May 5, 2011 USCHPA’s Spring CHP Forum
Optimizing Clean Energy Systemswith Thermal Energy Storage and/or
Turbine Inlet Cooling
Dharam V. Punwani, PresidentAvalon Consulting, Inc.
John S. Andrepont, PresidentThe Cool Solutions Company
The Cool Solutions Company
![Page 2: Optimizing Clean Energy Systems with Thermal Energy Storage … · May 5, 2011 USCHPA’s Spring CHP Forum Optimizing Clean Energy Systems with Thermal Energy Storage and/or Turbine](https://reader036.fdocuments.in/reader036/viewer/2022071214/6043256535ea571530346457/html5/thumbnails/2.jpg)
May 5, 2011 USCHPA’s Spring CHP Forum 2
Outline• Introduction
– Clean Energy Systems and Characteristics• Thermal Energy Storage (TES)
– Technologies, Examples and Economics• Turbine Inlet Cooling (TIC)
– Technologies, Examples and Economics• TES-TIC Systems
– Examples, Economics and Comparison with other electric energy storage technologies
• Summary and Conclusions
![Page 3: Optimizing Clean Energy Systems with Thermal Energy Storage … · May 5, 2011 USCHPA’s Spring CHP Forum Optimizing Clean Energy Systems with Thermal Energy Storage and/or Turbine](https://reader036.fdocuments.in/reader036/viewer/2022071214/6043256535ea571530346457/html5/thumbnails/3.jpg)
May 5, 2011 USCHPA’s Spring CHP Forum 3
Introduction• Clean Energy Systems
- Renewable energy systems
- Combined heat & power (cogeneration) systems
- District energy systems
• Clean Energy System Characteristics- Some don’t provide/generate electric or thermal energy
uniformly 24/7, for example: wind-energy, solar-energy,gas-turbine systems
- Electric or thermal energy requirements of the systems served are not uniform 24/7, for example: office buildings, convention centers
![Page 4: Optimizing Clean Energy Systems with Thermal Energy Storage … · May 5, 2011 USCHPA’s Spring CHP Forum Optimizing Clean Energy Systems with Thermal Energy Storage and/or Turbine](https://reader036.fdocuments.in/reader036/viewer/2022071214/6043256535ea571530346457/html5/thumbnails/4.jpg)
May 5, 2011 USCHPA’s Spring CHP Forum 4
IntroductionTES and/or TIC Systems Enhance Efficiency and
Economics of Clean Energy Systems
• Minimize the Impacts- Non-uniformity of Generation- Non-uniformity of Demand
• Optimize Energy Efficiency and Economics
![Page 5: Optimizing Clean Energy Systems with Thermal Energy Storage … · May 5, 2011 USCHPA’s Spring CHP Forum Optimizing Clean Energy Systems with Thermal Energy Storage and/or Turbine](https://reader036.fdocuments.in/reader036/viewer/2022071214/6043256535ea571530346457/html5/thumbnails/5.jpg)
May 5, 2011 USCHPA’s Spring CHP Forum 5
California ISO Report
“Storage will be critical for large scale implementation of sustainable energy.”
– The November 2007 Report “Integration of Renewable Resources”
![Page 6: Optimizing Clean Energy Systems with Thermal Energy Storage … · May 5, 2011 USCHPA’s Spring CHP Forum Optimizing Clean Energy Systems with Thermal Energy Storage and/or Turbine](https://reader036.fdocuments.in/reader036/viewer/2022071214/6043256535ea571530346457/html5/thumbnails/6.jpg)
May 5, 2011 USCHPA’s Spring CHP Forum 6
TES Technologies
• Hot-Water Storage: Stores sensible thermal energy
• Chilled-Fluid Storage: Directly stores sensible heat and indirectly stores electric energy
• Ice Storage: Directly stores latent heat and indirectly stores electric energy
![Page 7: Optimizing Clean Energy Systems with Thermal Energy Storage … · May 5, 2011 USCHPA’s Spring CHP Forum Optimizing Clean Energy Systems with Thermal Energy Storage and/or Turbine](https://reader036.fdocuments.in/reader036/viewer/2022071214/6043256535ea571530346457/html5/thumbnails/7.jpg)
May 5, 2011 USCHPA’s Spring CHP Forum 7
Hot-Water TES Systems
• Use thermal energy available from clean energy systems during periods of low thermal demand
• Provide thermal energy during periods of high thermal energy demand
• Stored hot water could also be used for providing cooling (via absorption chillers) during high cooling demand periods
![Page 8: Optimizing Clean Energy Systems with Thermal Energy Storage … · May 5, 2011 USCHPA’s Spring CHP Forum Optimizing Clean Energy Systems with Thermal Energy Storage and/or Turbine](https://reader036.fdocuments.in/reader036/viewer/2022071214/6043256535ea571530346457/html5/thumbnails/8.jpg)
May 5, 2011 USCHPA’s Spring CHP Forum 8
Hot-Water TES System ExampleFreedom Field, Rockford, IL
• Hot-water storage tanks (2,450 Gallons) store hot water produced by solar thermal panels (175,000 Btu/hr) during periods of sunlight
• Hot water is used for providing space heat during winter
• Hot water is used for operating an absorption chiller (10 tons) that provides chilled water for cooling during summer
![Page 9: Optimizing Clean Energy Systems with Thermal Energy Storage … · May 5, 2011 USCHPA’s Spring CHP Forum Optimizing Clean Energy Systems with Thermal Energy Storage and/or Turbine](https://reader036.fdocuments.in/reader036/viewer/2022071214/6043256535ea571530346457/html5/thumbnails/9.jpg)
May 5, 2011 USCHPA’s Spring CHP Forum 9
Hot-Water TES System ExampleDistrict Energy System at
California State University, Fullerton, CA
• 158 Million Btu TES System (0.5 Million Gallons)
• TES system stores pre-heated steam condensate return for use as feed water for boilers during non-peak heating demand periods, to increase heating capacity during peak demand periods
![Page 10: Optimizing Clean Energy Systems with Thermal Energy Storage … · May 5, 2011 USCHPA’s Spring CHP Forum Optimizing Clean Energy Systems with Thermal Energy Storage and/or Turbine](https://reader036.fdocuments.in/reader036/viewer/2022071214/6043256535ea571530346457/html5/thumbnails/10.jpg)
May 5, 2011 USCHPA’s Spring CHP Forum 10
Chilled-Fluid TES Systems
• Store chilled fluids produced by using thermal or electric energy available from clean energy systems during periods of low thermal or electric demand
• Provide chilled fluid for cooling during periods of high-cooling demand
• Minimize the need to use high-cost electric energy during on-peak periods
![Page 11: Optimizing Clean Energy Systems with Thermal Energy Storage … · May 5, 2011 USCHPA’s Spring CHP Forum Optimizing Clean Energy Systems with Thermal Energy Storage and/or Turbine](https://reader036.fdocuments.in/reader036/viewer/2022071214/6043256535ea571530346457/html5/thumbnails/11.jpg)
May 5, 2011 USCHPA’s Spring CHP Forum 11
Chilled-Fluid TES ExamplePrinceton University CHP
District Energy System, Princeton, NJ
• 40,000 Ton-hr Chilled-Fluid TES System• 14.6 MW simple-cycle CT in CHP service
![Page 12: Optimizing Clean Energy Systems with Thermal Energy Storage … · May 5, 2011 USCHPA’s Spring CHP Forum Optimizing Clean Energy Systems with Thermal Energy Storage and/or Turbine](https://reader036.fdocuments.in/reader036/viewer/2022071214/6043256535ea571530346457/html5/thumbnails/12.jpg)
May 5, 2011 USCHPA’s Spring CHP Forum 12
Chilled-Fluid TES System Example
CHP-Based District Energy System, St. Paul, MN
• Two chilled-water TES systems (65,400 Ton-hrs)
• Store chilled-water produced off-peak by absorption chillers and electric chillers
• Absorption chillers operate on hot-water produced by part of the 25 MW biomass (waste wood)-fired CHP system
![Page 13: Optimizing Clean Energy Systems with Thermal Energy Storage … · May 5, 2011 USCHPA’s Spring CHP Forum Optimizing Clean Energy Systems with Thermal Energy Storage and/or Turbine](https://reader036.fdocuments.in/reader036/viewer/2022071214/6043256535ea571530346457/html5/thumbnails/13.jpg)
May 5, 2011 USCHPA’s Spring CHP Forum 13
TES System EconomicsFactors Affecting the Economics
• Cost of purchased fuel
• Difference between the on-peak and off-peak charge for power demand and electric energy
• Capital cost of the TES system
![Page 14: Optimizing Clean Energy Systems with Thermal Energy Storage … · May 5, 2011 USCHPA’s Spring CHP Forum Optimizing Clean Energy Systems with Thermal Energy Storage and/or Turbine](https://reader036.fdocuments.in/reader036/viewer/2022071214/6043256535ea571530346457/html5/thumbnails/14.jpg)
May 5, 2011 USCHPA’s Spring CHP Forum 14
Gas/Combustion Turbine System CharacteristicsEffect of Hot Weather
• Reduced electric power output, by up to 35%
• Reduced energy efficiency, by up to 8%
• Increased owner cost of buying grid power
![Page 15: Optimizing Clean Energy Systems with Thermal Energy Storage … · May 5, 2011 USCHPA’s Spring CHP Forum Optimizing Clean Energy Systems with Thermal Energy Storage and/or Turbine](https://reader036.fdocuments.in/reader036/viewer/2022071214/6043256535ea571530346457/html5/thumbnails/15.jpg)
May 5, 2011 USCHPA’s Spring CHP Forum 15
Generation Capacity Decreases with Increase in Ambient Temperature; Amount Depends on the CT
Selection
EFFECTS OF COMPRESSOR INLET AIR TEMPERATURE ON GAS TURBINE POWER OUTPUT
80%
85%
90%
95%
100%
105%
50 55 60 65 70 75 80 85 90 95 100COMPRESSOR INLET AIR TEMPERATURE, degrees F
% O
F R
ATED
PO
WER
OLD "FRAME"POWER OUTPUT
Compression Ratio = 10
PERIOD OF GREATEST DEMAND
NEW AERO-DERIVATIVE POWER OUTPUT
Compression Ratio = 30
ISO DESIGN POINT
Up to 19% capacity loss at peak demand for this CT
![Page 16: Optimizing Clean Energy Systems with Thermal Energy Storage … · May 5, 2011 USCHPA’s Spring CHP Forum Optimizing Clean Energy Systems with Thermal Energy Storage and/or Turbine](https://reader036.fdocuments.in/reader036/viewer/2022071214/6043256535ea571530346457/html5/thumbnails/16.jpg)
May 5, 2011 USCHPA’s Spring CHP Forum 16
Up to 4% loss in Energy Efficiency
Heat Rate Increases (i.e. Energy Efficiency Decreases) with Increase in Ambient
Temperature
Note: Heat rate is directly proportional to fuel consumption per kWh and inversely proportional to energy efficiency
979899
100101102103104105
40 50 60 70 80 90 100
Ambient Dry-Bulb Temperature, F
Hea
t Rat
e, P
erce
nt o
f Des
ign
AeroderivativeFrame
![Page 17: Optimizing Clean Energy Systems with Thermal Energy Storage … · May 5, 2011 USCHPA’s Spring CHP Forum Optimizing Clean Energy Systems with Thermal Energy Storage and/or Turbine](https://reader036.fdocuments.in/reader036/viewer/2022071214/6043256535ea571530346457/html5/thumbnails/17.jpg)
May 5, 2011 USCHPA’s Spring CHP Forum 17
Smaller Capacity Systems More Sensitive to Ambient Temperature
Source: Solar Turbines
Capacity Loss of over 21% from ~10,750 kW to ~8,500 kW
Efficiency loss of over 8 % from HR of ~ 11,100 to ~12,000 Btu/kWh
![Page 18: Optimizing Clean Energy Systems with Thermal Energy Storage … · May 5, 2011 USCHPA’s Spring CHP Forum Optimizing Clean Energy Systems with Thermal Energy Storage and/or Turbine](https://reader036.fdocuments.in/reader036/viewer/2022071214/6043256535ea571530346457/html5/thumbnails/18.jpg)
May 5, 2011 USCHPA’s Spring CHP Forum 18
CO2 Emissions (lbs/kWh) During Peak PeriodCalifornia Summer Example
Y-Axis Unit: CO2 Emissions, Lbs/kWh
Source: Scot Duncan Presentation at ASHRAE June 2007
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
12:00
AM
2:00 A
M4:0
0 AM
6:00 A
M8:0
0 AM
10:00
AM
12:00
PM
2:00 P
M4:0
0 PM
6:00 P
M8:0
0 PM
10:00
PM
SCE
PG&E
SDG&E
![Page 19: Optimizing Clean Energy Systems with Thermal Energy Storage … · May 5, 2011 USCHPA’s Spring CHP Forum Optimizing Clean Energy Systems with Thermal Energy Storage and/or Turbine](https://reader036.fdocuments.in/reader036/viewer/2022071214/6043256535ea571530346457/html5/thumbnails/19.jpg)
May 5, 2011 USCHPA’s Spring CHP Forum 19
Fuel Use* Carbon Footprint
System Carbon Footprint
Cogeneration/CHP Lowest**
CT in Combined-Cycle
CT in Simple-Cycle
Steam-Turbine Highest***
* Total fuel used for generating electric and thermal energy
** Utilizes thermal energy in the CT exhaust to meet some of the thermal energy needs
*** Old plants used primarily for peak shaving
![Page 20: Optimizing Clean Energy Systems with Thermal Energy Storage … · May 5, 2011 USCHPA’s Spring CHP Forum Optimizing Clean Energy Systems with Thermal Energy Storage and/or Turbine](https://reader036.fdocuments.in/reader036/viewer/2022071214/6043256535ea571530346457/html5/thumbnails/20.jpg)
May 5, 2011 USCHPA’s Spring CHP Forum 20
TIC Systems
• Minimize the detrimental impacts of hot weather on CT system performance
• Reduce the owner cost for buying power from grid
• Minimize the operation of low-efficiency power generation system connected to the grid during hot weather
Benefits
• Cool the inlet air to the GT/CT system
![Page 21: Optimizing Clean Energy Systems with Thermal Energy Storage … · May 5, 2011 USCHPA’s Spring CHP Forum Optimizing Clean Energy Systems with Thermal Energy Storage and/or Turbine](https://reader036.fdocuments.in/reader036/viewer/2022071214/6043256535ea571530346457/html5/thumbnails/21.jpg)
May 5, 2011 USCHPA’s Spring CHP Forum 21
Turbine Inlet Cooling
• Cooling the inlet air before or during compression in the compressor that supplies high-pressure compressed air to the combustor of a combustion turbine
![Page 22: Optimizing Clean Energy Systems with Thermal Energy Storage … · May 5, 2011 USCHPA’s Spring CHP Forum Optimizing Clean Energy Systems with Thermal Energy Storage and/or Turbine](https://reader036.fdocuments.in/reader036/viewer/2022071214/6043256535ea571530346457/html5/thumbnails/22.jpg)
May 5, 2011 USCHPA’s Spring CHP Forum 22
TIC System Technologies
Two Categories
• Reduce Temperature of Inlet Air to Compressor
• Reduce Temperature of Inlet Air During Compression
![Page 23: Optimizing Clean Energy Systems with Thermal Energy Storage … · May 5, 2011 USCHPA’s Spring CHP Forum Optimizing Clean Energy Systems with Thermal Energy Storage and/or Turbine](https://reader036.fdocuments.in/reader036/viewer/2022071214/6043256535ea571530346457/html5/thumbnails/23.jpg)
May 5, 2011 USCHPA’s Spring CHP Forum 23
TIC System TechnologiesReduce Inlet Air Temperature
• Direct Evaporation- Wetted Media- Fogging
• Indirect Evaporation• Chilled Fluid
- Indirect Heat Exchange- Direct Heat exchange
• Chilled Fluid in TES• Hybrid
- Some combination of two or more cooling technologies
![Page 24: Optimizing Clean Energy Systems with Thermal Energy Storage … · May 5, 2011 USCHPA’s Spring CHP Forum Optimizing Clean Energy Systems with Thermal Energy Storage and/or Turbine](https://reader036.fdocuments.in/reader036/viewer/2022071214/6043256535ea571530346457/html5/thumbnails/24.jpg)
May 5, 2011 USCHPA’s Spring CHP Forum 24
TIC System Technologies
Reduce Inlet-Air Temperature During Compression
• Wet Compression (or Fog Overspray)
![Page 25: Optimizing Clean Energy Systems with Thermal Energy Storage … · May 5, 2011 USCHPA’s Spring CHP Forum Optimizing Clean Energy Systems with Thermal Energy Storage and/or Turbine](https://reader036.fdocuments.in/reader036/viewer/2022071214/6043256535ea571530346457/html5/thumbnails/25.jpg)
May 5, 2011 USCHPA’s Spring CHP Forum 25
TIC Example
McCormick PlaceExposition CenterDistrict Energy SystemChicago, Illinois
• Inlet air is cooled for the 3.3 MW CHP system that uses three 1.1 MW gas turbines
• Air is cooled by indirect heat exchange with evaporating ammonia from ammonia chillers
![Page 26: Optimizing Clean Energy Systems with Thermal Energy Storage … · May 5, 2011 USCHPA’s Spring CHP Forum Optimizing Clean Energy Systems with Thermal Energy Storage and/or Turbine](https://reader036.fdocuments.in/reader036/viewer/2022071214/6043256535ea571530346457/html5/thumbnails/26.jpg)
May 5, 2011 USCHPA’s Spring CHP Forum 26
TIC Example
• 318 MW (3 x 106 MW)
• Hybrid TIC system: absorption chillers (8,300 Tons) in series with an electric chiller (1,200 Tons)
Calpine Clear Lake Cogeneration, Pasadena, TX
![Page 27: Optimizing Clean Energy Systems with Thermal Energy Storage … · May 5, 2011 USCHPA’s Spring CHP Forum Optimizing Clean Energy Systems with Thermal Energy Storage and/or Turbine](https://reader036.fdocuments.in/reader036/viewer/2022071214/6043256535ea571530346457/html5/thumbnails/27.jpg)
May 5, 2011 USCHPA’s Spring CHP Forum 27
DOE Survey* Results of CHP Installations with TIC
* Performed by The Cool Solutions Company and Avalon Consulting, Inc (2004)
29Total1Wet Compression1Fogging2Wetted Media4Ammonia Evaporation in Coil
21Chillers (w/ or w/o TES)Number of SystemsTechnology
![Page 28: Optimizing Clean Energy Systems with Thermal Energy Storage … · May 5, 2011 USCHPA’s Spring CHP Forum Optimizing Clean Energy Systems with Thermal Energy Storage and/or Turbine](https://reader036.fdocuments.in/reader036/viewer/2022071214/6043256535ea571530346457/html5/thumbnails/28.jpg)
May 5, 2011 USCHPA’s Spring CHP Forum 28
TIC System EconomicsFactors Affecting the Economics
• Market value of additional power generation capacity and electric energy produced by TIC
• Hourly weather data for the plant location
• TIC Technology
• CT model
• TIC system capital cost
• Cost of purchased fuel
![Page 29: Optimizing Clean Energy Systems with Thermal Energy Storage … · May 5, 2011 USCHPA’s Spring CHP Forum Optimizing Clean Energy Systems with Thermal Energy Storage and/or Turbine](https://reader036.fdocuments.in/reader036/viewer/2022071214/6043256535ea571530346457/html5/thumbnails/29.jpg)
May 5, 2011 USCHPA’s Spring CHP Forum 29
Effect of TIC Technology on Net Capacity Enhancement
Source: White Paper of the Turbine Inlet Cooling Association (2009)
18
41
19
43
4956
5255
-
10
20
30
40
50
60
Net
Out
put E
nhan
cem
ent,
MW
Wetted Media Fogging Electric Chiller WetCompression
95F DB and 80F WB95F DB and 60F WB
Combined-Cycle System: Two 501FD1 and one ST
![Page 30: Optimizing Clean Energy Systems with Thermal Energy Storage … · May 5, 2011 USCHPA’s Spring CHP Forum Optimizing Clean Energy Systems with Thermal Energy Storage and/or Turbine](https://reader036.fdocuments.in/reader036/viewer/2022071214/6043256535ea571530346457/html5/thumbnails/30.jpg)
May 5, 2011 USCHPA’s Spring CHP Forum 30
Effect of TIC Technology on Capital Cost for Incremental Capacity
317 MW Cogeneration System Snapshot at 95oF DB and 80oF WB
Source: White Paper of the Turbine Inlet Cooling Association (2009)
832,941
15,660 14,79795,215
183,421
-
200,000
400,000
600,000
800,000
1,000,000
Cap
acity
Enh
ance
men
t Cap
ital
Cos
t, $/
MW
No Cooling Wetted Media Fogging WetCompression
Electric Chiller
![Page 31: Optimizing Clean Energy Systems with Thermal Energy Storage … · May 5, 2011 USCHPA’s Spring CHP Forum Optimizing Clean Energy Systems with Thermal Energy Storage and/or Turbine](https://reader036.fdocuments.in/reader036/viewer/2022071214/6043256535ea571530346457/html5/thumbnails/31.jpg)
May 5, 2011 USCHPA’s Spring CHP Forum 31
Effect of TIC Technology on Net Increase in Electric Energy Output
Increased generation Relative to uncooled CT
Source: Punwani et al ASHRAE Winter Meeting, January 2001
![Page 32: Optimizing Clean Energy Systems with Thermal Energy Storage … · May 5, 2011 USCHPA’s Spring CHP Forum Optimizing Clean Energy Systems with Thermal Energy Storage and/or Turbine](https://reader036.fdocuments.in/reader036/viewer/2022071214/6043256535ea571530346457/html5/thumbnails/32.jpg)
May 5, 2011 USCHPA’s Spring CHP Forum 32
TES-TIC System Technologies
• Full-Shift: No chiller operated during on-peak periods; only chilled water from TES tanks is used
• Partial-Shift: Chillers as well as chilled water from TES tank are used during on-peak periods
![Page 33: Optimizing Clean Energy Systems with Thermal Energy Storage … · May 5, 2011 USCHPA’s Spring CHP Forum Optimizing Clean Energy Systems with Thermal Energy Storage and/or Turbine](https://reader036.fdocuments.in/reader036/viewer/2022071214/6043256535ea571530346457/html5/thumbnails/33.jpg)
May 5, 2011 USCHPA’s Spring CHP Forum 33
TES-TIC System
• Provides more net electric energy generation capacity during on-peak period than systems without TES
• Reduces chiller installed capacity and capital cost
Benefits
![Page 34: Optimizing Clean Energy Systems with Thermal Energy Storage … · May 5, 2011 USCHPA’s Spring CHP Forum Optimizing Clean Energy Systems with Thermal Energy Storage and/or Turbine](https://reader036.fdocuments.in/reader036/viewer/2022071214/6043256535ea571530346457/html5/thumbnails/34.jpg)
May 5, 2011 USCHPA’s Spring CHP Forum 34
TES-TIC SystemEconomics
TIC w/o TES TIC w/ TES*Chiller plant capacity 31,000 tons 11,000 tonsTES capacity none 190,000 ton-hrsTotal project capital cost ~$75 million ~$45 millionNet power increase (6 h/d) ~140 MW ~170 MWUnit capital cost ~$535/kW ~$265/kW
* Ten GE 7EA CTs (750 MW) in Saudi Arabia
![Page 35: Optimizing Clean Energy Systems with Thermal Energy Storage … · May 5, 2011 USCHPA’s Spring CHP Forum Optimizing Clean Energy Systems with Thermal Energy Storage and/or Turbine](https://reader036.fdocuments.in/reader036/viewer/2022071214/6043256535ea571530346457/html5/thumbnails/35.jpg)
May 5, 2011 USCHPA’s Spring CHP Forum 35
Economics of TES for TIC SystemComparison with Other Multi-hour Electric
Energy Storage SystemsSystem Cost, $/kW Efficiency, % Technology Status
TES for TIC 100 - 500 ~ 100 Commercial
Compressed Air 900 (Target) ~70 Developmental
Pumped Hydro 2,000+ 70-80 Commercial
Flywheel 3,400 80-90 Demonstration
Advanced Battery
4,500 ~70 “Pioneering”
Details are shown in the Appendix
Source: John S. Andrepont, Electric Power 2009
![Page 36: Optimizing Clean Energy Systems with Thermal Energy Storage … · May 5, 2011 USCHPA’s Spring CHP Forum Optimizing Clean Energy Systems with Thermal Energy Storage and/or Turbine](https://reader036.fdocuments.in/reader036/viewer/2022071214/6043256535ea571530346457/html5/thumbnails/36.jpg)
May 5, 2011 USCHPA’s Spring CHP Forum 36
Summary & Conclusions• TES has been successfully deployed for enhancing the energy
efficiency and the economics of numerous clean energy systems
• TIC has been successfully deployed for enhancing the power output, energy efficiency and the economics of numerous CT-based clean energy systems in hot weather/climates
• TES for TIC is a lower cost and a higher-efficiency option for electric energy storage than the proven pumped-hydro and the developing storage systems of compressed-air, flywheels and batteries
• No single Energy Storage technology fits all cases; but TES-TIC is a commercially viable and attractive option.
![Page 37: Optimizing Clean Energy Systems with Thermal Energy Storage … · May 5, 2011 USCHPA’s Spring CHP Forum Optimizing Clean Energy Systems with Thermal Energy Storage and/or Turbine](https://reader036.fdocuments.in/reader036/viewer/2022071214/6043256535ea571530346457/html5/thumbnails/37.jpg)
May 5, 2011 USCHPA’s Spring CHP Forum 37
For Questions or Follow-upContact:
Dharam V. PunwaniPhone: 1-630-983-0883E-mail: [email protected]
orJohn S. AndrepontPhone: 1-630-353-9690E-mail: [email protected]
The Cool Solutions Company
![Page 38: Optimizing Clean Energy Systems with Thermal Energy Storage … · May 5, 2011 USCHPA’s Spring CHP Forum Optimizing Clean Energy Systems with Thermal Energy Storage and/or Turbine](https://reader036.fdocuments.in/reader036/viewer/2022071214/6043256535ea571530346457/html5/thumbnails/38.jpg)
May 5, 2011 USCHPA’s Spring CHP Forum 38
Appendix
Detailed Comparison Between TES-TIC and Other Energy Storage Technologies
![Page 39: Optimizing Clean Energy Systems with Thermal Energy Storage … · May 5, 2011 USCHPA’s Spring CHP Forum Optimizing Clean Energy Systems with Thermal Energy Storage and/or Turbine](https://reader036.fdocuments.in/reader036/viewer/2022071214/6043256535ea571530346457/html5/thumbnails/39.jpg)
May 5, 2011 USCHPA’s Spring CHP Forum 39
Pumped Hydro ES vs. TES-TICPumped Hydro Turbine Inlet CoolingEnergy Storage with CHW TES
Location Michigan Saudi ArabiaYear in operation circa 1990 2005Peak power 1,200 MW 48 MWEnergy storage 9,600 MWh 288 MWhProjected life 30+ years 30+ yearsRound-trip eff. ~70-80% near 100%Classification commercial commercialUnit capital cost $2,000+/kW $83/kWDispatch period 8 hours/day 6 hours/day
![Page 40: Optimizing Clean Energy Systems with Thermal Energy Storage … · May 5, 2011 USCHPA’s Spring CHP Forum Optimizing Clean Energy Systems with Thermal Energy Storage and/or Turbine](https://reader036.fdocuments.in/reader036/viewer/2022071214/6043256535ea571530346457/html5/thumbnails/40.jpg)
May 5, 2011 USCHPA’s Spring CHP Forum 40
Compressed Air ES vs. TES-TICCompressed Air Turbine Inlet CoolingEnergy Storage with CHW TES
Location Iowa Saudi ArabiaYear in operation 201X (planned) 2005Peak power 268 MW 48 MWEnergy storage 1,608 MWh 288 MWhProjected life 20+ years 30+ yearsRound-trip effic’cy ~70% near 100%Classification developmental commercialUnit capital cost $900/kW (target) $83/kWDispatch period 6 hours/day 6 hours/day
![Page 41: Optimizing Clean Energy Systems with Thermal Energy Storage … · May 5, 2011 USCHPA’s Spring CHP Forum Optimizing Clean Energy Systems with Thermal Energy Storage and/or Turbine](https://reader036.fdocuments.in/reader036/viewer/2022071214/6043256535ea571530346457/html5/thumbnails/41.jpg)
May 5, 2011 USCHPA’s Spring CHP Forum 41
Advanced Battery ES vs. TES-TIC“Utility-scale” Na-S Turbine Inlet CoolingAdvanced Batteries with CHW TES
Location West Virginia Saudi ArabiaYear in operation 2006 2005Peak power 1.2 MW 48 MWEnergy storage 7.2 MWh 288 MWhProjected life 15 years 30+ yearsRound-trip effic’cy ~70% near 100%Classification “pioneering” commercialUnit capital cost $4,500/kW $83/kWDispatch period 6 hours/day 6 hours/day
![Page 42: Optimizing Clean Energy Systems with Thermal Energy Storage … · May 5, 2011 USCHPA’s Spring CHP Forum Optimizing Clean Energy Systems with Thermal Energy Storage and/or Turbine](https://reader036.fdocuments.in/reader036/viewer/2022071214/6043256535ea571530346457/html5/thumbnails/42.jpg)
May 5, 2011 USCHPA’s Spring CHP Forum 42
Flywheel ES vs TES-TICFlywheel Turbine Inlet CoolingEnergy Storage with CHW TES
Location New York Saudi ArabiaYear in operation 2011 (1st 20%) 2005Peak power 20 MW 48 MWEnergy storage 5 MWh 288 MWhProjected life 20 years 30+ yearsRound-trip effic’cy ~80-90% near 100%Classification demonstration commercialUnit capital cost $3,440/kW $83/kWDispatch period 15 minutes 6 hours/day