Pellet Stove T300P Tech Manual

download Pellet Stove T300P Tech Manual

of 29

description

a tech manual to better analyze and fix a problem with you T300p wood pellet stove

Transcript of Pellet Stove T300P Tech Manual

  • Lennox Hearth Products; 1110 West Taft Avenue; Orange, CA 92865 Rev D 8/10/2001

    Lennox Hearth Products 2001

  • Revision D 8/10/20001

    2

    Table of Contents Introduction 3 Tool Supplies 4 Specifications 5

    Cascade Profile 20 Profile 30 - Series Traditions

    Wiring Diagrams 6 Feed System / Operation 7 - 8 Pellet Fuel 9 Power Supply 10 Wiring Harness Igniter Thermostat Control Boards 11 - 12 Model Specific Plug Connections Calibrating Photo Eye Slot 13 Combustion Air Supply 14 Convection Air Supply 15 Safety Systems 16 - 18 Pressure Switches High Limit Switches Low Limit switch (Cascade) Photo-eye Door Switch (Profile 30 series) Question & Answers 19 - 20 Troubleshooting Chart 21

    Maintenance Requirements 22 - 23 Replacement Parts Lists 24 - 28 Technical Bulletins / Updates / Codes / Approvals 29 Upgrade Instructions (Profile20, Profile 30, Traditions Addendums

  • Revision D 8/10/20001

    3

    Introduction

    The Traditions line is a metal firebox housed within a cast body.

    There are three-baked porcelain enamel styles. They are Mojave Sand, Hunter Green, and Ebony Black. A fourth model is painted black cast.

    There are two motors for air movement, the combustion motor and convection motor.

    The upper Hob, or top of the appliance, directs convection air down to the hearth.

    These all come with legs and are fully automatic, standard equipped with thermostat and wire.

    There are ash slides and an ash drawer. A damper control handle is located behind the ash drawer on the right side facing the appliance.

    The Profile 20 & 30 product lines, as well as the Cascade model, are sheet metal in construction. The Profile 20 & 30 models contain a separate motor for combustion and convection air movement. The Cascade has one motor that drives two fans on a single shaft. All models are top feed, negative pressure combustion units. The Cascade has legs, while the Profile 20 & 30 freestanding models are on a pedestal. Each model contains ash slides and an ash drawer. The Profile 20 & 30 models are fully automatic and come standard with a thermostat and wire.

  • Revision D 8/10/20001

    4

    Tool Supplies / Part List

    The provided list of tools is recommended for any Pellet Appliance serviceman to carry. Using the proper tool for the job ensures sounder success.

    Hand Tools:

    Allen Wrench set Stop Watch 12 Tape Measure Straight-tip Screwdriver

    o Narrow tip (#1) o Large tip (#2) o Stubby (#2)

    Torpedo Level Tin Snips Raw Hide Mallet Needle Nose Pliers Open/Box End Wrench Set

    o to 5/8 Outlet Circuit Tester Utility Knife Small Flashlight 1/4 Ratchet Socket Set Phillips Screwdrivers

    o #1 tip o #2 tip

    Plumb Bob Wire Cutters Fuse Extractor Pliers 2 Paint Brush 6 Vise Grips Pocket Knife Crescent Wrench

    o 6 o 10

    Specialty tools remove the guess work and results in quality, accurate results.

    Specialty Tools:

    1. 1 Magnehelic Gauge Kit 2. Multi-meter (reading)

    a. Ohms / Continuity b. Amps c. AC / DC Voltage

    3. Combustible Gas Detector 4. Air Flow Meter 5. Temperature Gauge Kit

    A Drop Cloth provides a professional look and makes the clean-up after a job so much easier. Time is money.

    Parts: Each job will require different spare or replacement parts. Review the Replacement Parts list in the back of this guide and plan accordingly. All servicemen should, at a minimum, carry Category #1 parts in their vehicle.

  • Revision D 8/10/20001

    5

    Specifications

    Cascade: (EPA Exempt) Dimensions: Width 23 Depth 22 5/8 Height 28 Weight: 200Lbs. Hopper Capacity: 60 Lbs. Burn Time: 12 40 Hrs. Flue Connection: 3 Heating Capacity: 1,500 1,800 Sq. Ft. MOBILE HOME APPROVED

    Profile 20: (EPA Exempt) Dimensions: Width 22 Depth 22 Height 28 5/8 Weight: 215Lbs. Hopper Capacity: 55 Lbs. Burn Time: 15 37 Hrs. Flue Connection: 3 Heating Capacity: 1,500 1,800 Sq. Ft. MOBILE HOME APPROVED

    Profile 30: (EPA Certified) Free Standing Model Insert Model Dimensions: Dimensions: Width 25 7/8 Width: Back w/o shroud - 24 1/8 Depth 24 7/8 Depth: Overall - 26 Height 31 3/8 Height: Back w/o shroud 19 15/16

    Weight: 270Lbs. Hopper Capacity: 80 Lbs. Hopper Capacity: 50 Lbs. Burn Time: 18 48 Hrs. Burn Time: 10 45 Hrs.

    Flue Connection: 3 Heating Capacity: 1,800 2,000 Sq. Ft.

    Traditions: (EPA Exempt) Dimensions: Width 28 Depth 29 Height 28 Weight: 285 Lbs. Hopper Capacity: 50 Lbs. Burn Time: 12 40 Hrs. Flue Connection: 3 Heating Capacity: 1,800 2,000 Sq. Ft. MOBILE HOME APPROVED

  • Revision D 8/10/20001

    6

    Wiring Diagrams

    Cascade Model

    Profile Series / Traditions Models

    The switch conditions are shown at room temperature and the stove is in the OFF position. LOW LIMIT Normally open HIGH LIMIT Normally closed VACUUM SWITCH Normally open NOTE: There is no availability for a thermostat connection or for an igniter.

  • Revision D 8/10/20001

    7

    Feed System / Operation

    Top feed system Fuel travel up Auger tube & drops down

    feed chute to burn grate.

    Positive separation of fire and fuel source

    Easy access to clear auger tube jam Built to standards of ASTM E1509

    System component replacement parts: Auger Motor: PN 12046300 End Plate Gasket: PN 61050003 (5ea) Auger Collar & Screw set: PN 12041300

    (3ea)

    The Auger motor is rated at 120 V.A.C. 60 Hz. Its speed rating is 1 RPM with 87 in-Lbs. Starting torque is 118 in-Lbs minimum with a 126 in-Lb average. The minimum breakdown torque is 200 in-Lbs. with a continuous duty cycle. The coil is impedance protected. The motor has an Ohms resistance rating of 17.99 Ohms and Amperage of .55 maximum.

    All pellet appliances use the patented Ultra Grate. This design allows maximum air delivery to the fuel load for combustion through a series of stainless steel bars at the bottom of the grate. Secondary air holes located on the front and rear face direct flame vertical. A single large hole is provided for the Igniter airflow during start-up.

    NOTE: The Cascade model does not have an igniter yet the Large hole is present in the grate. This permits common part usage in pellet products.

  • Revision D 8/10/20001

    8

    Feed System / Operation

    FUEL DELIVERY RATES: The power ON/OFF Time is determined by the selected feed setting on the control board. The auger motor is supplied shots of electricity and the auger shaft moves fuel toward the grate for combustion.

    CASCADE On/Off Lbs /hr* BTU/hr** Burn Time***

    Low 1 / 5.5 1.3 13,000 45 hrs High 1 / 1.15 4.3 39,000 14 hrs

    PROFILE 20

    Low 1 / 5.4 1.5 13,000 37 hrs Med. 1 / 3.3 2.5 21,000 22 hrs High 1 / 1.75 3.8 32,000 15 hrs

    PROFILE 30 Freestanding

    Low 1 / 4.5 1.7 14,000 48 hrs Med. 1 / 1.9 2.6 22,000 30 hrs High 1 / 1.15 4.5 39,000 18 hrs

    Profile 30 Insert

    Low 1 / 4.5 1.7 14,000 30 hrs Med. 1 / 1.9 2.6 22,000 20 hrs High 1 / 1.15 4.5 39,000 12 hrs

    TRADITIONS

    Low 1 / 5.0 1.5 12,000 34 hrs Med. 1 / 3.3 2.5 21,000 20 hrs High 1 / 1.6 3.8 32,000 14 hrs

    * Lbs per hour shown is based on factory settings. Calibrations will vary rates.

    ** BTUs vary with pellet type *** The burn time will vary with size and type of fuel being used.

    All fuel differs in make up because of the raw stock available to each fuel manufacturer. Soft woods and hardwoods not only have various burn characteristics, but they feed through the stoves with slightly different traits. Feed trim adjustments are incorporated on all control boards to compensate for these traits in fuel types.

    The chart below depicts the average feed rate for base fuel of each model at each predetermined setting of the control board. The operator when different fuels do not fall within these ratings can supplement Trim. Remember, as a rule of thumb, Long fuel feed slowly while short fuel feeds fast and heavy fuel feeds fast while light fuel feeds slowly.

  • Revision D 8/10/20001

    9

    Pellet Fuel

    PELLET FUEL INSTITUTE Standards for Pellet Fuel: Heat Content: 8200 BTU/Lb. Min. Bulk Density: 40 Lb. per Cubic Ft. Min. Moisture Content: 8% Max. Ash Content: 1% Max. (PREMIUM)

    3% Max. (STANDARD) Size: 0.23 to 0.35 in diameter

    1.5 inches long Maximum Fines: .5% Max. (Passed through 1/8th in screen)

    The Cascade, Profile series, and Traditions Pellet Stoves can burn most pellets that meet the PFI Premium or Standard Fuel criteria. Ash fusion, or clinkering, is also an important fuel parameter. This is not addressed in the PFI Standards. Clinkering is a low-grade glass making process whereby the silica in the ash softens at temperature and then solidifies on cooling as a clinker and blocks off the primary combustion air holes in the grate. The fire will then burn very rich and soot up the firebox and window rapidly. A clinker can be easily removed using the grate scraper tool. Lift the clinker up and out of the grate and deposit it in the ash pan when cleaning the stove. The clinkering characteristics of the fuel depend on the silica content of the non-combustible ash and the quantities of the trace elements of sodium and potassium (salts), which significantly reduce the melting point of the silica. A fuel that meets the PFI Standard may possibly have poor clinkering characteristics, which would make it an unsuitable fuel for this stove. Care must be taken in recommending suitable fuels to customers, or advising customers of how and when to remove the clinkers.

    All stove models are equipped with the Ultra Grate system and may burn Standard grade fuel with up to 3% ash content. Although the Ultra Grate allows the burning of such lower grade/high ash fuels; such as paper, cardboard, corn and other agricultural fuels, their use should be avoided. LENNOX Hearth Products recommends Premium Grade.

    (The use of low grade fuel will void the stove warranty)

    Each model appliance is equipped with a damper control to adjust for ash build-up during long-term operation. This is a temporary fix. Proper air to fuel ratio is electronically controlled by the software within the control panel. Still adjustments, both electronically and manually may be required to dial in combustion air. Refer to Owners manual for proper damper settings. Remember to close ash slides during appliance operation as well. A leak in this area severely depletes combustion air from being matched with fuel delivery. Heavy ash deposit on the glass is a tell-tale sign of improper air to fuel ratio.

    AIR to Fuel RATIO

  • Revision D 8/10/20001

    10

    Power Supply

    The LENNOX Hearth Products pellet appliance line will not operate using natural draft, or without a source of power for the blower and fuel feed systems. These appliances are rated for 120 V.A.C. at 60 Hz. An 8 Ft. UL approved power cord is provided with each product. Extension cords should be avoided. The appliance amperage draw will differ between models. Having the appliance on its own house circuit insures proper power delivery at all times power is available. Testing has proven the use of supplemental power to be acceptable. All models are generator and inverter capable. The amount of wattage required will depend on the amperage draw of each model. When using an inverter, the reserve battery size will determine the length of power supply available. When using a generator, a secondary power draw attached to the generator will stabilize the power output to the appliance and prevent unforeseen problems.

    In the Profile and Traditions models when power is applied to the stove, for example, when it is plugged into the wall socket, or after a power outage, the control board will start a 3-second timer. During this time, no visual indication that the stove has been powered up will show!

    This allows the power source to stabilize.

    The Cascade will properly respond to power when the Heat control is positioned to High or Low. If it does not, check for a bad fuse or plug connection.

    If the Cascade fans start when unit is plugged in, check for a bad low limit switch.

    The Profile and Traditions control boards contain a memory. These appliances will resume operation in whatever state they were in before power was removed.

    Igniter Probe

    PN: 12150213

    400 Watt 4.8 AMP Runs during Start up Mode Use Fast Blow Inline Fuse

    5/16 hex head threaded connection

    Power Cord PN 12058820 8 Ft.

    All LENNOX Hearth Products pellet stove appliances are Mobile home approved. Special requirements for such applications are an outside air supply, grounding the unit to the homes chassis, and securing the appliance to the homes floor / foundation. Ref: HUD

  • Revision D 8/10/20001

    11

    Control Boards

    CASCADE (PN 17150027)

    PROFILE 20 (PN 16053941) PROFILE 30 Freestanding & Insert (PN 16052112) TRADITIONS (PN 16055150)

    BLOWER SELECT

    HEAT SELECT

    START

    ACCESS DOOR

    FAULT LED

    Start-up Sequence of Events: Rev C

    1. Fault Time Delay is initiated. (14 minutes 15 seconds) 2. Fuel Feed rate of 100% for 1min 50sec

    (when trim left at factory setting of 0) auger trim setting ranges from 1:26 to 2:14 depending on -4 to +4 respectively

    3. Combustion Fan Operation starts (medium range voltage)

    4. Convection Fan Operation starts (medium range voltage)

    6. Power LED is activated (steady green) 7. Igniter Operation activated (line voltage) 8. Photo eye looks for flame (flame

    dominance scheme) 9. * If needed second & third fuel dumps

    are available at predetermined time deliveries. (4 min & 6 min after initial)

    The simplified SSAC control board that is used with the Cascade model only contains a three position Slide Switch and a fuel trim pot. There is an 8 AMP fast blow fuse located on the rear of the circuit board. With the slide switch in the OFF position the stove will not operate. The LOW position sets the auger duty cycle and blower speed to low. On HIGH both systems advance to high. The trim adjustment compensates for fuel differences. Factory set ON time is 1.9 sec. The trim range is 1.6 to 4.5 sec. Factory OFF time for low is fixed at 4.2 sec and for high its fixed at 1.15 sec. The LED is energized whenever the auger motor circuit has power.

    Power will remain on with a hot stove when the slide switch is set to OFF for 25 min (+/- 5 min)

  • Revision D 8/10/20001

    12

    Fuel Feed Trim Steps: Rev C 1. Push button once to access fuel feed calibration

    mode. 2. Identify the current calibration setting indicated by

    one RED LED bar and the word AUGER in red below heat control button

    3. Push the HEAT control button to adjust setting UP. Each push raises the RED LED bar and increases feed rate.

    4. Push the BLOWER control button to adjust setting DOWN. Each push will drop the RED LED bar decreasing feed rate.

    5. Push the calibration button two more times to lock in selected setting.

    Combustion Voltage Trim Steps: Rev C 1. Push button twice for access voltage calibration

    mode. 2. Identify the current calibration setting indicated by

    one YELLOW LED bar. 3. Push the HEAT control button to adjust setting

    UP. Each push raises the YELLOW LED bar & increases voltage 5%.

    4. Push the BLOWER control button to adjust setting DOWN. Each push lowers YELLOW LED bar decreasing voltage 5%.

    5. Push the calibration button once to lock in selected results.

    Calibration is the function of internal software and should be done by a qualified technician. Access to perform Calibration is behind the lower door located on the face of the control panel. Use a penknife to pop open door. Voltage access ports for all circuits are located here as well.

    CALIBRATING FUEL FEED & COMBUSTION VOLTAGE

    PLUG CONNECTIONS

    FUSE

    PHOTO-EYE

    MAIN HARNESS

    POWER SELECT

    PN LABEL LOCATION

    Flame detection Sequence of Events: Happens within the Start-up Time Delay sequence. 0 to 1 minute no fuel feed

    Flame settles Bed of embers built. 1 min mark: Fuel Feed rate 20% for 4min 15 sec

    2 min mark: Igniter turns OFF

    Convection Fan = panel setting5 min 15 sec mark: Combustion Fan = panel settingLED indicator still active

    Start-up Time delay ends 14 minutes 15 seconds after pushing the start button!

  • Revision D 8/10/20001

    13

    PHOTO EYE SLOT

    IIggnniittiioonn SSttaarrtt--uupp YES FLAME (Before 5 min 15 sec mark)

    Activates 1 minute settling timer (allow flame to stabilize / establish bed of embers)

    DDeellaayyeedd IIggnniittiioonn SSttaarrtt--uupp SSeeqquueennccee:: NO FLAME (After 5 min 50 sec mark)

    Activates 2nd fuel dump of 1 min.

    NO FLAME (After 7min 50 sec mark) Activates 3rd fuel dump of 1 min.

    NO FLAME (After 14 min 15 sec mark) Activates Fault LED / enters Fault Mode

    If Flame Detection is established near the end of Start-up Mode, the 14 min. 15 sec. time line is extended to complete sequence. After 1 min from Flame Detection, Fuel Feed goes to

    20% for 4 min 15 sec before entering panel setting. After 2 min from Flame Detection, Convection Fan

    enters panel setting and Igniter turns OFF. After 5 min 15 sec from Flame Detection, Combustion

    Fan enters panel setting.

    Traditions Models Model Profile 20 Profile 30 Models

    NOTE: Absence of light causes high Ohms!

    7 K Ohms (7,000) or higher shuts off the Photo Eye

    5 minutes of 7 K or higher = Fault Shutdown during Demand Mode

    This area should be checked during routine maintenance and cleaned with a small brush to ensure slot is free of fines or dust.

  • Revision D 8/10/20001

    14

    Combustion Air Supply

    PN 12050011

    FASCO # 7201-10232 Type U12B Class B 115 Volts 60 HZ 2800 RPM 1.0 Amps Thermally Protected No oiling required

    Pictured with Quick Disconnect

    The Profile 20 & 30 series, along with the Traditions models, house a thermally protected Class B insulated combustion fan motor. It connects to the wiring harness via a two pin white Molex plug connection. The wire leads are 18 ga. as well as the as the green motor ground wire.

    A 12 blade self-cleaning radial impeller draws air from upstream (the firebox) creating negative firebox pressure. Down stream, out the exhaust, the flue system is pressurized by the displaced air (exhaust). Typical performance of free air is rated at 95 CFM at 66 watts. The Ohms range is 9-14 (+/- 4 Ohms).

    Motor lubrication not required.

    The Cascade model houses a FASCO blower assembly, which is made up of one 115 VAC, 60 Hz, 2.10 AMP, and 1400-200 RPM, Class B thermally protected motor. For combustion, the fan operates at 1680 RPM on low with 90CFM free air and at 2300 RPM on high with 109 CFM. The combustion fan housing, attached by 5 nuts, contains an 11-blade self-cleaning radial fan blade. When removal is required, the blower assembly access is from the rear of appliance. Disconnect the Molex plug; remove the 5 nuts on the combustion fan housing, and the 4 nutsmounting the convection fan housing.

    The blower assembly is then

    dropped out the bottom of the appliance. Some panel removal may be required for ease of access. No motor lubrication is required for this assembly.

    PN: 17140110 (FASCO # 7021-9301)

  • Revision D 8/10/20001

    15

    Convection Air Supply

    PN 12146109

    FASCO # 7021-7786 Class B Motor 115 Volts 60 HZ 1.6 Amp 80 CFM Variable Speed Thermally Protected

    The squirrel cage collects house hold dust deposits, dust bunnies, and care should be given to perform routine maintenance in this area. As the room air passes through the convection jacket and the heat exchanger, it cools the firebox by displacing the heated air into the room. Restricted air ways will cause harmonic noise, uneven air flow and could lead to high temperature shutdown conditions detected by High Limit switch. Motor lubrication is not required for this sealed fan motor.

    The Profile 20 & 30 series, and the Traditions model, house a thermally protected Class B insulated convection fan motor. It connects to the wiring harness via a two pin white Molex plug connection. The wire leads are 18 Ga. as well as the as the green motor ground wire.

    A plastic squirrel cage, attached to the motor shaft by a compression ring, draws room air into the fan housing in the rear of the appliance chassis.

    Any exhaust leak will be drawn toward this fan intake.

    The Cascade convection fan, part of the blower kit assembly, has a plastic squirrel cage impeller. It draws ambient air from the room into the convection jacket through the heat exchanger. This cools the firebox and provides convection heat to the room. Exhaust leaks from the flue system can be drawn into this fan. Smells and/or ash within the room are reason for flue seal inspection.

  • Revision D 8/10/20001

    16

    Safety Systems

    CONTROL BOARD

    CONVECTION BLOWER

    HI-LIMIT SWITCH

    PHOTO-EYE AUGER MOTOR

    PRESSURE SWITCH

    POWER CORD PLUG

    THERMOSTAT CONNECTION

    COMBUSTION BLOWER

    IGNITER PROBE

    Rear view of Profile 30 wiring and components

    AIR INLET TUBE

  • Revision D 8/10/20001

    17

    Safety Systems

    CASCADE MODEL

    Symptoms

    Pressure Switch: Negative Vacuum Switch Tri-Delta FR 5251 Yellow Label Normally Open switch Switch closes at + 0.04 WC (+/- .02)

    Symptoms: No pellet feed Backpressure in flue causes vacuum loss The Vacuum switch is located on the left hand side-facing appliance. The switch is wired in series with the Auger motor and High Limit switch. Failure of this switch is rare. If power is restored to the feed system by electrically bypassing this switch, maintenance is required to flue system. Two wires plug into switch. Electrically by-pass the switch by disconnecting wires and jumping them together

    Low Limit Snap Switch: Bak-OLite / Therm-O-Disc 60T22 Normally Open switch at room temperature Switch closes on exhaust temp. rise (above 140 F) Resets on exhaust temp. drop (below 130 F)

    Symptoms: No power after 25 min from start Switch failed to Close Stove will not shut off when cold (no fire) Switch failed Open The Low Limit switch is mounted on the exhaust Tran duct. Yellow and Red wires from wiring harness connect to the two terminals on switch body. During normal operation all power runs through switch. Pushing the Slide switch to Low or High initiates a 25 min timer within control panel. Within this cycle, exhaust temperature should rise above 140 F with a fire in firebox closing the switch. If temperature falls below 130 F power is lost as switch opens.

    High Limit Snap Switch: Bak-O-Lite / Threm-O-Disk 36T21 Normally Closed switch at room temperature Switch opens on surface temp. rise (above 190 F) Resets on surface temp. drop (below 170 F)

    Symptoms: No fuel feed system power Switch test OPEN Overtemp condition The High Limit switch is located on the rear of the convection jacket, left hand side-facing appliance. Two brown wires from harness connect to terminal leads of switch. The switch is wired in series with the Auger motor and Vacuum switch. Failure of this switch causes loss of auger motor circuit power. Bypassing the switch, by disconnecting and jumping wires together, will determine if switch has thermally opened. PN 12150162

    PN 12150080

    PN 17150075

  • Revision D 8/10/20001

    18

    Safety Systems

    PROFILE 20 / 30 & TRADITIONS MODEL

    Photo Eye (C554A) Ceramic disk coated with Cadmium Sulfide &

    overlaid with a conductive grid. (High resistance in absence of light)

    The entire cell is glass to metal sealed to prevent cell deterioration.

    The wire leads are UL tested for up to 105 C at 300V & connect to control board jumper leads

    Ohms range 100 to 10,000 Electrodes attached to the ceramic disk transmit

    an electrical signal to the primary controller at 7,000 Ohms

    High Limit Snap Switches Normally Closed Open at 250 F and reset at 220 F Found at two locations, Inlet air channel & on

    Convection jacket

    PN 12147705

    PN 19050196 The mount bracket is different between each model. The location will always be to the control board side of the stove on the backside of the firebox / convection jacket.

    Pressure Switch (Purple Label) Located on the Combustion side of stove

    connected to exhaust cowling of Combustion fan by an orange hose.

    Normally closed switch that opens when +. 17 wc back pressure is sensed by the inner diaphragm PN 12147705

    Door Micro Switch (Profile 30 ONLY) Located on the latch side of door, lower

    right corner behind side panel.

    Activated by secured closed door. Wired in the auger motor circuit. Open switch prevent fuel feed.

    PN 12150080

  • Revision D 8/10/20001

    19

    Question & Answers

    WHAT ARE THE REASONS FOR FAULT DETECTED SHUTDOWN? If the start sequence ends without a flame being detected If Flame Detect is lost for 45 seconds continuous during start up/ Flame Detect mode If the flame is lost during the demand mode for 5 minutes continuous

    RESULTS No Flame Detected = Power LED flashes 10 flashes per second Same as the Normal Shutdown previously described EXCEPT

    3941 Control Board will shut off at 24 minutes 15 seconds after Start-up sequence with no flame detected.

    WHAT INITATES A NORMAL SHUTDOWN? Power is switched off Thermostat indicates no need for heat

    RESULTS Combustion Fan goes to mid range voltage for 15 minutes than turns OFF Convection Fan goes to mid range voltage to cool down

    One minute after shut down sequence is initiated 15 minutes after shutdown sequence is initiated

    All circuits will be turned OFF

    Combustion Fan Operation extends to 5 minutes 15 seconds past Flame Detect before allowing panel setting to take control. Convection Fan Operation extends to 2 minutes past Flame Detect before allowing panel setting to take control. At 2 minutes past Flame Detect Fuel Feed drops to 20% rate for 4 minutes 15 seconds before allowing panel setting to take control. NOTE: The first minute after Flame Detect, NO

    If a Flame is detected near the end of the Start-up Sequence, the 14 minutes 15 seconds sequence is extended to allow flame settling and ember bed to build.

    WHAT ELECTRICALY TAKES PLACE AFTER A DELAYED IGNITION START-UP?

  • Revision D 8/10/20001

    20

    Question & Answers

    DEMAND Mode State: If the thermostat is closed when power is restored there is a need for the unit to

    produce heat. If flame is present the unit will enter the Demand Mode and run the loads at

    panel settings. If the flame is not present the unit will initiate the Start-up Sequence.

    If the thermostat is open when the power is restored there is no need for the unit to produce heat.

    The unit will enter the shutdown sequence to prevent the possibility of any smoldering pellets from producing smoke that will possibly escape the firebox into the living space.

    If the control board is in shutdown when power is lost the control board will initiate the shutdown sequence when power to the control board is restored.

    SHUT DOWN Mode State

    START-UP Mode State

    If the thermostat does indicate a need for heat when power is restored to the control board and if a flame is detected the control board will enter the demand mode of operation. If a flame is not detected the control board will initiate the start-up mode of operation. If the thermostat does not indicate a need for heat when power is restored to the control board the shutdown sequence will be initiated.

    Recovery from power loss situation is dependent on the state the stove was in when power was lost.

    WHAT HAPPENS AFTER A POWER OUTAGE?

  • Revision D 8/10/20001

    21

    Troubleshooting Chart

  • Revision D 8/10/20001

    22

    Maintenance Requirements

    Ash Slides: Profile 20 and 30 freestanding models have ash slides that close with the closing of the appliances door. The Profile 30 insert contains NO ASH SLIDES. The Cascade and Traditions ash slides require the operator to ensure closure. If during appliance burn operation, an ash slide is open or loose seal, combustion air is lost and poor performance can be expected. Test the tightness of seal by placing a finger on the closed slide and press down. If there is any sponginess, the ash slide guides need to be tightened. Access to the guides is through the ash drawer compartment. Tighten the lock nuts on the guide studs (4 each)

    Ash Drawers: Each model has an ash drawer. The Profile 30 insert is inside the firebox under the grate. Both the Profile 20 and 30 freestanding models have high capacity ash drawers. These models can withstand long burn usage before needing the ash drawer to be emptied. The Cascade and Tradition models, as well as the Profile 30 insert, need attention to ash build up in the ash drawer below the grate. Heavy ash accumulation here will reduce combustion air availability to the grate. Care must be given when empting ash drawers. Hot embers may be present and ash will escape into the room if exposed to air currents from the convection blower while handling the drawer.

    Ash Trap Areas: Ash trap area is defined as any location ash will collect in volume and cause air flow or heat transfer problems. In the Profile 30 there are two access panels, one on either side of the grate that should be checked during routine maintenance. (Shown in the top picture to the left.) Heat exchange tubes have cleaning rods that should be operated, pulled up and down, daily. When ash is allowed to collect on the tubes, it insulates the tubes and reduces heat transfer. (Traditions tubes shown to left, handle inside firebox) Heavy ash build-up around the tubes will restrict the cleaning rods movement and could affect proper closure of the hopper lid.

  • Revision D 8/10/20001

    23

    Maintenance Requirements

    Gaskets: Door gasket seals are common leak areas. A paper seal test should be performed periodically to ensure proper door seal. Remember any excessive leak in the combustion chamber, firebox, takes away from the proper air to fuel ratio. Gaskets are held in place with RTV. When replacing a gasket, use the proper replacement size and clean area of old RTV to ensure a good seat on the new gasket. Gaskets should last, with proper care, two to three seasons.

    Ash Removal: Ash is the residue of pellet combustion. The term soot is often misused to describe ash. This dust collects in the exhaust air flow chambers of the appliance. If left unattended, it restricts air flow. In the firebox, ash builds to the sides of the grate. By opening the ash slides, the majority of it will drop into the ash drawer. REMEMBER to close the slides fully when stove is operating in the all models. Excessive ash build-up in the firebox will affect the air wash performance. Always ensure there are no hot embers when dumping ash drawer. Never use a paper bag to deposit ash into.

    Flue vent systems should be cleaned at least once a burn season. This may become more frequent depending on fuel and appliance use. All vent pipeswithin the home shall be sealed air tight to prevent ash leakage. The flue vent system on all LENNOX Hearth Products is under positive pressure when the appliance is operating. Leaks in the flue vent system contribute to ash being found throughout the home but the main cause for this is the use of a regular shop vacuum. The filter system of such equipment is not able to handle the collection and containment of pellet ash. Photo-eye Slot: Fines may build up in front of the photo-eye slot in the feed tube. Clean this area with a small bottle brush or toothbrush periodically. The failure of fuel feed during operational modes could be the result of a blinded photo-eye.

  • Revision D 8/10/20001

    24

    Replacement Parts List

    Common to all Models

    Part # old Common to T300's, Pro 20 & 30, WP5 PN new 11756300 Auger Shaft C 12041300 Auger Collar & Set Screw, 3pc. C 12046300 Auger Motor C 12050093 Quick Disconnect 3" Vent Side C 12051263 Ultra Grate C 12055500 Grate Scraper Tool C 12058820 Power Cord C

    Quick Disconnect Pipe Connector 4" C 14M81 15051547 Gasket, Door, 3/4" Rope, 8ft. C 61050003 Gasket, Auger End Plate, 5pc. C 61050005 Gasket, Combustion Fan, 5pc. C 61057203 Gasket, Convection Fan, 5pc. C

    Touch-up Spray Paint Kit, Black C 70K99

    Common to Profile / Traditions Models

    12050011 Combustion Blower C 12051001 Auger Bumper C

    Wiring Harness C 11M54 12140213 Igniter Probe C 12146109 Convection, Hard washer, Blower C 12147705 Hi Limit Snap switch, 250 DG (L250-30F, 60T21) C 16050001 Pressure Switch C 16050205 Thermostat C

    Replacement Parts Planning: When forecasting what parts to carry in stock, use the simple rule of Classification. That is to determine what parts are required for the appliance to operate, function properly and/or maintain there appeal. Classification 1:

    Any part, which not installed, prevents the appliance from running. Classification 2:

    Any part, not properly functioning, causes poor performance. Classification 3:

    Any part that adds to the appearance of the appliance.

    Base the amount of parts to stock now on the percentage of appliances in stock and in service. Remember some parts are common to many models.

  • Revision D 8/10/20001

    25

    Replacement Parts Lists

    Cascade Specific

    Cascade 14M42 12150080 Low Limit Snap switch WP5 12150162 High Limit Snap switch WP5 12151412 Knob, Ash Pan WP5 13740005 Lock Arm, Lid Support WP5 17140110 Blower Assembly Kit WP5 17150025 Firebrick Panel WP5 17150027 Control Board WP5 17150028 Knob, Control Board WP5 17150029 Damper Rod WP5 17150030 Leg Set, Black, Painted WP5 17150046 Ash Lip, Black, Painted WP5 17150075 Pressure Switch WP5 17150084 Glass, Door WP5 17150086 Door Handle WP5 17150126 Wiring Harness WP5 17150147 Louver, Assembly, Black Painted WP5 17150150 Panel, Top, Black, Painted WP5 17150163 Panel, LHS, Black, Painted WP5 17150164 Panel, RHS, Black, Painted WP5 17150243 Ultra Grate WP5 17151132 Leg Set, Black, Powder Coated WP5 17151146 Ash Lip, Black, Powder Coated WP5 17151147 Louver, Assembly, Black, Powder Coated WP5 17151150 Panel, Top, Black, Powder Coated WP5 17151153 Panel, LHS, Black, Powder Coated WP5 17151154 Panel, RHS, Black, Powder Coated WP5

    Door Assembly, Gold WP5 14M44 17152018 Ash Pan, Black WP5

    Louver, Assembly, Gold WP5 14M45 17157100 Gasket, Door Assembly, Kit WP5 40020076 Video, Operation & maintenance WP5

    CASCADE

    Brochures: PN 775.016M Purchases qualify for co-op reimbursement

    PN new

  • Revision D 8/10/20001

    26

    Replacement Parts Lists

    Profile 20 Specific

    Profile 20 (Freestanding) 14M43 12050020 Glass, Front, 1pc. P20 12050021 Glass, Side, 1pc. P20 13640028 Brick Clips P20 14650003 Side Panel, LHS P20 14650004 Side Panel, RHS P20 14650006 Firebox Door Assembly P20 14650011 Firebrick Set P20 14650012 Top Panel P20 14650043 Photo eye Assembly P20 14650047 Hinge Bracket, Door P20 14650048 Rear Panel P20 16053941 Control Board P20 17250095 Door Handle P20 17250241 Auger End Plate P20 61050016 Gasket, Quick Disconnect, 5pc. P20 61057202 Gasket, Glass, 10ft. P20

    Trim Set, Gold P20 14M46 Trim Set, Nickel P20 14M47

    PROFILE 20 Freestanding

    Brochures: PN 775.017M (All Profile Freestanding and Insert models)

    Purchases qualify for co-op reimbursement

    PN new

  • Revision D 8/10/20001

    27

    Replacement Parts Lists

    Profile 30 series Specific

    Part # Profile 30 (Common-C) 11750011 Brick Clips - C P30 12050004 Brush, Cleaning - C P30 12146402 Glass, Door - C P30 14750015 Firebrick Set -C P30 14750021 Hinge Bracket, Door - C P30 14750111 Firebox Door Assembly - C P30 14750127 Photo Eye Assembly - C P30 16052112 Control Board - C P30 17150095 Door Handle - C P30 17250241 Auger End Plate - C P30 61050016 Gasket, Quick Disconnect, 5 pc. - C P30 61057208 Gasket, Glass, 4 ft. - C P30

    Profile 30 (Freestanding-FS) 14M48 14750060 Top Panel - FS P30 14750070 Side Panel, LHS - FS P30 14750075 Side Panel, RHS - FS P30 14750150 Rear Panel - FS P30 14750186 Pedestal Assembly P30

    Profile 30 (Insert-IN) 14M51 14750300 Top Panel - IN P30 14750340 Side Panel, LHS - IN P30 14750345 Side Panel, RHS - IN P30

    Shroud, Small - IN P30 14M52 Shroud, Medium - IN P30 14M53 Shroud, Large - IN P30 14M54 Trim, Small Shroud, Brass - IN P30 14M55 Trim, Medium Shroud, Brass - IN P30 14M56 Trim, Large Shroud, Brass - IN P30 14M57

    PN new

    Trim Set, Gold Trim Set, Nickel

    14M4914M50

  • Revision D 8/10/20001

    28

    Replacement Parts Lists

    Traditions Specific

    Traditions (FS) Metallic Black T300P 14M82 Traditions (FS) Ebony Black T301P 14M83 Traditions (FS) Hunter Green T305P 14M84 Traditions (FS) Mojave Sand T308P 14M85

    26021 Paint, Touch-up, Green Enamel T 26022 Paint, Touch-up, Black Enamel T 26023 Paint, Touch-up, Sand Enamel T

    Trivet, Gold Plated T 14M16 16055150 Control Board T 17150029 Damper Rod Assembly Kit T 20751075 Leveler Legs, 2pc T 20950005 Door Handle Assembly Kit T 20950014 Heat Exchange Baffle T 20950087 Auger End Plate T 20950091 Ash pan Assembly T 20950100 Rear Panel Assembly T 20950150 Firebrick Set T 20950153 Log Set T 20950155 Brick Clips, 2ea T 20950196 Photo eye Mount T 20950205 Hopper Lid Assembly Kit T 20953002 Cast Door Frame, Black Painted T 20953003 Cast Top, Black Painted T 20953006 Trivet, Black T 20953012 Cast Door Frame, Black Enamel T 20953013 Cast Top, Black Enamel T 20953052 Cast Door Frame, Green Enamel T 20953053 Cast Top, Green Enamel T 20953082 Cast Door Frame, Sand Enamel T 20953083 Cast Top, Sand Enamel T 20959999 Glass, Door T 29050110 Gasket, Quick Disconnect T 61057208 Gasket, Glass, 4ft. T

    Traditions

    Brochures: PN 775.016M

    Purchases qualify for co-op reimbursement

    PN new

  • Revision D 8/10/20001

    29

    Technical Bulletins / Updates

    Model NO. Date Serial Number Range Topic PN CASCADE C-1 8/8/95 Start at 1015 Changed Hi-limit switch 18150162 C-2 8/8/95 Start at 1591 Feed Rate OFF time 17150027 PROFILE 20 Bulletin 01 6/11/00 All Pressure Switch Kit 16050001 Bulletin P1270 9/27/00 1000 2020 Photo Eye Position 19050196 Bulletin PJ030 10/3/00 1000 1712 Door Gasket Change 15051547 Advisory PJ110 10/11/00 All Installation Manual 20922000 Bulletin T2000-01 11/28/00 1896 2406 Photo Eye Slot Location 19050196 Addendum 3/16/01 3814 UP Wiring Diagram (pg 5) 20922000 Addendum 4/26/01 3814 UP Wiring Diagram (pg 5) 20922000 Addendum 7/17/01 All Installation/Operation Man 20922000 PROFILE 30 Bulletin 01 6/11/00 All Pressure Switch Kit 16050001 Bulletin PJ030 10/3/00 1000 1712 Door Gasket Change 15051547 Bulletin T2000-01 11/28/00 1896 2406 Photo Eye Slot Location 19050196 Bulletin T2000-02 12/13/00 1001 4074 Wiring Harness 11M54 Addendum 4/26/01 3814 UP Wiring Diagram (pg 5) 20922000 Addendum 7/17/01 All Installation/Operation Man 20922000 TRADITIONS Bulletin 01 6/11/00 All Pressure Switch Kit 16050001 Bulletin T2000-01 11/28/00 1896 2406 Photo Eye Slot Location 19050196 Addendum 4/26/01 3814 UP Wiring Diagram (pg 5) 20922000 Addendum 7/17/01 All Installation/Operation Man 20922000

    Governing Codes & Approvals

    Local authorities have final jurisdiction.

    Certified for CANADA and US Listed for manufactured homes in accordance with Oregon Administrative

    Rules 814-23-900 through 814-23-909 Listed Room Heaters for use with APFI/FFI approved palletized wood fuel ONLY Use 3 or 4 Type L listed pellet vent and complete components Tested to:

    o ASTM 1509 o UL 1482 o ULC-S627 o ULC-S628

    WHPN 025 Reports: Cascade Report # Profile 20 Report # 6658 (Jul 93) Profile 30 Report # 476-1244 (Mar 96) Traditions Report # 476-1129 (Apr 95)