1. System Design Map
Water Tank
Fertilizer Tank A
Fertilizer Tank B
Fertilizer Tank C
Filter
Automatic Pump
Tube Well
Valve 2”Feed Pump 1HP
Filter 2” Mix Tank
Hydronic Valve
Controller
Water Pump 2HP
Valve 2”
Ventury/Flow meter
ManometerFilter 2”
Filter
Valve 3/4” Solenoid Valve1~12 Area
Design
Water TankTube Well : Maintain a plenty of waterAutomatic Pump : Install Auto-controlling water levelFilter : Filter substance of water
Mix TankHydronic Valve : Maintain continuity/stability of water Mixing Tank : Mix fertilizer from a VenturyTank Volume : 200 L
ControllerIrrigate by fix timeControl fixed EC/pH valueCPU : Micom( Auto-controlled distributing board)
※Option : Add a function of Ph
SEO WON CO., LTD http://www.seowonco.com/eng
Page 3
2HP Pump
EC Sensor
Hydronic Valve
Manometer
2. SW-1004E SYSTEM
1.System Detail
SW-1004E (EC Controlled Fertilizing System)
Irrigated Ability (MAX)
22,000 L / H
Supply Fertilizer 30 ~ 300 L / H (Optional:PH)
Control Control by ratio of fixed value
Volume Width 107Cm × Length 92Cm × Height 110Cm
Weight 110Kg
Power SupplyThree phases four-wire system AC380V/60Hz / Single phase AC220V2.Contents
LCD
Mix Tank : 200 L
Switches
Electric board
Aluminum frame
Ventury
Solenoid
Flow meter
In/Out board
Keyboard(20keys)
Adjust Height Lock
SEO WON CO., LTD http://www.seowonco.com/eng
Page 4
3. SW-1004 CHARACTRISTICS
System Characteristics
Contents Remarks
Control • Time Control : Irrigate by hour/minute (MAX: 24 times)
• Interval Control : Irrigate by hour/minute (MAX: 99 times)
• Light Control : Irrigate by light (Optional)
Irrigation • Time Irrigation : Cover areas individually by fixed time (M:S)
Solenoid Valve
• Control total 12 areas ※ Add areas (Optional)
Program • EC / PH : Set up EC/PH value by areas
• Fertilizer ON/OFF : Set by time
•Report : Data for the day & 15 days irrigation
• Alarm : EC over value(+1)/PH under value(-1) alarm and stop function
• Test : Feed pump, water pump, and solenoid valve test function
• Simple : Simple one time watering (One Touch Function)
• Pause : Emergency stop (One Touch Function)
• Trouble shooting : print instruction when error occurs
Hardware • LCD( width 40 X length 4 )• Hydronic Valve : Maintain continuity/stability of water (From Water Tank)
• Pressure Valve : Control stable pressure of water
• Exclusive valve & fitting with chemical resistance
• 40mm Aluminum Firm Body
• Non-corrosion control panel
SEO WON CO., LTD http://www.seowonco.com/eng
Page 5
4. controller
Instructions
Large LCD Screen with backlight installed.
Numeral punching key – punch in for set up values in each mode.# : delete for target no.←/↑/→/↓: use for moving the cursor at each mode
Menu : shows all set up menus and use at any screen.
Emergency Irrigation: pressure this button once at discretion when not in irrigation set up time.
Pause : press this button for operation stop and re button for restart.
Enter : press this button after punching in set up values completely.
Material : Aluminum - no rusty and solid.
Power Switch Board
Waterworks : waterworks motor run.- Manual- Pause-Automatic
Mixing: Irrigation motor run- Manual - Pause- Automatic
- Power Switch-
On & Off
Preliminary switch for PH option.
Fertilizer A: fertilizer solenoid valve-Manual: supply fertilizer manually-Stop: stop supplying fertilizer-Automatic: supply fertilizer automatically
Fertilizer B: fertilizer solenoid valve-Manual: supply fertilizer manually-Stop: stop supplying fertilizer-Automatic: supply fertilizer automatically
㈜ 서 원 양 행 http://www.seowonco.com
Page 6
5. Start & Menu Screen
Current Date / Time
Start Screen
Number of Irrigation done
today
Time control/ Interval control
Current EC value
Irrigation time cycles
Scheduled irrigation interval
Current pH value (optional)
Menu Screen
⊙ General screen display when the power is ON.
⊙ Press “Menu” button to switch the screen.
⊙ Press numbers in a keyboard to enter the menu.
Time/ Date/ Cycles setting mode
Irrigation Time setting mode
Irrigation amount per
block and EC value per block setting mode
Manual irrigation (one
time) in an emergency
Pump/ Fertilizer solenoid vale & electric valve testing mode
Irrigation report for the past
15days
※ ※ The numbers showing on the start screen shall determine from input numbers The numbers showing on the start screen shall determine from input numbers on on
Time and Interval control.Time and Interval control.
SEO WON Co.,Ltd. http://www.seowonco.com
Page 7
6. Time/ Date/ Irrigation Cycles/ Control Method & Irrigation Time Setting Mode
Current date setting
Time/ Date/ Irrigation Cycles/ Control Method Setting Mode
Irrigation cycles setting
(Interval from 1~ 9 days)
Control setting1. Time setting
(standard)2. Time interval
setting (standard)
Current Time setting
Control instructions
Irrigation starts when remaining irrigation days becomes “ 0 (zero) ”.
Irrigation Time setting(Time control )- standard
⊙ Press “Menu” button → Press Number “1” → Setting Time/ Date/ Irrigation cycles, Controlling.⊙ Cursor movement : press “ ← / →” button⊙ Press “ Enter” to save program.
Irrigation sequence (24times
possible daily)
Irrigation Time: Hour setting
Irrigation Time: minute setting
“1” indicates irrigation with fertilizer. “0”
indicates without fertilizer
⊙ Press “Menu” button → Press Number “2” → set irrigation time⊙ Cursor movement: : Press “← / → /↑ / ↓” button (press “ ↓” to move next page )⊙ Irrigation cycles : 1 ~ 24 times setting ⊙ Set irrigation time which not using to be “0 (hour)” & “ 0 (minutes)” .⊙ Fertilizer dosing: Set number “1” when setting irrigation time. “0” without fertilizer. ⊙ Press “Enter” to save program
Press “↓ or →” to see 9th irrigation sequence
㈜ 서 원 양 행 http://www.seowonco.com
Set “0” & “0” for irrigation time
which not using.
Page 8
7. Irrigation Time setting ( Interval control)
Irrigation Start time
Irrigation End time:
Set end time regardless of
remaining irrigation cycles.
Irrigation interval:Set time from start to next sequence
time
Fertilizer dosing: “1” indicates
irrigation with fertilizer. “0”
indicates without fertilizer
⊙ Press “Menu” button → press number “2” → irrigation interval setting⊙ Cursor movement : press “← /→” button⊙ Irrigation cycles: up to 99 times possible⊙ Fertilizer dosing: Set number “1” when setting irrigation time. “0” without fertilizer. ⊙ Press “Enter” button to save program
Remaining cycles:Cycles that left
from already set no. of cycles.
Irrigation cycles setting (1~99 times)
Irrigation Time setting (Interval control)- Standard
㈜ 서 원 양 행 http://www.seowonco.com
Page 9
8. Irrigation amount per block / EC amount / Emergency Irrigation setting mode
Irrigation block
Irrigation amount per block / EC value setting
Irrigation amount setting
“M”
Irrigation amount setting
“S”
Set pH value on crops per block
Set “0 (zero)” for blocks not using.
Emergency Irrigation mode
⊙ Press “Menu” button: press number “3” → move to irrigation setting mode screen⊙ Cursor movement : press “→/←/↓/↑” button⊙ Possible for multi crops by setting EC / Ph amount⊙ Press “Enter” to save program
Set EC value on crops per block
⊙ Press “Menu” button: press number “4” → start ⊙ Ready to use irrigation once ( same function as indicated “ Emergency Irrigation” in the keyboard)⊙ Press “Enter” to exit the program
㈜ 서 원 양 행 http://www.seowonco.com
Page 10
9. Output test and irrigation report view
Water supply pump test
Output test
Irrigation pump test
Section electric valve test
Fert. (B) valve test
Fert .(A) valve test
Irrigation report
⊙ screen movement : press “MENU” key →press number “5” → output test⊙ check whether Pump 1/Pump 2/Dosing solenoid valve/Electric valves per section operate or not⊙ cursor movement: “ ↑ / ↓ / ← / → “ ⊙ exit: “ENTER/MENU
Previous day view
Irrigation report “Month”
Irrigation report “Date”
Total irrigation amount
(minute) for the day
Fert. (C) valve test
⊙ screen movement : press “MENU → press number of “6” → irrigation report view⊙ cursor movement : “← / → “ ⊙ saving date : irrigation amount (time) & irrigated times for last 15 days⊙ exit : “ENTER”
Total irrigated times for the
day
Section
Current radius view
Current EC view
Current pH view
Radius sum:total radius
amount for the day
SEO WON CO., LTD http://www.seowonco.com
Page 11
10. Output Status and Error Report Screen
irrigation pump running check
Output Status
current EC value indication
setting time per section
irrigating section
remaining irrigation time
Fertilizer Warning & Running Stop
•⊙ Appears automatically during irrigation•⊙ Able to change Setting Values of part mode during irrigation.•⊙ Return to initial screen after irrigation.
fertilizer valve running check
•⊙ Sounds an alarm if the EC value is over “I” and pass 30seconds during irrigation.•⊙ When it passes 30seconds after alarm, system running stops with below screen.•⊙ Follow up the screen’s instructions and press “HALT”, Then, start again to operate.•⊙ Continue to operation : “HALT” key
Water supply running check
current PH value indication
⊙ Can stop the operation by pressing “HALT” button.⊙ If you want to operate again, press “HALT” button.
HALT in operation
SEO WON CO., LTD http://www.seowonco.com
Page 12
11. System Maintenance
1. Daily
⊙ Check the system irrigates normally or not
⊙ irrigation volume check
⊙ EC / PH measurement of soil and culture ground
2. Weekly
⊙ Cleaning all filters
⊙ Fertilizer volume check of fertilizer tank
⊙ Ventury check and cleaning
⊙ EC / PH sensor cleaning
3. Monthly
⊙ Drip tape check and cleaning
⊙ Check whether all valves operate normally
⊙ Normal operation check of other equipment and facility
4. After cultivation
⊙ Culture ground and soil sterilization
⊙ Culture ground cleaning by water
⊙ Fertilizer supply piping cleaning
SEO WON CO., LTD http://www.seowonco.com
Page 13
EC Converter ZERO (standard value) adjustment method
ZERO Adjustment of EC Converter
1. Prepare EC standard solution. (if there is no standard solution, prepare EC portable whose close to standard value)2. Prepare “-” driver. (a kind of clock driver)3. Remove EC sensor from SW-1004E system.4. Put EC sensor into the standard solution or the solution which is checked with EC portable.5. Open cabinet in front of system and find the EC converter.6. Turn on system power and check the ‘Current EC” value of the initial screen.7. Adjust by turn right or left “SPAN” volume in the center of the EC converter by using driver.8. Set to the EC value which is checked with standard solution or EC portable.9. Adjust exactly by repeating more than 3 times.※ Never adjust other volumes of EC converter.※ Put the EC sensor into the solution as deep as possible.
ZERO adjustment drive
Never adjust!!ZEROSPAN
ZERO adjustment volume“SPAN”
about 10 round adjustment to
left/right
Never adjust!!ZERO 4mASPAN 20mA
EC sensor connecting parts(from left side)
1, 2, 3, 4, T1,T2, G
EC Sensor Management Tip
1. Check and adjust ZERO by using standard solution once a month.
2. Clean the sensor surface by smooth cloth once a week.
SEO WON CO., LTD http://www.seowonco.com