NSN Zef

85
EF - Base Control Function Handling DN9813196 Issue 17-0 en 29/02/2008 # Nokia Siemens Networks 1 (85) BSC3153 Nokia GSM/EDGE BSS, Rel. BSS13, BSC and TCSM, Rel. S13, Product Documentation, v.1

description

NSN Zef. command outputs...............................................will help in many ways.................................................................................

Transcript of NSN Zef

Page 1: NSN Zef

EF - Base Control FunctionHandling

DN9813196Issue 17-0 en29/02/2008

# Nokia Siemens Networks 1 (85)

BSC3153Nokia GSM/EDGE BSS, Rel. BSS13, BSC andTCSM, Rel. S13, Product Documentation, v.1

Page 2: NSN Zef

The information in this document is subject to change without notice and describes only theproduct defined in the introduction of this documentation. This documentation is intended for theuse of Nokia Siemens Networks customers only for the purposes of the agreement under whichthe document is submitted, and no part of it may be used, reproduced, modified or transmitted inany form or means without the prior written permission of Nokia Siemens Networks. Thedocumentation has been prepared to be used by professional and properly trained personnel,and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomescustomer comments as part of the process of continuous development and improvement of thedocumentation.

The information or statements given in this documentation concerning the suitability, capacity, orperformance of the mentioned hardware or software products are given “as is” and all liabilityarising in connection with such hardware or software products shall be defined conclusively andfinally in a separate agreement between Nokia Siemens Networks and the customer. However,Nokia Siemens Networks has made all reasonable efforts to ensure that the instructionscontained in the document are adequate and free of material errors and omissions. NokiaSiemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues whichmay not be covered by the document.

Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NOEVENT WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THISDOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL,DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUTNOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESSOPPORTUNITY OR DATA, THAT MAYARISE FROM THE USE OF THIS DOCUMENT OR THEINFORMATION IN IT.

This documentation and the product it describes are considered protected by copyrights andother intellectual property rights according to the applicable laws.

The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark ofNokia Corporation. Siemens is a registered trademark of Siemens AG.

Other product names mentioned in this document may be trademarks of their respective owners,and they are mentioned for identification purposes only.

Copyright © Nokia Siemens Networks 2008. All rights reserved.

2 (85) # Nokia Siemens Networks DN9813196Issue 17-0 en

29/02/2008

EF - Base Control Function Handling

Page 3: NSN Zef

Contents

Contents 3

List of tables 4

List of figures 5

Summary of changes 7

EF - BASE CONTROL FUNCTION HANDLING 11

EFC CREATE BASE CONTROL FUNCTION 13

EFD DELETE BASE CONTROL FUNCTION 29

EFM MODIFY BASE CONTROL FUNCTION PARAMETERS 31

EFO OUTPUT BASE CONTROL FUNCTION PARAMETERS 47

EFL OUTPUT BASE CONTROL FUNCTION SYNCHRONIZATIONCONFIGURATION 61

EFS CHANGE BASE CONTROL FUNCTION ADMINISTRATIVESTATE 69

EFT SET BASE CONTROL FUNCTION OUTPUTS 71

EFX SET BASE CONTROL FUNCTION EXTERNAL INPUTPARAMETERS 75

EFR RESET BASE CONTROL FUNCTION 79

EFE MODIFY EXTERNAL INPUT AND OUTPUT TEXT 81

EFP OUTPUT EXTERNAL INPUT AND OUTPUT TEXTS 83

DN9813196Issue 17-0 en29/02/2008

# Nokia Siemens Networks 3 (85)

Contents

Page 4: NSN Zef

List of tables

4 (85) # Nokia Siemens Networks DN9813196Issue 17-0 en

29/02/2008

EF - Base Control Function Handling

Page 5: NSN Zef

List of figures

DN9813196Issue 17-0 en29/02/2008

# Nokia Siemens Networks 5 (85)

List of figures

Page 6: NSN Zef

6 (85) # Nokia Siemens Networks DN9813196Issue 17-0 en

29/02/2008

EF - Base Control Function Handling

Page 7: NSN Zef

Summary of changes

Changes between document issues are cumulative. Therefore, the latestdocument issue contains all changes made to previous issues.

Changes made between issues 17-0 and 16-1

EFC CREATE BASE CONTROL FUNCTION

New parameters automatic unlock allowed (AU), TRXshutdown timer 2 (NTIM2), TRX shutdown timer 3(NTIM3), Flexi EDGE Abis over IP Ethernet usage(TRS1), Flexi EDGE Additional 2 E1/T1 usage(TRS2), Flexi EDGE TRS Abis Grooming usage(TRS3), and Flexi EDGE TRS Loop Protection usage(TRS4) have been added, and the parameterexplanations, syntax, and execution printout 4 havebeen updated accordingly.

Parameter explanations of TRX shutdown timer(NTIM) and BCCH TRX shutdown timer (BTIM) havebeen updated.

A new execution printout has been added for NokiaFlexi EDGE site type.

EFM MODIFY BASE CONTROL FUNCTIONPARAMETERS

New parameters automatic unlock allowed (AU), TRXshutdown timer 2 (NTIM2), TRX shutdown timer 3(NTIM3), Flexi EDGE Abis over IP Ethernet usage(TRS1), Flexi EDGE Additional 2 E1/T1 usage(TRS2), Flexi EDGE TRS Abis Grooming usage(TRS3), and Flexi EDGE TRS Loop Protection usage(TRS4) have been added, and the parameterexplanations and syntax have been updatedaccordingly.

DN9813196Issue 17-0 en29/02/2008

# Nokia Siemens Networks 7 (85)

Summary of changes

Page 8: NSN Zef

Parameter explanations of TRX shutdown timer(NTIM) and BCCH TRX shutdown timer (BTIM) havebeen updated.

Execution printouts for Nokia MetroSite and NokiaUltraSite site types have been updated.

EFO OUTPUT BASE CONTROL FUNCTIONPARAMETERS

Command example 1 has been updated.

Execution printout for Nokia UltraSite has beenupdated and execution printouts for Nokia FlexiEDGE site type have been added. Also the executionprintout abbreviations section has been updated.

Description of abbreviation BL-SWO has beenupdated, and abbreviations BL-CF, BL-CU, and BL-FU have been removed.

EFL OUTPUT BASE CONTROL FUNCTIONSYNCHRONIZATION CONFIGURATION

The execution printout abbreviations section hasbeen updated.

Description of abbreviation BL-SWO has beenupdated, and abbreviations BL-CF, BL-CU, and BL-FU have been removed.

Changes made between issues 16-1 and 16-0

EFC CREATE BASE CONTROL FUNCTION

Flexi EDGE optionality was added to the site typeparameter values.

EFM MODIFY BASE CONTROL FUNCTIONPARAMETERS

Flexi EDGE optionality was added to the site typeparameter values.

Changes made between issues 16-0 and 15-2

Editorial changes.

EFC CREATE BASE CONTROL FUNCTION

ABIS SYNCH and LMU SYNCH were added to theparameter explanation of synchronization mode.

8 (85) # Nokia Siemens Networks DN9813196Issue 17-0 en

29/02/2008

EF - Base Control Function Handling

Page 9: NSN Zef

Connect type parameter was removed.

Flexi EDGE information was added.

EFD DELETE BASE CONTROL FUNCTION

A mention of TRE was added.

EFM MODIFY BASE CONTROL FUNCTIONPARAMETERS

Connect type parameter was removed.

Flexi EDGE information was added.

EFO OUTPUT BASE CONTROL FUNCTIONPARAMETERS

Connect type parameter was removed.

Reference to Automatic Picocell Planning wasremoved.

ABIS SYNCH and LMU SYNCH were added to theexecution printout abbreviations.

The first execution printout was updated.

EFL OUTPUT BASE CONTROL FUNCTIONSYNCHRONIZATION CONFIGURATION

Reference to Automatic Picocell Planning wasremoved.

EFE MODIFY EXTERNAL INPUT AND OUTPUT TEXT

Parameter description of text string was updated.

EFX SET BASE CONTROL FUNCTION EXTERNALINPUT PARAMETERS

Flexi EDGE information was added.

EFR RESET BASE CONTROL FUNCTION

Flexi EDGE information was added.

DN9813196Issue 17-0 en29/02/2008

# Nokia Siemens Networks 9 (85)

Summary of changes

Page 10: NSN Zef

10 (85) # Nokia Siemens Networks DN9813196Issue 17-0 en

29/02/2008

EF - Base Control Function Handling

Page 11: NSN Zef

EF - BASE CONTROL FUNCTION HANDLING

With the commands of the EF command group you can create and deletea BCF object. In addition, you can change and output the parameters, theadministrative state of the BCF object and the states of the externaloutputs in the BSS Radio Network Configuration Database (BSDATA). Youcan also reset the BTS site or its Operation and Maintenance Unit (OMU).

In addition, with the commands of this command group you can attach atext string to external inputs and outputs of the BCF and modify the textstring. You can also set external input parameters of the BCF.

Menu of the command group:

BASE CONTROL FUNCTION HANDLING COMMANDS

? ..... DISPLAY MENU

C: ..... CREATE BASE CONTROL FUNCTION

D: ..... DELETE BASE CONTROL FUNCTION

M: ..... MODIFY BASE CONTROL FUNCTION PARAMETERS

O: ..... OUTPUT BASE CONTROL FUNCTION PARAMETERS

L: ..... OUTPUT BASE CONTROL FUNCTION SYNCHRONIZATION CONFIGURATION

S: ..... CHANGE BASE CONTROL FUNCTION ADMINISTRATIVE STATE

T: ..... SET BASE CONTROL FUNCTION OUTPUTS

X: ..... SET BASE CONTROL FUNCTION EXTERNAL INPUT PARAMETERS

R: ..... RESET BASE CONTROL FUNCTION

E: ..... MODIFY EXTERNAL INPUT AND OUTPUT TEXT

P: ..... OUTPUT EXTERNAL INPUT AND OUTPUT TEXTS

Z; ..... RETURN TO MAIN LEVEL

DN9813196Issue 17-0 en29/02/2008

# Nokia Siemens Networks 11 (85)

EF - BASE CONTROL FUNCTION HANDLING

Page 12: NSN Zef

12 (85) # Nokia Siemens Networks DN9813196Issue 17-0 en

29/02/2008

EF - Base Control Function Handling

Page 13: NSN Zef

EFC CREATE BASE CONTROL FUNCTIONFunction With this command you create a BCF object in the BSS Radio Network

Configuration Database (BSDATA).

Parameters BCF identification, site type: autoconfigure <option>, bit rate <option>,automatic unlock allowed, D-channel link set number, D-channel link setname, reference BCF identification, RX difference limit: identification oftest equipment: BTS battery backup procedure <option>, TRX shutdowntimer <option>, TRX shutdown timer 2 <option>, TRX shutdown timer 3<option>, BCCH TRX shutdown timer <option>: clock source, add BCF tochain, synch enabled, master clock BCF identification: Flexi EDGE Abisover IP Ethernet usage <option>, Flexi EDGE Additional 2 E1/T1 usage<option>, Flexi EDGE TRS Abis Grooming usage <option>, Flexi EDGETRS Loop Protection usage <option>;

Syntax

EFC: <BCF identification>,

<site type> :

[ AC = <autoconfigure> <option> | N def |

BR = <bit rate> <option> |

AU = <automatic unlock allowed> | T def |

DNBR = <D-channel link set number> |

DNAME = <D-channel link set name> |

REF = <reference BCF identification> |

RXDL = <RX difference limit> | 10 def | ] ... :

[ TEST = <identification of test equipment> | NOT def ] :

[ BBU = <BTS battery backup procedure> | ALL def |

NTIM = <TRX shutdown timer> | 0 def |

NTIM2 = <TRX shutdown timer 2> <option> | 0 def |

NTIM3 = <TRX shutdown timer 3> <option> | 0 def |

BTIM = <BCCH TRX shutdown timer> | 0 def ] ... <option> :

[[ CS = <clock source> | NOT USED def |

ADD = <add BCF to chain> ... |

SENA = <synch enabled> | F def ] ... |

DN9813196Issue 17-0 en29/02/2008

# Nokia Siemens Networks 13 (85)

EFC CREATE BASE CONTROL FUNCTION

Page 14: NSN Zef

[ MCBCF = <master clock BCF identification> ]] :

[ TRS1 = <Flexi EDGE Abis over IP Ethernet usage> <option> | 0 def |

TRS2 = <Flexi EDGE Additional 2 E1/T1 usage> <option> | 0 def |

TRS3 = <Flexi EDGE TRS Abis Grooming usage> <option> | 0 def |

TRS4 = <Flexi EDGE TRS Loop Protection usage> <option> | 0 def ] ... ;

Parameterexplanations

BCF identification

With this parameter you identify the BCF with a decimal number. The valuerange depends on the BSC hardware configuration and the correspondingoptions.

The parameter is obligatory.

site type

With this parameter you identify the type of the BTS site. The alternativesare:

B: Nokia 2nd generation

D: Nokia Talk-family

F: Nokia PrimeSite

C: Nokia MetroSite

I: Nokia InSite

P: Nokia UltraSite

E: <option> Nokia Flexi EDGE

The parameter is obligatory.

autoconfigure <option>

With this parameter you define whether the BCF is created to beautoconfigured.

The values are:

Parameter Value Explanation

AC = Y BCF is created to beautoconfigured.

N BCF is not created to beautoconfigured.

14 (85) # Nokia Siemens Networks DN9813196Issue 17-0 en

29/02/2008

EF - Base Control Function Handling

Page 15: NSN Zef

You can give this parameter only if the site type is Nokia MetroSite, NokiaInSite, Nokia UltraSite, or Nokia Flexi EDGE.

The default value is N.

automatic unlock allowed

With this parameter you define whether the automatic unlock is allowed forthe BCF or not.

The values are:

Parameter Value Explanation

AU = T Automatic unlock isallowed.

F Automatic unlock is notallowed.

The default value is T.

You can give this parameter only if the site type is Nokia Flexi EDGE.

bit rate <option>

BR = decimal number

With this parameter you define the bit rate of the D-channel O&M signallinglink of the BCF.

The values are 8, 16, 32, or 64 kbps.

This parameter is obligatory if the BCF is created to be autoconfigured (thevalue of parameter autoconfigure is Y).

If the BCF is not created to be autoconfigured, you cannot give thisparameter.

D-channel link set number

DNBR = decimal number

With this parameter you identify the D-channel link set number of the BTSsite O&M link. You can give only one of the parameters DNBR and DNAMEin the same command.

DN9813196Issue 17-0 en29/02/2008

# Nokia Siemens Networks 15 (85)

EFC CREATE BASE CONTROL FUNCTION

Page 16: NSN Zef

You cannot give the D-channel link set number for the Nokia PrimeSite.

You cannot give this parameter if the BCF is created to be autoconfigured.

D-channel link set name

DNAME = text string

With this parameter you identify the D-channel link set name of the BTSsite O&M link. The name can contain 1 to 5 characters. You can give onlyone of the parameters DNBR and DNAME in the same command.

You cannot give the D-channel link set name for the Nokia PrimeSite.

This parameter is obligatory if the BCF is created to be autoconfigured (thevalue of parameter autoconfigure is Y).

If the BCF is created to be autoconfigured, the D-channel O&M signallinglink cannot exist because it is created during the BCF creation.

reference BCF identification

REF = decimal number

With this parameter you identify the BCF that is used to obtain the externalinput and output values. The value range depends on the BSC hardwareconfiguration and the corresponding options.

If a reference BCF is not used, the system uses the default values for therequired BCF parameters during the creation.

The parameter is allowed only for the Nokia MetroSite, Nokia UltraSite,and Nokia Flexi EDGE site types.

RX difference limit

RXDL = decimal number

With this parameter you define the value limit for activating the RX alarm.The BTS compares the main and diversity antenna RX levels and if thedifference is below this limit, an RX alarm is set.

The values range from 3 to 64 dB.

The default value is 10 dB.

16 (85) # Nokia Siemens Networks DN9813196Issue 17-0 en

29/02/2008

EF - Base Control Function Handling

Page 17: NSN Zef

For site types Nokia UltraSite, Nokia MetroSite, Nokia 2nd generation, andNokia Flexi EDGE the value 64 dB indicates that no RX alarms are set.

The parameter is not available for the Nokia InSite site type.

identification of test equipment

With this parameter you define the test equipment connected to the BCF.The values are:

Parameter Value Explanation

TEST = STM Site Test Monitor unit

RFTE Radio Frequency TestEquipment

NOT no test equipment

The default value is that no test equipment is connected to the BCF.

Value RFTE is allowed only for the Nokia 2nd generation site type.

The parameter is available only for the Nokia 2nd generation and NokiaTalk-family site types.

BTS battery backup procedure <option>

With this parameter you define what type of BTS battery backup procedureis used. The procedure is executed when the mains power goes down atthe BTS site and there is a battery backup unit.

The values are:

Parameter Value Explanation

BBU = ALL Transmission equipmentand all the TRXs are leftalive.

BCCH Transmission equipmentand only the BCCH TRXare left alive.

NONE Only transmissionequipment is left alive.

The default value is that all the TRXs and transmission equipment are leftalive.

DN9813196Issue 17-0 en29/02/2008

# Nokia Siemens Networks 17 (85)

EFC CREATE BASE CONTROL FUNCTION

Page 18: NSN Zef

The parameter is not available for the Nokia PrimeSite or Nokia InSite sitetypes.

TRX shutdown timer <option>

NTIM = decimal number

With this parameter you define the time period after which shutdown group1 TRXs are powered down. The time starts after the TRX Shutdown Timer2 has expired. The parameter is valid only if the BTS Battery BackupProcedure (BBU) parameter has value BCCH or NONE.

The values range from 0 to 600 minutes. The default value is 0.

The parameter is not available for the Nokia PrimeSite or Nokia InSite sitetypes.

TRX shutdown timer 2 <option>

NTIM2 = decimal number

With this parameter you define the time period after which shutdown group2 TRXs are powered down. The time starts after the TRX Shutdown Timer3 has expired. The parameter is valid only if the BTS Battery BackupProcedure (BBU) parameter has value BCCH or NONE.

The values range from 0 to 600 minutes. The default value is 0.

The parameter is not available for the Nokia PrimeSite, Nokia InSite, orNokia 2nd generation site types.

TRX shutdown timer 3 <option>

NTIM3 = decimal number

With this parameter you define the time period after which shutdown group3 TRXs are powered down. The parameter is valid only if the BTSBattery Backup Procedure (BBU) parameter has value BCCH orNONE.

The values range from 0 to 600 minutes. The default value is 0.

The parameter is not available for the Nokia PrimeSite, Nokia InSite, orNokia 2nd generation site types.

BCCH TRX shutdown timer <option>

18 (85) # Nokia Siemens Networks DN9813196Issue 17-0 en

29/02/2008

EF - Base Control Function Handling

Page 19: NSN Zef

BTIM = decimal number

With this parameter you define the time period after which shutdown group0 TRXs are powered down. The time starts after the TRX Shutdown Timer1 has expired. The parameter is valid only if the BTS Battery BackupProcedure (BBU) parameter has value BCCH or NONE. Also the BCCHTRXs are powered down when the BTS Battery Backup Procedure(BBU) parameter has value NONE.

The values range from 0 to 600 minutes. The default value is 0.

The parameter is not available for the Nokia PrimeSite or Nokia InSite sitetypes.

clock source

With this parameter you define the clock source of the master clock BCF orthe independent mode BCF. When creating the master clock BCF, theclock source must be BCF, LMU, or LAB. Use LMU and LAB values whenBSS synchronisation is in use.

The values you can give are:

Parameter Value Explanation

CS = BCF master clock BCF

LMU Location Measurement Unit

LAB Location Measurement Unitwith Abis recovery (LMU-ABIS)

NONE remove clock source

PCM independent mode

The default value is NOT USED.

The parameter is not available for the Nokia 2nd generation, NokiaPrimeSite, or Nokia InSite site types.

add BCF to chain

ADD = decimal number

DN9813196Issue 17-0 en29/02/2008

# Nokia Siemens Networks 19 (85)

EFC CREATE BASE CONTROL FUNCTION

Page 20: NSN Zef

With this parameter you define BCFs to a chain under the master clockBCF. The value range depends on the BSC hardware configuration andthe corresponding options. You can enter several values at the same timeby using the grouping character &. You can define at the most 8 BCFs to achain under the master clock BCF. The definition is done when creatingthe master clock BCF.

The parameter is not available for the Nokia 2nd generation, NokiaPrimeSite, or Nokia InSite site types.

synch enabled

With this parameter you enable the synchronisation of the BCF chain orthe independent mode BCF. The enabling of the synchronisation ispossible only when creating the master clock BCF or the independentmode BCF.

The values are:

Parameter Value Explanation

SENA = T Synchronisation enabled.

F Synchronisation disabled.

The default value is F.

The parameter is not available for the Nokia 2nd generation, NokiaPrimeSite, or Nokia InSite site types.

master clock BCF identification

MCBCF = decimal number

With this parameter you add the BCF to a chain. The value range dependson the BSC hardware configuration and the corresponding options. Thedefinition is done when creating the BCF which is added to a chain under amaster clock BCF.

The parameter is not available for the Nokia 2nd generation, NokiaPrimeSite, or Nokia InSite site types.

synchronization mode

SM (non-modifiable)

This parameter describes the synchronisation mode of the BCF.

20 (85) # Nokia Siemens Networks DN9813196Issue 17-0 en

29/02/2008

EF - Base Control Function Handling

Page 21: NSN Zef

The values are:

Parameter Value Explanation

SM = UNSYNCH unsynchronised

SYNCH synchronised

ABIS SYNCH BSS synchronised usingAbis

LMU SYNCH BSS synchronised usingLocation Measurement Unit

The value SYNCH is shown in printouts when the synchronisation of theBCF or the BCF chain is enabled and the BCF is working in thesynchronised mode.

Flexi EDGE Abis over IP Ethernet usage <option>

With this parameter you enable Flexi EDGE Abis over IP/ Ethernet in theBCF.

The values are:

Parameter Value Explanation

TRS1 = 0 Flexi EDGE Abis over IP/Ethernet not in use.

1 Flexi EDGE Abis over IP/Ethernet in use.

The default value is 0.

This parameter is valid only for Nokia Flexi EDGE site type.

Flexi EDGE Additional 2 E1/T1 usage <option>

With this parameter you enable Flexi EDGE Additional 2 E1/T1 in the BCF.

The values are:

Parameter Value Explanation

TRS2 = 0 2 E1/T1 free interfaces inuse.

1 Additional 2 E1/T1interface in use.

DN9813196Issue 17-0 en29/02/2008

# Nokia Siemens Networks 21 (85)

EFC CREATE BASE CONTROL FUNCTION

Page 22: NSN Zef

Parameter Value Explanation

2 2 additional 2 E1/T1interfaces in use.

3 3 additional 2 E1/T1interfaces in use.

The default value is 0.

This parameter is valid only for Nokia Flexi EDGE site type.

Flexi EDGE TRS Abis Grooming usage <option>

With this parameter you enable Flexi EDGE TRS Abis Grooming in theBCF.

The values are:

Parameter Value Explanation

TRS3 = 0 Flexi EDGE TRS AbisGrooming not in use.

1 Flexi EDGE TRS AbisGrooming in use.

The default value is 0.

This parameter is valid only for Nokia Flexi EDGE site type.

Flexi EDGE TRS Loop Protection usage <option>

With this parameter you enable Flexi EDGE TRS Loop Protection in theBCF.

The values are:

Parameter Value Explanation

TRS4 = 0 Flexi EDGE TRS LoopProtection not in use.

1 Flexi EDGE TRS LoopProtection in use.

The default value is 0.

This parameter is valid only for Nokia Flexi EDGE site type.

22 (85) # Nokia Siemens Networks DN9813196Issue 17-0 en

29/02/2008

EF - Base Control Function Handling

Page 23: NSN Zef

Examples 1. Create a BCF whose identification number is 127 and site type isNokia PrimeSite.

ZEFC:127,F;

2. Create a BCF whose identification number is 128, D-channel link setnumber is 5, and site type is Nokia 2nd generation.

ZEFC:128,B:DNBR=5;

3. Create a BCF whose identification number is 12, D-channel link setname is FU11, and site type is Nokia Talk-family. The test equipmentSTM is connected to it and no TRXs are left alive after timers haveexpired on the BTS battery backup procedure. The BCF is createdas an independent mode BCF and the synchronisation is enabled.

ZEFC:12,D:DNAME=FU11:TEST=STM:BBU=NONE,NTIM=30,BTIM=60:CS=PCM,SENA=T;

4. Create a BCF whose identification number is 120, D-channel link setname is AC1, and site type is Nokia MetroSite. The reference BCF-121 is used to obtain the external input and output parameters. TheBCF is created to be autoconfigured and the bit rate of the O&Msignalling link is set to 64 kbps. The BCF is created as the masterclock BCF and the clock source is defined to LMU. BCFs 121 and122 are added to the chain under the master clock BCF.

ZEFC:120,C:AC=Y,BR=64,DNAME=AC1,REF=121:::CS=LMU,ADD=121&122;

5. Create a BCF whose identification number is 125, D-channel link setname is AC2, and site type is Nokia UltraSite. The BCF is created tobe autoconfigured and the bit rate of the O&M signalling link is set to16 kbps. The BCF is added to the chain under the master clock BCFnumber 110.

ZEFC:125,P:AC=Y,BR=16,DNAME=AC2:::MCBCF=110;

Additionalinformation

After you have created a BCF its administrative state is LOCKED and itsexternal outputs are in the OFF state.

In addition, the default values are set for the BCF's external inputparameters. The default parameter values are:

PARAMETER ABBR. VALUE

master clock trx MCT 0 (not synchronised)

external synchronisation source ESS 2 (PCM external)

route ROU NOT (not reported)

polarity POL OPEN (open)

severity SEV AL1 (lowest alarm level)

text ID TID 0 (text not defined)

DN9813196Issue 17-0 en29/02/2008

# Nokia Siemens Networks 23 (85)

EFC CREATE BASE CONTROL FUNCTION

Page 24: NSN Zef

Executionprintouts

The printout of command example 1 is the following:

BSC BSC-LAB 2007-10-10 13:55:06

BASE CONTROL FUNCTION BCF-0127 CREATED

SITE TYPE ............................ F - PRIMESITE

ADMINISTRATIVE STATE ................. LOCKED

OPERATIONAL STATE .................... BL-USR

RX DIFFERENCE LIMIT ..........(RXDL).. 10 dB

MASTER CLOCK TRX .............(MCT)... 0 (NOT SYNCHRONISED)

EXTERNAL SYNC SOURCE .........(ESS)... 2 (PCM EXTERNAL)

DEFAULT BCF SOFTWARE BUILD ATTACHED

COMMAND EXECUTED

The printout of command example 2 is the following:

BSC BSC-LAB 2007-10-10 13:54:32

BASE CONTROL FUNCTION BCF-0128 CREATED

SITE TYPE ............................ B - 2ND GEN

ADMINISTRATIVE STATE ................. LOCKED

OPERATIONAL STATE .................... BL-USR

D-CHANNEL LINK SET 5 ............. FU2 WO-EX

OUTPUT 1 .......................... OFF

OUTPUT 2 .......................... OFF

OUTPUT 3 .......................... OFF

OUTPUT 4 .......................... OFF

OUTPUT 5 .......................... OFF

OUTPUT 6 .......................... OFF

RX DIFFERENCE LIMIT ..........(RXDL).. 10 dB

TEST EQUIPMENT ...............(TEST).. --

BTS BATTERY BACKUP PROCEDURE .(BBU)... ALL

TRX SHUTDOWN TIMER ...........(NTIM).. 0 min

BCCH TRX SHUTDOWN TIMER ......(BTIM).. 0 min

DEFAULT BCF SOFTWARE BUILD ATTACHED

COMMAND EXECUTED

The printout of command example 4 for MetroSite is the following:

BSC BSC-LAB 2007-10-10 14:14:32

BASE CONTROL FUNCTION BCF-0120 CREATED

BCF IS WAITING FOR AUTOCONFIGURATION

24 (85) # Nokia Siemens Networks DN9813196Issue 17-0 en

29/02/2008

EF - Base Control Function Handling

Page 25: NSN Zef

SITE TYPE ............................ C - METROSITE

ADMINISTRATIVE STATE ................. LOCKED

OPERATIONAL STATE .................... BL-USR

D-CHANNEL LINK SET 1 ............. AC1 BL-SY

OUTPUT 1 ....................... ON TEXT ID 2

ADDITIONAL COOLER FAN

OUTPUT 2 ........................ ON TEXT ID -

OUTPUT 3 ........................ OFF TEXT ID -

OUTPUT 4 ........................ OFF TEXT ID -

INPUT 1 ..............ROUTE: ACT

POLARITY: OPEN SEVERITY: *** TEXT ID 99

RECTIFIER MAJOR ALARM

INPUT 2 ..............ROUTE: NOT REPORT

POLARITY: OPEN SEVERITY: * TEXT ID -

INPUT 3 ..............ROUTE: NOT REPORT

POLARITY: OPEN SEVERITY: * TEXT ID -

INPUT 4 ..............ROUTE: NOT REPORT

POLARITY: OPEN SEVERITY: * TEXT ID -

INPUT 5 ..............ROUTE: NOT REPORT

POLARITY: OPEN SEVERITY: * TEXT ID -

INPUT 6 ..............ROUTE: NOT REPORT

POLARITY: OPEN SEVERITY: * TEXT ID -

INPUT 7 ..............ROUTE: NOT REPORT

POLARITY: OPEN SEVERITY: * TEXT ID -

INPUT 8 ..............ROUTE: NOT REPORT

POLARITY: OPEN SEVERITY: * TEXT ID -

INPUT 9 ..............ROUTE: NOT REPORT

POLARITY: OPEN SEVERITY: * TEXT ID -

INPUT 10 ..............ROUTE: NOT REPORT

POLARITY: OPEN SEVERITY: * TEXT ID -

RX DIFFERENCE LIMIT ..........(RXDL).. 10 dB

BTS BATTERY BACKUP PROCEDURE .(BBU)... ALL

TRX SHUTDOWN TIMER ...........(NTIM).. 0 min

TRX SHUTDOWN TIMER 2 .........(NTIM2). 0 min

TRX SHUTDOWN TIMER 3 .........(NTIM3). 0 min

BCCH TRX SHUTDOWN TIMER ......(BTIM).. 0 min

MASTER CLOCK BCF .............(MCBCF). 0120

CHAIN BCFS AFTER MASTER CLOCK BCF:

BCF-0121

BCF-0122

CLOCK SOURCE .................(CS).... LMU

SYNCHRONIZATION ENABLED ......(SENA).. F

SYNCHRONIZATION MODE .........(SM).... UNSYNCH

DEFAULT BCF SOFTWARE BUILD ATTACHED

COMMAND EXECUTED

The printout of command example 4 using site type E (Flexi EDGE) is thefollowing:

DN9813196Issue 17-0 en29/02/2008

# Nokia Siemens Networks 25 (85)

EFC CREATE BASE CONTROL FUNCTION

Page 26: NSN Zef

BSC BSC-LAB 2007-10-10 14:14:32

BASE CONTROL FUNCTION BCF-0120 CREATED

BCF IS WAITING FOR AUTOCONFIGURATION

SITE TYPE ............................ E - FLEXI EDGE

ADMINISTRATIVE STATE ................. LOCKED

OPERATIONAL STATE .................... BL-USR

D-CHANNEL LINK SET 1 ............. AC1 BL-SY

OUTPUT 1 ....................... ON TEXT ID 2

ADDITIONAL COOLER FAN

OUTPUT 2 ........................ ON TEXT ID -

OUTPUT 3 ........................ OFF TEXT ID -

OUTPUT 4 ........................ OFF TEXT ID -

INPUT 1 ..............ROUTE: ACT

POLARITY: OPEN SEVERITY: *** TEXT ID 99

RECTIFIER MAJOR ALARM

INPUT 2 ..............ROUTE: NOT REPORT

POLARITY: OPEN SEVERITY: * TEXT ID -

INPUT 3 ..............ROUTE: NOT REPORT

POLARITY: OPEN SEVERITY: * TEXT ID -

INPUT 4 ..............ROUTE: NOT REPORT

POLARITY: OPEN SEVERITY: * TEXT ID -

INPUT 5 ..............ROUTE: NOT REPORT

POLARITY: OPEN SEVERITY: * TEXT ID -

INPUT 6 ..............ROUTE: NOT REPORT

POLARITY: OPEN SEVERITY: * TEXT ID -

INPUT 7 ..............ROUTE: NOT REPORT

POLARITY: OPEN SEVERITY: * TEXT ID -

INPUT 8 ..............ROUTE: NOT REPORT

POLARITY: OPEN SEVERITY: * TEXT ID -

INPUT 9 ..............ROUTE: NOT REPORT

POLARITY: OPEN SEVERITY: * TEXT ID -

INPUT 10 ..............ROUTE: NOT REPORT

POLARITY: OPEN SEVERITY: * TEXT ID -

RX DIFFERENCE LIMIT ..........(RXDL).. 10 dB

BTS BATTERY BACKUP PROCEDURE .(BBU)... ALL

TRX SHUTDOWN TIMER ...........(NTIM).. 0 min

TRX SHUTDOWN TIMER 2 .........(NTIM2). 0 min

TRX SHUTDOWN TIMER 3 .........(NTIM3). 0 min

BCCH TRX SHUTDOWN TIMER ......(BTIM).. 0 min

MASTER CLOCK BCF .............(MCBCF). 0120

CHAIN BCFS AFTER MASTER CLOCK BCF:

BCF-0121

BCF-0122

CLOCK SOURCE .................(CS).... LMU

SYNCHRONIZATION ENABLED ......(SENA).. F

SYNCHRONIZATION MODE .........(SM).... UNSYNCH

AUTOMATIC UNLOCK ALLOWED .....(AU).... T

FACCH LAPDM T200 .............(T200F). 0 (BCF PREDEFINED VALUES)

SDCCH LAPDM T200 .............(T200S). 0 (BCF PREDEFINED VALUES)

ABIS OVER IP ETHERNET USAGE...(TRS1).. 0 (NOT IN USE)

ADDITIONAL 2 E1/T1 USAGE......(TRS2).. 0 (NOT IN USE)

26 (85) # Nokia Siemens Networks DN9813196Issue 17-0 en

29/02/2008

EF - Base Control Function Handling

Page 27: NSN Zef

TRS ABIS GROOMING USAGE.......(TRS3).. 0 (NOT IN USE)

TRS LOOP PROTECTION USAGE.....(TRS4).. 0 (NOT IN USE)

DEFAULT BCF SOFTWARE BUILD ATTACHED

COMMAND EXECUTED

Semantic errormessages

/*** BCF IS NOT DEFINED TO MASTER CLOCK BCF ***/

The BCF, which you have attempted to define as the master clock BCF ofthe created BCF, is not a master clock BCF.

/*** CHAIN BCF NOT FOUND IN BSC DATABASE ***/

The BCF, which you have attempted to add to the chain under the masterclock BCF, does not exist.

In addition, the general semantic error messages of the MML commandsare output. For more information, see General Notice Messages of MMLSession.

Execution errormessages

/*** ATTACHMENT OF DEFAULT BCF SOFTWARE BUILD FAILED ***/

The BCF creation was successful but attaching the software build failed.

/*** BCSU UPDATE ERROR ***/

The creation was successful but updating one or more BCSUs failed. Afterthis message, a list of failed BCSU updates is output, for example, in thefollowing form:

/*** BCSU-05 NOT UPDATED ***/

/*** BCSU-07 NOT UPDATED ***/

In addition, the general execution error messages of the MML commandsare used. For more information, see Radio Network Administration andGeneral Error Messages of System.

DN9813196Issue 17-0 en29/02/2008

# Nokia Siemens Networks 27 (85)

EFC CREATE BASE CONTROL FUNCTION

Page 28: NSN Zef

28 (85) # Nokia Siemens Networks DN9813196Issue 17-0 en

29/02/2008

EF - Base Control Function Handling

Page 29: NSN Zef

EFD DELETE BASE CONTROL FUNCTIONFunction With this command you delete a BCF object from the radio network (RNW)

database. A BCF object can be deleted only if there are no BTSs or TREsunder it.

Parameters BCF identification;

Syntax EFD: <BCF identification>;

Parameterexplanations

BCF identification

With this parameter you identify the BCF with a decimal number. The valuerange depends on the BSC hardware configuration and the correspondingoptions.

Examples 1. Delete the BCF object whose identification number is 128.

ZEFD:128;

Executionprintouts

The execution printout of command example 1 is the following:

BSC BSC-LAB 2007-10-10 13:54:32

BASE CONTROL FUNCTION BCF-0128 DELETED

COMMAND EXECUTED

Semantic errormessages

In error conditions, the general semantic error messages of the MMLcommands are output. For more information, see General NoticeMessages of MML Session.

Execution errormessages

/*** BCSU UPDATE ERROR ***/

DN9813196Issue 17-0 en29/02/2008

# Nokia Siemens Networks 29 (85)

EFD DELETE BASE CONTROL FUNCTION

Page 30: NSN Zef

The deletion was successful but updating one or more BCSUs failed. Afterthis message, a list of failed BCSU updates is output, for example, in thefollowing form:

/*** BCSU-05 NOT UPDATED ***/

/*** BCSU-07 NOT UPDATED ***/

In addition, the general execution error messages of the MML commandsare used. For more information, see Radio Network Administration andGeneral Error Messages of System.

30 (85) # Nokia Siemens Networks DN9813196Issue 17-0 en

29/02/2008

EF - Base Control Function Handling

Page 31: NSN Zef

EFM MODIFY BASE CONTROL FUNCTIONPARAMETERSFunction With this command you modify the BCF object's parameters in the BSS

Radio Network Configuration Database (BSDATA). The D-channel link setnumber must be created before this command can be used. If the BCF siteis synchronised, the master clock TRX must be defined under the BCF thatyou want to modify.

The command is not available for the Nokia InSite if it is waiting forautoconfiguration.

Parameters BCF identification: site type, D-channel link set number, D-channel link setname, RX difference limit, identification of test equipment, master clockTRX, external synchronisation source, automatic unlock allowed, BTSbattery backup procedure <option>, TRX shutdown timer <option>, TRXshutdown timer 2 <option>, TRX shutdown timer 3 <option>, BCCH TRXshutdown timer <option>, clock source, synch enabled, add BCF to chain,remove BCF from chain, text ID of the output 1, text ID of the output 2, textID of the output 3, text ID of the output 4, text ID of the output 5, text ID ofthe output 6: FACCH LAPDm T200, SDCCH LAPDm T200: Flexi EDGEAbis over IP Ethernet usage <option>, Flexi EDGE Additional 2 E1/T1usage <option>, Flexi EDGE TRS Abis Grooming usage <option>, FlexiEDGE TRS Loop Protection usage <option>;

Syntax

EFM: <BCF identification> :

( [ TYPE = <site type> |

DNBR = <D-channel link set number> |

DNAME = <D-channel link set name> |

RXDL = <RX difference limit> |

TEST = <identification of test equipment> |

MCT = <master clock TRX> |

ESS = <external synchronisation source> |

AU = <automatic unlock allowed> |

BBU = <BTS battery backup procedure> <option> |

DN9813196Issue 17-0 en29/02/2008

# Nokia Siemens Networks 31 (85)

EFM MODIFY BASE CONTROL FUNCTION PARAMETERS

Page 32: NSN Zef

NTIM = <TRX shutdown timer> <option> |

NTIM2 = <TRX shutdown timer 2> <option> |

NTIM3 = <TRX shutdown timer 3> <option> |

BTIM = <BCCH TRX shutdown timer>

CS = <clock source> |

SENA = <synch enabled> |

ADD = <add BCF to chain> ... |

REM = <remove BCF from chain> ... |

OUT1 = <text ID of the output 1> |

OUT2 = <text ID of the output 2> |

OUT3 = <text ID of the output 3> |

OUT4 = <text ID of the output 4> |

OUT5 = <text ID of the output 5> |

OUT6 = <text ID of the output 6> ] ... ) :

[ T200F = <FACCH LAPDm T200> |

T200S = <SDCCH LAPDm T200> ] :

[ TRS1 = <Flexi EDGE Abis over IP Ethernet usage> <option> |

TRS2 = <Flexi EDGE Additional 2 E1/T1 usage> <option> |

TRS3 = <Flexi EDGE TRS Abis Grooming usage> <option> |

TRS4 = <Flexi EDGE TRS Loop Protection usage> <option> ] ... );

Parameterexplanations

BCF identification

With this parameter you identify the BCF with a decimal number. The valuerange depends on the BSC hardware configuration and the correspondingoptions.

The parameter is obligatory.

site type

With this parameter you modify the BTS site type. The following BTS sitetype modifications are allowed:

. from Nokia 2nd generation to Nokia Talk-family,

. from Nokia 2nd generation to Nokia UltraSite,

. from Nokia Talk-family to Nokia 2nd generation,

. from Nokia Talk-family to Nokia UltraSite,

. from Nokia Talk-family to Nokia Flexi EDGE, and

. from Nokia UltraSite to Nokia Flexi EDGE.

The alternatives are:

32 (85) # Nokia Siemens Networks DN9813196Issue 17-0 en

29/02/2008

EF - Base Control Function Handling

Page 33: NSN Zef

Parameter Value Explanation

TYPE = B Nokia 2nd generation

D Nokia Talk-family

P Nokia UltraSite

E <option> Nokia Flexi EDGE

Tip

Check the BCF hardware database and the BCF software build.

Note

The base transceiver station (BTS) site type modification deletes thetransmission equipment under the modified base control function(BCF). The transmission equipment is updated automatically aftersome time. If the update needs to be faster, use the QUF MMLcommand for the BTSs with hardware database or the QWA MMLcommand for the BTSs without hardware database.

For more information, see .

Note

The operation and maintenance unit (OMU) link of the base controlfunction (BCF) cannot be in working (WO) state when the basetransceiver station (BTS) site type is modified to Nokia UltraSite orNokia Flexi EDGE.

D-channel link set number

DNBR = decimal number

With this parameter you modify the D-channel link set number of the BTSsite O&M link. You can give only one of the parameters DNBR and DNAMEin the same command.

This parameter cannot be given if the BCF is waiting for autoconfiguration.

DN9813196Issue 17-0 en29/02/2008

# Nokia Siemens Networks 33 (85)

EFM MODIFY BASE CONTROL FUNCTION PARAMETERS

Page 34: NSN Zef

For the Nokia PrimeSite, you cannot modify the D-channel link set number.

D-channel link set name

DNAME = identifier

With this parameter you modify the D-channel link set name of the BTSsite O&M link. The name can contain 1 to 5 characters. You can give onlyone of the parameters DNBR and DNAME in the same command.

This parameter cannot be given if the BCF is waiting for autoconfiguration.

For the Nokia PrimeSite, you cannot modify the D-channel link set name.

RX difference limit

RXDL = decimal number

With this parameter you define the value limit for activating the RX alarm.The BTS compares the main and diversity antenna RX levels and if thedifference is below this limit, an RX alarm is set.

The values range from 3 to 64 dB.

For site types Nokia UltraSite, Nokia MetroSite, Nokia 2nd generation, andNokia Flexi EDGE the value 64 dB indicates that no RX alarms are set.

The parameter is not available for the Nokia InSite site type.

identification of test equipment

With this parameter you define the test equipment connected to the BCF.

The parameters are:

Parameter Value Explanation

TEST = STM Site Test Monitor unit

RFTE Radio Frequency TestEquipment

NOT no test equipment

Value RFTE is allowed only for the Nokia 2nd generation site type.

34 (85) # Nokia Siemens Networks DN9813196Issue 17-0 en

29/02/2008

EF - Base Control Function Handling

Page 35: NSN Zef

The parameter is available only for the Nokia 2nd generation and NokiaTalk-family site types.

master clock TRX

MCT = decimal number

With this parameter you define the master clock TRX for the NokiaPrimeSite. The values range from 0 to 16. Value 0 indicates that the site isnot synchronised (stand-alone). Values 1 - 16 identify the master clockTRX (and indicate that the site is synchronised). If there is more than oneTRX in the site, the site must be synchronised (MCT≠0).

When you modify the master clock TRX, the BCF must be locked.

The parameter is only available for the Nokia PrimeSite.

external synchronisation source

With this parameter you define the synchronisation source of the masterclock TRX for a synchronised site. If the site is not synchronised but stand-alone, the parameter defines a synchronisation source for all the TRXs inthe site.

The values are:

Parameter Value Explanation

ESS = 0 BTS internal

2 PCM external

3 other external

When you modify the external synchronisation source, the BCF must belocked.

The parameter is only available for the Nokia PrimeSite.

automatic unlock allowed

With this parameter you define whether the automatic unlock is allowed forthe BCF or not.

The values are:

DN9813196Issue 17-0 en29/02/2008

# Nokia Siemens Networks 35 (85)

EFM MODIFY BASE CONTROL FUNCTION PARAMETERS

Page 36: NSN Zef

Parameter Value Explanation

AU = T Automatic unlock isallowed.

F Automatic unlock is notallowed.

You can give this parameter only if the site type is Nokia Flexi EDGE.

BTS battery backup procedure <option>

With this parameter you modify what type of BTS battery backupprocedure is used. The procedure is executed when the mains power goesdown at the BTS site and the battery backup unit exists.

The values are:

Parameter Value Explanation

BBU = ALL Transmission equipmentand all the TRXs are leftalive.

BCCH Transmission equipmentand only the BCCH TRXare left alive.

NONE Only transmissionequipment is left alive.

The parameter is not available for the Nokia PrimeSite or Nokia InSite sitetypes.

TRX shutdown timer <option>

NTIM = decimal number

With this parameter you define the time period after which shutdown group1 TRXs are powered down. The time starts after the TRX Shutdown Timer2 has expired. The parameter is valid only if the BTS Battery BackupProcedure (BBU) parameter has value BCCH or NONE.

The values range from 0 to 600 minutes.

The parameter is not available for the Nokia PrimeSite or Nokia InSite sitetypes.

TRX shutdown timer 2 <option>

36 (85) # Nokia Siemens Networks DN9813196Issue 17-0 en

29/02/2008

EF - Base Control Function Handling

Page 37: NSN Zef

NTIM2 = decimal number

With this parameter you define the time period after which shutdown group2 TRXs are powered down. The time starts after the TRX Shutdown Timer3 has expired. The parameter is valid only if the BTS Battery BackupProcedure (BBU) parameter has value BCCH or NONE.

The values range from 0 to 600 minutes.

The parameter is not available for the Nokia PrimeSite, Nokia InSite, orNokia 2nd generation site types.

TRX shutdown timer 3 <option>

NTIM3 = decimal number

With this parameter you define the time period after which shutdown group3 TRXs are powered down. The parameter is valid only if the BTSBattery Backup Procedure (BBU) parameter has value BCCH orNONE.

The values range from 0 to 600 minutes.

The parameter is not available for the Nokia PrimeSite, Nokia InSite, orNokia 2nd generation site types.

BCCH TRX shutdown timer <option>

BTIM = decimal number

With this parameter you define the time period after which shutdown group0 TRXs are powered down. The time starts after the TRX Shutdown Timer1 has expired. The parameter is valid only if the BTS Battery BackupProcedure (BBU) parameter has value BCCH or NONE. Also the BCCHTRXs are powered down when the BTS Battery Backup Procedure(BBU) parameter has value NONE.

The values range from 0 to 600 minutes.

The parameter is not available for the Nokia PrimeSite or Nokia InSite sitetypes.

clock source

DN9813196Issue 17-0 en29/02/2008

# Nokia Siemens Networks 37 (85)

EFM MODIFY BASE CONTROL FUNCTION PARAMETERS

Page 38: NSN Zef

With this parameter you define the clock source of the master clock BCF orthe independent mode BCF. The clock source of the master clock BCFmust be BCF, LMU, or LAB. You can remove the master clock BCF and allBCFs from the chain or the independent mode BCF from independentmode by defining the clock source to NONE.

You can modify the value of this parameter online from LMU to LAB. If theBCF chain is not in 'ABIS SYNCH' mode, you can modify the value of thisparameter from LAB to LMU online. Otherwise the parameter modificationrequires that the BCF's synch enabled (SENA) parameter has the valueN or that the BCF is locked. In the case of a BCF chain, all the BCFs in thechain must be locked.

The values are:

Parameter Value Explanation

CS = BCF master clock BCF

LMU Location Measurement Unit

LAB Location Measurement Unitwith Abis recovery (LMU-ABIS)

PCM independent mode

NONE remove clock source

The parameter is not available for the Nokia 2nd generation, NokiaPrimeSite, or Nokia InSite site types.

synch enabled

With this parameter you enable and disable the synchronisation of theBCF chain or the independent mode BCF. Enabling and disabling thesynchronisation is possible only when modifying the master clock BCF orthe independent mode BCF.

When you enable the synchronisation, the BCF must be locked.

When you disable the synchronisation, the BCF, and in the case of a BCFchain, all the BCFs in the chain must be locked.

The values are:

Parameter Value Explanation

SENA = T Synchronisation enabled.

38 (85) # Nokia Siemens Networks DN9813196Issue 17-0 en

29/02/2008

EF - Base Control Function Handling

Page 39: NSN Zef

Parameter Value Explanation

F Synchronisation disabled.

The parameter is not available for the Nokia 2nd generation, NokiaPrimeSite, or Nokia InSite site types.

add BCF to chain

ADD = decimal number

With this parameter you add BCFs to the chain under the master clockBCF. The value range depends on the BSC hardware configuration andthe corresponding options. You can enter several values at the same timeby using the grouping character &. You can define at the most 8 BCFs to achain under a master clock BCF. The definition is done when modifying themaster clock BCF.

You can add a slave BCF to synch enabled BCF chain if the slave BCF islocked.

The parameter is not available for the Nokia 2nd generation, NokiaPrimeSite, or Nokia InSite site types.

remove BCF from chain

REM = decimal number

With this parameter you remove BCFs from a chain. The value rangedepends on the BSC hardware configuration and the correspondingoptions. You can enter several values at the same time by using thecharacter &. The definition is done when modifying the master clock BCF.

You can remove a slave BCF from synch enabled BCF chain if the slaveBCF is locked.

The parameter is not available for the Nokia 2nd generation, NokiaPrimeSite, or Nokia InSite site types.

text ID of the output from 1 to 6

OUT1...OUT6 = decimal number

With this parameter you define the text ID for the external output. Thevalues range from 1 to 200.

To remove the output's text ID, enter the value 0 (0 = text not defined).

DN9813196Issue 17-0 en29/02/2008

# Nokia Siemens Networks 39 (85)

EFM MODIFY BASE CONTROL FUNCTION PARAMETERS

Page 40: NSN Zef

The parameter is only available for the Nokia MetroSite, Nokia UltraSite,and Nokia Flexi EDGE.

Nokia MetroSite has 4 external outputs, whereas Nokia UltraSite andNokia Flexi EDGE have 6 external outputs.

FACCH LAPDm T200

T200F = decimal number

With this parameter you define an LAPDm for the supervision of theFACCH message transfer from the BTS to the mobile. The values rangefrom 200 to 1260 ms, in20 ms steps.

This parameter is supported only by Nokia Talk-family, Nokia UltraSite,and Nokia Flexi EDGE site types.

SDCCH LAPDm T200

T200S = decimal number

With this parameter you define an LAPDm for the supervision of theSDCCH message transfer from the BTS to the mobile. The values rangefrom 220 to 1260 ms, in 20 ms steps.

This parameter is supported only by Nokia Talk-family, Nokia UltraSite,and Nokia Flexi EDGE site types.

Flexi EDGE Abis over IP Ethernet usage <option>

With this parameter you enable Flexi EDGE Abis over IP/ Ethernet in theBCF.

The values are:

Parameter Value Explanation

TRS1 = 0 Flexi EDGE Abis over IP/Ethernet not in use.

1 Flexi EDGE Abis over IP/Ethernet in use.

This parameter is valid only for Nokia Flexi EDGE site type.

Flexi EDGE Additional 2 E1/T1 usage <option>

40 (85) # Nokia Siemens Networks DN9813196Issue 17-0 en

29/02/2008

EF - Base Control Function Handling

Page 41: NSN Zef

With this parameter you enable Flexi EDGE Additional 2 E1/T1 in the BCF.

The values are:

Parameter Value Explanation

TRS2 = 0 2 E1/T1 free interfaces inuse.

1 Additional 2 E1/T1interface in use.

2 2 additional 2 E1/T1interfaces in use.

3 3 additional 2 E1/T1interfaces in use.

This parameter is valid only for Nokia Flexi EDGE site type.

Flexi EDGE TRS Abis Grooming usage <option>

With this parameter you enable Flexi EDGE TRS Abis Grooming in theBCF.

The values are:

Parameter Value Explanation

TRS3 = 0 Flexi EDGE TRS AbisGrooming not in use.

1 Flexi EDGE TRS AbisGrooming in use.

This parameter is valid only for Nokia Flexi EDGE site type.

Flexi EDGE TRS Loop Protection usage <option>

With this parameter you enable Flexi EDGE TRS Loop Protection in theBCF.

The values are:

Parameter Value Explanation

TRS4 = 0 Flexi EDGE TRS LoopProtection not in use.

DN9813196Issue 17-0 en29/02/2008

# Nokia Siemens Networks 41 (85)

EFM MODIFY BASE CONTROL FUNCTION PARAMETERS

Page 42: NSN Zef

Parameter Value Explanation

1 Flexi EDGE TRS LoopProtection in use.

This parameter is valid only for Nokia Flexi EDGE site type.

Examples 1. In BCF-128, modify the D-channel link set number to 10.

ZEFM:128:DNBR=10;

2. In BCF-12, modify the test equipment information to RFTE.

ZEFM:12:TEST=RFTE;

3. In BCF-12, modify the D-channel link set number to 22, set the BTSbattery backup procedure to BCCH and BCCH TRX shutdown timerto 20 minutes, and set the test equipment information to RFTE.

ZEFM:12:DNBR=22,TEST=RFTE,BBU=BCCH,BTIM=20;

4. In BCF-101 of Nokia PrimeSite, modify the site's master clock TRXto TRX 2 and external synchronisation source to PCM external.

ZEFM:101:MCT=2,ESS=2;

5. In BCF-120, modify the text ID number of output 2 to value 5.

ZEFM:120:OUT2=5;

6. In BCF-130, define the BCF as the master clock BCF and set theclock source to BCF, enable the synchronisation of the chain andadd BCFs 131 and 132 to the chain.

ZEFM:130:CS=BCF,SENA=T,ADD=131&132;

7. Remove master clock BCF number 130 and all BCFs from the chainunder the master clock BCF.

ZEFM:130:CS=NONE;

8. Remove BCFs 108, 109, and 110 from the chain under the masterclock BCF number 105.

ZEFM:105:REM=108&109&110;

Executionprintouts

The printout of the command ZEFM:128:TYPE=B,DNBR=43,TEST=NOT;for Nokia 2nd generation is the following:

BSC BSC-LAB 2007-10-10 13:54:32

BASE CONTROL FUNCTION BCF-0128 MODIFIED

SITE TYPE ............................ B - 2ND GEN

42 (85) # Nokia Siemens Networks DN9813196Issue 17-0 en

29/02/2008

EF - Base Control Function Handling

Page 43: NSN Zef

D-CHANNEL LINK SET 43 ............. FU21

RX DIFFERENCE LIMIT ..........(RXDL).. 10 dB

TEST EQUIPMENT ...............(TEST).. --

BTS BATTERY BACKUP PROCEDURE .(BBU)... ALL

TRX SHUTDOWN TIMER ...........(NTIM).. 0 min

BCCH TRX SHUTDOWN TIMER ......(BTIM).. 0 min

DEFAULT BCF SOFTWARE BUILD ATTACHED

COMMAND EXECUTED

The printout of the command ZEFM:127:MCT=1,ESS=2; for NokiaPrimeSite is the following:

BSC BSC-LAB 2007-10-10 13:55:37

BASE CONTROL FUNCTION BCF-0127 MODIFIED

SITE TYPE ............................ F - PRIMESITE

RX DIFFERENCE LIMIT ..........(RXDL).. 10 dB

MASTER CLOCK TRX .............(MCT)... 1

EXTERNAL SYNC SOURCE .........(ESS)... 2 (PCM EXTERNAL)

COMMAND EXECUTED

The printout of the command ZEFM:120:OUT2=5; for Nokia MetroSite isthe following:

BSC BSC-LAB 2007-10-10 15:16:31

BASE CONTROL FUNCTION BCF-0120 MODIFIED

SITE TYPE ............................ C - METROSITE

D-CHANNEL LINK SET 9 ............. FU4

OUTPUT 1 ........................ ON TEXT ID 2

ADDITIONAL COOLER FAN

OUTPUT 2 ........................ ON TEXT ID 5

MAST WARNING LIGHTS

OUTPUT 3 ........................ OFF TEXT ID -

OUTPUT 4 ........................ OFF TEXT ID -

RX DIFFERENCE LIMIT ..........(RXDL).. 10 dB

BTS BATTERY BACKUP PROCEDURE .(BBU)... ALL

TRX SHUTDOWN TIMER ...........(NTIM).. 0 min

TRX SHUTDOWN TIMER 2 .........(NTIM2). 0 min

TRX SHUTDOWN TIMER 3 .........(NTIM3). 0 min

BCCH TRX SHUTDOWN TIMER ......(BTIM).. 0 min

MASTER CLOCK BCF .............(MCBCF). ––

CLOCK SOURCE .................(CS).... PCM

SYNCHRONIZATION ENABLED ......(SENA).. T

SYNCHRONIZATION MODE .........(SM).... SYNCH

COMMAND EXECUTED

DN9813196Issue 17-0 en29/02/2008

# Nokia Siemens Networks 43 (85)

EFM MODIFY BASE CONTROL FUNCTION PARAMETERS

Page 44: NSN Zef

The printout of the command ZEFM:100:RXDL=20; for Nokia UltraSite isthe following:

BSC BSC-LAB 2007-10-10 05:08:37

BASE CONTROL FUNCTION BCF-0100 MODIFIED

SITE TYPE ............................ P - ULTRASITE

D-CHANNEL LINK SET 135 ............. FU67

OUTPUT 1 ....................... OFF TEXT ID -

OUTPUT 2 ....................... OFF TEXT ID -

OUTPUT 3 ....................... OFF TEXT ID -

OUTPUT 4 ....................... OFF TEXT ID -

OUTPUT 5 ....................... OFF TEXT ID -

OUTPUT 6 ....................... OFF TEXT ID -

RX DIFFERENCE LIMIT ..........(RXDL).. 20 dB

BTS BATTERY BACKUP PROCEDURE .(BBU)... ALL

TRX SHUTDOWN TIMER ...........(NTIM).. 0 min

TRX SHUTDOWN TIMER 2 .........(NTIM2). 0 min

TRX SHUTDOWN TIMER 3 .........(NTIM3). 0 min

BCCH TRX SHUTDOWN TIMER ......(BTIM).. 0 min

MASTER CLOCK BCF .............(MCBCF). ––

CLOCK SOURCE .................(CS).... ––

SYNCHRONIZATION ENABLED ......(SENA).. F

SYNCHRONIZATION MODE .........(SM).... UNSYNCH

FACCH LAPDM T200 .............(T200F). 0 (BCF PREDEFINED VALUE)

SDCCH LAPDM T200 .............(T200S). 0 (BCF PREDEFINED VALUE)

COMMAND EXECUTED

Semantic errormessages

/*** BCF IS NOT DEFINED TO MASTER CLOCK BCF ***/

You have attempted to modify a parameter which is allowed only for themaster clock BCF.

/*** CHAIN BCF NOT FOUND IN BSC DATABASE ***/

The BCF, which you have attempted to add to the chain under the masterclock BCF, does not exist.

In addition, the general semantic error messages of the MML commandsare output. For more information, see General Notice Messages of MMLSession.

44 (85) # Nokia Siemens Networks DN9813196Issue 17-0 en

29/02/2008

EF - Base Control Function Handling

Page 45: NSN Zef

Execution errormessages

/*** ATTACHMENT OF DEFAULT BCF SOFTWARE BUILD FAILED ***/

The BCF modification was successful but attaching the software buildfailed.

/*** BCSU UPDATE ERROR ***/

The modification was successful but updating one or more BCSUs failed.After this message, a list of failed BCSU updates is output, for example, inthe following form:

/*** BCSU-05 NOT UPDATED ***/

/*** BCSU-07 NOT UPDATED ***/

In addition, the general execution error messages of the MML commandsare used. For more information, see Radio Network Administration andGeneral Error Messages of System.

DN9813196Issue 17-0 en29/02/2008

# Nokia Siemens Networks 45 (85)

EFM MODIFY BASE CONTROL FUNCTION PARAMETERS

Page 46: NSN Zef

46 (85) # Nokia Siemens Networks DN9813196Issue 17-0 en

29/02/2008

EF - Base Control Function Handling

Page 47: NSN Zef

EFO OUTPUT BASE CONTROL FUNCTIONPARAMETERSFunction With this command you output the BCF object parameters.

You can identify the BCF with the BCF number. You can also identifymultiple BCF numbers by using the grouping characters & and &&. Theprogram displays the data on those BCFs that are stored in the BSS RadioNetwork Configuration Database (BSDATA).

If you do not identify the BCF, the data on all BCFs in the BSDATA isdisplayed.

The command also displays the identification and the administrative stateof the BTSs controlled by the BCF and the identification of the segments(SEGs) where the BTSs are located.

Parameters BCF identification: parameter group;

Syntax EFO: [ <BCF identification> ... | <all> def ] :

[ <parameter group> | IDE def ] ;

Parameterexplanations

BCF identification

With this parameter you identify the BCF with a decimal number. The valuerange depends on the BSC hardware configuration and the correspondingoptions.

You can enter multiple BCFs by using the grouping characters & and &&. Ifyou do not enter the parameter, all BCFs that exist are output.

parameter group

With this parameter you identify the BCF parameter group that is output.

DN9813196Issue 17-0 en29/02/2008

# Nokia Siemens Networks 47 (85)

EFO OUTPUT BASE CONTROL FUNCTION PARAMETERS

Page 48: NSN Zef

IDE BCF identification parameters

HOP frequency hopping parameters

IOP external inputs and outputs of the BCF

ALL all parameters

The default value is the IDE parameter group.

Examples 1. Output the BCF identification parameters of BCFs 1 and from 3 to 8.

ZEFO:1&3&&8;

2. Output the frequency hopping parameters of BCFs number 1 and 2.

ZEFO:1&2:HOP;

3. Output all BCF parameters of BCFs 1 to 28.

ZEFO:1&&28:ALL;

4. Output the external inputs and outputs of BCF 128.

ZEFO:128:IOP;

Executionprintouts

The abbreviations used in the execution printout are:

ABIS SYNCH= BSS synchronised using Abis

AD= activation denied

BL= blocked

BL-BCF= blocked-bcf_fault

The object is blocked out of use due to a fatal BTS-site-wide failure.

BL-BTS= blocked-bts_fault

The object is blocked out of use due to a fatal sector-wide failure on the BTS site.

BL-DGN= blocked-diagnostic

The object is blocked temporarily out of use due tobase station diagnostic activities.

BL-PWR= blocked-mains_power_fault_or_manual_power_down

The object is blocked out of use due to a mains powerfailure or manual TRX power down on the BTS site.

BL-RSL= blocked-rsl_fault

The object is blocked out of use due to a telecom AbisD-channel link disconnection.

48 (85) # Nokia Siemens Networks DN9813196Issue 17-0 en

29/02/2008

EF - Base Control Function Handling

Page 49: NSN Zef

BL-RST= blocked-reset

The logical radio network object is blocked out of usedue to the reset of the corresponding physical radionetwork equipment.

BL-SHD= blocked-shutting_down

The object will be blocked out of use within a timelimit. New call attempts are prohibited via an object inthe BL-SHD state and forced handovers are executedfor ongoing calls via the object.

BL-SU= blocked-bcsu_reset

The object is blocked out of use due to a BCSU unitreset on the BSC.

BL-SWO= blocked-file_based_plan_provisioning_activation

The object is blocked out of use due to File BasedPlan Provisioning activation.

BL-SYS= blocked-system

The radio network management function class of theBSC has blocked the logical object out of use due toongoing radio network recovery actions which aretriggered because of fatal faults in the BSS radionetwork.

BL-TRX= blocked-trx_fault

The object is blocked out of use due to a fatal TRX-wide failure on the BTS site.

BL-TST= blocked-testing

The object is blocked temporarily out of use due toradio network testing activities.

BL-USR= blocked-user

The operator has blocked the object out of use. Theadministrative state of the object is LOCKED or therelated higher-level object is LOCKED.

BL-WAC= blocked-waiting_for_autoconfiguration

The object is blocked out of use.

DFCA= Dynamic Frequency and Channel Allocation

EX= executing

F= false

L= locked

LMU= Location Measurement Unit

LMU SYNCH= BSS synchronised using Location Measurement Unit

DN9813196Issue 17-0 en29/02/2008

# Nokia Siemens Networks 49 (85)

EFO OUTPUT BASE CONTROL FUNCTION PARAMETERS

Page 50: NSN Zef

RFTE= Radio Frequency Test Equipment

SD= shutting down

SP= spare

STM= Site Test Monitor unit

SY= system

SYNCH= synchronised

T= true

U= unlocked

UA= unavailable

UNSYNCH= unsynchronised

US= user

WO= working

WO-EX= working-executing

The execution printout of the command ZEFO:125; for Nokia UltraSite isthe following:

BSC BSC-LAB 2007-10-10 13:54:32

BASE CONTROL FUNCTION BCF-0125 DATA

SITE TYPE ............................ P - ULTRASITE

ADMINISTRATIVE STATE ................. UNLOCKED

OPERATIONAL STATE .................... WO

D-CHANNEL LINK SET 1 ............. OMU12 WO-EX

RX DIFFERENCE LIMIT ..........(RXDL).. 10 dB

TEST EQUIPMENT ...............(TEST).. STM

BTS BATTERY BACKUP PROCEDURE .(BBU)... ALL

TRX SHUTDOWN TIMER ...........(NTIM).. 0 min

TRX SHUTDOWN TIMER 2 .........(NTIM2). 0 min

TRX SHUTDOWN TIMER 3 .........(NTIM3). 0 min

BCCH TRX SHUTDOWN TIMER ......(BTIM).. 0 min

MASTER CLOCK BCF .............(MCBCF). 0100

SYNCHRONIZATION MODE .........(SM).... SYNCH

FACCH LAPDM T200 .............(T200F). 0 (BCF PREDEFINED VALUES)

SDCCH LAPDM T200 .............(T200S). 0 (BCF PREDEFINED VALUES)

BTS UNDER THIS BCF ARE:

BTS-0001 SECTOR-001 CITY1 ..... LOCKED

BTS-0002 SECTOR-002 CITY2 ..... UNLOCKED

BTS-0003 SECTOR-003 CITY3 ..... LOCKED

COMMAND EXECUTED

The execution printout of the command ZEFO:126; for Nokia Flexi EDGEis the following:

50 (85) # Nokia Siemens Networks DN9813196Issue 17-0 en

29/02/2008

EF - Base Control Function Handling

Page 51: NSN Zef

BSC BSC-LAB 2007-10-10 13:54:32

BASE CONTROL FUNCTION BCF-0126 DATA

SITE TYPE ............................ E - FLEXI EDGE

ADMINISTRATIVE STATE ................. UNLOCKED

OPERATIONAL STATE .................... WO

D-CHANNEL LINK SET 1 ............. OMU12 WO-EX

RX DIFFERENCE LIMIT ..........(RXDL).. 10 dB

TEST EQUIPMENT ...............(TEST).. STM

BTS BATTERY BACKUP PROCEDURE .(BBU)... ALL

TRX SHUTDOWN TIMER ...........(NTIM).. 0 min

TRX SHUTDOWN TIMER 2 .........(NTIM2). 0 min

TRX SHUTDOWN TIMER 3 .........(NTIM3). 0 min

BCCH TRX SHUTDOWN TIMER ......(BTIM).. 0 min

MASTER CLOCK BCF .............(MCBCF). 0100

SYNCHRONIZATION MODE .........(SM).... SYNCH

AUTOMATIC UNLOCK ALLOWED .....(AU).... T

FACCH LAPDM T200 .............(T200F). 0 (BCF PREDEFINED VALUES)

SDCCH LAPDM T200 .............(T200S). 0 (BCF PREDEFINED VALUES)

ABIS OVER IP ETHERNET USAGE ..(TRS1).. NOT DEFINED

ADDITIONAL 2 E1/T1 USAGE .....(TRS2).. NOT DEFINED

TRS ABIS GROOMING USAGE ......(TRS3).. NOT DEFINED

TRS LOOP PROTECTION USAGE ....(TRS4).. NOT DEFINED

BTS UNDER THIS BCF ARE:

BTS-0001 SECTOR-001 CITY1 ..... LOCKED

BTS-0002 SECTOR-002 CITY2 ..... UNLOCKED

BTS-0003 SECTOR-003 CITY3 ..... LOCKED

COMMAND EXECUTED

The execution printout of the command ZEFO:127; for Nokia PrimeSite isthe following:

BSC BSC-LAB 2007-10-10 13:54:54

BASE CONTROL FUNCTION BCF-0127 DATA

SITE TYPE ............................ F - PRIMESITE

ADMINISTRATIVE STATE ................. UNLOCKED

OPERATIONAL STATE .................... WO

RX DIFFERENCE LIMIT ..........(RXDL).. 10 dB

MASTER CLOCK TRX .............(MCT)... 1

EXTERNAL SYNC SOURCE .........(ESS)... 2 (PCM EXTERNAL)

BTS UNDER THIS BCF ARE:

BTS-0004 SECTOR-001 CITY4 ..... LOCKED

BTS-0005 SECTOR-002 CITY5 ..... UNLOCKED

BTS-0006 SECTOR-003 CITY6 ..... LOCKED

COMMAND EXECUTED

The execution printout of the command ZEFO:1&&3:HOP; is thefollowing:

DN9813196Issue 17-0 en29/02/2008

# Nokia Siemens Networks 51 (85)

EFO OUTPUT BASE CONTROL FUNCTION PARAMETERS

Page 52: NSN Zef

BSC BSC-LAB 2007-10-10 12:54:32

FREQUENCY HOPPING PARAMETERS:

=============================

SEG-0003 CENTRE003

BCF-0001 BTS-0007 CITY7

-------------------------------------

BTS ADMINISTRATIVE STATE ... UNLOCKED

BTS OPERATIONAL STATE ...... WO

BTS HOPPING MODE..................(HOP).... BB (BASEBAND HOPPING)

BACKGROUND BTS HOPPING MODE.......(BHOP)... -

HOPPING SEQUENCE NUMBER 1......(HSN1)... 12

BACKGROUND HSN1................(BHSN1).. -

HOPPING SEQUENCE NUMBER 2......(HSN2)... 16

BACKGROUND HSN2................(BHSN2).. -

MAIO OFFSET....................(MO)..... 0 *)

BACKGROUND MAIO OFFSET.........(BMO).... -

MAIO STEP......................(MS)..... 1 *)

BACKGROUND MAIO STEP...........(BMS).... -

MOBILE ALLOCATION FREQ LIST....(MAL).... - *)

BACKGROUND MA FREQ LIST........(BMAL)... -

UNDERLAY BTS HOPPING MODE.........(UHOP)... BB (BASEBAND HOPPING)

BG UNDERLAY BTS HOPPING MODE......(BUHOP).. -

UNDERLAY HOP SEQ NUMBER........(UHSN)... 10

BG UNDERLAY HOP SEQ NUMBER.....(BUHSN).. -

UNDERLAY MAIO OFFSET...........(UMO).... 0 *)

BG UNDERLAY MAIO OFFSET........(BUMO)... -

UNDERLAY MAIO STEP.............(UMS).... 1 *)

BG UNDERLAY MAIO STEP..........(BUMS)... -

UNDERLAY MA FREQUENCY LIST.....(UMAL)... - *)

BG UNDERLAY MA FREQUENCY LIST..(BUMAL).. -

DFCA MODE ........................(DMOD)... OFF

DFCA MA FREQ LIST(S)...........(DMAL)... -

DFCA UNSYNC MODE MA FREQ LIST..(DUMAL).. - *)

MAIO VALUES PER RADIO TIMESLOT:

OVERLAY TRXS:

ADM. OP.

STATE STATE FREQ RTSL0 RTSL1 RTSL2 RTSL3 RTSL4 RTSL5 RTSL6 RTSL7

TRX-001 U WO 12 BCCH 0 0 0 0 0 0 0

TRX-002 U WO 64 0 1 1 1 1 1 1 1

TRX-003 U WO 96 1 2 2 2 2 2 2 2

TRX-004 L BL-USR 124 - - - - - - - -

UNDERLAY TRXS:

TRX-005 U WO 2 0 0 0 0 0 0 0 0

TRX-006 U WO 8 1 1 1 1 1 1 1 1

TRX-007 U WO 18 2 2 2 2 2 2 2 2

TRX-008 U WO 32 3 3 3 3 3 3 3 3

52 (85) # Nokia Siemens Networks DN9813196Issue 17-0 en

29/02/2008

EF - Base Control Function Handling

Page 53: NSN Zef

SEG-0003 CENTRE03

BCF-0001 BTS-0080 CITY80

-------------------------------------

BTS ADMINISTRATIVE STATE ... LOCKED

BTS OPERATIONAL STATE ...... BL-USR

BTS HOPPING MODE..................(HOP).... BB (BASEBAND HOPPING)

BACKGROUND BTS HOPPING MODE.......(BHOP)... -

HOPPING SEQUENCE NUMBER 1......(HSN1)... 12

BACKGROUND HSN1................(BHSN1).. -

HOPPING SEQUENCE NUMBER 2......(HSN2)... 16

BACKGROUND HSN2................(BHSN2).. -

MAIO OFFSET....................(MO)..... 0 *)

BACKGROUND MAIO OFFSET.........(BMO).... -

MAIO STEP......................(MS)..... 1 *)

BACKGROUND MAIO STEP...........(BMS).... -

MOBILE ALLOCATION FREQ LIST....(MAL).... - *)

BACKGROUND MA FREQ LIST........(BMAL)... -

UNDERLAY BTS HOPPING MODE.........(UHOP)... N (NOT HOPPING)

BG UNDERLAY BTS HOPPING MODE......(BUHOP).. -

UNDERLAY HOP SEQ NUMBER........(UHSN)... 0

BG UNDERLAY HOP SEQ NUMBER.....(BUHSN).. -

UNDERLAY MAIO OFFSET...........(UMO).... 0 *)

BG UNDERLAY MAIO OFFSET........(BUMO)... -

UNDERLAY MAIO STEP.............(UMS).... 1 *)

BG UNDERLAY MAIO STEP..........(BUMS)... -

UNDERLAY MA FREQUENCY LIST.....(UMAL)... - *)

BG UNDERLAY MA FREQUENCY LIST..(BUMAL).. -

DFCA MODE ........................(DMOD)... OFF

DFCA MA FREQ LIST(S)...........(DMAL)... -

DFCA UNSYNC MODE MA FREQ LIST..(DUMAL).. - *)

MAIO VALUES PER RADIO TIMESLOT:

OVERLAY TRXS:

ADM. OP.

STATE STATE FREQ RTSL0 RTSL1 RTSL2 RTSL3 RTSL4 RTSL5 RTSL6 RTSL7

TRX-001 U BL-USR 31 - - - - - - - -

TRX-002 U BL-USR 32 - - - - - - - -

TRX-003 U BL-USR 33 - - - - - - - -

THERE IS NO UNDERLAY TRX UNDER BTS

SEG-0003 CENTRE03

BCF-0002 BTS-0008 CITY8

-------------------------------------

BTS ADMINISTRATIVE STATE ... UNLOCKED

BTS OPERATIONAL STATE ...... WO

BTS HOPPING MODE..................(HOP).... RF (RF HOPPING)

BACKGROUND BTS HOPPING MODE.......(BHOP)... -

HOPPING SEQUENCE NUMBER 1 .....(HSN1)... 8

BACKGROUND HSN1................(BHSN1).. -

DN9813196Issue 17-0 en29/02/2008

# Nokia Siemens Networks 53 (85)

EFO OUTPUT BASE CONTROL FUNCTION PARAMETERS

Page 54: NSN Zef

HOPPING SEQUENCE NUMBER 2 .....(HSN2)... 0 *)

BACKGROUND HSN2................(BHSN2).. -

MAIO OFFSET....................(MO)..... 0

BACKGROUND MAIO OFFSET.........(BMO).... -

MAIO STEP......................(MS)..... 1

BACKGROUND MAIO STEP...........(BMS).... -

MOBILE ALLOCATION FREQ LIST....(MAL).... 110

FREQUENCIES:

4 6 12 96 102 108 114 120 124

BACKGROUND MA FREQ LIST........(BMAL)... -

UNDERLAY BTS HOPPING MODE.........(UHOP)... RF (RF HOPPING)

BG UNDERLAY BTS HOPPING MODE......(BUHOP).. -

UNDERLAY HOP SEQ NUMBER........(UHSN)... 0

BG UNDERLAY HOP SEQ NUMBER.....(BUHSN).. -

UNDERLAY MAIO OFFSET...........(UMO).... 0

BG UNDERLAY MAIO OFFSET........(BUMO)... -

UNDERLAY MAIO STEP.............(UMS).... 1

BG UNDERLAY MAIO STEP..........(BUMS)... -

UNDERLAY MA FREQUENCY LIST.....(UMAL)... -

BG UNDERLAY MA FREQUENCY LIST..(BUMAL).. -

DFCA MODE ........................(DMOD)... STANDBY

DFCA MA FREQ LIST(S)...........(DMAL)... 2001 2005 2007

DFCA UNSYNC MODE MA FREQ LIST..(DUMAL).. 209 *)

MAIO VALUES PER RADIO TIMESLOT:

OVERLAY TRXS:

ADM. OP.

STATE STATE FREQ RTSL0 RTSL1 RTSL2 RTSL3 RTSL4 RTSL5 RTSL6 RTSL7

TRX-005 U WO 24 BCCH - - - - - - -

TRX-006 U WO 35 0 0 0 0 0 0 0 0

TRX-007 U WO 54 1 1 1 1 1 1 1 1

TRX-008 U WO 59 2 2 2 2 2 2 2 2

THERE IS NO UNDERLAY TRX UNDER BTS

SEG-0004 CENTRE04

BCF-0002 BTS-0009 CITY9

-------------------------------------

BTS ADMINISTRATIVE STATE ... UNLOCKED

BTS OPERATIONAL STATE ...... WO

BTS HOPPING MODE..................(HOP).... RF (RF HOPPING)

BACKGROUND BTS HOPPING MODE.......(BHOP)... -

HOPPING SEQUENCE NUMBER 1 .....(HSN1)... 6

BACKGROUND HSN1................(BHSN1).. -

HOPPING SEQUENCE NUMBER 2 .....(HSN2)... 0 *)

BACKGROUND HSN2................(BHSN2).. -

MAIO OFFSET....................(MO)..... 3

BACKGROUND MAIO OFFSET.........(BMO).... -

MAIO STEP......................(MS)..... 1

BACKGROUND MAIO STEP...........(BMS).... -

MOBILE ALLOCATION FREQ LIST....(MAL).... 110

54 (85) # Nokia Siemens Networks DN9813196Issue 17-0 en

29/02/2008

EF - Base Control Function Handling

Page 55: NSN Zef

FREQUENCIES:

4 6 12 96 102 108 114 120 124

BACKGROUND MA FREQ LIST.......(BMAL)... -

UNDERLAY BTS HOPPING MODE.........(UHOP)... N (NOT HOPPING)

BG UNDERLAY BTS HOPPING MODE......(BUHOP).. -

UNDERLAY HOP SEQ NUMBER........(UHSN)... 0

BG UNDERLAY HOP SEQ NUMBER.....(BUHSN).. -

UNDERLAY MAIO OFFSET...........(UMO).... 0 *)

BG UNDERLAY MAIO OFFSET........(BUMO)... -

UNDERLAY MAIO STEP.............(UMS).... 1 *)

BG UNDERLAY MAIO STEP..........(BUMS)... -

UNDERLAY MA FREQUENCY LIST.....(UMAL)... - *)

BG UNDERLAY MA FREQUENCY LIST..(BUMAL).. -

DFCA MODE ........................(DMOD)... DFCA

DFCA MA FREQ LIST(S)...........(DMAL)... 2001 2005 2007

DFCA UNSYNC MODE MA FREQ LIST..(DUMAL).. 120

FREQUENCIES:

8 14 24 68 88 104 110 116 122

MAIO VALUES PER RADIO TIMESLOT:

OVERLAY TRXS:

ADM. OP.

STATE STATE FREQ RTSL0 RTSL1 RTSL2 RTSL3 RTSL4 RTSL5 RTSL6 RTSL7

TRX-009 U WO 64 BCCH - - - - - - -

TRX-010 U WO 87 3 3 3 3 3 3 3 3

TRX-011 U WO 45 4 4 4 4 4 4 4 4

TRX-012 U WO 121 5 5 5 5 5 5 5 5

THERE IS NO UNDERLAY TRX UNDER BTS

DFCA TRXS:

TRX-013 U WO 75 1 1 1 1 1 1 1 1

TRX-014 U WO 79 3 3 3 3 3 3 3 3

TRX-015 U WO 83 5 5 5 5 5 5 5 5

SEG-0004 CENTRE04

BCF-0002 BTS-0010 CITY10

-------------------------------------

BTS ADMINISTRATIVE STATE ... UNLOCKED

BTS OPERATIONAL STATE ...... WO

BTS HOPPING MODE..................(HOP).... RF (RF HOPPING)

BACKGROUND BTS HOPPING MODE.......(BHOP)... -

HOPPING SEQUENCE NUMBER 1 .....(HSN1)... 20

BACKGROUND HSN1................(BHSN1).. -

HOPPING SEQUENCE NUMBER 2 .....(HSN2)... 0 *)

BACKGROUND HSN2................(BHSN2).. -

MAIO OFFSET....................(MO)..... 6

BACKGROUND MAIO OFFSET.........(BMO).... -

MAIO STEP......................(MS)..... 1

BACKGROUND MAIO STEP...........(BMS).... -

MOBILE ALLOCATION FREQ LIST....(MAL).... 110

DN9813196Issue 17-0 en29/02/2008

# Nokia Siemens Networks 55 (85)

EFO OUTPUT BASE CONTROL FUNCTION PARAMETERS

Page 56: NSN Zef

FREQUENCIES:

4 6 12 96 102 108 114 120 124

BACKGROUND MA FREQ LIST........(BMAL)... -

UNDERLAY BTS HOPPING MODE.........(UHOP)... RF (RF HOPPING)

BG UNDERLAY BTS HOPPING MODE......(BUHOP).. -

UNDERLAY HOP SEQ NUMBER........(UHSN)... 22

BG UNDERLAY HOP SEQ NUMBER.....(BUHSN).. -

UNDERLAY MAIO OFFSET...........(UMO).... 9

BG UNDERLAY MAIO OFFSET........(BUMO)... -

UNDERLAY MAIO STEP.............(UMS).... 1

BG UNDERLAY MAIO STEP..........(BUMS)... -

UNDERLAY MA FREQUENCY LIST.....(UMAL)... 112

FREQUENCIES:

1 3 21 23 45 49 77 81 85 89

113 117 119 121

BG UNDERLAY MA FREQUENCY LIST..(BUMAL).. -

DFCA MODE ........................(DMOD)... DFCA

DFCA MA FREQ LIST(S)...........(DMAL)... 2001 2005 2007

DFCA UNSYNC MODE MA FREQ LIST..(DUMAL).. 36 *)

MAIO VALUES PER RADIO TIMESLOT:

OVERLAY TRXS:

ADM. OP.

STATE STATE FREQ RTSL0 RTSL1 RTSL2 RTSL3 RTSL4 RTSL5 RTSL6 RTSL7

TRX-013 U WO 96 BCCH - - - - - - -

TRX-014 U WO 6 6 6 6 6 6 6 6

TRX-015 U WO 7 7 7 7 7 7 7 7

TRX-016 U WO 8 8 8 8 8 8 8 8

UNDERLAY TRXS:

TRX-001 U WO 9 9 9 9 9 9 9 9

TRX-002 U WO 10 10 10 10 10 10 10 10

TRX-003 U WO 11 11 11 11 11 11 11 11

TRX-004 U WO 12 12 12 12 12 12 12 12

THERE IS NO DFCA TRX UNDER BTS

SEG-0004 CENTRE04

BCF-0003 BTS-0011 CITY11

-------------------------------------

BTS ADMINISTRATIVE STATE ... UNLOCKED

BTS OPERATIONAL STATE ...... WO

BTS HOPPING MODE..................(HOP).... N (NOT HOPPING)

BACKGROUND BTS HOPPING MODE.......(BHOP)... -

HOPPING SEQUENCE NUMBER 1 .....(HSN1)... 0 *)

BACKGROUND HSN1................(BHSN1).. -

HOPPING SEQUENCE NUMBER 2 .....(HSN2)... 0 *)

BACKGROUND HSN2................(BHSN2).. -

MAIO OFFSET....................(MO)..... 0 *)

BACKGROUND MAIO OFFSET.........(BMO).... -

56 (85) # Nokia Siemens Networks DN9813196Issue 17-0 en

29/02/2008

EF - Base Control Function Handling

Page 57: NSN Zef

MAIO STEP......................(MS)..... 1 *)

BACKGROUND MAIO STEP...........(BMS).... -

MOBILE ALLOCATION FREQ LIST....(MAL).... - *)

BACKGROUND MA FREQ LIST........(BMAL)... -

UNDERLAY BTS HOPPING MODE.........(UHOP)... N (NOT HOPPING)

BG UNDERLAY BTS HOPPING MODE......(BUHOP).. -

UNDERLAY HOP SEQ NUMBER........(UHSN)... - *)

BG UNDERLAY HOP SEQ NUMBER.....(BUHSN).. -

UNDERLAY MAIO OFFSET...........(UMO).... - *)

BG UNDERLAY MAIO OFFSET........(BUMO)... -

UNDERLAY MAIO STEP.............(UMS).... 1 *)

BG UNDERLAY MAIO STEP..........(BUMS)... -

UNDERLAY MA FREQUENCY LIST.....(UMAL)... - *)

BG UNDERLAY MA FREQUENCY LIST..(BUMAL).. -

DFCA MODE ........................(DMOD)... DFCA

DFCA MA FREQ LIST(S)...........(DMAL)... 2001 2005 2007

DFCA UNSYNC MODE MA FREQ LIST..(DUMAL).. 205 *)

MAIO VALUES PER RADIO TIMESLOT:

OVERLAY TRXS:

ADM. OP.

STATE STATE FREQ RTSL0 RTSL1 RTSL2 RTSL3 RTSL4 RTSL5 RTSL6 RTSL7

TRX-001 U WO 100 BCCH

TRX-002 U WO 104

TRX-003 L BL-USR 110

TRX-004 U WO 116

THERE IS NO UNDERLAY TRX UNDER BTS

DFCA TRXS:

TRX-008 U WO 35 - - - - - - - -

TRX-009 U WO 43 - - - - - - - -

TRX-010 U WO 54 - - - - - - - -

*) NOT RELEVANT IN THIS HOPPING MODE

COMMAND EXECUTED

The execution printout of the command ZEFO:120:IOP; for NokiaMetroSite is the following:

BSC BSC-LAB 2007-10-10 12:54:32

EXTERNAL INPUT AND OUTPUT DATA:

===============================

BCF-0120: EXTERNAL OUTPUTS

-------------------------

OUTPUT 1 ....................... ON TEXT ID 2

ADDITIONAL COOLER FAN

OUTPUT 2 ....................... OFF TEXT ID -

OUTPUT 3 ....................... OFF TEXT ID -

DN9813196Issue 17-0 en29/02/2008

# Nokia Siemens Networks 57 (85)

EFO OUTPUT BASE CONTROL FUNCTION PARAMETERS

Page 58: NSN Zef

OUTPUT 4 ....................... OFF TEXT ID -

INPUT 1 ..............ROUTE: ACT

POLARITY: OPEN SEVERITY: *** TEXT ID 99

RECTIFIER MAJOR ALARM

INPUT 2 ..............ROUTE: NOT REPORT

POLARITY: OPEN SEVERITY: * TEXT ID -

INPUT 3 ..............ROUTE: NOT REPORT

POLARITY: OPEN SEVERITY: * TEXT ID -

INPUT 4 ..............ROUTE: NOT REPORT

POLARITY: OPEN SEVERITY: * TEXT ID -

INPUT 5 ..............ROUTE: NOT REPORT

POLARITY: OPEN SEVERITY: * TEXT ID -

INPUT 6 ..............ROUTE: NOT REPORT

POLARITY: OPEN SEVERITY: * TEXT ID -

INPUT 7 ..............ROUTE: NOT REPORT

POLARITY: OPEN SEVERITY: * TEXT ID -

INPUT 8 ..............ROUTE: NOT REPORT

POLARITY: OPEN SEVERITY: * TEXT ID -

INPUT 9 ..............ROUTE: NOT REPORT

POLARITY: OPEN SEVERITY: * TEXT ID -

INPUT 10 ..............ROUTE: NOT REPORT

POLARITY: OPEN SEVERITY: * TEXT ID -

COMMAND EXECUTED

The execution printout of the command ZEFO:128:IOP; for Nokia 2ndgeneration is the following:

BSC BSC-LAB 2007-10-10 12:55:32

EXTERNAL INPUT AND OUTPUT DATA:

===============================

BCF-0128: EXTERNAL OUTPUTS

-------------------------

OUTPUT 1 .......................... ON

OUTPUT 2 .......................... ON

OUTPUT 3 .......................... OFF

OUTPUT 4 .......................... OFF

OUTPUT 5 .......................... OFF

OUTPUT 6 .......................... OFF

COMMAND EXECUTED

The execution printout of the command ZEFO:6:IDE; for Nokia Talk-family is the following:

BSC BSC-LAB 2007-10-10 09:51:27

BASE CONTROL FUNCTION BCF-006 DATA

SITE TYPE ............................ D - TALK-FAMILY

ADMINISTRATIVE STATE ................. UNLOCKED

58 (85) # Nokia Siemens Networks DN9813196Issue 17-0 en

29/02/2008

EF - Base Control Function Handling

Page 59: NSN Zef

OPERATIONAL STATE .................... WO

D-CHANNEL LINK SET 5 ............. DONNA WO-EX

RX DIFFERENCE LIMIT ..........(RXDL).. 10 dB

TEST EQUIPMENT ...............(TEST).. --

BTS BATTERY BACKUP PROCEDURE .(BBU)... ALL

TRX SHUTDOWN TIMER ...........(NTIM).. 0 min

BCCH TRX SHUTDOWN TIMER ......(BTIM).. 0 min

MASTER CLOCK BCF .............(MCBCF). --

CLOCK SOURCE .................(CS).... --

SYNCHRONIZATION ENABLED ......(SENA).. F

SYNCHRONIZATION MODE .........(SM).... UNSYNCH

FACCH LAPDM T200 .............(T200F). 0 (BCF PREDEFINED VALUES)

SDCCH LAPDM T200 .............(T200S). 0 (BCF PREDEFINED VALUES)

BTS UNDER THIS BCF ARE:

BTS-006 DONNA ............... UNLOCKED

COMMAND EXECUTED

The execution printout of the command ZEFO:50:; for Nokia Flexi EDGEis the following:

BSC KANTOB95 2007-10-09 14:15:49

BASE CONTROL FUNCTION BCF-0050 DATA

SITE TYPE .......................... E – FLEXI EDGE

ADMINISTRATIVE STATE ............... UNLOCKED

OPERATIONAL STATE .................. WO

D-CHANNEL LINK SET 380 ............ OM190 WO-EX

RX DIFFERENCE LIMIT ...........(RXDL).. 10 dB

BTS BATTERY BACKUP PROCEDURE ..(BBU)... ALL

TRX SHUTDOWN TIMER ............(NTIM).. 0 min

TRX SHUTDOWN TIMER2 ...........(NTIM2). 0 min

TRX SHUTDOWN TIMER3 ...........(NTIM3). 0 min

BCCH TRX SHUTDOWN TIMER .......(BTIM).. 0 min

MASTER CLOCK BCF ..............(MCBCF). –-

CLOCK SOURCE ..................(CS).... –-

SYNCHRONIZATION ENABLED .......(SENA).. F

SYNCHRONIZATION MODE ..........(SM).... UNSYNCH

AUTOMATIC UNLOCK ALlOWED ......(AU).... T

FACCH LAPDM T200 ..............(T200F). 0 (BCF PREDEFINED VALUES)

SDCCH LAPDM T200 ..............(T200S). 0 (BCF PREDEFINED VALUES)

ABIS OVER IP ETHERNET USAGE ...(TRS1).. 1 (IN USE)

ADDITIONAL 2 E1/T1 USAGE ......(TRS2).. 2 (IN USE)

TRS ABIS GROOMING USAGE .......(TRS3).. 0 (NOT IN USE)

TRS LOOP PROTECTION USAGE .....(TRS4).. 0 (NOT IN USE)

BTS UNDER THIS BCF ARE:

BTS-0001 SECTOR-001 CITY1 ..... LOCKED

BTS-0002 SECTOR-002 CITY2 ..... UNLOCKED

BTS-0003 SECTOR-003 CITY3 ..... LOCKED

COMMAND EXECUTED

DN9813196Issue 17-0 en29/02/2008

# Nokia Siemens Networks 59 (85)

EFO OUTPUT BASE CONTROL FUNCTION PARAMETERS

Page 60: NSN Zef

Semantic errormessages

In error conditions, the general semantic error messages of the MMLcommands are output. For more information, see General NoticeMessages of MML Session.

Execution errormessages

In error conditions, the general execution error messages of the MMLcommands are output. For more information, see General Error Messagesof System.

60 (85) # Nokia Siemens Networks DN9813196Issue 17-0 en

29/02/2008

EF - Base Control Function Handling

Page 61: NSN Zef

EFL OUTPUT BASE CONTROL FUNCTIONSYNCHRONIZATION CONFIGURATIONFunction With this command you output the BCF objects synchronisation

configuration.

You can identify the BCF with the BCF number. You can also identifymultiple BCF numbers with the grouping characters & and &&. Theprogram displays the synchronisation data on those BCFs that are storedin the BSS Radio Network Configuration Database (BSDATA).

If you do not identify the BCF, the synchronisation data on all BCFs in theBSDATA is displayed.

The command is not available for the Nokia 2nd generation, NokiaPrimeSite, or Nokia InSite site types.

Parameters BCF identification: synch enabled: BSC-BSC interface failure <option>;

Syntax

EFL: [ <BCF identification> ... | <all> def ] :

[ <synch enabled> | <all> def ] :

[ BSCBSC = <BSC-BSC interface failure> <option> | <all> def ] ;

Parameterexplanations

BCF identification

With this parameter you identify the BCF with a decimal number. The valuerange depends on the BSC hardware configuration and the correspondingoptions. You can enter multiple BCFs with the grouping characters & and&&.

If you do not enter the parameter, the synchronisation data of all chainsand independent mode BCFs depending on the given parameter valuesfor synch enabled and BSC-BSC interface failure are output.

DN9813196Issue 17-0 en29/02/2008

# Nokia Siemens Networks 61 (85)

EFL OUTPUT BASE CONTROL FUNCTION SYNCHRONIZATIONCONFIGURATION

Page 62: NSN Zef

If you give this parameter, you cannot give the BSC-BSC interfacefailure parameter.

synch enabled

With this parameter you output the synchronisation data of chains orindependent mode BCFs which have the defined synchronisation status.

The values are:

Parameter Value Explanation

SENA = T Synchronisation enabled.

F Synchronisation disabled.

If you do not enter the parameter, the synchronisation data of all BCFsdepending on the given parameter values for BCF identification andBSC-BSC interface failure are output.

If you give this parameter, you cannot give the BSC-BSC interfacefailure parameter.

BSC-BSC interface failure <option>

With this parameter you output the synchronisation data and DFCA TRXsof the DFCA BTSs which have the defined BSC-BSC interface status. Thedata of a BTS is output if the DFCA mode of the BTS is STANDBY orDFCA hopping, and the BTS has the BSC-BSC interface status defined bythis parameter.

OK Output DFCA BTSs which do not suffer from a BSC-BSC interface failure.

NOK Output DFCA BTSs which suffer from a BSC-BSCinterface failure.

If you give this parameter, you cannot give the BCF identification orsynch enabled parameters.

Examples 1. Output the synchronisation data of all BCFs.

ZEFL;

2. Output the synchronisation data of BCFs 1 to 10 which havesynchronisation enabled.

ZEFL:1&&10:T;

62 (85) # Nokia Siemens Networks DN9813196Issue 17-0 en

29/02/2008

EF - Base Control Function Handling

Page 63: NSN Zef

3. Output the synchronisation data and DFCA TRXs of DFCA BTSswhich suffer from a BSC-BSC interface failure.

ZEFL:::BSCBSC=NOK;

4. Output the synchronisation data of all BCFs whose BCF chainsynchronisation is enabled.

ZEFL::T:;

Additionalinformation

In the execution printout, if the BSC-BSC interface status is 'NOK', itmeans that the BSC has noticed an inter-BSC connection failure leading toexcessive uncontrolled interference in the DFCA TRXs of the BTS due tothe lack of up-to-date knowledge on some of the remote interfering cells.As a result, the BTS is operating in an unsynchronised random frequencyhopping DFCA mode.

Executionprintouts

The abbreviations used in the execution printout are:

ABIS SYNCH= BSS synchronised using Abis

BL= blocked

BL-BCF= blocked-bcf_fault

The object is blocked out of use due to a fatal BTS-site-wide failure.

BL-BTS= blocked-bts_fault

The object is blocked out of use due to a fatal sector-wide failure on the BTS site.

BL-DGN= blocked-diagnostic

The object is blocked temporarily out of use due tobase station diagnostic activities.

BL-PWR= blocked-mains_power_fault_or_manual_power_down

The object is blocked out of use due to a mains powerfailure or manual TRX power down on the BTS site.

BL-RSL= blocked-rsl_fault

The object is blocked out of use due to a telecom AbisD-channel link disconnection.

BL-RST= blocked-reset

The logical radio network object is blocked out of usedue to the reset of the corresponding physical radionetwork equipment.

BL-SHD= blocked-shutting_down

DN9813196Issue 17-0 en29/02/2008

# Nokia Siemens Networks 63 (85)

EFL OUTPUT BASE CONTROL FUNCTION SYNCHRONIZATIONCONFIGURATION

Page 64: NSN Zef

The object will be blocked out of use within a timelimit. New call attempts are prohibited via an object inthe BL-SHD state and forced handovers are executedfor ongoing calls via the object.

BL-SU= blocked-bcsu_reset

The object is blocked out of use due to a BCSU unitreset on the BSC.

BL-SWO= blocked-file_based_plan_provisioning_activation

The object is blocked out of use due to File BasedPlan Provisioning activation.

BL-SYS= blocked-system

The radio network management function class of theBSC has blocked the logical object out of use due toongoing radio network recovery actions which aretriggered because of fatal faults in the BSS radionetwork.

BL-TRX= blocked-trx_fault

The object is blocked out of use due to a fatal TRX-wide failure on the BTS site.

BL-TST= blocked-testing

The object is blocked temporarily out of use due toradio network testing activities.

BL-USR= blocked-user

The operator has blocked the object out of use. Theadministrative state of the object is LOCKED or therelated higher-level object is LOCKED.

BL-WAC= blocked-waiting_for_autoconfiguration

The object is blocked out of use.

BSC–BSC = BSC-BSC interface status

DFCA MODE= Dynamic Frequency and Channel Allocation Mode

DFCA = DFCA Hopping

DFCA TRX= DFCA TRX status

F= false

L= locked

LMU= Location Measurement Unit

LMU-ABIS= Location Measurement Unit with Abis recovery

LMU SYNCH= BSS synchronised using Location Measurement Unit

SYNCH= synchronised

T= true

64 (85) # Nokia Siemens Networks DN9813196Issue 17-0 en

29/02/2008

EF - Base Control Function Handling

Page 65: NSN Zef

U= unlocked

UNSYNCH= unsynchronised

WO= working

WO-EX= working-executing

The execution printout of the command example 1 is the following:

BSC BSC-LAB 2007-10-10 12:28:13

SYNCHRONIZATION CONFIGURATION IN BSC:

CLOCK SYNCH SYNCH ADM OP DFCA BSC-

SOURCE ENABLED MODE STA STATE MODE BSC

================= ======== ======= ========== === ====== ======= ====

MASTER BCF-0001 LMU T SYNCH U WO

BTS-0001 U WO

BTS-0002 U WO

BCF-0002 SYNCH U WO

BTS-0003 U WO

BTS-0004 U WO

BCF-0003 UNSYNCH L BL-USR

BTS-0005 L BL-USR

BTS-0006 L BL-USR

MASTER BCF-0004 BCF F UNSYNCH U WO

BTS-0007 U WO

BTS-0008 U WO

BCF-0005 UNSYNCH L BL-USR

BTS-0009 L BL-USR

BTS-0010 L BL-USR

BCF-0006 UNSYNCH U WO

BTS-0011 U WO

BTS-0012 U WO

ALONE BCF-0008 PCM T SYNCH U WO

BTS-0013 U WO

BTS-0014 U WO

COMMAND EXECUTED

When the DFCA licence is activated, the execution printout of thecommand example 2 is the following:

BSC BSC-LAB 2007-10-10 10:35:55

SYNCHRONIZATION CONFIGURATION IN BSC:

CLOCK SYNCH SYNCH ADM OP DFCA BSC-

SOURCE ENABLED MODE STA STATE MODE BSC

================= ======== ======= ========== === ====== ======= ====

MASTER BCF-0001 LMU T SYNCH U WO

BTS-0001 U WO DFCA OK

BTS-0002 U WO OFF -

DN9813196Issue 17-0 en29/02/2008

# Nokia Siemens Networks 65 (85)

EFL OUTPUT BASE CONTROL FUNCTION SYNCHRONIZATIONCONFIGURATION

Page 66: NSN Zef

BCF-0002 SYNCH U WO

BTS-0003 U WO STANDBY NOK

BTS-0004 U WO DFCA OK

BCF-0003 SYNCH U WO

BTS-0005 U WO DFCA OK

BTS-0006 U WO DFCA NOK

ALONE BCF-0008 PCM T SYNCH U WO

BTS-0013 U WO OFF -

BTS-0014 U WO OFF -

COMMAND EXECUTED

The printout of the command example 3 is the following:

BSC BSC-LAB 2007-10-10 11:36:32

SYNCHRONIZATION CONFIGURATION IN BSC:

CLOCK SYNCH SYNCH ADM OP DFCA BSC-

SOURCE ENABLED MODE STA STATE MODE BSC

================= ======== ======= ========== === ====== ======= ====

MASTER BCF-0001 LMU T SYNCH U WO

BCF-0002 SYNCH U WO

BTS-0003 U WO STANDBY NOK

DFCA TRX-002 U WO

DFCA TRX-003 U WO

DFCA TRX-005 U WO

BCF-0003 SYNCH U WO

BTS-0006 U WO DFCA NOK

DFCA TRX-001 U WO

DFCA TRX-004 U WO

COMMAND EXECUTED

The printout of the command example 4 is the following:

BSC BELLE 2007-10-10 14:29:02

SYNCHRONIZATION CONFIGURATION IN BSC:

CLOCK SYNCH SYNCH ADM OP DFCA BSC-

SOURCE ENABLED MODE STA STATE MODE BSC

================= ======== ======= ========== === ====== ======= ====

MASTER BCF-0209 LMU-ABIS T LMU SYNCH U WO

BTS-0209 U WO OFF -

BTS-0512 U WO OFF -

BCF-0201 LMU SYNCH U WO

BTS-0201 U WO OFF -

BTS-0202 U WO OFF -

BTS-0203 U WO DFCA OK

MASTER BCF-0210 LMU-ABIS T ABIS SYNCH U WO

BTS-0210 U WO OFF -

BTS-0211 U WO OFF -

66 (85) # Nokia Siemens Networks DN9813196Issue 17-0 en

29/02/2008

EF - Base Control Function Handling

Page 67: NSN Zef

BCF-0205 ABIS SYNCH U WO

BTS-0205 U WO OFF -

BTS-0206 U WO OFF -

BTS-0207 U WO DFCA OK

COMMAND EXECUTED

Semantic errormessages

If an error occurs, the general semantic error messages of the MMLcommands are output. For more information, see General NoticeMessages of MML Session.

Execution errormessages

In error conditions, the general execution error messages of the MMLcommands are output. For more information, see General Error Messagesof System.

DN9813196Issue 17-0 en29/02/2008

# Nokia Siemens Networks 67 (85)

EFL OUTPUT BASE CONTROL FUNCTION SYNCHRONIZATIONCONFIGURATION

Page 68: NSN Zef

68 (85) # Nokia Siemens Networks DN9813196Issue 17-0 en

29/02/2008

EF - Base Control Function Handling

Page 69: NSN Zef

EFS CHANGE BASE CONTROL FUNCTIONADMINISTRATIVE STATEFunction With this command you change the BCF's administrative state.

Parameters BCF identification: administrative state;

Syntax EFS: <BCF identification> :

<administrative state> ;

Parameterexplanations

BCF identification

With this parameter you identify the BCF with a decimal number. The valuerange depends on the BSC hardware configuration and the correspondingoptions.

administrative state

With this parameter you lock or unlock the object.

U: Unlock the object.

L: Lock the object.

The parameter is obligatory.

Examples 1. Lock the BCF 128.

ZEFS:128:L;

Executionprintouts

The execution printout of command example 1 is the following:

DN9813196Issue 17-0 en29/02/2008

# Nokia Siemens Networks 69 (85)

EFS CHANGE BASE CONTROL FUNCTION ADMINISTRATIVESTATE

Page 70: NSN Zef

BSC BSC-LAB 2007-10-10 13:54:32

BASE CONTROL FUNCTION BCF-0128 STATE LOCKED

COMMAND EXECUTED

Semantic errormessages

In error conditions, the general semantic error messages of the MMLcommands are output. For more information, see General NoticeMessages of MML Session.

Execution errormessages

/*** BCSU UPDATE ERROR ***/

The state change was successful but updating one or more BCSUs failed.After this message, a list of failed BCSU updates is output, for example, inthe following form:

/*** BCSU-05 NOT UPDATED ***/

/*** BCSU-07 NOT UPDATED ***/

In addition, the general execution error messages of the MML commandsare used. For more information, see Radio Network Administration andGeneral Error Messages of System.

70 (85) # Nokia Siemens Networks DN9813196Issue 17-0 en

29/02/2008

EF - Base Control Function Handling

Page 71: NSN Zef

EFT SET BASE CONTROL FUNCTION OUTPUTSFunction With this command you modify the states of the external outputs of the

BCF object in the BSS Radio Network Configuration Database (BSDATA).

The command is not available for the Nokia PrimeSite or Nokia InSite sitetypes.

In the case of Nokia MetroSite, the number of the outputs is 4.

Parameters BCF identification: external outputs ON, external outputs OFF;

Syntax EFT: <BCF identification> :

( ON = <external outputs ON> ... |

OFF = <external outputs OFF> ... ) ... ;

Parameterexplanations

BCF identification

With this parameter you identify the BCF with a decimal number. The valuerange depends on the BSC hardware configuration and the correspondingoptions.

external outputs ON

ON = decimal number

With this parameter you define the external outputs that are set into the ONstate. You can set multiple outputs in the same command with thegrouping characters & and &&.

You must enter at least one of the parameters ON or OFF.

The default value is all outputs OFF.

external outputs OFF

DN9813196Issue 17-0 en29/02/2008

# Nokia Siemens Networks 71 (85)

EFT SET BASE CONTROL FUNCTION OUTPUTS

Page 72: NSN Zef

OFF = decimal number

With this parameter you define the external outputs that are set into theOFF state. You can set multiple outputs in the same command with thegrouping characters & and &&.

You must enter at least one of the parameters ON or OFF.

The default value is all outputs OFF.

Examples 1. Set the external outputs 1, 2, and 3 of BCF-128 to ON, and set theexternal outputs 4, 5, and 6 to OFF.

ZEFT:128:ON=1&&3,OFF=4&&6;

2. In the case of Nokia MetroSite, set the external outputs 1 and 2 ofBCF-120 to ON, and set the external outputs 3 and 4 to OFF.

ZEFT:120:ON=1&2,OFF=3&4;

Executionprintouts

The execution printout of command example 1 is the following:

BSC BSC-LAB 2007-10-10 13:54:32

BASE CONTROL FUNCTION BCF-0128 OUTPUT IS MODIFIED

OUTPUT 1 .................... ON

OUTPUT 2 .................... ON

OUTPUT 3 .................... ON

OUTPUT 4 .................... OFF

OUTPUT 5 .................... OFF

OUTPUT 6 .................... OFF

COMMAND EXECUTED

The execution printout of command example 2 is the following:

BSC BSC-LAB 2007-10-10 13:54:32

BASE CONTROL FUNCTION BCF-0120 OUTPUT IS MODIFIED

OUTPUT 1 .................... ON TEXT ID 2

ADDITIONAL COOLER FAN

OUTPUT 2 .................... ON TEXT ID 5

MAST WARNING LIGHTS

OUTPUT 3 .................... OFF TEXT ID -

OUTPUT 4 .................... OFF TEXT ID -

COMMAND EXECUTED

72 (85) # Nokia Siemens Networks DN9813196Issue 17-0 en

29/02/2008

EF - Base Control Function Handling

Page 73: NSN Zef

Semantic errormessages

/*** ERROR IN ON/OFF PARAMETER VALUES ***/

You have attempted to give the same external output number to both theON and the OFF parameter.

In addition, the general semantic error messages of the MML commandsare output. For more information, see General Notice Messages of MMLSession.

Execution errormessages

/*** BCSU UPDATE ERROR ***/

The output state change was successful but updating one or more BCSUsfailed. After this message, a list of failed BCSU updates is output, forexample, in the following form:

/*** BCSU-05 NOT UPDATED ***/

/*** BCSU-07 NOT UPDATED ***/

In addition, the general execution error messages of the MML commandsare used. For more information, see Radio Network Administration andGeneral Error Messages of System.

DN9813196Issue 17-0 en29/02/2008

# Nokia Siemens Networks 73 (85)

EFT SET BASE CONTROL FUNCTION OUTPUTS

Page 74: NSN Zef

74 (85) # Nokia Siemens Networks DN9813196Issue 17-0 en

29/02/2008

EF - Base Control Function Handling

Page 75: NSN Zef

EFX SET BASE CONTROL FUNCTIONEXTERNAL INPUT PARAMETERSFunction With this command you set BCF object's external input parameters in the

BSS Radio Network Configuration Database (BSDATA).

The command is allowed only if the site type is Nokia MetroSite, NokiaUltraSite, or Nokia Flexi EDGE.

Parameters BCF identification: external input number: route, polarity: severity, text ID;

Syntax EFX: <BCF identification> :

INBR = <external input number> :

[ ROU = <route> |

POL = <polarity> ] ... :

[ SEV = <severity> |

TID = <text ID> ] ... ;

Parameterexplanations

BCF identification

With this parameter you identify the BCF with a decimal number. The valuerange depends on the BSC hardware configuration and the correspondingoptions.

The parameter is obligatory.

external input number

INBR = decimal number

With this parameter you define the external input number. The valuesrange from 1 to 10 for Nokia MetroSite, and from 1 to 24 for Nokia UltraSiteand Nokia Flexi EDGE.

DN9813196Issue 17-0 en29/02/2008

# Nokia Siemens Networks 75 (85)

EFX SET BASE CONTROL FUNCTION EXTERNAL INPUTPARAMETERS

Page 76: NSN Zef

The parameter is obligatory.

route

With this parameter you activate the routing of the input alarm and choosewhere the alarm is sent.

This parameter defines the reporting route of external alarms of a BCF.The BCF sends alarm indications to the BSC and the NMS/2000 (ACT) orto the NMS/100 (TMS) according to the value of this parameter.

The values are:

Parameter Value Explanation

ROU = NOT Not activated (notreported).

ACT Activated, reported to theBSC as a normal externalalarm.

TMS Activated, reported as atransmission alarm to theTransmission ManagementSystem.

MAINS Activated, reported to theBSC as a MainsBreakdown alarm.

The transmission management system can be BSC, BTS, or externalmanagement system (for example NMS/10 MF).

This parameter is visible only for Nokia MetroSite, Nokia UltraSite, andNokia Flexi EDGE BTS site types.

polarity

With this parameter you define the actual polarity of the external inputconnection. In the case of state transition in the input connection, the BCFreports either the alarm or the cancel message according to the value ofthis parameter.

The values are:

Parameter Value Explanation

POL = OPEN Active when open.

76 (85) # Nokia Siemens Networks DN9813196Issue 17-0 en

29/02/2008

EF - Base Control Function Handling

Page 77: NSN Zef

Parameter Value Explanation

CLOSED Active when closed.

This parameter is visible only for Nokia MetroSite, Nokia UltraSite, andNokia Flexi EDGE BTS site types.

severity

With this parameter you define the severity of the input alarm.

The values are:

Parameter Value Explanation

SEV = AL3 The highest alarm level.

AL2 The medium alarm level.

AL1 The lowest alarm level.

If the value of the route parameter is TMS (NMS/100), parametersseverity and text ID are not relevant.

This parameter is visible only for Nokia MetroSite, Nokia UltraSite, andNokia Flexi EDGE BTS site types.

text ID

TID = decimal number

With this parameter you refer to the text string. The values range from 1 to200.

To remove the input's text ID, enter the value 0 (0 = text not defined).

If the value of the route parameter is TMS (NMS/100), parametersseverity and text ID are not relevant.

Examples 1. Set the external input number of BCF-128 to value 1 and set theparameters as follows:

route to the NMS/2000 (ACT), polarity to OPEN, and the severityclass to value AL3 with text ID 100.

ZEFX:128:INBR=1:ROU=ACT,POL=OPEN:SEV=AL3,TID=100;

DN9813196Issue 17-0 en29/02/2008

# Nokia Siemens Networks 77 (85)

EFX SET BASE CONTROL FUNCTION EXTERNAL INPUTPARAMETERS

Page 78: NSN Zef

2. Set the external input number of BCF-1 to value 10 and set theparameters as follows:

route to the NMS/100 (TMS) and polarity to OPEN.

ZEFX:1:INBR=10:ROU=TMS,POL=OPEN;

Executionprintouts

The execution printout of command example 1 is the following

BSC BSC-LAB 2007-10-10 12:54:32

EXTERNAL INPUT OF BCF-0128 MODIFIED

INPUT 1 ..............ROUTE: ACT

POLARITY: OPEN SEVERITY: *** TEXT ID 100

RECTIFIER MAJOR ALARM

COMMAND EXECUTED

Semantic errormessages

In error conditions, the general semantic error messages of the MMLcommands are output. For more information, see General NoticeMessages of MML Session.

Execution errormessages

In addition, the general execution error messages of the MML commandsare used. For more information, see Radio Network Administration andGeneral Error Messages of System.

78 (85) # Nokia Siemens Networks DN9813196Issue 17-0 en

29/02/2008

EF - Base Control Function Handling

Page 79: NSN Zef

EFR RESET BASE CONTROL FUNCTIONFunction With this command you reset the BTS site or the OMU of the BTS site.

Parameters BCF identification: reset type;

Syntax EFR: <BCF identification> :

[ <reset type> | SITE def ] ;

Parameterexplanations

BCF identification

With this parameter you identify the BCF with a decimal number. The valuerange depends on the BSC hardware configuration and the correspondingoptions.

reset type

With this parameter you define the type of the reset.

SITE The whole BTS site is reset.

OMU The OMU of the BTS site is reset.

The default value is SITE.

The reset fails if the BCF is waiting for autoconfiguration.

OMU reset is only allowed for the Nokia 2nd generation, Nokia Talk-family,Nokia UltraSite, and Nokia Flexi EDGE site types.

DN9813196Issue 17-0 en29/02/2008

# Nokia Siemens Networks 79 (85)

EFR RESET BASE CONTROL FUNCTION

Page 80: NSN Zef

Note

Operation and maintenance unit (OMU) reset fails if the base controlfunction (BCF) is in ABIS SYNCH mode or being changed into ABISSYNCH mode. The resulting error message is: INVALID OBJECTSTATE.

Examples 1. Reset the BTS site in BCF-128.

ZEFR:128;

2. Reset the OMU of the BTS site in BCF-66.

ZEFR:66:OMU;

Additionalinformation

Before executing the command, the system asks for confirmation:

THIS COMMAND CUTS ALL ONGOING CALLS IN THE RESETED BTS SITE

CONFIRM COMMAND EXECUTION: Y/N ?

Executionprintouts

The execution printout of command example 1 is the following:

BSC BSC-LAB 2007-10-10 13:54:32

BCF-0128: BTS SITE RESET STARTED

COMMAND EXECUTED

The execution printout of command example 2 is the following:

BSC BSC-LAB 2007-10-10 15:07:32

BCF-0066: OPERATION AND MAINTENANCE UNIT RESET OF THE BTS SITE STARTED

COMMAND EXECUTED

Semantic errormessages

In error conditions, the general semantic error messages of the MMLcommands are output. For more information, see General NoticeMessages of MML Session.

Execution errormessages

In error conditions, the general execution error messages of the MMLcommands are used. For more information, see General Error Messagesof System.

80 (85) # Nokia Siemens Networks DN9813196Issue 17-0 en

29/02/2008

EF - Base Control Function Handling

Page 81: NSN Zef

EFE MODIFY EXTERNAL INPUT AND OUTPUTTEXTFunction With this command you can create a text string in the BSS Radio Network

Configuration Database (BSDATA), modify it, and delete it from it.

Parameters text ID: text string;

Syntax EFE: TID = <text ID> :

TEXT = <text string>;

Parameterexplanations

text ID

TID = decimal number

With this parameter you define the text ID number of a text string. Thevalues range from 1 to 200.

The parameter is obligatory.

text string

TEXT = text string

With this parameter you define the text string. The length of the text stringmust not be more than 80 characters. The text string must be enteredinside quotation marks. The text string can include following characters:

Capital letters: A...Z

Numbers: 0...9

Characters: < > _ - / ( ) , . ! # $ @ % & * + ' = and space

DN9813196Issue 17-0 en29/02/2008

# Nokia Siemens Networks 81 (85)

EFE MODIFY EXTERNAL INPUT AND OUTPUT TEXT

Page 82: NSN Zef

You can delete a text string by leaving the text field empty inside thequotation marks. In this case the MML asks you to confirm the operation.The delete operation removes the text string connection from the BCF(s).

The parameter is obligatory.

Examples 1. Create the text ID 100.

ZEFE:TID=100:TEXT="SMOKE ALARM";

2. Delete the text ID 100.

ZEFE:TID=100:TEXT="";

Additionalinformation

Before the deletion is executed, the system asks for confirmation:

YOU ARE DELETING TEXT STRING AND REMOVING TEXT STRING CONNECTION

CONFIRM COMMAND EXECUTION: Y/N ?

Executionprintouts

The printout of command example 1 is the following:

BSC BSC-LAB 2007-10-10 13:54:32

TEXT ID 100 CREATED

SMOKE ALARM

COMMAND EXECUTED

Semantic errormessages

In error conditions, the general semantic error messages of the MMLcommands are output. For more information, see General NoticeMessages of MML Session.

Execution errormessages

In addition, the general execution error messages of the MML commandsare used. For more information, see Radio Network Administration andGeneral Error Messages of System.

82 (85) # Nokia Siemens Networks DN9813196Issue 17-0 en

29/02/2008

EF - Base Control Function Handling

Page 83: NSN Zef

EFP OUTPUT EXTERNAL INPUT AND OUTPUTTEXTSFunction With this command you output the use of the texts. The command outputs

the texts and lists the BCFs using the text.

Parameters text ID, printout format;

Syntax EFP: [ TID = <text ID> ... | <all> def |

FORM = <printout format> | SHORT def ] ... ;

Parameterexplanations

text ID

TID = decimal number

With this parameter you define the text ID number of a text string. Thevalues range from 1 to 200.

You can enter multiple text IDs with the grouping characters & and &&. Ifyou do not enter any decimal number to this parameter, all defined textsfrom the BSS Radio Network Configuration Database (BSDATA) will beoutput.

The default value is 'all'.

printout format

With this parameter you choose the type of the printout.

You choose between the long format and the short format. The differencebetween the long and short format is that the long format includes theBCFs using the text.

The values are:

DN9813196Issue 17-0 en29/02/2008

# Nokia Siemens Networks 83 (85)

EFP OUTPUT EXTERNAL INPUT AND OUTPUT TEXTS

Page 84: NSN Zef

Parameter Value Explanation

FORM = LONG Outputs the defined textincluding the BCFs usingthe text.

SHORT Outputs only the definedtext.

The default value is SHORT.

Examples 1. Output the text ID number 1 in the long format.

ZEFP:TID=1,FORM=LONG;

2. Output all the texts in the short format.

ZEFP;

Executionprintouts

The execution printout of command example 1 is the following:

BSC BSC-LAB 2007-10-10 12:54:32

INPUT AND OUTPUT TEXT(S)

TEXT ID 1

SMOKE ALARM

BCF(S) USING THE TEXT:

0001 0005 0006 0128

COMMAND EXECUTED

The execution printout of command example 2 is the following:

BSC BSC-LAB 2007-10-10 12:54:32

INPUT AND OUTPUT TEXT(S)

TEXT ID 1

SMOKE ALARM

TEXT ID 2

ADDITIONAL COOLER FAN

TEXT ID 99

RECTIFIER MAJOR ALARM

COMMAND EXECUTED

84 (85) # Nokia Siemens Networks DN9813196Issue 17-0 en

29/02/2008

EF - Base Control Function Handling

Page 85: NSN Zef

Semantic errormessages

In error conditions, the general semantic error messages of the MMLcommands are output. For more information, see General NoticeMessages of MML Session.

Execution errormessages

In addition, the general execution error messages of the MML commandsare used. For more information, see Radio Network Administration andGeneral Error Messages of System.

DN9813196Issue 17-0 en29/02/2008

# Nokia Siemens Networks 85 (85)

EFP OUTPUT EXTERNAL INPUT AND OUTPUT TEXTS