NOT FOR CONSTRUCTION - majorprojects.planningportal.nsw.gov.au

6

Transcript of NOT FOR CONSTRUCTION - majorprojects.planningportal.nsw.gov.au

Page 1: NOT FOR CONSTRUCTION - majorprojects.planningportal.nsw.gov.au
Page 2: NOT FOR CONSTRUCTION - majorprojects.planningportal.nsw.gov.au
Page 3: NOT FOR CONSTRUCTION - majorprojects.planningportal.nsw.gov.au

R

RR

Ldry

R

R

RLd

ry

RR

Ldry

R

R

R

R

R

R

R

R

R

R

R

R

R

R

T1-7

T1-K

T1-5

T1-4

T1-3

T1-2

T1-1

T1-ET1-DT1-CT1-BT1-A

C-2-28C25.01

C-2-29C25.02 C-1-13

C25.03C-1-17C25.04

C-1-18C25.05

C-3-04C25.06

C-2-23C24.02

Study Study Study

Living

Livi

ngLivi

ng

DiningDining

Dining

Bed 1Bed 1 Bed 1

Bed 1

Bed 1

Bed 2

Study

Living

Dining

Bed 2

Bed 1

Bed 1

Bed 2

Dining

Study

Bed 2

Bed 3

Dining

Living

StoreStudy

Living

Hot Water PlantC25.14

T1-6

L01 L02 L03

6750 3000 7000 7000 7000 7000 72507500 7500

Elect CommsFire

Gas

Fire

T1-F T1-G T1-H T1-J

11001100 1100 1100

1000

1000

1000

1000

1000

1050 1050 1050 1050 1050 1050 1050 1050 1050 1000 1000 1000 1000 1100 1100 1100 1150 1150

1000

1000

1000

1000

1000

844

1150 1100 1100 1100 1050 1050 1050 10501050

10501050

10501050

10501050

983983

983

983

983

900

900

965

965

965

955

955

955

955955

9541050

10501050

843

900

900

900

900

900

900

900

1075

970970

9701088 1088 1088 1088 1050 1050 1050 1050 1050 1050 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1050 1050 1050 1050

900

1065

900900

900

900

965

1065

984

843

843

900

900

10751075

1000

1000

900

965

900900

900900

965

900

983

983

970970

Anti Throw Zone

Type A

Type B

Type B

Type C

Type C

1225

1225

1455

W08

W02

W08

W02

W03

W01

W08

W01

W13

700

W19

W04

W08

1150 1150

W05

W07

W13

W10

W16 W10

W01

5000

1115

018

0038

0082

5050

00

20M Setback (From Boundary)

1000

800

8021000 1000

770

1100

1100

10001000

499

1100

1100

1000

1100

1100

1000 1000

1150 1150

10001000

1000

1000

1000

1000

29012251225

1000534

1000

1000

260

1100110011001100801

Gas NBN

GarbageExhaust

KitchenExhaust

Kitchen2/A17-101

Kitchen1/A17-112

Kitchen1/A17-112

Kitc

hen

2/A

17-1

04

Kitc

hen

1/A

17-1

01

Ens1G/A15-101

Bath2/A15-112

Ens1F/A15-101

Bath1/A15-112

Bath2/A15-104

Bath3A/A15-107

Bath4/A15-107

Bath1/A15-103 Ens

1I/A15-101

Bath3A/A15-112

Ldy2/A15-113

Kitchen1/A17-111Store

Lobby Relief Air Shaftto L23 [high level]

1000

4000

1200

6000

1000

1000

800

1100

1000

600

839

AdaptableUnit

AdaptableUnit

695905

894

896

890716

NOTE:UNIT C25.06 & C25.07SUBJECT TO VARIATIONDIRECTION 072.Refer to drawing A60.006

NOTE:UNIT C24.02 IS SUBJECT TOVARIATION DIRECTION VD018.Refer to drawing A60-015

EX.S

150

EX

.S

EQ EQ

CL

EX

.S

100

EX.S

150

EX

.S

100CL

EX.S

150

C L

Additional HC & GPOas per VD072.Setout as per typicalvertical arrangement.

EX

.S

CL

Min.

1000

All external service pointsto be located 1m [laterally]from balustrade.

100AFS ColumnBelow

Lobby S/A To Level 23and L24

2738

718

2535

CL1250 1250

C L

1000

1000

1091

1024

1049

12391239

1320

1225

1413 950

1100

1319

1050

AwningWindow

400mm droppanel below

988 616

UnitC25.08

UnitC25.09

Bed 1Dining

Kitchen

Living

Bed 2

Bed 3

Bath

Ens

Dining

Living

Kitchen

Bed 2Bed 1

Bath

Ens

LEGEND - ELECTRICAL & SERVICES

Single GPO, generally mounted 300mm AFFL to centreline

Double GPO, generally mounted 300mm AFFL to centreline. Refer tonotes below

AB, denotes GPO above benchtop, mounting height varies, refer to joinery andwet area drawings for exact locationCT, denotes GPO to cooktop, mounted 500mm AFFL to centrelineDR, denotes GPO to conbined washing machine/dryer, mounted 500mm AFFL tocentrelineDW, denotes GPO to dishwasher, mounted 500mm AFFL to centrelineE, denotes Waterproof GPO to balcony. Mounting height TBCEX, denotes GPO to range (exhaust) hood, mounting height to suitFR, denotes GPO to fridge, mounted 1500mm AFFL to centrelineMW, denotes GPO to microwave, mounting height varies, refer to joinery drawingsfor exact locationOV, denotes GPO to oven, mounted 500mm AFFL to centreline

Telephone outlet, generally mounted 300mm AFFL to centreline, with theexception when mounted adjacent IC, see below

Intercom, mounted 1000mm AFFL to centreline

Pay TV outlet, mounted 300mm AFFL to centreline

TV outlet, mounted 300mm AFFL to centreline

Note:- GA plans to be read in conjunction with services consultants drawings, PPR document, MGACreport, wet area and joinery detailed drawings and A15-180 & A15-181 drawings- Placement of services within adaptable units to be in accordance with MGAC report and A15-180& A15-181 drawings- Services required for AC TBC- When outlets are located within wardrobe joinery, wet areas and kitchens contractor is to refer toA15 and A17 series drawings for exact location for mounting

Hose Cock, mounting height TBC. Chrome finish

Gas bayonet, mounting height TBC. Chrome finish

LEGEND - FLOOR FINISHES

Note:- Refer to finishes schedule produced by Ecove for exact schemes/finishes to units- Allow for stone thresholds at entrance and wet area door thresholds- PA-01 paint finish to all walls within units- Finishes to lobbies TBC- Refer to drawings A15-180 and A15-181 for additional finish requirements for adaptable units

CP-01 General carpet finish to units. Floor finish to continue into robes and storage cupboardsTL-01 Tile to balconyTL-02 Tile to kitchen, note format variesTL-03 Tile to wet areas . Floor finish to continue beneath laundry joinery/washing machine and

where storage cupboards are located within wet areas

GENERAL NOTESNote:- Refer to drawing series A17 for typical store and wardrobe layouts.- Top line denotes unit number, buttom line denotes unit type (including tower and number of beds)

- Top line denotes room type, bottom line denotes drawing reference for wet area / joinery- Stone thresholds to wet areas to be constructed as per details on sheets 4/A15-115 + 8/A15-115- Penthouse apartments to have tile setdown to shower as per detail 5/A15-115

C##.##C-#-##

Bath1/A15-102

FFL

HCGB

GPO

LEGEND - BALCONY SERVICE POINTS

800

Typical vertical arrangement

GPO General Power OutletHC Hose CockGB Gas BayonetFFL Finished Floor Level

EX.S Setout location for typical vertical arrangement

300

200

300

C D

Drawing no.

Pty Ltd ABN 70 004 999 400Bates Smart

Check all dimensions and site conditions prior to commencement of any work, the purchase or ordering of anymaterials, fittings, plant, services or equipment and the preparation of shop drawings and or the fabrication ofany components.

Do not scale drawings - refer to figured dimensions only. Any discrepancies shall immediately be referred tothe architect for clarification.

All drawings may not be reproduced or distributed without prior permission from the architect.

@ B1

NOT FOR CONSTRUCTION 43 Brisbane StreetSurry Hills NSW 2010 AustraliaT 02 8354 5100 F 02 8354 5199email [email protected]://www.batessmart.com.au

1 Nicholson StreetMelbourne VIC 3000 AustraliaT 03 8664 6200 F 03 8664 6300email [email protected]://www.batessmart.com.au

Sydney Melbourne

Plot File

Plot Date

Status

Project no.

Drawn

Scale

Revision

Checked

1/07/2014 5:55:02 PM

c:\temp\Site3_Homebush_ARCH_2013_CHE2.rvt

1 : 100

24

Site 3 - Australia Towers IISydney Olympic Park

GA Plan - C - Level 24 S11202

MD/MS

A03-124

TJM

For all Tower C Wall Type, refer to Wall Schedule A28.001, A28.002, A28.003For all Tower C Window Type, refer to Window Schedule A22.001, A22.002For all Adaptable Units, refer to drawings A15.18xFor all Variation Directions, refer to drawings A60.xxx

Revision Date Description Initial Checked8 02.08.13 Issue For Coordination Tower C TJM EC9 09.09.13 Issued For Review TM EC10 26.09.13 For Review TJM EC11 25.11.13 Issued For Coordination TM EC12 17.12.13 Issue For Coordination JT/TJM EC13 10.02.14 Issue For Information EM MD14 17.02.14 Issue For Coordination JT EC15 24.02.14 Variation update TJM EC16 06.03.14 Issue For Coordination JT EC17 27.05.14 Issue For Coordination JT EC18 04.06.14 Issue For Review JT EC19 13.06.14 Issue For Coordination JT EC20 17.06.14 Issue For Coordination JT EC21 19.06.14 Issue For Coordination JT EC22 27.06.14 Submission For S75W JT EC23 30.06.14 Issue For Coordination JT EC24 01.07.14 Issue For S75W JT ECNotes:

• Addtional apartment units - C25.08 and C25.09

Page 4: NOT FOR CONSTRUCTION - majorprojects.planningportal.nsw.gov.au

R

R

Ldry

R

R

T2-6

T2-5

T2-4

T2-3

T2-2

T2-A T2-C T2-D T2-F T2-G T2-H T2-J T2-KT2-B T2-E

2500

Void

Void belowUnit D30.04

Void belowUnit D30.01

PoolPlant

Void

OUTLINE OF POOL AT L30 PENTHOUSEOUTLINE OF POOL AT L30 PENTHOUSE

Typ

e A

Type BType C

Type B Type C

1050

1050105095095094510501050

10501025

10251025

10251025

1025

1100

1100

900

900

900

900

900

900

900

900

900

900

900

1050 1050 1050 10501050 1050 1050 1050

1100 1100

10501050

1050950

950950

950950

950

950

950

950

950

953

900

900

900900

11001025

1050 945 950 950 1000 1050

950

950

105010501050105010931095

10951095

10501050

10501075

1075

1075

965

965

965

965

10501050

1050

1000

1000

1000

1000

965

945

945

945

945

945926

874

859

1050 1050 1075 1065 1065 1065 1050 1050 1050 1050 870 870870

870950

950950

950950

950950

950

965

965

965

965

965965

965

950

950

10501100

11001050

1080 1050

FHR

LobbyReliefShaft

925

1200

GasFireElectNBNComms

KitchenExhaust

GarbageExhaust

1115

018

0038

0082

50

Fire RatedEquipment Hatch

[1600x1200]

FFL. 114.640 m

SSL. 114.500 m

LobbyS/A

2SK-362

3SK-361

Hot WaterPlant Room

1SK-362

Communal Area[Indoor]

Communal Area[Outdoor]

RoomD31.01

Bed 3Dining

LivingBed 2

Bed 1

Ensuite

Bath

Study/Store

AW

AW

AW

Kitchen1/A17-206

FFL. 114.640 m

2000

AW

800

877

1750

113 m2

27 m2

Skylignt over Level 30 Common114500

Level 31119000

T2-6T2-5T2-4

Level 30116250

RL. 121.090 m

1830

260

1SK-362

RL. 120.050 mRL. 120.400 m

1140

RL. 123.590 m

RL. 114.500 m

T2-5

T2-4

T2-3

T2-A T2-C T2-D T2-F T2-G T2-H T2-J T2-KT2-B T2-E

SSL. 119.260 m

1800

3800

7625 6625 7000 7000 7000 3000 7500 7500 6750

SSL. 123.590 m

SSL. 120.395 m

HOLD : Floor plan subject to strctural imput

Skylight

Skylight

C D

Drawing no.

Pty Ltd ABN 70 004 999 400Bates Smart

Check all dimensions and site conditions prior to commencement of any work, the purchase or ordering of anymaterials, fittings, plant, services or equipment and the preparation of shop drawings and or the fabrication ofany components.

Do not scale drawings - refer to figured dimensions only. Any discrepancies shall immediately be referred tothe architect for clarification.

All drawings may not be reproduced or distributed without prior permission from the architect.

@ B1

NOT FOR CONSTRUCTION 43 Brisbane StreetSurry Hills NSW 2010 AustraliaT 02 8354 5100 F 02 8354 5199email [email protected]://www.batessmart.com.au

1 Nicholson StreetMelbourne VIC 3000 AustraliaT 03 8664 6200 F 03 8664 6300email [email protected]://www.batessmart.com.au

Sydney Melbourne

Plot File

Plot Date

Status

Project no.

Drawn

Scale

Revision

Checked

DA

28/07/2014 1:09:35 PM

c:\temp\Site3_Homebush_ARCH_2013_CHE2.rvt

1 : 100

5

Site 3 - Australia Towers IISydney Olympic Park

Tower D - Level 30 - Additional Unit S11202

Checker

SK-361

Author

1 : 100SK-361

Tower D - Level 30 Additional Unit1

1 : 100SK-361

Section XX3

1 : 100SK-361

GA Plan - D - ROOF2

Revision Date Description Initial Checked1 23.06.14 Issue For Review JT EC2 24.06.14 Issue For Review JT EC3 25.06.14 Issue For review JT EC4 25.06.14 Issue For Review JT EC5 27.06.14 Submission For S75W JT EC

Notes:

Page 5: NOT FOR CONSTRUCTION - majorprojects.planningportal.nsw.gov.au

Level 29111300

Level 30 Common114500

Level 31119000

T2-A T2-C T2-D T2-F T2-G T2-H T2-J T2-KT2-B T2-E T2-KT2-A T2-C T2-D T2-F T2-G T2-H T2-JT2-B T2-E

Level 30116250

DA Approved Lift Over Run Height

RL. 123.590 m

RL. 120.400 m

UnitHot Water PlantD31.54

Lift motor Room

200

2300

300

1530

Proposed Lift Over Run Height

1140

RL. 119.260 m

Level 29111300

Level 30 Common114500

Level 31119000

T2-A T2-C T2-D T2-F T2-G T2-H T2-J T2-KT2-B T2-E T2-KT2-A T2-C T2-D T2-F T2-G T2-H T2-JT2-B T2-E

Level 30116250

7DD09-253

1SK-207

RL. 119.260 m

RL. 120.050 m

RL. 123.590 m

DA Approved Lift Over Run Height DA Approved Facade Height

Lift MotorRoom

2810

RL. 119.260 m

2300

300

6150

3190

1235

2750

1750

3200

1050

RL. 116.250 m

3

1531

DA Approved Facade HeightRL. 120.050 m

RL. 123.590 m

RL. 120.400 m

Proposed Lift Over Run Height

4590

5430

C D

Drawing no.

Pty Ltd ABN 70 004 999 400Bates Smart

Check all dimensions and site conditions prior to commencement of any work, the purchase or ordering of anymaterials, fittings, plant, services or equipment and the preparation of shop drawings and or the fabrication ofany components.

Do not scale drawings - refer to figured dimensions only. Any discrepancies shall immediately be referred tothe architect for clarification.

All drawings may not be reproduced or distributed without prior permission from the architect.

@ B1

NOT FOR CONSTRUCTION 43 Brisbane StreetSurry Hills NSW 2010 AustraliaT 02 8354 5100 F 02 8354 5199email [email protected]://www.batessmart.com.au

1 Nicholson StreetMelbourne VIC 3000 AustraliaT 03 8664 6200 F 03 8664 6300email [email protected]://www.batessmart.com.au

Sydney Melbourne

Plot File

Plot Date

Status

Project no.

Drawn

Scale

Revision

Checked

DA

27/06/2014 3:48:26 PM

c:\temp\Site3_Homebush_ARCH_2013_TAA.rvt

1 : 100

2

Site 3 - Australia Towers IISydney Olympic Park

Tower D - Roof Sections S11202

Checker

SK-362

Author

1 : 100SK-362

Tower D Lift Motor Room Section11

1 : 100SK-362

Tower D Lift Motor Room Section2

Revision Date Description Initial Checked1 23.06.14 Issue For Review JT EC2 27.06.14 Submission For S75W JT EC

Page 6: NOT FOR CONSTRUCTION - majorprojects.planningportal.nsw.gov.au

C D

Drawing no.

Pty Ltd ABN 70 004 999 400Bates Smart

Check all dimensions and site conditions prior to commencement of any work, the purchase or ordering of anymaterials, fittings, plant, services or equipment and the preparation of shop drawings and or the fabrication ofany components.

Do not scale drawings - refer to figured dimensions only. Any discrepancies shall immediately be referred tothe architect for clarification.

All drawings may not be reproduced or distributed without prior permission from the architect.

@ B1

NOT FOR CONSTRUCTION 43 Brisbane StreetSurry Hills NSW 2010 AustraliaT 02 8354 5100 F 02 8354 5199email [email protected]://www.batessmart.com.au

1 Nicholson StreetMelbourne VIC 3000 AustraliaT 03 8664 6200 F 03 8664 6300email [email protected]://www.batessmart.com.au

Sydney Melbourne

Plot File

Plot Date

Status

Project no.

Drawn

Scale

Revision

Checked

DA

27/06/2014 3:50:34 PM

c:\temp\Site3_Homebush_ARCH_2013_TAA.rvt

2

Site 3 - Australia Towers IISydney Olympic Park

Tower D - Roof Views S11202

Checker

SK-363

Author

SK-363

Tower D - Roof 021

SK-363

Tower D - Roof 012

Revision Date Description Initial Checked1 23.06.14 Issue For Review JT EC2 27.06.14 Submission For S75W JT EC