1
2 1… 7 01/2016 07/2016 360° www.perma-tec.com 6 2 88 1 SET 1. Predefine installation / Select lubricant, discharge period + connecting parts Reducer Remote mounting for lube-points with vibration, limited mounting space, high temperature Direct mounting Select a suitable lubricant for perma NOVA e. g. perma Multipurpose grease SF01 Select discharge period e. g. with perma SELECT Software (refer to our product catalog for details) Possible mounting positions: * This position is only possible in dry environments 2. Prepare lube-point Clean lube-point Remove grease fitting Add reducer and tubes (if required) For remote mounting: Prefill lube-point and any grease lines / connections (use the same grease that is contained in the lubrication system) For direct mounting: Prefill lube-point and any connecting parts (use the same grease that is contained in the lubrication system) Pressure check: Lube-point / all connecting parts (refer to perma NOVA installation guide for details) Remove protection cover from LC unit Attach control unit Screw control unit onto LC unit until arrow lines up (see enlargement) Note activation / exchange date on label Remove plug 3. Activation / Installation of lubrication system * Add sealant perma NOVA - Quick Start Guide Examples: Bearing lubrication Select discharge period 1 - 12 months © 2016/03 · Version: 2.0 · Art. No. 103773 Mounting bracket 1-point G1/4 female (109685) Reducer Hose connector G1/4 male for hose iØ 9.5 mm - push-lock (101554) Heavy Duty hose up to +100 °C oØ 16 mm x iØ 9.5 mm (101555) Hose connector G1/4 male for hose iØ 9.5 mm - push-lock (101554)

Transcript of perma NOVA - Quick Start Guide plug on label 3. Activation / Installation of lubrication system *...

21…

7

01/2016

07/2016

360°

www.perma-tec.com

62

881

SET

Blattformat: DIN A4Maßstab: 1:1

Blattformat: DIN A1Maßstab: 1:1

Blattformat: DIN A1Maßstab: 1:1

Blattformat: DIN A4Maßstab: 1:1 Blattformat: DIN A4

Maßstab: 1:1

Blattformat: DIN A4Maßstab: 1:1

1. Predefine installation / Select lubricant, discharge period + connecting parts

Reducer

Remote mounting for lube-points with vibration, limited mounting space, high temperatureDirect mounting

Select a suitable lubricant for perma NOVA e. g. perma Multipurpose grease SF01

Select discharge period e. g. with perma SELECT Software(refer to our product catalog for details)

Possible mounting positions:

* This position is only possible in dry environments

2. Prepare lube-point

Clean lube-point Remove grease fitting Add reducer and tubes (if required)

For remote mounting: Prefill lube-point and any grease lines / connections

(use the same grease that is contained in the lubrication system)

For direct mounting: Prefill lube-point and any connecting parts

(use the same grease that is contained in the lubrication system)Pressure check: Lube-point / all connecting parts

(refer to perma NOVA installation guide for details)

Remove protection cover from LC unit Attach control unit

Screw control unit onto LC unit until arrow lines up (see enlargement)

Noteactivation / exchange date

on labelRemove plug

3. Activation / Installation of lubrication system

*

Add sealant

perma NOVA - Quick Start Guide

Examples: Bearing lubrication

Select discharge period1 - 12 months

© 2

016/

03 ·

Vers

ion:

2.0

· Ar

t. N

o. 1

0377

3

Mounting bracket 1-point G1/4 female(109685)

Reducer

Hose connector G1/4 male for hose iØ 9.5 mm - push-lock (101554)

Heavy Duty hose up to +100 °C oØ 16 mm x iØ 9.5 mm (101555)

Hose connector G1/4 male for hose iØ 9.5 mm - push-lock (101554)