Power Generation Industry applications

3
POWER 1 APPLICATIONS FOR BRIT-LUBES’ LUBRICANTS IN THE POWER GENERATION INDUSTRY The lubricant recommendations listed below provide details of the most cost effective products. Coal Handling Equipment Bunker Tripper All Bearings Load-Guard Coal Conveyors Conveyor Bearings Multi-Tef Grease MP2/3 Coal Crushers Grease Feed Bearings Multi-Tef Grease MP2/3 Coal Screens Vibrator Eccentrics Vibration Resistant Grease 2.5 Left is a generating station coal handler opening doors under a coal wagon. The coal falls into a large hopper and then onto a conveyor belt, right, that transports the coal to storage or directly to the main boiler. Coal fired power stations can burn more than 1000 tonnes of coal per day. The coal is transferred to the crushers before being conveyed to the main boilers.

description

Application of Brit-Lube's products in the Power Industry Generation Industry.

Transcript of Power Generation Industry applications

Page 1: Power Generation Industry applications

POWER

1

APPLICATIONS FOR BRIT-LUBES’ LUBRICANTS IN THE POWER

GENERATION INDUSTRY

The lubricant recommendations listed below provide details of the most cost effective products.

Coal Handling Equipment

Bunker Tripper All Bearings Load-Guard

Coal Conveyors Conveyor Bearings Multi-Tef Grease MP2/3

Coal Crushers Grease Feed Bearings Multi-Tef Grease MP2/3

Coal Screens Vibrator Eccentrics Vibration Resistant Grease 2.5

Left is a generating station

coal handler opening doors under a coal wagon. The coal falls into a large hopper and

then onto a conveyor belt, right, that transports the coal to storage or directly to the

main boiler. Coal fired power stations can burn more than 1000 tonnes of coal per day.

The coal is transferred to the crushers before being conveyed to the main boilers.

Page 2: Power Generation Industry applications

POWER

2

Coal Feeder Delivery Equipment

Main Bearings Multi-Tef Grease MP2/3

Bush bearings Pretreat with Assembly Grease

Multi-Tef Grease MP2/3as service lubricant

Boiler Room

Boilers and Associated Equipment Mechanical Stokers Multi-Tef Grease MP2/3

Damper Flue Inlet Bearings Synthetic HT2

Flue Fan Bearings Bearings Synthetic HT2

Boiler Valve Lubrication All Valves Silicone Valve Seal

Handwheels Synthetic HT2

Butterfly Valves Bush bearings Assembly Grease

Soot Blowers (Hopkinson) Motor Bearings Multi-Tef Grease MP2/3

Trip Levers Multi-Tef Grease MP2/3

Travelling Gearbox Multi-Tef Grease MP2/3

Jockey Sprocket Bearing Multi-Tef Grease MP2/3

Front Support Rollers Multi-Tef Grease MP2/3

Ash Conveyors Support Plates Multi-Tef Grease MP2/3

Hopper Scroll and Follower Multi-Tef Grease MP2/3

Sump Pumps All Bearings Multi-Tef Grease MP2/3

Vibrator Feeders Hopper Doors and Bearings Multi-Tef Grease MP2/3

Boom Stacker Bearings Multi-Tef Grease MP2/3

Adjustment Block & Slides Multi-Tef Grease MP2/3

Ground Hoppers Bearings Multi-Tef Grease MP2/3

Coolers

Fans Bearings Load-Guard

Pumps Bearings Load-Guard

Butterfly Valve

Coal is transported into the plant by way of five different conveyors. Before it enters the plant, the coal is tested for heat value, sulphur content and other

qualities and is crushed further. Any pieces of iron in the coal are also separated. The coal is stored in large bunkers before passing through coal feeders that

measure the amount of coal needed to make

Soot Blowers are used for boiler maintenance

Page 3: Power Generation Industry applications

POWER

3

Generation Room

Circuit Breakers Gearboxes Brit-Gear Oils

Switchgear Bearings and Gears Multi-Tef Grease MP2/3

Jack Screws Multi-Tef Grease MP2/3

On Load Tap Changes Bearings and Gears Load-Guard

Cold Water Pumps Bearings Aqua-Guard

Make-up Pumps Bearings Multi-Tef Grease MP2/3

Air Blast Circuit Breakers ChemTef 2

Circuit Breakers Tripping Mechanisms Multi-Lube

Other

Dust Pumps Bearings Load-Guard

Conveyors Bearings Load-Guard

Acid Plant Valve Stem Lubrication Chemtef 2

The foregoing information is given in good faith but without warranty

Steam enters the turbine from the main boiler at 124 bar (1,800 psi) and at 540ºC (1000ºF).

Turbine and generator turn at 3,600 rpm generating 100 megawatts of electricity. (Enough power to illuminate one million 100 watt light bulbs).