    Protect your upstream personnel and investment

    while increasing distribution reliabilityUsing expulsion fuses

    where ignition of

    combustible materials,

    dry grass or worse, gases,

    are a high potential risk,

    is now unnecessary

    because of Eatons Cooper

    Power Systems ELF

    current-limiting fuse.

    Dont take that risk with

    your upstream personnel;

    preventing even one

    accident is well worth

    the investment.

    The ELF dropout fuse is a fullyself-contained design thatoperates silently and eliminatesexpulsive showers associatedwith expulsion fuse operation.The full-range current-limitingrating ensures reliable operationof over-loads and fault currents.These features make it suitablefor areas where a high firehazard exists. The ELF-LR fusehas been granted permanent

    exemption by the CaliforniaDepartment of Forestry andFire Protection (CAL FIRE)from power line distributionpole clearance requirements the trimming or removal ofbrush or trees from right-of-wayto reduce a potential fuelsource when the fuse isinstalled in the field accordingto manufacturers specifications,assuring that no gas, sparks,or debris is emitted.

    Because of this assurance,you get all of the following

    benefits:

    Increased safety to linepersonnel during circuitenergization operations

    Increased safety for personsworking in flammable orconfined areas of worksites

    Reduced hazards and fire risk

    Design

    Moreover, the universal fitdesign of the ELF fuse makesit an easy retrofit into anyindustry standard interchange-able cutout. Because it hasa drop-open design, operationis clearly indicated and faultlocating is simplified. In longcable runs of upstream oil andgas applications, this will greatlyreduce time and money spenton upkeep of the system.Once the fuse has operated,maintenance personnel cansimply use a clampstick toremove the suspended fuse.

    Energy-limitingDesign

    With its full range, current-limiting characteristics testedto ANSI/IEEE requirements

    C37.40, C37.41, and C37.47,the ELF fuse operates toclear both low- and high-currentfaults quickly. The elementconstruction, with separablelow-current and high-currentsections, controls peak arcvoltage levels, and limitscurrent and energy (I2t)let-through levels duringthe clearing operation.

    This energy-limiting designallows for:

    Reduced system damagefrom high energy faults inheavy loading upstreamapplications

    Uninterrupted power qualitydue to sustained system-wide voltage support ontrips caused by faultswithin the system

    Potential reduction in arcflash concerns and requiredpersonal protectionequipment (PPE)

    ELFSelf-containedCutout-Mounted Fuse

  • 8/10/2019 Pa 132007 En

    2/2

    Eaton and Cooper Power Systems arevaluable trademarks of Eaton in the U.S.and other countries. You are not permittedto use these trademarks without the priorwritten consent of Eaton.

    All other trademarks are propertyof their respective owners.

    Eaton1000 Eaton BoulevardCleveland, OH 44122United StatesEaton.com

    Eatons Cooper Power Systems Business2300 Badger DriveWaukesha, WI 53188cooperpower.com

    2014 EatonAll Rights ReservedPrinted in USAPublication No. PA132007ENSeptember 2014

    Perfect for upstream oil fieldpower distribution

    Self-contained designincreases safety duringcircuit energization

    Operates silently while

    eliminating expulsiveshowers associatedwith expulsion fuses

    Universal fit design allowseasy retrofit of existingexpulsion fuses

    Drop-open design clearlyindicates fault location,greatly reducing time andmoney spent on systemupkeep

    Typical applications

    Upstream oil & gasexploration powerdistribution

    Dry, grassy areas, orwherever combustible

    materials are in closeproximity to fuse operation

    Transformer protection

    Capacitor protection

    Personnel safety

    Underground taps

    Single-Barrel ELF Double-Barrel ELF Triple-Barrel ELF

    Discover innovative solutions with Eatons Cooper Power

    Systems ELF self-contained cutout-mounted fuse for

    upstream power distribution applications.

    Expulsion Fuse

    ELF Fuse

    Test parameters:6400 A RMS symmetrical.

    Test results:ELF Current-Limiting Fuses Reduce Energy Let-Through

    by a Factor of 9 over Expulsion Fuses.

    Product scope

    The ELF fuse voltage ratingsrange from 8.324 kV whileour single-, double-, and triple-barrel fuse designs expandamperage ratings from 680A for easy coordination. Thisexpanded offering allows oneto easily choose fuses that

    work for almost any system.

    Moreover, the ELF fuse isdesigned to be mounted in15 kV and 27 kV, (110 kV,125 kV or 150 kV BIL) ratedinterchangeable opendistribution cutouts includingMacLean/S&C Type XS,Hubbell Type Cand ABBType ICXcutouts. Designsfor use in 35 kV (170 kV BIL)rated ABB Series Vcutoutsare also available.

    Supplementary products andservices for upstream powerdistribution and overhead lineapplications

    Type L cutouts

    Single-phase pole-mounttransformers

    Reclosers

    Overhead voltage regulators

    Manual disconnect switches

    Distribution arresters

    Fault indicators