Perhitungan Kuantitas muatan

30
PERHITUNGAN PERHITUNGAN KUANTITAS KUANTITAS SISWANTO

description

maritime

Transcript of Perhitungan Kuantitas muatan

  • PERHITUNGAN KUANTITASSISWANTO

    1.bin

  • PROSEDUR YANG DIGUNAKAN UNTUK OPERASI SERAH TERIMA (CUSTODY TRANSFER) DI BERBAGAI NEGARA, PORT ATAU TERMINAL / INSTALASI BISA BERBEDA SATU DENGAN LAINNYA.UMUMSIS1207

  • TOV : TOTAL OBSERVED VOLUME.FRA : FLOATING ROOF ADJUSTMENT.CTSh: CORRECTION FOR TEMPERATURE OF TANK SHELL.FW: FREE WATER.GOV: GROSS OBSERVED VOLUME.VCF: VOLUME CORRECTION FACTOR.GSV: GROSS STANDARD VOLUME.WCF: WEIGHT CONVERSION FACTOR.GSW: GROSS STANDARD WEIGHT.ISTILAH DAN SINGKATAN SIS0307

  • S+W: SEDIMEN AND WATER.CSW: CORRECTION (FACTOR) FOR SEDIMENT AND WATER.NSV: NET STANDARD VOLUME.NSW: NET STANDARD WEIGHT.TCV: TOTAL CALCULATED VOLUME.

    ISTILAH LAIN (TANPA PENYINGKATAN YANG BAKU):- REFERENCE HEIGHT.- OBSERVED HEIGHT ATAU MEASURED HEIGHT.- WET DENSITY DAN DRY DENSITY.- LOADED DAN DISCHARGED.ISTILAH DAN SINGKATAN SIS0307

  • PENEMPATAN DESIMAL BERIKUT INI (REKOMENDASI DARI API CHAPTER 12.1.1) DIGUNAKAN, SELAMA PROSEDUR PELAPORAN TIDAK BERTENTANGAN DENGAN PRAKTEK TERMINAL.PELAPORAN DESIMALSIS0307

    2.bin

  • - TANK REFERENCE HEIGHT.- TANK MEASURED (OBSERVED) HEIGHT.- PRODUCTS DIP (INNAGE) ATAU ULLAGE (OUTAGE).- FREE WATER DIP.- TANK TEMPERATURE (OC / OF).- TANK DENSITY ATAU API GRAVITY.- S+W VOLUME %.- TANK AMBIENT TEMPERATURE.DATA LAPANGANSHORE TANKSSIS0307

  • - FOREWARD DAN AFTERWARD DRAFT.- LIST DEGREE (PORT OR STARBOARD).- TANK REFERENCE HEIGHT.- TANK MEASURED (OBSERVED) HEIGHT.- PRODUCTS DIP (INNAGE) ATAU ULLAGE (OUTAGE).- FREE WATER DIP.- TANK TEMPERATURE (OC / OF).- TANK DENSITY OR API GRAVITY.- S+W VOLUME %.DATA LAPANGANSHIP TANKSSIS0307

  • - DENSITY PADA TEMPERATUR STANDARD (15OC ATAU 60OF).- FLOATING ROOF ADJUSTMENT (FRA).- KOREKSI TEMPERATUR PADA TANK SHELL (CTSh), JIKA ADA.- TOTAL OBSERVED VOLUME (TOV).- FREE WATER VOLUME (FW).- GROSS OBSERVED VOLUME (GOV).- VOLUME CORRECTION FACTOR (VCF / CTL).- GROSS STANDARD VOLUME (GSV).DATA HASIL PERHITUNGANSHORE TANKSSIS0307

  • - SEDIMEN AND WATER (S+W) ATAU CORRECTION FOR SEDIMENT AND WATER (CSW). - NET STANDARD VOLUME (NSV).- WEIGHT CONVERSION FACTOR (WCF).- GROSS STANDARD WEIGHT (GSW).- NET STANDARD WEIGHT (NSW).- TOTAL CALCULATED VOLUME (TCV).DATA HASIL PERHITUNGANSHORE TANKSSIS0307

  • - VESSEL TRIM. - VESSEL TRIM CORRECTION.- VESSEL LIST CORRECTION.- DENSITY AT STANDARDS TEMPERATURE (15OC ATAU 60OF).- TOTAL OBSERVED VOLUME (TOV).- FREE WATER VOLUME (FW).- GROSS OBSERVED VOLUME (GOV).- VOLUME CORRECTION FACTOR (VCF / CTL).- GROSS STANDARD VOLUME (GSV).DATA HASIL PERHITUNGANSHIP TANKSSIS0307

  • - SEDIMEN AND WATER (S+W) ATAU CORRECTION UNTUK SEDIMENT AND WATER (CSW). - NET STANDARD VOLUME (NSV).- WEIGHT CONVERSION FACTOR (WCF).- GROSS STANDARD WEIGHT (GSW).- NET STANDARD WEIGHT (NSW).- TOTAL CALCULATED VOLUME (TCV).DATA HASIL PERHITUNGANSHIP TANKSSIS0307

  • DATA YANG TERBACA PADA TABEL SERINGKALI BERBEDA DENGAN ANGKA YANG MUNCUL, MAKA DIGUNAKAN INTERPOLASI LINIER DENGAN RUMUS SEBAGAI BERIKUT:

    (X2 - X) (Y2 - Y1)Y = Y2 - ( ) (X2 - X1)INTERPOLASI LINIERSIS0307

  • FLOW CHART YANG MENJELASKAN VOLUME DAN BERAT YANG BERHUBUNGAN DENGAN FAKTOR KOREKSI DAN KONVERSI.FLOW CHARTSIS0307

  • FLOW CHART YANG MENJELASKAN VOLUME DAN BERAT YANG BERHUBUNGAN DENGAN FAKTOR KOREKSI DAN KONVERSI.FLOW CHARTSIS0307

  • FLOW CHARTSIS0307

  • D1 = (VD - (V2D2 + V3D3)) / V1

    KETERANGAN:D = WET DENSITY.V = WET OIL VOLUME.D1 = DRY DENSITY.D2 = WATER DENSITY.D3 = SEDIMENT DENSITY.V1 = DRY OIL VOLUME. V2 = WATER VOLUME. V3 = SEDIMENT VOLUME. PERITUNGAN DRY DENSITY CATATAN:DRY DENSITY TIDAK UMUM UNTUK BANYAK NEGARA, PORT DAN TERMINAL.SIS0307

  • - TRIMMED BY STERN: AFTERWARD DRAFT DIKURANGI FORWARD DRAFT HASILNYA POSITIF.- TRIMMED BY HEAD: AFTERWARD DRAFT DIKURANGI FORWARD DRAFT HASILNYA NEGATIF.- TABEL KOREKSI TRIM ADA DALAM TABEL KALIBRASI TANKI KAPAL, DIGUNAKAN UNTUK MENGOREKSI DIP ATAU ULLAGE .- KOREKSI TRIM BISA POSITIF ATAU NEGATIF.KOREKSI TRIMSIS0307

  • - LIST BIASANYA DIBACA DARI INCLINOMETER.

    - STATUS DARI LIST : OPORT, JIKA KAPAL CONDONG KE KIRI, OSTARBOARD, JIKA KAPAL CONDONG KE KANAN.

    - TABEL KOREKSI LIST ADA DALAM TABEL KALIBRASI TANKI KAPAL, DIGUNAKAN UNTUK MENGOREKSI DIP ATAU ULLAGE .

    - LIST CORRECTION BISA POSITIF ATAU NEGATIF.KOREKSI LISTSIS0307

  • V = (X2 x W) / 2E

    KETERANGAN:X = ((( U - (D x E)) x E) + SE = TRIM / LBPV = VOLUME DARI OBQ/ROB.W = LEBAR TANKI.S = SOUNDING (LIQUID DIP READING).U = JARAK DIPPING POINT DAN AFT. BULKHEAD.TRIM = AFT. DRAFT - FWD. DRAFT.LBP = PANJANG KAPAL.WEDGE FORMULASIS0307

  • SATUAN DAN TABEL UNTUK PETROLEUMSIS0307

    COSUM T-6

    NO.UNITS / TABLESSYSTEM OF UNITS

    METRICAMERICANBRITISH

    1Linearmm - metresFt - InchFt - Inch

    2TemperatureoCoFoF

    3Pressurebar - kg/cm2psigpsig

    4VolumeLitres - m3Barrels - US GallonsBarrels - Imp. Gallons

    5WeightMetric TonsLong Tons - PoundsLong Tons - Pounds

    6Density CorrectionTable 53A - (53)Table 5A - (5)Table 23A - (23)

    7Density CorrectionTable 51Table 3Table 21

    8Volume CorrectionTable 52Table 4Table 22

    9Volume CorrectionTable 54A - (54)Table 6A - (6)Table 24A - (24)

    10Weight CorrectionTable 56 - 57Table 11 - 13Table 29

    CATATAN:SEMUA KALKULASI DALAM SISTEM YANG BERBEDA HARUSLAH

    KONSISTEN DALAM UNIT DAN TABELNYA.

  • SATUAN DAN TABELUNTUK PRODUK PETROLEUMSIS0307

    CO UNITS

    NO.UNITS / TABLESSYSTEM OF UNITS

    METRICAMERICANBRITISH

    1Linearmm - metresFt - InchFt - Inch

    2TemperatureoCoFoF

    3Pressurebar - kg/cm2psigpsig

    4VolumeLitres - m3Barrels - US GallonsBarrels - Imp. Gallons

    5WeightMetric TonsLong Tons - PoundsLong Tons - Pounds

    6Density CorrectionTable 53B - 53D - (53)Table 5B - 5D - (5)Table 23B - 23D - (23)

    7Density CorrectionTable 51Table 3Table 21

    8Volume CorrectionTable 52Table 4Table 22

    9Volume CorrectionTable 54B - 54D - (54)Table 6B - 6D - (6)Table 24B - 24D - (24)

    10Weight CorrectionTable 56 - 57Table 11 - 13Table 29

    CATATAN:SEMUA KALKULASI DALAM SISTEM YANG BERBEDA HARUSLAH

    KONSISTEN DALAM UNIT DAN TABELNYA.

  • KUANTITAS TANKI DARATSIS0307

    5.bin

  • CONTOH: PERHITUNGAN TANKI DARATSIS0307

    COFLR T-6

    FLOATING ROOFUNITTANK NO. 1301-A

    OPENING (T-6)OPENING (T-6A)REMARKS

    1Reference Heightmm1750717507Tank Cap. Table

    2Measured Heightmm1750517505Measurement

    3ATG / Tank Remotemm1088110881Measurement

    4GAUGE: Oil + Watermm1087710877Measurement

    5GAUGE: Water onlymm00Measurement

    6TemperatureOF90.090.0Measurement

    7Total Observed VolumeBbls370476.70370476.70Tank Cap. Table

    8Free WaterBbls0.000.00Tank Cap. Table

    9CTSh0.99999660.9999966Tank Cap. Table

    10Floating Roof AdjustmentBbls58.5058.50Tank Cap. Table

    11Gross Observed VolumeBbls370533.94370533.94((7-8)x9)+10

    12API40.340.3Analysis Data

    13VCF: Table 6 / 6A0.985770.98484Table-6 / 6A

    14Gross Standard VolumeBbls365261.24364916.6511 x 13

    15WCF: Table 110.128580.12858Table-11

    16Gross Standard WeightLong Tons46965.29046920.98314 x 15

    17S+W % Volume0.050.05Analysis Data

    18S+W VolumeBbls182.63182.4614 x17

    19Net Standard VolumeBbls365078.61364734.1914 -18

    20WCF: Table 110.128580.12858Table-11

    21Net Standard WeightLong Tons46941.80846897.52219 x 20

    COFLR T-6A

    FLOATING ROOFUNITTANK NO. 1301-A

    OPENINGCLOSING

    1Reference Heightmm1750717507

    2Measured Heightmm1750517505

    3ATG / Tank Remotemm108816171

    4GAUGE: Oil + Watermm108776168

    5GAUGE: Water onlymm00

    6TemperatureOF90.088.0

    7Total Gauge VolumeBbls370476.70206842.30

    8Floating Roof CorrectionBbls/+58.5/1.0000070+58.5/1.0000070

    9Total Observed VolumeBbls370537.79206902.25

    10Free WaterBbls0.000.00

    11Gross Observed VolumeBbls370537.79206902.25

    12API40.340.3

    13VCF: Table 6A0.984840.98532

    14Gross Standard VolumeBbls364920.44203864.92

    15GSV DeliveredBbls161055.52

    16WCF: Table 110.128580.12858

    17Gross Standard WeightLong Tons46921.47026212.951

    18GSW DeliveredLong Tons20708.519

    19S+W % Volume0.050.05

    20S+W VolumeBbls182.46101.93

    21Net Standard VolumeBbls364737.98203762.99

    22NSV DeliveredBbls160974.99

    23WCF: Table 110.128580.12858

    24Net Standard WeightLong Tons46898.00926199.845

    25NSW DeliveredLong Tons20698.164

  • CONTOH: PERHITUNGAN TANKI DARATSIS0307

    COFXR T-6

    FIXED ROOFUNITTANK NO. 1301-DREMARKS

    OPENINGCLOSING

    1Reference Heightmm1750717507Tank Cap. Table

    2Measured Heightmm1750517505Measurement

    3ATG / Tank Remotemm108816171Measurement

    4GAUGE: Oil + Watermm108776168Measurement

    5GAUGE: Water onlymm105Measurement

    6TemperatureOF90.088.0Measurement

    7Total Gauge VolumeBbls370476.70206842.30Tank Cap. Table

    8Floating Roof CorrectionBbls/0.000.00Tank Cap. Table

    9Total Observed VolumeBbls370476.70206842.307 +/- 8

    10Free WaterBbls100.0050.00Tank Cap. Table

    11Gross Observed VolumeBbls370376.70206792.309 - 10

    12API40.340.3Analysis Data

    13VCF: Table 60.985770.98674Table-6

    14Gross Standard VolumeBbls365106.24204050.2311 x 13

    15GSV DeliveredBbls161056.01OPEN - CLOSE

    16WCF: Table 110.128580.12858Table-11

    17Gross Standard WeightLong Tons46945.36026236.77914 x 16

    18GSW DeliveredLong Tons20708.581OPEN - CLOSE

    19S+W % Volume0.050.05Analysis Data

    20S+W VolumeBbls182.55102.0314 x19

    21Net Standard VolumeBbls364923.69203948.2014 -20

    22NSV DeliveredBbls160975.49OPEN - CLOSE

    23WCF: Table 110.128580.12858Table-11

    24Net Standard WeightLong Tons46921.88826223.66021 x 23

    25NSW DeliveredLong Tons20698.228OPEN - CLOSE

    COFLR T-6

    FLOATING ROOFUNITTANK NO. 1301-AREMARKS

    OPENINGCLOSING

    1Reference Heightmm1750717507Tank Cap. Table

    2Measured Heightmm1750517505Measurement

    3ATG / Tank Remotemm108816171Measurement

    4GAUGE: Oil + Watermm108776168Measurement

    5GAUGE: Water onlymm00Measurement

    6TemperatureOF90.088.0Measurement

    7Total Observed VolumeBbls370476.70206842.30Tank Cap. Table

    8Free WaterBbls0.000.00Tank Cap. Table

    9CTSh0.99999661.0000348Tank Cap. Table

    10Floating Roof AdjustmentBbls58.5058.50Tank Cap. Table

    11Gross Observed VolumeBbls370533.94206908.00((7-8)x9)+10

    12API40.340.3Analysis Data

    13VCF: Table 60.985770.98674Table-6

    14Gross Standard VolumeBbls365261.24204164.411 x 13

    15GSV DeliveredBbls161096.84OPEN - CLOSE

    16WCF: Table 110.128580.12858Table-11

    17Gross Standard WeightLong Tons46965.29026251.45914 x 16

    18GSW DeliveredLong Tons20713.831OPEN - CLOSE

    19S+W % Volume0.050.05Analysis Data

    20S+W VolumeBbls182.63102.0814 x19

    21Net Standard VolumeBbls365078.61204062.3214 -20

    22NSV DeliveredBbls161016.29OPEN - CLOSE

    23WCF: Table 110.128580.12858Table-11

    24Net Standard WeightLong Tons46941.80826238.33321 x 23

    25NSW DeliveredLong Tons20703.475OPEN - CLOSE

    *

  • CONTOH: PERHITUNGAN TANKI DARATSIS0307

    COFXR T-6

    FIXED ROOFUNITTANK NO. 1301-DREMARKS

    OPENINGCLOSING

    1Reference Heightmm1750717507Tank Cap. Table

    2Measured Heightmm1750517505Measurement

    3ATG / Tank Remotemm108816171Measurement

    4GAUGE: Oil + Watermm108776168Measurement

    5GAUGE: Water onlymm105Measurement

    6TemperatureOF90.088.0Measurement

    7Total Gauge VolumeBbls370476.70206842.30Tank Cap. Table

    8Floating Roof CorrectionBbls/0.000.00Tank Cap. Table

    9Total Observed VolumeBbls370476.70206842.307 +/- 8

    10Free WaterBbls100.0050.00Tank Cap. Table

    11Gross Observed VolumeBbls370376.70206792.309 - 10

    12API40.340.3Analysis Data

    13VCF: Table 60.985770.98674Table-6

    14Gross Standard VolumeBbls365106.24204050.2311 x 13

    15GSV DeliveredBbls161056.01OPEN - CLOSE

    16WCF: Table 110.128580.12858Table-11

    17Gross Standard WeightLong Tons46945.36026236.77914 x 16

    18GSW DeliveredLong Tons20708.581OPEN - CLOSE

    19S+W % Volume0.050.05Analysis Data

    20S+W VolumeBbls182.55102.0314 x19

    21Net Standard VolumeBbls364923.69203948.2014 -20

    22NSV DeliveredBbls160975.49OPEN - CLOSE

    23WCF: Table 110.128580.12858Table-11

    24Net Standard WeightLong Tons46921.88826223.66021 x 23

    25NSW DeliveredLong Tons20698.228OPEN - CLOSE

    COFLR T-6

    FIXED ROOFUNITTANK NO. 1301-DREMARKS

    OPENINGCLOSING

    1Reference Heightmm1750717507Tank Cap. Table

    2Measured Heightmm1750517505Measurement

    3ATG / Tank Remotemm108816171Measurement

    4GAUGE: Oil + Watermm108776168Measurement

    5GAUGE: Water onlymm100Measurement

    6TemperatureOF90.088.0Measurement

    7Total Observed VolumeBbls370476.70206842.30Tank Cap. Table

    8Free WaterBbls100.000.00Tank Cap. Table

    9CTSh0.99999661.0000348Tank Cap. Table

    10Floating Roof AdjustmentBblsn/an/aTank Cap. Table

    11Gross Observed VolumeBbls370375.44206849.50(7-8)x9

    12API40.340.3Analysis Data

    13VCF: Table 60.985770.98674Table-6

    14Gross Standard VolumeBbls365105204106.6811 x 13

    15GSV DeliveredBbls160998.32OPEN - CLOSE

    16WCF: Table 110.128580.12858Table-11

    17Gross Standard WeightLong Tons46945.20126244.03714 x 16

    18GSW DeliveredLong Tons20701.164OPEN - CLOSE

    19S+W % Volume0.050.05Analysis Data

    20S+W VolumeBbls182.55102.0514 x19

    21Net Standard VolumeBbls364922.45204004.6314 -20

    22NSV DeliveredBbls160917.82OPEN - CLOSE

    23WCF: Table 110.128580.12858Table-11

    24Net Standard WeightLong Tons46921.72926230.91521 x 23

    25NSW DeliveredLong Tons20690.814OPEN - CLOSE

  • KUANTITAS TANKI KAPALSIS0307

  • CONTOH: PERHITUNGAN TANKI KAPALSIS0307

    Sheet1

    Fwd Draft= 9.50 mAft Draft= 11.20 m

    SHIP'S TANKS BEFORE LOADINGPort List= 0.00 deg.Stb List= 0.00 deg.

    LBP= 230.50 mSea condition= Calm.

    PARTICULARTANK NO.

    UNIT1P1S2P2S3C

    Distance (U)m0.9860.9860.9860.9860.986

    Depth (D)m8.3208.3208.3208.3208.320

    Sounding (S)m0.0000.0000.0000.0500.100

    Length (L)m22.4522.4522.4522.4522.45

    Trim/LBP (E)0.007380.007380.007380.007380.00738

    Wide (W)m20.34220.34220.34220.34220.342

    X ValuemN/AN/AN/A0.056820.10682

    Y Valuem0.165680.165680.165680.165680.16568

    GOVm30004.44915.726

    Table-1 Factorm3 to bbls6.289816.289816.289816.289816.28981

    GOVbbls00027.9898.91

    GOV Total =126.89bbls

    NOTE: The formula valid if X less than Y.

    X = ((( U - (D x E)) x E ) + S

    E = TRIM / LBP

    GOV = ( X2 x W ) / ( 2E )

    Y = L x E

    TANK NO.XYREMARKS

    2S0.056820.16568X < YWedge Calculation

    3C0.106820.16568X < YWedge Calculation

  • CONTOH: PERHITUNGAN TANKI KAPALSIS0307

    Sheet1

    Fwd Draft= 10..00 mAft Draft= 10.00 m

    SHIP'S TANKS BEFORE LOADINGPort List= 0.00 deg.Stb List= 0.00 deg.

    API= n/aSea condition= Calm.

    PARTICULARTANK NO.

    UNIT1P1S2P2S3C

    Reference Heightmm1905519049188411885118849

    Ullagemm1905519049188411884118844

    Corrected Ullagemm1905519049188411884118844

    TemperatureoFn/an/an/an/an/a

    TOVbbls0.000.000.0040.0022.00

    Free Water Dipmm00000

    Free Water Volumebbls0.000.000.000.000.00

    Liqud Hyd. (Level)mm1905519049188411884118844

    Liqud Hyd. (Volume)bbls0.000.000.0040.0022.00

    Non. Liq. Hyd. (L)mm00000

    Non. Liq. Hyd. (Vol.)bbls0.000.000.000.000.00

    GOV Total =62.00bbls

    FW Total =0.00bbls

    Non Liquid Hydrocarbon Total =0.00bbls

  • CONTOH: PERHITUNGAN TANKI KAPALSIS0307

    Sheet1

    Fwd Draft= 7.10 mAft Draft= 9.70 m

    SHIP'S TANKS AFTER LOADINGPort List= 0.00 deg.Stb List= 0.00 deg.

    API= 40.3Sea condition= Slight.

    PARTICULARTANK NO.

    UNIT1P1S2P2S3C

    Reference Heightmm1905519049188411885118849

    Ullagemm1.531.371.341.371.32

    Corrected Ullagemm1.671.521.491.511.47

    TemperatureoF9696969696

    TOVbbls49973.0010222.00100043.0090968.0049922.00

    Free Water Dipmm00.0100.020

    Free Water Volumebbls0.0040.000.0080.000.00

    GOVbbls49973.0010182.00100043.0090888.0049922.00

    VCF T-60.982940.982940.982940.982940.98294

    GSVbbls49120.4610008.3098336.2789337.4549070.33

    TOV Total =301128.00bbls

    GOV Total =301008.00bbls

    FW Total =120.00bbls

    GSV =295872.81bbls

    Catatan:

    Corrected Ullage diperoleh dari Ullage yang dikoreksi oleh Trim dan List Correction.

  • CONTOH: PERHITUNGAN TANKI KAPALSIS0307

    Sheet1

    SHIP'S TANKSUNITSHIP'S TANK NO.: 1P, 1S, 2P, 2S, 3CREMARKS

    SUMMARY AT LOADINGB/ LOADINGA/ LOADING

    1APIN/A40.3Analysisi Data

    2Gross Standard VolumeBbls62.00295872.81Calculation

    3GSV LoadedBbls295810.81After - Before

    4WCF: Table 110.128580.12858Table-11

    5Gross Standard WeightLong Tons7.97238043.3262 x 4

    6GSW LoadedLong Tons38035.35After - Before

    7S+W % VolumeN/A0.05Analysisi Data

    8S+W VolumeBblsN/A147.942 x 7

    9Net Standard VolumeBbls62.00295724.872 - 8

    10NSV LoadedBbls295662.87After - Before

    11WCF: Table 110.128580.12858Table-11

    12Net Standard WeightLong Tons7.97238024.3049 x 11

    13NSW LoadedLong Tons38016.33After - Before

    Assumption :GOV Before Loading as GSV.

    WCF Before Loading same as A/Loading.

    *