P-type Separation System
Parameter List
PrintedBook No.
Sep 2008
1810897-02 V 4
right to make changes at any time without
Alfa Laval reserves the prior notice.Any comments regarding possible errors and omissions or suggestions for improvement of this publication would be gratefully appreciated.
Copies of this publication can be ordered from your local Alfa Laval company.
Published by: Alfa Laval Tumba AB Marine & Diesel Equipment SE - 147 80 Tumba Sweden
© Copyright Alfa Laval Tumba AB 2008.
Contents
1 Parameter Setting...............................3
2 Installation Parameters ..................7
3 Process Parameters .......................11
4 Factory Set Parameters...............15
5 Sequence Diagram ..........................185.1 Separation Sequence....................20
1810897-02
1810897-02
P-TYPE SEPARATION SYSTEM PARAMETER LIST 1 PARAMETER SETTING
1 Parameter Setting
The parameters are set in the operator panel for the different separator systems, and for different conditions within the systems.
There are three parameter types: Installation, Process, and Factory Set parameters.
The parameters are initially set at installation. The process parameters can also be set as required during operation.
Parameters not in use are not displayed.
The parameter list in this booklet is valid for PA and PU systems.
General principle
The ‘ENTER’ button is used to:
– enter into a parameter list
– enter into a parameter
– accept/store a new parameter value.
The ‘+’ or the ‘–’ buttons are used to change the value flashing in the display window.
1810897-02 3
1 PARAMETER SETTING P-TYPE SEPARATION SYSTEM PARAMETER LIST
P0
04
21
DB
To change parameters, proceed as follows:
1 Push the ‘ENTER’ button.
‘Time to discharge P1 60’ is shown. ‘P1 is the parameter, and ‘60’ is the set value.
The ‘1’ of the ‘P1’ is flashing.
2 Push the ‘+’ button until the number of the parameter you wish to program appears in the display window.
The chosen parameter number is now flashing.
3 Push the ‘ENTER’ button.
The chosen parameter number is now shown on the left side in the display. The parameter value is shown flashing on the right side of the display.
4 Push the ‘+’ or ‘–’ button to change the parameter value.
5 Push the ‘ENTER’ button. The new value is stored.
The parameter number is now flashing.
6 Push the ‘+’ or ‘–’ button to go to the next parameter to be changed.
7 To leave the list, push the ‘+’ and the ‘–’ buttons at the same time. The display shows ‘Standst.’ or, when in operation, the trigger value to the left, and time remaining to discharge on the right.
INFO
OP
ENTER
HEATER
SEPARATION
STOP
DISCHARGE
OP A CTIVE
ALARM
EPC-50
16 15 10
TT PT PT
Heater on/off push-button
Sludge discharge push-button
LED for stop sequence running (yellow)
Control program on/off push-button
LED for control program running (green)
LED for heater (green)
Enter push-button
Alarm reset LED for common main alarm (red)
LED showing this panel active
Schematic diagram with position LEDs
Display window – push- button
+ push- button
4 1810897-02
P-TYPE SEPARATION SYSTEM PARAMETER LIST 1 PARAMETER SETTING
The following lists are available for viewing from a menu in the EPC-50 control unit:
• Install (parameters)
• Factory (parameters)
• Alarms
• Test
For detailed information see each list.
To open the menu and select a list, proceed as follows:
1 Push the ‘ENTER’ button. The process parameter list is now open.
2 Push the ‘+’ button until ‘End’ is displayed.
3 Push the ‘ENTER’ button and the ‘+’ button at the same time. ‘Install’ will show flashing on the display.
4 Use the ‘+’ button to select a list.
5 Use the ‘Enter’ button to enter into the selected list.
6 To leave the list, push the ‘+’ and the ‘–’ buttons at the same time.
7 To leave the menu, press the ‘+’ button repeatedly until ‘Exit’ is displayed. Push the ‘ENTER’ button.
1810897-02 5
1 PARAMETER SETTING P-TYPE SEPARATION SYSTEM PARAMETER LIST
6 1810897-02
P-TYPE SEPARATION SYSTEM PARAMETER LIST 2 INSTALLATION PARAMETERS
2 Installation Parameters
e Description
= English
erman
panish
ench
lian
rtuguese
nish
wedish
Language. All information displayed on the operators panel is shown in the selected language.
d (Dis) Power supply frequency
r (Clar)
(Pur)
Separation mode
0
5
5
5
The installation parameters must be set before the initial start-up and before process parameters are set. These parameters rarely need to be adjusted again. If a new parameter value is to be stored, it is necessary to go through the whole list, and confirm at the end.
NOTE
Alfa Laval cannot be held responsible for injuries and damage caused by usage of parameter values which are not in proximity to the factory values set by Alfa Laval.
Parameter Factory set value
Plant set value
Rang
In 1 GB/US GB/US
DE = G
ES = S
FR = Fr
IT = Ita
PT = Po
FI = Fin
SE = S
In 2 50 Disable
50 Hz
60 Hz
In 3 Pur Clarifie
Purifier
In 4 625 100, 15
600, 60
610, 61
625, 63
1810897-02 7
2 INSTALLATION PARAMETERS P-TYPE SEPARATION SYSTEM PARAMETER LIST
than one EPC on attbus
Separator identity
If more than one separator system is connected to the internal Sattbus communication, each system must be given its own identity (1 or 2 or 3 etc.).
Speed sensor
Vibration sensor
OP remote
Sludge pump used
I/O expansion board used
Celsius or Fahrenheit
heater)
ctrical heater)
(steam heater)
Heater type
, 16, 22, 24, 36, 40, 65, 72, 86, 96, 98, 0, 112, 126, 128, 4 Kw
El heater size
Activated when El. is selected in In 18
seconds Steam-valve run time
Activated when Steam is selected in In 18
e Description
In 5 1 1 – 9
If moresame S
In 6 No No
Yes
In 7 No No
Yes
In 8 No No
Yes
In 15 No No
Yes
In 16 No No
Yes
In 17 °C °C
°F
In 18 No No (no
El. (ele
Steam
In 19 56 7, 8, 1450, 56, 100, 11130, 14
In 20 120 0 – 999
Parameter Factory set value
Plant set value
Rang
8 1810897-02
P-TYPE SEPARATION SYSTEM PARAMETER LIST 2 INSTALLATION PARAMETERS
econds Alarm delay time
seconds Change-over valve V1 temp. alarm delay
Prevents false alarm due to any fluctuations in temperature caused by valve actions.
Change-over valve V1 off at extra alarm
When the extra alarm input is used, action at alarm can be none (No) or feed off (Yes).
Power fail alarm used
If this alarm is not required, set the parameter to ‘No’.
= Fieldbus
Internet
Type of computer communication board used
Internet IP address, part 1
Internet IP address, part 2
Internet IP address, part 3
Internet IP address, part 4
Flow rate in m3/h per hour or US gallons per hour.
The feed flow measurement, based on inlet pressure, can be displayed in one of these ways.
e Description
In 22 15 0 – 30 s
In 23 15 0 – 240
In 24 No No
Yes
In 25 Yes No
Yes
In 26 No No
ExtPC
I-Net =
In 27 0 0 – 255
In 28 0 0 – 255
In 29 0 0 – 255
In 30 0 0 – 255
In 32 m3/h m3/h
USG/h
Parameter Factory set value
Plant set value
Rang
1810897-02 9
2 INSTALLATION PARAMETERS P-TYPE SEPARATION SYSTEM PARAMETER LIST
10 1810897-02
P-TYPE SEPARATION SYSTEM PARAMETER LIST 3 PROCESS PARAMETERS
3 Process Parameters
Description
s Time to discharge
Diesel Oil
ediate Fuel Oil
Fuel Oil
cating Oil for Trunk
icating Oil for Cross
Oil type
(xxx represents viscosity in Cst at 50°C)
OP in control
ote OP
nd using Sattbus
n Computer Board
ote switches
Control location
OPloc is standard. OPrem, ExtPC and RemSW are shown only when installed.
00 hours
Countdown service timer
Action is to be taken when the timer reaches 0.
The process parameters can be adjusted easily and as often as required, even during operation, to meet changes in the operating conditions, e.g. time between sludge discharges, oil temperature, alarm points.
NOTE
Regularly check the condition of the bowl. If there is no noticeable amount of hard sludge in the sludge space, the discharge interval may be increased by 30 minutes at a time. The total discharge interval must not exceed three times the factory set value in order to avoid an uneven build-up of sludge.
Parameter Factory set value
Plant set value
Range
Pr 1 See table on page 15
1 – 999 minute
Pr 2 HF380 MDO = Marine
GO = Gas Oil
IFxxx = Interm
HFxxx= Heavy
LO TP = LubriPiston Engines
LO CH = LubrHead Engines
Pr 3 OPloc OPloc = Local
OPrem = Rem
Rmind = Remi
ExtPC = Exter
RemSw = Rem
Pr 5 0.0 0.0 = Not used
0.1 to 10.0x10
1810897-02 11
3 PROCESS PARAMETERS P-TYPE SEPARATION SYSTEM PARAMETER LIST
e elapsed
text 1...9
Type of service
When service timer Pr5 reaches 0, an alarm is given and a message shown
wn
de
Keys to special functions used by service engineer
When Pr7 is set to 1 during normal operation, the actual timer is displayed if the ‘+’ button is pressed once.
ure sensor disabledHigh oil pressure limit
(cleaned oil outlet)
Low oil pressure limit
sure sensor High feed pressure limit
r Low feed pressure limit
Low pressure indicates insufficient flow. The low pressure limit must be higher than any static pressure and lower than normal pressure.
or disabled
HFO/LO high temp. limit
HFO/LO low temp. limit
Description
Pr 6 0 0 = service tim
1 – 9 = Service
Pr 7 0 Information
1 = timers sho
2 = service mo
Pr 10 3.0 0.0 – 5.0 bar 0.0 = oil press
Pr 11 0.8 0.0 – 5.0 bar
Pr 14 3.0 0.0 – 5.0 bar 0.0 = feed presdisabled
Pr 15 0.1 0.00 – 5.00 ba
Pr 16 105 °C 0 – 115 °C or
0 – 255 °F
0 = Temp sens
Pr 17 85 °C 0 – 115 °C or
0 – 255 °F
Parameter Factory set value
Plant set value
Range
12 1810897-02
P-TYPE SEPARATION SYSTEM PARAMETER LIST 3 PROCESS PARAMETERS
Pr 18 95 °C 0 – 110 °C or
0 – 240 °F
0 = Temp sensor disabled
HFO/LO setpoint1)
Setpoint for feed temperature is valid only when a temperature controller is installed in the EPC.
Pr 19 40 °C 0 – 115 °C or
0 – 255 °F
DO high temp. limit
Pr 20 20 °C 0 – 115 °C or
0 – 255 °F
DO low temp. limit
Pr 21 30 °C 0 – 110 °C or
0 – 240 °F
DO setpoint1)
Setpoint for feed temperature is valid only when a temperature controller is installed in the EPC.
Pr 22 40 10 – 500 % P-constant1)
Preset value based on experience with Alfa Laval Heatpac heaters.
Pr 23 1.2 0.1 – 10.0 minutes I-constant1)
Preset value based on experience with Alfa Laval Heatpac heaters.
Pr 25 2 0 – 240 seconds Sludge tank alarm delay (during Ti 68)
Pr 27 0 0 – 9 Separators in series. Purifier and Clarifier.
The value is taken from In5 for clarifier. Must be the same value in both clarifier and purifier.
Pr 28 2 1 – 4 Sludge discharge signal from purifier to clarifier.
0 = No discharge signal to clarifier
1 = Every purifier discharge
2 = Every 2nd purifier discharge
3 = Every 3rd purifier discharge
4 = Every 4th purifier discharge
Pr 31 -0.05 + 1.00 bar PT1 decrease at discharge
Alarm limit if In6 = No
1) Parameter appears only when heater board installed.
Parameter Factory set value
Plant set value
Range Description
1810897-02 13
3 PROCESS PARAMETERS P-TYPE SEPARATION SYSTEM PARAMETER LIST
14 1810897-02
P-TYPE SEPARATION SYSTEM PARAMETER LIST 4 FACTORY SET PARAMETERS
4 Factory Set Parameters
e Description
00 rpm sor disabled
High speed
00 rpm Low speed
0 rpm Speed decrease during discharge
Alarm limit if In6 = Yes
.50 sensor disabled
Shutdown limit for separator spindle amplitude
.50 Vibration prewarning
.50 Vibration sensor adjustment zero point. Zero point should be within 1.5 + Fa 18
When expected feedback from a timer is given, the timer is interrupted and the next timer starts.
If feedback is not received within the preset time, an alarm is given.
Timers for start are 50 - 59.
Timers for operation are 60 - 69.
Timers for discharge are 70 - 79.
Timers for stop are 80 - 89.
If pump is started independent of Alfa Laval starter, X6:4 - X40 must be connected to a free closing contact at the external pump contactor.
Parameter Factory set value
Plant set value
Rang
Fa 10 See table page 17
0 – 13 30 = sen
Fa 11 See table page 17
0 – 12 0
Fa 12 300 0 – 2 00
Fa 16 0.30 0.00 – 20.00 =
Fa 17 0.20 0.00 – 2
Fa 18 0.5 0.00 – 2
1810897-02 15
4 FACTORY SET PARAMETERS P-TYPE SEPARATION SYSTEM PARAMETER LIST
e Description
seconds Feed pump on
inutes Separator start-up
inutes Heater on (temp. feedback)
Temperature above low limit (Pr 17, Pr 20) expected to confirm that the heater works normally.
minutes
standby
Max. time for ‘Standby‘ mode. During ‘Standby‘ mode, the system is waiting for an order to start the process sequence. The process sequence is started with a push of the start button.
When Ti 55 = 0 the process starts without delay.
seconds Discharge – after a power blackout to prevent a period between discharges greater than Pr 1. (This is not a proper discharge, since the bowl is empty.)
econds Pause = Draining of operating system
econds Close bowl
econds Sealing water added (does not apply in clarifier mode)
econds Oil feed on. Max 60 secs. Interrupted by PT4
econds Tank draining
minutes Time between discharges. This is the same as Pr 1. If one is changed, the other one is automatically changed.
econds Oil feed off. Oil outlet pressure below low limit (Pr 11) expected.
Seconds Displacement of oil
econds Tank draining
0 seconds Discharge
econds Pause = Draining of operating system
econds Closing water
econds Sealing water (does not apply in clarifier mode)
econds Feed on (not when STOP is ordered)
econds Tank draining
Parameter Factory set value
Plant set value
Rang
Ti 50 60 2 – 300
Ti 52 4 0 – 60 m
Ti 53 15 0 – 60 m
Ti 55 See table on page 17
0 – 120
0 = no
Ti 60 5.0 0.1 – 30
Ti 61 15 0 – 30 s
Ti 62 See table on page 17
0 – 60 s
Ti 63 See table on page 17
0 – 60 s
Ti 64 30 0 – 60 s
Ti 66 10 0 – 30 s
Ti 68 See Pr1 page 17
0 – 300
Ti 70 15 0 – 30 s
Ti 72 See table on page 17
0 – 300
Ti 73 10 0 – 30 S
Ti 74 3.0 0.1 – 5.
Ti 75 15 0 – 30 s
Ti 76 15 0 – 60 s
Ti 77 See table on page 17
0 – 60 s
Ti 79 30 0 – 60 s
Ti 80 10 0 – 30 s
16 1810897-02
P-TYPE SEPARATION SYSTEM PARAMETER LIST 4 FACTORY SET PARAMETERS
seconds Heater off.
Addition of water. This is so that the bowl is kept filled during stop sequence (does not apply in clarifier mode).
inutes Temperature decrease
The EPC switches the separator motor off.
Decreasing oil feed temperature greater than 5 °C expected.
If Ti 85 = 0, no temperature control.
inutes Check motor off
seconds Pump off. Timer interrupted by feedback signal.
inutes Waiting for zero speed.
Ti 63 Ti 72 Ti 77 Fa 10 Fa 11
20 10 10 - -
5 6 5 13300 11000
9 10 9 11000 9900
e Description
Parameters depending on separator size
Ti 82 5 0 – 300
Ti 85 5 0 – 30 m
Ti 86 3 0 – 30 m
Ti 87 60 0 – 300
Ti 89 30 0 – 60 m
Separator size Pr 1 Ti 55 Ti 62
P 100, 150
P 600, 605, 610, 615
30 60 40
P 625 60 0 15
P 635 60 0 15
Parameter Factory set value
Plant set value
Rang
1810897-02 17
5 SEQUENCE DIAGRAM P-TYPE SEPARATION SYSTEM PARAMETER LIST
5 Sequence Diagram
rt Separation
is activated if not so within the timer
61 62 63 4) 64 66 5) 68
1.0 s 15 s 15/40 s s6) 30 s 10 s 60 m
7)
8)
NOTE
Note! This diagram is valid for normal operation only. See the flow chart on page 22 for a more detailed sequence description.
Preparation for start Sta
Timer 50 1)
1) Interrupted by Contactor feedback signal
52 2)
2) Interrupted when speed > low limit (if speed sensor is present)
53 3)
3) Temperature should increase with 5°C or above low limit. Alarm
55 60
4) Not used for Clarifier5) Only if In15 = yes
Time 60 s 4 m 15 m 0/60 s 5.0/
6) Depending on separtor size. See table on page 17.
Feed pump motor
Separator motor
SV 15
SV 16
7) 1 second every 5 minutes
SV 10
V1
Sludge pump
8) Sludge pump activated for 5 seconds every 30 minutes
18 1810897-02
P-TYPE SEPARATION SYSTEM PARAMETER LIST 5 SEQUENCE DIAGRAM
86 5) 87 6) 89 7)
3 m 60 s 30 m
Flow rates for P 100, P 150, P 600, P 605, P 610, P 615
SV10: 8.0 l/m
SV15: 18 l/m
SV16: 0.9 l/m
Flow rates for P 625, P 635
SV10: 15.0 l/m
SV15: 11.0 l/m
SV16: 2.8 l/m
Discharge Stop
Timer 70 1)
1) Ti 70 is interrupted by feedback signal (low pressure on PT4)Ti 79 is not used in stop sequence discharge if Purifier
72 2)
2) Not used for clarifier
73 3)
3) Only if In15 = yes
74 75 76 77 2) 79 1) 80 3) 82 2) 85 4)
4) Interrupted by decreasing temperature5) Interrupted by decreasing speed (if speed sensor is present)6) Interrupted by feedback signal (Feed Pump Motor) 7) Interrupted by Zero speed (if speed sensor is present)
Time 15 s s 8) 10 s 3.0 s 15 s 15 s s 8)
8) Depending on separtor size. See table on page 17.
10 s 10 s 5 s 5 m
Feed pump motor
Separator motor
SV 15
SV 16 9)
9) 5 minutes after separator motor is stopped, SV16 is activated for 1 second
SV 10
V1
Sludge pump
1810897-02 19
5 SEQUENCE DIAGRAM P-TYPE SEPARATION SYSTEM PARAMETER LIST
Alarms
system gets sufficient
r
‘Oil backpressure PT4 – LOW‘
Alarm is given if no pressure response in oil outlet within Ti 64.
. every 5 minutes.
During separation all necessary functions are supervised.
5.1 Separation Sequence
Timer Action
Start
Ti 60 = 5 sec.
SV 15
Discharge
To ensure that the operating water before closing.
Ti 61 = 15 sec. Draining of operating wate
Ti 62 = 15 or 40 sec.
SV 16
Bowl closing
Ti 63 = 5 or 20 sec.
SV 10
Filling of sealing water
Sep
aration
Ti 64 = 30 sec.
V 1
Feed on to separator
Ti 68 = 60 or 30 min.
V1 (SV16)
Separation
Closing water is fed for 1 sec
20 1810897-02
P-TYPE SEPARATION SYSTEM PARAMETER LIST 5 SEQUENCE DIAGRAM
Alarms
s.
‘OIL PRESSURE PT4 HIGH DURING Ti70‘.
Alarm given if no pressure feedback.
ier mode)
ure
d)
urifier mode)
ecrease.
p. decrease below low
‘Temperature - NOT DECREASING‘
If temp. not decreased within Ti 85.
off feedback
Timer Action
Disch
arge
Ti 70 = 15 sec. Feed off.
Oil outlet pressure decrease
Ti 72 = 6 sec.
SV10
Displacement water
Ti 74 = 3.0 sec.
SV15
Discharge
Ti75 = 15 sec. Pause
Ti 76 = 15 sec.
SV16
Closing water
Ti77 = 5 or 10 sec. Sealing water (only in purif
Ti 79 = 10 sec.
V1
Feed on.
Stabilizing of flow and press
Ti 80 = 10 sec. Drain of sludge tank (if use
Sto
p
Ti 82 = 5 sec.
SV10Heater off
Water to the bowl (only in p
Ti 85 = 5 min.
Separator motor off
Waiting for oil feed temp. d
Timer is interrupted when temlimit.
Ti 86 = 3 min. Check motor off
Ti 87 = 60 sec.
Feed pump off
Timer is interrupted by pump(contactor response)
Ti 89 = 30 min. Waiting for zero speed
1810897-02 21
5 SEQUENCE DIAGRAM P-TYPE SEPARATION SYSTEM PARAMETER LIST
Stop?
Man. discharge?
No
o
No
Yes
Yes
Standst.
ot as clarifier)
Push Separation
Process Start
Ti64 Feed on
Ti68 Time to discharge
Ti68 elapsed?
N
Discharge
Assembled according to
manual?
No
Yes
Ti50-53 Sep. start and temp
check
Ti55 Standby.Push
Separation to continue
Ti 60 Discharge
Ti62 Bowl closing
Ti63 Sealing water (N
EPC 50 Sequences
Yes
Separation
22 1810897-02
P-TYPE SEPARATION SYSTEM PARAMETER LIST 5 SEQUENCE DIAGRAM
Ti66
Stop
Ti82 Water into bowl.Heater off
Standst.
Ti86 Heater cooling. Check
motor off
Ti85 Sep. motor off. Check
decreasing temp
Ti87 Pump off
Ti89 Waiting for 0-speed
Feed n
Discharge
Stop
Yes
Stop?
Ti70 Feed off
Ti 72 Displacement
of oil
Ti74 Discharge
Ti76 Closing water
Ti79o
No
1810897-02 23
5 SEQUENCE DIAGRAM P-TYPE SEPARATION SYSTEM PARAMETER LIST
24 1810897-02