Page 1: User´s Manual - galconc.com · fertilizer control valve, ... ¾ Before attempting any maintenance work on the injectors, close all manual valves at the fertilizer tank outlet

Fertijet

Galcon Kfar Blum Tel. 972-4-6900222 Fax. 972-4-6902727Email. [email protected] Website. www.galconc.com

User´s Manual

Page 2: User´s Manual - galconc.com · fertilizer control valve, ... ¾ Before attempting any maintenance work on the injectors, close all manual valves at the fertilizer tank outlet

1

Fertijet Manual

Page 1

Fertijet – enhanced fertigation machine

User manual

1. General Description Fertijet is a compact, simple and modular fertigation control system for use in both greenhouses and open field irrigation applications. Fertijet is designed for accurate injection of nutrients into the irrigation water pipe through a set of Venturi type fertilizer injectors under EC & pH control and optional irrigation control by the advanced Elgal computerized controller. Fertijet can be fitted quickly and easily on almost any irrigation head. 1.1 System Components A standard Fertijet unit consists of the following components: • A set of 3 Venturi type fertilizer injectors with a flow rate

of up to 90 GPH each. Each injector contains an electric fertilizer control valve, an adjustable flow regulator, and a flexible suction pipe.

• A water pump (1.5, 2.5 or 3 H.P.) with a stainless steel head, to obtain a flow of water through the fertilizer injectors and insert the solution into the water pipeline.

• An EC & pH monitor unit, consisting of a transmitter with a 4-20 mA output, galvanic insulation, a large LCD display and a four-button keyboard for soft calibration.

• A pair of EC & pH electrodes, installed in a sampling cell. • An Elgal irrigation/ fertigation controller. • An electrical control panel, also including connection terminal blocks. • An inlet and an outlet for irrigation water.

1.2 Safety Instructions Before installing and connecting the Fertijet in place, read the “Pre- Installation” manual carefully and follow all the instructions applicable to Fertijet. To install the Fertijet and associated equipment, follow NFPA 70 directives strictly. Have high voltage (> 60V) electrical connections made only by a local, qualified electrician. Do not operate the Fertijet before ensuring full connection to a valid grounding point (1Ω or lower). Before removing the electrical box cover, shut the main power switch Off. Before attempting any maintenance work on the booster pump, shut the main power switch Off.

Page 3: User´s Manual - galconc.com · fertilizer control valve, ... ¾ Before attempting any maintenance work on the injectors, close all manual valves at the fertilizer tank outlet

2

Fertimix User´s Manual Fertijet Manual

Page 2

Since Fertijet is designed to inject dissolved chemicals, some of which are dangerous in contact or inhalation, use protecting glasses, rubber gloves and gas mask as required. Before attempting any maintenance work on the injectors, close all manual valves at the fertilizer tank outlet Follow all local regulation as applicable to storage and handling of chemicals. Before attempting to remove or install the water piping system, depressurize all main pipes.

2. Installation and Connection 2.1 Plumbing

Applications Four types of applications are available:

a. Typical: Mainline not pressurized while the Fertijet is off. Mainline pressure ≤ 70 PSI.

b. Non- driven: Mainline optionally pressurized while the Fertijet is off. Mainline pressure ≤ 70 PSI.

c. High pressure: Mainline not pressurized while the Fertijet is off. Mainline pressure ≥ 70 PSI.

d. HP Non- driven: Mainline optionally pressurized while the Fertijet is off. Mainline pressure ≥ 70 PSI.

control Read

Figure 1: Typical Installation

Figure 2: Non-Driven

control

Read

Page 4: User´s Manual - galconc.com · fertilizer control valve, ... ¾ Before attempting any maintenance work on the injectors, close all manual valves at the fertilizer tank outlet

3

Fertimix User´s ManualFertijet Manual

Page 3

Procedure (1) Unpack the Fertijet and rest it on a solid base. Mount the I/O box on a solid wall or post. (2) Connect the 32mm inlet and outlet pipes to the mainline as shown above. (3) Connect the blue pipe (water sampling for EC and pH sensor measurements) to the main

irrigation line at a point at least 1.5m (4 feet) downstream from Fertijet’s outlet connection. Note that the exact recommended distance depends on the water flow speed in the main pipe. For more accurate calculation, use your Internet browser to refer to the URL: ftp://ftp.eldarshany.com/pub/literature/fert_calc.xls

(4) Open the EC-pH sampling cup and remove the pH sensor cover. Fill the sampling cup with water and mount it back in place. Important: The pH sensor must be immersed in water at all times.

Fertilizer Suction

Water Inlet

Water & Fertilizer Outlet

1 2

3 Sampling Water Suction

Figure 5: Fertijet Plumbing

control Read

Figure 3: High Pressure

control

Read

Figure 4: HP Non-Driven

Page 5: User´s Manual - galconc.com · fertilizer control valve, ... ¾ Before attempting any maintenance work on the injectors, close all manual valves at the fertilizer tank outlet

4

Fertimix User´s ManualFertijet Manual

Page 4

(5) Connect the pipes from the fertilizer tanks to the fertilizer injector inlets: Fertijet default

settings define Injectors #1 and #2 as nutrients injectors (EC injectors allowing correction of quantities according to conductivity) and Injector #3 as an acid injector (pH injector attempting to maintain pH stability). For a different configuration (e.g. two acid injectors and one fertilizer),change the settings in menu screen no. 5216.

2.2 Wiring Power Supply Connections (1) Booster pump power connection:

Have a local, qualified electrician connect the booster pump load according to the marking sticker at the end of the HD (green) cable.

(2) Controller and communication connection: Plug the controller and communication (white) cable to the local mains using a connection box (not a wall socket!). Verify that this power point is protected by a 6A circuit breaker.

fuse

3.1

5

com

A B C D

A B C D

comm.out

OPT

out

puts

out

out 1

out 2

out 3

out 4

gnd

fuse

3.1

5

com

A B C D

A B C D

comm.out

OPT

out

puts

out

out 5

out 6

out 7

out 8

gnd

fuse

3.1

5

com

A B C D

A B C D

comm.out

OPT

out

puts

out

out 9

out 1

0ou

t 11

out 1

2

gnd

com

A B C D

A B C D

comm.inp

IPT

inpu

ts

out

in 1

in 2

in 3

in 4

gnd

mai

n va

lvefe

rt. (w

ater

)pum

p

mai

n pu

mp

alar

m

fert.

pum

p A

wat

er c

ount

.

low

pre

ss.

fert.

pum

p B

fert.

pum

p C

Elgal outputsconnector

com

A B C D

A B C D

comm.inp

IPT

inpu

ts

out

in 5

in 6

in 7

in 8

gnd

Elgal inputs conn.fe

rt. c

ount

. A

fert.

cou

nt. B

fert.

cou

nt. C

fert.

cou

nt. D

fert.

cou

nt. E

fert.

cou

nt. F

fert.

pum

p D

fert.

pum

p E

fert.

pum

p F

Output Connections (1) Verify that all field valves as well as the main valve, main pump, filters flushing and any

other such elements are all 24V AC operated, with a maximum rating of 5W. (2) Open the I/O box cover and identify the OPTN cards. Notice the numbers marked on the

cards: these are output numbers left free for your own use after applying the Fertijet’s accessories (injectors valves, booster pump). Connect your deices to the free points and record your connections on ID Book page 4. Attention: The default settings allocate Output 1 for the main valve and output 2 for the main pump. To change these settings, e.g. for the sake of standardization, see ID Book page 4 (right column).

Figure 6: Input/Output Connections

Page 6: User´s Manual - galconc.com · fertilizer control valve, ... ¾ Before attempting any maintenance work on the injectors, close all manual valves at the fertilizer tank outlet

5

Fertimix User´s ManualFertijet Manual

Page 5

(3) Set the controller as required to acknowledge your connections. To set, follow instructions as applicable to the program used (see table below):

Fetijet with 1CL_IR Software (Elgal 12/24) Fertijet with Open Field Software (Elgal

2000/Midi) Follow the instructions in the “Elgal Setup” manual, Chapter 2, to define and allocate your outputs according to your previous ID Book listings.

Follow the instructions in the “Elgal Agro” operation manual, page D25 (code 751,) to define and allocate your outputs according to your previous ID Book listings.

Should you need any help navigating in the Elgal menu – read “Basics” (Chapter 1) in the Elgal manual.

(4) Check menu 4 (Alarms) for a possible double- output alarm. The controller will invoke such alarm in the event of inadvertent use of the same output for two different devices.

Discrete Inputs Connections (1) Verify that the water meter, rain pulse sensor, motor fault switch and any other such

elements are all of a dry- contact type. The controller will supply 12-24V DC to one of the contact polls and will track a change in contact status.

(2) Identify the IPT terminal cards in the I/O box. Notice the numbers marked on the cards: these are the input numbers left free for your own use after applying the Fertijet’s accessories (booster pump overload trip, low pressure switch ). Connect your own devices to the free points and record your connections on ID Book page 6. Attention: The default settings allocate Input 1 for the water meter pulse. To change these settings, e.g. for the sake of standardization, see ID Book page 6 (right column).

(3) Set the controller as required to acknowledge your connections. Should you need any help navigating in the Elgal menu – read “Basics” (Chapter 1) in the Elgal manual. To set, follow instructions as applicable to the program used (see table below):

Fetijet with 1CL_IR Software (Elgal 12/24) Fertijet with Open Field Software (Elgal

2000/Midi) Follow the instructions in the “Elgal Setup” manual, Chapter 2, to define and allocate your inputs according to your previous ID Book listings.

Follow the instructions in the “Elgal Agro” operation manual, page D25 (code 752,) to define and allocate your inputs according to your previous ID Book listings.

Page 7: User´s Manual - galconc.com · fertilizer control valve, ... ¾ Before attempting any maintenance work on the injectors, close all manual valves at the fertilizer tank outlet

6

Fertimix User´s ManualFertijet Manual

Page 6

Cut-Off Pressure Set Differential Set

Differential Scale

Differential Indicator Cut-Off Scale Cut-Off Indicator

2.3 Low Pressure Switch The Fertijet features a low pressure (LP) switch to prevent pump operation under a low water pressure. The LP switch is initially adjusted to 35 PSI. To change, follow the instructions below. WARNING! Reducing the value below 25 PSI will endanger your booster pump and void our warrantee immediately! To change LP switch settings, remove the black cover to expose two screws at the top of the unit. Use only that screw which is closest to the back line. To reduce the pressure, turn the screw clockwise (you will see a metal line move up on the scale). To increase the pressure, turn the screw counterclockwise.

2.4 EC-pH Sampling Cell Pressure The pH probe provided is a low pressure probe. Never expose it to a pressure higher than 50 PSI. To adjust cell pressure, first verify that the main line is pressurized and the Fertijet’s booster pump is running. To adjust, follow this procedure: (1) Close the manual valve at the blue sampling pipe inlet. (2) Remove one of the probes from the cell’s top. (3) Open the manual valve gradually until the water slightly overflows

from the empty hole. (4) Re-fit the probe in place and fasten its gland. (5) Recommendation: Remove manual valve’s handle to prevent

inadvertent readjustment.

3. Irrigation System Setup Each system is uniquely characterized by own water meter pulse, valve flow rates, fertilizer types and settings. All of these parameters are necessary for system operation and must be programmed on the site before the first operation. To set system parameters, follow instructions as applicable to the program used (see table below):

Fetijet with 1CL_IR Software (Elgal 12/24) Fertijet with Open Field Software (Elgal

2000/Midi) Follow the instructions on “Irrigation software” manual page I2-1 and top of page I2-2. Fertijet may be used either as a “standard” system when applied to the entire irrigation system or as “Fert-Only” system when applied to the fertigation system alone.

Follow the instructions on “Elgal Agro” manual pages D20 (code 45) and D23 (code 72).

On completion, both the controller and the irrigation system are ready for operation.

Kg/cm2 Bar PSI 1 0.98 14.22 2 1.96 28.44 3 2.94 42.67 4 3.92 56.89 5 4.90 71.11 6 5.88 85.34

Figure 7: LP Switch

Page 8: User´s Manual - galconc.com · fertilizer control valve, ... ¾ Before attempting any maintenance work on the injectors, close all manual valves at the fertilizer tank outlet

7

Fertimix User´s ManualFertijet Manual

Page 7

4. Operation 4.1 Using the Irrigation Program

To operate the system, follow instructions as applicable to the program used (see table below):

Fetijet with 1CL_IR Software (Elgal 12/24) Fertijet with Open Field Software (Elgal 2000/Galileo)

Follow “Irrigation Software” manual instructions on the daily use of the irrigation program.

Follow “Elgal-Agro” manual instructions on the daily use of the irrigation program.

4.2 Fertilizer Injectors Adjustment

Every fertilizer injector must be flow- adjusted to some extent. To adjust, use one of three methods as listed below: a. Fixed cone-jets of 20, 40, 60 and 80 liter/hour (5, 10, 15 and 20 GPM). b. Flow- control valve. c. Flow indicator with control valve. Follow the instructions in the table below as applicable to the method selected for each injector:

Step Cone-jet Adjustable valve Flow indicator 1 Establish optimal pump flow to inject during 40-70% of the irrigation time, taking into

consideration the specific mainline flow, fertilizer concentration and final quantity of nutrient required. Consult ftp://ftp.eldarshany.com/pub/literature/Fert_Calc.xls (“Fert Calc” sheet) as required.

2 Fit jet in housing

Remove bottom cover of fertilizer solenoid valve by unscrewing the 2 flat bolts.

3 Immerse the far end of the flexible pipe in a measurable bucket of water. Start the irrigation program.

Immerse the far end of the flexible pipe in a bucket of water. Start the irrigation program.

Page 9: User´s Manual - galconc.com · fertilizer control valve, ... ¾ Before attempting any maintenance work on the injectors, close all manual valves at the fertilizer tank outlet

8

Fertimix User´s ManualFertijet Manual

Page 8

4 Press the solenoid’s plunger up with your finger for exactly 30 seconds.

Press the solenoid’s plunger up with your finger and set the required flow on the scale.

5 Measure the amount of water pumped out of the bucket. Calculate the flow by multiplying the quantity of the missing water by 120.

Fit the plunger protector back in place and secure with bolts.

6 Adjust the valve slightly. Repeat steps 4-5 until the required flow is obtained. Fit the plunger protector back in place and secure with bolts.

7 Update the “Fertilizer pump flow” parameter in the controller: code <5216 #3> in CL_IR 2.04 or code <452 #3>

4.3 Fertigation Automation Adjustment This chapter is intended to clarify some special features of Fertijet, which are not explained in the Elgal manual. Please read the complete irrigation chapter in the Elgal manual to better understand the fertigation method of the Elgal controller. Description Fertijet does not pre-set the point where the EC-pH sample is taken. This decision is left to the technician who installs the machine. This point and the length of the pipe to the sampling cell both have a considerable effect on the fertilizer automation function. When the program changes the water-to-fertilizer ratio, a timer is set to define the minimum time to the next change (if required). This function serves to identify the impact of the last change as soon as possible, then make the next change. Performing the second change before reading the results of the first one would cause overshooting, and the EC and pH may never become balanced. On the other hand, a slow reaction is not desirable either. Calculating the shortest response time is not an easy task. If you have Internet access, you can find an on-line calculator for that purpose at: ftp://ftp.eldarshany.com/pub/literature/Fert_Calc.xls (“Fertijet balancer” sheet). All you have to do is type your application details in the appropriate cells, and the calculator will come on with the results. If you do not have access to the Internet, use this formula: Rt = ht + dt + Dt + 3 where: SQ – the flow of the smallest shift in the irrigation system D – the internal diameter of the main pipe Dl – the distance between the fertilizer insertion point and the sampling outlet in the main pipe (cm) Dt – the delay time in the main pipe; Dt = (((D / 2)2 * π) * Dl) / SQ dl – the length of the 32mm pipe from the Fertijet outlet to the main pipe (m) dt – the time in the 32mm pipe (sec); dt = dl / 13.9 hl – the length of blue sampling hose (m); ht = hl / 0.4

Page 10: User´s Manual - galconc.com · fertilizer control valve, ... ¾ Before attempting any maintenance work on the injectors, close all manual valves at the fertilizer tank outlet

9

Fertimix User´s ManualFertijet Manual

Page 9

ht – the time in blue sampling hose (sec) Rt – the response time required

Notes

Calculation as above may be problematic since different units are used in different countries. The last 3 seconds added to the calculation represent probe’s response time. “dl” is subject to many changes as may be caused by line pressure, pump model (MXH 405 or 805), number and type of Venturi pumps, and even fertilizer valves position (on or off). However, as you will find when you do the calculation, as long as you do not install the Fertijet at a distance greater than one or two meters from the insertion point, the effect on the calculation would be negligible.

Procedure (1) Calculate shortest response time (Rt) as above. (2) Save calculation result under the respective parameter in the controller. To save, press

<5241> and <R> on the controller panel or (for PC users) click <settings>, <Irrigation>, <Fertigation setup>. The text displayed on the panel will be “Change fert. Delay – sec.”, with a default value 8. Enter calculation result, then press <Enter>.

(3) Move to the next parameter. The text displayed will be “Delay at start – sec.”, with a recommended value two and a half times the change delay. Press <Exit>.

(4) You will now be prompted to save the last changes. Press <Enter> to confirm the default setting, or, if you use a PC, click the key icon and change the desired parameters. A second click on the key icon will send your changes to the controller after confirmation.

Fertijet

EC -pH

Dl

hl dl

Figure 8: Rt Calculation

Page 11: User´s Manual - galconc.com · fertilizer control valve, ... ¾ Before attempting any maintenance work on the injectors, close all manual valves at the fertilizer tank outlet

10

Fertijet Manual

Page 10

5. Maintenance 5.1 Fertijet Maintenance Board

Component

Action

One month after first operation

Weekly

Monthly

End of Season

Electrical connections

Shut off main power switch and fasten all screws securely.

X

Fertilizer tank filters

Clean.

X

Booster pump

Run with fresh water for 5 minutes, then bleed all water out.

X

Fertilizer solenoids (Sirai)

Wash crystallized minerals. Lubricate plunger with silicon oil.

X

Fertilizer Venturi injectors

Adjust flow, clean possibly clogged jets.

X

EC-pH 3050 Calibrate probes. X X – to be performed by a local, authorized electrician. 5.2 Winterizing

Winter time in frost- ridden areas may prove quite harmful to all irrigation components if not duly prepared. The following steps will guide you in safe winterizing. Follow them strictly. When to Winterize The best time to winterize is the morning after the last day of the irrigation season. Procedure (1) Wash out all corrosive material residues. Fill the fertilizer tanks with fresh water (if you

have some fertilizer left for next season, fill a bucket with water and place it instead of the tank), then run the system with a program that will use all the injectors. Ensure that each injector receives at least 20 liters (4 gallons) of water.

(2) Close all manual valves and turn all pumps switches Off. Define the Elgal controller “Not active”.

(3) Disconnect Fertijet’s inlet and outlet pipes from the main pipe and tip over to drain of all contents.

(4) Dismantle all records and bleed all water residues from the Venturi injectors, electrical valves, check valves and other elements as required.

(5) In applications employing main fertilizer NC valves, make sure to dry all the 8mm command hoses, the solenoid valve, and both the upper and lower chambers of each valve.

(6) Open the booster pump’s draining cap (Figure 9) and leave it opened for 1 hour. (7) Verify bleeding of all pipes. (8) Remove one of the probes from the EC-pH sampling cell and drip in 50cc (2 OZ) of

concentrated antifreeze material. Re- fit the probe in place and secure with bolt.

Fertimix User´s Manual

Page 12: User´s Manual - galconc.com · fertilizer control valve, ... ¾ Before attempting any maintenance work on the injectors, close all manual valves at the fertilizer tank outlet

11

Fertimix User´s ManualFertijet Manual

Page 11

(9) Clean the Fertijet of all external residues of corrosive materials. Cover the Fertijet with a sheet. Do not shut controller’s power supply down! – leaving the Elgal controller powered down for an extended period of time may drain the memory backup lithium battery.

Figure 9: Booster Pump Draining Cap

Page 13: User´s Manual - galconc.com · fertilizer control valve, ... ¾ Before attempting any maintenance work on the injectors, close all manual valves at the fertilizer tank outlet

Fertijet Manual

Page 12

Appendix 1 - Electric Drawings

FertJet Electrical diagramefor systems with ~3 booster pump

Circuit C: ~24V

6A circuitbeaker

~

0

Controller'sOutputscircuit

EC-pH3050

L485communic.

device

PS1

R1

SW1Manual Auto

R2

R2

Main valve's output

Max I =3.15A

Max I =0.5A

Max I =0.2A

Max I =0.2A

Circuit A: ~3 mains

PKZ

U,V,W

K1

Circuit B: ~1 mains

6A circuitbeaker

~

24V 200VA(8A Max.load)

K1

R1

LPP110/220

0

Controller'smains

Max I =0.2A

Date: 19/01/02

Fertijet Electrical diagrame - type 1File name: \Drawing1 Draft by:

Fertimix User´s Manual

12

Page 14: User´s Manual - galconc.com · fertilizer control valve, ... ¾ Before attempting any maintenance work on the injectors, close all manual valves at the fertilizer tank outlet

Fertijet Manual

Page 13

FertiJet Electrical diagramefor systems with ~3 booster pump

Circuit C: ~24V

6A circuitbeaker

~

0

Controller'sOutputscircuit

EC-pH3050

L485communic.

device

PS1

SW1Manual Auto

R1

R1

Main valve's output

Max I =3.15A

Max I =0.5A

Max I =0.2A

Max I =1.0A

Circuit A: ~3 mains

PKZ

U,V,W

K1

Circuit B: ~1 mains

6A circuitbeaker

~

24V 200VA(8A Max.load)

K1

0

Controller'smains

Max I =0.2A

Date: 25/01/02

Fertijet Electrical diagrame - type 1File name: \F Draft by:

LPP110/220

A1

A2 A2

A1

PKZM B1

B2

S1

K1

Fertimix User´s Manual

13

Page 15: User´s Manual - galconc.com · fertilizer control valve, ... ¾ Before attempting any maintenance work on the injectors, close all manual valves at the fertilizer tank outlet

Fertijet Manual

Page 14

Fertijet ~3 Booster pump Electric PanelFertijet2.vsd17-12-01Eldar-Shany

R S T PC PRS1

PRS2

powerin3x220v

60HZ 20A

pumppower out

24vAC

Pum

p co

ntro

l

Pres

sost

at 1

1

24

TR1115v

24v

FU14A

K1S1

man. auto.

OL

24v K124v

U V W

R S T U V W

21

22

input 2pump fail

zer o gnd.

phas

e

line

zer o gnd.

phas

e

load

F1 1A F2 1A LPP

120V60Hz

6A

fuse

3.1

5

com

A B C D

A B C D

comm.out

OPT

out

puts

out

out 1

out 2

out 3

out 4

gnd

fuse

3.1

5

com

A B C D

A B C D

comm.out

OPT

out

puts

out

out 5

out 6

out 7

out 8

gnd

fuse

3.1

5

com

A B C D

A B C D

comm.out

OPT

out

puts

out

out 9

out 1

0ou

t 11

out 1

2

gnd

com

A B C D

A B C D

comm.inp

IPT

inpu

ts

out

in 1

in 2

in 3

in 4

gnd

com

A B C D

A B C D

com-anl

APT

anal

og

anl

in 1

in 2

in 3

in 4

gnd

+24v

+24v

mai

n va

lve

fert.

(wat

er)p

ump

mai

n pu

mp

alar

m

fert.

pum

p A

wat

er c

ount

.

pum

p fa

il EC pH

fert.

pum

p B

fert.

pum

p C

com

Elgal outputsconnector Elgal inputs conn. Elgal anl. inputs conn.

LPP= Line Power Protection unit

OL = 3 Phase Over Load Protection

R S T

FU1 S1

man

auto

K1

360mm

500m

m

2 4

1

NYY 5x2.5 5m cable

TR1

24V

230V

OL

LPP

OPT OPT OPT IPT APT

CF CN

FU3-

5A

24V

com

. out

#1

N UGND V W

CNCF

FU2

24vAC PCPR

S1PR

S2

N GND

FU24A

120VElgalpower Connection to

24vac terminalin the Elgalcontroller

Connection toEC/pH unit

FU2

115 V 115 V00

24V

NFU1

TR1Transformer

connection for115V power

pp 3x0.75 5m cable

?

Fertimix User´s Manual

Fertijet - 3 Booster Pump Electric Panel

14

Page 16: User´s Manual - galconc.com · fertilizer control valve, ... ¾ Before attempting any maintenance work on the injectors, close all manual valves at the fertilizer tank outlet

Fertijet Manual

Page 15

Compact Fertigal Electric PanelFertigal5.vsd24-03-99Eldar-Shany

R S T PC PRS1

PRS2

powerin380v

50HZ 10A

pumppower out

24vA

C(fr

om E

lgal

)

Pum

p co

ntro

l

Pres

sost

at 1

1

24

TR1230v

24v

R3E-13 pumps

control unitFU14A

K1S1

man. auto.OL4A

24v K124v

24v

com

m.

out

Elga

l out

AEl

gal o

utB

Elga

l out

C

fert.

val

veB

fert.

val

veA

fert.

val

ve C

U V W

R S T U V W

3 4

21

22

input 2pump fail

zer o gnd.

phas

e

line

zer o gnd.

phas

e

load

F1 1A F2 1A LPP

Elga

l pow

erin

230

v

fuse

3.1

5

com

A B C D

A B C D

comm.out

OPT

out

puts

out

out 1

out 2

out 3

out 4

gnd

fuse

3.1

5

com

A B C D

A B C D

comm.out

OPT

out

puts

out

out 5

out 6

out 7

out 8

gnd

fuse

3.1

5

com

A B C D

A B C D

comm.out

OPT

out

puts

out

out 9

out 1

0ou

t 11

out 1

2

gnd

com

A B C D

A B C D

comm.inp

IPT

inpu

ts

out

in 1

in 2

in 3

in 4

gnd

com

A B C D

A B C D

com-anlAP

T an

alog

anl

in 1

in 2

in 3

in 4

gnd

+24v

+24v

mai

n va

lvefe

rt. (w

ater

)pum

p

mai

n pu

mp

alar

m

fert.

pum

p A

valve

1

wat

er c

ount

.

pum

p fa

il EC pH

fert.

pum

p B

fert.

pum

p C

valve

2

valve

3

valve

4

valve

5

valve

6 com

fert. valves

Elgal outputsconnector Elgal inputs conn. Elgal anl. inputs conn.

LPP= Line Power Protection unit

OL = 3 Phase Over Load Protection

1 2 3

FU1 S1

man

auto

K1

360mm

500m

m

2 4

1

NYY 5x2.5 5m cable

TR1

R3E-1

24V

230V

OL

LPP

OPT OPT OPT IPT APT

CF CN

1 2

input 1watercount.

Compact Fertigal Electric Panel

15

Page 17: User´s Manual - galconc.com · fertilizer control valve, ... ¾ Before attempting any maintenance work on the injectors, close all manual valves at the fertilizer tank outlet

Fertijet Manual

Page 16

Appendix B – Mechanical Drawings

No. Catalog No. Description 1 2101112121 ¾” Elbow 2 2041000101 Check valve + record 3 2102512083 Trans. female conn. ¾” > ½” 4 2170240080 Complete Sirai valve 50 Hz 5 2170240082 Complete Sirai valve 60 Hz 6 2112008002 Adjustable ½” valve 7 2101056082 Pipe connection 8 2171002415 Sirai coil ~24V 50 Hz 8 2171002416 Sirai coil ~24V 60 Hz 9 2171910120 Diaphragm (New) 9 2171910110 Diaphragm (Old)

10 2171002420 Sirai valve housing 11 01120010 Distributor manifold 4 outlets 12 0910311000 Venturi injector skeleton 350 l/h (90 GPH) 13 01120005 Mixing manifold 4 inlets 14 01120100 Booster pump inlet adaptor (800 series) 14a 01120105 Booster pump inlet adaptor (400 series) 15 01120110 Water + fertilizer outlet fitting (800 series) 15a 01120115 Water + fertilizer outlet fitting (400 series) 16 2301732161 Flexible pipe fitting 32mm » 1½” 17 2010500020 Mechanical bearing 16mm

1

2

3

4-5

6

7

11

12

13

14

16 15

19

20-23

8

10

9

16

Page 18: User´s Manual - galconc.com · fertilizer control valve, ... ¾ Before attempting any maintenance work on the injectors, close all manual valves at the fertilizer tank outlet

Fertijet Manual

Page 17

20 2010006405 Booster pump ~3 400V 50 Hz 1.5 HP 21 2010006805 Booster pump ~3 400V 50 Hz 2.5 HP 22 2010006403 Booster pump ~3 400/220V 60 Hz 1.5 HP 23 2010006802 Booster pump ~1 120V 60 Hz 2.0 HP 24 2010006803 Booster pump ~3 400/220V 60 Hz 2.5 HP

17

17

Page 19: User´s Manual - galconc.com · fertilizer control valve, ... ¾ Before attempting any maintenance work on the injectors, close all manual valves at the fertilizer tank outlet

Fertijet Manual

Page 18

Appendix C – Performance Specifications Table C-1: Injector Combinations (EC-pH injector calculated but not counted) Comb. No. 350 l/h

(90 GPH) type 1020 l/h

(300 GPH) Type

Total Booster Q L/h (GPM)

Nutrients Injection Capacity

Acid IA

1 2 0 3000-4000 (13-18) 350 l/h 350 2 3 0 4500-5500 (20-24) 700 l/h 350 3 4 0 5600-7000 (25-30) 1050 l/h 350 4 5 0 6700-8500 (30-37) 1,400 l/h 350 5 1 1 6500-7900 (29-35) 1,050 l/h 350 6 2 1 7400-9100 (33-40) 1,400 l/h 350 7 1 2 10400-12800 (45-56) 2,100 l/h 350 8 1 3 14500-18000 (64-80) 3,150 l/h 350 9 0 4 18000-22000 (80-97) 3,150 l/h 1020

Table C-2: Pumps vs. Downstream Pressure – Valid Combinations

Downstream Pressure 1.5 HP 2.5-3 HP 7.5 HP 2.5 bar 2,3,4 N/A N/A 3 bar 2,3 3-7 N/A 4 bar 1,2 2-6 9 5 bar 1 1,2,3,5 8,9

The injection rate represents maximum injection capacity, with mainline flow rate as a factor. Using two injectors to inject a higher rate of fertilizer is common whenever necessary, therefore the chart below simply represents the total injection capacity of each combination.

Injection rate

0

5

10

15

20

25

30

35

40

30 40 60 100 180 340

Mainline flow M3/H

l / m3

123 and 54 and 678 and 9

18