Open-source NSE Codes Applied to 40 Gbit/s Soliton Lines KAZUHIRO SHIMOURA Kansai Electric Power...
-
Upload
phoebe-hoover -
Category
Documents
-
view
216 -
download
1
Transcript of Open-source NSE Codes Applied to 40 Gbit/s Soliton Lines KAZUHIRO SHIMOURA Kansai Electric Power...
![Page 1: Open-source NSE Codes Applied to 40 Gbit/s Soliton Lines KAZUHIRO SHIMOURA Kansai Electric Power Co., Japan ECOC2001 ( Oct. 4, 2001 RAI Congress Centre,](https://reader036.fdocuments.in/reader036/viewer/2022062422/56649eb25503460f94bb9b13/html5/thumbnails/1.jpg)
Open-source NSE Codes Applied to 40 Gbit/s Soliton Lines
KAZUHIRO SHIMOURA
Kansai Electric Power Co., JapanECOC2001
( Oct. 4, 2001 RAI Congress Centre, Amsterdam,The Netherlands )
![Page 2: Open-source NSE Codes Applied to 40 Gbit/s Soliton Lines KAZUHIRO SHIMOURA Kansai Electric Power Co., Japan ECOC2001 ( Oct. 4, 2001 RAI Congress Centre,](https://reader036.fdocuments.in/reader036/viewer/2022062422/56649eb25503460f94bb9b13/html5/thumbnails/2.jpg)
CONTENTSCONTENTS
Q-map method and Open-source CodeSimulation Reference System
40 Gbit/s Soliton line design by Q-mapsOptimal strength of dispersion management
Average-dispersion and signal-power design
Merit of the 40 Gbit/s soliton system
![Page 3: Open-source NSE Codes Applied to 40 Gbit/s Soliton Lines KAZUHIRO SHIMOURA Kansai Electric Power Co., Japan ECOC2001 ( Oct. 4, 2001 RAI Congress Centre,](https://reader036.fdocuments.in/reader036/viewer/2022062422/56649eb25503460f94bb9b13/html5/thumbnails/3.jpg)
Nonlinear Schrödinger EquationNonlinear Schrödinger Equation
( by Akira Hasegawa 1973 )( by Akira Hasegawa 1973 )
][ BAz
])1(2
[exp),0(2
0
2
CiTS
Pm
26
1
2 3
3
32
2
2
iA
][2
22
RTi
B
Chirped Gaussian Pulse
Non Linear
Linear
![Page 4: Open-source NSE Codes Applied to 40 Gbit/s Soliton Lines KAZUHIRO SHIMOURA Kansai Electric Power Co., Japan ECOC2001 ( Oct. 4, 2001 RAI Congress Centre,](https://reader036.fdocuments.in/reader036/viewer/2022062422/56649eb25503460f94bb9b13/html5/thumbnails/4.jpg)
Split Step Fourier MethodSplit Step Fourier Method ( by Fred Tappert 1971 )( by Fred Tappert 1971 )
Calculated by Mathematica Ver.4 on Win2000
![Page 5: Open-source NSE Codes Applied to 40 Gbit/s Soliton Lines KAZUHIRO SHIMOURA Kansai Electric Power Co., Japan ECOC2001 ( Oct. 4, 2001 RAI Congress Centre,](https://reader036.fdocuments.in/reader036/viewer/2022062422/56649eb25503460f94bb9b13/html5/thumbnails/5.jpg)
Personal NSE Simulation SystemPersonal NSE Simulation System
![Page 6: Open-source NSE Codes Applied to 40 Gbit/s Soliton Lines KAZUHIRO SHIMOURA Kansai Electric Power Co., Japan ECOC2001 ( Oct. 4, 2001 RAI Congress Centre,](https://reader036.fdocuments.in/reader036/viewer/2022062422/56649eb25503460f94bb9b13/html5/thumbnails/6.jpg)
Simulation Reference SystemSimulation Reference System
![Page 7: Open-source NSE Codes Applied to 40 Gbit/s Soliton Lines KAZUHIRO SHIMOURA Kansai Electric Power Co., Japan ECOC2001 ( Oct. 4, 2001 RAI Congress Centre,](https://reader036.fdocuments.in/reader036/viewer/2022062422/56649eb25503460f94bb9b13/html5/thumbnails/7.jpg)
Q-factor definition for RZ-pulseQ-factor definition for RZ-pulse
![Page 8: Open-source NSE Codes Applied to 40 Gbit/s Soliton Lines KAZUHIRO SHIMOURA Kansai Electric Power Co., Japan ECOC2001 ( Oct. 4, 2001 RAI Congress Centre,](https://reader036.fdocuments.in/reader036/viewer/2022062422/56649eb25503460f94bb9b13/html5/thumbnails/8.jpg)
Dispersion map of the simulation modelDispersion map of the simulation model (Periodical dispersion compensation scheme)
![Page 9: Open-source NSE Codes Applied to 40 Gbit/s Soliton Lines KAZUHIRO SHIMOURA Kansai Electric Power Co., Japan ECOC2001 ( Oct. 4, 2001 RAI Congress Centre,](https://reader036.fdocuments.in/reader036/viewer/2022062422/56649eb25503460f94bb9b13/html5/thumbnails/9.jpg)
Pulse widths vibration in the DM-linesPulse widths vibration in the DM-lines ( 40Gbit/s, Dc=±20ps/nm, Lc=100km, with 6nm filters )
Global Structure Local Structure
![Page 10: Open-source NSE Codes Applied to 40 Gbit/s Soliton Lines KAZUHIRO SHIMOURA Kansai Electric Power Co., Japan ECOC2001 ( Oct. 4, 2001 RAI Congress Centre,](https://reader036.fdocuments.in/reader036/viewer/2022062422/56649eb25503460f94bb9b13/html5/thumbnails/10.jpg)
Q-maps for the 40 Gbit/s DM-Soliton Lines
(Nc = 2, Pav=+5dBm, La = 50 km, Lt = 3 Mm)
Optimal Dispersion Compensation: Dc = ±30 ps/nm
Dav – Dc plane Dav – Pav plane
![Page 11: Open-source NSE Codes Applied to 40 Gbit/s Soliton Lines KAZUHIRO SHIMOURA Kansai Electric Power Co., Japan ECOC2001 ( Oct. 4, 2001 RAI Congress Centre,](https://reader036.fdocuments.in/reader036/viewer/2022062422/56649eb25503460f94bb9b13/html5/thumbnails/11.jpg)
Nc = 4 Nc = 6
Q-maps for the 40 Gbit/s DM-Soliton Lines
(Nc = 4/6, Pav=+5dBm, La = 50 km, Lt = 3 Mm)
Optimal Dispersion Compensation: Dc = ±30 ps/nm
![Page 12: Open-source NSE Codes Applied to 40 Gbit/s Soliton Lines KAZUHIRO SHIMOURA Kansai Electric Power Co., Japan ECOC2001 ( Oct. 4, 2001 RAI Congress Centre,](https://reader036.fdocuments.in/reader036/viewer/2022062422/56649eb25503460f94bb9b13/html5/thumbnails/12.jpg)
La=30km La=80km
Q-maps for the 40 Gbit/s DM-Soliton Lines
(Nc = 2, Pav=+5dBm, La = 30/80 km, Lt = 3 Mm)
![Page 13: Open-source NSE Codes Applied to 40 Gbit/s Soliton Lines KAZUHIRO SHIMOURA Kansai Electric Power Co., Japan ECOC2001 ( Oct. 4, 2001 RAI Congress Centre,](https://reader036.fdocuments.in/reader036/viewer/2022062422/56649eb25503460f94bb9b13/html5/thumbnails/13.jpg)
La=30km La=80km
Q-maps for the 40 Gbit/s DM-Soliton Lines
(Nc = 2, Pav=+5dBm, La = 30/80 km, Lt = 3 Mm)
![Page 14: Open-source NSE Codes Applied to 40 Gbit/s Soliton Lines KAZUHIRO SHIMOURA Kansai Electric Power Co., Japan ECOC2001 ( Oct. 4, 2001 RAI Congress Centre,](https://reader036.fdocuments.in/reader036/viewer/2022062422/56649eb25503460f94bb9b13/html5/thumbnails/14.jpg)
PMD = 0.1 ps/km0.5
PMD suppression effect of soliton
(Nc = 2, Pav=+5dBm, Dc=+30ps/nm, La = 50km, Lt = 3Mm)
PMD = 0 ps/km0.5
![Page 15: Open-source NSE Codes Applied to 40 Gbit/s Soliton Lines KAZUHIRO SHIMOURA Kansai Electric Power Co., Japan ECOC2001 ( Oct. 4, 2001 RAI Congress Centre,](https://reader036.fdocuments.in/reader036/viewer/2022062422/56649eb25503460f94bb9b13/html5/thumbnails/15.jpg)
Optimal S-parameter for the DM-lineOptimal S-parameter for the DM-line( T. Yu, et. al., 1997 )( T. Yu, et. al., 1997 )
22
2211 55.2SS T
Dc
t
zkzkS
k = − ( λ2 / 2πc ) d = 1.27 D (ps/nm/km)
Ts (ps) : FWHM at chirp-free point
Dc = ±30 ps/nm, Ts = 6.8 ps S = 1.65
S = 1.65 ( T. Yu, et. al., 1997 )
![Page 16: Open-source NSE Codes Applied to 40 Gbit/s Soliton Lines KAZUHIRO SHIMOURA Kansai Electric Power Co., Japan ECOC2001 ( Oct. 4, 2001 RAI Congress Centre,](https://reader036.fdocuments.in/reader036/viewer/2022062422/56649eb25503460f94bb9b13/html5/thumbnails/16.jpg)
Results of the 40Gbit/s simulationResults of the 40Gbit/s simulation
Dispersion management strengthDc = ±30 ±10 (ps/nm)
: for all cases S = 1.65
Signal Power and Dispersion Dav = +0.04 ± 0.02 (ps/nm/km)
Pav = +7 ± 2 (dBm) : for La = 50km case
![Page 17: Open-source NSE Codes Applied to 40 Gbit/s Soliton Lines KAZUHIRO SHIMOURA Kansai Electric Power Co., Japan ECOC2001 ( Oct. 4, 2001 RAI Congress Centre,](https://reader036.fdocuments.in/reader036/viewer/2022062422/56649eb25503460f94bb9b13/html5/thumbnails/17.jpg)
Experimental setup of the 80 Gbit/s, Experimental setup of the 80 Gbit/s, 800 km transmission800 km transmission
MLLD LN
→10 40GMUX
10G(215-1)
Delay
PBSCoupler
80G
DSF
DCF
EDFA14APC
PBS
80G
PD
40G
40G PLL
EA1 EA2
20G 10G
80G 10G
10GReceiver
EDFA2
SPAN 1
EDFA1
SPAN 2
EDFA3
SPAN12
EDFA13
DSF
NZ-DSF
DCF
10G
![Page 18: Open-source NSE Codes Applied to 40 Gbit/s Soliton Lines KAZUHIRO SHIMOURA Kansai Electric Power Co., Japan ECOC2001 ( Oct. 4, 2001 RAI Congress Centre,](https://reader036.fdocuments.in/reader036/viewer/2022062422/56649eb25503460f94bb9b13/html5/thumbnails/18.jpg)
Bit Error Rate for 8*10Gbit/s CHBit Error Rate for 8*10Gbit/s CH
–19 –18 –17 –16 –15
Received Power (dBm)
Bit E
rror
Rate
10–11
10–10
10–9
10–8
10–7
10–6
10–5
● : CH1■: CH2▲ : CH3▼ : CH4○ : CH5□: CH6△ : CH7▽ : CH8
![Page 19: Open-source NSE Codes Applied to 40 Gbit/s Soliton Lines KAZUHIRO SHIMOURA Kansai Electric Power Co., Japan ECOC2001 ( Oct. 4, 2001 RAI Congress Centre,](https://reader036.fdocuments.in/reader036/viewer/2022062422/56649eb25503460f94bb9b13/html5/thumbnails/19.jpg)
Merit of the soliton-based systemMerit of the soliton-based system
For Long distance transmission
(Soliton stability effect, High intensity signal and suppressing PMD effect)
Conventional DSF without any dispersion slope compensation (Single Wavelength)
Narrow band low cost amplifier with Band pass filter is available.
Dispersion design is simple (Dc= ±30ps/nm)
Low cost High capacity system is possible.
![Page 20: Open-source NSE Codes Applied to 40 Gbit/s Soliton Lines KAZUHIRO SHIMOURA Kansai Electric Power Co., Japan ECOC2001 ( Oct. 4, 2001 RAI Congress Centre,](https://reader036.fdocuments.in/reader036/viewer/2022062422/56649eb25503460f94bb9b13/html5/thumbnails/20.jpg)
You can download some codeYou can download some code
http://www.asahi-net.or.jp/~ix6k-smur/soliton.htmlhttp://www.asahi-net.or.jp/~ix6k-smur/soliton.html