PERHITUNGAN KUANTITASSISWANTO
1.bin
-
PROSEDUR YANG DIGUNAKAN UNTUK OPERASI SERAH TERIMA (CUSTODY TRANSFER) DI BERBAGAI NEGARA, PORT ATAU TERMINAL / INSTALASI BISA BERBEDA SATU DENGAN LAINNYA.UMUMSIS1207
-
TOV : TOTAL OBSERVED VOLUME.FRA : FLOATING ROOF ADJUSTMENT.CTSh: CORRECTION FOR TEMPERATURE OF TANK SHELL.FW: FREE WATER.GOV: GROSS OBSERVED VOLUME.VCF: VOLUME CORRECTION FACTOR.GSV: GROSS STANDARD VOLUME.WCF: WEIGHT CONVERSION FACTOR.GSW: GROSS STANDARD WEIGHT.ISTILAH DAN SINGKATAN SIS0307
-
S+W: SEDIMEN AND WATER.CSW: CORRECTION (FACTOR) FOR SEDIMENT AND WATER.NSV: NET STANDARD VOLUME.NSW: NET STANDARD WEIGHT.TCV: TOTAL CALCULATED VOLUME.
ISTILAH LAIN (TANPA PENYINGKATAN YANG BAKU):- REFERENCE HEIGHT.- OBSERVED HEIGHT ATAU MEASURED HEIGHT.- WET DENSITY DAN DRY DENSITY.- LOADED DAN DISCHARGED.ISTILAH DAN SINGKATAN SIS0307
-
PENEMPATAN DESIMAL BERIKUT INI (REKOMENDASI DARI API CHAPTER 12.1.1) DIGUNAKAN, SELAMA PROSEDUR PELAPORAN TIDAK BERTENTANGAN DENGAN PRAKTEK TERMINAL.PELAPORAN DESIMALSIS0307
2.bin
-
- TANK REFERENCE HEIGHT.- TANK MEASURED (OBSERVED) HEIGHT.- PRODUCTS DIP (INNAGE) ATAU ULLAGE (OUTAGE).- FREE WATER DIP.- TANK TEMPERATURE (OC / OF).- TANK DENSITY ATAU API GRAVITY.- S+W VOLUME %.- TANK AMBIENT TEMPERATURE.DATA LAPANGANSHORE TANKSSIS0307
-
- FOREWARD DAN AFTERWARD DRAFT.- LIST DEGREE (PORT OR STARBOARD).- TANK REFERENCE HEIGHT.- TANK MEASURED (OBSERVED) HEIGHT.- PRODUCTS DIP (INNAGE) ATAU ULLAGE (OUTAGE).- FREE WATER DIP.- TANK TEMPERATURE (OC / OF).- TANK DENSITY OR API GRAVITY.- S+W VOLUME %.DATA LAPANGANSHIP TANKSSIS0307
-
- DENSITY PADA TEMPERATUR STANDARD (15OC ATAU 60OF).- FLOATING ROOF ADJUSTMENT (FRA).- KOREKSI TEMPERATUR PADA TANK SHELL (CTSh), JIKA ADA.- TOTAL OBSERVED VOLUME (TOV).- FREE WATER VOLUME (FW).- GROSS OBSERVED VOLUME (GOV).- VOLUME CORRECTION FACTOR (VCF / CTL).- GROSS STANDARD VOLUME (GSV).DATA HASIL PERHITUNGANSHORE TANKSSIS0307
-
- SEDIMEN AND WATER (S+W) ATAU CORRECTION FOR SEDIMENT AND WATER (CSW). - NET STANDARD VOLUME (NSV).- WEIGHT CONVERSION FACTOR (WCF).- GROSS STANDARD WEIGHT (GSW).- NET STANDARD WEIGHT (NSW).- TOTAL CALCULATED VOLUME (TCV).DATA HASIL PERHITUNGANSHORE TANKSSIS0307
-
- VESSEL TRIM. - VESSEL TRIM CORRECTION.- VESSEL LIST CORRECTION.- DENSITY AT STANDARDS TEMPERATURE (15OC ATAU 60OF).- TOTAL OBSERVED VOLUME (TOV).- FREE WATER VOLUME (FW).- GROSS OBSERVED VOLUME (GOV).- VOLUME CORRECTION FACTOR (VCF / CTL).- GROSS STANDARD VOLUME (GSV).DATA HASIL PERHITUNGANSHIP TANKSSIS0307
-
- SEDIMEN AND WATER (S+W) ATAU CORRECTION UNTUK SEDIMENT AND WATER (CSW). - NET STANDARD VOLUME (NSV).- WEIGHT CONVERSION FACTOR (WCF).- GROSS STANDARD WEIGHT (GSW).- NET STANDARD WEIGHT (NSW).- TOTAL CALCULATED VOLUME (TCV).DATA HASIL PERHITUNGANSHIP TANKSSIS0307
-
DATA YANG TERBACA PADA TABEL SERINGKALI BERBEDA DENGAN ANGKA YANG MUNCUL, MAKA DIGUNAKAN INTERPOLASI LINIER DENGAN RUMUS SEBAGAI BERIKUT:
(X2 - X) (Y2 - Y1)Y = Y2 - ( ) (X2 - X1)INTERPOLASI LINIERSIS0307
-
FLOW CHART YANG MENJELASKAN VOLUME DAN BERAT YANG BERHUBUNGAN DENGAN FAKTOR KOREKSI DAN KONVERSI.FLOW CHARTSIS0307
-
FLOW CHART YANG MENJELASKAN VOLUME DAN BERAT YANG BERHUBUNGAN DENGAN FAKTOR KOREKSI DAN KONVERSI.FLOW CHARTSIS0307
-
FLOW CHARTSIS0307
-
D1 = (VD - (V2D2 + V3D3)) / V1
KETERANGAN:D = WET DENSITY.V = WET OIL VOLUME.D1 = DRY DENSITY.D2 = WATER DENSITY.D3 = SEDIMENT DENSITY.V1 = DRY OIL VOLUME. V2 = WATER VOLUME. V3 = SEDIMENT VOLUME. PERITUNGAN DRY DENSITY CATATAN:DRY DENSITY TIDAK UMUM UNTUK BANYAK NEGARA, PORT DAN TERMINAL.SIS0307
-
- TRIMMED BY STERN: AFTERWARD DRAFT DIKURANGI FORWARD DRAFT HASILNYA POSITIF.- TRIMMED BY HEAD: AFTERWARD DRAFT DIKURANGI FORWARD DRAFT HASILNYA NEGATIF.- TABEL KOREKSI TRIM ADA DALAM TABEL KALIBRASI TANKI KAPAL, DIGUNAKAN UNTUK MENGOREKSI DIP ATAU ULLAGE .- KOREKSI TRIM BISA POSITIF ATAU NEGATIF.KOREKSI TRIMSIS0307
-
- LIST BIASANYA DIBACA DARI INCLINOMETER.
- STATUS DARI LIST : OPORT, JIKA KAPAL CONDONG KE KIRI, OSTARBOARD, JIKA KAPAL CONDONG KE KANAN.
- TABEL KOREKSI LIST ADA DALAM TABEL KALIBRASI TANKI KAPAL, DIGUNAKAN UNTUK MENGOREKSI DIP ATAU ULLAGE .
- LIST CORRECTION BISA POSITIF ATAU NEGATIF.KOREKSI LISTSIS0307
-
V = (X2 x W) / 2E
KETERANGAN:X = ((( U - (D x E)) x E) + SE = TRIM / LBPV = VOLUME DARI OBQ/ROB.W = LEBAR TANKI.S = SOUNDING (LIQUID DIP READING).U = JARAK DIPPING POINT DAN AFT. BULKHEAD.TRIM = AFT. DRAFT - FWD. DRAFT.LBP = PANJANG KAPAL.WEDGE FORMULASIS0307
-
SATUAN DAN TABEL UNTUK PETROLEUMSIS0307
COSUM T-6
NO.UNITS / TABLESSYSTEM OF UNITS
METRICAMERICANBRITISH
1Linearmm - metresFt - InchFt - Inch
2TemperatureoCoFoF
3Pressurebar - kg/cm2psigpsig
4VolumeLitres - m3Barrels - US GallonsBarrels - Imp. Gallons
5WeightMetric TonsLong Tons - PoundsLong Tons - Pounds
6Density CorrectionTable 53A - (53)Table 5A - (5)Table 23A - (23)
7Density CorrectionTable 51Table 3Table 21
8Volume CorrectionTable 52Table 4Table 22
9Volume CorrectionTable 54A - (54)Table 6A - (6)Table 24A - (24)
10Weight CorrectionTable 56 - 57Table 11 - 13Table 29
CATATAN:SEMUA KALKULASI DALAM SISTEM YANG BERBEDA HARUSLAH
KONSISTEN DALAM UNIT DAN TABELNYA.
-
SATUAN DAN TABELUNTUK PRODUK PETROLEUMSIS0307
CO UNITS
NO.UNITS / TABLESSYSTEM OF UNITS
METRICAMERICANBRITISH
1Linearmm - metresFt - InchFt - Inch
2TemperatureoCoFoF
3Pressurebar - kg/cm2psigpsig
4VolumeLitres - m3Barrels - US GallonsBarrels - Imp. Gallons
5WeightMetric TonsLong Tons - PoundsLong Tons - Pounds
6Density CorrectionTable 53B - 53D - (53)Table 5B - 5D - (5)Table 23B - 23D - (23)
7Density CorrectionTable 51Table 3Table 21
8Volume CorrectionTable 52Table 4Table 22
9Volume CorrectionTable 54B - 54D - (54)Table 6B - 6D - (6)Table 24B - 24D - (24)
10Weight CorrectionTable 56 - 57Table 11 - 13Table 29
CATATAN:SEMUA KALKULASI DALAM SISTEM YANG BERBEDA HARUSLAH
KONSISTEN DALAM UNIT DAN TABELNYA.
-
KUANTITAS TANKI DARATSIS0307
5.bin
-
CONTOH: PERHITUNGAN TANKI DARATSIS0307
COFLR T-6
FLOATING ROOFUNITTANK NO. 1301-A
OPENING (T-6)OPENING (T-6A)REMARKS
1Reference Heightmm1750717507Tank Cap. Table
2Measured Heightmm1750517505Measurement
3ATG / Tank Remotemm1088110881Measurement
4GAUGE: Oil + Watermm1087710877Measurement
5GAUGE: Water onlymm00Measurement
6TemperatureOF90.090.0Measurement
7Total Observed VolumeBbls370476.70370476.70Tank Cap. Table
8Free WaterBbls0.000.00Tank Cap. Table
9CTSh0.99999660.9999966Tank Cap. Table
10Floating Roof AdjustmentBbls58.5058.50Tank Cap. Table
11Gross Observed VolumeBbls370533.94370533.94((7-8)x9)+10
12API40.340.3Analysis Data
13VCF: Table 6 / 6A0.985770.98484Table-6 / 6A
14Gross Standard VolumeBbls365261.24364916.6511 x 13
15WCF: Table 110.128580.12858Table-11
16Gross Standard WeightLong Tons46965.29046920.98314 x 15
17S+W % Volume0.050.05Analysis Data
18S+W VolumeBbls182.63182.4614 x17
19Net Standard VolumeBbls365078.61364734.1914 -18
20WCF: Table 110.128580.12858Table-11
21Net Standard WeightLong Tons46941.80846897.52219 x 20
COFLR T-6A
FLOATING ROOFUNITTANK NO. 1301-A
OPENINGCLOSING
1Reference Heightmm1750717507
2Measured Heightmm1750517505
3ATG / Tank Remotemm108816171
4GAUGE: Oil + Watermm108776168
5GAUGE: Water onlymm00
6TemperatureOF90.088.0
7Total Gauge VolumeBbls370476.70206842.30
8Floating Roof CorrectionBbls/+58.5/1.0000070+58.5/1.0000070
9Total Observed VolumeBbls370537.79206902.25
10Free WaterBbls0.000.00
11Gross Observed VolumeBbls370537.79206902.25
12API40.340.3
13VCF: Table 6A0.984840.98532
14Gross Standard VolumeBbls364920.44203864.92
15GSV DeliveredBbls161055.52
16WCF: Table 110.128580.12858
17Gross Standard WeightLong Tons46921.47026212.951
18GSW DeliveredLong Tons20708.519
19S+W % Volume0.050.05
20S+W VolumeBbls182.46101.93
21Net Standard VolumeBbls364737.98203762.99
22NSV DeliveredBbls160974.99
23WCF: Table 110.128580.12858
24Net Standard WeightLong Tons46898.00926199.845
25NSW DeliveredLong Tons20698.164
-
CONTOH: PERHITUNGAN TANKI DARATSIS0307
COFXR T-6
FIXED ROOFUNITTANK NO. 1301-DREMARKS
OPENINGCLOSING
1Reference Heightmm1750717507Tank Cap. Table
2Measured Heightmm1750517505Measurement
3ATG / Tank Remotemm108816171Measurement
4GAUGE: Oil + Watermm108776168Measurement
5GAUGE: Water onlymm105Measurement
6TemperatureOF90.088.0Measurement
7Total Gauge VolumeBbls370476.70206842.30Tank Cap. Table
8Floating Roof CorrectionBbls/0.000.00Tank Cap. Table
9Total Observed VolumeBbls370476.70206842.307 +/- 8
10Free WaterBbls100.0050.00Tank Cap. Table
11Gross Observed VolumeBbls370376.70206792.309 - 10
12API40.340.3Analysis Data
13VCF: Table 60.985770.98674Table-6
14Gross Standard VolumeBbls365106.24204050.2311 x 13
15GSV DeliveredBbls161056.01OPEN - CLOSE
16WCF: Table 110.128580.12858Table-11
17Gross Standard WeightLong Tons46945.36026236.77914 x 16
18GSW DeliveredLong Tons20708.581OPEN - CLOSE
19S+W % Volume0.050.05Analysis Data
20S+W VolumeBbls182.55102.0314 x19
21Net Standard VolumeBbls364923.69203948.2014 -20
22NSV DeliveredBbls160975.49OPEN - CLOSE
23WCF: Table 110.128580.12858Table-11
24Net Standard WeightLong Tons46921.88826223.66021 x 23
25NSW DeliveredLong Tons20698.228OPEN - CLOSE
COFLR T-6
FLOATING ROOFUNITTANK NO. 1301-AREMARKS
OPENINGCLOSING
1Reference Heightmm1750717507Tank Cap. Table
2Measured Heightmm1750517505Measurement
3ATG / Tank Remotemm108816171Measurement
4GAUGE: Oil + Watermm108776168Measurement
5GAUGE: Water onlymm00Measurement
6TemperatureOF90.088.0Measurement
7Total Observed VolumeBbls370476.70206842.30Tank Cap. Table
8Free WaterBbls0.000.00Tank Cap. Table
9CTSh0.99999661.0000348Tank Cap. Table
10Floating Roof AdjustmentBbls58.5058.50Tank Cap. Table
11Gross Observed VolumeBbls370533.94206908.00((7-8)x9)+10
12API40.340.3Analysis Data
13VCF: Table 60.985770.98674Table-6
14Gross Standard VolumeBbls365261.24204164.411 x 13
15GSV DeliveredBbls161096.84OPEN - CLOSE
16WCF: Table 110.128580.12858Table-11
17Gross Standard WeightLong Tons46965.29026251.45914 x 16
18GSW DeliveredLong Tons20713.831OPEN - CLOSE
19S+W % Volume0.050.05Analysis Data
20S+W VolumeBbls182.63102.0814 x19
21Net Standard VolumeBbls365078.61204062.3214 -20
22NSV DeliveredBbls161016.29OPEN - CLOSE
23WCF: Table 110.128580.12858Table-11
24Net Standard WeightLong Tons46941.80826238.33321 x 23
25NSW DeliveredLong Tons20703.475OPEN - CLOSE
*
-
CONTOH: PERHITUNGAN TANKI DARATSIS0307
COFXR T-6
FIXED ROOFUNITTANK NO. 1301-DREMARKS
OPENINGCLOSING
1Reference Heightmm1750717507Tank Cap. Table
2Measured Heightmm1750517505Measurement
3ATG / Tank Remotemm108816171Measurement
4GAUGE: Oil + Watermm108776168Measurement
5GAUGE: Water onlymm105Measurement
6TemperatureOF90.088.0Measurement
7Total Gauge VolumeBbls370476.70206842.30Tank Cap. Table
8Floating Roof CorrectionBbls/0.000.00Tank Cap. Table
9Total Observed VolumeBbls370476.70206842.307 +/- 8
10Free WaterBbls100.0050.00Tank Cap. Table
11Gross Observed VolumeBbls370376.70206792.309 - 10
12API40.340.3Analysis Data
13VCF: Table 60.985770.98674Table-6
14Gross Standard VolumeBbls365106.24204050.2311 x 13
15GSV DeliveredBbls161056.01OPEN - CLOSE
16WCF: Table 110.128580.12858Table-11
17Gross Standard WeightLong Tons46945.36026236.77914 x 16
18GSW DeliveredLong Tons20708.581OPEN - CLOSE
19S+W % Volume0.050.05Analysis Data
20S+W VolumeBbls182.55102.0314 x19
21Net Standard VolumeBbls364923.69203948.2014 -20
22NSV DeliveredBbls160975.49OPEN - CLOSE
23WCF: Table 110.128580.12858Table-11
24Net Standard WeightLong Tons46921.88826223.66021 x 23
25NSW DeliveredLong Tons20698.228OPEN - CLOSE
COFLR T-6
FIXED ROOFUNITTANK NO. 1301-DREMARKS
OPENINGCLOSING
1Reference Heightmm1750717507Tank Cap. Table
2Measured Heightmm1750517505Measurement
3ATG / Tank Remotemm108816171Measurement
4GAUGE: Oil + Watermm108776168Measurement
5GAUGE: Water onlymm100Measurement
6TemperatureOF90.088.0Measurement
7Total Observed VolumeBbls370476.70206842.30Tank Cap. Table
8Free WaterBbls100.000.00Tank Cap. Table
9CTSh0.99999661.0000348Tank Cap. Table
10Floating Roof AdjustmentBblsn/an/aTank Cap. Table
11Gross Observed VolumeBbls370375.44206849.50(7-8)x9
12API40.340.3Analysis Data
13VCF: Table 60.985770.98674Table-6
14Gross Standard VolumeBbls365105204106.6811 x 13
15GSV DeliveredBbls160998.32OPEN - CLOSE
16WCF: Table 110.128580.12858Table-11
17Gross Standard WeightLong Tons46945.20126244.03714 x 16
18GSW DeliveredLong Tons20701.164OPEN - CLOSE
19S+W % Volume0.050.05Analysis Data
20S+W VolumeBbls182.55102.0514 x19
21Net Standard VolumeBbls364922.45204004.6314 -20
22NSV DeliveredBbls160917.82OPEN - CLOSE
23WCF: Table 110.128580.12858Table-11
24Net Standard WeightLong Tons46921.72926230.91521 x 23
25NSW DeliveredLong Tons20690.814OPEN - CLOSE
-
KUANTITAS TANKI KAPALSIS0307
-
CONTOH: PERHITUNGAN TANKI KAPALSIS0307
Sheet1
Fwd Draft= 9.50 mAft Draft= 11.20 m
SHIP'S TANKS BEFORE LOADINGPort List= 0.00 deg.Stb List= 0.00 deg.
LBP= 230.50 mSea condition= Calm.
PARTICULARTANK NO.
UNIT1P1S2P2S3C
Distance (U)m0.9860.9860.9860.9860.986
Depth (D)m8.3208.3208.3208.3208.320
Sounding (S)m0.0000.0000.0000.0500.100
Length (L)m22.4522.4522.4522.4522.45
Trim/LBP (E)0.007380.007380.007380.007380.00738
Wide (W)m20.34220.34220.34220.34220.342
X ValuemN/AN/AN/A0.056820.10682
Y Valuem0.165680.165680.165680.165680.16568
GOVm30004.44915.726
Table-1 Factorm3 to bbls6.289816.289816.289816.289816.28981
GOVbbls00027.9898.91
GOV Total =126.89bbls
NOTE: The formula valid if X less than Y.
X = ((( U - (D x E)) x E ) + S
E = TRIM / LBP
GOV = ( X2 x W ) / ( 2E )
Y = L x E
TANK NO.XYREMARKS
2S0.056820.16568X < YWedge Calculation
3C0.106820.16568X < YWedge Calculation
-
CONTOH: PERHITUNGAN TANKI KAPALSIS0307
Sheet1
Fwd Draft= 10..00 mAft Draft= 10.00 m
SHIP'S TANKS BEFORE LOADINGPort List= 0.00 deg.Stb List= 0.00 deg.
API= n/aSea condition= Calm.
PARTICULARTANK NO.
UNIT1P1S2P2S3C
Reference Heightmm1905519049188411885118849
Ullagemm1905519049188411884118844
Corrected Ullagemm1905519049188411884118844
TemperatureoFn/an/an/an/an/a
TOVbbls0.000.000.0040.0022.00
Free Water Dipmm00000
Free Water Volumebbls0.000.000.000.000.00
Liqud Hyd. (Level)mm1905519049188411884118844
Liqud Hyd. (Volume)bbls0.000.000.0040.0022.00
Non. Liq. Hyd. (L)mm00000
Non. Liq. Hyd. (Vol.)bbls0.000.000.000.000.00
GOV Total =62.00bbls
FW Total =0.00bbls
Non Liquid Hydrocarbon Total =0.00bbls
-
CONTOH: PERHITUNGAN TANKI KAPALSIS0307
Sheet1
Fwd Draft= 7.10 mAft Draft= 9.70 m
SHIP'S TANKS AFTER LOADINGPort List= 0.00 deg.Stb List= 0.00 deg.
API= 40.3Sea condition= Slight.
PARTICULARTANK NO.
UNIT1P1S2P2S3C
Reference Heightmm1905519049188411885118849
Ullagemm1.531.371.341.371.32
Corrected Ullagemm1.671.521.491.511.47
TemperatureoF9696969696
TOVbbls49973.0010222.00100043.0090968.0049922.00
Free Water Dipmm00.0100.020
Free Water Volumebbls0.0040.000.0080.000.00
GOVbbls49973.0010182.00100043.0090888.0049922.00
VCF T-60.982940.982940.982940.982940.98294
GSVbbls49120.4610008.3098336.2789337.4549070.33
TOV Total =301128.00bbls
GOV Total =301008.00bbls
FW Total =120.00bbls
GSV =295872.81bbls
Catatan:
Corrected Ullage diperoleh dari Ullage yang dikoreksi oleh Trim dan List Correction.
-
CONTOH: PERHITUNGAN TANKI KAPALSIS0307
Sheet1
SHIP'S TANKSUNITSHIP'S TANK NO.: 1P, 1S, 2P, 2S, 3CREMARKS
SUMMARY AT LOADINGB/ LOADINGA/ LOADING
1APIN/A40.3Analysisi Data
2Gross Standard VolumeBbls62.00295872.81Calculation
3GSV LoadedBbls295810.81After - Before
4WCF: Table 110.128580.12858Table-11
5Gross Standard WeightLong Tons7.97238043.3262 x 4
6GSW LoadedLong Tons38035.35After - Before
7S+W % VolumeN/A0.05Analysisi Data
8S+W VolumeBblsN/A147.942 x 7
9Net Standard VolumeBbls62.00295724.872 - 8
10NSV LoadedBbls295662.87After - Before
11WCF: Table 110.128580.12858Table-11
12Net Standard WeightLong Tons7.97238024.3049 x 11
13NSW LoadedLong Tons38016.33After - Before
Assumption :GOV Before Loading as GSV.
WCF Before Loading same as A/Loading.
*