PaNel PC CEMS/Opacity/Flow/FTIR · 2018-01-02 · dURaG Opacity Systems lAutomatic zero and span...

2
CEMS/Opacity/Flow/FTIR CHEROKEE NORTH CAROLINA: 100 Logan Court | Angier, NC 27501 TENNESSEE: 8703 Unicorn Drive, Suite 302 | Knoxville, TN 37923 800.399.4236 www.ampcherokee.com NOx SO2 CO CO2 O2 THC HCl NH3 H2S TRS CONTINUOUS EMISSIONS MONITORING SYSTEMS FOR EMISSIONS COMPLIANCE AND PROCESS MEASUREMENT PERMANENT | TEMPORARY | PROCESS MONITORING www.ampcherokee.com MiniCEMS® is a registered trademark of AMP-Cherokee Microsoft SQL Server® is a registered trademark of Microsoft Corporation Allen-Bradley® is a registered trademark of Rockwell Automation ©2018 AMP-Cherokee Environmental Solutions | All Rights Reserved DIRECT EXTRACTIVE CEMS FLOW SCHEMATIC VACUUM PUMP VACUUM PUMP VACUUM PUMP COALESCING FILTER W/ WATER SLIP SENSOR SAMPLE PUMP PERISTALTIC PUMP CALIBRATION GASES REAL-TIME PRESSURE SENSORS SO2 ANALYZER CO/CO2 ANALYZER NOx/O2 ANALYZER EXCESS FLOW FLOW SWITCH ROTAMETER SAMPLE PROBE GAS CONDITIONER W/ PELTIER CHILLER SAMPLE PRECOOLER BLOWBACK HEATED SAMPLE LINE FLOW SWITCH SAMPLE MANIFOLD HEATED FILTER 1-LITER BLOWBACK RESERVOIR STACK GAS FLOW CONDENSATE DRAIN SENSOR INPUTS POLLING PC PANEL PC OPC SERVER OPC SERVER STATUS SERVER STATUS SERVER SQL EXPRESS SQL SERVER PLC SYSTEM CONTROLLER DATA REDUNDANCY W/ AUTO DATA RESTORE REPORTING MODULE ALARMS / NOTIFICATIONS SQL DATA SYCHRONIZATION HMI DISPLAY

Transcript of PaNel PC CEMS/Opacity/Flow/FTIR · 2018-01-02 · dURaG Opacity Systems lAutomatic zero and span...

Page 1: PaNel PC CEMS/Opacity/Flow/FTIR · 2018-01-02 · dURaG Opacity Systems lAutomatic zero and span check lAutomatic measurement and correction of contamination of optical surfaces lExtremely

CEMS/Opacity/Flow/FTIR

CHEROKEE

NORTH CAROLINA: 100 Logan Court | Angier, NC 27501TENNESSEE: 8703 Unicorn Drive, Suite 302 | Knoxville, TN 37923800.399.4236 www.ampcherokee.com

NOx

SO2

CO

CO2

O2

THC

HCl

NH3

H2S

TRS

CONTINUOUS EMISSIONS MONITORING SYSTEMS

fOR EMISSIONS COMplIaNCE aNd pROCESS MEaSUREMENT

pERMaNENT | TEMpORaRY | pROCESS MONITORING

www.ampcherokee.com

MiniCEMS® is a registered trademark of AMP-CherokeeMicrosoft SQL Server® is a registered trademark of Microsoft Corporation

Allen-Bradley® is a registered trademark of Rockwell Automation©2018 AMP-Cherokee Environmental Solutions | All Rights Reserved

HMI DISPLAY

diReCT exTRaCTive CemS flOw SCHemaTiC

VACUUMPUMP

VACUUMPUMP

VACUUMPUMP

COALESCINGFILTER W/

WATER SLIP SENSOR

SAMPLEPUMP

PERISTALTICPUMP

CALIBRATION GASES

REAL-TIME PRESSURE

SENSORS

SO2 ANALYZER

CO/CO2 ANALYZER

NOx/O2 ANALYZER

EXCESS FLOW

FLOWSWITCH

ROTAMETER

SAMPLEPROBE

GASCONDITIONER

W/ PELTIERCHILLER

SAMPLEPRECOOLER

BLOWBACK

HEATED SAMPLE LINE

FLOW SWITCH

SAMPLE MANIFOLD

HEATED FILTER

1-LITERBLOWBACKRESERVOIR

STACK

GASFLOW

CONDENSATEDRAIN

SENSOR INPUTS

POlliNG PC

PaNel PC

OPC SERVER

OPC SERVER

STATUS SERVER

STATUS SERVER

SQL EXPRESS

SQL SERVER

PLC SYSTEM CONTROLLER

DATA REDUNDANCY W/AUTO DATA RESTORE

REPORTING MODULE

ALARMS / NOTIFICATIONS

SQL DATASYCHRONIZATION

HMI DISPLAY

Page 2: PaNel PC CEMS/Opacity/Flow/FTIR · 2018-01-02 · dURaG Opacity Systems lAutomatic zero and span check lAutomatic measurement and correction of contamination of optical surfaces lExtremely

CEMS/Opacity/Flow/FTIRContinuous Emissions & Performance Monitoring Systems

integrated CemS/PemS/daS SolutionsFrom application-specific monitoring system design and integration to installation and commissioning, AMP-Cherokee provides direct-extractive and dilution-extractive CEM systems, and predictive emissions monitoring systems (PEMS), with our integrated DAS. Built for maximum reliability and minimal maintenance, AMP-Cherokee can accurately quantify exotic compounds through in-situ or extractive FTIR systems.

AMP-Cherokee CEM systems can be configured to monitor for one or all of the following:

• NOx • SO2 • CO2 • O2 • CO • THC • TRS • Mercury

• H2S • HCl / HF Acid • NH3 • Particulate • Opacity

• Volumetric Flow / Moisture • Custom CEM Applications

accurate. Redundant. Reliable.AMP-Cherokee is the only CEMS integrator to offer redundant sampling system components as standard equipment. Redundant features include integral Teflon lines for sample, calibration and blowback, backup sample pump/gas conditioner, as well as the necessary connections for up to ten gas components (5 dual detector analyzers).

AMP-Cherokee CEM systems are built to your specifications and optimized for accurate measurements and reliable performance to keep the cost of your system operation to a minimum.

ease of Operation & maintenanceCEM systems from AMP-Cherokee are the easiest to operate and maintain. The HMI interface and plug-anwd-play design sets a new standard in reliability and ease of operation. With built-in redundant sampling, system uptime is protected.

KURZ Series 220 isokinetic flowSampling SystemsKurz offers a complete isokinetic sampling system to ensure true sample composition — from stack flow monitoring and sample capture to sample flow control.

dURaG Opacity Systemsl Automatic zero and span checkl Automatic measurement and correction of contamination of optical surfacesl Extremely powerful and stable super-wide band diode (SWBD) light sourcel Extremely low-maintenancel Fail-safe shutter purge air optionl Certified according to EN 15267-3l Compliant with 40 CFR 60 PS1 & ASTM 6216

mKS fTiR-based CemS Simultaneously monitors multiple compounds on a real-time basis at ppm or ppb concentration levels.

intrinsically Safe & explosion-Proof Sheltersl Stock & Custom Sizesl Climate Controlsl Bulkheads & Other Access Pointsl Electric Service (120 VAC to 480 3-Phase)l Aluminum or Steel Constructionl Site Installation & Commissioningl Calibration Gas Bottle Station (Exterior)

ShElTER CEMS

Direct Extractive CEMS

dilUTiON exTRaCTive CemS flOw SCHemaTiC

Dilution Extractive CEMS

Hmi SQl SeRveR

SAMPLEPUMP

FLOWSWITCH

DILUTION PROBE

EXHAUSTS

STACK

GASFLOW

CALIBRATION GASESW/ REAL-TIME

PRESSURE SENSORS

VACUUMPUMP

VACUUMPUMP

VACUUMPUMP

SO2 ANALYZER

CO/CO2 ANALYZER

NOx/O2 ANALYZER

EXCESS SAMPLE GAS

GAS SAMPLE MANIFOLD

DILUTION AIR PANEL

DILUTION FLOW CONTROLLER

FLOWSWITCH

DILUTED GAS SAMPLE

DILUTION AIR

POlliNG PC

PaNel PC

OPC SERVER

OPC SERVER

STATUS SERVER

STATUS SERVER

HMI DISPLAY

HMI DISPLAY

SQL EXPRESS

SQL SERVER

PLC SYSTEM CONTROLLER

DATA REDUNDANCY W/AUTO DATA RESTORE

REPORTING MODULE

ALARMS / NOTIFICATIONS

SQL DATASYCHRONIZATION

HMI/Panel PC