Original Operating Manual Operating manual OilControl air Art. No.: 030 480 030

Transcript of OilControl air EN - TECALEMIThorn-teca.de/oilcontrol-air/OilControlAir EN.pdf · be reached at all...

Original Operating Manual

Operating manual

OilControl air

Art. No.: 030 480 030

2 OilControl air

Copyright

It is essential that you read this manual thoroughly before installing and using this

software. Warranty claims for malfunctions and damage resulting from insufficient

knowledge of the content of this manual will be deemed null and void.

© HORN GmbH & Co. KG. All rights reserved.

The text, images and layout of this publication are protected by copyright law.

Reproductions and copies, including reproductions and copies of parts of this

publication, are permitted only with express written consent. Subject to technical

changes.

Service hotline +49 1805 900 301

Repair service +49 1805 900 302

(€0.14/min: when calling from a German land line, max. €0.42/min when calling from a

mobile phone)

[email protected]

Document No.:

Updated on: 10/2017

OilControl air 3

Contents

1 Safety instructions .............................................................................................. 5

2 OilControl air - Description ............................................................................... 6

3 Installation ............................................................................................................ 7

3.1 Web server ................................................................................................................ 7

3.2 “OilControl Air” server program ......................................................................... 8

3.3 Clients „OilControl Air“ ........................................................................................... 8

4 First Starting the Program Server ................................................................... 9

5 First Starting the Program Client ................................................................... 11

6 Login .................................................................................................................... 12

7 Orders .................................................................................................................. 13

7.1 Dispensation ........................................................................................................... 14

7.2 Creation .................................................................................................................... 17

7.3 Editing ...................................................................................................................... 17

8 Dispensation data ............................................................................................. 18

9 Display................................................................................................................. 19

9.1 Display ..................................................................................................................... 20

9.2 Tank fill level.......................................................................................................... 20

9.3 Configuration ......................................................................................................... 21

10 Master data ........................................................................................................ 21

10.1 Products ................................................................................................................... 22

10.2 Mechanic .................................................................................................................. 22

10.3 Units .......................................................................................................................... 22

10.4 Language.................................................................................................................. 23

10.5 EDP ............................................................................................................................ 25

10.6 User administration ............................................................................................. 33

11 Device configuration ........................................................................................ 34

11.1 Devices ..................................................................................................................... 34

11.2 WIFI/LAN ................................................................................................................. 37

12 Database ............................................................................................................. 38

13 Import protocols ................................................................................................ 39

13.1 Import protocol - File, Automaster, Visma ................................................... 39

13.2 Import protocol - Visma, only order numbers ............................................ 40

13.3 Import protocol – Autoline CN .......................................................................... 41

13.4 Import protocol – Autoline XML ...................................................................... 43

14 Export protocol.................................................................................................. 44

14.1 Data export protocol - File ................................................................................ 44

14.2 Data export protocol – Automaster ................................................................ 45

14.3 Data export protocol – Autoline CN ................................................................ 46

14.4 Data export protocol – Visma ........................................................................... 48

14.5 Data export protocol – Autoline XML ............................................................ 49

14.6 Export files ............................................................................................................. 50

15 Other .................................................................................................................... 51

16 Dispensation quality ......................................................................................... 51

10.5.1 Protocol 25

10.5.2 Data export settings 27

10.5.3 Registration in use protocol 30

10.5.4 Activating simple order creation 32

11.1.1 Pumping station 35

11.1.2 Tank 36

4 OilControl air

17 Troubleshooting ................................................................................................ 52

17.1 Client cannot connect to the server ............................................................... 52

17.2 Server Offline ......................................................................................................... 52

18 WEB Interface .................................................................................................... 54

18.1 Login ......................................................................................................................... 54

18.2 Orders ....................................................................................................................... 55

18.3 Dispensations ......................................................................................................... 58

18.4 Active ........................................................................................................................ 58

18.5 Product ..................................................................................................................... 58

18.6 Creation .................................................................................................................... 59

18.7 View .......................................................................................................................... 60

18.8 Tank ........................................................................................................................... 61

18.9 Devices ..................................................................................................................... 61

18.10Password ................................................................................................................ 62

17.2.1 Status Bar Messages 53

OilControl air 5

1 Safety instructions

This software has been programmed according to the very latest technical standards

and to recognized safety and technical regulations. Nevertheless, improper use could

result in loss of data. Therefore, it is essential that you follow the instructions

provided in this manual, in particular the safety instructions and the sections marked

with warning symbols.

Warning notices and symbols

The following symbols are used for especially important points in this operating

manual.

Please note

Specific details and/or instructions for damage prevention

Warning

Organizational Measures

This operating manual is to be kept within easy reach at the place of operation! Each

and every person involved in the installation and use of this software must have read

and understood the entire operating manual.

Qualified personnel

All persons who install and use this software must possess the necessary

qualifications for these tasks. The scope of responsibility, scope of competence and

monitoring of personnel must be precisely regulated by the operator. Any personnel

not possessing the required knowledge are to be trained and instructed accordingly.

In addition, the operator is to ensure that all personnel fully understand the content

of this operating manual.

6 OilControl air

2 OilControl air - Description

The Oil Control air program serves to facilitate communication between the present

TMS air/LevelController air units and the intranet. With the program, dispensing

orders can be set up, order information administer, and completed release

information saved as well was exported from the program.

The required login credentials are shown for each menu item. The server

administrator does not appear in this list as it has access to all areas.

The program version is displayed on the startup screen under the “TECALEMIT”

company logo, as well as in the program title bar.

The help file shown here can be opened via the highlighted button. The link found

there opens the program page online. Here you can learn about program updates at

regular intervals.

OilControl air 7

3 Installation

Minimum system requirements

Runs on Windows 7 or newer.

Processor (CPU)

• Intel Pentium® IV 2.0 GHz

• AMD Athlon® XP 2000+

Memory (RAM)

• 2 GB

Resolution (monitor):

• 1024x768

Communication from “TMS air” as well as “LevelController air” units takes place over

the local intranet. The devices communicate via the UPD and TCP/IP protocol. When

shipped, the default port for data transfer is pre-set to 64937.

Thus, for operation the server PC must be permanently reachable on the intranet for

the units present. The web server as well as the database must run set up as a service

on this server PC, along with the “OilControl air” program installed and running

constantly.

3.1 Web server

The web server must always receive a fixed assigned IP address at which it can

be reached at all times on the intranet.

The complete “XAMPP” index from the installation CD should be copied to the server

PC on the intranet. C:\ is the recommended path for the directory. After copying the

web server then has the directory: C:\XAMPP\

The file “setup_xampp.bat” is located in this directory.

This should be run once by right-clicking on the file and by selecting “Open.” The

following directions are to be followed as the web server is configured in the

installation directory.

Later on in the description it’s assumed that the web server is located in the

“C:\xampp\” directory for the configuration. If another directory was chosen, then the

next steps should be run accordingly.

Firewall

When setting up the following two services a firewall message can occur. Access

to the domain network must be granted to each service. Without access, no data

connection to the units can be made. Additional information available at:

Troubleshooting, Chapter 17

Configuring the firewall

8 OilControl air

The file “xampp-control.exe” is located in the “xampp” directory. It can be started

“Run as administrator” by right-clicking on the file. Start the Apache or MySQL

module under “Actions” and grant access to the domain network for each firewall

notification. After starting each module, then stop it again and close the “XAMPP

Control Panel” via the “Exit” button. The services are then installed.

Apache service

In order to install the Apache web server as a service, the file

“apache_installservice.bat” in the “C:\xampp\apache\” directory must be opened by

right-clicking with the mouse on the file “Run as administrator.” The service should

then be successfully installed.

MySQL Service

The MySql database should also be configured on the Apache Server. To do this, the

file “mysql_installservice.bat” in the “C:\xampp\mysql” directory must be opened by

right-clicking with the mouse on the file “Run as administrator.” The service should

then likewise be successfully installed.

In the Windows system control under services, both services should now be in the list

(Apache 2.4 as well as MySQL).

3.2 “OilControl Air” server program

After the Apache web server and the MySQL database are set up as services and are

running, the program “OilControlAir-Setup” can be run from the installation CD.

Follow the on-screen instructions during installation. After the first start of the

program the connection to the database then has to be correspondingly configured.

The program “OilControl air” must permanently run on the computer running the web

server. The program is necessary for the connection of “TMS air” as well as the

“LevelController air-” units to the server.

3.3 Clients „OilControl Air“

As soon as the “OilControl air” program is running as a server on the server PC,

additional client installations can take place on the intranet. Once again the

“OilControlAir-Setup” program from the installation CD should be used on each

computer. The connection to the server via the IP address of the server PC should be

set up correspondingly for the clients.

OilControl air 9

4 First Starting the Program Server

Requirement: Apache Server and MySQL database running on the same PC as a

service.

At the first starting of the program of the OilControl air software on the PC, which is

acting as a server, only the database button is activated. The program default setting

must first be made here.

After clicking the "Database" button, the following view opens. Enter the IP address of

the server PC running this software "OilControl air."

If you don't know the IP, simply press the “My IP Address” button. The command

“ipconfig” is now carried out in the DOS prompt. The IP address shown under “IPv4

Address” in the Ethernet adapter LAN is to be entered as shown into the “IP Address”

field. In the following example: 192.168.109.217

10 OilControl air

After entering the IP address, press the “Connect” button. A connection to the MySQL

database is created.

Upon successful connection to the server the window, as can be seen in the display, is

expanded. Without a connection, the entered IP address must first be checked. If this

doesn't work, then switch to the chapter 17“Causes of error.”

The port for communicating with the devices can be changed on the server. The

factory default is set to 64937. A change might be necessary if this port is already in

use by other devices on a network, or if this port or port area is locked by the system

administrator.

At the bottom right of the start screen, the URL on which the web interface is to be

accessed is displayed on the server. The standard browser opens the corresponding

site with a mouse click on the URL. The displayed barcode can be scanned with a

smartphone or tablet. If the device is located on the same network (intranet) as the

server, the corresponding URL can also be opened on the respective device.

OilControl air 11

On the start screen, the program version with the corresponding additional

server/client is displayed under the company logo, here "(server).”

5 First Starting the Program Client

If the program is not installed on the server but on another computer on the intranet,

it is automatically a client installation.

At the first starting of the program of the client, only the database button is

activated.

Press the "Database" button to open the following view. Enter the IP address of the

server PC. This IP address can be read in the status line of the server installation

"OilControl air".

12 OilControl air

If the connection to the server is successful, the program is displayed as a client

version under the company logo:

If no connection is established, a fault message is output. Additional information

available in Chapter 17: “Troubleshooting.”

6 Login

There are four different access permissions for access to "OilControl air." In

descending order, these are:

• Server administrator

• Installer

• Administrator

OilControl air 13

• User

Only the server administrator has all permissions on the server. If the server

administrator logs on to a client, the menu item becomes "Database is hidden".

Database settings can only be made on the server itself.

In the delivery state, the password and access rights are identical, but however are

written lowercase (see Chapter 10.6).

The installer has the same permissions as an administrator. In addition, he can

configure the devices on the network from each client.

The administrator can execute basic functions. This includes, among other things, the

creation of orders or the assignment of codes to technicians. For details, see the

specific menu item in this help.

The user can carry out dispensations and inspect the completed dispensations. He has

the possibility to display a monitor window for an overview.

7 Orders

Orders can be manually set up in the “Set up” menu rider (Chapter: 7.2). It’s also

possible to import orders from a Dealer Management System (DMS)10.5.310.5.3). All

open orders in the program are displayed in this form for selection in table form.

If only the value of the dispensation data is set, the "simplified order creation" can be

activated for dispensation (Chapter 10.5.4).

14 OilControl air

7.1 Dispensation

Permission level: User, Administrator, Installer

By selecting an order in the table, the order number and position are displayed. The

product name and quality are displayed for this order. If an order as a preselection

quantity is 0.00 liters, this means that this order number may be issued indefinitely.

The actual dispensation quantity is displayed summed up accordingly after a

dispensation. In the "Edit" menu bar the unlimited dispensation can be manually

canceled later.

To start a dispensation, the operator must enter his/her code (see Chapter: 10.2). The

dispensing unit as well as the pumping station are to be selected and the desired

dispensing quantity has to be entered.

If simple order generation is activated, a complete order with order number and

position can simply be created and issued immediately. If an order list is also being

worked with at the same time, the order is selected from the order list if the entry is

correct. In this case, the quantities and the quality of the already existing order are

taken into account when starting.

OilControl air 15

If 0.00 is permitted as a preselection quantity (Chapter 10.5.1), an order can be

started by entering 0.00 liters. The maximum dispensing quantity of the dispensing

point is set as the preselection quantity (Chapter 11.1.1). If the maximum preselection

quantity is not fully output, the remaining quantity (difference between preselection

quantity and dispensing quantity) is still available as an order. An additional

dispensation could be made on this order.

If the entry of 0.00 liters is not permitted as a preselection quantity, a job can only be

started if a preselection quantity has been entered.

By pressing the "Start dispensation" button, the desired dispensation is saved in the

server database. The server now sends the release to the selected TMS air

dispensation device.

As soon as a dispensation is started, an additional dispensing window appears. The

status as well as the dispensation quantity are displayed running up to date in this. A

current dispensation can be canceled at any time via the “Cancel” button.

The dispensing window automatically closes 2 minutes after the end of the

dispensation.

If a dispensing quantity is entered which is higher than the pre-selection quantity,

then a notification is issued that this quantity cannot be dispensed.

The available dispensing quantity is calculated from the preselection quantity of the

job minus the quantity already dispensed to this job.

16 OilControl air

The conformity of permissible product quality in the job and product quality at the

selected pumping station is examined. If these do not match, then the dispensation

cannot be started. The button for starting dispensation is deactivated.

The qualities of the pumping stations are set by the server administrator or the

installer (Chapter 10.6) in the device configuration (Chapter 11.1.1).

If a job has the quality of 0, a dispensation can take place to any pumping station. Job

quality 10 can only dispensed at pumping stations that have the quality 11, 19, etc. A

job with quality 11 can only be dispensed at a pumping station that also has quality

11, etc.

As soon as a dispensation to a job with quality 0 or 10 takes place, the quality in the

job is replaced with that of the pumping station. Further dispensing on this order is

only possible with an exactly matching quality of the pumping station.

A dispensation is declined for an incorrectly set quality.

The display of the order data can be limited to a freely selectable period.

OilControl air 17

While entering an order number into the search field, the data is already filtered

accordingly. A search can be easily reset using the displayed button, then all job data

for the selected period will be displayed again.

7.2 Creation

Permission level: Administrator, Installer

Order data can be manually created here. A unique combination of order number and

item is required for creation. Additionally, pre-selection quantity as well as the

quality of the job can be set.

After saving, the order is displayed in the table and can be selected for dispensation.

7.3 Editing

Permission level: Administrator, Installer

After selecting an order in the table, it can be edited. Every entry can be changed

after the fact. When saving, a new time stamp is added to the edited order.

18 OilControl air

Orders that have not yet been dispensed can be removed from the system using the

"Delete" button. It is also possible to delete all orders for which no dispensation was

made at once.

Before the final deletion, a security query must first be confirmed.

The order status can also be changed here. If an order is switched from “canceled” to

“complete,” it is then removed from this display. An additional dispensation on this

order number/item is thus no longer possible. Completed orders are located in the

“Dispensation data” menu item (Chapter 8).

For a button to manually set the status, the order must be backed up for at least 2

minutes without changes to the database.

8 Dispensation data

Permission level: User, Administrator, Installer

Each order for which a dispensation has already been made is located in the

dispensation data. The data can be filtered by status as well as time frame. If no

status is selected, then all the data sets are displayed. It is likewise possible to search

for an order in the selected time frame.

The data displayed can be read out as a report as well as exported. The data export

can take place with column headings. The separator symbol for the data export can

be chosen from the list.

OilControl air 19

All dispensations as well as partial dispensations of the orders are shown in the table.

Product name, TMS air, and user name can be set in the OilControl air program.

The preselection quantity is the quantity that can be given for the order with this

item. The dispensation quantity is the actual quantity that was dispensed on this

order.

Permission level: Administrator, Installer

With the appropriate authorization, jobs in the system can be set to the status

“deleted.” It’s possible to set an individual order or all displayed orders at once to the

status “deleted.”

If, under the selection window for the time period, a check mark is placed on “Display

deleted,” individual records or all those that have the status "deleted" can be set to

the status “existing” again.

9 Display

The selected display can show up to four pumping stations or tanks at the same time.

The display window is always in the foreground. If several displays were stored in

the program, you can switch between them via the selection field.

20 OilControl air

9.1 Display

Permission level: User, Administrator, Installer

The current or the most recently executed dispensation is displayed for a pumping

station. The display is made using the name stored in the program. Additionally, the

dispenser point, product, order number, as well as the order status are shown. In the

event of a dispensation, the ongoing update of the display takes place with the

current dispensation quantity.

The current fill level, product name, as well as the date and time of the last measuring

are shown for a tank. When signing in as installer or server administrator, the output

of the fill level also takes place in mm underneath the fill level display.

9.2 Tank fill level

Permission level: User, Administrator, Installer

All LevelController air are displayed in table form with their tanks.

By selecting a tank, the current values of this tank are displayed below in the table.

Only the last value of the day is saved for each tank.

OilControl air 21

9.3 Configuration

Permission level: Administrator, Installer

Only the description should be entered to create and save a view. Four freely

selectable units with the corresponding pumping stations or tanks can now be

assigned to this. The sequence can be changed by the displayed arrow keys within

the view. The removal of units is also possible via the corresponding button.

10 Master data

Administrators and installers have access to the products and mechanics in the

master data. They only have access to orders if the program OilControl air has not

been registered. The settings for the orders are assigned to the “Log” menu item upon

registration.

Any other settings can only be handled from the server administrator on the server

PC.

22 OilControl air

10.1 Products

Permission level: Administrator, Installer

The names of the product groups can be changed in this view. In addition to the

product name, the individual qualities can also include item number and cost center.

Item number and cost center for example can be required for the dispensation data

export according to the selected log.

A quality can only be deleted if it is no longer assigned to a pumping station.

Qualities can be assigned to pumping stations in device configuration (see Chapter

11.1.1)

10.2 Mechanic

Permission level: Administrator, Installer

To start a dispensation, the mechanic must first enter his/her code. The mechanic can

be set up with a code and name on this screen. It’s possible to block a created

mechanic so that it can no longer start a dispensation.

10.3 Units

Permission level: only server administrator

The display unit, the number of decimals, as well as the displayed measuring unit can

only be set up or changed by the server administrator on the server PC. These

settings however are valid for all users.

OilControl air 23

10.4 Language

Permission level: only server administrator

The display at runtime can be changed via the language selection.

A new language can simply be added to the system. After entering the language

abbreviation (ISO 639-1), the “Save” button is activated. When saving the language,

this is set by default to English terms, which can be translated later.

If the language abbreviation of an existing language - except for DE and EN - is

entered, it can be deleted after confirming a security question.

One language - except for DE and EN - can be freely translated. The individual entries

are displayed in the “Personal translation” text field. The change is made after saving.

If the checkmark “Show the next record automatically” is set, the next record is

automatically written for translation into the field after saving.

You can also choose whether the original term should be displayed in DE and/or EN

for the translation.

24 OilControl air

A language can be saved as a CSV file with the selected delimiter (semicolon or

comma) via the “Export” function. The file build then looks like as shown in the

screenshot.

In the first line, the heading with the number and the exported languages is separated

by the set separator, here a semicolon.

Number;EN;PO;

1004;Abort;Abort;

The last entry between the semicolons would have to be correspondingly translated

for PO (Polish). The rest, including the semicolons, have to be kept in the file.

When translating, the “###” can be seen as a placeholder. It must be correspondingly

placed in the translation. Symbols in tags like <br> for line break or <b> for bold are

to be left unchanged in the text.

OilControl air 25

After compilation and saving, this file can be read again by the program via the

Import button. The language is then correspondingly updated (except for DE and EN).

10.5 EDP

Permission level: only server administrator

If order data is to be read in automatically, this is done via a defined protocol. The

software must be correspondingly registered before for the selection of the protocol

(Chapter: 10.5.3).

10.5.1 Protocol

There are currently the following protocols for data import: “File,” “Automaster,”

“Autoline CN,” “Visma,” as well as “Autoline XML.” The file build of these protocols is

described in the Chapter 13 “Import Protocols.”

A corresponding directory for data exchange must be selected for data import. The

Dealer Management System (DMS) saves the import files with the order data in this

directory.

If the protocol works with a code number for workshop identification, only order data

with the stored code number and the default code 0000 are read in.

The designation of the order import file must always be the same. The program

imports the order data from the file and then deletes them.

If dispensation data have to be saved after a dispensation in the selected directory,

then data export should be activated. By default, the data is saved in the file format.

To select a different format, or create a custom format, use the Export button to open

a corresponding export mask (see Chapter 10.5.2).

Querying mechanic code

If this option is activated, then the mechanic has to enter his code prior to

dispensation. After dispensing, the dispensation is then saved to the order with the

name of the mechanic (Chapter 10.2).

26 OilControl air

Querying preselection quantity

If this option is activated, then the desired dispensation quantity (preselection

quantity) must be entered before dispensation.

Allowing preselection quantity 0.00

If 0.00 liters is permitted as a preselection quantity, the maximum dispensation

quantity or the tap point limit is sent as the dispensation quantity to the dispenser as

the desired dispensation quantity and released. In the software’s default factory

settings this option is deactivated.

ASA

On an ASA network the order data is made available via the ASA network manager

from the DMS. Dispensation queries as well as dispensation data transmission both

take place via the intranet.

OliePcV4

URL, valid apiKey, as well as dealerId must be entered. After saving, an attempt is

made to retrieve existing job data via the interface (URL). The interval, in which the

complete order data is called up and updated, can be configured from “15 min.” all the

way to “24 hours.”

A URL query is carried out before every dispensation, to find out whether the order

number permits a dispensation. Completed dispensation data is transmitted to the set

URL.

DRACAR+

URL, username and password must be entered. After saving, the job data is checked

via the network. If the check is positive, a release is carried out. Submission data is

transferred back to the DMS in the intranet.

If the selection field “Transmit <MecahnicNo>” is set, the number of the

operator on the delivery unit is transmitted to the DRACAR+ DMS. If this

operator is not known in the DRACAR+ system, the order data cannot be stored in

the system.

OilControl air 27

Simplified order creation is not possible with the “ASA” protocol.

Data export

Supported data export protocols are described in Chapter 14.

Simplified order creation as well as blocking all dispensations is described in Chapter

10.5.4.

10.5.2 Data export settings

The data export protocols: “File,” “Automaster,” “Autoline CN,” “Visma,” and “Autoline

XML” are available. Each export protocol can be modified for individual needs.

28 OilControl air

Click the “New” button to set up a new data export protocol. The name for the export

protocol must first be saved. The export file name with file extension (e.g. export.txt)

must be entered next.

The individual fields that are ready for data export can now be selected from the list

and added in the appropriate order.

OilControl air 29

You can subsequently change the order by using the arrow keys. A field can then

later be taken out of the export list via the “Delete” button.

General:

Empty spaces are entered by the symbol °. During actual data export, the ° characters

are replaced by the corresponding number of spaces.

If a field has a line break, this can be handled by entering #13#10. During the data

export, this string is replaced by the line break.

You can set properties for each field in the list:

Field length: If the field is supposed to have a fixed length, the corresponding value

can be entered here. If the entry is shorter, this is filled with the set fill character. If

the field is longer than the set field length, the last characters are ignored.

Prefix: You can enter what should be before the output of the field.

Suffix: You can enter what should be after the output of the field.

Format: If the number field is selected, this number can be output formatted. It is

possible to output a number with more than one decimal place. The corresponding

formatting is to be entered here, e.g. 0.000 for 3 decimal places. If the number isn't

supposed to have any decimal places, just enter a 0 here.

The output can be made at the date/time. The values for the day are output with dd,

for the month mm, and yyyy for the year. For the time hh stands for hour, nn for

minute, and ss for second.

The dispensation time field appears twice. Thus, for example, it is possible to output

the date in the format dd.mm.yyyy and later the time in the format hh:nn.

If an existing format in a field should be deleted, the entry field “Format” should be

cleared.

If the field Dispensation unit is ticked, the unit is converted according to the selected

dispensation unit.

30 OilControl air

A different formatting can be set for each field. The fill character and the fill

orientation can be changed.

The standard file export name is located in general settings. A header can be set for a

file. This is written first when the file is created. The footer is written after inserting

the data to be exported.

The values at which the “Dispensation unit” field has been ticked are converted to the

set dispensation unit.

The decimal separator can be set freely for the conversion.

If a field length is specified for data records, they are filled with the fill character.

Only the actual field content, subsequently the set fill characters.

If the check mark is set to "Last line without line break", no further line break occurs

after writing the dispensation data record.

10.5.3 Registration in use protocol

If the “OilControl air” program is supposed to be used together with a DMS protocol,

the program should be activated first.

Program registration can take place online, by telephone, or via email.

Online activation

A working internet connection is required for online activation. In order to activate

the software, you will need to enter the product code and the name of your company.

After clicking on “Activate online,” an activation code is retrieved from the internet

and then the software is immediately released and executable.

The software can only be re-registered with the same product code if it is reinstalled

on the same partition of the same computer.

OilControl air 31

In the case of an online activation, it is possible to enter the data for an existing

proxy server. By activating the proxy setting, the online registration is performed via

the proxy server.

Activation by email

To activate your software via email, the product code and company name are

required. By clicking on the “Activate by email” button, the following email (see

screenshot) appears and is already populated with information for you to complete

and send. Your activation code will be promptly emailed to the address that you used

to request it. This will be no later than on the following working day.

Note: Check your spam/junk filter, if you have one.

32 OilControl air

Telephone Activation

You can also activate your software by telephone, using the service hotline number

shown. Make sure you have your product code ready for this.

After successful activation, a corresponding message window is displayed and the

display for the protocol selection appears after confirmation.

10.5.4 Activating simple order creation

Permission level: Administrator, Installer

In the basic version without registration, these settings are located in the “Order”

menu. If the registration is successful, the settings under the protocol selection are

displayed in the menu “EDP,” see Chapter 10.5.1.

If simple order creation is activated, a new order can be generated in the Orders

menu with immediate dispensation. If the entered order number is with the position

in the order list, it is marked and output accordingly.

All requested dispensations can be declined on the server PC in order to completely

block oil dispensation. The corresponding checkmark is to be placed on “Decline all

dispensations.” After placing the check mark, this is indicated in red.

OilControl air 33

This is displayed on the connected “OilControl air” clients by a blinking “LOCKED”

entry in the program status bar.

10.6 User administration

There are 4 different types of permissions:

• Server administrator

• Installer

• Administrator

• User

The username and password are identical and lowercase in the delivery state.

The server administrator has the most permissions and cannot be deleted. The server

administrator has to sign in on the server PC in order to execute the general settings

required for the system.

The server administrator can change his or her password on this screen, as well as

reset other users’ passwords, block them, or delete their access.

The server administrator can also add new users. To do so, just click on the "New"

button, assign a user name, and assign the new user the appropriate permission.

When logging in for the first time, the new user then has to set up their own

password.

34 OilControl air

All the created users are shown in the table. If a user logs on, the used "OilControl air"

software version is saved together with the date and time. The language selected by

the user as well as the “Blocked” status are visible. Permissions can be seen under

“Administrator.”

11 Device configuration

Permission level: Server administrator, Installer

TMS air and LevelController air, which are present in the network, continually

communicate on the network via the set UDP port. If the OilControl air server has

been restarted or a new device has been added to the network, the configuration is

automatically called up. New devices are added to the existing list of selections.

Each device has its own number. The displayed number can be replaced by a

corresponding name. The firmware version and IP address of the present devices are

listed here. When a device is selected, the related data is shown on the right side.

Click the “Delete” button to remove devices that are no longer needed from the

program.

11.1 Devices

The devices are divided into TMS air units each with up to 5 pumping stations, as well

as LevelController air units to which up to 5 tanks can be connected each.

OilControl air 35

11.1.1 Pumping station

Each pumping station can be individually configured with the “OilControl air”

program. The corresponding entry can be edited via the pumping station or by

selecting the pumping station via the displayed table.

The quality of the pumping station can be set according to the products (see Chapter

10.1). The correct quality is also necessary for the release of an order (see Chapter

7.1). The given product name for the quality is displayed under the selection field.

The type of pulse generator, the pulse value, the pulse correction factor, the pre-

switch-off value as well as the limits for the dispensation quantity, the dispensation

time, and dispensation pause can be set for each pumping station. Click “Save” button

to confirm the values.

The values of all 5 dispensing points are transferred together via the “Send” button to

TMS air. The button is first deactivated during the sending process.

If the data transfer was successful, the label “OK” is displayed shortly afterwards,

otherwise the notice “Failed” appears on the button.

The button is reactivated after the transfer.

36 OilControl air

If a pumping station is blocked, no dispensation can take place at this pumping station

under the menu item “Order.” The pumping station is displayed as blocked and the

button to start dispensation is deactivated.

In the delivery state of TMS air the pumping stations have the following qualities:

Pumping station 1 — Quality no. 11

Pumping station 2 — Quality no. 12

Pumping station 3 — Quality no. 13

Pumping station 4 — Quality no. 14

Pumping station 5 — Quality no. 15

LevelController air units with their available tanks can be assigned to individual TMS

air units. Before a dispensation a query of the tank fill level is first carried out. Only

with sufficient tank fill level quantity for the desired pre-selection quantity is the

release then sent to the pumping station.

11.1.2 Tank

The tanks connected to a LevelController air unit can be parameterized here with

their values. After saving, the values can be transferred to the device as with the TMS

air pumping station. The “Send” button then shows the corresponding status

information.

OilControl air 37

The product name is displayed when a tank has been assigned to a pumping station.

11.2 WIFI/LAN

In the delivery state, the software and units are also able to communicate on the

network without explicit configuration. If for example, the standard port 64937

cannot be used, or if devices are not supposed to communicate via LAN, but via WIFI,

or if fixed IP addresses are to be used in the network, the devices can be configured

here.

By saving the device-specific configuration on a USB flash drive, these can be

transferred to the device. To do this, simply insert the USB flash drive into the device

to be configured. After the read-in process has been completed, an acoustic output is

sent to the device.

38 OilControl air

12 Database

For data security, a daily backup of the database can be run. In the input field, enter

the path in which the backup is to be executed, or select the appropriate button. The

daily backup is activated by checking the box next to “every day in the month.”

The file name of the database backup is composed of the name as well as the current

calendar day in the month. An existing back up from e.g. the 15th of the month

(TMS_backup_15.sql) is overwritten in the following month on the 15th. Backups are

available for the last 30 days at most.

In the Support area, clicking on the relevant legend opens the corresponding directory

in Windows Explorer.

OilControl air 39

13 Import protocols

13.1 Import protocol - File, Automaster, Visma

Order data file (“ORDERS.TXT”)

If this file doesn’t exist, it is set up by the DMS, otherwise the datasets are added to

the existing file. Every order is saved in a cell and ended with CR/LF. Values are filled

out with leading zeros.

Item Length Format Description

1 2 nn

Order status

“01:” Create new order

“02:” Delete order number

“03:” Delete all prior existing orders (reset)

3 4 nnnn Code number

“0000:” no meaning

7 11 nnnnnnnnnnn Order number

18 4 nnnn Order sequence number

(=“0000”)

22 2 nn

Product selection

“00:” All products permitted

“10:” Motor oil group permitted

“20:” Transmission fluid group permitted

24 7 nnnnnnn Maximum dispensation quantity [ml]

“0000000:” No maximum

31 1 CR (0x0D) Carriage return

32 1 LF (0x0A) Line feed

The code number can be placed in the Administration menu item.

Product selection: Motor oil: “11” - “19,” transmission fluid: “21” - “29,” servo oil “31”

- “39,” brake fluid “41” - “49,” air conditioning: “51” – “59,” coolant: “61” – “69”

Example of an order line:

010000000001234560000130004500<CR><LF>

Description:

01: Create order

0000: no code number

00000123456: Order number 123456

0000: No sequence number

13: Motor oil quality no. 13

0004500: Maximum dispensation quantity 4,500 ml = 4.5 liters are permitted

40 OilControl air

13.2 Import protocol - Visma, only order numbers

Order data list (e.g. “ORDERS.TXT”)

If the order data list doesn't exist, it is set up by the Dealer Management System

(DMS). A new order list completely replaces an existing order list.

Each order number is stored in one line, the lines are completed by CR/LF.

Item Length Format Description

1 max. 11 nnnnnnnnnnn Order number

1 CR (0x0D) Carriage return

1 LF (0x0A) Line feed

Example of an order file:

12345678901<CR><LF>

20030401<CR><LF>

12345<CR><LF>

OilControl air 41

13.3 Import protocol – Autoline CN

Order data file (“ORDERS.TXT”)

If this file doesn’t exist, it is set up by the DMS, otherwise the datasets are added to

the existing file. Every order is saved in a cell and ended with CR/LF. Values are filled

out with leading zeros.

Item Lengt

h Format Description

1 2 nn

Order status

“01:” Create new order

“02:” Delete order number

“03:” Delete all prior existing orders (reset)

3 4 nnnn Code number

“0000:” no meaning

7 12 cccccccccccc Vehicle identifier

19 12 nnnnnnnnnnnn Order number with leading zeros.

31 4 nnnn Order sequence number

(=“0000”)

35 2 nn

Product selection

“00:” All products permitted

“10:” Motor oil group permitted

“20:” Transmission fluid group permitted

37 7 nnnnnnn Maximum dispensation quantity [ml]

“0000000:” No maximum

44 7 nnnnnnn

Previous dispensing quantity [mL] on this order with

this sequence number (permits dispensation in

several sequences)

51 1 CR (0x0D) Carriage return

52 1 LF (0x0A) Line feed

The code number can be placed in the Administration menu item.

Product selection: Motor oil: “11” - “19,” transmission fluid: “21” - “29,” servo oil “31”

- “39,” brake fluid “41” - “49,” air conditioning: “51” – “59,” coolant: “61” – “69”

Example of an order line:

01 0000 000000000000 000000123456 0000 13 0004500 0000000<CR><LF>

(empty spaces are added for legibility, they are not in the order)

42 OilControl air

Description:

01: Create order

0000: no code number

000000000000: No identifier

000000123456: Order number 123456

0000: No sequence number

13: Motor oil quality no. 13

0004500: Maximum dispensation quantity 4,500 ml = 4.5 liters are permitted

0000000: No previous dispensation = 4.5 liters are permitted

OilControl air 43

13.4 Import protocol – Autoline XML

Order data list (e.g. “ORDERS.TXT”)

If the order data list doesn't exist, it is set up by the DMS. A new order list completely

replaces an existing order list.

44 OilControl air

14 Export protocol

14.1 Data export protocol - File

Dispensation data (“TRANSACT.TXT”)

If this file doesn’t exist, it is set up by the “OilControl air” program, otherwise the

datasets are added to the existing file. Every dispensation is saved in one cell and

ended with CR/LF. Values are filled out with leading zeros.

Item Length Format Description

1 2 nn

Dispensation status

“01:” Dispensing completed OK

“02:” Dispensation ended with a minor error

“03:” Dispensation ended with a major error

3 4 nnnn Code number

7 11 nnnnnnnnnnn Order number

18 4 nnnn Order sequence number (=“0000”)

22 2 nn Product number

24 7 nnnnnnn Dispensation quantity [ml]

31 3 nnn Pumping station

34 3 nnn Operator number

37 6 nnnnnn Dispensation date (DDMMYY)

43 4 nnnn Dispensation time (HHMM), 24h format

47 12 cccccccccccc Additional information (=„ “)

59 1 CR Carriage return

60 1 LF Line feed

Example of a dispensation line:

0100780000012345600001300044500110971301041445 <CR><LF>

Description:

01: Dispensation ended OK

0078: Code number 78

00000123456: Order number 123456

0000: No sequence number

13: Motor oil quality no. 13

0004450: Dispensing quantity 4,450 ml = 4.45 liters

011: Pumping station 11

097: Operator 97

130104: Dispensation date 01.13.2004

1445: Dispensation time 2:45 p.m.

“ “: Additional Information

OilControl air 45

14.2 Data export protocol – Automaster

Item Length Description Example data

1 12 Fixed value FD1 +-------

13 14 Timestamp 07.14.05 4:12 p.m.

28 10 Dispensation quantity 8.410

39 6 Mechanic number 802

46 6 Order number 224869

87 12 Product name o145066

Example of a dispensation line:

FD1 +------- 07.14.05 4:12 p.m. 8.410 802 224869 0 0 0 DELVAC 5W30

O145066

46 OilControl air

14.3 Data export protocol – Autoline CN

Dispensation data (“TRANSACT.TXT”)

If this file doesn’t exist, it is set up by the “OilControl air” program, otherwise the

datasets are added to the existing file. Every dispensation is saved in one cell and

ended with CR/LF. Values are filled out with leading zeros.

Item Length Format Description

1 7 nnnnnnn Ongoing transaction number

8 2 nn

Dispensation status

“01:” Dispensing completed OK

“02:” Dispensation ended with a minor error

“03:” Dispensation ended with a major error

10 4 nnnn Code number

14 12 cccccccccccc Vehicle identifier

26 12 nnnnnnnnnnnn Order number

38 4 nnnn Order sequence number (=“0000”)

42 2 nn Product number

44 7 nnnnnnn Maximum dispensation quantity [ml]

51 7 nnnnnnn Added up dispensing quantity [mL] (prior & current

dispensation)

58 3 nnn Pumping station

61 3 nnn Operator number

64 6 nnnnnn Dispensation date (DDMMYY)

70 4 nnnn Dispensation time (HHMM), 24h format

74 12 cccccccccccc Additional information (=“ ”)

86 1 CR Carriage return

87 1 LF Line feed

Example of a dispensation line:

0000251 01 0078 000000000000 000000123456 0000 13 0004500 0004450 011

097 130104 1445 <CR><LF>

(empty spaces are added for legibility, they are not in the dispensation)

OilControl air 47

Description:

0000251: Transaction number 251

01: Dispensation ended OK

0078: Code number 78

000000000000: No identifier

000000123456: Order number 123456

0000: No sequence number

13: Motor oil quality no. 13

0004500: Maximum dispensation quantity 4,450 ml = 4.5 liters

0004450: Dispensing quantity 4,450 ml = 4.45 liters

011: Pumping station 11

097: Operator number 97

130104: Dispensation date 01.13.2004

1445: Dispensation time 2:45 p.m.

“ ”: Additional information

48 OilControl air

14.4 Data export protocol – Visma

Dispensation data (“ORDCHGR.edi”)

If this file doesn’t exist, it is set up by the “OilControl air” program, otherwise the

datasets are added to the existing file. Every dispensation is saved in one cell and

ended with CR/LF.

Field name Example Format Comments

Order head start H. Always = H

Order number 372 Integer Must exist in Visma

Transaction type 1 Integer Always = 1

Customer number Integer Optional

Order date Integer Optional Format yyyymmdd.

Mileage String Optional

Work order number 123 Integer Optional

Registration number String Optional

Project Integer Optional

Head status Optional

Order line start L Always = L

Order line number Integer Optional.

Product number 1001 String Must exist in Visma

Product description String Optional

Quantity 3.5 Float Decimal point = .

Memo file path String Optional

NetQty 1 Integer Always = 1

Employee no. 3 Integer Must exist in Visma

Line status 1 Always = 1

OilControl air 49

14.5 Data export protocol – Autoline XML

Dispensation data (“Result.xml”)

If this file doesn’t exist, it is set up by the “OilControl air” program.

50 OilControl air

14.6 Export files

The export files created by the individual protocols appear as follows:

File:

Automaster:

Autoline CN:

Visma:

Autoline XML:

OilControl air 51

15 Other

The display on the start page of the server software "OilControl air" is updated

continuously. A unit is displayed as “offline” if it has not reported in the last 5

minutes.

All open application windows can be closed at the same time by a right mouse click.

The right-click doesn’t work on the opened display window.

16 Dispensation quality

List of qualities (gen. usual convention)

----------------------------------------------------------------

000 Oil, grease, and fluids management

010 Motor oil, gen.

011 Motor oil type 1

012 Motor oil type 2

etc…

020 Transmission fluid, general (incl. rear axle)

021 Transmission fluid type 1 (incl. rear axle)

022 Transmission fluid type 2 (incl. rear axle)

025 Rear axle oil type 1 (only for rear axle)

026 Rear axle oil type 2 (only for rear axle)

etc…

030 Power steering fluid, general

031 Power steering fluid type 1

etc…

040 Brake fluid, gen.

etc…

050 Air conditioner coolant

etc…

060 Radiator fluid

etc…

070 Washing water

etc.

52 OilControl air

17 Troubleshooting

17.1 Client cannot connect to the server

• Is the server PC running?

• Is “OilControl air” software running on the server?

• Is the server reachable from the client? To test using the input prompt (cmd), send a

ping request to the server IP address (see the following screen).

Check the server's firewall settings to allow the Apache HTTP Server and mysqld

services to access the network.

If one of these services is missing, the "xampp-control.exe" can be started by right-

clicking "Run as administrator" in the "xampp" directory on the server. Start the

Apache or MySQL modules under Actions and for a firewall notice grant the service

access to the domain network.

17.2 Server Offline

If the program “OilControl air” isn't running on the server, the following blinking

message will be displayed in the program status bar on the client:

OilControl air 53

17.2.1 Status Bar Messages

The IP address where the server can be reached on the intranet is displayed in the

program status bar.

“ONLINE” or red blinking “OFFLINE” shows the current status of the server. “OFFLINE”

means that the server software “OilControl air” is not running.

If data is sent from an intranet unit, this is indicated in the status line. UDP and TCP/IP

packets from the units are

received by the OilControl air server. The last data reception is displayed with the

time, protocol, and device number for 4 seconds.

Red blinking “LOCKED” shows that all dispensations are blocked on the server.

54 OilControl air

18 WEB Interface

The lower right in the “OilControl air” program shows how the WEB interface can be

reached. By clicking on the displayed http-URL, the standard browser opens and the

"OilControl air" start page is opened. It’s also possible to scan the barcode with a

smartphone or table that is on the same intranet and to also open the displayed URL.

If the "OilControl air" program is not running, the web interface changes to "Offline"

status after 20 seconds. This affects all HTML websites that access data from the

program database of the server.

18.1 Login

Login takes place with the user data that are administered on the “OilControl air”

server program (see Chapter 10.6).

OilControl air 55

Operation of the web interface takes place via the keypad displayed.

The link to log out is located in the upper left. Without logging out, anyone with

access to the browser can launch dispensations and view orders. Depending on user

rights, it is also possible to create orders.

The language of the web area can be switched under the logout link.

18.2 Orders

All available orders for which a dispensation can occur are shown in the table. A

column can be sorted in ascending or descending order with the click of a mouse.

56 OilControl air

An additional menu can be opened via the symbol at the respective end of the

column. Here, additional columns can be selected or deselected for display. If the

table is displayed after the selection is compressed, the page must be updated once

(press F5).

A job can be selected from the table for dispensation via the "Start" button. The

display scrolls to the right and the operator must enter his or her user code. After

selecting the pumping station and the dispensing point, the desired pre-selection

quantity has to be entered and the order can be started. The quality of the pumping

station must match the quality of the order, see also Chapter 7.1.

The current orders of the month and the previous month are displayed as standard.

OilControl air 57

After starting, the display scrolls to the right again and the job status is updated

every second. Click the "Order List" button to return to the order overview table. A

current dispensation can be interrupted at any time via the “Cancel” button.

After the end of the dispensation, the "Cancel" button is deactivated and the

corresponding status for the job is displayed.

58 OilControl air

18.3 Dispensations

Orders for which a dispensation has already been made are displayed in this table.

The columns can also be sorted in ascending or descending order by clicking on the

header.

The current orders of the month and the previous month are displayed as standard.

18.4 Active

In the "Active Dispensation" menu item, all currently running dispensations are

continuously updated in the table. As soon as a delivery is no longer active, it is

removed from the table. An ongoing dispensation can be stopped at any time by

clicking the "Cancel" button.

18.5 Product

The dispensation quantity of the individual products is output as standard for the last

year as a pie chart. In addition to the legend with the product name, the dispensation

quantity is displayed for the individual parts.

OilControl air 59

By clicking on a product in the legend, this can be displayed or hidden again.

18.6 Creation

All operators with a higher access authorization than a user can create jobs manually.

To get started creating an order, an order number must first be entered. By entering

an item an order number can have several sub-items, that nevertheless all belong to

the same order number.

For product quality 0, any pumping station can issue this order. If for example the

upper group 10 is set up as the product quality, then only pumping stations with the

set quality 11..19 dispense this order. In the case of product quality 15, only one

pumping station would be permitted to dispense the order, if the quality is also set to

15.

The order quantity is the total dispensation quantity for this order number. If the

order quantity for an order is saved as 0.00, then this order can be dispensed without

a dispensation limit. The order can later be set to the status “Complete” by the

“OilControl air” program so that no more dispensations are possible.

60 OilControl air

18.7 View

The view of the display of up to four pumping stations. The pumping stations here

can be dispensing points or tank displays. The last dispensation is displayed for each

pumping station. If a dispensation is started, it is continuously updated.

A tank fill status is updated every 30 seconds.

The display is created with the program “OilControl air” (see Chapter: 9).

OilControl air 61

18.8 Tank

In this display the fill status of all the available tanks are displayed. It is updated

every 30 seconds.

18.9 Devices

The TMS air and LevelController air units can be used to display the delivery points or

tanks with their parameters. The configuration of the devices is only done with the

program “OilControl air” (see Chapter 11).

62 OilControl air

18.10Password

The access password for the login area can be changed here. The current password

must first be entered and then the new one twice for confirmation. The new password

is then saved via the “Change Password” button.

OilControl air 63

64 OilControl air