Obstruction Manager
1WRAP 0972E
![Page 2: Obstruction Manager 1 WRAP 0972E. Obstruction Manager Calculates the interference to radars caused by wind power stations and masts 2 WRAP 0972E.](https://reader035.fdocuments.in/reader035/viewer/2022062518/56649ea95503460f94bacb33/html5/thumbnails/2.jpg)
Obstruction Manager
• Calculates the interference to radars caused by wind power stations and masts
2WRAP 0972E
![Page 3: Obstruction Manager 1 WRAP 0972E. Obstruction Manager Calculates the interference to radars caused by wind power stations and masts 2 WRAP 0972E.](https://reader035.fdocuments.in/reader035/viewer/2022062518/56649ea95503460f94bacb33/html5/thumbnails/3.jpg)
Introduction
• Calculates the signal-to-interference ratio, S/I.
• The signal is the signal radar target radar
• The interfering signal is the sum of the signals:– radar target obstacle radar– radar obstacle target radar– radar obstacle target obstacle radar
• Compares the calculated S/I to the radar receiver required S/I.
3WRAP 0972E
![Page 4: Obstruction Manager 1 WRAP 0972E. Obstruction Manager Calculates the interference to radars caused by wind power stations and masts 2 WRAP 0972E.](https://reader035.fdocuments.in/reader035/viewer/2022062518/56649ea95503460f94bacb33/html5/thumbnails/4.jpg)
Workflow
• The user inputs data for obstacles• For each new obstacle
– Check for aeronautical stations within 3 km from wind power stations (3.3 km for masts)
– Search for possible interfered radar stations within 100 km limit from obstacle
4WRAP 0972E
![Page 5: Obstruction Manager 1 WRAP 0972E. Obstruction Manager Calculates the interference to radars caused by wind power stations and masts 2 WRAP 0972E.](https://reader035.fdocuments.in/reader035/viewer/2022062518/56649ea95503460f94bacb33/html5/thumbnails/5.jpg)
Workflow (cont.)
– For each possible interfered radar station• Check forbidden area (limit 2 km)• Check if obstacle within interference free area
(limit 100 km in operational sector of radar)• Check if obstacle is visible from the radar• Search for existing obstacles in ObsMan and
FIA databases• Check if existing obstacles is affected by the
new obstacles• Check new obstacles (including possible
group effects)
5WRAP 0972E
![Page 6: Obstruction Manager 1 WRAP 0972E. Obstruction Manager Calculates the interference to radars caused by wind power stations and masts 2 WRAP 0972E.](https://reader035.fdocuments.in/reader035/viewer/2022062518/56649ea95503460f94bacb33/html5/thumbnails/6.jpg)
Wind power stationradar cross section
• The wind power station radar cross section is calculated in 3 different depending on the angle β.
• β = 0° is called backward propagation• 0°<β<180° is called subsidiary static propagation• β = 180° is called forward propagation
6WRAP 0972E
RD
RI
ri
αβ
φ
Radar
Wind power station
Calculation point
![Page 7: Obstruction Manager 1 WRAP 0972E. Obstruction Manager Calculates the interference to radars caused by wind power stations and masts 2 WRAP 0972E.](https://reader035.fdocuments.in/reader035/viewer/2022062518/56649ea95503460f94bacb33/html5/thumbnails/7.jpg)
Wind power stationradar cross section
• The wind power station radar cross section is highly dependent on vertical incidence angle
7WRAP 0972E
![Page 8: Obstruction Manager 1 WRAP 0972E. Obstruction Manager Calculates the interference to radars caused by wind power stations and masts 2 WRAP 0972E.](https://reader035.fdocuments.in/reader035/viewer/2022062518/56649ea95503460f94bacb33/html5/thumbnails/8.jpg)
Wind power stations, input window
8WRAP 0972E
![Page 9: Obstruction Manager 1 WRAP 0972E. Obstruction Manager Calculates the interference to radars caused by wind power stations and masts 2 WRAP 0972E.](https://reader035.fdocuments.in/reader035/viewer/2022062518/56649ea95503460f94bacb33/html5/thumbnails/9.jpg)
Mast parameters
Mast parameters• Mast height• Bottom width of the mast• Top width of the mast
• The radar cross section depends on the mast dimensions and the angle of incidence.
9WRAP 0972E
![Page 10: Obstruction Manager 1 WRAP 0972E. Obstruction Manager Calculates the interference to radars caused by wind power stations and masts 2 WRAP 0972E.](https://reader035.fdocuments.in/reader035/viewer/2022062518/56649ea95503460f94bacb33/html5/thumbnails/10.jpg)
Databases
The calculation uses three different databases:• FIA
– Aviation obstacle database. – Contains masts and wind power stations (read-
only).
• ObsmandB– Contains masts and wind power stations defined
in Obsman.
• WRAPdB– Contains radar stations.
10WRAP 0972E
![Page 11: Obstruction Manager 1 WRAP 0972E. Obstruction Manager Calculates the interference to radars caused by wind power stations and masts 2 WRAP 0972E.](https://reader035.fdocuments.in/reader035/viewer/2022062518/56649ea95503460f94bacb33/html5/thumbnails/11.jpg)
Terrain blocking
• The obstacle can be blocked by the terrain• The radar cross section is compensated
for the limited visibility
11WRAP 0972E
Wind power station
Radar
![Page 12: Obstruction Manager 1 WRAP 0972E. Obstruction Manager Calculates the interference to radars caused by wind power stations and masts 2 WRAP 0972E.](https://reader035.fdocuments.in/reader035/viewer/2022062518/56649ea95503460f94bacb33/html5/thumbnails/12.jpg)
Calculation area
• The calculations are performed at points along aline 60 km from the radar. The length of the line are limited 2 x lobe width (3 dB)
• The resolution of the calculation points are the same as in the height database
12WRAP 0972E
60 kmRadar
κ
![Page 13: Obstruction Manager 1 WRAP 0972E. Obstruction Manager Calculates the interference to radars caused by wind power stations and masts 2 WRAP 0972E.](https://reader035.fdocuments.in/reader035/viewer/2022062518/56649ea95503460f94bacb33/html5/thumbnails/13.jpg)
Calculation result
13WRAP 0972E
![Page 14: Obstruction Manager 1 WRAP 0972E. Obstruction Manager Calculates the interference to radars caused by wind power stations and masts 2 WRAP 0972E.](https://reader035.fdocuments.in/reader035/viewer/2022062518/56649ea95503460f94bacb33/html5/thumbnails/14.jpg)
Detailed calculation result
14WRAP 0972E
![Page 15: Obstruction Manager 1 WRAP 0972E. Obstruction Manager Calculates the interference to radars caused by wind power stations and masts 2 WRAP 0972E.](https://reader035.fdocuments.in/reader035/viewer/2022062518/56649ea95503460f94bacb33/html5/thumbnails/15.jpg)
Reports
15WRAP 0972E
There are three different types of reports in the Obsman tool.• Answering letter• Summary of all the cases• Detailed report of a case
![Page 16: Obstruction Manager 1 WRAP 0972E. Obstruction Manager Calculates the interference to radars caused by wind power stations and masts 2 WRAP 0972E.](https://reader035.fdocuments.in/reader035/viewer/2022062518/56649ea95503460f94bacb33/html5/thumbnails/16.jpg)
Answering letter
16WRAP 0972E
![Page 17: Obstruction Manager 1 WRAP 0972E. Obstruction Manager Calculates the interference to radars caused by wind power stations and masts 2 WRAP 0972E.](https://reader035.fdocuments.in/reader035/viewer/2022062518/56649ea95503460f94bacb33/html5/thumbnails/17.jpg)
Summary of all cases
17WRAP 0972E
![Page 18: Obstruction Manager 1 WRAP 0972E. Obstruction Manager Calculates the interference to radars caused by wind power stations and masts 2 WRAP 0972E.](https://reader035.fdocuments.in/reader035/viewer/2022062518/56649ea95503460f94bacb33/html5/thumbnails/18.jpg)
Detailed case report
18WRAP 0972E