NuRONWater Network Monitoring
Detect problems in real time before they turn into headaches
![Page 2: NuRON - Water Network Monitoring & Leak Detection](https://reader035.fdocuments.in/reader035/viewer/2022081511/559515481a28abe9748b46c6/html5/thumbnails/2.jpg)
The Issue Operational and Networks MonitoringoPeak day zone performanceoVirtual water supply sub-zonesoConsumption analysisoAlarms at critical network locationsoWater quality
![Page 3: NuRON - Water Network Monitoring & Leak Detection](https://reader035.fdocuments.in/reader035/viewer/2022081511/559515481a28abe9748b46c6/html5/thumbnails/3.jpg)
The Issue o Data collection for network model
calibrationo Critical/Large Customer (similar to
Hydroshare)- usage volumes and profiles- customers can self monitor usage
o Leakage Detection (Reduction in Non-Revenue Water)
- MNF Analysis, - overnight acoustic response
![Page 4: NuRON - Water Network Monitoring & Leak Detection](https://reader035.fdocuments.in/reader035/viewer/2022081511/559515481a28abe9748b46c6/html5/thumbnails/4.jpg)
The SolutionIntegrated Monitoringo Flow, Pressure, Acoustic, Data Logger
![Page 5: NuRON - Water Network Monitoring & Leak Detection](https://reader035.fdocuments.in/reader035/viewer/2022081511/559515481a28abe9748b46c6/html5/thumbnails/5.jpg)
The Solution- Battery powered stations
(up to 5-10 year battery life)- Utilises mobile telephone networks - Data collection, storage and relay capabilities- Real time alarms- Multiple data inputs (flow, pressure,
temperature, water quality, pit lid status, etc.)
![Page 6: NuRON - Water Network Monitoring & Leak Detection](https://reader035.fdocuments.in/reader035/viewer/2022081511/559515481a28abe9748b46c6/html5/thumbnails/6.jpg)
The Solution- Acoustic sensing (standalone monitors –
incorporated into system)- Automated reporting- Easily retrofitted to existing assets- Fully IP68 rated (can be fully submersed in
water)- Lockable pits- Web based user dashboard
![Page 7: NuRON - Water Network Monitoring & Leak Detection](https://reader035.fdocuments.in/reader035/viewer/2022081511/559515481a28abe9748b46c6/html5/thumbnails/7.jpg)
The BenefitsOperational InsightoWater zonal leak detectionoLow cost installationoReal time water quality and pressure managementoLow maintenanceoFlexibility in installation
![Page 8: NuRON - Water Network Monitoring & Leak Detection](https://reader035.fdocuments.in/reader035/viewer/2022081511/559515481a28abe9748b46c6/html5/thumbnails/8.jpg)
The BenefitsLow CostoTraditional SCADA site would be 30k+o Equivalent NuRON site is:
- Pressure Site -> $3k-$5k
![Page 9: NuRON - Water Network Monitoring & Leak Detection](https://reader035.fdocuments.in/reader035/viewer/2022081511/559515481a28abe9748b46c6/html5/thumbnails/9.jpg)
The Resultso Multitude of low-powered,
real-time monitoring systems deployed on a large scale throughout the water and sewer networks to read pressure/flow/water quality
o Previously cost prohibitive, but new technology has paved the way
![Page 10: NuRON - Water Network Monitoring & Leak Detection](https://reader035.fdocuments.in/reader035/viewer/2022081511/559515481a28abe9748b46c6/html5/thumbnails/10.jpg)
The Resultso Virtual DMA’s Varying Sizeo All the benefits of a physical
DMA without the problems of– valve management–Water quality
![Page 11: NuRON - Water Network Monitoring & Leak Detection](https://reader035.fdocuments.in/reader035/viewer/2022081511/559515481a28abe9748b46c6/html5/thumbnails/11.jpg)
Leak Detection TrialPermanent InstallationsoNuRON Station Technology oGeneration of virtual water supply zonesoMinimum Night Flows (MNF) trends oOvernight acoustic noise trends oDeveloping automated reporting systems
![Page 12: NuRON - Water Network Monitoring & Leak Detection](https://reader035.fdocuments.in/reader035/viewer/2022081511/559515481a28abe9748b46c6/html5/thumbnails/12.jpg)
Leak Detection TrialDataoData available with detail not previously possible
![Page 13: NuRON - Water Network Monitoring & Leak Detection](https://reader035.fdocuments.in/reader035/viewer/2022081511/559515481a28abe9748b46c6/html5/thumbnails/13.jpg)
Leak Detection TrialAccuracy o Detect low flows 5-10L/min
![Page 14: NuRON - Water Network Monitoring & Leak Detection](https://reader035.fdocuments.in/reader035/viewer/2022081511/559515481a28abe9748b46c6/html5/thumbnails/14.jpg)
Leak Detection TrialMNFo Trends
Per Property Basis
![Page 15: NuRON - Water Network Monitoring & Leak Detection](https://reader035.fdocuments.in/reader035/viewer/2022081511/559515481a28abe9748b46c6/html5/thumbnails/15.jpg)
Conclusiono Increased monitoring using low-powered
micro processing equipment in the field.o More data opens up new ways of
operating and designing networkso Potential to impact many business units