4
SR NO DESCRIPTION NOS LENGTH WIDTH HEIGHT/ QTY UNIT 1  OHWT BOTTOM B3-B4-B5-B6-B7-B8 1 6 3.15 0.2 0.7 2.65 B9 1 1 2.9 0.2 0.7 0.41 B13 1 1 2.9 0.2 0.7 0.41 1 1 1.05 0.2 0.7 0.15 3.605 CUM 2  OHWT BOTTOM SLAB S6 1 1 3.55 1.40 0.30 1.49 S7 1 1 3.55 2.60 0.30 2.77 S7 1 1 3.55 2.60 0.30 2.77 S8 1 1 3.55 0.65 0.30 0.69 S9 1 1 3.55 1.25 0.30 1.33 OHWT TOP SLAB S13 1 1 3.55 2.60 0.15 1.38 S14 1 1 3.55 2.60 0.15 1.38 S15 1 1 3.55 0.65 0.15 0.35 S16 1 1 3.55 1.25 0.15 0.67 12.83 CUM 3 RCC WALL (OHWT) D1-BLOCK Providing and castin g in situ Ready Mix cement concrete Grade M 25 of trap/granite/quartzite/gneiss metal for R.C.C.wall as per detailed designs and drawings or as directed including centering, formwork, cover blocks, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement). (Excluding reinforcement).(Excluding reinforcement).item includes Plastizer and Pumping of concrete to desired Location. Providing and casting in situ Ready Mix cement concrete Grade M25 of trap/granite/quartzite/gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement).(Excluding reinforcement).item includes Plastizer and Pumping of concrete to desired Location. Providing and casting in situ Ready Mix cement concrete Grade M25 of trap/gran- ite/quartzite/gneiss metal for R.C.C. slabs and landings canopy, waist slab with steps as per detailed designs and drawings including centering, formwork, cover blocks, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement).item includes Plastizer and Pumping of concrete to desired Location

Transcript of OHWT-D1

Page 1: OHWT-D1

 

SR NO DESCRIPTION NOS LENGTH WIDTH HEIGHT/ QTY UNIT

1

 OHWT BOTTOM

B3-B4-B5-B6-B7-B8 1 6 3.15 0.2 0.7 2.65

B9 1 1 2.9 0.2 0.7 0.41

B13 1 1 2.9 0.2 0.7 0.41

1 1 1.05 0.2 0.7 0.15

3.605 CUM

2

 OHWT BOTTOM

SLAB

S6 1 1 3.55 1.40 0.30 1.49

S7 1 1 3.55 2.60 0.30 2.77

S7 1 1 3.55 2.60 0.30 2.77

S8 1 1 3.55 0.65 0.30 0.69

S9 1 1 3.55 1.25 0.30 1.33

OHWT TOP

SLAB

S13 1 1 3.55 2.60 0.15 1.38

S14 1 1 3.55 2.60 0.15 1.38

S15 1 1 3.55 0.65 0.15 0.35

S16 1 1 3.55 1.25 0.15 0.67

12.83 CUM

3

RCC WALL (OHWT)

D1-BLOCK

Providing and casting in situ Ready Mix cement concrete Grade M 25 of

trap/granite/quartzite/gneiss metal for R.C.C.wall as per detailed designs and drawings or as

directed including centering, formwork, cover blocks, compaction and roughening the surface if

special finish is to be provided and curing complete. (Excluding reinforcement). (Excluding

reinforcement).(Excluding reinforcement).item includes Plastizer and Pumping of concrete to

desired Location.

Providing and casting in situ Ready Mix cement concrete Grade M25 of trap/granite/quartzite/gneiss

metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including

centering, formwork, cover blocks, compaction and roughening the surface if special finish is to be

provided and curing complete. (Excluding reinforcement).(Excluding reinforcement).item includes

Plastizer and Pumping of concrete to desired Location.

Providing and casting in situ Ready Mix cement concrete Grade M25 of trap/gran-

ite/quartzite/gneiss metal for R.C.C. slabs and landings canopy, waist slab with steps as per detailed

designs and drawings including centering, formwork, cover blocks, compacting and roughening the

surface if special finish is to be provided and curing complete. (Excluding reinforcement).item

includes Plastizer and Pumping of concrete to desired Location

Page 2: OHWT-D1

 

1 2 3.55 0.20 3.45 4.90

1 2 7.30 0.20 3.45 10.07

1 3 3.15 0.20 3.45 6.52

21.494 CUM

4

Factor

Wall 0.120 21.49 2.58

Beam 0.150 3.61 0.54

Slab 0.125 12.83 1.60

4.724 MT

5

INTERNAL PLASTER (OHWT)

1 2 3.15 3.45 21.74

1 2 2.4 3.45 16.56

1 2 3.15 3.45 21.74

1 2 2.4 3.45 16.56

1 2 1.05 3.45 7.25

1 2 3.15 3.45 21.74

105.57 SQM

6

WATERPROFFING (TOP)

OHWT 1 1 3.55 7.3 25.92

1 -1 3.55 0.45 -1.60

24.318 SQM

7

WATERPROFFING (INTERNAL)

Providing and fixing in position TMT-FE-500 reinforcement of various diameters for R.C.C. pile caps,

footings, foundations, slabs, beams columns, canopies, staircase, newels, hajjas, lintels pardis,

copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending,

hooking the bars, binding with wires or tack welding and supporting as required complete.

Providing and applying water proofing treatment using acrylic polymer modified cement based water

proofing coating with fibre glass mesh, mixing at the rate of powder to liquid (2:1) by weight covering

9 to 10 sqm/kg with two coat (using Dr. Fixit or alike of chemicals for masonary and concrete surface

by brush covering 7 years guarantee on Stamp Papers etc. complete.

Providing & laying water proof treatment of terrace slab with B.B. Coba in all position with an

average thickness of 112 mm consisting specialised materials as per the manufactures specifications

and covering 10 years guarantee on court fee stamp paper including all lead, lift etc. complete

Providing internal cement plaster 12 mm thick in a single coats in b) cement mortar 1:4 without

neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing complete.

over acrylic polymer modified cement based water proofing coating paid seperately

Page 3: OHWT-D1

 

OHWT

1 2 3.15 3.45 21.74

1 2 2.4 3.45 16.56

1 2 3.15 3.45 21.74

1 2 2.4 3.45 16.56

1 2 1.05 3.45 7.25

1 2 3.15 3.45 21.74

105.57 SQM

8

EXTERNAL

OHWT 1 2 3.55 3.9 27.69

1 1 7.3 3.9 28.47

1 1 7.1 3.9 27.69

1 2 3.35 3.9 26.13

109.98 SQM

9

Fire Water Tank 1 1 3.4 3.40

Flushing Tank 1 1 3.4 3.40

Domestic Water Tank 1 1 3.4 3.40

1 1 6.7 6.70

16.900 Rmt

10

RCC WALL (OHWT) 1 2 3.55 3 21.30

1 2 7.30 3 43.80

1 3 3.15 3 28.35

93.450 Rmt

11

a) Heavy duty (225 kg) 1 3 3.00

Providing Water stops at the joints as a continuous diaphragm to contain the filler material and/or to

exclude passage of water or any other material into or out of the structure confirimng to IS 12200.

Rate shall include materials, labour, joining all complete as per drawings, specification and as

directed by the engineer. ( 300 mm wide, 10 to 25 mm thick central bubbles type)

Providing and fixing 45 cm wide mild steel ladder of 40mm x 6 mm mild steel flat stringers and steps

of 18mm dia mild steel bar for water tank including fixing it in (1:2:4) M-15 cement crete block 60cm

x 30cm x 30 cm & painting the ladder complete.

Providing and fixing reinforced cement concrete

cover of size 90 cm x 45 cm with frame over inspection

chamber etc. complete.

Spec. No.: As directed by Engineer in charge.

Providing and applying two coats of exterior weathershield paint of approved manufacture and of

approved colour to the plastered/concrete surfaces including cleaning, prepairing the

plaster/concrete surface, applying primer coat, scaffolding if necessary, and watering the surface for

two days complete.

Page 4: OHWT-D1

 