302 atw Vol. 59 (2014) Issue 5 | May Nuclear Safety: LOCA Testing at the INKA Test Facility Passive BWR Integral LOCA Testing at the Karlstein Test Facility INKA Robert Drescher, Erlangen/Germany, Thomas Wagner, Karlstein am Main/Germany, and Stephan Leyer, Deggendorf/Germany Addresses of the authors: Robert Drescher AREVA GmbH Paul-Gossen-Straße. 100 91052 Erlangen, Germany Thomas Wagner AREVA GmbH Seligenstädter Straße 100 63791 Karlstein am Main, Germany Stephan Leyer TH University of Applied Sciences 94469 Deggendorf, Germany I. Introduction KERENA is a medium-capacity boiling wa- ter reactor developed by AREVA GmbH in cooperation with E.ON Kernkraft GmbH. It combines innovative passive systems with active systems of service-proven design. The passive systems utilize basic physical laws, such as gravity, pressure differences or heat transfer enabling these systems to function without electrical power supply or actuation by powered instruments and control (I&C) systems. They are designed to transfer the plant to a safe and stable state without the help of active systems. Furthermore the passive safety features partially replace the active systems which leads to a significant cost reduction and provides a reliable, safe and economically competitive plant design [Ref. 1]. The key elements of the KERENA pas- sive safety features are the Emergency Condenser (EC), the Containment Cooling Condenser (CCC) and the passive core flooding system. For the experimental vali- dation of the functionality of these systems Areva has carried out a test program at the test facility INKA [Ref. 2] (INKA: Integral Test Facility Karlstein). The test set-up al- lows testing of the single components indi- vidually to determine the performance characteristics of the systems. The tests were carried out in a full scale set-up, meaning that all components, levels and piping systems are available at the test fa- cility in a 1 by 1 realization compared to the KERENA design. The results of the tests have been published in several papers. Furthermore INKA is capable to per- form integral system tests simulating acci- dent scenarios under plant like conditions. The pressure vessel of the test facility is represented by the steam accumulator of the Karlstein Large Valve test facility GAP. This vessel is designed for operating pres- sures up to 160 bar and is fed by a Benson boiler with a maximum power output of 22 MW. It has a storage capacity of roughly 1/6 of the KERENA Reactor Pressure Ves- sel (RPV). The INKA test facility consists of 3 large scaled vessels representing the compartments of the KERENA contain- ment as well as a large water volume rep- resenting the SSP (called Shielding Stor- age Pool). The volumes are scaled down by a factor of 1/24, while the real plant height level differences are realized. The test fa- cility infrastructure allows running acci- dent scenarios. Starting from initial condi- tions derived from Boiling Water Reactor (BWR) operation conditions (e.g. RPV pressures of 70 bar and saturation condi- tions). Therefore no further test precondi- tioning based on numerical calculation re- sults is necessary. The goal of the tests is to determine the interaction of the systems as well as the re- sponse of the safety features including the pressure suppression containment to the accident scenario. Thus the ability of the passive safety systems to achieve all safety goals shall be demonstrated. The paper is divided into 3 parts. Sec- tion II describes the philosophy of the tests. Section III gives an overview of the test set-up and the instrumentation con- cept. Section IV explains the test perfor- mance and shows the test results. II. Goals of the test program The philosophy of the INKA test program is a combination of full scale component test- ing and validation of numerical tools used for accident analysis. The designers of pas- sive systems are challenged by the small driving force passive systems rely on and by the strong link between heat transfer and mass flow, as far as heat removal systems are concerned. Furthermore state of the art models (e.g. for heat transfer) are not nec- essarily applicable to passively driven sys- tems due to low driving forces. Therefore a full scale system set-up was chosen for the tests. Consequently mismatches between the experimentally determined data and the numerical calculation results have been identified [Ref. 3]. Especially for the low pressure heat transfer system CCC, instable operation conditions have been observed that are predictable by numerical code sys- tems only to a limited extents [Ref. 4]. Therefore test programs were launched to overcome the modelling deficits. The R&D program “Condensation in a Horizontal Heat Exchanger tube addresses the heat transfer modelling of passively driven heat transfer system. The project is carried out in the frame of a consortium between Areva GmbH, ETH Zürich and the HZDR (Helm- holtz Zentrum Dresden-Rossendorf). Fur- thermore the GENEVA Project deals with the stabilization of low pressure 2-phase flow systems. This project is executed at the Technische Universität Dresden in Coopera- tion with E.ON Kernkraft GmbH, HZDR and Areva GmbH. Passive systems interact and influence each other in their performance. E.g. the gravity driven injection is a function of the containment pressure and therefore de- pends on the performance of the Contain- ment Cooling Condensers. This example demonstrates the necessity to perform inte- gral system tests including all relevant pas- sive safety systems – passive residual heat re- moval and depressurization systems as well as passive core flooding. INKA is equipped with a complete train of those systems taken from the KERENA design. INKA allows simu- lating all anticipated design basis accidents – Loss-Of-Coolant-Accidents and non-LOCA – for real plant like conditions. This paper deals with the first per- formed accident simulation on the INKA test rig. The chosen scenario was the rup- ture of a main steam line. Due to the fact, that only passive systems are involved the only active measures dur- ing the test execution were the initiation of the leak mass flow and the simulation of the decay heat in the pressure vessel via

Transcript of Nuclear Safety: LOCA Testing at the INKA Test Facility ... · Nuclear Safety: LOCA Testing at the...

Page 1: Nuclear Safety: LOCA Testing at the INKA Test Facility ... · Nuclear Safety: LOCA Testing at the INKA Test Facility steam supply by the Benson boiler system. The accident simulation

302 atw Vol. 59 (2014) Issue 5 | May

Nuclear Safety: LOCA Testing at the INKA Test Facility

Passive BWR Integral LOCA Testing at the Karlstein Test Facility INKARobert Drescher, Erlangen/Germany, Thomas Wagner, Karlstein am Main/Germany, and Stephan Leyer, Deggendorf/Germany

Addresses of the authors:Robert Drescher

AREVA GmbHPaul-Gossen-Straße. 100

91052 Erlangen, Germany

Thomas WagnerAREVA GmbH

Seligenstädter Straße 10063791 Karlstein am Main, Germany

Stephan LeyerTH University of Applied Sciences

94469 Deggendorf, Germany

I. Introduction

KERENA is a medium-capacity boiling wa-ter reactor developed by AREVA GmbH in cooperation with E.ON Kernkraft GmbH. It combines innovative passive systems with active systems of service-proven design. The passive systems utilize basic physical laws, such as gravity, pressure differences or heat transfer enabling these systems to function without electrical power supply or actuation by powered instruments and control (I&C) systems. They are designed to transfer the plant to a safe and stable state without the help of active systems. Furthermore the passive safety features partially replace the active systems which leads to a significant cost reduction and provides a reliable, safe and economically competitive plant design [Ref. 1].

The key elements of the KERENA pas-sive safety features are the Emergency Condenser (EC), the Containment Cooling Condenser (CCC) and the passive core flooding system. For the experimental vali-dation of the functionality of these systems Areva has carried out a test program at the test facility INKA [Ref. 2] (INKA: Integral Test Facility Karlstein). The test set-up al-

lows testing of the single components indi-vidually to determine the performance characteristics of the systems. The tests were carried out in a full scale set-up, meaning that all components, levels and piping systems are available at the test fa-cility in a 1 by 1 realization compared to the KERENA design. The results of the tests have been published in several papers.

Furthermore INKA is capable to per-form integral system tests simulating acci-dent scenarios under plant like conditions. The pressure vessel of the test facility is represented by the steam accumulator of the Karlstein Large Valve test facility GAP. This vessel is designed for operating pres-sures up to 160 bar and is fed by a Benson boiler with a maximum power output of 22 MW. It has a storage capacity of roughly 1/6 of the KERENA Reactor Pressure Ves-sel (RPV). The INKA test facility consists of 3 large scaled vessels representing the compartments of the KERENA contain-ment as well as a large water volume rep-resenting the SSP (called Shielding Stor-age Pool). The volumes are scaled down by a factor of 1/24, while the real plant height level differences are realized. The test fa-cility infrastructure allows running acci-dent scenarios. Starting from initial condi-tions derived from Boiling Water Reactor (BWR) operation conditions (e.g. RPV pressures of 70 bar and saturation condi-tions). Therefore no further test precondi-tioning based on numerical calculation re-sults is necessary.

The goal of the tests is to determine the interaction of the systems as well as the re-sponse of the safety features including the pressure suppression containment to the accident scenario. Thus the ability of the passive safety systems to achieve all safety goals shall be demonstrated.

The paper is divided into 3 parts. Sec-tion II describes the philosophy of the tests. Section III gives an overview of the test set-up and the instrumentation con-

cept. Section IV explains the test perfor-mance and shows the test results.

II. Goals of the test program

The philosophy of the INKA test program is a combination of full scale component test-ing and validation of numerical tools used for accident analysis. The designers of pas-sive systems are challenged by the small driving force passive systems rely on and by the strong link between heat transfer and mass flow, as far as heat removal systems are concerned. Furthermore state of the art models (e.g. for heat transfer) are not nec-essarily applicable to passively driven sys-tems due to low driving forces. Therefore a full scale system set-up was chosen for the tests. Consequently mismatches between the experimentally determined data and the numerical calculation results have been identified [Ref. 3]. Especially for the low pressure heat transfer system CCC, instable operation conditions have been observed that are predictable by numerical code sys-tems only to a limited extents [Ref.  4]. Therefore test programs were launched to overcome the modelling deficits. The R&D program “Condensation in a Horizontal Heat Exchanger tube addresses the heat transfer modelling of passively driven heat transfer system. The project is carried out in the frame of a consortium between Areva GmbH, ETH Zürich and the HZDR (Helm-holtz Zentrum Dresden-Rossendorf). Fur-thermore the GENEVA Project deals with the stabilization of low pressure 2-phase flow systems. This project is executed at the Technische Universität Dresden in Coopera-tion with E.ON Kernkraft GmbH, HZDR and Areva GmbH.

Passive systems interact and influence each other in their performance. E.g. the gravity driven injection is a function of the containment pressure and therefore de-pends on the performance of the Contain-ment Cooling Condensers. This example demonstrates the necessity to perform inte-gral system tests including all relevant pas-sive safety systems – passive residual heat re-moval and depressurization systems as well as passive core flooding. INKA is equipped with a complete train of those systems taken from the KERENA design. INKA allows simu-lating all anticipated design basis accidents – Loss-Of-Coolant-Accidents and non-LOCA – for real plant like conditions.

This paper deals with the first per-formed accident simulation on the INKA test rig. The chosen scenario was the rup-ture of a main steam line.

Due to the fact, that only passive systems are involved the only active measures dur-ing the test execution were the initiation of the leak mass flow and the simulation of the  decay heat in the pressure vessel via

Page 2: Nuclear Safety: LOCA Testing at the INKA Test Facility ... · Nuclear Safety: LOCA Testing at the INKA Test Facility steam supply by the Benson boiler system. The accident simulation

303atw Vol. 59 (2014) Issue 5 | May

Nuclear Safety: LOCA Testing at the INKA Test Facility

steam supply by the Benson boiler system. The accident simulation was started from normal BWR conditions (pressure of 75 bar and temperature of 292 °C in the pressure vessel).

III. Test set-up

INKA was erected at Karlstein, Germany, in 2008. Figure 1 shows pictures of the test fa-cility taken from 2 different views. A de-tailed description of the test facility is giv-en in [Ref. 2].

INKA simulates the KERENA contain-ment in a volume scaling of 1:24. Figure 2 shows a comparison between the KERENA containment and the INKA test facility.

The Flooding Pool Vessel (FPV, green) simulates the 4 KERENA Flooding Pools containing the passive safety systems. The residual gas volume of the drywell is repre-sented by the drywell vessel (DWV, red). Two pipes connect the FPV with the DWV to represent the connections between the gas filled headspaces of these compart-ments. The wetwell function is provided by the Pressure Suppression Pool Vessel (PSPV, black).

The RPV is simulated by the steam accu-mulator vessel of the Large Valve Test Facil-ity GAP (GAP: Großarmaturen Prüfstand). It has a storage volume of 125 m3 and is fed by a Benson boiler with a maximum power supply of 22 MW. All components• the Emergency Condenser, EC,

• the Containment Cooling Condenser, CCC,

• the Passive Core Flooding Valve• as well as the level differences that are

important for the function of the pas-sive components are realized like in the real plant.

For the integral test all components and vessels are operated.

Figure 3 shows the piping between the vessels. The FPV is connected to the PSPV via the overflow pipe limiting the FPV wa-ter level. A second connection is the hydro-gen overflow pipe used for pressure limita-tion during severe accident mitigation at KERENA. The third connection is the Pas-sive Core Flooding Line with the Passive Core Flooding Valve which connects the FPV with the EC return line. The DWV and the PSPV are connected via a full scale vent pipe. Additionally, the function of the Safe-ty and Relief valve is included in the de-sign, discharging steam form the pressure vessel into the water inventory of the FPV. For LOCA test scenarios 2 different lines enter the DWV – one for the simulation of breaks of a water line, the other for breaks of a steam line (red lines).

III.A. Instrumentation

There are more than 300 sensors availa-ble at INKA. Most of them are standard in-strumentation like temperature, mass flow, pressure and differential pressure sensors.

Additionally 2-phase flow instrumenta-tion (Thermo Pin Probes and Gamma den-sitometer) developed in cooperation with HZDR are installed.

The gas mixture in the vessels is meas-ured by a mass spectrometer with a probe sampling system (Cooperation with Paul Scherrer Institut in Switzerland).

Figure 4 gives an overview of the sen-sors installed at the INKA test facility. The FPV has the highest sensor density due to the fact that this vessel contains the pas-sive systems EC and CCC.

Basically, in all vessels the pressures, the temperatures in the water and gas vol-umes and the water levels are measured.

In the main pipings (break line, EC inlet line, S+R line etc.) the mass flows are measured (CF).

During the tests global parameters as well as calculated values, e.g. EC power, mass flow, water level or decay heat simu-lation can be observed online (Figure 5).

IV. Test performance and results

IV.A. Test performance

Initially the vessels were filled with cold demineralized water produced by the

Fig. 1. View on INKA from west (left) and east (right).

INKA Test Facility KERENA

Shielding/storage pool

Corefloodingpool

Drywell

Pressuresuppressionchamber

RPV

Fig. 2. Comparison between the KERENA Containment and the INKA test facility.

Page 3: Nuclear Safety: LOCA Testing at the INKA Test Facility ... · Nuclear Safety: LOCA Testing at the INKA Test Facility steam supply by the Benson boiler system. The accident simulation

304 atw Vol. 59 (2014) Issue 5 | May

Nuclear Safety: LOCA Testing at the INKA Test Facility

water treatment plant of the Karlstein in-frastructure.

The Flooding Pool Vessel (FPV), the Pressure Suppression Pool Vessel (PSPV) and the Shielding/Storage Pool Vessel (SSPV) were filled to the dedicated water levels. The GAP vessel, simulating the RPV, was filled with water, too, but additionally heated up to the RPV conditions of 76 bar, saturation condition (see also Figure 6). The heating-up was performed by inject-ing steam from the steam generator into the RPV simulator.

At INKA, downstream of the EC an iso-lation valve is installed to “deactivate” the EC. This valve is only present at INKA due to the fact that the EC was designed for 66  MW and the Karlstein infrastructure “only” provides 22  MW. This valve was closed during the heating-up of the prima-ry system and opened shortly before the start of the test.

When the levels where balanced, the in-tegral test was started by opening the LOCA-simulation line. Then, the test facili-ty was left to its own devices.

Simulation of decay heat:The injection of steam into the RPV contin-ued in order to simulate decay heat. Since not only heat was injected, but also mass, this mass had to be released. In the bottom of the RPV-simulator a valve was con-trolled in order to release the mass which was added by the steam injection.

IV.B. Test results

Figure 6 shows the pressures in the pres-sure vessel and the compartment of the IN-KA containment as function of time.

The RPV pressure (red line) decreased due to the opening of the LOCA-simulation line. At the same time the Drywell (green line) and Flooding Pool (black line) pres-sures increased rapidly. The wetwell pres-sure followed simultaneously, but lower due to the water level covering the outlet of the vent pipe in the PSPV.

At approx. 1,250 seconds the contain-ment pressure (green and black line) reached its maximum value of approx. 3.3 bar, which is significantly lower than the design pressure of 4 bar. Shortly be-fore, the CCC started its operation.

The CCC is operating with an oscillating mass flow which is typical for low pressure systems (see Figure 7), that was already de-termined within the CCC single component test campaign [Ref. 4 and 5]. The oscilla-tions in the heat transfer are also recog-nized in minor containment pressure oscil-lations. The EC starts triggered by the de-creasing water level. Its heat transfer sup-ports the depressurization of the pressure vessel. After approximately 800 seconds

Steam inlet

RRV

SSPV

FPVcooling

PSPVcooling

FPV

DWVPSPV

Water outletWater outlet

Main heatsink

DWV: Drywell vesselFPV: Flooding pool vesselRPV: Reactor pressure vesselSSPV: Shielding/storage pool vesselPSPV: Pressure supression pool vessel

Fig. 3. Simplified process diagram.

FPV

SSPV

DWV

PSPV

GAP

CCC

CCCL

DWCL

HOP

VP

PCFV

PFL

EC

ECCL

ECSL

LMFL

Steam Supply

SRVL

LMFL

CP

CPCP

CP

CL

CL

CL

CT

CL

CT

CT

CT

CL

CT

P

P

CL

CL

P

CT

CQ

CQ CQ

CP

CT

CL

CF

P

CQ

Pressure

Temperature

Water level

Mass flow

Gas concentration

Heat transfer capacity

(calculated )

CP

CF

CF

CF

CFCF

CF CF

CF

CF

SRVP

OP

CP

GAP

CL

CT

P

CF

CL

CT

ECSL

SRVL

ECCL

CF

P

CL

CT

CF

P

CL

CF

CT

CF

CP

SSPV

CCCL

CCC

FPV

SRV

CPCQ

EC

PFL

PCFV

LMFL

CF

DWCL

HOP

CF

CP

CQ

CL

CT

DMV

CF

VP CP

CL

CQ

CT

CF P

CL

OP

PSPV

CP

CT

CL

CF

CQ

P

Pressure

Temperature

Water level

Mass flow

Gas concentration

Heat transfer capacity

(calculated)

Steam supply

Fig. 4. Simplified P&ID of INKA.

Fig. 5. Online P&ID, showing real-time test data.

Page 4: Nuclear Safety: LOCA Testing at the INKA Test Facility ... · Nuclear Safety: LOCA Testing at the INKA Test Facility steam supply by the Benson boiler system. The accident simulation

305atw Vol. 59 (2014) Issue 5 | May

Nuclear Safety: LOCA Testing at the INKA Test Facility

the major part of the residual heat removal is done via the leak mass flow and the mass flow through the Safety and Relief valve line. Therefore the EC heat transfer capaci-ty is below the measuring tolerance.

Figure 8 shows the water levels in the RPV, the FPV and the wetwell. Due to the break flow, the mass flow through the Safety and Relief Valve and also due to the operation of the EC the water level in the Pressure Vessel decreased. This level in-creased again when the passive flooding started (at approx. 2,000 seconds). Until the beginning of the passive core flooding, the water level in the Flooding Pool Vessel is kept constant by the overflow pipe. After 2,000 seconds the water level decreases caused by the gravity driven replenishing of the pressure vessel [Ref. 6]. The water level in the PSPV (wetwell) increased by the injection of steam from the drywell via the vent pipe.

Figure 9 shows the gas temperatures as function of time in different compart-ments. The gas temperature in the pres-sure vessel follows the pressure in the ves-sel until 2,500 s after the initiation of the test, so that permanently saturation condi-tions are given. As mentioned above, the flooding started at around 2,000 seconds, thus the temperature curve of the water in-ventory of the RPV recognized a rapidly decreasing temperature at around 2,500 seconds.

At the same time the water temperature inside the FPV rises due to the EC heat transfer.

The pressure increase inside the DWV and in the gas volume of the FPV is caused by the steam from the leak injection and later on also from the Safety and Relief Valve. After the pressure difference be-tween drywell and wetwell reaches ap-proximately 0.3 bar the vent pipe is acti-vated, so that a steam gas mixture is dis-charged into the wetwell. The wetwell gas temperature rises earlier than the tem-perature of the water inventory, which is heated up by the steam condensation. Considering the gas volumes of the vessel and the wetwell pressure increase it can be estimated that roughly 99 % of the non-condensable gases located initially in the FPV and the DWV are discharged into the wetwell during the blow down.

The pressure oscillations indicated in the pressure curves can also be seen in the temperature readings of the Drywell Vessel.

IV.C. Interpretation of the test results

The initiation of the accident simulation by opening the break mass flow line and the EC closure valve caused a response of the passive safety systems. The coolant dis-charged into the containment activated

0 1,000 2,000 3,0000

10

20

30

40

50

60

70

80

0

1

2

3

4RP

V pr

essu

re in

bar

Cont

ainm

ent

pres

sure

in b

ar

GAP / pressure vesselFlooding pool vesselDrywell vesselWetwell vessel

Time in s

Fig. 6. Pressures as function of time.

0 1,000 2,000 3,0000

10

20

30

40

0

5

10

15

20

Q, E

C in

MW

Q, C

CC in

MW

Time in s

EC powerCCC power

Fig. 7. EC and CCC heat transfer capacity as function of time.

0 1,000 2,000 3,0000

5

10

15

20

Leve

l in

m(a

bs)

Time in s

GAP / pressure vesselFlooding pool vesselWetwell vessel

Begin of passive flooding

Fig. 8. Water levels.

Page 5: Nuclear Safety: LOCA Testing at the INKA Test Facility ... · Nuclear Safety: LOCA Testing at the INKA Test Facility steam supply by the Benson boiler system. The accident simulation

306 atw Vol. 59 (2014) Issue 5 | May

Nuclear Safety: LOCA Testing at the INKA Test Facility

the containment pressure suppression sys-tem so that steam and air is injected into the wetwell. The forced steam condensa-tion limits the containment pressure to a value sufficiently lower than the design value. Furthermore the discharged coolant caused a reduction of the pressure vessel water level activating the EC so that a fur-ther energy transfer path between the pressure vessel and the containment is opened transferring heat without addi-tional coolant loss. After reaching a low water level in the RPV the Safety and Re-lieve Valve is opened, this supporting the pressure relief process. As soon as the re-quired pressure difference is reached the valve in the passive core system opens, so that the pressure vessel replenishing pro-cess is started increasing the water level again and ensuring long-term core cool-ing. In the long term phase of the accident the residual heat is transferred to the main heat sink pool outside of the containment via the CCC.

The experimental results prove that the passive systems perform well in their inter-action and achieve all design goals – core cooling, containment pressure suppression and residual heat removal – with sufficient safety margins.

The test results were used to perform a validation of the numerical code systems used for the KERENA accident simulation. The currently achieved status is summa-rized in [Ref. 7]. Nevertheless deviations between experimental and calculation re-sults have been observed, especially con-cerning the performance of the passive systems. Further outcomes of the calcula-tions are that the predictability of the con-tainment pressure suppression system strongly depends on the nodalization of the containment compartments.

V. CONCLUSIONS

The test results showed the response of the KERENA passive safety systems to the ex-perimentally simulated accident scenario “Main Steam Line Break inside the Con-tainment”. The results confirmed the func-tionality of the passive systems experimen-tally derived from earlier single compo-nent testing. Furthermore the interaction among the systems as well as the interac-tion with the pressure vessel and the pres-sure suppression containment was proven. During the experimental accident progres-sion the design criteria of the test facility

0 1,000 2,000 3,0000

50

100

150

200

250

300

Tem

pera

ture

in °

C

Time in s

GAP / pressure vessel, down (water)Flooding pool vessel (water)Drywell vessel, up

Drywell vessel, downWetwell vessel, down (water)

Wetwell vessel, up (steam)

Fig. 9. Temperatures in different compartments.

and thus also of KERENA were met, so that all safety goals were achieved with suffi-cient margins. The test therefore proves that passive safety concepts are applicable for large Boiling Water Reactors.

Further experimental activities on oth-er accident scenarios like bottom head or feed water line leak should be performed including validation of numerical codes and used for the qualification of compo-nents and for licensing requirements issues.

References

[1] Stosic, Z.V., Brettschuh, W., Stoll, U.: Boil-ing water reactor with innovative safety concept: The Generation III+ SWR-1000, Nuclear Engineering and Design 238 (2008) 1863–1901.

[2] Leyer, S., and Wich, M.: The Integral Test Facility Karlstein, Science and Technolo-gy of Nuclear Installations, Hindawi, Ar-ticle ID 439374, 12 pages, 2012.

[3] Annalisa Manera, Horst-Michael Prasser, Stephan Leyer, 14th International Topical Meeting on Nuclear Reactor Thermohy-draulics (2011): Analysis of the Perfor-mance of the KERENA Emergency Con-denser

[4] Leyer, S., Maisberger, F., Lineva, N., Wag-ner, T., Doll, M., Herbst, V., Wich, M., Schäfer, H.: Full scaled tests of the KERE-NATM Containment Cooling Condenser at the INKA test facility, Ann. Meeting of Nucl. Techn. 2010

[5] Leyer, S., Maisberger, F., Herbst, V., Doll, M., Wich, M., Wagner, T.: Status of the full scale component testing of the KER-ENATM Emergency Condenser and Con-tainment Cooling Condenser, Proceed-ings of ICAPP ’10, San Diego, CA, USA, June 13-17, 2010

[6] Wagner, T., Wich, M., Doll, M., Leyer, S.: Full scale tests with the Passive Core Flooding System and the Emergency Condenser at the integral Test Stand Karlstein for KERENATM, Proceedings of ICAPP ’11, Nice, France, May 2-5, 2011

[7] Robert Drescher, Thomas Wagner, Horst-Michael Prasser, Stephan Leyer, Passive Integral LOCA Testing at Karlstein Test Facility INKA, Proceedings of ICAPP 2014, USA