PE Penetrants

5
Zyglo ® ZL-2C Post Emulsifiable Fluorescent Penetrant ZL-2C’s formulation has been designed to be impervious to water to protect it from over washing and permit more penetrant to remain in discontinuities for improved detection of small defects. It and other post emulsifiable penetrants require the application of a lipophilic or hydrophilic emulsifier to render them washable with water. Zyglo ® ZL-2C fluoresces a bright greenish-yellow under ultraviolet radiation. Use of an ultraviolet light source with a peak wavelength of 365 nanometers, such as the MAGNAFLUX ® ZB-100F fan- cooled black light, is recommended. Zyglo ® ZL-2C penetrant meets OSHA requirements for Class III B liquids due to its high flash point and can be used in open dip tanks. MATERIAL SAFETY DATA SHEET PRODUCT DATA SHEET DISTRIBUTOR LIST APPLICATION INSTRUCTIONS LPI EQUIPMENT BLACK LIGHTS Specificatio ns Compliance: AMS-2644, AECL, ASME B & PV Code Sec V, ASTM E1417, MIL- STD-2132, ASTM E165, MIL-STD-271 Part Number and Container Size: 01-3123-40: 5 Gallon Pail 01-3123-30: 20 Gallon Drum 01-3123-45: 55 Gallon Drum Applications : Zyglo ® ZL- 2C is typically used on castings, forgings, extrusions and rough and machined surfaces to find cracks, seams, laps, laminations and porosity. Classificati on: Type 1, Method B Penetrant when using ZE-4B emulsifier. Type 1, Method D Penetrant when using ZR-10B (20%) remover. Penetrant Sensitivity Level: Level

description

PE Penetrants

Transcript of PE Penetrants

ZygloZL-2C Post Emulsifiable Fluorescent PenetrantZL-2Cs formulation has been designed to be impervious to water to protect it from over washing and permit more penetrant to remain in discontinuities for improved detection of small defects. It and other post emulsifiable penetrants require the application of a lipophilic or hydrophilic emulsifier to render them washable with water.ZygloZL-2C fluoresces a bright greenish-yellow under ultraviolet radiation. Use of an ultraviolet light source with a peak wavelength of 365 nanometers, such as the MAGNAFLUXZB-100F fan-cooled black light, is recommended.ZygloZL-2C penetrant meets OSHA requirements for Class III B liquids due to its high flash point and can be used in open dip tanks. MATERIAL SAFETY DATA SHEET PRODUCT DATA SHEET DISTRIBUTOR LIST APPLICATION INSTRUCTIONS LPI EQUIPMENT BLACK LIGHTSSpecifications Compliance:AMS-2644, AECL, ASME B & PV Code Sec V, ASTM E1417, MIL-STD-2132, ASTM E165, MIL-STD-271Part Number and Container Size: 01-3123-40: 5 Gallon Pail 01-3123-30: 20 Gallon Drum 01-3123-45: 55 Gallon DrumApplications:ZygloZL-2C is typically used on castings, forgings, extrusions and rough and machined surfaces to find cracks, seams, laps, laminations and porosity.Classification:Type 1, Method B Penetrant when using ZE-4B emulsifier. Type 1, Method D Penetrant when using ZR-10B (20%) remover.Penetrant Sensitivity Level:Level 2 - Normal Sensitivity

ZygloZL-27A Post Emulsifiable Fluorescent PenetrantZL-27As formulation has been designed to be impervious to water to protect it from over washing and permit more penetrant to remain in discontinuities for improved detection of small defects. It and other post emulsifiable penetrants require the application of a lipophilic or hydrophilic emulsifier to render them washable with water.ZygloZL-27A fluoresces a bright greenish-yellow under ultraviolet radiation. Use of an ultraviolet light source with a peak wavelength of 365 nanometers, such as the MAGNAFLUXZB-100F fan-cooled black light, is recommended.ZygloZL-27A penetrant meets OSHA requirements for Class III B liquids due to its high flash point and can be used in open dip tanks. MATERIAL SAFETY DATA SHEET PRODUCT DATA SHEET DISTRIBUTOR LIST APPLICATION INSTRUCTIONS LPI EQUIPMENT BLACK LIGHTSSpecifications Compliance:AMS-2644, ASTM E 1417, MIL-STD-271, ASME B & PV Code, Sec. V, MIL-STD-2132, Boeing BAC 5423 PSD 6-46 or 8-4, AECL, ASTM E 165, Boeing PS-21202Part Number and Container Size: 01-3187-40:5 Gallon Pail 01-3187-30:20 GallonDrum 01-3187-45:55 GallonDrumAlso Available in 16oz. Aerosol Cans.Applications:ZygloZL-27A is typically used on castings, forgings, extrusions and rough and machined surfaces to find cracks, seams, laps, laminations and porosity.Classification:Type 1, Method B Penetrant when using ZE-4B emulsifier. Type 1, Method D Penetrant when using ZR-10B (20%) remover.Sensitivity Level:Level 3 - High Sensitivity

ZygloZL-37 Post Emulsifiable Fluorescent PenetrantZL-37s formulation has been designed to be impervious to water to protect it from over washing and permit more penetrant to remain in discontinuities for improved detection of small defects. It and other post emulsifiable penetrants require the application of a lipophilic or hydrophilic emulsifier to render them washable with water.ZygloZL-37 fluoresces a bright greenish-yellow under ultraviolet radiation. Use of an ultraviolet light source with a peak wavelength of 365 nanometers, such as the MAGNAFLUXZB-100F fan-cooled black light, is recommended.ZygloZL-37 penetrant meets OSHA requirements for Class III B liquids due to its high flash point and can be used in open dip tanks. MATERIAL SAFETY DATA SHEET PRODUCT DATA SHEET DISTRIBUTOR LIST APPLICATION INSTRUCTIONS LPI EQUIPMENT BLACK LIGHTSSpecifications Compliance:AMS-2644,ASTM E 1417,MIL-STD-271, ASME B & PV Code, Sec. V, MIL-STD-2132, Boeing BAC 5423 PSD 6-46 or 8-4, AECL, ASTM E 165, Boeing PS-21202Part Number and Container Size: 01-3188-40: 5 Gallon Pail 01-3188-30:20 Gallon Drum 01-3188-45: 55 Gallon DrumApplications:ZygloZL-37 is ideal for titanium turbine components, investment castings and other high stress critical components where detection of fine, tight discontinuities is required.Classification:Type 1, Method B Penetrant when using ZE-4B emulsifier.Type 1, Method D Penetrant when using ZR-10B (20%) remover.Sensitivity Level:Level 4 - Ultra-High Sensitivity