Initial Remarks
ICC#32
• worked on SOVT-2 (SIMS#1/#2) data of OD 63
• mainly used ESAC/HSC data pool products
• re-processing done at HSC many times
• analysis results subject to change with each iteration
• my first acquaintance with data pool product analysis (tutorials and exchange of experience needed)
• inconsistencies found between SOVT-2, SIMS#1 and SIMS#2
PACS Chopper Angular Calibration (CAPs)• ground calibration needs to be redone in orbit (zero gravity)
• measure mechanical zero point offset
• open-loop measurement (SFT) used for static/dynamical properties
• new CAPs available, based on previous versions (JIDE & IDL by UK, JS)‐ had to be split into two CAPs (Jython error: too many code lines)
Marku
s Nie
lbock – P
AC
S S
OV
T-2
Analy
sis / CA
Ps
ICC#32
PACS PHOT Linearity in Flux
• standard PHOT dithered point source photometry AOT used
• during PV phase: sequence of objects covering large flux range
• during SOVT-2: one AOR – tracking on SSO Ceres
• full analysis still pending (no flux analysis)
Marku
s Nie
lbock – P
AC
S S
OV
T-2
Analy
sis / CA
Ps
ICC#32
• OOL product present but empty
• TC history only available for SIMS#1, missing for SOVT-2 and SIMS#2
Results (based on dp-pacs 361):
PACS PHOT Linearity in FluxM
arku
s Nie
lbock – P
AC
S S
OV
T-2
Analy
sis / CA
Ps
ICC#32
SOVT-2SIMS#1
SIMS#2
PACS PHOT Linearity in Flux
• standard PHOT dithered point source photometry AOT used
• during PV phase: sequence of objects covering large flux range
• during SOVT-2: one AOR – tracking on SSO Ceres
• full analysis still pending
Marku
s Nie
lbock – P
AC
S S
OV
T-2
Analy
sis / CA
Ps
ICC#32
• OOL product present but empty
• TC history only available for SIMS#1, missing for SOVT-2 and SIMS#2
Results:
• labelling of CS 1 and 2 swapped in Status product (PACS SPR 1052)
• pointing check for moving object confusing:What is the correct coordinate of Ceres for the date of observing?How were the coordinates simulated for the SOVT-2 data?3 different results (HSPOT, JPL webtool, HIPE: ephemerides, horizons)5” discrepancy between JPL and HIPE (PACS SPR 1347, aberration corr.)
PACS PHOT Linearity in FluxM
arku
s Nie
lbock – P
AC
S S
OV
T-2
Analy
sis / CA
Ps
ICC#32
• used prototype ExtractCS task to separate calibration block
• both arrays agree well
• two frames do not align (cf. presentation of MS yesterday)
PACS PHOT Linearity in FluxM
arku
s Nie
lbock – P
AC
S S
OV
T-2
Analy
sis / CA
Ps
ICC#32
CS1 CS2
indication for improper flagging of chopper transitions
PACS PHOT Linearity in FluxM
arku
s Nie
lbock – P
AC
S S
OV
T-2
Analy
sis / CA
Ps
ICC#32
• first target frame is not on the correct position (still slewing)
• positions of first frame in blue/green and red data differ (Why? Timing?)• issue of applying masks correctly or even findBlocks task?
• invalidates subsequent processing steps
PACS PHOT Linearity in Flux
ICC#32
Marku
s Nie
lbock – P
AC
S S
OV
T-2
Analy
sis / CA
Ps
• target frame 155 affected by nodding transition
• is this taken care of?
PACS PHOT Linearity in Flux
ICC#32
Marku
s Nie
lbock – P
AC
S S
OV
T-2
Analy
sis / CA
Ps
• last two blue/green target frames: no chopping
• total number of target frames differ between blue/green and red
ICC#32
Marku
s Nie
lbock – P
AC
S S
OV
T-2
Analy
sis / CA
Ps
• after dithAvg(): first off frame determines coordinate of first average
PACS PHOT Linearity in Flux
PACS PHOT Linearity in Flux
ICC#32
Marku
s Nie
lbock – P
AC
S S
OV
T-2
Analy
sis / CA
Ps
• after nodAvg(): first off frame produces third nod position?
PACS PHOT Linearity in Flux
ICC#32
Marku
s Nie
lbock – P
AC
S S
OV
T-2
Analy
sis / CA
Ps
• tried to produce level 2 data
• products and FITS files do not contain WCS information (PACS SPR 1392)
blue exposure map
red exposure map
Concluding remarks
ICC#32
Marku
s Nie
lbock – P
AC
S S
OV
T-2
Analy
sis / CA
Ps
• still seems some work necessary
• pointing/tracking seems to be (approximately) correct
• final confirmation only possible after elimination of 5” offset
• When will the various issues/SPRs be followed up?
• How do we assure exchange of vital information on data processing?
PACS Chopper automatic PID tuning
• iteration on small modifications around four PID parameters
• BBIDs “abused” for parameter set indexing
• originally designed for Commissioning Phase
15 following observations lost (SPEC) – “NACK” in event log detected PV phase clone will be changed accordingly if needed
chopper was switched off during SOVT-2 at end of measurement
Marku
s Nie
lbock – P
AC
S S
OV
T-2
Analy
sis / CA
Ps
ICC#32
• OOL product present but empty
• TC history only available for SIMS#1, missing for SOVT-2 and SIMS#2
(cf. PICC-MA-TN-002, PICC-MA-TR-076)
PACS Chopper automatic PID tuning• SOVT-2 data did not contain diagnostic HK
• SPEC HK indicates observation was fully executed
Marku
s Nie
lbock – P
AC
S S
OV
T-2
Analy
sis / CA
Ps
ICC#32
• only present in latest re-processing during SIMS#2