HIGH PRESSURE HOUSING HPH For Temposonics ® R-Series Position Sensors Operating Instruction Operating Instruction

Transcript of Operating Instruction - MTS Sensors: … Instruction. Temposonics ... Ingress protection codes: IP68...

Page 1: Operating Instruction - MTS Sensors: … Instruction. Temposonics ... Ingress protection codes: IP68 ... Open the housing by turning the top counter clockwise.

HIGH PRESSURE HOUSING HPHFor Temposonics® R-Series Position Sensors

Operating InstructionOperating Instruction

Page 2: Operating Instruction - MTS Sensors: … Instruction. Temposonics ... Ingress protection codes: IP68 ... Open the housing by turning the top counter clockwise.

Temposonics®, HPH Operating Instruction

2

Precise position measurement

in high pressure housing

This High Pressure Housing is ATEX EEx approved and UL and cULapproved for use in hazardous locations with Temposonicsâ positionsensors.The ATEX, UL and cUL approvals cover flammable gases, vapors andliquids. This housing is made to fit Temposonics R-seriessensors with analog and digital outputs as well as the S-seriesServoSensorä. Both fixed cable and connector versions can beused.When using a standard sensor in this housing you get a cost effi-cient solution for use in hazardous locations which also allows easysensor replacement.

Safety InstructionsThe sensor must only be used according to the EX-certificate no.Demko 07 ATEX 142619X or UL listing no. 2PD0 See product nameplate for actual approvals.To reduce risk of ignition in hazardous atmospheres, disconnect theequipment from the supply circuit before opening. Keep assembleytightly closed when in operation.For use according to UL-listing, conduit seals must be installed wit-hin 18" of the inclosure. Must be connected to a Class 2 power sup-ply The housing parts must be kept as one unit.

They are not interchangeable with parts from similar housings.Only tools applicable for use in explosive atmosphere must be used.

When mounting the rod in “ZONE 0” it is necessary to prevent anyleakage between “ZONE 0” and the surrounding environment.

The sensor house must be connected to an equipotential bondingsystem or an earthingsystem.

Maintainance & Service:

The housing is maintenance free. If the position sensor inside gets defective, open the housing and replace the sensor and close it again according to the des-cription in this manual.Replace only with approved sensors listed above.

Technical Data:ATEX: II 2 G Ex d IIC T5 Tamb -40°C to +60°C

II 2 D Ex tD 20/A21 IP68 T 100°CITS09ATEX16296XIn accordance with EN 60079-0:2006EN 60079-1:2007, EN 60079-26:2004, EN 60079-0:2006 and EN 61241-1:2004Only with ATEX approved cable glandsClass 1, Division 1, Groups A, B, C, and D hazardous locations, temperatur code T5As to fire electrical shock and explosion hazardous only UL certificated Nr. 2PD0.In accordance with UL 1203 standard.Only with UL approved cable glands

Material: Stainless steel AISI 316L (1.4404)Cable gland thread: M20 x 1,5 or 1/2” NPTIngress protection codes: IP68 (only with IP68 approved cable gland)Approved sensors: G-Series Analog+Digital

L-Series Start/StopR-Series AnalogR-Series ProfibusR-Series CANBUSR-Series SSIR-Series DeviceNet

Moutning flange: M18 x 1,5 or 3/4” - 16UNF - 3Apressure rating: 350 barPeak pressure: 530 barMagnet typ: Ring magnetsLevel measurement: Float on requestsuplly voltage: 24 VDC / 150 mA maximalOperating temperature: -40 °C to +60 °C (Basis T5)

Page 3: Operating Instruction - MTS Sensors: … Instruction. Temposonics ... Ingress protection codes: IP68 ... Open the housing by turning the top counter clockwise.

, HPH Operating Instruction

10 Nm 35 NmM20 x 1,5 cable gland, ATEX 4-8,5 mm cable-Ø, stainless steel CG-816679 7 Nm 12,5 NmM20 x 1,5 cable gland, ATEX 8,5 - 16 mm cable-Ø, stainless steel CG-816609 11,5 Nm 17,5 Nm1/2” NPT cable gland, ATEX 3,4 - 8,4 cable-Ø, nickel plated brass 403 042 10 Nm 10 NmStainless steel nut for flange M18 x 1,5Spannre tool DIN 1018A AMF 80-90 mm6 pol. female connector M16 370 4236 pol. female connector M16, with 10 m PUR-cable 370 423 / 10m 5300527 pol. female connector M16 370 6247 pol. female connector M16, with 10 m PUR-cable 370 624 / 10m 530052HPH rotation adapter for M18, M30x1,5 RTA-M18HPH rotation adapter for 3/4” UNF, 1 1/16 RTA-3/4” UNF-2HPH rotation adapter for 3/4” UNF, 1 1/4” 253961

Ø 13,5

Ø 4,2 oncircle Ø 24Height: 8

Ø 33

Ring magnet OD33Part No. 201 542-2

PA-Ferrit-GF20Weight ca. 14goperating temperature: -40 ... +100∞C

Page 4: Operating Instruction - MTS Sensors: … Instruction. Temposonics ... Ingress protection codes: IP68 ... Open the housing by turning the top counter clockwise.

Temposonics®, HPH Operating Instruction

4

Mounting Discritpion:1.Open the housing by turning the top counter clockwise. When opening after a sen-sor is installed, it is very important to completely loosen the cable gland in order toprotect the cable against twisting and physical damage.

The normal way is that the sensor and the HPH housing are in one order and thenMTS supply the sensor mounted in the WPH housing.Go to step 7.

2.Remove rod or profile from the sensor.Separate the plastic tube from the sensor.

3. Cable gland3.1 Insert the cable through the gland

Page 5: Operating Instruction - MTS Sensors: … Instruction. Temposonics ... Ingress protection codes: IP68 ... Open the housing by turning the top counter clockwise.

Temposonics®, HPH Operating Instruction

5

3.2 Insert the connector through the top.

3.3 Connect to the sensor and insert a bag of Desiccant in the top.

3.4Assemble the top and bottom turning clockwise.

3.5Tighten firmly until the top and bottom flanges come together.

Page 6: Operating Instruction - MTS Sensors: … Instruction. Temposonics ... Ingress protection codes: IP68 ... Open the housing by turning the top counter clockwise.

Temposonics®, HPH Operating Instruction

6

3.6Tighten gable gland according to the manufacturer's specifications.

4.Side mounted cable gland(s)4.1Enter the cable through the gland without tightening.

4.2For cable sizes larger than 7mm or very rigid cables, you may need to remove theouter insulation jacket from inside the cable gland to the connector.

4.3Insert and fasten the sensor.

Page 7: Operating Instruction - MTS Sensors: … Instruction. Temposonics ... Ingress protection codes: IP68 ... Open the housing by turning the top counter clockwise.

Temposonics®, HPH Operating Instruction

7

4.4Make the connections.

4.5Insert a bag of Desiccant in the top.

4.6Assemble the top and bottom turning clockwise and tighten firmly until top andbottom flanges come together. (see fig. 11) Tighten the cable glands according tomanufacturer's specifications.

5.Mount the grounding cable.

Page 8: Operating Instruction - MTS Sensors: … Instruction. Temposonics ... Ingress protection codes: IP68 ... Open the housing by turning the top counter clockwise.

Temposonics®, HPH Operating Instruction

6.Tighten the lock screw with min. 1.5Nm torque.

Page 9: Operating Instruction - MTS Sensors: … Instruction. Temposonics ... Ingress protection codes: IP68 ... Open the housing by turning the top counter clockwise.

MTS Sensor TechnologieGmbH & Co. KGAuf dem Schüffel 958513 Lüdenscheid, GermanyTel. + 49-23 51-95 87 0Fax + 49-23 51-5 64 91E-Mail: [email protected]

MTS Systems CorporationSensors Division3001 Sheldon DriveCary, N.C. 27513, USATel. + 1-919-677-0100Fax + 1-919-677-0200E-Mail: [email protected]

MTS Sensors Technology Corp.737 Aihara-cho, Machida-shi, JapanTel. + 81-42-775-3838Fax + 81-42-775-5516E-Mail: [email protected]

Document Part Number: 20140317 (EN) 03/2014MTS and Temposonics® are registered trademarks of MTS Systems Corporation. All other trademarks are

the property of their respective owners. Printed in Germany. Copyright © 2013 MTS Sensor Technologie GmbH & Co. KG. Alterations reserved. All rights reserved in all

media. No license of any intellectual property rights is granted. The information is subject to change without notice and replaces all data sheets previously supplied. The availability of components on the market is sub-ject to considerable fluctuation and to accelerated technical progress. Therefore we reserve the right to alter

certain components of our products depending on their availability. In the event that product approbations or other circumstances related to your application do not allow a change in components, a continuous supply

with unaltered components must be agreed by specific contract.

Page 10: Operating Instruction - MTS Sensors: … Instruction. Temposonics ... Ingress protection codes: IP68 ... Open the housing by turning the top counter clockwise.

Temposonics®, HPH Betriebsanleitung

Page 11: Operating Instruction - MTS Sensors: … Instruction. Temposonics ... Ingress protection codes: IP68 ... Open the housing by turning the top counter clockwise.

Temposonics®, HPH Betriebsanleitung

Page 12: Operating Instruction - MTS Sensors: … Instruction. Temposonics ... Ingress protection codes: IP68 ... Open the housing by turning the top counter clockwise.

Temposonics®, HPH Betriebsanleitung

Page 13: Operating Instruction - MTS Sensors: … Instruction. Temposonics ... Ingress protection codes: IP68 ... Open the housing by turning the top counter clockwise.

Temposonics®, HPH Betriebsanleitung