Photo: HELUKABEL Copper Data Cables HELUKAT · Copper Data Cables HELUKAT ... They can be used to...

34
R 52 ® Copper Data Cables HELUKAT ® All HELUKAT ® data cables and wires comply with the latest standardisation recommendations and are designed for use in high-speed networks with transmission rates of 100Mbit/s and higher (e.g. CCDI, TPDDI, ATM, SDH/SONET). All HELUKAT® types of cables and wires meet the requirements of category 5 according to EIA/TIA TSB-36 ISO/IEC DIS 11801, CENELEC pr EN 50173, as well as category 6/7 according to DIN 44312-5/ EN 50288. Cables for Ethernet applications, as well as coax/twinaxial cables cables for IBMs IVS system complete the product range from HELUKABEL ® . The excellent transmission characteristics of HELUKAT ® data cables and wires constitute enormous challenges for production equipment and the measurement laboratories. HELUKAT ® data cables and wires are manufactured using the latest machinery technologies. These have been designed for producing cables and wires of the categories 5/6/7/8 in accordance with the latest standardisation recommendations. A special laboratory for high-frequency testing such high transmission rates has been installed complete with network analyser and computer-controlled equipment for HF cables. Photo: HELUKABEL R

Transcript of Photo: HELUKABEL Copper Data Cables HELUKAT · Copper Data Cables HELUKAT ... They can be used to...

R 52

®

Copper Data Cables HELUKAT®

All HELUKAT® data cables and wires comply with the latest standardisation recommendations and are designed for use in high-speednetworks with transmission rates of 100Mbit/s and higher (e.g. CCDI, TPDDI, ATM, SDH/SONET). All HELUKAT® types of cables andwires meet the requirements of category 5 according to EIA/TIA TSB-36 ISO/IEC DIS 11801, CENELEC pr EN 50173, as well as category6/7 according to DIN 44312-5/ EN 50288. Cables for Ethernet applications, as well as coax/twinaxial cables cables for IBMs IVS systemcomplete the product range from HELUKABEL®.The excellent transmission characteristics of HELUKAT® data cables and wires constitute enormous challenges for productionequipment and the measurement laboratories. HELUKAT® data cables and wires are manufactured using the latest machinerytechnologies. These have been designed for producing cables and wires of the categories 5/6/7/8 in accordance with the lateststandardisation recommendations. A special laboratory for high-frequency testing such high transmission rates has been installedcomplete with network analyser and computer-controlled equipment for HF cables.

Photo: HELUKABEL

R

R 53

Contents Copper Data Cables

HELUKAT® 155 UTP ............................................................................................................................................................ R 54

HELUKAT® 155 UTP UL ....................................................................................................................................................... R 55

HELUKAT® 300 UTP UL ....................................................................................................................................................... R 56

HELUKAT® 100 UTP flex ..................................................................................................................................................... R 57

HELUKAT® 155 FTP ............................................................................................................................................................. R 58

HELUKAT® 100 FTP flex ...................................................................................................................................................... R 59

HELUKAT® 100 FTP FE60 .................................................................................................................................................... R 60

HELUKAT® 200 FTP flex, UL ................................................................................................................................................ R 61

HELUKAT® 200 S-FTP. ......................................................................................................................................................... R 62

HELUKAT® 200 S-FTP duplex ............................................................................................................................................. R 63

HELUKAT® 200 S-FTP flex ................................................................................................................................................... R 64

HELUKAT® 300 U-STP, UL .................................................................................................................................................... R 65

HELUKAT® 450 S-STP .......................................................................................................................................................... R 66

HELUKAT® 450 S-STP duplex .............................................................................................................................................. R 67

HELUKAT® 500 F-STP .......................................................................................................................................................... R 68

HELUKAT® 500 F-FTP duplex ............................................................................................................................................. R 69

HELUKAT® 500 F-FTP, flex .................................................................................................................................................. R 70

HELUKAT® 600 S-STP .......................................................................................................................................................... R 71

HELUKAT® 600 S-STP duplex .............................................................................................................................................. R 72

HELUKAT® 600 S-STP flex ................................................................................................................................................... R 73

HELUKAT® 600A S-STP PVC/PVC ........................................................................................................................................ R 74

HELUKAT® 600E S-STP PVC ................................................................................................................................................ R 75

HELUKAT® 600AE S-STP FRNC/PE ...................................................................................................................................... R 76

HELUKAT® 1200 S-STP ........................................................................................................................................................ R 77

HELUKAT® 1200 S-STP duplex ............................................................................................................................................ R 78

HELUKAT® 1200 S-STP ........................................................................................................................................................ R 79

HELUKAT® 1200 S-STP duplex ............................................................................................................................................ R 80

HELUKAT® 1500 S-STP, Multimedia .................................................................................................................................... R 81

HELUKAT® 1500 S-STP duplex, Multimedia ....................................................................................................................... R 82

TWINAX LAN-Cable IBM P/N 7 362 211 ............................................................................................................................. R 83

IVS LAN-Cable IBM type 1A, type 1A mini, Typ 6A ............................................................................................................ R 84

Cheapernet Cable, Yellow Cable, Transceiver Cable ......................................................................................................... R 85

Description Page

155LAN CableCategory 5e

UTP

UTP 4x2xAWG 24/1 PVCCable structure0,51 mmInner conductor diameter:Copper, bareConductor material:PECore insulation:whbu/bu, whog/og, whgn/gn, whbn/bnCore colours:-Shielding 1:-Screen over stranding element:-Screen 1 over stranding:-Screen 2 over stranding:PVCOuter sheath material:approx. 4,9 mmOuter diameter:GreyOuter sheath colour:

Electrical data100 Ohm ± 15 ohm at 1 to 100 MHzCharacteristic impedance:190 Ohm/km max.Loop resistance:50 nF/km nom.Mutual capacitance:66 %Rel. propagation velocity:

Typical values15510062,51610(MHz)Frequency26,821,316,58,06,3(dB/100m)Attenuation33,035,338,447,350,3(db)Next6,214,021,939,344,0(db)ACR

Technical dataapprox. 26 kg/kmWeight:40 mmMin. bending radius for laying:-20°COperating temperature range min.:+60°COperating temperature range max.:0,40 MJ/mCaloric load, approx. value:17,00 kg/kmCopper weight:

NormsAcc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5e

ApplicationHELUKAT®155 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performancereserves and outstanding performance. They can be used to implement services such as Fast Ethernet, Ethernet, ATM155, FDDI, token ring4/16 Mbit/s, or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application in tight cablechannels and platforms due to their optimized construction.

80053, UTP 4x2xAWG24/1 PVC (U/UTP)Part no.Dimensions and specifications may be changed without prior notice.

R 54

R

155LAN CableCategory 5e

UTP UL

UTP 4x2xAWG 24/1 PVC, ULCable structure0,53 mmInner conductor diameter:Copper, bareConductor material:PECore insulation:whbu/bu, whog/og, whgn/gn, whbn/bnCore colours:-Shielding 1:-Screen over stranding element:-Screen 1 over stranding:-Screen 2 over stranding:PVCOuter sheath material:approx. 5,2 mmOuter diameter:GreyOuter sheath colour:

Electrical data100 Ohm ± 15 ohm at 1 to 100 MHzCharacteristic impedance:190 Ohm/km max.Loop resistance:50 nF/km nom.Mutual capacitance:66 %Rel. propagation velocity:

Typical values15510062,51610(MHz)Frequency22,719,915,27,76,1(db/100m)Attenuation37,040,053,063,065,0(db)Next14,320,137,855,358,9(db)ACR

Technical dataapprox. 35 kg/kmWeight:42 mmMin. bending radius for laying:-20°COperating temperature range min.:+60°COperating temperature range max.:0,43 MJ/mCaloric load, approx. value:17,00 kg/kmCopper weight:

NormsAcc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5e,Flame-retardant acc. to IEC 60332-1, Smoke density acc. to IEC 61034, CMX 444

ApplicationHELUKAT®155 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performancereserves and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155,FDDI, token ring 4/16 Mbit/s, or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the applicationin tight cable channels and platforms due to their optimized construction. This type is certified according UL because of the special PVCjacket.

802171, UTP 4x2xAWG24/1 PVC UL (U/UTP)Part no.Dimensions and specifications may be changed without prior notice.

R 55

300LAN CableCategory 6

UTP UL

UTP 4x2xAWG 24/1 PVC, ULCable structure0,55 mmInner conductor diameter:Copper, bareConductor material:PECore insulation:whbu/bu, whog/og, whgn/gn, whbn/bnCore colours:-Shielding 1:-Screen over stranding element:-Screen 1 over stranding:-Screen 2 over stranding:PVCOuter sheath material:approx. 6,8 mmOuter diameter:GreyOuter sheath colour:

Electrical data100 Ohm ± 20 ohm at 101 to 155 MHzCharacteristic impedance:190 Ohm/km max.Loop resistance:50 nF/km nom.Mutual capacitance:67 %Rel. propagation velocity:

Typical values30020015510062,51610(MHz)Frequency32,526,022,918,214,37,05,6(db/100m)Attenuation55,057,060,063,065,070,072,0(db)Next22,531,037,144,850,763,066,4(db)ACR

Technical dataapprox. 46 kg/kmWeight:55 mmMin. bending radius for laying:-20°COperating temperature range min.:+60°COperating temperature range max.:0,68 MJ/mCaloric load, approx. value:20,00 kg/kmCopper weight:

NormsAcc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 6, Flame-retardant acc.to IEC 60332-1, Smoke density acc. to IEC 61034, CMX 444

ApplicationHELUKAT®300 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performancereserves and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155,FDDI, token ring 4/16 Mbit/s, or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the applicationin tight cable channels and platforms due to their optimized construction. This type is certified according UL because of the special PVCjacket.

802172, UTP 4x2xAWG24/1 PVC UL (U/UTP)Part no.Dimensions and specifications may be changed without prior notice.

R 56

R

100LAN-CableCategory 5

UTP flex

UTP 4x2xAWG 26/7 PVCCable structure0,48 mmInner conductor diameter:Copper, bareConductor material:POCore insulation:whbu/bu, whog/og, whgn/gn, whbn/bnCore colours:-Shielding 1:-Screen over stranding element:-Screen 1 over stranding:-Screen 2 over stranding:PVCOuter sheath material:approx. 4,5 mmOuter diameter:Grey similar to RAL 7035Outer sheath colour:

Electrical data100 Ohm ± 15 ohm at 1 to 100 MHzCharacteristic impedance:290 Ohm/km max.Loop resistance:50 nF/km nom.Mutual capacitance:74 %Rel. propagation velocity:

Typical values10062,51610(MHz)Frequency3,12,41,20,9(dB/10m)Attenuation38,041,050,053,0(db)Next34,938,648,852,1(db)ACR

Technical dataapprox. 17 kg/kmWeight:35 mmMin. bending radius for laying:-20°COperating temperature range min.:+60°COperating temperature range max.:0,527 MJ/mCaloric load, approx. value:11,00 kg/kmCopper weight:

NormsAcc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5

ApplicationHELUKAT®100 data cables are used in the tertiary level of a network as patch cables and connection cables. They are characterized by largeperformance reserves and outstanding performance. They can be used to implement services such as Fast Ethernet, Ethernet, ATM155,FDDI, token ring 4/16 Mbit/s, or ISDN absolutely trouble-free. With its optimized construction, the HELUKAT®100 series can be manufacturedquickly and easily with all common RJ45 plugs.

80055, UTP 4x2xAWG 26/7 PVC (U/UTP)Part no.Dimensions and specifications may be changed without prior notice.

R 57

155LAN CableCategory 5e

FTP

FTP 4x2xAWG 24/1 PVCCable structure0,51 mmInner conductor diameter:Copper, bareConductor material:PECore insulation:whbu/bu, whog/og, whgn/gn, whbn/bnCore colours:Polyester foil over stranded bundleShielding 1:-Screen over stranding element:Polyester foil, aluminium-linedScreen 1 over stranding:-Screen 2 over stranding:PVCOuter sheath material:approx. 5,9 mmOuter diameter:Yellow similar to RAL 1021Outer sheath colour:

Electrical data100 Ohm ± 15 ohm at 1 to 100 MHzCharacteristic impedance:170 Ohm/km max.Loop resistance:50 nF/km nom.Mutual capacitance:69 %Rel. propagation velocity:

Typical values15510062,51610(MHz)Frequency22,020,315,77,65,9(dB/100m)Attenuation40,040,044,053,059,0(db)Next18,019,728,345,453,1(db)ACR

Technical dataapprox. 40 kg/kmWeight:48 mmMin. bending radius for laying:-20°COperating temperature range min.:+60°COperating temperature range max.:0,40 MJ/mCaloric load, approx. value:18,00 kg/kmCopper weight:

NormsAcc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5e

ApplicationHELUKAT®155 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performancereserves and outstanding performance. They can be used to implement services such as Fast Ethernet, Ethernet, ATM155, FDDI, token ring4/16 Mbit/s, or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application in tight cablechannels and platforms due to their optimized construction.

80043, FTP 4x2xAWG24/1 PVC (F/UTP)Part no.Dimensions and specifications may be changed without prior notice.

R 58

R

100LAN CableCategory 5

FTP flex

FTP 4x2xAWG 26/7 FRNCCable structure0,48 mmInner conductor diameter:Copper, bareConductor material:POCore insulation:whbu/bu, whog/og, whgn/gn, whbn/bnCore colours:Polyester foil over stranded bundleShielding 1:-Screen over stranding element:Polyester foil, aluminium-linedScreen 1 over stranding:-Screen 2 over stranding:FRNCOuter sheath material:approx. 5,7 mmOuter diameter:Grey similar to RAL 7035Outer sheath colour:

Electrical data100 Ohm ± 15 ohm at 1 to 100 MHzCharacteristic impedance:290 Ohm/km max.Loop resistance:50 nF/km nom.Mutual capacitance:74 %Rel. propagation velocity:

Typical values10062,51610(MHz)Frequency2,92,41,20,9(dB/10m)Attenuation43,045,056,058,0(db)Next40,142,654,857,1(db)ACR

Technical dataapprox. 31 kg/kmWeight:40 mmMin. bending radius for laying:-20°COperating temperature range min.:+60°COperating temperature range max.:0,527 MJ/mCaloric load, approx. value:14,00 kg/kmCopper weight:

NormsAcc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5, Flame-retardant acc.to IEC 60332-1, Smoke density acc. to IEC 61034, Halogen-free acc. to 60754-2, Corrosivenessacc. to EN50267-2-3

ApplicationHELUKAT®100 data cables are used in the tertiary level of a network as patch cables and connection cables. They are characterized by largeperformance reserves and outstanding performance. They can be used to implement services such as Fast Ethernet, Ethernet, ATM155,FDDI, token ring 4/16 Mbit/s, or ISDN absolutely trouble-free. With its optimized construction, the HELUKAT®100 series can be manufacturedquickly and easily with all common RJ45 plugs.

81278, FTP 4x2xAWG 26/7 FRNC (F/UTP)Part no.Dimensions and specifications may be changed without prior notice.

R 59

100LAN CablesCategory 5

FTP FE60

F-FTP 4x2xAWG 24/1 FR-0HCable structure0,51 mmInner conductor diameter:Copper, bareConductor material:PE + flame resistant tapeCore insulation:whbu/bu, whog/og, whgn/gn, whbn/bnCore colours:Polyester foil over stranded bundleShielding 1:-Screen over stranding element:-Screen 1 over stranding:Polyester foil, aluminium-linedScreen 2 over stranding:LSZHOuter sheath material:approx. 8,3 mmOuter diameter:RedOuter sheath colour:

Electrical data100 Ohm ± 15 ohm at 1 to 100 MHzCharacteristic impedance:182 Ohm/km max.Loop resistance:53 nF/km nom.Mutual capacitance:67 %Rel. propagation velocity:

Typical values10062,51610(MHz)Frequency19,314,97,35,7(dB/100m)Attenuation38,042,053,056,0(db)Next18,727,145,750,3(db)ACR

Technical dataapprox. 90 kg/kmWeight:130 mmMin. bending radius for laying:-20°COperating temperature range min.:+70°COperating temperature range max.:0,91 MJ/mCaloric load, approx. value:24,00 kg/kmCopper weight:

NormsAcc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5, Flame-retardant acc.to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to 60754-2, Corrosivenessacc. to EN50267-2-3

ApplicationHELUKAT®100-FE60 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by largeperformance reserves and outstanding performance. They can be used to implement services such as Fast Ethernet, Ethernet, ATM155,FDDI, token ring 4/16 Mbit/s, or ISDN absolutely trouble-free. Likewise, the thermal characteristics are perfectly suited to realize an isolationintegrity according EN50200-FE60 due to their optimized construction.

804045, F-FTP 4x2xAWG 24/1 FR-0HPart no.Dimensions and specifications may be changed without prior notice.

R 60

R

200LAN CablesCategory 5e

FTP Flex, UL

FTP 4x2xAWG 26/7 PVC, ULCable structure0,48 mmInner conductor diameter:Copper, bareConductor material:PECore insulation:whbu/bu, whog/og, whgn/gn, whbn/bnCore colours:-Shielding 1:-Screen over stranding element:Polyester foil, aluminium-linedScreen 1 over stranding:-Screen 2 over stranding:PVCOuter sheath material:approx. 5,4 mmOuter diameter:Grey similar to RAL 7035Outer sheath colour:

Electrical data100 Ohm ± 20 ohm at 101 to 155 MHzCharacteristic impedance:290 Ohm/km max.Loop resistance:50 nF/km nom.Mutual capacitance:67 %Rel. propagation velocity:

Typical values20010062,51610(MHz)Frequency3,93,12,41,20,9(db/10m)Attenuation45,048,050,060,062,0(db)Next41,144,947,658,861,1(db)ACR

Technical dataapprox. 30 kg/kmWeight:44 mmMin. bending radius for laying:-20°COperating temperature range min.:+60°COperating temperature range max.:0,40 MJ/mCaloric load, approx. value:15,00 kg/kmCopper weight:

NormsAcc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5e,Flame-retardant acc. to IEC 60332-1, Smoke density acc. to IEC 61034, CMX 444

ApplicationHELUKAT®200 data cables are used in the tertiary level of a network as patch cables and connection cables. They are characterized by largeperformance reserves and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet,Ethernet, ATM155, FDDI, token ring 4/16 Mbit/s, or ISDN absolutely trouble-free. With its optimized construction, the HELUKAT®200 seriescan be manufactured quickly and easily with all common RJ45 plugs. This type is certified according UL because of the special PVC jacket.

802173, FTP 4x2xAWG26/7 PVC UL (F/UTP)Part no.Dimensions and specifications may be changed without prior notice.

R 61

200LAN-CableCategory 5e

S-FTP

S-FTP 4x2xAWG 24/1 PVC or FRNCCable structure0,51 mmInner conductor diameter:Copper, bareConductor material:Foam-skin-PECore insulation:whbu/bu, whog/og, whgn/gn, whbn/bnCore colours:Polyester foil over stranded bundleShielding 1:-Screen over stranding element:Polyester foil, aluminium-linedScreen 1 over stranding:Cu braidScreen 2 over stranding:PVC / FRNCOuter sheath material:approx. 6,0 mm / approx. 6,0 mmOuter diameter:Grey similar to RAL 7035Outer sheath colour:

Electrical data100 Ohm ± 15 ohm at 1 to 100 MHzCharacteristic impedance:185 Ohm/km max.Loop resistance:48 nF/km nom.Mutual capacitance:74 %Rel. propagation velocity:

Typical values20010062,51610(MHz)Frequency25,918,214,47,25,6(dB/100m)Attenuation40,046,050,059,062,0(db)Next14,627,835,651,856,4(db)ACR

Technical dataapprox. 50 kg/kmWeight:52 mmMin. bending radius for laying:-20°COperating temperature range min.:+60°COperating temperature range max.:0,60 MJ/m / 0,48 MJ/mCaloric load, approx. value:27,00 kg/kmCopper weight:

Norms81610:Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5e81609:Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5e, Flame-retardant:acc. to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to 60754-2,Corrosiveness acc. to EN50267-2-3

ApplicationHELUKAT®200 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performancereserves and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155,FDDI, token ring 4/16 Mbit/s, or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the applicationin tight cable channels and platforms due to their optimized construction.

81609, S-FTP 4x2xAWG 24/1 FRNC (SF/UTP)81610, S-FTP 4x2xAWG 24/1 PVC (SF/UTP)Part no.Dimensions and specifications may be changed without prior notice.

R 62

R

200LAN CableCategory 5e

S-FTP duplex

S-FTP 2x(4x2xAWG 24/1) FRNCCable structure0,51 mmInner conductor diameter:Copper, bareConductor material:Foam-skin-PECore insulation:whbu/bu, whog/og, whgn/gn, whbn/bnCore colours:Polyester foil over stranded bundleShielding 1:-Screen over stranding element:Polyester foil, aluminium-linedScreen 1 over stranding:Cu braidScreen 2 over stranding:FRNCOuter sheath material:approx. 6,0 mm x 12,5 mmCable dimensions:Green similar to RAL 6018Outer sheath colour:

Electrical data100 Ohm ± 15 ohm at 1 to 100 MHzCharacteristic impedance:185 Ohm/km max.Loop resistance:48 nF/km nom.Mutual capacitance:74 %Rel. propagation velocity:

Typical values20010062,51610(MHz)Frequency25,918,214,47,25,6(dB/100m)Attenuation40,046,050,059,062,0(db)Next14,627,835,651,856,4(db)ACR

Technical dataapprox. 100 kg/kmWeight:52 mmMin. bending radius for laying:-20°COperating temperature range min.:+60°COperating temperature range max.:0,96 MJ/mCaloric load, approx. value:54,00 kg/kmCopper weight:

NormsAcc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5e,Flame-retardant acc. to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to60754-2, Corrosiveness acc. to EN50267-2-3

ApplicationHELUKAT®200 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performancereserves and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155,FDDI, token ring 4/16 Mbit/s, or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the applicationin tight cable channels and platforms due to their optimized construction.

81123, S-FTP 2x(4x2xAWG 24/1) FRNC (SF/UTP)Part no.Dimensions and specifications may be changed without prior notice.

R 63

200LAN CableCategory 5e

S-FTP flex

S-FTP 4x2xAWG 26/7 FRNCCable structure0,48 mmInner conductor diameter:Copper, bareConductor material:POCore insulation:whbu/bu, whog/og, whgn/gn, whbn/bnCore colours:Polyester foil over stranded bundleShielding 1:-Screen over stranding element:Polyester foil, aluminium-linedScreen 1 over stranding:Cu braidScreen 2 over stranding:FRNCOuter sheath material:approx. 5,3 mmOuter diameter:Grey similar to RAL 7035Outer sheath colour:

Electrical data100 Ohm ± 15 ohm at 1 to 100 MHzCharacteristic impedance:260 Ohm/km max.Loop resistance:47 nF/km nom.Mutual capacitance:69 %Rel. propagation velocity:

Typical values20010062,51610(MHz)Frequency4,32,92,41,10,8(dB/10m)Attenuation37,043,045,056,058,0(db)Next32,740,142,654,957,2(db)ACR

Technical dataapprox. 35 kg/kmWeight:46 mmMin. bending radius for laying:-20°COperating temperature range min.:+60°COperating temperature range max.:0,543 MJ/mCaloric load, approx. value:24,00 kg/kmCopper weight:

NormsAcc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5e,Flame-retardant acc. to IEC 60332-1, Smoke density acc. to IEC 61034, Halogen-free acc. to60754-2, Corrosiveness acc. to EN50267-2-3

ApplicationHELUKAT®200 data cables are used in the tertiary level of a network as patch cables and connection cables. They are characterized by largeperformance reserves and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet,Ethernet, ATM155, FDDI, token ring 4/16 Mbit/s, or ISDN absolutely trouble-free. With its optimized construction, the HELUKAT®200 seriescan be manufactured quickly and easily with all common RJ45 plugs.

81254, S-FTP 4x2xAWG 26/7 FRNC (SF/UTP)Part no.Dimensions and specifications may be changed without prior notice.

R 64

R

300LAN CableCategory 6

U-STP, UL

S-UTP 4x2xAWG 26/7 PVC, ULCable structure0,48 mmInner conductor diameter:Copper, tinnedConductor material:Foam-skin-PECore insulation:whbu/bu, whog/og, whgn/gn, whbn/bnCore colours:Polyester foil over stranded bundleShielding 1:Polyester foil, aluminium-linedScreen over stranding element:-Screen 1 over stranding:-Screen 2 over stranding:PVCOuter sheath material:approx. 5,9 mmOuter diameter:Grey similar to RAL 7035Outer sheath colour:

Electrical data100 Ohm ± 20 ohm at 101 to 155 MHzCharacteristic impedance:290 Ohm/km max.Loop resistance:45 nF/km nom.Mutual capacitance:77 %Rel. propagation velocity:

Typical values30020010062,51610(MHz)Frequency4,73,92,72,21,10,9(db/10m)Attenuation73,076,080,083,088,090,0(db)Next68,372,177,380,886,989,1(db)ACR

Technical dataapprox. 37 kg/kmWeight:48 mmMin. bending radius for laying:-20°COperating temperature range min.:+60°COperating temperature range max.:0,41 MJ/mCaloric load, approx. value:20,00 kg/kmCopper weight:

NormsAcc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 6, Flame-retardant acc.to IEC 60332-1, Smoke density acc. to IEC 61034, CMX 444

ApplicationHELUKAT®300 data cables are used in the tertiary level of a network as patch cables and connection cables. They are characterized by largeperformance reserves and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet,Ethernet, ATM155, FDDI, token ring 4/16 Mbit/s, or ISDN absolutely trouble-free. With its optimized construction, the HELUKAT®300 seriescan be manufactured quickly and easily with all common RJ45 plugs. This type is certified according UL because of the special PVC jacket.

802174, U-STP 4x2xAWG 26/7 PVCPart no.Dimensions and specifications may be changed without prior notice.

R 65

450LAN CableCategory 6

S-STP

S-STP 4x2xAWG 24/1 FRNCCable structure0,52 mmInner conductor diameter:Copper, bareConductor material:Foam-skin-PECore insulation:wh/bu, wh/og, wh/gn, wh/bnCore colours:-Shielding 1:Polyester foil, aluminium-linedScreen over stranding element:Polyester foil, aluminium-linedScreen 1 over stranding:-Screen 2 over stranding:FRNCOuter sheath material:approx. 7,4 mmOuter diameter:Green similar to RAL 6018Outer sheath colour:

Electrical data100 Ohm ± 15 ohm at 1 to 100 MHzCharacteristic impedance:100 Ohm ± 20 ohm at 101 to 450 MHz146 Ohm/km max.Loop resistance:43 nF/km nom.Mutual capacitance:79 %Rel. propagation velocity:

Typical values45030020010062,51610(MHz)Frequency38,534,026,017,613,87,05,4(dB/100m)Attenuation84,387,091,094,595,8100,0100,0(db)Next45,853,065,076,982,093,094,6(db)ACR

Technical dataapprox. 50 kg/kmWeight:59 mmMin. bending radius for laying:-20°COperating temperature range min.:+60°COperating temperature range max.:0,57 MJ/mCaloric load, approx. value:24,00 kg/kmCopper weight:

NormsAcc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 6, Flame-retardant acc.to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to 60754-2, Corrosivenessacc. to EN50267-2-3

ApplicationHELUKAT®450 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performancereserves and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155,FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the applicationin tight cable channels and platforms due to their optimized construction.

82501, S-STP 4x2xAWG 24/1 FRNC (S/FTP)Part no.Dimensions and specifications may be changed without prior notice.

R 66

R

450LAN CableCategory 6

S-STP duplex

S-STP 2x(4x2xAWG 24/1) FRNCCable structure0,52 mmInner conductor diameter:Copper, bareConductor material:Foam-skin-PECore insulation:wh/bu, wh/og, wh/gn, wh/bnCore colours:-Shielding 1:Polyester foil, aluminium-linedScreen over stranding element:Polyester foil, aluminium-linedScreen 1 over stranding:-Screen 2 over stranding:FRNCOuter sheath material:approx. 7,4 mm x 15,0 mmCable dimensions:Green similar to RAL 6018Outer sheath colour:

Electrical data100 Ohm ± 15 ohm at 1 to 100 MHzCharacteristic impedance:100 Ohm ± 20 ohm at 101 to 450 MHz146 Ohm/km max.Loop resistance:43 nF/km nom.Mutual capacitance:79 %Rel. propagation velocity:

Typical values45030020010062,51610(MHz)Frequency38,534,026,017,613,87,05,4(dB/100m)Attenuation84,387,091,094,595,8100,0100,0(db)Next45,853,065,076,982,093,094,6(db)ACR

Technical dataapprox. 100 kg/kmWeight:59 mmMin. bending radius for laying:-20°COperating temperature range min.:+60°COperating temperature range max.:1,14 MJ/mCaloric load, approx. value:48,00 kg/kmCopper weight:

NormsAcc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 6, Flame-retardant acc.to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to 60754-2, Corrosivenessacc. to EN50267-2-3

ApplicationHELUKAT®450 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performancereserves and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155,FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the applicationin tight cable channels and platforms due to their optimized construction.

82502, S-STP 2x(4x2xAWG 24/1) FRNC (S/FTP)Part no.Dimensions and specifications may be changed without prior notice.

R 67

500LAN CableCategory 6A

F-FTP

F/FTP 4x2xAWG 23/1 LSZHCable structure0,57 mmInner conductor diameter:Copper, bareConductor material:Foam-skin-PECore insulation:wh/bu, wh/og, wh/gn, wh/bnCore colours:-Shielding 1:Polyester foil, aluminium-linedScreen over stranding element:Polyester foil, aluminium-linedScreen 1 over stranding:-Screen 2 over stranding:LSZHOuter sheath material:approx. 7,5 mmOuter diameter:Blue Lilac similar to RAL 4005Outer sheath colour:

Electrical data100 Ohm ± 15 ohm at 1 to 100 MHzCharacteristic impedance:100 Ohm ± 20 ohm at 101 to 500 MHz160 Ohm/km max.Loop resistance:45 nF/km nom.Mutual capacitance:80 %Rel. propagation velocity:

Typical values50030025020010062,51610(MHz)Frequency41,831,929,025,818,114,27,25,7(db/100m)Attenuation86,990,291,492,997,4100,0100,0100,0(db)Next45,158,362,467,179,385,892,894,3(db)ACR

Technical dataapprox. 50 kg/kmWeight:100 mmMin. bending radius for laying:-20°COperating temperature range min.:+60°COperating temperature range max.:0,55 MJ/mCaloric load, approx. value:28,00 kg/kmCopper weight:

NormsAcc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 6A,Flame-retardant acc. to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to60754-2, Corrosiveness acc. to EN50267-2-3

ApplicationHELUKAT® 500 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performancereserves and outstanding performance. They can be used to implement services such as 10Gigabit Ethernet, Gigabit Ethernet, Fast Ethernet,Ethernet, ATM155, FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suitedfor the application in tight cable channels and platforms due to their optimized construction.

803378, F-FTP 4x2xAWG 23/1 LSZHPart no.Dimensions and specifications may be changed without prior notice.

R 68

R

500LAN CableKategorie 6A

F-FTP duplex

F/FTP 2x(4x2xAWG 23/1) LSZHCable structure0,57 mmInner conductor diameter:Copper, bareConductor material:Foam-skin-PECore insulation:wh/bu, wh/og, wh/gn, wh/bnCore colours:-Shielding 1:Polyester foil, aluminium-linedScreen over stranding element:Polyester foil, aluminium-linedScreen 1 over stranding:-Screen 2 over stranding:LSZHOuter sheath material:approx. 7,8 mm x 15,9 mmCable dimensions:Blue Lilac similar to RAL 4005Outer sheath colour:

Electrical data100 Ohm ± 15 ohm at 1 to 100 MHzCharacteristic impedance:100 Ohm ± 20 ohm at 101 to 500 MHz160 Ohm/km max.Loop resistance:45 nF/km nom.Mutual capacitance:80 %Rel. propagation velocity:

Typical values50030025020010062,51610(MHz)Frequency41,831,929,025,818,114,27,25,7(db/100m)Attenuation86,990,291,492,997,4100,0100,0100,0(db)Next45,158,362,467,179,385,892,894,3(db)ACR

Technical dataapprox. 100 kg/kmWeight:100 mmMin. bending radius for laying:-20°COperating temperature range min.:+60°COperating temperature range max.:1,13 MJ/mCaloric load, approx. value:56,00 kg/kmCopper weight:

NormsAcc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 6A,Flame-retardant acc. to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to60754-2, Corrosiveness acc. to EN50267-2-3

ApplicationHELUKAT® 500 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performancereserves and outstanding performance. They can be used to implement services such as 10Gigabit Ethernet, Gigabit Ethernet, Fast Ethernet,Ethernet, ATM155, FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suitedfor the application in tight cable channels and platforms due to their optimized construction.

803379, Part no.Dimensions and specifications may be changed without prior notice.

R 69

F/FTP 2x(4x2xAWG 23/1) LSZH

500LAN CableCategory 6A

F-FTP, flex

U/FTP 4x2xAWG 26/7 (stranded) LSZHCable structure0,48 mmInner conductor diameter:Copper, bareConductor material:Foam-skin-PECore insulation:wh/bu, wh/og, wh/gn, wh/bnCore colours:-Shielding 1:Polyester foil, aluminium-linedScreen over stranding element:-Screen 1 over stranding:-Screen 2 over stranding:LSZHOuter sheath material:approx. 5,8 mmOuter diameter:Grey similar to RAL 7035Outer sheath colour:

Electrical data100 Ohm ± 15 ohm at 1 to 100 MHzCharacteristic impedance:100 Ohm ± 20 ohm at 101 to 500 MHz165 Ohm/km max.Loop resistance:54 nF/km nom.Mutual capacitance:78 %Rel. propagation velocity:

Typical values50025020010062,51610(MHz)Frequency6,34,43,92,72,11,10,8(dB/10m)Attenuation86,091,092,097,0100,0100,0100,0(db)Next79,786,688,194,397,998,999,2(db)ACR

Technical dataapprox. 35 kg/kmWeight:49 mmMin. bending radius for laying:-20°COperating temperature range min.:+60°COperating temperature range max.:0,39 MJ/mCaloric load, approx. value:15,00 kg/kmCopper weight:

NormsAcc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 6A,Flame-retardant acc. to IEC 60332-1, Smoke density acc. to IEC 61034, Halogen-free acc. to60754-2, Corrosiveness acc. to EN50267-2-3

ApplicationHELUKAT® 500 data cables are used in the tertiary level of a network as patch cables and connection cables. They are characterized by largeperformance reserves and outstanding performance. They can be used to implement services such as 10Gigabit Ethernet, Gigabit Ethernet,Fast Ethernet, Ethernet, ATM155, FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. With its optimized construction, the HELUKAT®500series can be manufactured quickly and easily with many common RJ45 plugs.

804043, U/FTP 4x2xAWG 26/7 LSZHPart no.Dimensions and specifications may be changed without prior notice.

R 70

R

600LAN CableCategory 7e

S-STP

S-STP 4x2xAWG 23/1 FRNCCable structure0,57 mmInner conductor diameter:Copper, bareConductor material:Foam-skin-PECore insulation:wh/bu, wh/og, wh/gn, wh/bnCore colours:-Shielding 1:Polyester foil, aluminium-linedScreen over stranding element:Cu braidScreen 1 over stranding:-Screen 2 over stranding:FRNCOuter sheath material:approx. 7,5 mmOuter diameter:Blue Lilac similar to RAL 4005Outer sheath colour:

Electrical data100 Ohm ± 15 ohm at 1 to 100 MHzCharacteristic impedance:100 Ohm ± 20 ohm at 101 to 1000 MHz130 Ohm/km max.Loop resistance:43 nF/km nom.Mutual capacitance:79 %Rel. propagation velocity:

Typical values100090060030020010062,51610(MHz)Frequency58,055,044,932,125,217,513,97,15,6(dB/100m)Attenuation69,071,073,084,088,094,096,0100,0100,0(db)Next9,016,028,151,962,876,582,192,994,4(db)ACR

Technical dataapprox. 60 kg/kmWeight:60 mmMin. bending radius for laying:-20°COperating temperature range min.:+60°COperating temperature range max.:0,60 MJ/mCaloric load, approx. value:30,00 kg/kmCopper weight:

NormsAcc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7e,Flame-retardant acc. to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to60754-2, Corrosiveness acc. to EN50267-2-3

ApplicationHELUKAT®600 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performancereserves and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155,FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the applicationin tight cable channels and platforms due to their optimized construction.

80810, S-STP 4x2xAWG 23/1 FRNC (S/FTP)Part no.Dimensions and specifications may be changed without prior notice.

R 71

600LAN CableCategory 7e

S-STP duplex

S-STP 2x(4x2xAWG 23/1) FRNCCable structure0,57 mmInner conductor diameter:Copper, bareConductor material:Foam-skin-PECore insulation:wh/bu, wh/og, wh/gn, wh/bnCore colours:-Shielding 1:Polyester foil, aluminium-linedScreen over stranding element:Cu braidScreen 1 over stranding:-Screen 2 over stranding:FRNCOuter sheath material:approx. 7,5 mm x 16,0 mmCable dimensions:Blue Lilac similar to RAL 4005Outer sheath colour:

Electrical data100 Ohm ± 15 ohm at 1 to 100 MHzCharacteristic impedance:100 Ohm ± 20 ohm at 101 to 1000 MHz130 Ohm/km max.Loop resistance:43 nF/km nom.Mutual capacitance:79 %Rel. propagation velocity:

Typical values100090060030020010062,51610(MHz)Frequency58,055,044,932,125,217,513,97,15,6(dB/100m)Attenuation69,071,073,084,088,094,096,0100,0100,0(db)Next9,016,028,151,962,876,582,192,994,4(db)ACR

Technical dataapprox. 120 kg/kmWeight:60 mmMin. bending radius for laying:-20°COperating temperature range min.:+60°COperating temperature range max.:1,20 MJ/mCaloric load, approx. value:60,00 kg/kmCopper weight:

NormsAcc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7e,Flame-retardant acc. to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to60754-2, Corrosiveness acc. to EN50267-2-3

ApplicationHELUKAT®600 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performancereserves and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155,FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the applicationin tight cable channels and platforms due to their optimized construction.

81446, S-STP 2x(4x2xAWG 23/1) FRNC (S/FTP)Part no.Dimensions and specifications may be changed without prior notice.

R 72

R

600LAN CableCategory 7

S-STP flex

S-STP 4x2xAWG 26/7 FRNCCable structure0,48 mmInner conductor diameter:Copper, bareConductor material:Foam-skin-PECore insulation:wh/bu, wh/og, wh/gn, wh/bnCore colours:-Shielding 1:Polyester foil, aluminium-linedScreen over stranding element:Cu braidScreen 1 over stranding:-Screen 2 over stranding:FRNCOuter sheath material:approx. 5,9 mmOuter diameter:Grey similar to RAL 7035Outer sheath colour:

Electrical data100 Ohm ± 15 ohm at 1 to 100 MHzCharacteristic impedance:100 Ohm ± 20 ohm at 101 to 600 MHz264 Ohm/km max.Loop resistance:45 nF/km nom.Mutual capacitance:77 %Rel. propagation velocity:

Typical values60030020010062,51610(MHz)Frequency6,34,94,02,62,01,00,8(dB/10m)Attenuation80,086,088,094,095,096,096,0(db)Next73,781,184,091,493,095,095,2(db)ACR

Technical dataapprox. 42 kg/kmWeight:55 mmMin. bending radius for laying:-20°COperating temperature range min.:+60°COperating temperature range max.:0,47 MJ/mCaloric load, approx. value:22,00 kg/kmCopper weight:

NormsAcc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7, Flame-retardant acc.to IEC 60332-1, Smoke density acc. to IEC 61034, Halogen-free acc. to 60754-2, Corrosivenessacc. to EN50267-2-3

ApplicationHELUKAT®600 data cables are used in the tertiary level of a network as patch cables and connection cables. They are characterized by largeperformance reserves and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet,Ethernet, ATM155, FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. With its optimized construction, the HELUKAT®600 seriescan be manufactured quickly and easily with all common RJ45 plugs.

80294, S-STP 4x2xAWG 26/7 FRNC (S/FTP)Part no.Dimensions and specifications may be changed without prior notice.

R 73

600ALAN Cable OutdoorCategory 7

S-STP PVC/PVC

S-STP 4x2xAWG 23/1 PVC/PVCCable structure0,58 mmInner conductor diameter:Copper, bareConductor material:Foam-skin-PECore insulation:wh/bu, wh/og, wh/gn, wh/bnCore colours:-Shielding 1:PVCInner sheath material:Polyester foil, aluminium-linedScreen over stranding element:Cu braidScreen 1 over stranding:-Screen 2 over stranding:PVCOuter sheath material:approx. 11,6 mmOuter diameter:Black similar to RAL 9005Outer sheath colour:

Electrical data100 Ohm ± 15 ohm at 1 to 100 MHzCharacteristic impedance:100 Ohm ± 20 ohm at 101 to 600 MHz160 Ohm/km max.Loop resistance:43 nF/km nom.Mutual capacitance:79 %Rel. propagation velocity:

Typical values60030020010062,51610(MHz)Frequency49,032,126,218,414,67,45,8(dB/100m)Attenuation80,080,083,085,085,085,085,0(db)Next31,047,956,866,670,477,679,2(db)ACR

Technical dataapprox. 153 kg/kmWeight:95 mmMin. bending radius for laying:-30°COperating temperature range min.:+70°COperating temperature range max.:2,62 MJ/mCaloric load, approx. value:32,00 kg/kmCopper weight:

NormsAcc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7, Flame-retardant acc.to IEC 60332-1, Smoke density acc. to IEC 61034

ApplicationHELUKAT® 600 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performancereserves and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155,FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. The serie of HELUKAT® 600A with a double PVC jacket is constructed especiallyfor outdoor applications like laying at house walls or in cable lines.

801147, S-STP 4x2xAWG 23/1 PVC/PVC (S/FTP)Part no.Dimensions and specifications may be changed without prior notice.

R 74

R

600ELAN Cable Direct BurialCategory 7

S-STP PVC

S-STP 4x2xAWG 23/1 direct burialCable structure0,58 mmInner conductor diameter:Copper, bareConductor material:POCore insulation:wh/bu, wh/og, wh/gn, wh/bnCore colours:-Shielding 1:Polyester foil, aluminium-linedScreen over stranding element:Cu braidScreen 1 over stranding:-Screen 2 over stranding:PVCOuter sheath material:approx. 9,8 mmOuter diameter:BlackOuter sheath colour:

Electrical data100 Ohm ± 15 ohm at 1 to 100 MHzCharacteristic impedance:100 Ohm ± 20 ohm at 101 to 600 MHz150 Ohm/km max.Loop resistance:42 nF/km nom.Mutual capacitance:79 %Rel. propagation velocity:

Typical values60030020010062,51610(MHz)Frequency49,032,126,218,414,67,45,8(dB/100m)Attenuation80,080,083,085,085,085,085,0(db)Next31,047,956,866,670,477,679,2(db)ACR

Technical dataapprox. 102 kg/kmWeight:100 mmMin. bending radius for laying:-45°COperating temperature range min.:+65°COperating temperature range max.:1,40 MJ/mCaloric load, approx. value:32,00 kg/kmCopper weight:

NormsAcc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7, Flame-retardant acc.to IEC 60332-1, Smoke density acc. to IEC 61034, UL 1581 VW-1

ApplicationHELUKAT® 600 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performancereserves and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155,FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. The serie of HELUKAT® 600E with a cold resistant PVC jacket is constructedespecially for outdoor applications like laying at house walls or direct burial.

802167, S-STP 4x2xAWG23/1 PVC (S/FTP)Part no.Dimensions and specifications may be changed without prior notice.

R 75

600AELAN Cable / armouredCategory 7

S-STP FRNC/PE

S-STP 4x2xAWG 23/1 FRNC/PECable structure0,58 mmInner conductor diameter:Copper, bareConductor material:Foam-skin-PECore insulation:wh/bu, wh/og, wh/gn, wh/bnCore colours:-Shielding 1:FRNCInner sheath material:Polyester foil, aluminium-linedScreen over stranding element:Cu braidScreen 1 over stranding:-Screen 2 over stranding:Steel shaft:PEOuter sheath material:approx. 12,2 mmOuter diameter:BlackOuter sheath colour:

Electrical data100 Ohm ± 15 ohm at 1 to 100 MHzCharacteristic impedance:100 Ohm ± 20 ohm at 101 to 600 MHz150 Ohm/km max.Loop resistance:43 nF/km nom.Mutual capacitance:79 %Rel. propagation velocity:

Typical values60030020010062,51610(MHz)Frequency49,032,126,218,414,67,45,8(dB/100m)Attenuation80,080,083,085,085,085,085,0(db)Next31,047,956,866,670,477,679,2(db)ACR

Technical dataapprox. 155 kg/kmWeight:330 mmMin. bending radius for laying:-45°COperating temperature range min.:+70°COperating temperature range max.:2,30 MJ/mCaloric load, approx. value:32,00 kg/kmCopper weight:

NormsAcc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7

ApplicationHELUKAT® 600 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performancereserves and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155,FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. The serie of HELUKAT® 600AE with a FRNC/PE double jacket and the rodentprotection is constructed especially for outdoor and direct burial applications.

802168, S-STP 4x2xAWG 23/1 FRNC/PEPart no.Dimensions and specifications may be changed without prior notice.

R 76

R

1200LAN CableCategory 7A

S-STP

S/FTP 4x2xAWG 23/1 LSZHCable structure0,57 mmInner conductor diameter:Copper, bareConductor material:Foam-skin-PECore insulation:wh/bu, wh/og, wh/gn, wh/bnCore colours:-Shielding 1:Polyester foil, aluminium-linedScreen over stranding element:Cu braidScreen 1 over stranding:-Screen 2 over stranding:LSZHOuter sheath material:approx. 7,9 mmOuter diameter:Blue Lilac similar to RAL 4005Outer sheath colour:

Electrical data100 Ohm ± 15 ohm at 1 to 100 MHzCharacteristic impedance:100 Ohm ± 20 ohm at 101 to 1200 MHz160 Ohm/km max.Loop resistance:45 nF/km nom.Mutual capacitance:80 %Rel. propagation velocity:

Typical values1200100090060030020010062,51610(MHz)Frequency62,156,353,242,929,824,216,913,36,85,4(db/100m)Attenuation82,084,085,088,093,095,0100,0105,0105,0105,0(db)Next19,927,731,845,163,270,883,191,798,299,6(db)ACR

Technical dataapprox. 60 kg/kmWeight:60 mmMin. bending radius for laying:-20°COperating temperature range min.:+60°COperating temperature range max.:0,56 MJ/mCaloric load, approx. value:35,00 kg/kmCopper weight:

NormsAcc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7A,Flame-retardant acc. to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to60754-2, Corrosiveness acc. to EN50267-2-3

ApplicationHELUKAT®1200-7A data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performancereserves and outstanding performance. They can be used to implement services such as 10Gigabit Ethernet, Gigabit Ethernet, Fast Ethernet,Ethernet, ATM155, FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suitedfor the application in tight cable channels and platforms due to their optimized construction.

803380, S-STP 4x2xAWG 23/1 LSZH (S/FTP)Part no.Dimensions and specifications may be changed without prior notice.

R 77

1200LAN CableCategory 7A

S-STP duplex

S/FTP 4x2xAWG 23/1 LSZHCable structure0,57 mmInner conductor diameter:Copper, bareConductor material:Foam-skin-PECore insulation:wh/bu, wh/og, wh/gn, wh/bnCore colours:-Shielding 1:Polyester foil, aluminium-linedScreen over stranding element:Cu braidScreen 1 over stranding:-Screen 2 over stranding:LSZHOuter sheath material:approx. 16,8 mm x 7,9 mmCable dimensions:Blue Lilac similar to RAL 4005Outer sheath colour:

Electrical data100 Ohm ± 15 ohm at 1 to 100 MHzCharacteristic impedance:100 Ohm ± 20 ohm at 101 to 1200 MHz160 Ohm/km max.Loop resistance:56 nF/km nom.Mutual capacitance:80 %Rel. propagation velocity:

Typical values1200100090060030020010062,51610(MHz)Frequency62,156,353,242,929,824,216,913,36,85,4(db/100m)Attenuation82,084,085,088,093,095,0100,0105,0105,0105,0(db)Next19,927,731,845,163,270,883,191,798,299,6(db)ACR

Technical dataapprox. 120 kg/kmWeight:60 mmMin. bending radius for laying:-20°COperating temperature range min.:+60°COperating temperature range max.:1,15 MJ/mCaloric load, approx. value:70,00 kg/kmCopper weight:

NormsAcc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7A,Flame-retardant acc. to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to60754-2, Corrosiveness acc. to EN50267-2-3

ApplicationHELUKAT®1200-7A data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performancereserves and outstanding performance. They can be used to implement services such as 10Gigabit Ethernet, Gigabit Ethernet, Fast Ethernet,Ethernet, ATM155, FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suitedfor the application in tight cable channels and platforms due to their optimized construction.

803381, S-STP 4x2xAWG 23/1 LSZH (S/FTP)Part no.Dimensions and specifications may be changed without prior notice.

R 78

R

1200LAN CableCategory 7e

S-STP

S-STP 4x2xAWG 22/1 FRNCCable structure0,64 mmInner conductor diameter:Copper, bareConductor material:Foam-skin-PECore insulation:wh/bu, wh/og, wh/gn, wh/bnCore colours:-Shielding 1:Polyester foil, aluminium-linedScreen over stranding element:Cu braidScreen 1 over stranding:-Screen 2 over stranding:FRNCOuter sheath material:approx. 7,7 mmOuter diameter:

Electrical data100 Ohm ± 15 ohm at 1 to 100 MHzCharacteristic impedance:100 Ohm ± 20 ohm at 101 to 1200 MHz120 Ohm/km max.Loop resistance:43 nF/km nom.Mutual capacitance:79 %Rel. propagation velocity:

Typical values1200100060030020010062,51610(MHz)Frequency59,053,042,829,423,516,312,76,34,9(dB/100m)Attenuation77,078,081,087,090,093,095,0100,0100,0(db)Next18,025,038,257,666,576,782,393,795,1(db)ACR

Technical dataapprox. 66 kg/kmWeight:72 mmMin. bending radius for laying:-20°COperating temperature range min.:+60°COperating temperature range max.:0,70 MJ/mCaloric load, approx. value:40,00 kg/kmCopper weight:

NormsAcc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7e,Flame-retardant acc. to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to60754-2, Corrosiveness acc. to EN50267-2-3

ApplicationHELUKAT®1200 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performancereserves and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155,FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the applicationin tight cable channels and platforms due to their optimized construction.

81699, S-STP 4x2xAWG 22/1 FRNC (S/FTP)Part no.Dimensions and specifications may be changed without prior notice.

R 79

1200LAN CableCategory 7e

S-STP duplex

S-STP 2x(4x2xAWG 22/1) FRNCCable structure0,64 mmInner conductor diameter:Copper, bareConductor material:Foam-skin-PECore insulation:wh/bu, wh/og, wh/gn, wh/bnCore colours:-Shielding 1:Polyester foil, aluminium-linedScreen over stranding element:Cu braidScreen 1 over stranding:-Screen 2 over stranding:FRNCOuter sheath material:approx. 7,7 mm x 16,5 mmCable dimensions:

Electrical data100 Ohm ± 15 ohm at 1 to 100 MHzCharacteristic impedance:100 Ohm ± 20 ohm at 101 to 1200 MHz120 Ohm/km max.Loop resistance:43 nF/km nom.Mutual capacitance:79 %Rel. propagation velocity:

Typical values1200100060030020010062,51610(MHz)Frequency59,053,042,829,423,516,312,76,34,9(dB/100m)Attenuation77,078,081,087,090,093,095,0100,0100,0(db)Next18,025,038,257,666,576,782,393,795,1(db)ACR

Technical dataapprox. 133 kg/kmWeight:72 mmMin. bending radius for laying:-20°COperating temperature range min.:+60°COperating temperature range max.:1,50 MJ/mCaloric load, approx. value:80,00 kg/kmCopper weight:

NormsAcc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7e,Flame-retardant acc. to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to60754-2, Corrosiveness acc. to EN50267-2-3

ApplicationHELUKAT®1200 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performancereserves and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155,FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the applicationin tight cable channels and platforms due to their optimized construction.

800647, S-STP 2x(4x2xAWG 22/1) FRNC (S/FTP)Part no.Dimensions and specifications may be changed without prior notice.

R 80

R

1500Multimedia CableCategory 7e

S-STP

S-STP 4x2xAWG 22/1 FRNCCable structure0,64 mmInner conductor diameter:Copper, bareConductor material:Foam-skin-PECore insulation:wh/bu, wh/og, wh/gn, wh/bnCore colours:-Shielding 1:Polyester foil, aluminium-linedScreen over stranding element:Cu braidScreen 1 over stranding:-Screen 2 over stranding:FRNCOuter sheath material:approx. 8,6 mmOuter diameter:

Electrical data100 Ohm ± 15 ohm at 1 to 100 MHzCharacteristic impedance:100 Ohm ± 20 ohm at 101 to 1200 MHz120 Ohm/km max.Loop resistance:42 nF/km nom.Mutual capacitance:80 %Rel. propagation velocity:

Typical values15001200100060030020010062,51610(MHz)Frequenz62,054,949,037,727,521,514,412,76,34,2(db/100m)Dämpfung73,088,092,0100,0105,0110,0110,0110,0110,0110,0(db)Next11,033,143,062,377,588,595,697,3103,7106,0(db)ACR

Technical dataapprox. 80 kg/kmWeight:68 mmMin. bending radius for laying:-20°COperating temperature range min.:+60°COperating temperature range max.:0,74 MJ/mCaloric load, approx. value:53,00 kg/kmCopper weight:

NormsAcc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7e,Flame-retardant acc. to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to60754-2, Corrosiveness acc. to EN50267-2-3

ApplicationHELUKAT® 1500 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performancereserves and outstanding performance. They can be used to implement services such as 10Gigabit Ethernet, Gigabit Ethernet, Fast Ethernet,Ethernet, ATM155, FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. That means applications such as multimedia (TV, Video, Data,Speach) are no problem for this series.Likewise, the mechanical characteristics are perfectly suited for the application in tight cable channelsand platforms due to their optimized construction.

802169, S-STP 4x2xAWG 22/1 FRNC (S/FTP)Part no.Dimensions and specifications may be changed without prior notice.

R 81

1500Multimedia CableCategory 7e

S-STP duplex

S-STP 2x(4x2xAWG 22/1) FRNCCable structure0,64 mmInner conductor diameter:Copper, bareConductor material:Foam-skin-PECore insulation:wh/bu, wh/og, wh/gn, wh/bnCore colours:-Shielding 1:Polyester foil, aluminium-linedScreen over stranding element:Cu braidScreen 1 over stranding:-Screen 2 over stranding:FRNCOuter sheath material:approx. 8,6 mm x 18,2 mmCable dimensions:

Electrical data100 Ohm ± 15 ohm at 1 to 100 MHzCharacteristic impedance:100 Ohm ± 20 ohm at 101 to 1200 MHz120 Ohm/km max.Loop resistance:42 nF/km nom.Mutual capacitance:80 %Rel. propagation velocity:

Typical values15001200100060030020010062,51610(MHz)Frequency62,054,949,037,727,521,514,412,76,34,2(db/100m)Attenuation73,088,092,0100,0105,0110,0110,0110,0110,0110,0(db)Next11,033,143,062,377,588,595,697,3103,7106,0(db)ACR

Technical dataapprox. 160 kg/kmWeight:68 mmMin. bending radius for laying:-20°COperating temperature range min.:+60°COperating temperature range max.:1,50 MJ/mCaloric load, approx. value:106,00 kg/kmCopper weight:

NormsAcc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7e,Flame-retardant acc. to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to60754-2, Corrosiveness acc. to EN50267-2-3

ApplicationHELUKAT®1500 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performancereserves and outstanding performance. They can be used to implement services such as 10Gigabit Ethernet, Gigabit Ethernet, Fast Ethernet,Ethernet, ATM155, FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. That means applications such as multimedia (TV, Video, Data,Speach) are no problem for this series.Likewise, the mechanical characteristics are perfectly suited for the application in tight cable channelsand platforms due to their optimized construction.

802170, S-STP 2x(4x2xAWG 22/1) FRNC (S/FTP)Part no.Dimensions and specifications may be changed without prior notice.

R 82

R

TWINAXLAN CableIBM P/N 7 362 211

Twinax indoor or outdoorCable structure

1 x AWG 20, Copper, bare + 1 x AWG 20,Copper, tinned

Inner conductor diameter:

Copper, bareConductor material:PECore insulation:TransparentCore colours:Solid PE dielectricScreen over stranding element:-Screen over stranding 1:Cu braid, tinnedScreen over stranding 2:PVC / PEOuter sheath material:approx. 8,3 mm / approx. 9,3 mmOuter diameter:BlackOuter sheath colour:

Electrical data105 Ohm Characteristic impedance:53 nF/km nom.Mutual capacitance:66 %Rel. propagation velocity:

Typical values100(MHz)Frequency14,0(dB/100m)Attenuation

Technical dataapprox. 88 kg/kmWeight:125 mmMin. bending radius for laying:-10°COperating temperature range min.:+80°COperating temperature range max.:51,00 kg/kmCopper weight:

ApplicationHELUKABEL® TWINAX cables are used in the area of the IBM computer systems S/36, S/38 and AS400. By using a special PE sheath, an outdoorversion was developed as well.

80073, IBM P/N 7362211 Twinax outdoor80072, IBM P/N 7362211 Twinax indoorPart no.Dimensions and specifications may be changed without prior notice.

R 83

IVSLAN CableIBM P/N 33G2772, IBM P/N 33G8224, IBM P/N 33G2775

IBM P/N 33G8224type 1A mini

IBM P/N 33G2775type 6A

IBM P/N 33G2772type 1A

Cable structure

0,4 mm0,48 mm0,64 mmInner conductor diameter:Copper, bareCopper, bareCopper, bareConductor material:Foam-skin-PEFoam-skin-PEFoam-skin-PECore insulation:444Number of cores:bk/og, rd/gnbk/og, rd/gnbk/og, rd/gnCore colours:Polyester foil,aluminium-lined

Polyester foil,aluminium-lined

Polyester foil,aluminium-lined

Screen over stranding element:

Cu braid, tinnedCu braid, tinnedCu braid, tinnedScreen over stranding 1:---Screen over stranding 2:PVCPVCPVCOuter sheath material:approx. 5,5 mm x 8,9 mmapprox. 7,8 mmapprox. 7,6 mm x 11,9 mmCable dimensions:BlackBlackBlackOuter sheath colour:

Electrical data150 Ohm150 Ohm

± 15 ohm at 3 to 20 MHz150 Ohm± 15 ohm at 3 to 20 MHz

Characteristic impedance:± 15 ohm at 3 to 20 MHz235 Ohm235 Ohm

± 35.25 ohm at 38.4 kHz185 Ohm± 18.5 ohm at 38.4 kHz ± 23.5 ohm at 38.4 kHz

390 Ohm390 Ohm± 58.5 ohm at 9.6 kHz

270 Ohm± 27 ohm at 9.6 kHz ± 39 ohm at 9.6 kHz

151 Ohm/km151 Ohm/km57,1 Ohm/kmDirect current resistance:78 %-78 %Rel. propagation velocity:

Typical values100201002010020(MHz)Frequency18,77,412,34,918,77,4(dB/100m)Attenuation49,060,039,050,060,080,0(db)Next

Technical dataapprox. 60 kg/kmapprox. 70 kg/kmapprox. 85 kg/kmWeight:84 mm117 mm110 mmMin. bending radius for laying:-10°C-10°C-10°COperating temperature range min.:+70°C+70°C+70°COperating temperature range max.:0,68 MJ/m0,78 MJ/m1,70 MJ/mCaloric load, approx. value:21,00 kg/km25,00 kg/km38,00 kg/kmCopper weight:

ApplicationHELUKABEL® IVS types are used in the area of the IVS system, developed by IBM. They correspond to the wiring guidelines set by IBM.

80070, IBM P/N 33G8224type 1A mini

80071, IBM P/N 33G2775type 6A

80068, IBM P/N 33G2772type 1A

Part no.

Dimensions and specifications may be changed without prior notice.

R 84

R

LAN CableEthernet Cheapernet Cable, Yellow Cable, Transceiver Cable

TransceiverCable

Yellow CableCheapernetCable

Cable structure

0,89 mm2,17 mm0,72 mmInner conductor diameter:Copper, tinnedCopper, bareCopper, tinnedConductor material:PEFoam-skin-PEFoam-skin-PECore insulation:811Number of cores:gn/bu, ye/og, gy/wh, rd/bkTransparentWhiteCore colours:Polyester foil,aluminium-lined

Polyester foil,aluminium-lined

-Screen over stranding element:

-Cu braid, tinnedPolyester foil,aluminium-lined

Screen over stranding 1:

Polyester foil,aluminium-lined

Polyester foil,aluminium-lined

Cu braid, tinnedScreen over stranding 2:

PVCPVCPVCOuter sheath material:approx. 10,6 mmapprox. 10,3 mmapprox. 4,6 mmOuter diameter:GreyYellowGreyOuter sheath colour:

Electrical data78 Ohm50 Ohm50 OhmCharacteristic impedance:64 nF/km nom.78 nF/km nom.88 nF/km nom.Mutual capacitance:--50 Ohm/kmDirect current resistance:66 %85 %77 %Rel. propagation velocity:

Typical values104104104(MHz)Frequency6,04,24,63,31,81,2(dB/100m)Attenuation

Technical dataapprox. 142 kg/kmapprox. 176 kg/kmapprox. 32 kg/kmWeight:159 mm117 mm69 mmMin. bending radius for laying:-10°C-10°C-10°COperating temperature range min.:+60°C+70°C+80°COperating temperature range max.:--0,36 MJ/mCaloric load, approx. value:95,00 kg/km128,00 kg/km21,00 kg/kmCopper weight:

ApplicationHELUKABEL® ETHERNET types are used as baselines (Yellow + Cheapernet) and cable connections (Transceiver or AUI) within the Ethernetwiring structure.

80076, Transceiver cable80074, Yellow cable80044, Cheapernet cablePart no.Dimensions and specifications may be changed without prior notice.

R 85