PERBANDINGAN KUALITAS CITRA SINGLE-SHOT FAST SPIN …repository.unair.ac.id/96166/10/10. DAFTAR...
Transcript of PERBANDINGAN KUALITAS CITRA SINGLE-SHOT FAST SPIN …repository.unair.ac.id/96166/10/10. DAFTAR...
47
DAFTAR PUSTAKA
Abhisek, Agrawal, 2012, Additional Merits of Two- Dimensional Single Thick-
Slice Magnetic Resonance Myelography in Spinal Imaging : US National
Library of Medicine National of Health New York.
Abubakar. 2005. Diagnostik Radiologik Pada Kelainan Kolumna Vertebralis, PT
Gramedia: Jakarta.
Arikunto. 2006. Prosedur Penelitian Suatu Pendekatan Praktek. Jakarta : PT.
Rineka Cipta.
Bitar,R.,Leung,G.,Perng,R., Tadros,S., Moody,A. R.,Sarrazin,J.,dan Roberts,T.P,
2006, MR Pulse Sequences:what every radiologist wants to know but is afraid
to know ask, Radiographics.
Burghart, Geraldine and Carol Finn, 2011, Handbook of MRI scanning . Elsevier
Mosby. St. Louis, Missouri.
Elmaoglu, Muhammed and Celik, 2012, MRI Handbook : MR Physics, Patient
Positioning and Protocols Spinger : Germany.
Fauzia Andini ,2015, Risk Factors of Low Back Pain in Workers ,Faculty of
Medicine Universitas Lampung.
Hines Tonya, 2016, Mayfield Brain and Spine (Anatomy of the Spine), Mayfield
Clinic.
McRobbie, Donald W, et all, 2006, MRI From Picture to Proton ,Second Edition
:Cambride University Press : New York.
IR - PERPUSTAKAAN UNIVERSITAS AIRLANGGA
SKRIPSI PERBANDINGAN KUALITAS CITRA... AGITHIA RAHMA KUSUMA W
48
Morgan GE, Mikhail MS, Murray MJ. Chronic Pain Managament. In : Clinical
Anesthesiology, 5th ed. Lange Medical Books/McGraw-Hill, 2013, p. 1023-
85.
MRI Master, 2018, HASTE (Half-Fourier-Acquired Single-Shot Turbo spin
Echo),diakses pada tanggal 25 Maret 2019.
Muhaimin, Lailatul Muqmiroh, Risalatul Latifah, Amillia Kartikasari, Anggraini
Sensusiati,2019, Pulse Sequence Single Shot Fast Spin Echo for Reducing
Motion Artefact on MRI of the Brain. Malaysian Journal of Medicine and
Health Sciences
Mulyono Notosiswoyo & Susy Suswati, 2004, Pemanfaatan Magnetic Resonance
Imaging (Mri) Sebagai Sarana Diagnosa Pasien, Media Litbang Kesehatan.
Patel, Mahesh , 2000, Half-Fourier Acquisition Single-Shot Turbo Spin Echo
(HASTE) MR : Comparison with Fast Spin-Echo Mr. in Diseases of theBrain.
Snell, R. S. 2012. Anatomi Klinis Berdasarkan Sistem. Dialih bahasakan oleh
Sugarto L. Jakarta:EGC.
Snell Richard S, 2012, Clinical Anatomy By Regions Edition 9, Library of
Congress Cataloging in Publication Data.
Sugiyono,2010,Metode Penelitian Pendidikan Pendekatan Kuantitatif, kualitatif,
dan R&D. Bandung: Alfabeta
Suprapti, 2006, Pengaruh Variasi TR Terhadap Informasi Citra Pada Pencitraan
Myelografi Coronal Magnetic Resonance Imaging (MRI) 0.5 T RSU
IR - PERPUSTAKAAN UNIVERSITAS AIRLANGGA
SKRIPSI PERBANDINGAN KUALITAS CITRA... AGITHIA RAHMA KUSUMA W
49
Dr.Soetomo Surabaya, KTI Diploma IV Teknik Radiologi Jurusan Teknik
Radiodiagnostik dan Radioterapi Poltekkes Kemenkes Semarang.
Westbrook,C dan Kauth Rooth Carolyn, 1999. frekuensi presesi Magnetic
Resonance Imaging. Schoarpedia.
Westbrook Cathrine, ,Talbot John, 2011, Handbook of MRI Practice. Third edition
Willey-Blackwell : Cambrige, UK.
Westbrook Cathrine, 2014, Hanbook of MRI Technique Fourth Edition,Wiley
Blackwell, Department of Allied Health and Medicine : Cambridge,UK.
Weishaupt, Dominik, Viktor D Kochli, Borut Maricek, 2006, How Does MRI
Work?, Spinger : Germany.
Yamashita, Y. et al., 1998. Comparison of Ultrafast Half-Fourier Single Shot Turbo
Spin-Echo Sequence with Turbo Spin-Echo Sequences for T2-Weighted
Imaging of the Female Pelvis. Journal of Magnetic Resonance Imaging,
Volume VIII, pp. 1207-1212.
Yu, J.-S., Kim, K. W., Kim, Y. H., Jeong, E.-K., & Chien, D. (1998). Comparison
of multishot turbo Spin Echo and HASTE sequences for T2-weighted MRI of
liver lesions. Journal of Magnetic Resonance Imaging, 8(5), 1079–
1084.doi:10.1002/jmri.1880080512.
IR - PERPUSTAKAAN UNIVERSITAS AIRLANGGA
SKRIPSI PERBANDINGAN KUALITAS CITRA... AGITHIA RAHMA KUSUMA W
50
Lampiran 1. Kuesioner Penilaian
Kuisioner Penilaian Kualitas Citra Single-Shot FSE dan Multi-shot FSE MR
Myelography Lumbal
Sekuen Kriteria Kualitas Citra Penilaian
1 2 3 4
Single-shot
Fast Spin
Echo
Ketampakan Artefak
Ketajaman Lesi
Diagnostic Confidence
Noise
Multi-shot
Fast Spin
Echo
Ketampakan Artefak
Ketajaman Lesi
Diagnostic Confidence
Noise
Tabel penilaian tersebuat menggunakan teknik scoring dan
mengguanakan score 1 sampai dengan 4 untuk memberikan penilaian
pada kualitas citra Single-Shot FSE dan Multi-shot FSE MR
Myelography Lumbal. Berikut petunjuk pengisian kuisioner:
1. Ketampakan Artefak
Penilaian pertama yaitu artefak yang ditimbulkan dengan memberikan nilai:
a. Score 1 = seluruh gambaran Myelography terganggu oleh adanya
artefak.
b. Score 2 = terdapat artefak yang menutupi 75% gambaran Myelography.
c. Score 3 = terdapat artefak yang menutupi 50% gambaran Myelography.
d. Score 4 = tidak terdapat artefak yang mengganggu gambaran
Myelography.
IR - PERPUSTAKAAN UNIVERSITAS AIRLANGGA
SKRIPSI PERBANDINGAN KUALITAS CITRA... AGITHIA RAHMA KUSUMA W
51
2. Ketajaman Lesi
Penilaian ke-dua yaitu ketajaman lesi yang ditimbulkan dengan
memberikan nilai:
a. Score 1 = lesi dan jaringan sekitarnya tidak dapat dibedakan.
b. Score 2= lesi dan jaringan sekitar sebagian kecil dapat dibedakan.
c. Score 3= lesi dan jaringan sekitar sebagian besar dapat dibedakan.
d. Score 4= lesi dan jaringan sekitar dapat dibedakan dengan mudah.
3. Diagnostic Confidence
Penilaian ke-tiga yaitu Diagnostic Confidence yang ditimbulkan dengan
memberikan nilai:
a. Score 1 = Tidak memberikan informasi apapun.
b. Score 2= Tidak memberikan informasi dan tidak penting untuk
diagnosa.
c. Score 3= Memberikan sedikit informasi tetapi tidak penting untuk
diagnosa.
d. Score 4= Memberikan infomasi yang penting untuk diagnosa.
4. Noise
Penilaian ke-tiga yaitu Noise yang ditimbulkan dengan memberikan nilai:
a. Score 1 = seluruh gambaran Myelography terganggu oleh adanya
Noise.
b. Score 2 = terdapat Noise yang menutupi 75% gambaran Myelography.
c. Score 3 = terdapat Noise yang menutupi 50% gambaran Myelography.
d. Score 4 = tidak terdapat Noise yang mengganggu gambaran
Myelography.
IR - PERPUSTAKAAN UNIVERSITAS AIRLANGGA
SKRIPSI PERBANDINGAN KUALITAS CITRA... AGITHIA RAHMA KUSUMA W
52
Lampiran 2. Output SPSS
(a) Uji Wilcoxon Sign Rank Test
Test Statisticsa
Struktur Anatomi
Z -1,667b
Asymp. Sig. (2-tailed) ,096
a. Wilcoxon Signed Ranks Test
b. Based on negative ranks.
Test Statisticsa
Ketampakan
Artefak
Z -2,490b
Asymp. Sig. (2-tailed) ,013
a. Wilcoxon Signed Ranks Test
b. Based on positive ranks.
Test Statisticsa
Diagnosis
Confidence
Z -,707b
Asymp. Sig. (2-tailed) ,480
a. Wilcoxon Signed Ranks Test
b. Based on negative ranks.
Test Statisticsa
Noise
Z -3,051b
Asymp. Sig. (2-tailed) ,002
a. Wilcoxon Signed Ranks Test
b. Based on negative ranks.
IR - PERPUSTAKAAN UNIVERSITAS AIRLANGGA
SKRIPSI PERBANDINGAN KUALITAS CITRA... AGITHIA RAHMA KUSUMA W
53
(b) Nilai Mean,Standar Deviasi, Minimum,dan Maximum
Statistics
Ketampakan
Artefak SSH
Ketampakan
Artefak MSH
Struktur
Antomi SSH
Struktur Antomi
MSH
Diagnosis
Confidence
SSH
Diagnosis
Confidence
MSH
Noise
SSH Noise MSH
N Valid 16 16 16 16 16 16 16 16
Missing 0 0 0 0 0 0 0 0
Mean 3,8125 3,2500 3,7188 3,8750 3,7500 3,8125 3,2813 3,6250
Std. Deviation ,25000 ,60553 ,40697 ,38730 ,25820 ,40311 ,25617 ,22361
Range ,50 ,50 1,00 1,50 ,50 1,50 ,50 ,50
Minimum 3,50 3,50 3,00 2,50 3,50 2,50 3,00 3,50
Maximum 4,00 4,00 4,00 4,00 4,00 4,00 3,50 4,00
IR - PERPUSTAKAAN UNIVERSITAS AIRLANGGA
SKRIPSI PERBANDINGAN KUALITAS CITRA... AGITHIA RAHMA KUSUMA W
54
Lampiran 3. Hasil Citra Single-Shot Fast Spin Echo dan Multi-Shot Fast Spin
Echo
MSH SSH
MSH SSH
SSH MSH
IR - PERPUSTAKAAN UNIVERSITAS AIRLANGGA
SKRIPSI PERBANDINGAN KUALITAS CITRA... AGITHIA RAHMA KUSUMA W
55
SSH MSH
SSH MSH
SSH MSH
IR - PERPUSTAKAAN UNIVERSITAS AIRLANGGA
SKRIPSI PERBANDINGAN KUALITAS CITRA... AGITHIA RAHMA KUSUMA W
56
SSH MSH
SSH MSH
SSH MSH
IR - PERPUSTAKAAN UNIVERSITAS AIRLANGGA
SKRIPSI PERBANDINGAN KUALITAS CITRA... AGITHIA RAHMA KUSUMA W
57
SSH MSH
SSH MSH
SSH MSH
IR - PERPUSTAKAAN UNIVERSITAS AIRLANGGA
SKRIPSI PERBANDINGAN KUALITAS CITRA... AGITHIA RAHMA KUSUMA W
58
SSH MSH
SSH MSH
SSH MSH
IR - PERPUSTAKAAN UNIVERSITAS AIRLANGGA
SKRIPSI PERBANDINGAN KUALITAS CITRA... AGITHIA RAHMA KUSUMA W
59
SSH MSH
IR - PERPUSTAKAAN UNIVERSITAS AIRLANGGA
SKRIPSI PERBANDINGAN KUALITAS CITRA... AGITHIA RAHMA KUSUMA W
60
Lampiran 4. Form Persetujuan Sampel Penelitian
PENJELASAN UNTUK MENGIKUTI PENELITIAN
1. Saya adalah Mahasiswa Jurusan Teknologi Radiologi Pencitraan dengan ini meminta anda untuk berpartisipasi dengan sukarela dalam penelitian yang berjudul “Perbandingan Kualitas Citra Single-Shot Fast Spin Echo dan Multi-Shot Fast Spin Echo MR Myelography Lumbal”.
2. Tujuan dari penelitian ini untuk Mengetahui perbandingan kualitas citra dari pulse sekuen Single-shot fast spin echo dan Multi-shot fast spin echo pada MR Myelography Lumbal secara kualitatif yang akan diambil sesuai dengan kriteria inklusi dan eksklusi yang telah ditetapkan peneliti.
3. Prosedur pengambilan sample sesuai kriteria inklusi dan eksklusi, dimulai dengan memberikan informed consent kepada pasien, kemudian pasien yang bersedia akan dilakukan Pemeriksaan MRI Lumbal sesuai prosedur dengan sekuen MR Myelography Lumbal dengan dua kali pemeriksaan dengan pulse sekuen Single-shot fast spin echo dan Multi-shot fast spin echo. Penelitian ini tidak memiliki efek samping.
4. Keuntungan yang anda peroleh dalam keikutsertaan anda adalah mendapatkan diagnosa yang maksimal dari perbandingan pulse sekuens tersebut.
5. Seandainya anda tidak menyetujui cara ini maka anda dapat memilih atau anda boleh tidak mengikuti penelitian ini sama sekali, dan tidak akan mempengaruhi pelayanan rumah sakit terhadap anda.
6. Nama dan jati diri anda akan tetap dirahasiakan 7. Keputusan ini dibuat pasien setelah menerima penjelasan dari peneliti. 8. Tanda terima kasih kepada subjek 9. Biaya pemeriksaan tambahan ditanggung oleh siapa? Tidak ada biaya
tambahan untuk pemeriksaan PENELITI
(AGITHIA RAHMA KUSUMA WARDHANI )
RUMAH SAKIT UMUM DAERAH Dr SAIFUL ANWAR
Jl. Jaksa agung Suprapto No.2 Malang
KOMISI ETIK PENELITIAN KESEHATAN
IR - PERPUSTAKAAN UNIVERSITAS AIRLANGGA
SKRIPSI PERBANDINGAN KUALITAS CITRA... AGITHIA RAHMA KUSUMA W
61
PERNYATAAN PERSETUJUAN UNTUK
BERPARTISIPASI DALAM PENELITIAN
Saya yang bertanda tangan dibawah ini menyatakan bahwa:
1. Saya telah mengerti tentang apa yang tercantum dalam lembar penjelasan diatas dan telah dijelaskan oleh peneliti
2. Dengan ini saya menyatakan bahwa secara sukarela bersedia / tidak bersedia *) untuk ikut serta menjadi salah satu subjek penelitian yang berjudul ”Perbandingan Kualitas Citra Single-Shot Fast Spin Echo dan Multi-Shot Fast Spin Echo MR Myelography Lumbal”
Malang, ……………..2019
Peneliti Saksi 1 Yangmembuat pernyataan
(Agithia Rahma Kusuma W) (…………………………)(……………………………)
NIM.151510383007
Saksi 2
(.................................)
*) Coret salah satu
RUMAH SAKIT UMUM DAERAH Dr SAIFUL ANWAR
Jl. Jaksa agung Suprapto No.2 Malang
KOMISI ETIK PENELITIAN KESEHATAN
IR - PERPUSTAKAAN UNIVERSITAS AIRLANGGA
SKRIPSI PERBANDINGAN KUALITAS CITRA... AGITHIA RAHMA KUSUMA W
62
Lampiran 5. Data Kuisioner
NO JK USIA
KETAMPAKAN ARTEFAK STRUKTUR ANATOMI DIAGNOSTIC CONFIDENCE NOISE
SINGLE-SHOT MULTI-SHOT SINGLE-SHOT MULTI-SHOT SINGLE-SHOT MULTI-SHOT SINGLE-SHOT MULTI-SHOT
R1 R2 MEAN R1 R2 MEAN R1 R2 MEAN R1 R2 MEAN R1 R2 MEAN R1 R2 MEAN R1 R2 MEAN R1 R2 MEAN
1 P 53 4 4 4 4 3 3,5 4 2 3 4 3 3,5 4 4 4 4 4 4 3 4 3,5 4 4 4
2 L 67 4 4 4 3 4 3,5 4 4 4 4 4 4 4 4 4 4 4 4 3 4 3,5 3 4 3,5
3 P 58 4 4 4 4 3 3,5 3 3 3 3 2 2,5 3 4 3,5 3 2 2,5 3 4 3,5 3 4 3,5
4 P 63 3 4 3,5 2 4 3 4 4 4 4 4 4 4 4 4 4 4 4 3 3 3 3 4 3,5
5 P 63 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 3 4 3,5 4 4 4
6 P 34 4 4 4 3 2 2,5 3 4 3,5 4 4 4 3 4 3,5 4 4 4 3 4 3,5 3 4 3,5
7 L 64 3 4 3,5 4 4 4 3 3 3 4 4 4 4 3 3,5 4 4 4 3 4 3,5 3 4 3,5
8 P 34 3 4 3,5 3 4 3,5 4 4 4 4 4 4 4 4 4 4 4 4 3 4 3,5 3 4 3,5
9 L 22 4 4 4 2 2 2 4 4 4 4 4 4 4 4 4 4 4 4 3 3 3 3 4 3,5
10 L 25 3 4 3,5 3 4 3,5 4 4 4 4 4 4 4 4 4 4 4 4 3 4 3,5 3 4 3,5
11 P 53 4 4 4 4 3 3,5 4 4 4 4 4 4 3 4 3,5 3 4 3,5 3 3 3 3 4 3,5
12 L 22 4 4 4 2 3 2,5 4 4 4 4 4 4 4 4 4 4 4 4 3 3 3 3 4 3,5
13 L 25 4 4 4 3 3 3 3 4 3,5 4 4 4 3 4 3,5 3 4 3,5 3 3 3 3 4 3,5
14 P 53 4 4 4 2 3 2,5 4 4 4 4 4 4 3 4 3,5 3 4 3,5 3 3 3 4 4 4
15 L 52 3 4 3,5 4 3 3,5 3 4 3,5 4 4 4 3 4 3,5 4 4 4 3 3 3 3 4 3,5
16 L 17 3 4 3,5 4 4 4 4 4 4 4 4 4 3 4 3,5 4 4 4 3 4 3,5 4 4 4
IR - PERPUSTAKAAN UNIVERSITAS AIRLANGGA
SKRIPSI PERBANDINGAN KUALITAS CITRA... AGITHIA RAHMA KUSUMA W