ODU Branch Pipe Installation Manual FQZHW-0XN1D

2
ID:15.9 ID:19.1 ID:6.4 M(Two) N(Two) P(Two) ID:15.9 ID:19.1 ID:6.4 M N P Name Gas side joints Branch List FQZHW- 02N1D FQZHW- 03N1D FQZHW- 04N1D Appearance And Connection Sketch Of FQZHW-02N1D 1 ID:31.8 0D:34.9 ID:31.8 ID:38.1 ID:34.9 0D:31.8 ID:25.4 0D:31.8 ID:38.1 ID:41.3 ID:31.8 0D:31.8 ID:31.8 ID:25.4 ID:31.8 0D:34.9 ID:31.8 ID:38.1 ID:34.9 0D:31.8 ID:25.4 0D:31.8 0D:34.9 ID:34.9 ID:38.1 ID:34.9 ID:31.8 ID:31.8 0D:31.8 ID:25.4 0D:31.8 ID:38.1 ID:41.3 ID:31.8 0D:31.8 ID:31.8 ID:25.4 ID:31.8 ID:25.4 ID:31.8 ID:25.4 ID:41.3 ID:44.5 ID:31.8 0D:31.8 ID:31.8 ID:25.4 ID:15.9 ID:19.1 ID:15.9 ID:15.9 0D:15.9 ID:12.7 ID:12.7 0D:15.9 0D:25.4 ID:25.4 ID:22.2 ID:22.2 ID:15.9 0D:15.9 ID:15.9 ID:12.7 ID:19.1 ID:22.2 ID:15.9 0D:15.9 ID:15.9 ID:12.7 ID:15.9 ID:15.9 ID:19.1 ID:15.9 0D:15.9 ID:12.7 ID:12.7 0D:15.9 ID:15.9 0D:19.1 ID:19.1 ID:15.9 ID:22.2 ID:19.1 ID:15.9 0D:15.9 ID:12.7 ID:12.7 0D:15.9 ID:19.1 0D:22.2 ID:22.2 ID:19.1 ID:15.9 0D:15.9 ID:15.9 ID:12.7 ID:31.8 ID:25.4 Liquid side joints Gas balance joint 1 Gas balance joint 2 Oil balance Table.1 Choice FQZHW-02N1D Branch pipes for outdoor unit Table.2 FQZHW-03N1D FQZHW-04N1D Pipe Size 8HP 36~50HP 26~34HP 10HP 16HP 24HP 68~88HP 52~66HP Please select and install the branch pipe according to outdoor unit installation manual and actual installation conditions. Installation Precaution 1) Pay attention to the distance of straight horizontal pipe. a.The straight horizontal pipe’s distance between two adjacent branch pipes should ≥0.5m. b.The straight horizontal pipe’s distance which outdoor unit connecting behind the branch pipe should ≥0.5m. Outdoor unit Above 0.5m Outdoor unit Outdoor unit Above 0.5m 2 Y1 Y6 Y3 Y2 Y1 Y1 Y7 Y1 Y7 Y1 Y8 Y5 Y4 Y6 Y2 Y1 Y6 Y2 Q1 Q3 Q4 Q1 Q1 Q1 Q1 Q1 Q2 Q2 Q2 Q7 Q7 Q5 Q5 Q6 Installation Notices Abandon Cut from the middle Cut from the bottom Cut from the bottom Fig.1 Fig.2 Fig.3 Fig.4 1)Select the proper branch model according to table2. 2)According to the actual piping size and cut off the needless parts with special tools such as cutter, take the FQZHW-02N1D gas side for example and the operating steps as follow: a.When selecting model FQZHW-02N1D, the actual object as display in Fig.1, and then suppose that the outlet pipe of the machine isΦ31.8, main pipe isΦ38.1. As display in Fig.2, cut the standalone connecting pipe Q1 of the branch pipe component. b.As display in Fig.2, weld the standalone connecting pipe Q1, Q3 with the U-shape three direct link s Q4; abandon the standalone connecting pipe Q2 because selected pipe sizeΦ31.8 can directly connect with the un-welded side of U-shape three direct links. c.As display in Fig.3, weld the branch pipe components with the field pipes. 3)Particularly notice the followings: a.When the actual pipe size matches with the un-welded side of U-shape three direct links, weld the pipe with the U-shape three direct links. b.For the connecting pipes Q3 and Q7, if they need to be cut, please cut in the bottom of the flaring as display in Fig. 4. Q1 Q2 Q1 Q2 Q1 Q7 Q4 Q4 Q3 Q3 Q4 Q3 Thank you very much for purchasing our air conditioner, Before using your air conditioner , please read this manual carefully and keep it for future reference. MD12I-042DW 16111700000019 OUTDOOR UNIT BRANCH PIPE INSTALLATION MANUAL Appearance And Connection Sketch Of FQZHW-03N1D Appearance And Connection Sketch Of FQZHW-04N1D 2 3 4 Incision Cut off the part from middle site Branch pipe Field pipe Connection part Keep the cutting direction and the copper pipe in a vertical position Heat insulation material (2 sets) (4 sets) (6 sets) Heat insulation 1) Example of connected branch. Be sure to insulate the brahches against heat Field pipe Field pipe Branch (supplied) Field pipe heat insulation material(supplied) Tape Field piping heat insulation material 2) Use the supplied heat insulation material to insulate the branches against heat. 3) Apply the heat insulation material and seal all connections with tape. Horizontally Placing Branch Pipe B A Direction A Direction B ±10° ±10° ±10° A horizontally incline angle should not larger than 10°. Adhesive paper(tear off before pasting) W1 W2 W1 W2 W1 W2 W1 W2(Master unit) Gas pipe joint Q4 Gas pipe joint Q2 Field piping Φ25.4 or Φ31.8 (According to the W1 unit factory diameterField piping Φ25.4 or Φ31.8 (According to the unit factory diameterField piping Φ25.4 or Φ31.8 (According to the unit factory diameterGas pipe joint Q1 Gas pipe joint Q3 Field piping Φ6.35 Elbow (Unit accessoriesOil balance pipe Gas pipe Liquid pipe Welding Welding Field piping, select piping according to table 3 Field piping, select piping according to table 3 Field piping Φ12.7 or Φ15.9 (According to the unit factory diameterField piping Φ12.7 or Φ15.9 (According to the unit factory diameterLiquid pipe joint Y3 Liquid pipe joint Y1 Liquid pipe joint Y6 Liquid pipe joint Y2 V5X outdoor unit pipe connection Field piping Φ12.7 or Φ15.9 (According to the unit factory diameterField piping Φ12.7 or Φ15.9 (According to the unit factory diameterField piping Φ12.7 or Φ15.9 (According to the unit factory diameterField piping Φ12.7 or Φ15.9 (According to the unit factory diameterField piping Φ12.7 or Φ15.9 (According to the unit factory diameterField piping Φ12.7 or Φ15.9 (According to the unit factory diameterField piping Φ12.7 or Φ15.9 (According to the unit factory diameterField piping Φ12.7 or Φ15.9 (According to the unit factory diameterLiquid pipe joint Y4 Liquid pipe joint Y6 Liquid pipe joint Y7 W1 W2 W3(Master unit) W1 W2 W3 Field piping Φ19.1 Liquid pipe joint Y2 Gas pipe joint Q1(2 sets) Gas pipe joint Q7 Gas pipe joint Q2 Gas pipe joint Q1 (3 sets) W1 W1 W2 W2 W3 W3 Gas pipe joint Q5 Field piping Φ38.1 Field piping Φ25.4 or Φ31.8 (According to the unit factory diameterW1 W2 W3 W4 Liquid pipe joint Y5 Liquid pipe joint Y8 Liquid pipe joint Y7 Liquid pipe joint Y6 W1 W2 W3 W4(Master unit) Field piping Φ22.2 Field piping Φ19.1 Liquid pipe joint Y2 Oil balance pipe P Oil balance pipe P W1 W2 W3 W4 Gas pipe joint Q7 Gas pipe joint Q6 Gas pipe joint Q5 W1 W2 W3 Gas pipe joint Q2 W4 Field piping Φ41.3 Field piping Φ38.1 Note: 1) The largest capacity outdoor unit should be set as master unit. 2) The above figure is only available for V5X Series. 3) The unit factory diameter: 8/10HP Gas pipe: Φ25.4 Liquid pipe: Φ12.7 12HP Gas pipe: Φ28.6 Liquid pipe: Φ15.9 14/16HP Gas pipe: Φ31.8 Liquid pipe: Φ15.9 18/20/22HP Gas pipe: Φ31.8 Liquid pipe: Φ19.1 Note: 1) The largest capacity outdoor unit should be set as master unit. 2) The above figure is only available for V5X Series. 3) The unit factory diameter: 8/10HP Gas pipe: Φ25.4 Liquid pipe: Φ12.7 12HP Gas pipe: Φ28.6 Liquid pipe: Φ15.9 14/16HP Gas pipe: Φ31.8 Liquid pipe: Φ15.9 18/20/22HP Gas pipe: Φ31.8 Liquid pipe: Φ19.1 Note: 1) The largest capacity outdoor unit should be set as master unit. 2) The above figure is only available for V5X Series. 3) The unit factory diameter: 8/10HP Gas pipe: Φ25.4 Liquid pipe: Φ12.7 12HP Gas pipe: Φ28.6 Liquid pipe: Φ15.9 14/16HP Gas pipe: Φ31.8 Liquid pipe: Φ15.9 18/20/22HP Gas pipe: Φ31.8 Liquid pipe: Φ19.1 Field piping Φ25.4 orΦ31.8 (According to the unit factory diameterField piping Φ25.4 or Φ31.8 (According to the unit factory diameterField piping Φ25.4 or Φ31.8 (According to the unit factory diameterField piping Φ25.4 or Φ31.8 (According to the unit factory diameterField piping Φ25.4 or Φ31.8 (According to the unit factory diameterField piping Φ25.4 or Φ31.8 (According to the unit factory diameterField piping Φ25.4 or Φ31.8 (According to the unit factory diameterField piping Φ25.4 or Φ31.8 (According to the unit factory diameterField piping Φ6.35 Field piping Φ6.35 Elbow (Unit accessoriesElbow (Unit accessoriesOil balance pipe Oil balance pipe Oil balance pipe M Gas pipe Gas pipe Liquid pipe Liquid pipe Welding Field piping Φ6.35 Field piping Φ6.35 Field piping Φ6.35 Field piping Φ6.35 Welding Welding Welding Welding Welding Welding Field piping, select piping according to table 3 Field piping, select piping according to table 3 Field piping, select piping according to table 3 Field piping, select piping according to table 3 Liquid pipe joint Y1 (2 sets) Liquid pipe joint Y1 (3 sets) Quantity of outdoor units Branch pipe

Transcript of ODU Branch Pipe Installation Manual FQZHW-0XN1D

ID:15.9ID:19.1

ID:6.4

M(Two) N(Two) P(Two)

ID:15.9 ID:19.1ID:6.4

M N P

Name Gas side joints

Branch List

FQZHW-02N1D

FQZHW-03N1D

FQZHW-04N1D

Appearance And Connection Sketch Of FQZHW-02N1D

1

ID:31.8

0D:34.9

ID:31.8ID:38.1

ID:34.90D:31.8

ID:25.4

0D:31.8 ID:38.1

ID:41.3

ID:31.8

0D:31.8ID:31.8ID:25.4

ID:31.8

0D:34.9

ID:31.8ID:38.1

ID:34.90D:31.8

ID:25.4

0D:31.8

0D:34.9ID:34.9

ID:38.1

ID:34.9

ID:31.8

ID:31.8

0D:31.8

ID:25.4

0D:31.8

ID:38.1

ID:41.3

ID:31.8

0D:31.8ID:31.8ID:25.4

ID:31.8ID:25.4

ID:31.8ID:25.4

ID:41.3

ID:44.5

ID:31.8

0D:31.8ID:31.8ID:25.4

ID:15.9

ID:19.1

ID:15.9

ID:15.9

0D:15.9ID:12.7

ID:12.7

0D:15.9

0D:25.4ID:25.4ID:22.2

ID:22.2ID:15.9

0D:15.9ID:15.9ID:12.7

ID:19.1ID:22.2

ID:15.9

0D:15.9ID:15.9ID:12.7

ID:15.9

ID:15.9

ID:19.1

ID:15.9

0D:15.9ID:12.7

ID:12.7

0D:15.9

ID:15.9

0D:19.1ID:19.1

ID:15.9

ID:22.2

ID:19.1ID:15.9

0D:15.9ID:12.7

ID:12.7

0D:15.9

ID:19.10D:22.2ID:22.2

ID:19.1ID:15.9

0D:15.9ID:15.9ID:12.7

ID:31.8ID:25.4

Liquid side jointsGas balance

joint 1Gas balance

joint 2 Oil balance

Table.1

Choice

FQZHW-02N1D

Branch pipes for outdoor unit

Table.2

FQZHW-03N1D

FQZHW-04N1D

Pipe Size

8HP

36~50HP26~34HP

10HP

16HP

24HP

68~88HP52~66HP

Please select and install the branch pipe according to outdoor unit installation manual and actual installation conditions.

Installation Precaution

1) Pay attention to the distance of straight horizontal pipe.

a.The straight horizontal pipe’s distance between two adjacent branch pipes should ≥0.5m. b.The straight horizontal pipe’s distance which outdoor unit connecting behind the branch pipe should ≥0.5m.

Outdoor unit

Above 0.5m

Outdoor unit Outdoor unit

Above 0.5m

2

Y1

Y6 Y3Y2

Y1 Y1

Y7

Y1

Y7

Y1

Y8 Y5

Y4Y6

Y2

Y1

Y6Y2

Q1

Q3Q4

Q1

Q1 Q1

Q1

Q1

Q2

Q2

Q2

Q7

Q7Q5

Q5

Q6

Installation Notices

Abandon

Cut from the middle

Cut from the bottom

Cut from the bottom

Fig.1 Fig.2

Fig.3 Fig.4

1)Select the proper branch model according to table2.2)According to the actual piping size and cut off the needless parts with special tools such as cutter, take the FQZHW-02N1D gas side for example and the operating steps as follow: a.When selecting model FQZHW-02N1D, the actual object as display in Fig.1, and then suppose that the outlet pipe of the machine isΦ31.8, main pipe isΦ38.1. As display in Fig.2, cut the standalone connecting pipe Q1 of the branch pipe component. b.As display in Fig.2, weld the standalone connecting pipe Q1, Q3 with the U-shape three direct link s Q4; abandon the standalone connecting pipe Q2 because selected pipe sizeΦ31.8 can directly connect with the un-welded side of U-shape three direct links. c.As display in Fig.3, weld the branch pipe components with the field pipes. 3)Particularly notice the followings: a.When the actual pipe size matches with the un-welded side of U-shape three direct links, weld the pipe with the U-shape three direct links. b.For the connecting pipes Q3 and Q7, if they need to be cut, please cut in the bottom of the flaring as display in Fig. 4.

Q1

Q2

Q1

Q2

Q1 Q7

Q4 Q4 Q3Q3

Q4 Q3

Thank you very much for purchasing our air conditioner, Before using your air conditioner , please read this manual carefully and keep it for future reference.

MD12I-042DW16111700000019OUTDOOR UNIT BRANCH PIPE INSTALLATION MANUAL Appearance And Connection Sketch Of FQZHW-03N1D

Appearance And Connection Sketch Of FQZHW-04N1D

2

3

4

Incision

Cut off the part from middle site

Branch pipe

Field pipeConne

ction

part

Keep the cutting direction and the copper pipe in a vertical position

Heat insulation material

(2 sets)

(4 sets)

(6 sets)

Heat insulation

1) Example of connected branch.

Be sure to insulate the brahches against heat

Field pipe

Field pipe

Branch (supplied)

Field pipe

heat insulation material(supplied)

Tape

Field piping heat insulation material

2) Use the supplied heat insulation material to insulate the branches against heat.

3) Apply the heat insulation material and seal all connections with tape.

Horizontally Placing Branch Pipe

B

A

Direction A Direction B

� ±10°

� ±10°� ±10°

A horizontally incline angle should not larger than 10°.

Adhesive paper(tear off before pasting)

W1

W2

W1

W2

W1

W2

W1

W2(Master unit)

Gas pipe joint Q4

Gas pipe joint Q2 Field piping Φ25.4 or Φ31.8(According to the W1 unit factory diameter)

Field piping Φ25.4 or Φ31.8(According to the

unit factory diameter)

Field piping Φ25.4 or Φ31.8(According to the

unit factory diameter)

Gas pipe joint Q1

Gas pipe joint Q3

Field piping Φ6.35

Elbow(Unit accessories)

Oil balance pipe

Gas pipe

Liquid

pipe

Welding

Welding

Field piping, select piping according to table 3

Field piping, select piping according to table 3

Field piping Φ12.7 or Φ15.9(According to the

unit factory diameter)

Field piping Φ12.7 or Φ15.9(According to the

unit factory diameter)

Liquid pipe joint Y3

Liquid pipe joint Y1

Liquid pipe joint Y6

Liquid pipe joint Y2

V5X outdoor unit pipe connection

Field piping Φ12.7 or Φ15.9(According to the

unit factory diameter)

Field piping Φ12.7 or Φ15.9(According to the

unit factory diameter)

Field piping Φ12.7 or Φ15.9(According to the

unit factory diameter)

Field piping Φ12.7 or Φ15.9(According to the

unit factory diameter)

Field piping Φ12.7 or Φ15.9(According to the

unit factory diameter)

Field piping Φ12.7 or Φ15.9(According to the

unit factory diameter) Field piping Φ12.7 or Φ15.9(According to the

unit factory diameter)

Field piping Φ12.7 or Φ15.9(According to the

unit factory diameter)

Liquid pipe joint Y4

Liquid pipe joint Y6

Liquid pipe joint Y7

W1

W2

W3(Master unit)

W1

W2

W3

Field piping Φ19.1

Liquid pipe joint Y2

Gas pipe joint Q1(2 sets)

Gas pipe joint Q7

Gas pipe joint Q2

Gas pipe joint Q1 (3 sets)

W1

W1

W2

W2

W3

W3

Gas pipe joint Q5

Field piping Φ38.1

Field piping Φ25.4 or Φ31.8(According to the

unit factory diameter)

W1

W2

W3

W4

Liquid pipe joint Y5Liquid pipe joint Y8

Liquid pipe joint Y7

Liquid pipe joint Y6

W1

W2

W3

W4(Master unit)

Field piping Φ22.2

Field piping Φ19.1

Liquid pipe joint Y2

Oil balance pipe P

Oil balance pipe P

W1

W2

W3

W4

Gas pipe joint Q7

Gas pipe joint Q6

Gas pipe joint Q5

W1

W2

W3

Gas pipe joint Q2

W4

Field piping Φ41.3

Field piping Φ38.1

Note:1) The largest capacity outdoor unit should be set as master unit.2) The above figure is only available for V5X Series.3) The unit factory diameter:

8/10HP

Gas pipe: Φ25.4Liquid pipe: Φ12.7

12HP

Gas pipe: Φ28.6Liquid pipe: Φ15.9

14/16HP

Gas pipe: Φ31.8Liquid pipe: Φ15.9

18/20/22HP

Gas pipe: Φ31.8Liquid pipe: Φ19.1

Note:1) The largest capacity outdoor unit should be set as master unit.2) The above figure is only available for V5X Series.3) The unit factory diameter:

8/10HP

Gas pipe: Φ25.4Liquid pipe: Φ12.7

12HP

Gas pipe: Φ28.6Liquid pipe: Φ15.9

14/16HP

Gas pipe: Φ31.8Liquid pipe: Φ15.9

18/20/22HP

Gas pipe: Φ31.8Liquid pipe: Φ19.1

Note:1) The largest capacity outdoor unit should be set as master unit.2) The above figure is only available for V5X Series.3) The unit factory diameter:

8/10HP

Gas pipe: Φ25.4Liquid pipe: Φ12.7

12HP

Gas pipe: Φ28.6Liquid pipe: Φ15.9

14/16HP

Gas pipe: Φ31.8Liquid pipe: Φ15.9

18/20/22HP

Gas pipe: Φ31.8Liquid pipe: Φ19.1

Field piping Φ25.4 orΦ31.8(According to the

unit factory diameter)

Field piping Φ25.4 or Φ31.8(According to the

unit factory diameter)

Field piping Φ25.4 or Φ31.8(According to the

unit factory diameter)Field piping Φ25.4 or Φ31.8

(According to the unit factory diameter)

Field piping Φ25.4 or Φ31.8(According to the

unit factory diameter)

Field piping Φ25.4 or Φ31.8(According to the

unit factory diameter)

Field piping Φ25.4 or Φ31.8(According to the

unit factory diameter)

Field piping Φ25.4 or Φ31.8(According to the

unit factory diameter)

Field piping Φ6.35

Field piping Φ6.35

Elbow(Unit accessories)

Elbow(Unit accessories)

Oil balance pipe

Oil balance pipe

Oil balance pipe M

Gas pipe

Gas pipe

Liquid

pipe

Liquid

pipe

Welding

Field piping Φ6.35

Field piping Φ6.35

Field piping Φ6.35

Field piping Φ6.35

Welding

Welding

Welding

Welding

Welding

Welding

Field piping, select piping according to table 3

Field piping, select piping according to table 3

Field piping, select piping according to table 3

Field piping, select piping according to table 3

Liquid pipe joint Y1 (2 sets)

Liquid pipe joint Y1 (3 sets)

Quantity of outdoor units

Branch pipe

更改页 更改人更改内容日期 版本号

更改记录表(仅做说明用,不做菲林)

2016.1.27 B → C陈海清李波

1、Pipe Size(Table.3),管径尺寸更改;2、Appearance And Connection Sketch Of FQZHW-02/03/04N1D图例更改;3、说明书图号及编号升级。

2018.3.28 C → D 黎浩标1、机型示意图删去美的LOGO;2、说明书图号及编号升级。

此页不做菲林,只做说明材料:双胶纸100g/㎡大小:A1,厂家折叠成A5供货黑白印刷,内容清晰