1 LIEBERT ® INTELLISLOT ® 485 CARDS Product Specification/Installation Sheet Description Liebert IntelliSlot 485 cards provides Liebert SiteScan ® Web or Building Management Systems monitoring and control of your Liebert equipment. The card delivers Modbus or the Emerson Protocol via the RS-485 port. Liebert IntelliSlot 485 Card Liebert IntelliSlot 485 Card-S Liebert IntelliSlot 485 Card-LBDS Liebert IntelliSlot 485 Card-X Liebert IntelliSlot 485 Card-L Compatibility With Other Emerson Network Power Products The Liebert IntelliSlot 485 Card family, formerly the Liebert OpenComms line, includes: Liebert IntelliSlot Card Part Number Compatible with: Liebert IntelliSlot 485 Card OC-485 • Liebert GXT • Liebert GXT 6kVA&10kVA • Liebert GXT3 • Liebert GXT2U • Liebert Hinet • Liebert Nfinity ® • Liebert NX • Liebert PowerSure PSI (before July 2008) Liebert IntelliSlot 485 Card-LBDS OC485-LBDS Units with Liebert iCOM ® Firmware prior to PA1.04.033.STD: • Liebert Challenger 3000 • Liebert Challenger ITR • Liebert CW • Liebert Deluxe System/3 • Liebert DS • Liebert PeX • Liebert XDC with Liebert iCOM • Liebert XDF Liebert IntelliSlot 485 Card-L IS-485L • Liebert APM • Liebert CRV • Liebert HPC • Liebert HPM • Liebert XDP with Liebert iCOM Units with Liebert iCOM Firmware PA1.04.033.STD or later: • Liebert Challenger 3000 • Liebert Challenger ITR • Liebert CW • Liebert Deluxe System/3 • Liebert DS • Liebert PeX • Liebert XDC with Liebert iCOM Liebert IntelliSlot 485 Card-S IS-485S Units with Liebert IntelliSlot support only: • Liebert FDC • Liebert FPC • Liebert PPC • Liebert RDC • Liebert RX Liebert IntelliSlot 485 Card-X IS-485X • Liebert NXL (SA, SR, SN, MM, CD), Alber ® BDSU Liebert IntelliSlot Card Communication Protocols The 485 cards support the following protocols: Liebert IntelliSlot Card Part Number Communication Protocol MODBUS/485 IGM Liebert IntelliSlot 485 Card OC-485 Liebert IntelliSlot 485 Card-LBDS OC485-LBDS Liebert IntelliSlot 485 Card-L IS-485L Liebert IntelliSlot 485 Card-S IS-485S Liebert IntelliSlot 485 Card-X IS-485X DTE/DB9F serial port for configuration (requires null-modem connection) RS-485 (for Modbus) OR RS-422 (for IGM) Depends on configuration by user

description

Manual Placa

Transcript of Placa Up Ste Cub

  • 1LIEBERT INTELLISLOT 485 CARDS

    Product Specification/Installation SheetDescriptionLiebert IntelliSlot 485 cards provides Liebert SiteScan Web or Building Management Systems monitoring and control of your Liebert equipment.

    The card delivers Modbus or the Emerson Protocol via the RS-485 port.

    Liebert IntelliSlot 485 Card Liebert IntelliSlot 485 Card-SLiebert IntelliSlot 485 Card-LBDS Liebert IntelliSlot 485 Card-XLiebert IntelliSlot 485 Card-L

    Compatibility With Other Emerson Network Power ProductsThe Liebert IntelliSlot 485 Card family, formerly the Liebert OpenComms line, includes:

    Liebert IntelliSlot Card Part Number Compatible with:

    Liebert IntelliSlot 485 Card OC-485 Liebert GXT Liebert GXT 6kVA&10kVA Liebert GXT3

    Liebert GXT2U Liebert Hinet Liebert Nfinity

    Liebert NX Liebert PowerSure PSI

    (before July 2008)

    Liebert IntelliSlot 485 Card-LBDS OC485-LBDS

    Units with Liebert iCOM Firmware prior to PA1.04.033.STD: Liebert Challenger 3000 Liebert Challenger ITR Liebert CW

    Liebert Deluxe System/3

    Liebert DS

    Liebert PeX Liebert XDC with

    Liebert iCOM Liebert XDF

    Liebert IntelliSlot 485 Card-L IS-485L

    Liebert APM Liebert CRV

    Liebert HPC Liebert HPM

    Liebert XDP withLiebert iCOM

    Units with Liebert iCOM Firmware PA1.04.033.STD or later: Liebert Challenger 3000 Liebert Challenger ITR Liebert CW

    Liebert Deluxe System/3

    Liebert DS

    Liebert PeX Liebert XDC with

    Liebert iCOM

    Liebert IntelliSlot 485 Card-S IS-485SUnits with Liebert IntelliSlot support only: Liebert FDC Liebert FPC

    Liebert PPC Liebert RDC

    Liebert RX

    Liebert IntelliSlot 485 Card-X IS-485X Liebert NXL (SA, SR, SN, MM, CD), Alber BDSU

    Liebert IntelliSlot Card Communication ProtocolsThe 485 cards support the following protocols:

    Liebert IntelliSlot Card Part Number

    Communication Protocol

    MODBUS/485 IGM

    Liebert IntelliSlot 485 Card OC-485 Liebert IntelliSlot 485 Card-LBDS OC485-LBDS Liebert IntelliSlot 485 Card-L IS-485L Liebert IntelliSlot 485 Card-S IS-485S Liebert IntelliSlot 485 Card-X IS-485X

    DTE/DB9F serial port for configuration (requires null-modem connection)

    RS-485 (for Modbus)

    ORRS-422 (for IGM)Depends on configuration by user

  • 2 2007 Liebert CorporationAll rights reserved throughout the world. Specifications subject to change without notice.

    Liebert is a registered trademark of Liebert Corporation. All names referred to are trademarks or registered trademarks of their respective owners.

    SL-28160_REV8_08-13

    Liebert Corporation1050 Dearborn DriveP.O. Box 29186Columbus, OH 43229

    Telephone: 1-800-877-9222Facsimile: 1-614-841-6022www.liebert.com

    Wiring Specifications

    Dimensions

    Specifications

    Connection Supported Wire Type Max. Wire Length

    RS-422 (IGM) 18-22 AWG Stranded & Shielded18 AWG recommendedNon Plenum - Belden 9461Plenum - Belden 88761 1000 ft. (300m)

    RS-485 (Modbus) 18-22 AWG Stranded & Shielded18 AWG recommendedNon Plenum - Belden 9461Plenum - Belden 88761 3000 ft. (915m)

    RS-232DB-9F Connector

    Null Modem CableDTE Null Modem Cable

    Null Modem CableDTE Null Modem Cable 50 ft. (15.3m)

    Power Requirements

    AC Inputs 18 - 24 VAC; 50/60 HzDC Inputs 12 - 36VDCPower Consumption 6VA maximum (1.75W)

    Dimensions - W x D x H: in. (mm) 3 x 5-1/4 x 1-1/2 (76 x 134 x 38)

    WeightNet - oz. (kg) 7 (0.2)Shipping - lb. (kg) 1.3 (0.6)

    Ambient Operating Environment, F (C) 32 to 104 (0 to 40); 10% to 90% RH (non-condensing)Ambient Storage Temperature, F (C) -4 to 140 (-20 to 60)Protection SELV Isolated User Connections, Watchdog Timer Circuitry

    CommunicationPorts

    Service Terminal (RS-232) DB9F, DTEModbus (RS-485) 2-Position Terminal BlockIGM (RS-422) 2-Position Terminal Block

    RS485 RS232

    - +

    2-3/8"(60.3mm)

    4-3/4"(121mm)

    RS-232 port

    1/2" (11mm)

    1-1/2"(38mm)

    3"(76mm)

    FaceplateTOP VIEW

    FRONT VIEW

    DescriptionCompatibility With Other Emerson Network Power ProductsLiebert IntelliSlot Card Communication ProtocolsWiring SpecificationsDimensionsSpecifications