Outdoor Unit: 26-TON PURY-EP312YSNU-A (-BS) (-BS) 208-230V Product Data Sheet.pdfOutdoor Unit:...

5
Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Job Name: System Reference: Date: Outdoor Unit: 26-TON PURY-EP312YSNU-A (-BS) (Consists of One PURY-EP168YNU-A (-BS), One PURY-EP144YNU-A (-BS) and One CMY-R300NCBK Twinning Kit) UNIT OPTION Standard Model PURY-EP312YSNU-A Seacoast (BS) Model PURY-EP312YSNU-A-BS ACCESSORIES Twinning Kit (required) CMY-R300NCBK Joint Kit for details see Pipe Accessories Submittal BC Controller (required) for details see BC Controller Submittals Low Ambient Kit for details see Low Ambient Kit Submittal Snow/Hail Guards Kit for details see Snow/Hail Guards Kit Submittal Panel Heater Kit for details see Panel Heater Kit Submittal Specifications System Module 1 Module 2 Unit Type PURY-EP312YSNU-A (-BS) PURY-EP168YNU-A (-BS) PURY-EP144YNU-A (-BS) Nominal Cooling Capacity Btu/h 312,000 168,000 144,000 Nominal Heating Capacity Btu/h 350,000 188,000 160,000 Guaranteed Operating Range *1 Cooling (Outdoor) *2 Refer to Module Data 23~126°F (-5~52°C) Heating (Outdoor) *3 -13~60°F (-25~15.5°C) Extended Operating Range *4 Heating (Outdoor) -25~60°F (-31.5~15.5°C) External Dimensions (H x W x D) In. (mm) Refer to Module Data 71-5/8 x 68-29/32 x 29-5/32 (1,818 x 1,750 x 740) 71-5/8 x 48-7/8 x 29-5/32 (1,818 x 1,240 x 740) Net Weight Lbs. (kg) 1522 (690) 807 (366) 715 (324) External Finish Refer to Module Data Pre-coated galvanized steel sheet (+powder coating for -BS type) <MUNSELL 5Y 8/1> Electrical Power Requirements Voltage, Phase, Hertz Refer to Module Data 3-phase 3-wire 460 V ±10% 60 Hz Minimum Circuit Ampacity (MCA) A 26 22 Maximum Overcurrent Protection (MOP) A 40 35 Recommended Fuse Size A 40 35 Recommended Minimum Wire Size AWG (mm) 8 (8.4) 8 (8.4) Short-circuit Current Rating (SCCR) kA 5 5 Piping Diameter (Brazed) (In. / mm) Liquid (High Pressure) 1-1/8 (28.58) Brazed Refer to System Data Gas (Low Pressure) 1-5/8 (41.28) Brazed Max. Total Refrigerant Line Length Ft. 3,936 Max. Refrigerant Line Length (Between ODU & IDU) Ft. 541 Max. Control Wiring Length Ft. 1,640 Indoor Unit Total Capacity 50~150% of outdoor unit capacity Refer to System Data Model / Quantity P05~P96/2~50 Sound Pressure Levels dB(A) 67.0/69.0 Refer to System Data Sound Power Levels dB(A) 87.0/88.5 Fan Type x Quantity Refer to Module Data Propeller fan x 2 Propeller fan x 2 Airflow Rate CFM 14,850 9,550 External Static Pressure In. WG Selectable; 0, 0.12, 0.24, 0.32 in.WG; factory set to 0 in.WG Compressor Operating Range 7.5% to 100% Refer to System Data Compressor Type x Quantity Refer to Module Data Inverter scroll hermetic compressor x 1 Inverter scroll hermetic compressor x 1 Refrigerant Refer to Module Data R410A 23 lbs + 12 oz (10.8 kg) R410A 23 lbs + 12 oz (10.8 kg) Protection Devices High Pressure Refer to Module Data High pressure sensor, High pressure switch at 4.15 MPa (601 psi) Inverter Circuit (Comp. / Fan) Over-heat protection, Over-current protection Fan Motor Over-current protection AHRI Ratings (Ducted/Non-Ducted) EER 10.7 / 10.9 Refer to System Data IEER 22.8 / 26.1 COP 3.20 / 3.36 SCHE 20.6 / 23.8 NOTES: Nominal cooling conditions (Test conditions are based on AHRI 1230) Indoor: 80°FD.B./67°FW.B. (26.7°CD.B./19.4°CW.B.), Outdoor: 95°FD.B. (35°CD.B.) Nominal heating conditions (Test conditions are based on AHRI 1230) Indoor: 70°FD.B. (21.1°CD.B.), Outdoor: 47°FD.B./43°FW.B. (8.3°CD.B./6.1°CW.B.) ** Each individual module requires a separate electrical connection. Refer to electrical data for each individual module. 1. Harsh weather environments may demand performance enhancing equipment. Ask your Mitsubishi Electric representative for more details about your region 2. For details on extended cooling operation range down to -10° F DB, see Low Ambient Kit Submittal 3. When applying product below -4°F, consult your design engineer for cold climate application best practices, including the use of a backup source for heating 4. Unit will continue to operate in extended operating range, but capacity is not guaranteed OUTDOOR VRF HEAT PUMP WITH HEAT RECOVERY SYSTEM

Transcript of Outdoor Unit: 26-TON PURY-EP312YSNU-A (-BS) (-BS) 208-230V Product Data Sheet.pdfOutdoor Unit:...

Page 1: Outdoor Unit: 26-TON PURY-EP312YSNU-A (-BS) (-BS) 208-230V Product Data Sheet.pdfOutdoor Unit: 26-TON PURY-EP312YSNU-A (-BS) (Consists of One PURY-EP168YNU-A (-BS), One PURY-EP144YNU-A

Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

Job Name:System Reference: Date:

Outdoor Unit: 26-TON PURY-EP312YSNU-A (-BS)(Consists of One PURY-EP168YNU-A (-BS), One PURY-EP144YNU-A (-BS) and One CMY-R300NCBK Twinning Kit)

UNIT OPTION Standard Model PURY-EP312YSNU-A Seacoast (BS) Model PURY-EP312YSNU-A-BS

ACCESSORIES Twinning Kit (required) CMY-R300NCBK Joint Kit for details see Pipe Accessories Submittal BC Controller (required) for details see BC Controller Submittals Low Ambient Kit for details see Low Ambient Kit Submittal Snow/Hail Guards Kit for details see Snow/Hail Guards Kit Submittal Panel Heater Kit for details see Panel Heater Kit Submittal

Specifications System Module 1 Module 2

Unit Type PURY-EP312YSNU-A (-BS) PURY-EP168YNU-A (-BS) PURY-EP144YNU-A (-BS)

Nominal Cooling Capacity Btu/h 312,000 168,000 144,000

Nominal Heating Capacity Btu/h 350,000 188,000 160,000

Guaranteed Operating Range *1Cooling (Outdoor) *2

Refer to Module Data

23~126°F (-5~52°C)

Heating (Outdoor) *3 -13~60°F (-25~15.5°C)

Extended Operating Range *4 Heating (Outdoor) -25~60°F (-31.5~15.5°C)

External Dimensions (H x W x D) In. (mm) Refer to Module Data 71-5/8 x 68-29/32 x 29-5/32 (1,818 x 1,750 x 740)

71-5/8 x 48-7/8 x 29-5/32 (1,818 x 1,240 x 740)

Net Weight Lbs. (kg) 1522 (690) 807 (366) 715 (324)

External Finish Refer to Module Data Pre-coated galvanized steel sheet (+powder coating for -BS type) <MUNSELL 5Y 8/1>

Electrical Power Requirements Voltage, Phase, Hertz

Refer to Module Data

3-phase 3-wire 460 V ±10% 60 Hz

Minimum Circuit Ampacity (MCA) A 26 22

Maximum Overcurrent Protection (MOP) A 40 35

Recommended Fuse Size A 40 35

Recommended Minimum Wire Size AWG (mm) 8 (8.4) 8 (8.4)

Short-circuit Current Rating (SCCR) kA 5 5

Piping Diameter (Brazed) (In. / mm)Liquid (High Pressure) 1-1/8 (28.58) Brazed

Refer to System Data

Gas (Low Pressure) 1-5/8 (41.28) Brazed

Max. Total Refrigerant Line Length Ft. 3,936

Max. Refrigerant Line Length (Between ODU & IDU) Ft. 541

Max. Control Wiring Length Ft. 1,640

Indoor UnitTotal Capacity 50~150% of outdoor unit capacity

Refer to System DataModel / Quantity P05~P96/2~50

Sound Pressure Levels dB(A) 67.0/69.0Refer to System Data

Sound Power Levels dB(A) 87.0/88.5

Fan

Type x Quantity

Refer to Module Data

Propeller fan x 2 Propeller fan x 2

Airflow Rate CFM 14,850 9,550

External Static Pressure In. WG Selectable; 0, 0.12, 0.24, 0.32 in.WG; factory set to 0 in.WG

Compressor Operating Range 7.5% to 100% Refer to System Data

Compressor Type x Quantity Refer to Module Data Inverter scroll hermetic compressor x 1 Inverter scroll hermetic compressor x 1

Refrigerant Refer to Module Data R410A 23 lbs + 12 oz (10.8 kg) R410A 23 lbs + 12 oz (10.8 kg)

Protection Devices

High Pressure

Refer to Module Data

High pressure sensor, High pressure switch at 4.15 MPa (601 psi)

Inverter Circuit (Comp. / Fan) Over-heat protection, Over-current protection

Fan Motor Over-current protection

AHRI Ratings (Ducted/Non-Ducted)

EER 10.7 / 10.9

Refer to System DataIEER 22.8 / 26.1

COP 3.20 / 3.36

SCHE 20.6 / 23.8

NOTES:Nominal cooling conditions (Test conditions are based on AHRI 1230) Indoor: 80°FD.B./67°FW.B. (26.7°CD.B./19.4°CW.B.), Outdoor: 95°FD.B. (35°CD.B.)Nominal heating conditions (Test conditions are based on AHRI 1230) Indoor: 70°FD.B. (21.1°CD.B.), Outdoor: 47°FD.B./43°FW.B. (8.3°CD.B./6.1°CW.B.)** Each individual module requires a separate electrical connection. Refer to electrical data for each individual module.

1. Harsh weather environments may demand performance enhancing equipment. Ask your Mitsubishi Electric representative for more details about your region

2. For details on extended cooling operation range down to -10° F DB, see Low Ambient Kit Submittal3. When applying product below -4°F, consult your design engineer for cold climate

application best practices, including the use of a backup source for heating4. Unit will continue to operate in extended operating range, but capacity is not guaranteed

OUTDOOR VRF HEAT PUMP WITH HEAT RECOVERY SYSTEM

Page 2: Outdoor Unit: 26-TON PURY-EP312YSNU-A (-BS) (-BS) 208-230V Product Data Sheet.pdfOutdoor Unit: 26-TON PURY-EP312YSNU-A (-BS) (Consists of One PURY-EP168YNU-A (-BS), One PURY-EP144YNU-A

Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

Outdoor Unit: PURY-EP312YSNU-A (-BS) – DIMENSIONS

NOTES: SEACOAST PROTECTION • Anti-corrosion Protection: A coating treatment is applied to condenser coil for protection from air contaminants.• Standard: Salt Spray Test Method - no unusual rust development to 480 hours.• Sea Coast (BS): Salt Spray Test Method (JRA 9002) - no unusual rust development to 960 hours.

MEES18K087A

PUR

Y-EP

-T(S

)NU

-A, Y

(S)N

U-A

42

2. EXTERNAL DIMENSIONS R2-Series (High efficiency)

PURY-EP312YSNU-A(-BS) Unit: mm(in)

Fron

t vie

w

Out

door

uni

t 2

Inta

keai

r

Dis

char

ge a

ir

c

b

To B

C c

ontro

ller

aTw

inni

ng p

ipe(

Hig

h pr

essu

re)

e

To B

C c

ontro

ller

<opt

iona

l par

ts>

Twin

ning

pip

e(Lo

w p

ress

ure)

<opt

iona

l par

ts>

df

Left

view

Out

door

uni

t 1

Inta

keai

rIn

take

air

Inta

keai

r

Not

e 1.

Con

nect

the

pipe

s as

sho

wn

in th

e fig

ure

abov

e. R

efer

to th

e ta

ble

abov

e fo

r the

pip

e si

ze.

2. T

win

ning

pip

es s

houl

d no

t be

tilte

d m

ore

than

15

degr

ees

from

the

horiz

onta

l pla

ne.

Be s

ure

to s

ee th

e In

stal

latio

n M

anua

l for

det

ails

of T

win

ning

pip

e in

stal

latio

n.3.

The

pip

e se

ctio

n be

fore

the

Twin

ning

pip

e (s

ectio

n ″a

″and

″b″in

the

figur

e) m

ust h

ave

at le

ast 5

00m

m(1

9-11

/16)

of s

traig

ht s

ectio

n (*

incl

udin

g th

e st

raig

ht p

ipe

that

is s

uppl

ied

with

the

Twin

ning

pip

e).

4. O

nly

use

the

Twin

ning

pip

e by

Mits

ubis

hi (o

ptio

nal p

arts

).

Twin

ning

pip

e co

nnec

tion

size

ø41.

28(1

-5/8

)

CM

Y-R

300N

CBK

PURY

-EP31

2YSN

U-A(-

BS)

PURY

-EP16

8YNU

-A(-BS

)PU

RY-EP

144Y

NU-A(

-BS)

ø28.

58(1

-1/8

)

Low

pres

sure

d or

fHi

gh pr

essu

rec

or e

Uni

t mod

el

Twinn

ing p

ipe~O

utdo

or u

nitEP

144

ø22.

2(7/

8)ø2

8.58

(1-1

/8)

EP16

8ø2

2.2(

7/8)

ø28.

58(1

-1/8

)a b

High

pre

ssur

eLo

w pr

essu

re

Comp

onen

t unit

name

Out

door

uni

t 1Pa

ckag

e un

it na

me

Out

door

Twi

nnin

g Ki

t(opt

iona

l par

ts)

BC c

ontro

ller

~Twi

nnin

g pi

pe

Out

door

uni

t 2

1750

(68-

15/1

6)74

0(29

-3/1

6)12

40(4

8-7/

8)30

(1-3

/16)

1818(71-5/8)

0000005101.BOOK 42 ページ 2019年3月5日 火曜日 午後6時1分

Page 3: Outdoor Unit: 26-TON PURY-EP312YSNU-A (-BS) (-BS) 208-230V Product Data Sheet.pdfOutdoor Unit: 26-TON PURY-EP312YSNU-A (-BS) (Consists of One PURY-EP168YNU-A (-BS), One PURY-EP144YNU-A

Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

Module 1: PURY-EP168YNU-A (-BS) – DIMENSIONS

NOTES: SEACOAST PROTECTION • Anti-corrosion Protection: A coating treatment is applied to condenser coil for protection from air contaminants.• Standard: Salt Spray Test Method - no unusual rust development to 480 hours.• Sea Coast (BS): Salt Spray Test Method (JRA 9002) - no unusual rust development to 960 hours.

MEES18K087A

PUR

Y-EP-T(S)NU

-A, Y(S)N

U-A

39

2. EXTERNAL DIMENSIONS R2-Series (High efficiency)

PURY-EP168YNU-A(-BS) Unit: mm(in)

1 2 43 5 6 7 8NO.

(740)(29-3/16)

132(

5-1/

4)65

0(25

-5/8

)14

8(5-

7/8)

84(3-5/16) 90(3-9/16)

129(5-1/8)144(5-11/16)

109

207(

8-3/

16)

256(

10-1

/8)

135(5-3/8)

54(2-3/16)

740(29-3/16)

831(

32-3

/4)

831(

32-3

/4)

19.5

19.5

(13/

16)

70(2-13/16)

150(5-15/16)

600=150×4

1750

(68-

15/1

6)49

(1-1

5/16

)

185(7-5/16)

152(

6)

1515(59-11/16)3031818(71-5/8)

172(

6-13

/16)

216(

8-9/

16)

166

110(4-3/8)

29.5 681(678~684) 29.5

80

685(

27)

768(

30-1

/4)

653(

25-3

/4)

150(

5-15

/16)

9479

181

795(

31-5

/16)

795(

31-5

/16)

80(3

-3/1

6)

20(1

3/16

)54

592(

23-5

/16)

54(2

-3/1

6)

20(1

3/16

)

(3-3/1

6)

(1-3/16)(1-3/16) (26-13/16)(26-3/4~26-15/16)

(6-9/16)

(7-3/16)

(3-3/4)(3-1/8)

(4-5/16)

(11-15/16)

(13/16

)

(23-5/8)=(5-15/16)×4

(2-3/1

6)

Contr

ol bo

x

34

7

Intak

eair

Intak

eair

Disc

harge

air

5

68

Intak

eair

Intak

eair

2×7-

ø4.6

(3/1

6) H

ole

(Mak

e ho

le a

t the

pla

stic

fan

guar

d fo

r sno

w ho

od a

ttach

men

t)<S

now

hood

atta

chm

ent h

ole>

Top

view

1

Serv

icepa

nel

2

(Mounting pitch)

Botto

m v

iew

(Mou

ntin

g pi

tch)

Fron

t vie

wLe

ft si

de v

iew

Rea

r vie

w

(Mou

ntin

g pi

tch)

2×3-

14(9

/16)

×20(

13/1

6) O

val h

ole

Refri

gera

nt

serv

ice v

alve

<Hig

h pr

essu

re>

Refri

gera

nt

serv

ice v

alve

<Low

pre

ssur

e>

Transf

ormer b

ox

Con

nect

ing

pipe

spe

cific

atio

ns

Not

e 1.

Plea

se re

fer t

o th

e ne

xt p

age

for i

nfor

mat

ion

rega

rdin

g ne

cess

ary

spac

ing

arou

nd th

e un

it an

d fo

unda

tion

wor

k.2.

At b

razi

ng o

f pip

es, w

rap

the

refri

gera

nt s

ervi

ce v

alve

with

wet

clo

th a

nd k

eep

the

tem

pera

ture

of r

efrig

eran

t se

rvic

e va

lve

unde

r 120

°C(2

48°F

).

Mod

elD

iam

eter

Ref

riger

ant p

ipe

Serv

ice

valv

e

ø28.5

8(1-1/

8)ø22

.2(7/8)

Brazed

*1 ø2

8.58(1

-1/8)

EP16

8Hi

gh pr

essu

reLo

w pre

ssure

ø28.58

(1-1/8)

Brazed

High

pres

sure

Low

press

ure

*1 C

onne

ct th

e re

frige

rant

pip

e to

the

serv

ice

valv

eac

cord

ing

to th

e In

stal

latio

n M

anua

l.

For tr

ansm

ission

cable

s

For w

ires

For p

ipes

Usa

geSp

ecifi

catio

ns

Front

throu

gh ho

leBo

ttom

throu

gh ho

leFro

nt thr

ough

hole

Front

throu

gh ho

le

Botto

m thr

ough

hole

Botto

m thr

ough

hole

Front

throu

gh ho

le

148(5

-7/8)

× 84(3

-5/16

) Kno

ckou

t hole

ø62.7

(2-1/2

) or ø

34.5(

1-3/8)

Knoc

kout

hole

ø43.7

(1-3/4

) or ø

22.2(

7/8) K

nock

out h

ole

ø65(2

-9/16

) Kno

ckou

t hole

ø5

2(2-1/

16) K

nock

out h

ole

ø34(1

-3/8)

Knoc

kout

hole

150(5

-15/16

) × 94

(3-3/4

) Kno

ckou

t hole

ø34(1

-3/8)

Knoc

kout

hole

Botto

m thr

ough

hole

0000005101.BOOK 39 ページ 2019年3月5日 火曜日 午後6時1分

Page 4: Outdoor Unit: 26-TON PURY-EP312YSNU-A (-BS) (-BS) 208-230V Product Data Sheet.pdfOutdoor Unit: 26-TON PURY-EP312YSNU-A (-BS) (Consists of One PURY-EP168YNU-A (-BS), One PURY-EP144YNU-A

Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

Module 2: PURY-EP144YNU-A (-BS) – DIMENSIONS

NOTES: SEACOAST PROTECTION • Anti-corrosion Protection: A coating treatment is applied to condenser coil for protection from air contaminants.• Standard: Salt Spray Test Method - no unusual rust development to 480 hours.• Sea Coast (BS): Salt Spray Test Method (JRA 9002) - no unusual rust development to 960 hours.

MEES18K087A

PUR

Y-EP-T(S)NU

-A, Y(S)N

U-A

37

2. EXTERNAL DIMENSIONS R2-Series (High efficiency)

PURY-EP96, 120, 144YNU-A(-BS) Unit: mm(in)

1 2 43 5 6 7 8NO.

740(29-3/16)

70(2-13/16)150(5-15/16)

85(3-3/8)85(3-3/8)

130(5-1/8)

150

18(3

/4)

1204

(47-

7/16

)18

1240

(48-

7/8)

110(4-3/8)

(740)(29-3/16)

185(7-5/16)29.5 681(678~684) 29.5

9479

181

160(

6-5/

16)

243(

9-5/

8)15

012

8(5-

1/16

)

125

132(

5-1/

4)20

7(8-

3/16

)25

6(10

-1/8

)

109

129(5-1/8)

84(3-5/16) 90(3-9/16)

54(2-3/16)

135(5-3/8)

20(1

3/16

)54

592(

23-5

/16)

54(2

-3/1

6)

20(1

3/16

)

148(

5-7/

8)

152(

6)

216(

8-9/

16)

166

144(5-11/16)303 1515(59-11/16)

1818(71-5/8)

90(3

-9/1

6)10

60(4

1-3/

4)90

(3-9

/16)

172(

6-13

/16)

(3-3/4)(3-1/8)

(5-1

5/16

)

(6-9/16)

(7-3/16)

(26-13/16)(26-3/4~26-15/16) (1-3/16)(11-15/16)

(4-5/16)

(4-15

/16)

(2-3/1

6)

(3/4

)

(5-15/16)

(1-3/16)

2

5

68

(Mounting pitch)

Botto

m v

iew

(Mou

ntin

g pi

tch)

2×2-

14(9

/16)

×20(

13/1

6) O

val h

ole

1

Contr

ol box

34

7

Serv

icepa

nel

Intak

eair

Intak

eair

Disch

arge a

ir

Intak

eair

Intak

eair

2×6-

ø4.6

(3/1

6) H

ole

(Mak

e ho

le a

t the

pla

stic

fan

guar

d fo

r sno

w ho

od a

ttach

men

t)<S

now

hood

atta

chm

ent h

ole>

Top

view

Fron

t vie

wLe

ft si

de v

iew

Rea

r vie

w

Refri

gera

nt

serv

ice va

lve<H

igh p

ress

ure>

Refri

gera

nt

serv

ice va

lve<L

ow p

ress

ure>

Transf

ormer

box

Con

nect

ing

pipe

spe

cific

atio

ns

Not

e 1.

Plea

se re

fer t

o th

e ne

xt p

age

for i

nfor

mat

ion

rega

rdin

g ne

cess

ary

spac

ing

arou

nd th

e un

it an

d fo

unda

tion

wor

k.2.

At b

razi

ng o

f pip

es, w

rap

the

refri

gera

nt s

ervi

ce v

alve

with

wet

clo

th a

nd k

eep

the

tem

pera

ture

of r

efrig

eran

t se

rvic

e va

lve

unde

r 120

°C(2

48°F

).

*1 C

onne

ct th

e re

frige

rant

pip

e to

the

serv

ice

valv

eac

cord

ing

to th

e In

stal

latio

n M

anua

l.

Mod

elD

iam

eter

Ref

riger

ant p

ipe

Serv

ice

valv

e

EP12

0ø2

8.58(1

-1/8)

ø19.05

(3/4) B

razed

*1 ø2

8.58(1

-1/8)

EP96

High

pres

sure

Low

pres

sure

ø28.58

(1-1/8)

Brazed

ø22

.2(7/8)

Brazed

*1 EP

144

High

pres

sure

Low

pres

sure

ø22.2(7

/8) Bra

zed *1

For tr

ansm

ission

cable

s

For w

ires

For p

ipesU

sage

Spec

ifica

tions

Fro

nt thr

ough

hole

Botto

m thr

ough

hole

Front

throu

gh ho

le

Front

throu

gh ho

le

Botto

m thr

ough

hole

Botto

m thr

ough

hole

Front

throu

gh ho

le

148(5

-7/8)

× 84(3

-5/16

) Kno

ckou

t hole

ø62.7

(2-1/2

) or ø

34.5(

1-3/8)

Knoc

kout

hole

ø43.7

(1-3/4

) or ø

22.2(

7/8) K

nock

out h

ole

ø65(2

-9/16

) Kno

ckou

t hole

ø5

2(2-1/

16) K

nock

out h

ole

ø34(1

-3/8)

Knoc

kout

hole

150(5

-15/16

) × 94

(3-3/4

) Kno

ckou

t hole

ø34(1

-3/8)

Knoc

kout

hole

Botto

m thr

ough

hole

0000005101.BOOK 37 ページ 2019年3月5日 火曜日 午後6時1分

Page 5: Outdoor Unit: 26-TON PURY-EP312YSNU-A (-BS) (-BS) 208-230V Product Data Sheet.pdfOutdoor Unit: 26-TON PURY-EP312YSNU-A (-BS) (Consists of One PURY-EP168YNU-A (-BS), One PURY-EP144YNU-A

1340 Satellite Boulevard. Suwanee, GA 30024Toll Free: 800-433-4822 www.mehvac.com

Variable Refrigerant Flow (VRF) Multi-Split AC and HPAHRI Standard 1230

Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

FORM# PUHY-EP96TNU-A (-BS) - 201912

Twinning Kit: CMY-R300NCBKUnit: mm (inch)

MEES18K087A

PUR

Y-EP-T(S)NU

-A, Y(S)N

U-A

127

9. OPTIONAL PARTS R2-Series (High efficiency)

9-2. OUTDOOR TWINNING KITThe following optional Outdoor Twinning Kit is needed to use to combine multiple refrigerant pipes. Refer to section "Piping Design" for the details of selecting a proper twinning kit.

Unit: mm (in.)CMY-R200NCBK

<Deformed pipe(Accessory)>

ø25.4(ø1)(Outside diameter)

Twinning pipeø28.58(ø1-3/16)

ø28.58(ø1-3/16)(Outside diameter)

Local brazing

ø22.2(ø7/8)

ø22.2(ø7/8)Pipe cover

(Dot-dashed

ø25.4(ø1)(Outside diameter)

Note 2

High-pressure twinning pipe

Low-pressure twinning pipe

ø19.05(ø3/4)

ø19.05(ø3/4)

ø22.2(ø7/8)

ø28.58(ø1-3/16)ø22.2(ø7/8)(Outside diameter)

ø34.93(ø1-7/16)ø28.58(ø1-3/16)(Outside diameter)

(2 pcs.)(2-1/2)

(3-3/16)

(1-7

/16)

part)

(342)(13-1/2)588(23-3/16)

505(19-29/32)

160(

6-5/

16)

80

35

62

100(3-15/16)

Twinning pipe

±15°

Note:1. Refer to the figure below for

the installation position ofthe twinning pipe.

2. Use the attached pipe to brazethe port-opening of the twinning pipe.

3. Pipe diameter is indicatedby inside diameter.

Slope of the twinning pipesare at an angle within ±15°to the horizontal plane.

Unit: mm (in.)CMY-R300NCBK

(337)(13-5/16)

585(23-1/16)

503(19-13/16)

162(

6-7/

16)

69

35

80 62

ø31.75(ø1-1/4)(Outside diameter)

Local brazing

Pipe cover(Dot-dashed

ø28.58(ø1-3/16)

ø28.58(ø1-3/16)

ø28.58(ø1-3/16)(Outside diameter)

ø34.93(ø1-7/16)Note 2 Twinning pipe ø28.58(ø1-3/16)

(Outside diameter)

(Outside diameter)

High-pressure twinning pipe

<Deformed pipe(Accessory)>

(Outside diameter)

<Deformed pipe(Accessory)>

ø41.28(ø1-11/16)ø34.93(ø1-7/16)

ø22.2(ø7/8)ø19.05(ø3/4)ø28.58(ø1-3/16)

ø19.05(ø3/4)

ø19.05(ø3/4)

Low-pressure twinning pipe

(2 pcs.)

(2-3/4)

(3-3/16)

(1-7/1

6)

(2-1/2)

part)

Twinning pipe

±15°

to the horizontal plane.

Note:1. Refer to the figure below for

the installation position ofthe twinning pipe.

2. Use the attached pipe to brazethe port-opening of the twinning pipe.

3. Pipe diameter is indicatedby inside diameter.

Slope of the twinning pipesare at an angle within ±15°

The angle of the twinning pipe is within ±15° against the horizontal plane. 2. Use the attached pipe to braze the port-opening of the twinning pipe.3. Pipe diameter is indicated by inside diameter.4. Only use the Twinning pipe by Mitsubishi (optional parts) .

Note 1. Reference the attitude angle of the twinning pipe below the fig.

Twinning pipe

±15°

0000005101.BOOK 127 ページ 2019年3月5日 火曜日 午後6時1分

MEES18K087A

PUR

Y-EP-T(S)NU

-A, Y(S)N

U-A

127

9. OPTIONAL PARTS R2-Series (High efficiency)

9-2. OUTDOOR TWINNING KITThe following optional Outdoor Twinning Kit is needed to use to combine multiple refrigerant pipes. Refer to section "Piping Design" for the details of selecting a proper twinning kit.

Unit: mm (in.)CMY-R200NCBK

<Deformed pipe(Accessory)>

ø25.4(ø1)(Outside diameter)

Twinning pipeø28.58(ø1-3/16)

ø28.58(ø1-3/16)(Outside diameter)

Local brazing

ø22.2(ø7/8)

ø22.2(ø7/8)Pipe cover

(Dot-dashed

ø25.4(ø1)(Outside diameter)

Note 2

High-pressure twinning pipe

Low-pressure twinning pipe

ø19.05(ø3/4)

ø19.05(ø3/4)

ø22.2(ø7/8)

ø28.58(ø1-3/16)ø22.2(ø7/8)(Outside diameter)

ø34.93(ø1-7/16)ø28.58(ø1-3/16)(Outside diameter)

(2 pcs.)(2-1/2)

(3-3/16)

(1-7

/16)

part)

(342)(13-1/2)588(23-3/16)

505(19-29/32)

160(

6-5/

16)

80

35

62

100(3-15/16)

Twinning pipe

±15°

Note:1. Refer to the figure below for

the installation position ofthe twinning pipe.

2. Use the attached pipe to brazethe port-opening of the twinning pipe.

3. Pipe diameter is indicatedby inside diameter.

Slope of the twinning pipesare at an angle within ±15°to the horizontal plane.

Unit: mm (in.)CMY-R300NCBK

(337)(13-5/16)

585(23-1/16)

503(19-13/16)

162(

6-7/

16)

69

35

80 62

ø31.75(ø1-1/4)(Outside diameter)

Local brazing

Pipe cover(Dot-dashed

ø28.58(ø1-3/16)

ø28.58(ø1-3/16)

ø28.58(ø1-3/16)(Outside diameter)

ø34.93(ø1-7/16)Note 2 Twinning pipe ø28.58(ø1-3/16)

(Outside diameter)

(Outside diameter)

High-pressure twinning pipe

<Deformed pipe(Accessory)>

(Outside diameter)

<Deformed pipe(Accessory)>

ø41.28(ø1-11/16)ø34.93(ø1-7/16)

ø22.2(ø7/8)ø19.05(ø3/4)ø28.58(ø1-3/16)

ø19.05(ø3/4)

ø19.05(ø3/4)

Low-pressure twinning pipe

(2 pcs.)

(2-3/4)

(3-3/16)

(1-7/1

6)

(2-1/2)

part)

Twinning pipe

±15°

to the horizontal plane.

Note:1. Refer to the figure below for

the installation position ofthe twinning pipe.

2. Use the attached pipe to brazethe port-opening of the twinning pipe.

3. Pipe diameter is indicatedby inside diameter.

Slope of the twinning pipesare at an angle within ±15°

The angle of the twinning pipe is within ±15° against the horizontal plane. 2. Use the attached pipe to braze the port-opening of the twinning pipe.3. Pipe diameter is indicated by inside diameter.4. Only use the Twinning pipe by Mitsubishi (optional parts) .

Note 1. Reference the attitude angle of the twinning pipe below the fig.

Twinning pipe

±15°

0000005101.BOOK 127 ページ 2019年3月5日 火曜日 午後6時1分