NortherN sales office D-24955 harrislee Multifunction ... · ISO certificate Compressed air...

8
www.cs-instruments.com NORTHERN SALES OFFICE Am Oxer 28c D-24955 Harrislee FON: +49 (0) 46 700 20 25 FAX: +49 (0) 46 700 20 26 EMAIL: [email protected] WEB: www.cs-instruments.com SOUTHERN SALES OFFICE Zindelsteiner Straße 5 D-78052 VS-Tannheim TEL: +49 (0) 7705 97 89 9-0 FAX: +49 (0) 7705 97 89 9-20 EMAIL: [email protected] USB SPECIAL FEATURES • Graphic evaluation of actual consumption, leakage, pressure, dew point, current consumption • Cost calculation of leakage and compressed air contsumption • User-specific analysis: Which plant uses how much compressed air? Multifunction Measuring Instrument DS 300 for Compressed Air and Gases bar m³/h °Ctd A

Transcript of NortherN sales office D-24955 harrislee Multifunction ... · ISO certificate Compressed air...

Page 1: NortherN sales office D-24955 harrislee Multifunction ... · ISO certificate Compressed air analysis with leakage calculation Meas. period 31.12.2006 until 31.01.2007, meas. rate

www.cs-instruments.com�

NortherN sales officeam oxer 28c D-24955 harrislee

foN: +49 (0) 46� 700 20 25 fax: +49 (0) 46� 700 20 26email: [email protected]: www.cs-instruments.com

southerN sales officeZindelsteiner straße �5 D-78052 Vs-tannheim

tel: +49 (0) 7705 97 89 9-0 fax: +49 (0) 7705 97 89 9-20email: [email protected]

USB

Special featUreS

• Graphicevaluationofactual consumption,leakage,pressure,dewpoint, currentconsumption

• Costcalculationofleakageandcompressed aircontsumption

• User-specificanalysis:Whichplantuseshow muchcompressedair?

MultifunctionMeasuringInstrumentDS 300forCompressedAirandGases

bar

m³/h

°ctd a

Page 2: NortherN sales office D-24955 harrislee Multifunction ... · ISO certificate Compressed air analysis with leakage calculation Meas. period 31.12.2006 until 31.01.2007, meas. rate

www.cs-instruments.com2

StationaryflowandconsumptionmeasurementVA300withmultifunctionmeterDS 300

technical Data DS 300

Technicaldataconsumptionprobepleaseseepage6

Dimensions: 92x92x55mm,IP65 (panelmounting)

inputs: 2digitalinputsfor VA300resp.FA300

interface: USB,CSdatacollector

Keypad: 4keys

Power supply: 90-260VAC,50-60Hz

accuracy: Seesensordatapage6

alarm outputs: 2relays,230VAC,3A

analogue output: 2x4...20mA

application temp.: 0...50°C

transport temp.: -20...70°C

OptiOnS

Wall housing: 118x115x93mm,IP65

Data logger: 500,000measuringvalues start-/stopzeit,measuring ratefreelyadjustable

rs 485: upto256xDS300, connectable,evaluationat PCviaCSSoftingraphicand tableform2 additional inputplug-in cards: 4-20mA,0-10V,Pt100,TC

Stationaryconsumptionmeasurement,availablewithandwithoutmeasuringsection

• Forpanelmounting (96x96mm)

• Forwallmounting • Easywallmounting

Therighthousingforeachapplication:

all-in-one measuring stationreadyforplug-in,consistingof

• Measuringsection• MultifunctionmeterDS300• ConsumptionprobeVA300

Special featUreS• All-in-onesolution,easyinstallation

• 2displays:Actualflowandtotalair consumption

• Easyinstallationandremovalofthe sensorunderpressure

• Highestaccuracydueto5point calibration

• Output4to20mAform³/h,pulse outputform³

• Easytohandle: -Innerdiameterfreelyadjustable inDS300 -2alarmvaluesfreelyadjustable -Opticaldisplayincaseofalarm -Consumptioncounterresettable

Page 3: NortherN sales office D-24955 harrislee Multifunction ... · ISO certificate Compressed air analysis with leakage calculation Meas. period 31.12.2006 until 31.01.2007, meas. rate

www.cs-instruments.com�

Data recording and evaluation atthePC–upto256 flow stations

Special featUreS:• Upto256flowstationsconnectablevia RS485

• Upto500,000measuringdataare storedineachsingleinstrumentDS300

• Onlinereadoutofthedataofeach measuringsiteatthePC(currentflowin m³/h,totalairconsumptioninm³)

• ReadoutofthedataviaCSUSB datacollector,upto64xDS300 (128MB)

• ReprogrammingofDS300viaCSUSB datacollector

cOmplete flOw StatiOn withOUt Data lOgger anD rS 485 with meaSUring SectiOn

(pleaSe See pictUre page 2) OrDer nO.

DN6 upto85 l/min 06010060

DN15 upto750 l/min 06010061

DN20 upto85 m³/h 06010062

DN25 upto140 m³/h 06010063

DN32 upto260 m³/h 06010064

DN40 upto360 m³/h 06010065

DN50 upto600 m³/h 06010066

DN65 upto1,100 m³/h 06010067

DN80 upto1,600 m³/h 06010068

DN100 upto2,700 m³/h 06010069

DN125 upto4,000 m³/h 06010070

DN150 upto5,800 m³/h 06010071

DN200 upto8,800 m³/h 06010072

acceSSOrieS OrDer nO.

OptionDS300withdataloggerfor 05003100500,000measuredvalues

OptionDS300withRS485and 05003200dataloggerfor500,000

CSdatacollectorforreadingout 05547000upto64xDS300andforreprogramming

Basicsoftwareforeasyconfiguration 05992000oftheflowstation

CSSoftProfessional, 05547010dataevaluationingraphicandtableformwithUSBcable

CSSoftProfessionalRS485, 05547020dataevaluationingraphicandtableformwithRS485/USB

5pointprecisioncalibrationwith 32000001ISOcertificate

Pleasetakeorderdetailsandfurtheraccessoriesfromthepricelist

• USBinterfaceandCSdatacollector

• CS-Softforevaluationin graphicandtableform

USB

rS 485

Page 4: NortherN sales office D-24955 harrislee Multifunction ... · ISO certificate Compressed air analysis with leakage calculation Meas. period 31.12.2006 until 31.01.2007, meas. rate

www.cs-instruments.com4

CompressedairanalysiswithDS 300ThemultifunctiondisplayDS 300givestheuserasurveyonthewholecompressedairnet

Graphicevaluationofallrelevantdata

Allrelevantmeasuringdataforaneconomicoperationofthecompressedairlineataglance:

• Actualairconsumptioninm³/h orm³/min

• Totalairconsumptioninm³

• Pressuredewpointin°Ctd

• Linepressureinbar

• CurrentconsumptioninA

• Temperaturein°C

ThedatatransfertothePCiseffected:

• bymeansoftheCSdatacollector

(manually)

•viaUSBinterfaceforshortdistancePC todisplayDS300

• viaRS485interfaceforlongdistances

TheCSdatacollector(USB)isableto:

• readoutupto64xDS300atthePC

• evaluatedataintheCSSoftProfessional

• reprogramDS300

technical Data

Consumptionprobe:pleaseseepage6

MultifunctiondisplayDS300:pleaseseepage2

clamp-On ammeter:

measuring range: 0 to 500 a

accuracy: ± 0.5 %

Dew pOint prOBe fa 300-2:

measuring range: -80 to 20 °ctd

accuracy: ± 2 °ctd at -40 °ctd

preSSUre prOBe:

measuring range: 0 to �6 bar

accuracy: ± 0,5 %

USB

cS-BUS(rS-485)

alarm relay

4 ... 20 ma output

bar

Page 5: NortherN sales office D-24955 harrislee Multifunction ... · ISO certificate Compressed air analysis with leakage calculation Meas. period 31.12.2006 until 31.01.2007, meas. rate

www.cs-instruments.com5

cS Soft professionalwithleakagecalculationThedatacollectedinDS300canbeevalu-atedbymeansofthenewlydeveloped cS Soft professional with leakage calcula-tion whichwasespeciallydevelopedforthecompressedairbranch.

1. Howisleakagedetermined? Theeasiestwayistheleakagedeter- minationonproduction-freedays, e.g.weekends,holidays,attheendof ashift.Duringthistimethecompressor carriescompressedairwhichisre- quiredtokeepaconstantpressure. Accordingtostatisticsevenifproduc- tioniseffecteddayandnightthereis atleastoneshortperiodoftimeduring whichallloadisswitchedoff,e.g. maintenancetimes.

Thisperiodoftimeisdeterminedauto- maticallybytheCSSoftProfessional.

2.Whathastobedonebytheuser? Theuserhastoenterthefollowing parameters: -CurrentcostsperkWh -Meas.rate,durationofmeasurement

3.Whichevaluationsdoestheuserget? Apartfromthegraphicevaluationwith curveprogressionsofallmeasured datathecustomerwillgetinformationon:

-thetotalairconsumptioninm³ -theleakageintotalinm³and%ofthe totalairconsumption -thecurrentconsumptioninkWh -costsperm³ofproducedcompressed airin€ -costsoftheleakagein€ -pressureprogression -pressuredewpointprogression

Pleasetakeorderdetailsandfurtheraccessoriesfromthepricelist

cOmplete flOw StatiOn

with meaSUring SectiOn: OrDer nO.

DN6 upto85 l/min 06010160

DN15 upto750 l/min 06010161

DN20 upto85 m³/h 06010162

DN25 upto140 m³/h 06010163

DN32 upto260 m³/h 06010164

DN40 upto360 m³/h 06010165

DN50 upto600 m³/h 06010166

DN65 upto1,100 m³/h 06010167

DN80 upto1,600 m³/h 06010168

DN100 upto2,700 m³/h 06010169

DN125 upto4,000 m³/h 06010170

DN150 upto5,800 m³/h 06010171

DN200 upto8,800 m³/h 06010172

acceSSOrieS OrDer nO.

OptionDS300withRS485and 05003220dataloggerfor500,000measuringvalues,incl.2additionalplug-incards

CSdatacollectorforreadingoutand 05547000programmingupto64xDS300

Basicsoftwareforeasy 05992000configurationofDS300

CSSoftProfessional,dataevaluation 05547010ingraphicandtableformwithUSBcable

CSSoftProfessionalRS485,data 05547020evaluationingraphicandtableformwithcableRS485/USB

CScompressedairanalysissoftware 05992010forleakageandcostcalculation

Clamp-onammeter0to500A 05540500

FA300-21,pressuredewpointprobe 06993024from-80to+20°Ctd

Pressureprobefrom0to16bar 06941886

5pointprecisioncalibrationwith 32000001ISOcertificate

CompressedairanalysiswithleakagecalculationMeas.period31.12.2006until31.01.2007,meas.rate1second

cOmpreSSeD air cOnSUmptiOnTotalconsumption: Averageconsumption: Maximumconsumption:

1,309,013m³ 1,805m³/h 2,400m³/h

leakageLeakageintotal: Averageleakage: Leakagerate:

299,000m³ 415m³/h 23%

energy DataTotalenergyconsumption: Energycosts: Energycostsperm³:

129,000KWh 129,000KWhx0.11€=14,190€ 14,190€/1,309,013m³

=0.011€/m³

fUrther meaSUring DataMaximumpressure: Minimumpressure: Averagevalue:

7bar 5.8bar 6bar

Maximumdewpoint: Minimumdewpoint:

-11°Ctd -50°Ctd

leakage costs: 299,000 m³ x 0.011 € = 3,289 € for 1 month

DeScriptiOn:

completely wired plug-in flow station consisting of:DS300(withdataloggerfor500,000measuredvalues),currentairconsumptioninm³/h,totalconsump-tioninm³including2additionalplug-incards(4-20mA,0-10V,Pt100,TC)ConsumptionprobeVA300-80standardversion,meas.sectionsfromDN6toDN200

Page 6: NortherN sales office D-24955 harrislee Multifunction ... · ISO certificate Compressed air analysis with leakage calculation Meas. period 31.12.2006 until 31.01.2007, meas. rate

www.cs-instruments.com6

MultifunctionMeasuringInstrumentDS 300forCompressedAirandGases

Special featUreS• Internaldatamemory

• Innerdiameteradjustableinhand-held instrument

• Easyinstallationandremovalofthe sensorunderpressurevia1/2”ballvalve

• 4hourspowerindependent measurements

technical Data

mOBile cOnSUmptiOn prOBe Va 300:

measured variables: m/s,m³/hbzw.m³/min,l/min

inner diameter freely adjustable in cs 2�90-5

Data memory: 6.000measuredvalues

Principle of meas.: calorimetricmeasurement

measuring medium: Air,gas

measuring range: 0...26.400m³/h

(seetablebelow) accuracy without measuring section: ±4%m.v.,±3%m.v.with

5pointISOprecisioncertificate

application temp.: -30upto110°Cprobetube -30upto80°Chousing

operating pressure: upto50bar

Probe tube: stainlesssteel,1.4301 totallengthstandard 220mm,Ø9mm

screw thread: G1/2”

Power supply: hand-heldinstrum.12VDC

StatiOnary cOnSUmptiOn prOBe Va 300-80:

additionally to the above mentioned data:

VariablesfreelyselectableinDS300:m³/s,m³/h,m³/min,l/minl/sec,ft/min,cfm

Diameter freely adjustable in Ds �00

accuracy with measuring section:±3%m.v.,±2%m.v.with5pointISOprecisioncertificate

Power supply: 12-30VDC

flOw meaS. rangeS mOBile + StatiOnary

standard max

Inch mm VA300-80 VA300-120 Unit

VA300-81 VA300-121

1/4” 6,0 0.8...85 1.0...120 l/min

1/2” 16,1 2.5...750 3.5...1,100 l/min

3/4” 21,7 0.3...90 0.4...120 m³/h

1” 27,3 0.5...150 0.6...200 m³/h

11/4” 36,0 0.9...280 1.2...350 m³/h

11/2” 41,8 1.2...370 1.5...500 m³/h

2” 53,1 2...600 2.5...800 m³/h

21/2” 68,9 3.5...1,100 5...1,500 m³/h

3” 84,9 5...1,600 7...2,200 m³/h

4” 110,3 9...2,700 12...3,600 m³/h

5” 133,7 13...4,000 18...5,300 m³/h

6” 162,3 18...5,800 25...8,000 m³/h

8” 200 26...8,800 33...11,700 m³/h

10” 250 40...13,700 52...18,900 m³/h

12” 300 60...19,800 80...26,400 m³/haccordingtoDIN1945,ISO1217relatedto20°C,

1000mbar

DeScriptiOn OrDer nO.mobile set for consumption measurement (max. version) consisting of: 0600 �0�0

CS2390-5mobilehand-heldinstr. 05602395

3measuringchannels

Rechargeablebatterypackforlong- 05151002

termmeasuringapprox.4hours

Mainsadapter12VDC230VAC 23902290

Portableconsumptionprobe 33000121VA300-121forCS2390-5,max.versionwith2mcabletoCS2390-5,includingcertificate

CSSoftSoftwarefordisplayingraphic 32001101

ortableform

PCconnectioncableV24RS232 23901909

USBRS232adapter 32001013

Professionaltransportcase 05546000

further accessories, not included in the set:

5pointprecisioncalibrationwith 32000001ISOcertificate

Mobilepressuredewpointprobe 06993003(-80to+50°Ctd)incl.meas.chamber,2mcabletoCS2390-5

Pleasetakeorderdetailsandfurtheraccessoriesfromthepricelist

Page 7: NortherN sales office D-24955 harrislee Multifunction ... · ISO certificate Compressed air analysis with leakage calculation Meas. period 31.12.2006 until 31.01.2007, meas. rate

www.cs-instruments.com7

lD 300 Ultrasonic leak Detector

cOSt SaVing

Inloudproductionandmachinehallsleakagescanonlybeheardiftheyhaveadiameterof1mmandmore.1holewithdiameter1mm=270EUR/yearLD300willbeamortizedafter4leakages.

Ultrasonic detector withlaser

applicatiOnSDeterminationofleakagesat:• Compressedairlines,gas,vapourandvalcuumplants• Refrigeratingplants• Doorseals

technical Data

Working frequency: 40kHz±2kHz

connections: 1)4-poleconnectionfor headsetandbatterycharger

2)3.5mmstereosocketfor sensorandcableconnection

laser: Wavelength:655upto660nm Outputpower:0.4upto0.5mW

energy supply: InternalNiMHbattery

operating duration: approx.6hourswithoutlaser approx.4hourswithlaser

charging time: approx.1.5hours

application temp.: 0°Cupto+40°C

storage temperature: -10°Cupto+50°C

telescope: 3x120cm

DeScriptiOn OrDer nO.

lD �00 ultrasonic detector set consisting of: 060� 0�0�

LD300Ultrasonicdetector 05600102

Ultrasonicsensor 06050001

Noiseisolatedheadset 05540102

Focustubewithfocustip 05300101

Cabletodetachsoundprobefrominstrument 05530101

Batterycharger 05540001

Transportcase 05540101

accessory - not included in the set:

Ultrasonictonegenerator 05540103

Telescopeextension3x120cm 05300102

BymeansofLD300leakagesinanultrasonicrangecanbedetectedwithoutanyproblemseveniftheyhaveadiameterfromapprox.0.1mm.Thetelescopicextensionisperfecttofindleakagesinpipelinesuptoaheightof6m.

Special featUreS:• Preciselocatingbymeansoflaser• Focustubeavoidsinfluencebyambientnoise• Noiseisolatedheadset

Page 8: NortherN sales office D-24955 harrislee Multifunction ... · ISO certificate Compressed air analysis with leakage calculation Meas. period 31.12.2006 until 31.01.2007, meas. rate

www.cs-instruments.com8

Usefulaccessories,measuring sections

1. Measuringsectionsforprecisemeasurements,from Dn 80 with Din flange connection

2.Whatifno1/2” ball valve isexistingatthemeasuringsite?Bymeansofaspecialdrillingdeviceameasuringsitewith1/2”ballvalvecanbeeasilysetupwithinafewminutesatanyplaceinthecompressedairsystem.

OD tUBe external threaD tUBe tOtal lenght OrDer nO.

20.0mm G1/4“ 20.0x7.0mm 180mm 40000006

21.3mm G1/2” 21.3x2.6mm 500mm 40000015

26.9mm G3/4” 26.9x2.6mm 600mm 40000020

33.7mm G1” 33.7x3.2mm 750mm 40000025

42.4mm G11/4” 42.4x3,.2mm 900mm 40000032

48.3mm G11/2” 48.3x3.2mm 1000mm 40000040

60.3mm G2” 60.3x3.6mm 1250mm 40000050

76.1mm G21/2” 76.1x3.6mm 1500mm 40000065

FlangeDIN2633

88.9mm DN80/88.9 88.9x2.0mm 1850mm 40000080

114.3mm DN100/114,3 114.3x2.0mm 2104mm 40000100

139.7mm DN125/139,7 139.7x3.0mm 2860mm 40000125

168.3mm DN150/168.3 168.3x3.0mm 3110mm 40000150

• Drillingunderpressure

DeScriptiOn OrDer nO.

Drillingjigincludingdrill 05301108

High-pressureprotection 05301105recommendedformeasurementsfrom10barupto50bar

Spotdrillingcollaroutertube 05000453diameter58-65mm,includingballvalve

Spotdrillingcollaroutertube 05000454diameter67-74mm,includingballvalve

Spotdrillingcollarsforother onrequestdiameters

• Measuringsection1/4”

• Measuringsection1/2”

• Drillingdevice

• High-pressureprotection

• Spotdrillingcollar