819 110V 1-5 18V 145 7-9 30,9V

EI304 2040 230 1–5 1x6 434 7–9 1x10.4

EI304 3564 230 1–5 1x7.5 346 7–9 1x12.5

EI304 2041 230 1–5 1x9 289 7–9 1x15.9

EI304 2042 230 1–5 1x12 217 7–9 1x21.7

EI304 2043 230 1–5 1x15 174 7–9 1x27.4

EI304 2044 230 1–5 1x18 145 7–9 1x30.9

EI304 2995 230 1–5 1x21 123 7–9 1x32.1

EI304 2992 230 1–5 1x24 108 7–9 1x41.7

EI304 2443 400V 1-5 24V 108 7-9 41,7V

Part NoSecondaryPrimary

Primary

Part NoPrimary Secondary

Part NoSecondary

www.flexitron.se 21/63

Page 22: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Dual secondary voltage 2.1VA ta70/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI304 2498 24V 1-5 2x15V 70 6-7/9-10 2x26,5V

EI304 2476 24V 1-5 2x18V 58 6-7/9-10 2x29,8V

EI304 2366 42V 1-5 2x12V 88 6-7/9-10 2x21,5V

EI304 2367 110V 1-5 2x12V 88 6-7/9-10 2x21,5V

EI304 2423 110V 1-5 2x15V 70 6-7/9-10 2x26,5V

EI304 2825 110V 1-5 2x18V 58 6-7/9-10 2x29,8V

EI304 2085 230 1–5 2x6 175 6–7/9–10 2x11.2

EI304 2773 230 1–5 2x7.5 140 6–7/9–10 2x13.9

EI304 2086 230 1–5 2x9 117 6–7/9–10 2x16.0

EI304 2087 230 1–5 2x12 88 6–7/9–10 2x22.0

EI304 2424 240V 1-5 2x15V 70 6-7/9-10 2x26,5V

EI304 2556 240V 1-5 2x18V 58 6-7/9-10 2x29,8V

EI304 2711 400V 1-5 2x18V 58 6-7/9-10 2x29,8V

Dual secondary voltage 2.4VA ta70/F short-circuit-proof with thermo-fuse

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI304 7042 230 1–5 2x6 200 6–7/9–10 2x10.1

EI304 7044 230 1–5 2x7.5 160 6–7/9–10 2x13.2

EI304 7046 230 1–5 2x9 133 6–7/9–10 2x16.8

EI304 7048 230 1–5 2x12 100 6–7/9–10 2x21.9

EI304 7095 230 1–5 2x15 80 6–7/9–10 2x24.7

Dual secondary voltage 2.6VA ta40/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI304 2835 110V 1-5 2x6V 217 6-7/9-10 2x10,4V

EI304 2045 230 1–5 2x6 217 6–7/9–10 2x10.8

EI304 2840 230 1–5 2x7.5 173 6–7/9–10 2x12.5

EI304 2046 230 1–5 2x9 145 6–7/9–10 2x16.2

EI304 2047 230 1–5 2x12 108 6–7/9–10 2x22.4

EI304 2798 240V 1-5 2x7,5V 173 6-7/9-10 2x12,5V

* Non ENEC approval.

Yellow field are normally in stock

Part NoSecondary

Part NoSecondary

Primary

Part NoPrimary Secondary

Primary

www.flexitron.se 22/63

Page 23: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Primary: 12 - 440V~ ±10% 50-60Hz

Secondary: 6 - 24V~, ±5%

Power: 2,3VA to 3,0VA

Temperature class: ta70/F or ta40/F

Isolation: 4kV/10mm/classII

Standard: EN 61558

Approvals: ENEC (Europe)

UL/CSA (USA, Canada)

Overload protection: Built in

Conditionally short circuit proof.

Test: 100% (all individuals)

Weight: 111 g

Single secondary voltage 2.3VA ta70/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI305 2736 24V 1-5 12V 192 7-9 21,4V

EI305 2307 24V 1-5 15V 153 7-9 28,2V

EI305 2310 24V 1-5 24V 96 7-9 43,5V

EI305 2555 42V 1-5 24V 96 7-9 43,5V

EI305 2738 100V 1-5 15V 153 7-9 28,2V

EI305 2884 110V 1-5 10V 230 7-9 18,6V

EI305 2710 110V 1-5 12V 192 7-9 21,4V

EI305 2308 110V 1-5 15V 153 7-9 28,2V

EI305 2671 110V 1-5 18V 128 7-9 32,4V

EI305 2311 110V 1-5 24V 96 7-9 43,5V

EI305 2544 110V 1-5 9V 255 7-9 17,6V

EI305 2102 115V 1-5 24V 96 7-9 43,5V

EI305 2471 127V 1-5 18V 128 7-9 32,4V

SERIES EI305 - 2,3VA-3,0VA

Part No

Short circuit proof vacuumed casted safety PCB transformer. With single or dual secondary

windings. If there are two secondary windings they can be both serial and parallel connected.

2*115 V on the primary side on request.

Primary Secondary

1 2 3 4 5

10 9 8 7 6

1 2 3 4 5

10 9 8 7 6

27,520,0EI305

Prim 1 2 3 4 5

10 9 8 7 6

4x5,0

32,5 29,8

Sec

Single secondary

winding

Dual secondary

windings[mm]

Bottom viewequipped pins

Soldering pin 0,6x0,8x5

www.flexitron.se 23/63

Page 24: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Single secondary voltage 2.3VA ta70/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI305 2878 230 1–5 1x6 383 7–9 1x11.6

EI305 2893 230 1–5 1x7.5 305 7–9 1x15.2

EI305 2879 230 1–5 1x9 255 7–9 1x17.6

EI305 2800 230 1–5 1x12 192 7–9 1x21.4

EI305 2805 230 1–5 1x15 153 7–9 1x28.2

EI305 2851 230 1–5 1x18 128 7–9 1x32.4

EI305 2772 230 1–5 1x21 110 7–9 1x38.4

EI305 2874 230 1–5 1x24 96 7–9 1x45.4

EI305 2672 240V 1-5 12V 192 7-9 21,4V

EI305 2309 240V 1-5 15V 153 7-9 28,2V

EI305 2324 240V 1-5 18V 128 7-9 32,4V

EI305 2312 240V 1-5 24V 96 7-9 43,5V

EI305 2814 380V 1-5 18V 128 7-9 32,4V

EI305 2100 500V 1-5 18V 128 7-9 32,4V

Single secondary voltage 2.7VA ta70/F short-circuit-proof with thermo-fuse

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI305 7053 230 1–5 1x6 450 7–9 1x10.9

EI305 7055 230 1–5 1x7.5 360 7–9 1x13.7

EI305 7057 230 1–5 1x9 300 7–9 1x16.2

EI305 7059 230 1–5 1x12 225 7–9 1x20.7

EI305 7061 230 1–5 1x15 180 7–9 1x26.6

EI305 7063 230 1–5 1x18 150 7–9 1x33.0

EI305 7064 230 1–5 1x21 128 7–9 1x37.6

EI305 7065 230 1–5 1x24 112 7–9 1x42.9

Single secondary voltage 3.0VA ta40/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI305 2753 24V 1-5 18V 167 7-9 32,5V

EI305 2715 110V 1-5 6V 500 7-9 10,7V

EI305 2749 110V 1-5 8V 375 7-9 15,4V

EI305 2518 110V 1-5 10V 300 7-9 16,9V

EI305 2965 110V 1-5 12V 250 7-9 20,4V

EI305 2280 110V 1-5 15V 200 7-9 26,7V

EI305 2745 110V 1-5 18V 167 7-9 32,5V

EI305 2961 115V 1-5 9V 334 7-9 17,3V

EI305 2050 230 1–5 1x6 500 7–9 1x10.7

EI305 3565 230 1–5 1x7.5 400 7–9 1x13.7

EI305 2051 230 1–5 1x9 334 7–9 1x17.3

EI305 2052 230 1–5 1x12 250 7–9 1x20.4

EI305 2053 230 1–5 1x15 200 7–9 1x26.7

EI305 2054 230 1–5 1x18 167 7–9 1x32.5

EI305 2188 230 1–5 1x21 143 7–9 1x35.7

EI305 2993 230 1–5 1x24 125 7–9 1x42.0

Primary Secondary

Part No

Secondary

Part No

Primary

Primary

Secondary

Part No

www.flexitron.se 24/63

Page 25: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Single secondary voltage 3.0VA ta40/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI305 2695 240V 1-5 8V 375 7-9 15,4V

EI305 2755 240V 1-5 10V 300 7-9 16,9V

EI305 2554 240V 1-5 12V 250 7-9 20,4V

EI305 2752 240V 1-5 15V 200 7-9 26,7V

EI305 2663 400V 1-5 12V 250 7-9 20,4V

EI305 2665 400V 1-5 24V 125 7-9 42V

Dual secondary voltage 2.3VA ta70/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI305 2682 110V 1-5 2x7,5V 153 6-7/9-10 2x13,8V

EI305 2494 110V 1-5 2x12V 96 6-7/9-10 2x21,8V

EI305 2882 230 1–5 2x6 192 6–7/9–10 2x11.1

EI305 2894 230 1–5 2x7.5 153 6–7/9–10 2x13.0

EI305 2866 230 1–5 2x9 127 6–7/9–10 2x16.1

EI305 2847 230 1–5 2x12 96 6–7/9–10 2x21.8

EI305 2844 230 1–5 2x15 76 6–7/9–10 2x24.1

Dual secondary voltage 2.7VA ta70/F short-circuit-proof with thermo-fuse

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI305 7054 230 1–5 2x6 225 6–7/9–10 2x10.3

EI305 7056 230 1–5 2x7.5 180 6–7/9–10 2x13.4

EI305 7058 230 1–5 2x9 150 6–7/9–10 2x16.8

EI305 7060 230 1–5 2x12 112 6–7/9–10 2x22.1

EI305 7062 230 1–5 2x15 90 6–7/9–10 2x24.6

Dual secondary voltage 3.0VA ta40/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI305 2678 110V 1-5 2x7,5V 200 6-7/9-10 2x13,7V

EI305 2527 110V 1-5 2x15V 100 6-7/9-10 2x28V

EI305 2055 230 1–5 2x6 250 6–7/9–10 2x10.7

EI305 2922 230 1–5 2x7.5 200 6–7/9–10 2x13.7

EI305 2056 230 1–5 2x9 167 6–7/9–10 2x15.9

EI305 2057 230 1–5 2x12 125 6–7/9–10 2x20.3

EI305 2099 400V 1-5 2x12V 125 6-7/9-10 2x20,9V

EI305 2743 440V 1-5 2x12V 125 6-7/9-10 2x20,9V

* Non ENEC approval.

Yellow field are normally in stock

Part No

Primary Secondary

Part No

Part No

Secondary

Secondary

Secondary

Part No

Primary

Primary

Primary

www.flexitron.se 25/63

Page 26: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Primary: 12 - 440V~ ±10% 50-60Hz

Secondary: 6 - 24V~, ±5%

Power: 3,0VA to 3,6VA

Temperature class: ta70/F or ta40/F

Isolation: 4kV/10mm/classII

Standard: EN 61558

Approvals: ENEC (Europe)

UL/CSA (USA, Canada)

Overload protection: Built in

Conditionally short circuit proof.

Test: 100% (all individuals)

Weight: 135 g

Single secondary voltage 3,0VA ta70/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI306 3359 230 1–5 1x6 500 7–9 1x10.5

EI306 3361 230 1–5 1x7.5 400 7–9 1x12.7

EI306 3363 230 1–5 1x9 333 7–9 1x15.9

EI306 3365 230 1–5 1x12 250 7–9 1x20.3

EI306 3367 230 1–5 1x15 200 7–9 1x23.8

EI306 3369 230 1–5 1x18 167 7–9 1x29.2

EI306 3371 230 1–5 1x21 143 7–9 1x34.3

EI306 3372 230 1–5 1x24 125 7–9 1x38.4

Single secondary voltage 3,4VA ta70/F short-circuit-proof with thermo-fuse

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI306 7066 230 1–5 1x6 566 7–9 1x11.0

EI306 7068 230 1–5 1x7.5 453 7–9 1x13.6

EI306 7070 230 1–5 1x9 378 7–9 1x16.0

EI306 7072 230 1–5 1x12 283 7–9 1x21.0

EI306 7074 230 1–5 1x15 226 7–9 1x26.0

EI306 7076 230 1–5 1x18 189 7–9 1x32.2

EI306 7077 230 1–5 1x21 162 7–9 1x37.5

EI306 7078 230 1–5 1x24 141 7–9 1x43.1

Part No

Primary Secondary

SERIES EI306 - 3,0VA-3,6VA

Short circuit proof vacuumed casted safety PCB transformer. With single or dual secondary

windings. If there are two secondary windings they can be both serial and parallel connected.

2*115 V on the primary side on request.

Part No

SecondaryPrimary

1 2 3 4 5

10 9 8 7 6

1 2 3 4 5

10 9 8 7 6

27,520,0EI306

Prim 1 2 3 4 5

10 9 8 7 6

4x5,0

32,5 33,8

Sec

Single secondary

winding

Dual secondary

windings[mm]

Bottom view

equipped pins

Soldering pin

0,6x0,8x5

www.flexitron.se 26/63

Page 27: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Single secondary voltage 3.6VA ta40/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI306 3595 230 1–5 1x6 600 7–9 1x10.8

EI306 3597 230 1–5 1x7.5 480 7–9 1x13.3

EI306 3599 230 1–5 1x9 400 7–9 1x15.7

EI306 3601 230 1–5 1x12 300 7–9 1x21.0

EI306 3603 230 1–5 1x15 240 7–9 1x24.5

EI306 3605 230 1–5 1x18 200 7–9 1x31.4

EI306 3606 230 1–5 1x21 171 7–9 1x35.5

EI306 3607 230 1–5 1x24 150 7–9 1x42.0

Dual secondary voltage 3,0VA ta70/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI306 3360 230 1–5 2x6 250 6–7/9–10 2x10.5

EI306 3362 230 1–5 2x7.5 200 6–7/9–10 2x12.7

EI306 3364 230 1–5 2x9 167 6–7/9–10 2x15.9

EI306 3366 230 1–5 2x12 125 6–7/9–10 2x20.3

EI306 3368 230 1–5 2x15 100 6–7/9–10 2x23.8

Dual secondary voltage 3,4VA ta70/F short-circuit-proof with thermo-fuse

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI306 7067 230 1–5 2x6 283 6–7/9–10 2x10.7

EI306 7069 230 1–5 2x7.5 226 6–7/9–10 2x12.4

EI306 7071 230 1–5 2x9 189 6–7/9–10 2x16.8

EI306 7073 230 1–5 2x12 141 6–7/9–10 2x22.1

EI306 7075 230 1–5 2x15 113 6–7/9–10 2x24.6

Dual secondary voltage 3.6VA ta40/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI306 3596 230 1–5 2x6 300 6–7/9–10 2x10.8

EI306 3598 230 1–5 2x7.5 240 6–7/9–10 2x13.3

EI306 3600 230 1–5 2x9 200 6–7/9–10 2x15.7

EI306 3602 230 1–5 2x12 150 6–7/9–10 2x21.0

EI306 3604 230 1–5 2x15 120 6–7/9–10 2x24.5

Yellow fields are normally in stock

Part No

Secondary

Part No

Part No

Primary

Primary

Primary Secondary

Secondary

Part No

Primary Secondary

www.flexitron.se 27/63

Page 28: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Primary: Max 500V~

Secondary: Max 250V~

Power: 2,5VA

Temperature class: ta70/B

Isolation:

Standard: EN 61558

Approvals: In application.

Overload protection:

Test:

Weight: 100 g

Vacuum casted safety PCB transformer. Customer specific design. Symmetric and

asymmetric bobbins and pins are possible. Provide with both internal and external overload

protection.

SERIES EI381 - 2,5VA

1-2 bobbins.

1-2 bobbins.

Standard types not define. Manufacture on order, according to customer specification.

4kV/10mm/classII

100% (All individuals)

External or internal.

According to requirements.

41,0

1 2 3 4 5

10 9 8 7 6

4x5,0

EI381

22,1

35,1

Prim1 2 3 4 5

10 9 8 7 6

1 2 3 4 5

10 9 8 7 6

25,0

Sec

Single secondary

winding

Dual secondary

windings

Bottom viewequipped pins

Soldering pin

0,6x0,8x5

[mm]

www.flexitron.se 28/63

Page 29: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Primary: 230V~ ±10% 50-60Hz

Different voltage on request.

Max primary current: 42 mA at full load.

Secondary: 6 - 24V~, ±5%

Power: 4,5VA

Temperature class: ta70/B

Isolation: 4kV/10mm/classII

Standard: EN 61558

Approvals: ENEC (Europe)

UL/CSA (USA, Canada)

Overload protection:

Test:

Weight: 150 g

Single secondary voltage 4.50VA ta70/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI382 1185 230 1–5 1x6 750 7–9 1x9.7

EI382 1187 230 1–5 1x7.5 600 7–9 1x10.6

EI382 1189 230 1–5 1x9 500 7–9 1x13.0

EI382 1191 230 1–5 1x12 375 7–9 1x17.0

EI382 1193 230 1–5 1x15 300 7–9 1x20.8

EI382 1195 230 1–5 1x18 250 7–9 1x24.4

EI382 1197 230 1–5 1x24 187 7–9 1x33.5

Dual secondary voltage 4.50VA ta40/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI382 1186 230 1–5 2x6 375 6–7/9–10 2x9.2

EI382 1188 230 1–5 2x7.5 300 6–7/9–10 2x10.9

EI382 1190 230 1–5 2x9 250 6–7/9–10 2x13.0

EI382 1192 230 1–5 2x12 187 6–7/9–10 2x18.4

EI382 1194 230 1–5 2x15 150 6–7/9–10 2x21.2

EI382 1196 230 1–5 2x18 125 6–7/9–10 2x24.9

Yellow field are normaly in stock

Part NoPrimary Secondary

Vacuum casted safety PCB transformer, with one or two secondary windings. The dual

secondary windings can be ether serial or parallel connected. Use a PTC-resistor as overload

protection. 2*115 V on the primary side on request.

External fuse or PTC

(not included)

SERIES EI382 - 4,5VA

100% (All individuals)

Part NoPrimary Secondary

41,0

1 2 3 4 5

10 9 8 7 6

4x5,0

EI382

28,1

35,1

Prim1 2 3 4 5

10 9 8 7 6

1 2 3 4 5

10 9 8 7 6

25,0

Sec

Single secondary

winding

Dual secondary

windings

Bottom view

equipped pins

Soldering pin

0,6x0,8x5

[mm]

www.flexitron.se 29/63

Page 30: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Primary:

Secondary:

Power: 6VA

Temperature class: ta70/B

Isolation:

Standard:

Approvals:

Overload protection:

Test:

Weight: 250g

Standard types not define. Manufacture on order, according to customer specification.

Max 250V~

In application.

External or internal.

According to requirements.

100% (All individuals)

1-2 bobbins.

4kV/10mm/classII

EN 61558

Vacuum casted safety PCB transformer. Customer specific design. Symmetric and

asymmetric bobbins and pins are possible. Provide with both internal and external overload

protection.

SERIES EI383 - 6VA

Max 500V~

1-2 bobbins.

41,0

1 2 3 4 5

10 9 8 7 6

4x5,0

EI382

30,8

35,1

Prim1 2 3 4 5

10 9 8 7 6

1 2 3 4 5

10 9 8 7 6

25,0

Sec

Single secondary

winding

Dual secondarywindings

Bottom view

equipped pins

Soldering pin

0,6x0,8x5

[mm]

www.flexitron.se 30/63

Page 31: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Primary: Max 500V~

Secondary: Max 250V~

Power: 3VA

Temperature class: ta70/B

Isolation:

Standard: EN 61558

Approvals: In application.

Overload protection:

Test:

Weight: 120 g

Standard types not define. Manufacture on order, according to customer specification.

Vacuum casted safety PCB transformer. Customer specific design. Symmetric and asymmetric

bobbins and pins are possible. Provide with both internal and external overload protection.

100% (All individuals)

Series EI421 - 3VA

1-2 bobbins.

1-2 bobbins.

4kV/10mm/classII

External or internal.

2 3 4 5

10 9 8 7

6

1112

55,0

64,0

EI421 25,0

1

5x5,0

43,8

Prim

36,8

26,2

2 3 4 5

109 8 7

6

1112

12 3 4 5

109 8 7

6

1112

1

Sec

Mounting hole

Dia. 4,2Single secondary

winding

Dual secondary

windings

Bottom viewequipped pins

Soldering pin 0,6x0,8x5

[mm]

www.flexitron.se 31/63

Page 32: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Primary: 230V~ ±10% 50-60Hz

Different voltage on request

Max primary current: 48 mA at full load

Secondary: 6 - 24V~, ±5%

Power: 6VA

Temperature class: ta70/B

Isolation: 4kV/10mm/classII

Standard: EN 61558

Approvals: ENEC (Europe)

UL/CSA (USA, Canada)

Overload protection:

Test: 100% (all individuals)

Weight: 200 g

Single secondary voltage 6VA ta70/B

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI422 1218 230 1–5 1x6 1000 7–9 1x8.7

EI422 1220 230 1–5 1x7.5 800 7–9 1x10.9

EI422 1222 230 1–5 1x9 667 7–9 1x13.0

EI422 1224 230 1–5 1x12 500 7–9 1x16.7

EI422 1226 230 1–5 1x15 400 7–9 1x20.2

EI422 1228 230 1–5 1x18 334 7–9 1x24.6

EI422 1230 230 1–5 1x24 250 7–9 1x30.8

Dual secondary voltage 6VA ta70/B

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI422 1219 230 1–5 2x6 500 6–7/9–10 2x8.7

EI422 1221 230 1–5 2x7.5 400 6–7/9–10 2x10.9

EI422 1223 230 1–5 2x9 334 6–7/9–10 2x13.0

EI422 1225 230 1–5 2x12 250 6–7/9–10 2x16.7

EI422 1227 230 1–5 2x15 200 6–7/9–10 2x20.6

EI422 1229 230 1–5 2x18 167 6–7/9–10 2x24.6

Yellow field are normaly in stock

Part NoPrimary Secondary

Vacuum casted safety PCB transformer, with one or two secondary windings. The dual

secondary windings can be ether serial or parallel connected. Use a PTC-resistor as overload

protection. 2*115 V on the primary side on request.

External fuse or PTC

Series EI422 - 6VA

Part No

Primary Secondary

2 3 4 5

109 8 7

6

1112

55,0

64,0

EI422 25,0

1

5x5,0

43,8

Prim

36,8

32,3

2 3 4 5

109 8 7

6

1112

12 3 4 5

109 8 7

6

1112

1

Sec

Mounting hole

Dia. 4,2Single secondary

winding

Dual secondarywindings

Bottom view

equipped pins

Soldering pin

0,6x0,8x5

[mm]

www.flexitron.se 32/63

Page 33: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Primary: 230V~ ±10% 50-60Hz

Different voltage on request

Max primary current: 48 mA at full load

Secondary: 6 - 24V~, ±5%

Power: 6VA

Temperature class: ta70/B

Isolation: 4kV/10mm/classII

Standard: EN 61558

Approvals: ENEC (Europe)

UL/CSA (USA, Canada)

Overload protection:

Test: 100% (all individuals)

Weight: 200 g

Single secondary voltage 6VA ta70/B

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI422 1320 230 1–5 1x6 1000 7–9 1x8.7

EI422 1303 230 1–5 1x7.5 800 7–9 1x10.9

EI422 1285 230 1–5 1x9 667 7–9 1x13.0

EI422 1275 230 1–5 1x12 500 7–9 1x16.7

EI422 1276 230 1–5 1x15 400 7–9 1x20.2

EI422 1289 230 1–5 1x18 334 7–9 1x24.6

EI422 1307 230 1–5 1x24 250 7–9 1x30.8

Dual secondary voltage 6VA ta70/B

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI422 1298 230 1–5 2x6 500 6–7/9–10 2x8.7

EI422 1304 230 1–5 2x7.5 400 6–7/9–10 2x10.9

EI422 1281 230 1–5 2x9 334 6–7/9–10 2x13.0

EI422 1260 230 1–5 2x12 250 6–7/9–10 2x16.7

EI422 1305 230 1–5 2x15 200 6–7/9–10 2x20.6

EI422 1306 230 1–5 2x18 167 6–7/9–10 2x24.6

Yellow field are normaly in stock

Part NoPrimary Secondary

Vacuum casted safety PCB transformer, with one or two secondary windings. The dual

secondary windings can be ether serial or parallel connected. Use a PTC-resistor as overload

protection. 2*115 V on the primary side on request.

External fuse or PTC

(not included)

Series EI422 - 6VA, without mounting flanges

Part NoPrimary Secondary

2 3 4 5

109 8 7

6

1112

EI422 25,0

1

5x5,0

43,8

Prim

36,8

32,3

2 3 4 5

109 8 7

6

1112

12 3 4 5

109 8 7

6

1112

1

Sec

Single secondarywinding

Dual secondarywindings

Bottom view

equipped pins

Soldering pin

0,6x0,8x5

[mm]

www.flexitron.se 33/63

Page 34: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Primary: Max 500V~

Secondary: Max 250V~

Power: 10VA

Temperature class: ta70/B

Isolation: 4kv/10mm/classII

Standard: EN 61558

Approvals: In application.

Overload protection:

Test:

Weight: 250 g

Standard types not define. Manufacture on order, according to customer specification.

Vacuum casted safety PCB transformer. Customer specific design. Symmetric and asymmetric

bobbins and pins are possible. Provide with both internal and external overload protection.

Series EI423 - 10VA

100% (All individuals)

1-2 bobbins.

1-2 bobbins.

External or internal.

According to requirements.

2 3 4 5

109 8 7

6

1112

55,0

64,0

EI423 25,0

1

5x5,0

43,8

Prim

36,8

38,0

2 3 4 5

10 9 8 7

6

1112

12 3 4 5

109 8 7

6

1112

1

Sec

Mounting hole

Dia. 4,2Single secondary

winding

Dual secondary

windings

Bottom view

equipped pins

Soldering pin

0,6x0,8x5

[mm]

www.flexitron.se 34/63

Page 35: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Primary: 230V~ ±10% 50-60Hz

Different voltage on request

Max primary current: 65 mA at full load

Secondary: 6 - 24V~, ±5%

Power: 7VA

Temperature class: ta70/B

Isolation: 4kV/10mm/classII

Standard: EN 61558

Approvals: ENEC (Europe)

UL/CSA (USA, Canada)

Overload protection:

Test: 100% (all individuals)

Weight: 250 g

Single secondary voltage 7VA ta70/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI480 1227 230 1–6 1x6 1167 8–11 1x7.6

EI480 1230 230 1–6 1x7.5 934 8–11 1x10.1

EI480 1219 230 1–6 1x9 788 8–11 1x11.6

EI480 1222 230 1–6 2x12 292 8–11 2x15.4

EI480 1223 230 1–6 1x15 467 8–11 1x18.9

EI480 1225 230 1–6 1x18 389 8–11 1x22.3

EI480 1226 230 1–6 1x24 292 8–11 1x29.4

Dual secondary voltage 7VA ta70/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI480 1228 230 1–6 2x6 583 7–8/11–12 2x7.6

EI480 1218 230 1–6 2x7.5 467 7–8/11–12 2x10.1

EI480 1220 230 1–6 2x9 388 7–8/11–12 2x11.6

EI480 1221 230 1–6 1x12 583 7–8/11–12 1x15.2

EI480 1224 230 1–6 2x15 233 7–8/11–12 2x19.0

EI480 1229 230 1–6 2x18 195 7–8/11–12 2x22.3

Yellow field are normaly in stock

Part NoPrimary Secondary

Series EI480 - 7VA

Vacuum casted safety PCB transformer, with one or two secondary windings. The dual

secondary windings can be ether serial or parallel connected. Use a PTC-resistor as overload

protection. 2*115 V on the primary side on request.

External fuse or PTC

Part NoPrimary Secondary

2 3 4 5 612 3 4 5 61

9 8 71112 109 8 71112 10

EI 480 42,1

9 8 71112 10Sec

Prim

49,9

60,0

69,0

2 3 4 5 61

5x5,0

27,5

29,5

[mm]

Bottom viewequipped pins

Soldering pin 0,5x1,1x5

Single secondary

winding

Dual secondary

windings

Mounting hole

dia = 4,2

www.flexitron.se 35/63

Page 36: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Primary: 230V~ ±10% 50-60Hz

Different voltage on request

Max primary current: 75 mA at full load

Secondary: 6 - 24V~, ±5%

Power: 10VA

Temperature class: ta70/B

Isolation: 4kV/10mm/classII

Standard: EN 61558

Approvals: ENEC (Europe)

UL/CSA (USA, Canada)

Overload protection:

Test: 100% (all individuals)

Weight: 300 g

Single secondary voltage 10VA ta70/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI481 1142 230 1–6 1x6 1667 8–11 1x7.6

EI481 1182 230 1–6 1x7.5 1333 8–11 1x9.8

EI481 1167 230 1–6 1x9 1111 8–11 1x11.5

EI481 1172 230 1–6 1x12 833 8–11 1x15.5

EI481 1184 230 1–6 1x15 667 8–11 1x18.6

EI481 1185 230 1–6 1x18 556 8–11 1x22.3

EI481 1186 230 1–6 1x24 416 8–11 1x28.7

Dual secondary voltage 10VA ta70/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI481 1134 230 1–6 2x6 833 7–8/11–12 2x7.6

EI481 1188 230 1–6 2x7.5 667 7–8/11–12 2x9.8

EI481 1118 230 1–6 2x9 556 7–8/11–12 2x11.5

EI481 1119 230 1–6 2x12 417 7–8/11–12 2x15.3

EI481 1120 230 1–6 2x15 333 7–8/11–12 2x18.6

EI481 1192 230 1–6 2x18 278 7–8/11–12 2x22.3

Yellow field are normaly in stock

Part NoPrimary Secondary

Series EI481 - 10VA

Vacuum casted safety PCB transformer, with one or two secondary windings. The dual

secondary windings can be ether serial or parallel connected. Use a PTC-resistor as

overload protection. 2*115 V on the primary side on request.

External fuse or PTC

Part NoPrimary Secondary

2 3 4 5 612 3 4 5 61

9 8 71112 109 8 71112 10

EI 481 42,1

9 8 71112 10Sec

Prim

34,649,9

60,0

69,0

2 3 4 5 61

5x5,0

27,5

[mm]

Bottom view

equipped pins

Soldering pin

0,5x1,1x5

Single secondarywinding

Dual secondarywindings

Mounting holedia = 4,2

www.flexitron.se 36/63

Page 37: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Primary: 230V~ ±10% 50-60Hz

Different voltage on request

Max primary current: 75 mA at full load

Secondary: 6 - 24V~, ±5%

Power: 10VA

Temperature class: ta70/B

Isolation: 4kV/10mm/classII

Standard: EN 61558

Approvals: ENEC (Europe)

UL/CSA (USA, Canada)

Overload protection:

Test: 100% (all individuals)

Weight: 300 g

Single secondary voltage 10VA ta70/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI481 1142 230 1–6 1x6 1667 8–11 1x7.6

EI481 1182 230 1–6 1x7.5 1333 8–11 1x9.8

EI481 1167 230 1–6 1x9 1111 8–11 1x11.5

EI481 1172 230 1–6 1x12 833 8–11 1x15.5

EI481 1184 230 1–6 1x15 667 8–11 1x18.6

EI481 1185 230 1–6 1x18 556 8–11 1x22.3

EI481 1186 230 1–6 1x24 416 8–11 1x28.7

Dual secondary voltage 10VA ta70/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI481 1134 230 1–6 2x6 833 7–8/11–12 2x7.6

EI481 1188 230 1–6 2x7.5 667 7–8/11–12 2x9.8

EI481 1118 230 1–6 2x9 556 7–8/11–12 2x11.5

EI481 1119 230 1–6 2x12 417 7–8/11–12 2x15.3

EI481 1120 230 1–6 2x15 333 7–8/11–12 2x18.6

EI481 1192 230 1–6 2x18 278 7–8/11–12 2x22.3

Yellow field are normaly in stock

Part NoPrimary Secondary

Series EI481 - 10VA, without mounting flanges

Vacuum casted safety PCB transformer, with one or two secondary windings. The dual

secondary windings can be ether serial or parallel connected. Use a PTC-resistor as

overload protection. 2*115 V on the primary side on request.

External fuse or PTC

Part NoPrimary Secondary

2 3 4 5 612 3 4 5 61

9 8 71112 109 8 71112 10

EI 481 42,1

9 8 71112 10Sec

Prim

34,649,9

60,0

2 3 4 5 61

5x5,0

27,5

[mm]

Bottom view

equipped pins

Soldering pin

0,5x1,1x5

Single secondarywinding

Dual secondarywindings

www.flexitron.se 37/63

Page 38: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Primary: 230V~ ±10% 50-60Hz

Different voltage on request

Max primary current:90 mA vid full last

Secondary: 6 - 24V~, ±5%

Power: 12VA

Temperature class: ta70/B

Isolation: 4kV/10mm/classII

Standard: EN 61558

Approvals: ENEC (Europe)

UL/CSA (USA, Canada)

Overload protection:

Test: 100% (all individuals)

Weight: 350 g

Single secondary voltage 12VA ta70/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI482 1231 230 1–6 1x6 2000 8–11 1x8.3

EI482 1233 230 1–6 1x7.5 1600 8–11 1x10.6

EI482 1237 230 1–6 1x9 1333 8–11 1x12.4

EI482 1239 230 1–6 1x12 1000 8–11 1x16.3

EI482 1241 230 1–6 1x15 800 8–11 1x19.9

EI482 1243 230 1–6 1x18 667 8–11 1x23.5

EI482 1244 230 1–6 1x24 500 8–11 1x30.3

Dual secondary voltage 12VA ta70/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI482 1232 230 1–6 2x6 1000 7–8/11–12 2x8.3

EI482 1236 230 1–6 2x7.5 800 7–8/11–12 2x10.6

EI482 1238 230 1–6 2x9 667 7–8/11–12 2x12.4

EI482 1240 230 1–6 2x12 500 7–8/11–12 2x16.3

EI482 1242 230 1–6 2x15 400 7–8/11–12 2x19.9

EI482 1234 230 1–6 2x18 333 7–8/11–12 2x23.5

Yellow field are normaly in stock

Part NoPrimary Secondary

Series EI482 - 12VA

Part NoPrimary Secondary

Vacuum casted safety PCB transformer, with one or two secondary windings. The dual

secondary windings can be ether serial or parallel connected. Use a PTC-resistor as

overload protection. 2*115 V on the primary side on request.

External fuse or PTC

2 3 4 5 612 3 4 5 61

9 8 71112 109 8 71112 10

EI 482 42,1

9 8 71112 10Sec

Prim

38,549,9

60,0

69,0

2 3 4 5 61

5x5,0

27,5

[mm]

Bottom viewequipped pins

Soldering pin 0,5x1,1x5

Single secondarywinding

Dual secondary

windings

Mounting hole

dia = 4,2

www.flexitron.se 38/63

Page 39: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Primary: 230V~ ±10% 50-60Hz

Different voltage on request

Max primary current: 110 mA at full load

Secondary: 6 - 24V~, ±5%

Power: 15VA

Temperature class: ta70/B

Isolation: 4kV/10mm/classII

Standard: EN 61558

Approvals: ENEC (Europe)

UL/CSA (USA, Canada)

Overload protection:

Test: 100% (all individuals)

Weight: 450 g

Single secondary voltage 15VA ta70/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI483 1260 230 1–6 1x6 2500 8–11 1x7.8

EI483 1258 230 1–6 1x7.5 2000 8–11 1x9.5

EI483 1246 230 1–6 1x9 1667 8–11 1x12.0

EI483 1248 230 1–6 1x12 1250 8–11 1x15.9

EI483 1250 230 1–6 1x15 1000 8–11 1x19.1

EI483 1252 230 1–6 1x18 833 8–11 1x22.8

EI483 1253 230 1–6 1x24 625 8–11 1x30.6

Dual secondary voltage 15VA ta70/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI483 1257 230 1–6 2x6 1250 7–8/11–12 2x7.8

EI483 1245 230 1–6 2x7.5 1000 7–8/11–12 2x9.5

EI483 1247 230 1–6 2x9 833 7–8/11–12 2x12.0

EI483 1249 230 1–6 2x12 625 7–8/11–12 2x15.9

EI483 1251 230 1–6 2x15 500 7–8/11–12 2x19.1

EI483 1259 230 1–6 2x18 417 7–8/11–12 2x22.8

Yellow field are normaly in stock

Part NoPrimary Secondary

Series EI483 - 15VA

Part NoPrimary Secondary

Vacuum casted safety PCB transformer, with one or two secondary windings. The dual

secondary windings can be ether serial or parallel connected. Use a PTC-resistor as overload

protection. 2*115 V on the primary side on request.

External fuse or PTC

(not included)

2 3 4 5 612 3 4 5 61

9 8 71112 109 8 71112 10

EI 483 42,1

9 8 71112 10Sec

Prim

44,049,9

60,0

69,0

2 3 4 5 61

5x5,0

27,5

[mm]

Bottom viewequipped pins

Soldering pin 0,5x1,1x5

Single secondary

winding

Dual secondary

windings

Mounting hole

dia = 4,2

www.flexitron.se 39/63

Page 40: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Primary: 230V~ ±10% 50-60Hz

Different voltage on request

Max primary current: 110 mA at full load

Secondary: 6 - 24V~, ±5%

Power: 12VA

Temperature class: ta70/B

Isolation: 4kV/10mm/classII

Standard: EN 61558

Approvals: ENEC (Europe)

UL/CSA (USA, Canada)

Overload protection:

Test: 100% (all individuals)

Weight: 350 g

Single secondary voltage 12VA ta70/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI540 1137 230 1–7 1x6 2000 9–13 1x8.1

EI540 1139 230 1–7 1x7.5 1600 9–13 1x9.9

EI540 1141 230 1–7 1x9 1333 9–13 1x12.2

EI540 1143 230 1–7 1x12 1000 9–13 1x15.8

EI540 1145 230 1–7 1x15 800 9–13 1x19.4

EI540 1147 230 1–7 1x18 667 9–13 1x23.5

EI540 1149 230 1–7 1x24 500 9–13 1x30.6

Series EI540 - 12VA

Vacuum casted safety PCB transformer, with one or two secondary windings. The dual

secondary windings can be ether serial or parallel connected. Use a PTC-resistor as

overload protection. 2*115 V on the primary side on request.

External fuse or PTC

(not included)

Part No

Primary Secondary

65,0

75,2

30,0

6x5,0

56,4

37,5

EI540

2 3 4 5 61

9 8

7

1112 10141347,5

37,5Prim

Sec

Höjd

33,7

2 3 4 5 61

9 8

7

1112 101413

2 3 4 5 61

9 8

7

1112 101413

Sigle secondary

Dual secondary

[mm]Mounting holedia 4,2 mm

Bottom view Equipped pins

Soldering pin 0,5x1,0x5,7

www.flexitron.se 40/63

Page 41: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Dual secondary voltage 12VA ta70/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI540 1138 230 1–7 2x6 1000 8–9/13–14 2x8.1

EI540 1140 230 1–7 2x7.5 800 8–9/13–14 2x9.9

EI540 1142 230 1–7 2x9 667 8–9/13–14 2x12.2

EI540 1144 230 1–7 2x12 500 8–9/13–14 2x15.8

EI540 1146 230 1–7 2x15 400 8–9/13–14 2x19.4

EI540 1148 230 1–7 2x18 334 8–9/13–14 2x23.5

Secondary

Part No

Primary

www.flexitron.se 41/63

Page 42: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Primary: 230V~ ±10% 50-60Hz

Different voltage on request

Max primary current: 110 mA at full load

Secondary: 6 - 24V~, ±5%

Power: 16VA

Temperature class: ta70/B

Isolation: 4kV/10mm/classII

Standard: EN 61558

Approvals: ENEC (Europe)

UL/CSA (USA, Canada)

Overload protection:

Test: 100% (all individuals)

Weight: 400 g

Single secondary voltage 16VA ta70/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI541 1121 230 1–7 1x6 2667 9–13 1x7.9

EI541 1122 230 1–7 1x7.5 2134 9–13 1x9.7

EI541 1123 230 1–7 1x9 1778 9–13 1x11.7

EI541 1124 230 1–7 1x12 1333 9–13 1x15.2

EI541 1125 230 1–7 1x15 1067 9–13 1x19.1

EI541 1126 230 1–7 1x18 889 9–13 1x22.3

EI541 1110 230 1–7 1x24 667 9–13 1x29.1

Series EI541 - 16VA

Vacuum casted safety PCB transformer, with one or two secondary windings. The dual

secondary windings can be ether serial or parallel connected. Use a PTC-resistor as overload

protection. 2*115 V on the primary side on request.

External fuse or PTC

(not included)

Part NoPrimary Secondary

65,0

75,2

30,0

6x5,0

56,4

37,5

EI541

2 3 4 5 61

9 8

7

1112 10141347,5

37,5Prim

Sec

Höjd

38,8

2 3 4 5 61

9 8

7

1112 101413

2 3 4 5 61

9 8

7

1112 101413

Sigle secondary

Dual secondary

[mm] Mounting hole, dia 4,2 mm

Bottom view

Equipped pins

Soldering pin

0,5x1,0x5,7

www.flexitron.se 42/63

Page 43: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Dual secondary voltage 16VA ta70/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI541 1128 230 1–7 2x6 1334 8–9/13–14 2x7.9

EI541 1129 230 1–7 2x7.5 1067 8–9/13–14 2x9.7

EI541 1130 230 1–7 2x9 889 8–9/13–14 2x11.7

EI541 1131 230 1–7 2x12 667 8–9/13–14 2x15.2

EI541 1132 230 1–7 2x15 534 8–9/13–14 2x19.1

EI541 1150 230 1–7 2x18 445 8–9/13–14 2x22.3

Yellow field are normaly in stock

Part No

Primary Secondary

www.flexitron.se 43/63

Page 44: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Primary: 230V~ ±10% 50-60Hz

Different voltage on request

Max primary current: 130 mA at full load

Secondary: 6 - 24V~, ±5%

Power: 20VA

Temperature class: ta70/B

Isolation: 4kV/10mm/classII

Standard: EN 61558

Approvals: ENEC (Europe)

UL/CSA (USA, Canada)

Overload protection:

Test: 100% (all individuals)

Weight: 500 g

Single secondary voltage 20VA ta70/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI542 1151 230 1–7 1x6 3334 9–13 1x7.7

EI542 1153 230 1–7 1x7.5 2667 9–13 1x9.5

EI542 1155 230 1–7 1x9 2223 9–13 1x11.4

EI542 1157 230 1–7 1x12 1667 9–13 1x15.0

EI542 1159 230 1–7 1x15 1334 9–13 1x18.6

EI542 1161 230 1–7 1x18 1112 9–13 1x21.8

EI542 1163 230 1–7 1x24 834 9–13 1x29.5

Dual secondary voltage 20VA ta70/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI542 1152 230 1–7 2x6 1667 8–9/13–14 2x7.7

EI542 1154 230 1–7 2x7.5 1334 8–9/13–14 2x9.5

EI542 1156 230 1–7 2x9 1112 8–9/13–14 2x11.4

EI542 1158 230 1–7 2x12 834 8–9/13–14 2x15.0

EI542 1160 230 1–7 2x15 667 8–9/13–14 2x18.6

EI542 1162 230 1–7 2x18 556 8–9/13–14 2x21.8

Yellow field are normaly in stock

Part No

Primary Secondary

Series EI542 - 20VA

Part No

Primary Secondary

Vacuum casted safety PCB transformer, with one or two secondary windings. The dual

secondary windings can be ether serial or parallel connected. Use a PTC-resistor as overload

protection. 2*115 V on the primary side on request.

External fuse or PTC

(not included)

65,0

75,2

30,0

6x5,0

56,4

37,5

EI542

2 3 4 5 61

9 8

7

1112 10141347,5

37,5Prim

Sec

Höjd

43,2

2 3 4 5 61

9 8

7

1112 101413

2 3 4 5 61

9 8

7

1112 101413

Sigle secondary

Dual secondary

[mm] Mounting hole, dia 4,2 mm

Bottom view

Equipped pins

Soldering pin

0,5x1,0x5,7

www.flexitron.se 44/63

Page 45: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Primary: 230V~ ±10% 50-60Hz

Different voltage on request

Max primary current: 165 mA at full load

Secondary: 6 - 24V~, ±5%

Power: 22VA

Temperature class: ta70/B

Isolation: 4kV/10mm/cklassII

Standard: EN 61558

Approvals: ENEC (Europe)

UL/CSA (USA, Canada)

Overload protection:

Test: 100% (all individuals)

Weight: 550 g

Single secondary voltage 22VA ta70/F

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI543 1166 230 1–7 1x6 3667 9–13 1x7.4

EI543 1168 230 1–7 1x7.5 2934 9–13 1x8.9

EI543 1170 230 1–7 1x9 2445 9–13 1x10.7

EI543 1172 230 1–7 1x12 1834 9–13 1x14.5

EI543 1174 230 1–7 1x15 1467 9–13 1x17.9

EI543 1176 230 1–7 1x18 1223 9–13 1x21.0

EI543 1178 230 1–7 1x24 917 9–13 1x28.0

Series EI543 - 22VA

Part No

Primary Secondary

Vacuum casted safety PCB transformer, with one or two secondary windings. The dual

secondary windings can be ether serial or parallel connected. Use a PTC-resistor as

overload protection. 2*115 V on the primary side on request.

External fuse or PTC

(not included)

65,0

75,2

30,0

6x5,0

56,4

37,5

EI543

2 3 4 5 61

9 8

7

1112 10141347,5

37,5Prim

Sec

Höjd

47,4

2 3 4 5 61

9 8

7

1112 101413

2 3 4 5 61

9 8

7

1112 101413

Sigle secondary

Dual secondary

[mm] Mounting hole, dia 4,2 mm

Bottom view

Equipped pins

Soldering pin

0,5x1,0x5,7

www.flexitron.se 45/63

Page 46: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Dual secondary voltage 22VA ta70/F

Part No Primary Secondary

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

EI543 1167 230 1–7 2x6 1834 8–9/13–14 2x7.4

EI543 1169 230 1–7 2x7.5 1467 8–9/13–14 2x8.9

EI543 1171 230 1–7 2x9 1223 8–9/13–14 2x10.7

EI543 1173 230 1–7 2x12 917 8–9/13–14 2x14.5

EI543 1175 230 1–7 2x15 734 8–9/13–14 2x17.9

EI543 1177 230 1–7 2x18 612 8–9/13–14 2x21.0

www.flexitron.se 46/63

Page 47: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Primary voltage: 1x230V~ or

2x115V~ ±10 % 50-60 Hz

Different voltage on request.

Max primary current: 21 mA

Secondary voltage, rms 3-24V~ or 2x 3-21V~, ±5%

Power: 1VA

Temperature class: ta70/B

Isolation: 4kV/10mm/classII

Standard: EN 61558

Approvals: ENEC (Europe)

UL/CSA (USA, Canada)

Overload protection:

Test: 100% (Alla enheter)

Weight 50 g

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

UI21 0011 230 1-3 3 333 7-8 4.7

UI21 0012 230 1-3 6 166 7-8 10.4

UI21 0013 230 1-3 7.5 133 7-8 12.9

UI21 0014 230 1-3 9 111 7-8 14.4

UI21 0015 230 1-3 10 100 7-8 15.4

UI21 0016 230 1-3 12 83 7-8 20.4

UI21 0017 230 1-3 15 67 7-8 24.6

UI21 0018 230 1-3 18 56 7-8 29.1

UI21 0019 230 1-3 21 47 7-8 34

UI21 0021 230 1-3 24 42 7-8 39.7

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

UI21 0001 2x 115 1-3/4-6 2x 3 166 7-8/11-12 2x 5.8

UI21 0002 2x 115 1-3/4-6 2x 6 82 7-8/11-12 2x 11.4

UI21 0008 2x 115 1-3/4-6 2x 7.5 67 7-8/11-12 2x 13.1

UI21 0003 2x 115 1-3/4-6 2x 9 56 7-8/11-12 1x 17.1

UI21 0004 2x 115 1-3/4-6 2x 12 41 7-8/11-12 2x 21.8

Yellow field are normaly in stock

Part No

Primary Secondary

Vacuum casted PCB transformer. Low profile design. With one primary and one secondary or

dual primary and secondary. short circuit proof. Fuse and other external protection is not

needed.

Single primary- and secondary voltage 1VA ta70/F

Dual primary- and secondary voltage 1VA ta70/F

Series UI21 - 1VA

Part No

Primary Secondary

Not needed.

Prim

Sec

Single primary/secondary

20,0UI21

9 81112 10 7

2 3 4 5 61

29,0

5,0 3,5

Dual primary/secondary

Prim

20,0

Sec

UI21

9 81112 10 7

2 3 4 5 61

29,0

5,0 3,5

15,0

33,5

Bottom view

Equipped pins

[mm]

www.flexitron.se 47/63

Page 48: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Primary voltage: 2×115 V~ ±10 % 50-60 Hz

Different voltage on inquiry.

Max primary current: 35 mA at full load.

Secondary voltage, rms 2x 6-24V~, ±5%

Power: 3 VA

Temperature class: ta70/B

Isolation: 4kV/10mm/classII

Standard: EN 61558

Approvals: ENEC (Europe)

UL/CSA (USA, Canada)

Overload protection:

Test:

Weight: 130 g

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

UI301 0167 2x115 1-3/6-8 2x6 250 10-12/13-15 2x7.9

UI301 0168 2x115 1-3/6-8 2x9 167 10-12/13-15 2x14.0

UI301 0133 2x115 1-3/6-8 2x12 126 10-12/13-15 2x18.5

UI301 0166 2x115 1-3/6-8 2x15 100 10-12/13-15 2x22.8

UI301 0146 2x115 1-3/6-8 2x18 83 10-12/13-15 2x27.1

UI301 0157 2x115 1-3/6-8 2x21 71 10-12/13-15 2x31.6

UI301 0132 2x120 1-3/6-8 2x9 167 10-12/13-15 2x13.6

Yellow field are normaly in stock

External fuse or PTC- resistance

(not included)

Vacuum castad PCB transformer with low profile design. Provided with mounting hole in the

corners. Dual primary and secondary windings (2x115V on prim.). The secondary windings can

be ether series or parallel connected. As overload protection use a PTC- resistance.

Series UI301 - 3VA

Part No

Primary Secondary

100% (All individuals)

Dual primary and secondary voltage 3,0VA ta70/F

4 Screwhole: dia 2.4mm on top and bottom.Screw type: metalscrew 2.9x6.5mm.

Bottom viewEquipped pins

37,5

44,2

1 2 3 4 5 6 7 8

9

UI30135,0

16 15 14 13 12 11 10

7x5,0

47,5

Prim

Sec

53,0

17,8

[mm]

www.flexitron.se 48/63

Page 49: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Primary voltage: 2×115 V~ ±10 % 50-60 Hz

Different voltage on inquiry.

Max primary current: 40 mA at full load.

Secondary voltage, rms 2x 6-24V~, ±5%

Power: 4 VA

Temperature class: ta70/B

Isolation: 4kV/10mm/classII

Standard: EN 61558

Approvals: ENEC (Europe)

UL/CSA (USA, Canada)

Overload protection:

Test:

Weight: 150 g

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

UI302 0164 2x115 1-3/6-8 2x6 333 10-12/13-15 2x9.5

UI302 0161 2x115 1-3/6-8 2x9 222 10-12/13-15 2x13.5

UI302 0144 2x115 1-3/6-8 2x12 166 10-12/13-15 2x20.1

UI302 0165 2x115 1-3/6-8 2x15 133 10-12/13-15 2x24.9

UI302 0156 2x115 1-3/6-8 2x18 111 10-12/13-15 2x30.4

UI302 0169 2x115 1-3/6-8 2x21 95 10-12/13-15 2x35.1

Yellow field are normaly in stock

Vacuum castad PCB transformer with low profile design. Provided with mounting hole in the

corners. Dual primary and secondary windings (2x115V on prim.). The secondary windings can

be ether series or parallel connected. As overload protection use a PTC- resistance.

Series UI302 - 4VA

100% (All individuals)

Part No

Primary Secondary

External fuse or PTC- resistance

(not included)

Dual primary and secondary voltage 4,0VA ta70/F

37,5

44,2

1 2 3 4 5 6 7 8

9

UI30235,0

16 15 14 13 12 11 10

7x5,0

47,553,0

19,8

Prim

Bottom view.Equipped pins.

4 screwhole: dia 2.4mm on top and bottom.

Screw type: metalscrew 2.9x6.5mm.

Sec

[mm]

www.flexitron.se 49/63

Page 50: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Primary voltage: 2×115 V~ ±10 % 50-60 Hz

Different voltage on inquiry.

Max primary current: 50 mA at full load.

Secondary voltage, rms 2x 6-24V~, ±5%

Power: 6 VA

Temperature class: ta70/B

Isolation: 4kV/10mm/cklassII

Standard: EN 61558

Approvals: ENEC (Europe)

UL/CSA (USA, Canada)

Overload protection:

Test:

Weight: 180 g

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

UI303 0162 2x115 1-3/6-8 2x6 500 10-12/13-15 2x9

UI303 0158 2x115 1-3/6-8 2x9 334 10-12/13-15 2x12.8

UI303 0145 2x115 1-3/6-8 2x12 250 10-12/13-15 2x17.2

UI303 0163 2x115 1-3/6-8 2x15 200 10-12/13-15 2x21.8

UI303 0143 2x115 1-3/6-8 2x18 166 10-12/13-15 2x26

UI303 0170 2x115 1-3/6-8 2x21 143 10-12/13-15 2x29.7

Yellow field are normaly in stock

Part No

Primary Secondary

External fuse or PTC- resistance

(not included)

Vacuum castad PCB transformer with low profile design. Provided with mounting hole in the

corners. Dual primary and secondary windings (2x115V on prim.). The secondary windings can

be ether series or parallel connected. As overload protection use a PTC- resistance.

Series UI303 - 6VA

100% (All individuals)

Dual primary and secondary voltage 6,0VA ta70/F

37,5

44,2

1 2 3 4 5 6 7 8

9

UI30335,0

16 15 14 13 12 11 10

7x5,0

47,5

Prim

53,0

22,8Bottom view.Equipped pins.

4 screwhole: dia 2.4mm on top and bottom.

Screw type: metalscrew 2.9x6.5mm.

Sec

[mm]

www.flexitron.se 50/63

Page 51: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Primary voltage: 2×115 V~ ±10 % 50-60 Hz

Different voltage on inquiry.

Max primary current: 70 mA at full load.

Secondary voltage, rms 2x 6-24V~, ±5%

Power: 10 VA

Temperature class: ta70/B

Isolation: 4kV/10mm/classII

Standard: EN 61558

Approvals: ENEC (Europe)

UL/CSA (USA, Canada)

Overload protection:

Test:

Weight: 260 g

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

UI304 0155 2x115 1-3/6-8 2x 6 833 10-12/13-15 2x8.7

UI304 0129 2x115 1-3/6-8 2x7.5 667 10-12/13-15 2x10

UI304 0153 2x115 1-3/6-8 2x9 555 10-12/13-15 2x12.4

UI304 0154 2x115 1-3/6-8 2x12 416 10-12/13-15 2x16

UI304 0136 2x115 1-3/6-8 2x15 333 10-12/13-15 2x19.7

UI304 0159 2x115 1-3/6-8 2x18 277 10-12/13-15 2x23.3

UI304 0171 2x120 1-3/6-8 2x6 833 10-12/13-15 2x8.7

UI304 0172 2x120 1-3/6-8 2x15 333 10-12/13-15 2x19.7

UI304 0135 2x120 1-3/6-8 2x18 277 10-12/13-15 2x23.3

UI304 0173 2x115 1-3/6-8 2x21 238 10-12/13-15 2x27.2

Yellow field are normaly in stock

External fuse or PTC- resistance

(not included)

Vacuum castad PCB transformer with low profile design. Provided with mounting hole in the

corners. Dual primary and secondary windings (2x115V on prim.). The secondary windings can

be ether series or parallel connected. As overload protection use a PTC- resistance.

Series UI304 - 10VA

Part No

Primary Secondary

100% (All individuals)

Dual primary and secondary voltage 10VA ta70/F

Bottom view.

Equipped pins.

4 screwhole: dia 2.4mm on top and bottom.Screw type: metalscrew 2.9x6.5mm.

Sec

37,5

44,2

1 2 3 4 5 6 7 8

9

UI30435,0

16 15 14 13 12 11 10

7x5,0

47,553,0

28,8

Prim

[mm]

www.flexitron.se 51/63

Page 52: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Primary voltage: 2×115 V~ ±10 % 50-60 Hz

Different voltage on inquiry.

Max primary current: 110 mA at full load.

Secondary voltage, rms 2x 6-24V~, ±5%

Power: 16 VA

Temperature class: ta70/B

Isolation: 4kV/10mm/classII

Standard: EN 61558

Approvals: ENEC (Europe)

UL/CSA (USA, Canada)

Overload protection:

Test:

Weight: 370 g

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

UI305 0147 2x 115 1-3/6-8 2x6 1330 10-12/13-15 2x7.5

UI305 0148 2x 115 1-3/6-8 2x9 888 10-12/13-15 2x10.9

UI305 0149 2x 115 1-3/6-8 2x12 666 10-12/13-15 2x14.6

UI305 0150 2x 115 1-3/6-8 2x15 533 10-12/13-15 2x18

UI305 0151 2x 115 1-3/6-8 2x18 444 10-12/13-15 2x21.5

UI305 0152 2x 115 1-3/6-8 2x21 380 10-12/13-15 2x25

Yellow field are normaly in stock

External fuse or PTC- resistance

(not included)

Vacuum castad PCB transformer with low profile design. Provided with mounting hole in the

corners. Dual primary and secondary windings (2x115V on prim.). The secondary windings can

be ether series or parallel connected. As overload protection use a PTC- resistance.

Series UI305 - 16VA

Part No

Primary Secondary

100% (All individuals)

Dual primary and secondary voltage 16VA ta70/F

Bottom view.Equipped pins.

37,5

44,2

1 2 3 4 5 6 7 8

9

UI30535,0

16 15 14 13 12 11 10

7x5,0

47,5 53,0

4 screwhole: dia 2.4mm on top and bottom.Screw type: metalscrew 2.9x6.5mm.

37,6

Prim

Sec

[mm]

www.flexitron.se 52/63

Page 53: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Primary voltage: 2×115 V~ ±10 % 50-60 Hz

Different voltage on inquiry.

Max primary current: 80 mA at full load.

Secondary voltage, rms 2x 6-24V~, ±5%

Power: 10 VA

Temperature class: ta70/B

Isolation: 4kV/10mm/classII

Standard: EN 61558

Approvals: ENEC (Europe)

UL/CSA (USA, Canada)

Overload protection:

Test:

Weight: 290 g

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

UI392 0092 2x115 1-3/8-10 2x6 833 12-14/17-19 2x8.2

UI392 0076 2x115 1-3/8-10 2x9 556 12-14/17-19 2x11.9

UI392 0093 2x115 1-3/8-10 2x12 416 12-14/17-19 2x16.4

UI392 0077 2x115 1-3/8-10 2x15 333 12-14/17-19 2x19.3

UI392 0094 2x115 1-3/8-10 2x18 277 12-14/17-19 2x23.8

UI392 0095 2x115 1-3/8-10 2x21 238 12-14/17-19 2x27.2

Yellow field are normaly in stock

Part NoPrimary Secondary

External fuse or PTC- resistance

(not included)

Vacuum castad PCB transformer with low profile design. Provided with mounting hole in the

corners. Dual primary and secondary windings (2x115V on prim.). The secondary windings can

be ether series or parallel connected. As overload protection use a PTC- resistance.

Series UI392 - 10VA

100% (All individuals)

Dual primary and secondary voltage 10VA ta70/F

50,0

57,3

UI39245,0

4x5,0

62,568,2

23,0

1 2 3 54 6 7 8 9

4x5,06,0

16 15141312 11

10

17181920

Prim

Sec

Soldering pin

0,6x0,8x4

Bottom view.

Equipped pins.

4 screwhole: dia 2.4mm on top and bottom.

Screw type: metalscrew 2.9x6.5mm.

[mm]

www.flexitron.se 53/63

Page 54: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Primary voltage: 2×115 V~ ±10 % 50-60 Hz

Different voltage on inquiry.

Max primary current: 100 mA at full load.

Secondary voltage, rms 2x 6-24V~, ±5%

Power: 14 VA

Temperature class: ta70/B

Isolation: 4kV/10mm/classII

Standard: EN 61558

Approvals: ENEC (Europe)

UL/CSA (USA, Canada)

Overload protection:

Test:

Weight: 330 g

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

UI393 0085 2x115 1-3/8-10 2x6 1166 12-14/17-19 2x8.3

UI393 0074 2x115 1-3/8-10 2x9 778 12-14/17-19 2x14.4

UI393 0081 2x115 1-3/8-10 2x12 583 12-14/17-19 2x16.4

UI393 0078 2x115 1-3/8-10 2x15 467 12-14/17-19 2x20.6

UI393 0062 2x115 1-3/8-10 2x18 389 12-14/17-19 2x24.7

UI393 0096 2x115 1-3/8-10 2x21 334 12-14/17-19 2x27.2

Yellow field are normaly in stock

Part NoPrimary Secondary

External fuse or PTC- resistance

(not included)

Vacuum castad PCB transformer with low profile design. Provided with mounting hole in the

corners. Dual primary and secondary windings (2x115V on prim.). The secondary windings can

be ether series or parallel connected. As overload protection use a PTC- resistance.

Series UI393 - 14VA

100% (All individuals)

Dual primary and secondary voltage 14VA ta70/F

50,0

57,3

UI39345,0

4x5,0

62,568,2

25,2

1 2 3 54 6 7 8 9

4x5,06,0

16 15141312 11

10

17181920

Prim

Sec

Soldering pin

0,6x0,8x4

Bottom view.

Equipped pins.

4 screwhole: dia 2.4mm on top and bottom.

Screw type: metalscrew 2.9x6.5mm.[mm]

www.flexitron.se 54/63

Page 55: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Primary voltage: 2×115 V~ ±10 % 50-60 Hz

Different voltage on inquiry.

Max primary current: 120 mA vid full last

Secondary voltage, rms 2x 6-24V~, ±5%

Power: 18 VA

Temperature class: ta70/B

Isolation: 4kV/10mm/classII

Standard: EN 61558

Approvals: ENEC (Europe)

UL/CSA (USA, Canada)

Overload protection:

Test:

Weight: 390 g

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

UI394 0086 2x115 1-3/8-10 2x6 1500 12-14/17-19 2x8.7

UI394 0110 2x115 1-3/8-10 2x7.5 1200 12-14/17-19 2x10.2

UI394 0063 2x115 1-3/8-10 2x9 1000 12-14/17-19 2x13.0

UI394 0087 2x115 1-3/8-10 2x12 750 12-14/17-19 2x16.7

UI394 0088 2x115 1-3/8-10 2x15 600 12-14/17-19 2x20.4

UI394 0075 2x115 1-3/8-10 2x18 500 12-14/17-19 2x23.6

UI394 0061 2x120 1-3/8-10 2x12 750 12-14/17-19 2x16.7

Yellow field are normaly in stock

Vacuum castad PCB transformer with low profile design. Provided with mounting hole in the

corners. Dual primary and secondary windings (2x115V on prim.). The secondary windings can

be ether series or parallel connected. As overload protection use a PTC- resistance.

Series UI394 - 18VA

100% (All individuals)

Dual primary and secondary voltage 18VA ta70/F

Part NoPrimary Secondary

External fuse or PTC- resistance

(not included)

50,0

57,3

UI39445,0

4x5,0

62,5

28,5

1 2 3 54 6 7 8 9

4x5,06,0

16 15141312 11

10

17181920

Prim

Sec

68,2

Soldering pin

0,6x0,8x4

Bottom view.

Equipped pins.

4 screwhole: dia 2.4mm on top and bottom.Screw type: metalscrew 2.9x6.5mm.[mm]

www.flexitron.se 55/63

Page 56: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Primary voltage: 2×115 V~ ±10 % 50-60 Hz

Different voltage on inquiry.

Max primary current: 160 mA at full load.

Secondary voltage, rms 2x 6-24V~, ±5%

Power: 24 VA

Temperature class: ta70/B

Isolation: 4kV/10mm/classII

Standard: EN 61558

Approvals: ENEC (Europe)

UL/CSA (USA, Canada)

Overload protection:

Test: 100% (Alla individer)

Weight: 460 g

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

UI395 0089 2x115 1-3/8-10 2x6 2000 12-14/17-19 2x7.8

UI395 0098 2x115 1-3/8-10 2x9 1333 12-14/17-19 2x11.4

UI395 0091 2x115 1-3/8-10 2x12 1000 12-14/17-19 2x14.9

UI395 0083 2x115 1-3/8-10 2x15 800 12-14/17-19 2x18.5

UI395 0099 2x115 1-3/8-10 2x18 666 12-14/17-19 2x22.0

UI395 0100 2x115 1-3/8-10 2x21 571 12-14/17-19 2x25.0

Yellow field are normaly in stock

Extern säkring eller PTC (medföljer

ej)

Vacuum castad PCB transformer with low profile design. Provided with mounting hole in the

corners. Dual primary and secondary windings (2x115V on prim.). The secondary windings can

be ether series or parallel connected. As overload protection use a PTC- resistance.

Series UI395 - 24VA

Part No

Primary Secondary

Dual primary and secondary voltage 24VA ta70/F

50,0

57,3

UI39545,0

4x5,0

62,568,2

32,0

1 2 3 54 6 7 8 9

4x5,06,0

16 15141312 11

10

17181920

Prim

Sec

Soldering pin

0,6x0,8x4

Bottom view.

Equipped pins.

4 screwhole: dia 2.4mm on top and bottom.

Screw type: metalscrew 2.9x6.5mm.

[mm]

www.flexitron.se 56/63

Page 57: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Primary voltage: 2×115 V~ ±10 % 50-60 Hz

Different voltage on inquiry.

Max primary current: 195 mA at full load.

Secondary voltage, rms 2x 6-24V~, ±5%

Power: 30 VA

Temperature class: ta70/B

Isolation: 4kV/10mm/cklassII

Standard: EN 61558

Approvals: ENEC (Europe)

UL/CSA (USA, Canada)

Overload protection:

Test:

Weight: 550 g

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

UI396 0101 2x115 1-3/8-10 2x6 2500 12-14/17-19 2x8.1

UI396 0102 2x115 1-3/8-10 2x9 1666 12-14/17-19 2x11.3

UI396 0079 2x115 1-3/8-10 2x12 1250 12-14/17-19 2x15

UI396 0103 2x115 1-3/8-10 2x15 1000 12-14/17-19 2x18.6

UI396 0080 2x115 1-3/8-10 2x18 833 12-14/17-19 2x22.3

UI396 0084 2x115 1-3/8-10 2x21 715 12-14/17-19 2x24.9

Yellow field are normaly in stock

Part NoPrimary Secondary

External fuse or PTC- resistance

(not included)

Vacuum castad PCB transformer with low profile design. Provided with mounting hole in the

corners. Dual primary and secondary windings (2x115V on prim.). The secondary windings can

be ether series or parallel connected. As overload protection use a PTC- resistance.

Series UI396 - 30VA

100% (All individuals)

Dual primary and secondary voltage 30VA ta70/F

50,0

57,3

UI39645,0

4x5,0

62,568,2

36,0

1 2 3 54 6 7 8 9

4x5,06,0

16 15141312 11

10

17181920

Prim

Sec

Soldering pin

0,6x0,8x4

Bottom view.

Equipped pins.

4 screwhole: dia 2.4mm on top and bottom.

Screw type: metalscrew 2.9x6.5mm.[mm]

www.flexitron.se 57/63

Page 58: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Primary voltage: 2×115 V~ ±10 % 50-60 Hz

Different voltage on inquiry.

Max primary current: 230 mA at full load.

Secondary voltage, rms 2x 6-21V~, ±5%

Power: 40 VA

Temperature class: ta70/B

Isolation: 4kV/10mm/classII

Standard: EN 61558

Approvals: ENEC (Europe)

UL/CSA (USA, Canada)

Overload protection:

Test:

Weight: 770 g

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

UI481 0001 2x 115 1-4/9-12 2x 6 3333 14-17/20-23 2x 7.3

UI481 0002 2x 115 1-4/9-12 2x 9 2222 14-17/20-23 2x 10.8

UI481 0003 2x 115 1-4/9-12 2x 12 1666 14-17/20-23 2x 14.3

UI481 0004 2x 115 1-4/9-12 2x 15 1333 14-17/20-23 2x 17.7

UI481 0005 2x 115 1-4/9-12 2x 18 1111 14-17/20-23 2x 21.7

UI481 0006 2x 115 1-4/9-12 2x 21 952 14-17/20-23 2x 25.2

Yellow field are normaly in stock

Part NoPrimary Secondary

Dual primary and secondary voltage 40VA ta70/F

External fuse or PTC- resistance

(not included)

Vacuum castad PCB transformer with low profile design. Provided with mounting hole in the

corners. Dual primary and secondary windings (2x115V on prim.). The secondary windings can

be ether series or parallel connected. As overload protection use a PTC- resistance.

Series UI481 - 40VA

100% (All individuals)

60,0

70,6

52,5

75,0

47,6Bottom view Equipped pins

Prim

Sec

Mounting hole dia 3,3 mm

UI482

1 2 3 4 5 6 7 8 9 121110

1615 14131718192021222324

3,55x5,0 5x5,07,0

83,7

Soldering pin

0,5x1,2x5

[mm]

www.flexitron.se 58/63

Page 59: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Primary voltage: 2×115 V~ ±10 % 50-60 Hz

Different voltage on inquiry.

Max primary current: 350 mA at full load.

Secondary voltage, rms 2x 6-21V~, ±5%

Power: 60 VA

Temperature class: ta70/B

Isolation: 4kV/10mm/cklassII

Standard: EN 61558

Approvals: ENEC (Europe)

UL/CSA (USA, Canada)

Overload protection:

Test:

Weight: 1090 g

Voltage Pins VoltageMax current

[mA]Pins

No load

voltage

UI482 0007 2x 115 1-4/9-12 2x6 5000 14-17/20-23 2x7.3

UI482 0008 2x 115 1-4/9-12 2x9 3333 14-17/20-23 2x10.5

UI482 0009 2x 115 1-4/9-12 2x12 2500 14-17/20-23 2x14.0

UI482 0010 2x 115 1-4/9-12 2x15 2000 14-17/20-23 2x17.5

UI482 0032 2x 115 1-4/9-12 2x16 1875 14-17/20-23 2x18.1

UI482 0011 2x 115 1-4/9-12 2x18 1666 14-17/20-23 2x21.1

UI482 0012 2x 115 1-4/9-12 2x21 1428 14-17/20-23 2x24.5

Dual primary and secondary voltage 60VA ta70/F

External fuse or PTC- resistance

(not included)

Vacuum castad PCB transformer with low profile design. Provided with mounting hole in the

corners. Dual primary and secondary windings (2x115V on prim.). The secondary windings can

be ether series or parallel connected. As overload protection use a PTC- resistance.

Series UI482 - 60VA

100% (All individuals)

Yellow field are normaly in stock

Part No

Primary Secondary

60,0

70,6

52,5

75,0

38,6

Prim

Sec

UI481

1 2 3 4 5 6 7 8 9 121110

1615 14131718192021222324

3,55x5,0 5x5,07,0

83,7

Bottom view Equipped pins

Mounting hole

dia 3,3 mm

Soldering pin

0,5x1,2x5

[mm]

www.flexitron.se 59/63

Page 60: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

CALCULATION EXAMPLE The calculations example below should be considered as approximations and serve as a guide to specify the transformers URMS and IRMS. In all formulas we have taking consideration to a ripple of maximum 2VP-P. Further we have provided that the capacitance of the capacitor “CL” is 3000µF per A load current for circuit 1 to 3, and 8000µF per A load current for circuit 4. As will be seen from the formulas below, circuit 1 is far more efficient than the

remaining circuits.

Circuit 1. Full wave rectifier

aeff

a

eff

II

UU

*75.1

2

3

=

+=

Circuit 2. Full wave rectifier with dual voltage

( )

( )

3)ciruit refer to(3.10

1)ciruit refer to(75.11II Load

:note

*45.03.1

2

2

a2a1

211

1

2

21

aeff

aeff

aaa

a

a

eff

aaa

a

eff

II

II

windingPerIIII

II

UUUU

U

=⇒=

=⇒=

+=

==+

=

The formula gives a linear transfer from circuit 1 to circuit 3.

effI

effU

aI

LC

aU

effI

LC

effU1aI

1aUeffU

LC

2aI 2aU

www.flexitron.se 60/63

Page 61: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Example 1.

Example 2.

Circuit 3. Full wave rectifier with centre couple transformer.

windingperII

UU

aeff

a

eff

*3.1

2

2

=

+=

( ) VAIIUP

mAI

VVU

WIUIUP

mAImAIVU

effeffeff

eff

eff

aaaatot

aaa

61.22 winding1 winding*

winding8710*60*10*60

10*2045.03.1

1585.142

219

52.1**

206019

3

3

3

21

21

=+=⇒

=

+=

≈=+

=

=+=

⇒===

( ) 2.1VA2 windingI1 windingI*

27010*40*10*40

10*4045.03.1

17010*40*10*40

10*4045.03.1

1585.142

219

52.1**

4019

effeff

3

3

3

3

3

3

21

21

=+==>

=

+=

=

+=

≈=+

=

=+=

⇒===

eff

eff

eff

eff

aaaatot

aaa

UP

windingmAI

windingmAI

VVU

WIUIUP

mAIIVU

effI aI

effU

effU

LC

aU

www.flexitron.se 61/63

Page 62: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

Circuit 4. Half wave rectifier

aeff

a

eff

II

UU

*2.3

2

2

=

+=

Calculation of the capacitor CL

r

a

U

ItC

*=

t= time in sec between the electrostatic induction. 5-7 ms at 50 Hz full wave. 15-17 ms at 50 Hz half wave. Ia = Load current [A]. Ur=Peak to peak over the capacitor. The ripple durability must be at leas 1.35 Ia.

A more accurate calculation of Ueff.

Reg.

VVU

Example

UUUU

U

UU

eff

drreganom

eff

1576.142

225.212

195

220

2

min

min

min

≈=+++

=

+++=

effU

effI aI

aU

LC

dU

effUnomU PPrU −

aU

regU

www.flexitron.se 62/63

Page 63: POWER TRANSFORMERS - JustAnswer€¦ · 09.03.2013 · POWER TRANSFORMERS Hahn, Germany Hahn is one of Europe’s leading manufacturer of vacuumed casted transformers in the power

KOMPONENTER

Flexitron AB • PO Box 7117 • Tumstocksvägen 11A • SE-187 12 TÄBY • Sweden

Phone +46 8 732 85 60 • Fax +46 8 756 91 32 • www.flexitron.se www.flexitron.se 63/63