Panel controls seattlemsslc2011

41
ADAPTIVE LIGHTING CONTROLS PANEL: Susan Zamos, FP Controls, Sun-Tech Rod Stummer, Owlet, Schreder Group

Transcript of Panel controls seattlemsslc2011

Page 1: Panel controls seattlemsslc2011

ADAPTIVE LIGHTING CONTROLS PANEL:

Susan Zamos, FP Controls, Sun-TechRod Stummer, Owlet, Schreder Group

Page 2: Panel controls seattlemsslc2011

TOPICS•Communication standards•Commissioning•Control System Features•Reporting/User Interface

Page 3: Panel controls seattlemsslc2011

Open Communication

Standards

Page 4: Panel controls seattlemsslc2011

The 7 OSI Layers

The Open Systems Interconnection (OSI) Model was developed by International Organization for Standardization (ISO) in the 1980s as an attempt to make communication between any two systems possible.

Before this, every equipment manufacturer implemented its own set of rules (protocols). Therefore, two computers made by different companies could not "understand" each other.

7

6

5

4

3

2

1

Page 5: Panel controls seattlemsslc2011

OtherApplications

OtherMedia Technologies ZigBee® Technology

LonWorks™ TechnologyEIA & De facto Standard

US DOT NTCIP 1213 Electrical Lighting &

Management SystemsStandard

To Assure Interoperability,- All 7 OSI Layers Must Be Supported

7

6

5

4

3

2

1

7

6

5

4

3

2

1

Page 6: Panel controls seattlemsslc2011

Why ZigBee?• Open Global Standard• Supports Mesh Networks• Low Duty Cycle• Low Latency/Power• Low Cost• Up to 65,000 Nodes Per Network• 128-bit AES Encryption• Interoperability Between Products• Robust and Reliable• Self-healing, Re-routing Network

Page 7: Panel controls seattlemsslc2011

Why ZigBee?• Industrial Grade Wireless• 16 Communication Channels

• Each with Max. Bandwidth• Auto or Manual Selection• Dynamic Frequency

Hopping• Noise Detection

• 250 kbit/second• 50X Faster than Powerline• Open Intl. Standard IEEE

802.15.4

Page 8: Panel controls seattlemsslc2011

Zigbee Applications• Demand Response • Advanced Metering Infrastructure • Automatic Meter Reading • Lighting controls • HVAC control • Heating control • Wireless smoke and CO detectors • Home security • Blind, drapery and shade controls • Medical sensing and monitoring • Remote control of home entertainment systems • Indoor location sensing • Advertising on mobile devices

Page 9: Panel controls seattlemsslc2011

ZigB

eevs

Oth

er W

irele

ssZigBee 802.11

(Wi-Fi)Bluetooth UWB (Ultra Wide Band) Wireless USB IR Wireless

Data Rate 20, 40, and 250 Kbits/s 11 & 54 Mbits/sec 1 Mbits/s 100-500 Mbits/s 62.5 Kbits/s 20-40 Kbits/s115 Kbits/s

4 & 16 Mbits/s

Range 10-100 meters 50-100 meters 10 meters <10 meters 10 meters <10 meters (line of sight)

Networking Topology Ad-hoc, peer to peer, star, or mesh

Point to hub Ad-hoc, very small networks

Point to point Point to point Point to point

Operating Frequency 868 MHz (Europe)900-928 MHz (NA), 2.4

GHz (worldwide)

2.4 and 5 GHz 2.4 GHz 3.1-10.6 GHz 2.4 GHz 800-900 nm

Complexity (Device and application impact)

Low High High Medium Low Low

Power Consumption (Battery option and life)

Very low (low power is a design goal)

High Medium Low Low Low

Security 128 AES plus application layer

security

64 and 128 bit encyption

Other Information Devices can join an existing network in

under 30ms

Device connection requires 3-5 seconds

Device connection requires up to 10

seconds

Typical Applications Industrial control and monitoring, sensor networks, building automation, home

control and automation, toys,

games

Wireless LAN connectivity, broadband

Internet access

Wireless connectivity between devices such

as phones, PDA, laptops, headsets

Streaming video, home entertainment

applications

PC peripheral connections

Remote controls, PC, PDA, phone, laptop

links

Page 10: Panel controls seattlemsslc2011

Where Does ZigBee Fit?

Page 11: Panel controls seattlemsslc2011

ZigBee – A Growing Standard!

“Low power wireless sensing and control markets, enabled by ZigBee, are experiencing exponential growth. Today, ZigBee chipset suppliers are shipping tens of millions of

units and the market is poised to grow to hundreds of millions of units within the next few years. Our research with more than 600 companies has found that the ZigBeemarket has "crossed the chasm" and is now a mainstream technology. Despite a

challenging economy, 802.15.4/ZigBee unit sales have increased an average of 62% per year since 2007. Moreover, chipsets using ZigBee specifications made up 75% of

the 802.15.4 shipped units in 2009.”

ON WORLD Research Group (Published May ‘10)

Page 12: Panel controls seattlemsslc2011

Commissioning a System• Commissioning Plan

– RF Mapping Plan for Network Planning• Important to plan the optimum number and positions for the Base

Stations (Gateways) to achieve proper radio coverage. Radio planning tools should be used that make use of geographic terrain and clutter data and radio propagation models.

• The radio model / map is then used in conjunction with a site survey with local authorities and contractor staff to confirm Base Station sites and document installation details.

Page 13: Panel controls seattlemsslc2011

Typical Radio Mapping

Page 14: Panel controls seattlemsslc2011

• Asset list and information• Commissioning Training – Before starting

installations! • Dimming profiles for each type fixture (response to

0-10 v dimming signal is not typically linear)• Operational Training – make sure user’s

expectations are realistic• The better the planning, the better the system.

Commissioning

Page 15: Panel controls seattlemsslc2011

The endpoints (nodes)of a mesh network mustbe installed starting close to the coordinatorin order to maintain the mesh.

Page 16: Panel controls seattlemsslc2011

The endpoints of a star network can be installed randomly throughout the coverage area.

Page 17: Panel controls seattlemsslc2011

Adaptive Lighting Controls Panel

CONTACT INFORMATION:

Susan ZamosSales Director

Sunrise Technologies - FP Outdoor Lighting Controls54 Commercial St., Raynham, MA 02767

[email protected]

Page 18: Panel controls seattlemsslc2011

Control System Features• Monitoring / Maintenance

• Reduce Night Inspections• Diagnose Faults• Reduce Repair Times

• Trimming (Constant Lumen Output)• Eliminates Over-Lighting

• Selective Dynamic Dimming• Save Energy in Off-Peak Periods

• Metering• Insures Energy Savings From Utilities

Page 19: Panel controls seattlemsslc2011

Monitoring

• Diagnose• Lamp Failures and Cycling• Driver/Ballast Failures• Power Failures• Energy Usage Changes• Lamp Life and Driver Warranty History

Page 20: Panel controls seattlemsslc2011

Trimming(Constant Lumen Output)

• Reduces Wattage in Early Life Stages and Maintains Optimum Lumen Output

• As the Light Engine / Lamp Ages, Wattage is Gradually Increased to Maintain Optimum Lumen Output

Page 21: Panel controls seattlemsslc2011

Dimming

• 0-10 VDC• Simple and Reliable• Requires Dimming Driver/Ballast• Most common in U.S.

• DALI• Developed for Indoor• Offers 2-Way Communication• Widely Used in Europe (HID)

Page 22: Panel controls seattlemsslc2011

Metering

• Dimming streetlights can save up to 30% in energy

• Utilities need a reliable metering method to credit cities for this energy savings

Page 23: Panel controls seattlemsslc2011
Page 24: Panel controls seattlemsslc2011

Metering• Utilities are requiring a minimum ± 2% accuracy

• On-board power meter chipset• Not an algorithmic estimation

• Must measure accurately in a• Steady-state• Dim modes

• Leading the Standards• CPUC (Calif. Public Utility Comm.)• PG&E Utility

• San Jose, San Francisco• MSSL (Controls Task Force Spec.)• NEMA, NIST-SGIP, ANSI

Page 25: Panel controls seattlemsslc2011

User InterfacesField Level

RF Communication Interface (IEEE 802.15.4, ZigBee Protocol)Enables the luminaire controller to control the LED driver

Gateway LevelCommunication interface to the management serverManages and stores information from the field controllers

Server LevelScalable database (Microsoft, Oracle, SAP)Webserver applicationProvides a graphical user interface (GUI) reachable with a standard webbrowser (Internet Explorer, Firefox, Chrome, Safari, etc.)

Page 26: Panel controls seattlemsslc2011

Build the wireless communication and management system

Supports:• Continuous live data between

gateway router and luminaire controllers

• Data is stored at the gateway router level and uploaded to the server database on demand or on a pre-defined schedule

• Field initiated communication requests is established between the gateway controller and server through configuring IT services (SNMP) to send alarm notifications (text message, email, etc.)

User Interfaces

Page 27: Panel controls seattlemsslc2011

Web Interface• Standard user/role permission configuration• Permissions set for user/groups•Monitoring• Reporting• Configuration•Administration

• Special rights for manual commands and expert views

Graphical User Interface

Page 28: Panel controls seattlemsslc2011

Used during commissioning to locate luminaire controllers and gateway routers on mapping software

Mapping Interface

Page 29: Panel controls seattlemsslc2011

Used to visually monitor operation of field level luminaire controllers and gateway routers

Mapping Interface

Page 30: Panel controls seattlemsslc2011

• Malfunctions (Error Reporting)Broken lamp/ballast, energy-limits, power factor, lost nodes, communication loss

Reporting System

Page 31: Panel controls seattlemsslc2011

Example of Error Reporting Screen

Page 32: Panel controls seattlemsslc2011

• Malfunctions (Error Reporting)Broken lamp/ballast, energy-limits, power factor, lost nodes, communication loss

• Monitoring (Live View)Individuals/Groups, Dim-Levels, Control-Signals, Run Hours, Switch On/Off Times, Errors, Energy Consumption, Electrical Power Usage, Voltage, Current, Power Factor, Controller Failure, Device Uptime, Temperature, Communication Quality, Timestamp, Calculated Sun Elevation, Device Information

Reporting System

Page 33: Panel controls seattlemsslc2011

Example of Monitoring Screen

Page 34: Panel controls seattlemsslc2011

• Reporting (Energy and Detail Report)• Energy Consumption on City, District, Area and Streetlight Level• Table and Chart Views• Streetlight Level: Energy Consumption, Run Hours, Burning Hours

Dimming Profile, On/Off Times, Error List• Reports Viewable On-Line and Exportable to CSV and PDF

Reporting System

Page 35: Panel controls seattlemsslc2011

Example of Screen Reports

Energy Report

Error Report

Page 36: Panel controls seattlemsslc2011

Example of Admin Screen

Page 37: Panel controls seattlemsslc2011

Example of Admin Screen

Page 38: Panel controls seattlemsslc2011

Example of Configuration Screen

Page 39: Panel controls seattlemsslc2011

SmartPhone, iPAD, Remote Interface

Page 40: Panel controls seattlemsslc2011

Controls Panel

CONTACT INFORMATION:Rod Stummer

Director of Business DevelopmentSchreder Lighting – OWLET Controls

2105 W. Corporate Drive, Addison, IL 60101Office: 847-621-5100 Cell: 847-345-2414

[email protected]