November 2010 April 2011. SATEC 25 years of Innovation in measurement & management of Energy and...

24
November 2010 April 2011

Transcript of November 2010 April 2011. SATEC 25 years of Innovation in measurement & management of Energy and...

Page 1: November 2010 April 2011. SATEC 25 years of Innovation in measurement & management of Energy and Power Quality.

November 2010

April 2011

Page 2: November 2010 April 2011. SATEC 25 years of Innovation in measurement & management of Energy and Power Quality.

SATEC25 years of Innovation in measurement & management of Energy and Power Quality

Page 3: November 2010 April 2011. SATEC 25 years of Innovation in measurement & management of Energy and Power Quality.

COMMERCIAL INDUSTRIAL UTILITIES

Generation

OEM

Semiconductors

Automotive

Mining

Process Industry

Pharmaceutical

Gas

Transmission

Distribution

Sports

Residential

Hi-TechTelecom

BanksSupermarkets /Wholesale

Universities

Transportation

Data Centers

Page 4: November 2010 April 2011. SATEC 25 years of Innovation in measurement & management of Energy and Power Quality.

RS232/422/485, Profibus, TCP/IP, Dialup modem, GPRS, RF

Modbus RTU, ASCII, DNP3.0, Modbus/TCP, DNP3/TCP, IEC 61850

ETC2002

LAN

eXpertpower™ Server (Pro Edition)

COMMERCIAL & INDUSTRIAL

Multi-Tenant Submetering

Power Measurement

Energy Efficiency & Cost Allocation

Energy Management & Billing

Asset ManagementSubstation

Automation

UTILITIES & RENEWABLEALL

Power Quality Analysis

Fault Recording

Revenue Metering

Smart Grid & Demand Response

C192PFBFM136 PM172 PM174/5 EM720 EM920 ezPAC

PAS

PM130 PLUS PM296

eXpertpower™

Internet

eXpertpower™ Server (SaaS)

The Full Range of Electricity Management Solutions for Every Application

Page 5: November 2010 April 2011. SATEC 25 years of Innovation in measurement & management of Energy and Power Quality.

Present Information, Control operations and Makes strategic

decisions

Web-based - Energy Management System

eXpertpower™

Data are highly accessible and presented to facilitate

decisions

Page 6: November 2010 April 2011. SATEC 25 years of Innovation in measurement & management of Energy and Power Quality.

eXpertpower™ Collects data from meters Analyzes the data Presents the information

using:– Dashboards– Standard Data Displays– Graphical Presentations– Interactive Graphs– Export Tools

Reacts!

Page 7: November 2010 April 2011. SATEC 25 years of Innovation in measurement & management of Energy and Power Quality.

Data Collection and Presentation

Navigation AMRData

Collection & Presentation

Rep

orts

& G

rap

hs

PowerQuality

Demand Response

EnergyEfficiency

AppsSub-

Metering

Multi-Dimension ComparisonsAnalysis

History Archiving and Display

Even

ts &

Ala

rms

Page 8: November 2010 April 2011. SATEC 25 years of Innovation in measurement & management of Energy and Power Quality.

Data Collection: Presentation

No more running to the display panel - The data comes to you

Different Measurement pages represent the various device types

Page 9: November 2010 April 2011. SATEC 25 years of Innovation in measurement & management of Energy and Power Quality.

Data Collection: Navigation

Graphic pages tailored to allow for easy navigation even in complex systems

Unique pages represent the full range of network view: from high-level overview to a specific device

Page 10: November 2010 April 2011. SATEC 25 years of Innovation in measurement & management of Energy and Power Quality.

Data Collection and Presentation

Navigation AMRData

Collection & Presentation

Rep

orts

& G

rap

hs

PowerQuality

Demand Response

EnergyEfficiency

AppsSub-

Metering

Multi-Dimension ComparisonsAnalysis

History Archiving and Display

Even

ts &

Ala

rms

Page 11: November 2010 April 2011. SATEC 25 years of Innovation in measurement & management of Energy and Power Quality.

History: Archiving and display

Use Historic data to detect trends and anomalies

Page 12: November 2010 April 2011. SATEC 25 years of Innovation in measurement & management of Energy and Power Quality.

Data Collection and Presentation

Navigation AMRData

Collection & Presentation

Rep

orts

& G

rap

hs

PowerQuality

Demand Response

EnergyEfficiency

AppsSub-

Metering

Multi-Dimension ComparisonsAnalysis

History Archiving and Display

Even

ts &

Ala

rms

Page 13: November 2010 April 2011. SATEC 25 years of Innovation in measurement & management of Energy and Power Quality.

Power Quality

View and analyze Power Quality events

Page 14: November 2010 April 2011. SATEC 25 years of Innovation in measurement & management of Energy and Power Quality.

Power Quality

Compare to EN50160 Standard

Page 15: November 2010 April 2011. SATEC 25 years of Innovation in measurement & management of Energy and Power Quality.

Sub-metering

Calculate costs of any monitored point: Charge External Users Monitor Costs

Page 16: November 2010 April 2011. SATEC 25 years of Innovation in measurement & management of Energy and Power Quality.

Energy Efficiency

Monitor Consumption

Detect Energy Loss

Page 17: November 2010 April 2011. SATEC 25 years of Innovation in measurement & management of Energy and Power Quality.

Demand Response

Make the most of utility incentives

Page 18: November 2010 April 2011. SATEC 25 years of Innovation in measurement & management of Energy and Power Quality.

Data Collection and Presentation

Navigation AMRData

Collection & Presentation

Rep

orts

& G

rap

hs

PowerQuality

Demand Response

EnergyEfficiency

AppsSub-

Metering

Multi-Dimension ComparisonsAnalysis

History Archiving and Display

Even

ts &

Ala

rms

Page 19: November 2010 April 2011. SATEC 25 years of Innovation in measurement & management of Energy and Power Quality.

Analysis: Compare on time line

Wide range of Analytical tools to compare: Time Line Locations Utility Measurements

Page 20: November 2010 April 2011. SATEC 25 years of Innovation in measurement & management of Energy and Power Quality.

What’s New in Ver. 2011 User Interface:

– Updated UI: graphics, navigation, controls, search– Customized dashboard– Support for multiple browsers: IE, Firefox, Safari

AMR:– Multithreaded single process– Enhanced connection monitoring

Security standards:– Authentication– API

Stand alone mode System API for 3rd party integration

– Web services Supports OEM branding Knowledge base web site Internal logic optimization

Page 21: November 2010 April 2011. SATEC 25 years of Innovation in measurement & management of Energy and Power Quality.

Display Screens - User Dashboard Readings:

– Last Readings– History– Max Demands– Data logs

Energy:– Total– Import– Export

Events View Report Wizard Data Entry:

– Import– Energy Diary

Page 22: November 2010 April 2011. SATEC 25 years of Innovation in measurement & management of Energy and Power Quality.

Display Screens - Admin Maintenance:

– Customers– Sites– ETCs– Devices

Permissions:– Roles– Users

Events Definition License Management System Settings

Page 23: November 2010 April 2011. SATEC 25 years of Innovation in measurement & management of Energy and Power Quality.

Software Modules

Energy Manageme

nt

Data Monitoring & Recording

Navigation

Data Views

Reports

Events and Alarms

Billing & Submeteri

ng

Cost Calculation & Monitoring

Invoice Management

Tenant Management

Additional Costs

Power Quality

Power Quality Events

Waveform Analysis 

EN50160 Reports

Generator Control

Automatic / Manual

Generator Control

Interface to Utility Load

Profiles

Page 24: November 2010 April 2011. SATEC 25 years of Innovation in measurement & management of Energy and Power Quality.

SATECEmpowering the Smart Grid

November 2010