Page 1: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

cisco_ucs Guide v1.5 series

Nimsoft® Monitor™

Page 2: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Legal Notices Copyright © 2012, CA. All rights reserved.

Warranty

The material contained in this document is provided "as is," and is subject to being changed, without notice, in future editions. Further, to the maximum extent permitted by applicable law, Nimsoft LLC disclaims all warranties, either express or implied, with regard to this manual and any information contained herein, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. Nimsoft LLC shall not be liable for errors or for incidental or consequential damages in connection with the furnishing, use, or performance of this document or of any information contained herein. Should Nimsoft LLC and the user have a separate written agreement with warranty terms covering the material in this document that conflict with these terms, the warranty terms in the separate agreement shall control.

Technology Licenses

The hardware and/or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license.

No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or translation into a foreign language) without prior agreement and written consent from Nimsoft LLC as governed by United States and international copyright laws.

Restricted Rights Legend

If software is for use in the performance of a U.S. Government prime contract or subcontract, Software is delivered and licensed as "Commercial computer software" as defined in DFAR 252.227-7014 (June 1995), or as a "commercial item" as defined in FAR 2.101(a) or as "Restricted computer software" as defined in FAR 52.227-19 (June 1987) or any equivalent agency regulation or contract clause. Use, duplication or disclosure of Software is subject to Nimsoft LLC’s standard commercial license terms, and non-DOD Departments and Agencies of the U.S. Government will receive no greater than Restricted Rights as defined in FAR 52.227-19(c)(1-2) (June 1987). U.S. Government users will receive no greater than Limited Rights as defined in FAR 52.227-14 (June 1987) or DFAR 252.227-7015 (b)(2) (November 1995), as applicable in any technical data.

Trademarks

Nimsoft is a trademark of CA.

Adobe®, Acrobat®, Acrobat Reader®, and Acrobat Exchange® are registered trademarks of Adobe Systems Incorporated.

Intel® and Pentium® are U.S. registered trademarks of Intel Corporation.

Java(TM) is a U.S. trademark of Sun Microsystems, Inc.

Microsoft® and Windows® are U.S. registered trademarks of Microsoft Corporation.

Netscape(TM) is a U.S. trademark of Netscape Communications Corporation.

Oracle® is a U.S. registered trademark of Oracle Corporation, Redwood City, California.

UNIX® is a registered trademark of the Open Group.

ITIL® is a Registered Trade Mark of the Office of Government Commerce in the United Kingdom and other countries.

All other trademarks, trade names, service marks and logos referenced herein belong to their respective companies.

Page 3: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Contact Nimsoft

For your convenience, Nimsoft provides a single site where you can access information about Nimsoft products.

At http://support.nimsoft.com/, you can access the following:

■ Online and telephone contact information for technical assistance and customer services

■ Information about user communities and forums

■ Product and documentation downloads

■ Nimsoft Support policies and guidelines

■ Other helpful resources appropriate for your product

Provide Feedback

If you have comments or questions about Nimsoft product documentation, you can send a message to [email protected].

Page 4: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors
Page 5: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Contents 5

Contents

Chapter 1: cisco_ucs 1.5 7

cisco_ucs Overview ...................................................................................................................................................... 7

Requirements ............................................................................................................................................................... 8

Installation Notes ......................................................................................................................................................... 8

Chapter 2: cisco_ucs configuration 9

General tab ................................................................................................................................................................... 9

Advanced tab ............................................................................................................................................................. 10

Creating a New Group ................................................................................................................................................ 12

Creating a Host Profile ............................................................................................................................................... 13

Appendix A: Mapping the Fault Severity 17

Working with Monitors .............................................................................................................................................. 17

Editing Monitor Properties ................................................................................................................................. 18

Equipment .................................................................................................................................................................. 21

Chassis Interface Card ......................................................................................................................................... 21

Fabric Interconnects............................................................................................................................................ 23

Rack Mounts ....................................................................................................................................................... 24

Viewing History .......................................................................................................................................................... 25

Faults .......................................................................................................................................................................... 26

Pools ........................................................................................................................................................................... 27

UCS Service Profiles .................................................................................................................................................... 28

Importing the threshold policies into template ......................................................................................................... 30

Configuring Alarms and QoS ...................................................................................................................................... 31

Configuring a QoS................................................................................................................................................ 32

cisco_ucs QoS Metrics ......................................................................................................................................... 32

Using Templates ......................................................................................................................................................... 33

Adding monitors to a template ........................................................................................................................... 34

Wildcard or Fixed monitor templates ................................................................................................................ 35

AutoConfiguration ............................................................................................................................................... 36

Message Pool ............................................................................................................................................................. 39

Create new message ........................................................................................................................................... 40

Chapter 3: cisco_ucs Metrics 41

Page 6: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors
Page 7: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Chapter 1: cisco_ucs 1.5 7

Chapter 1: cisco_ucs 1.5

This description applies to cisco_ucs probe version 1.4.

This section contains the following topics:

cisco_ucs Overview (see page 7) Documentation Changes (see page 8) Requirements (see page 8) Installation Notes (see page 8)

cisco_ucs Overview

The Nimsoft cisco_ucs probe is a tool for managing the health and performance of your Unified Computing System (UCS).

The Cisco Unified Computing System is a next-generation data center platform that unites computing, networking, storage access, and virtualization into a cohesive system designed to reduce total cost of ownership (TCO) and increase business agility.

Page 8: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Requirements

8 cisco_ucs Guide

Documentation Changes

This table describes the version history for this document.

Version Date What's New?

1.5 September 2012

Added support for UCS Manager 2.0; Added Status and Count Indicators for monitors; added predefined QoS for several monitors.

1.4 September 2011

Updated the Advanced tab section and added theWorking with Monitors section.

1.3 June 2011 Added support for rack mounted units; added metrics for Interface Cards; and added support for multiple selection of thresholds.

Related Documentation

Documentation for other versions of the cisco_ucs probe

Getting Started with Nimsoft® Probes

Nimsoft® Probes Reference

Requirements

Platform: Windows, Linux, Solaris

Software: Cisco Unified Computing System Manager (Cisco UCSM) v1.3 and later

Installation Notes

The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors and VMs installed on the UCS blade servers.

This requires a secure communication set up between VMWare vCenter and Cisco UCS Manager (using the vCenter extension files).

Page 9: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Chapter 2: cisco_ucs configuration 9

Chapter 2: cisco_ucs configuration

The probe is configured by double-clicking the probe in the Infrastructure Manager, which brings up the GUI.

This section contains the following topics:

General tab (see page 9) Advanced tab (see page 10) Creating a New Group (see page 12) Creating a Host Profile (see page 13) Working with Monitors (see page 17) Equipment (see page 21) Viewing History (see page 25) Faults (see page 26) Pools (see page 27) UCS Service Profiles (see page 28) Importing the threshold policies into template (see page 30) Configuring Alarms and QoS (see page 31) Using Templates (see page 33) Message Pool (see page 39)

General tab

The General tab enables you to set the depth to which log details should be maintained. Move the slider to set the desired log level.

Page 10: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Advanced tab

10 cisco_ucs Guide

Advanced tab

The Advanced tab allows you to set advanced parameters for the probe. You can customize these values according to your monitoring requirements and the available system setup.

Page 11: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Advanced tab

Chapter 2: cisco_ucs configuration 11

The Advanced tab enables you to configure the following parameters:

Profile Check Interval

Click the time interval when the probe must poll the UCS for the profile information.

Max. number of threads

Move the slider to set the maximum number of profiles that the probe must monitor simultaneously.

UCSM XML API timeout

Enter the time duration when the probe must wait for a response from the UCS XML API.

UCSM ping timeout

Enter the time duration when the probe must wait for the UCS Manager to respond.

The probe starts a profile check with a ping to the UCS Manager. The probe does not check anything further if there is no response from the UCS Manager, or a timeout.

Note: You can disable the ping by setting this threshold to 0. The probe will query the UCS XML API and wait for a timeout there instead.

Logsize

Enter the size of the probe log file to which the probe must add internal log messages.

If the size of the log file reaches this value, the probe clears the contents of the log file.

Disable usage metering QoS

Select this check box to disable the probe from sending the usage metering QoS.

Page 12: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Creating a New Group

12 cisco_ucs Guide

Creating a New Group

By default, the probe contains a group, called the Default Group, for creating the host profiles. However, you can create more groups by clicking the Create a new group folder button.

The new group folder is added to the tree-view with a default name. You can edit the name, create sub-groups under a group, create a host profile under the group or delete the group by right-clicking on the New Group name and selecting the respective menu option in the context menu.

Page 13: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Creating a Host Profile

Chapter 2: cisco_ucs configuration 13

Creating a Host Profile

To create a host profile, click the Create new host profile button on the toolbar.

The Profile dialog opens.

Page 14: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Creating a Host Profile

14 cisco_ucs Guide

The fields are:

Hostname or IP address

Enter the machine name or IP address of the UCS Manager

Port

Enter the port number to connect to the UCS Manager. Usually, the port number is 443 or 80

Active

Select this checkbox to activate the profile

Group

Select the group under which the new profile is to be created

Alarm Message

Choose an alarm message from the drop-down. For more details about alarm messages, please refer to the Message Pool section.

Description

Enter a brief description for the profile.

Send UCS Faults as Nimsoft Alarms

Select this checkbox if you wish to convert the UCS Faults into Nimsoft Alarms

The severity of the Fault is converted to the corresponding Nimsoft Alarm severity. The severity "mapping" might be changed using raw-configure. For more details, see the Mapping the Fault Severity section.

User Name and Password

Provide a valid user name and password.

Important! If Cisco UCS has been set up for LDAP Authentication the login will require a domain name in addition to the user name. The convention for this username is: ucs-<domain-name>\<username>.

Example:

If the username is nimsoft and the domain is LOCAL, the username to enter for LDAP authentication is: ucs-LOCAL\nimsoft

Authentication Message

Select an alarm message from the drop-down

Alarm

Select a source for the alarm from the drop-down. Two options are available:

■ Host address: Choose this option to set the IP address of the agent profile as the source for the alarm

■ Profile name: Choose this option to set the name of the agent profile as the source for the alarm

Page 15: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Creating a Host Profile

Chapter 2: cisco_ucs configuration 15

QoS

Select a source for the QoS from the drop-down. Two options are available:

■ Host address: Choose this option to set the IP address of the agent profile as the source for the QoS

■ Profile name: Choose this option to set the name of the agent profile as the source for the QoS

After entering all the necessary details, click the Start Query button to generate the profile. The generated profile is displayed in the probe GUI.

Once the profile has been successfully created, you can drill down into the UCS and activate Alarms or QoS on the provided checkpoints.

The probe delivers QoS for state metrics as well. The states are translated into integer values based on the /Constants section in the probe .cfg file.

The probe can raise an alarm if a state is equal or not equal to the threshold.

Page 16: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors
Page 17: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Appendix A: Mapping the Fault Severity 17

Appendix A: Mapping the Fault Severity

Right-click on the cisco_ucs probe in the Infrastructure Manager while holding down the SHIFT key. Select Raw Configure option from the context menu.

From the tree-view in left frame, select FaultSeverity.

Select a Key value and click Edit Key to change the value.

Working with Monitors

The cisco_ucs probe retrieves the tree structure of the nodes, and the monitors within the nodes, from the UCS.

You can navigate through the tree structure of the nodes within the host profile, and select a node to view its monitors on the right pane.

Page 18: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Working with Monitors

18 cisco_ucs Guide

Editing Monitor Properties

You can edit monitor properties in one of the following ways:

■ Right click a monitor and select Edit.

■ Double click a monitor name.

The Monitor Properties window appears.

Page 19: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Working with Monitors

Appendix A: Mapping the Fault Severity 19

The fields are:

Name

The probe provides a default name for the monitor.

You can edit the name of the monitor.

Monitoring Object

The probe provides a short description of the object being monitored and its location from UCS.

You cannot edit the Monitoring Object or its location.

Description

Enter a description for the monitor.

Value definition

Click a predefined value that the probe must use to compare with the threshold value.

This option is inactive if the value is either a character or a string.

You can use one of the following options to define the value:

■ The current value – Click this option to use the current value measured.

■ The delta value – Click this option to use the delta value, which is current value – previous value.

■ Delta per second – Click this option to use the average of two values collected within a second, which is (current + previous)/2.

Note: When you set the value definition to The delta value or Delta per Second, the calculated value appears in the probe interface along with the actual value.

Page 20: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Working with Monitors

20 cisco_ucs Guide

Using Ratio

Select this check box and enter a scaling factor to display the value in the UMP graphs.

If the value is a character or a string, this check box appears dimmed.

Enable Monitoring

Select this check box to start using this monitor.

Click the appropriate mathematical operator, and specify the Threshold, Unit, and Message token.

Publish Quality of Service (QoS)

Select this check box to publish QoS messages.

In the drop down list box for QoS name, a default QoS will typically be chosen for you.

Page 21: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Equipment

Appendix A: Mapping the Fault Severity 21

If you see <Default> in the drop down list box it is recommended that you create your own QoS by selecting the down arrow and selecting <Add New QoS Definition>. The QoS Definition screen appears.

See the Configuring a QoS (see page 32) section for details.

Equipment

Chassis Interface Card

The server blade interface cards provide the traffic metric states.

Page 22: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Equipment

22 cisco_ucs Guide

If configured, the NICs on the server blade interface cards also provide traffic metrics (number of packets sent, packets dropped, errors, etc.).

The information of the disks attached to the server blades is available at Equipment > Chassis/Rack Mounts > Servers. The metrics collect the disk status values.

Page 23: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Equipment

Appendix A: Mapping the Fault Severity 23

Fabric Interconnects

The ports in the Fixed Module / Expansion Module(s) are grouped into the following categories, based on the "ifRole" property in the Cisco UCS Manager.

■ Appliance Ports

■ FCoE Storage Ports

■ Monitoring Ethernet Ports

■ Monitoring FC Ports

■ Server Ports

■ Unconfigured Ports

■ Uplink Ethernet Ports

■ Uplink FC Ports

The NIC nodes display an aggregated view of bandwidth (the bandwidth available for the Chassis, for Uplink to VSANs etc.).

Page 24: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Equipment

24 cisco_ucs Guide

Rack Mounts

Rack Mounts class is available in the Equipment node. The children nodes of this class are FEX and Servers. Rack Mounts have many similarities with the equipmentChassis class. The cisco_ucs probe should automatically detect if any RackUnits are managed by the UCS Manager.

Page 25: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Viewing History

Appendix A: Mapping the Fault Severity 25

Viewing History

The UCS provides a history buffer for counters.

Note: History does not apply to "states".

To view the history for items that support history, right click a counter from the grid, and from the context menu, select History option.

The following screenshot shows the history for the Speed of fan.

Page 26: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Faults

26 cisco_ucs Guide

Faults

The Faults item displays the various faults and the relevant details such as severity, fault code, ID, the affected object, cause for the faults, last transition date and time, and a brief description of the fault.

Page 27: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Pools

Appendix A: Mapping the Fault Severity 27

Pools

The Cisco UCS contains a number of ‘pools’ such as a MAC Pool (list of available MAC addresses), WWNN pool, WWPN pools, etc. It is useful for the system administrators to be aware of how many of these pools are empty, how many are assigned, and so on.

The cisco_ucs probe supports the following pools. They are displayed in the tree view of the probe GUI.

■ MAC Pools

■ Server Pools

■ UUID Pools

■ WWNN Pools

■ WWPN Pools

Page 28: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

UCS Service Profiles

28 cisco_ucs Guide

UCS Service Profiles

The service profiles created in the Cisco UCSM are displayed in the tree view of cisco_ucs probe GUI under the UCS Service Profiles node.

Page 29: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

UCS Service Profiles

Appendix A: Mapping the Fault Severity 29

Right-clicking a service profile from the tree view opens a context-menu.

■ Choose Refresh option to update the service profile with latest changes.

■ Choose Information to view additional details as provided by UCS.

Note: For any monitor, right-click and choose information to view additional details as provided by UCS.

Page 30: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Importing the threshold policies into template

30 cisco_ucs Guide

Importing the threshold policies into template

The threshold policies created in UCSM are displayed under the UCS Threshold Policies node in the treeview of cisco_ucs probe GUI.

You can import one or more existing threshold policies in to a template.

Right click one or more threshold policies and select "Add to template" context-menu. A dialog appears allowing you to select the template into which you wish to import the threshold policies.

Page 31: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Configuring Alarms and QoS

Appendix A: Mapping the Fault Severity 31

Select the required template from the drop-down and click OK.

The selected threshold policies are imported into the template.

It is a good idea to to add the templates based on thresholds-policies in autoconfiguration, so that after each interval the probe will try to detect if there are any classnames ( for example, processorErrorStats) available on any of the processors.

Configuring Alarms and QoS

To select the threshold values of a metric, Double-click the metric from the interface to open the Monitor Properties window.

Note: You can select multiple values to compare a Status value to in order to determine if a threshold has been exceeded.

Page 32: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Configuring Alarms and QoS

32 cisco_ucs Guide

Configuring a QoS

The QoS node displays the configured QoS for the system.

To create a QoS, right click on the QoS node and from the context menu, select New. The QoS Definition dialog appears.

Enter the required details such as the name for QoS, group, a brief description, QoS unit and its abbreviation. Also, select a flag to specify if the QoS is Boolean or has a maximum value.

Click OK. The new QoS is added to the tree view.

cisco_ucs QoS Metrics

Quality of Service (QoS) metrics for the cisco_ucs probe.

Name Units Description

QOS_UCS_CURRENT Ampere (A) Current

QOS_UCS_FAN_SPEED RPM Fan Speed

QOS_UCS_POWER Watt (W) Power

QOS_UCS_TEMPERATURE Celsius (C) Temperature

QOS_UCS_VOLTAGE Volt (V) Voltage

Page 33: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Using Templates

Appendix A: Mapping the Fault Severity 33

Using Templates

You can create templates for monitors using the Templates node. From the tree view, right-click on the Templates node and from the context menu, select New.

The Template Properties dialog appears. Enter a name for the template and brief description for it.

Click OK. The new template is added to the tree-view.

You can edit or delete a template by right clicking it in the tree view and choosing the appropriate option from the context menu.

To apply a template, you can simply drag and drop the template onto new profiles.

More Information

Adding monitors to a template Wildcard or Fixed monitor templates Auto Configuration

Page 34: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Using Templates

34 cisco_ucs Guide

Adding monitors to a template

To add monitors to templates, first configure a set of monitors on an existing profile.

Right-click one or more of the configured monitors and from the context menu, select Add to template.

The Select Template dialog appears. From the Name drop-down, select the template to which you wish to add the monitor(s). Click OK.

Note: Alternatively, you can also simply drag and drop the configured monitors onto a template item in the tree-view.

Page 35: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Using Templates

Appendix A: Mapping the Fault Severity 35

Wildcard or Fixed monitor templates

When you drag monitors on to a template, you can choose whether to create a wildcard template monitor or fixed template monitor.

If you create a wildcard, then on template deployment, monitors for all current instances of the specified class will be created.

A good place to start is to create a wildcard template for one of the fan-modules, and then deploy it to confirm whether monitors are created for all available fan-modules in every chassis.

After performing any of the above action, the selected monitors will be assigned to the selected template as shown in the figure below.

Page 36: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Using Templates

36 cisco_ucs Guide

AutoConfiguration

To create automonitors, drag and drop a metric (e.g. a fan-module metric) on to the AutoConfiguration node.

Apply and restart the probe. The icons indicate that monitors for all available metrics are created.

If a new fan-module has been added, the probe will pick it up and apply monitor. Furthermore, if a new chassis is inserted, the probe will automatically create monitors for the fan-modules inside that new chassis.

Page 37: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Using Templates

Appendix A: Mapping the Fault Severity 37

Static monitors and automonitors:

■ Static monitors override automonitors.

■ You can convert automonitor instances to static monitors if you want to treat a particular instance separately (e.g. set a different threshold or disable alarming). Then once you delete the static, automonitors will be created.

When you double-click an automonitor, the following message appears.

When you click Yes, the Monitor properties dialog appears.

Page 38: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Using Templates

38 cisco_ucs Guide

Configure the require settings as shown and click OK.

The selected automonitor now becomes a static monitor, as indicated by its icon.

Difference between wildcard templates and automonitors:

When wildcard templates are deployed, static monitors are created for the current available instances (So if you e.g. insert a new chassis, you will have to deploy the template once more in order for monitors to be created).

If you create automonitors, then the probe automatically detect new instances, and applies the configured automonitors.

Note: You may drag templates on to the AutoConfigurations node. If any fixed monitors are part of the template, then they are no longer fixed to that particular instance. This implies that from the AutoConfiguration point of view, it does not matter if you have a fixed or wildcard template monitor. All instances will automatically be monitored.

Page 39: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

Appendix A: Mapping the Fault Severity 39

Message Pool

You can create alarm messages by using the Message Pool dialog.

From the toolbar, click the Message Pool Manager button.

The Message Pool window appears, displaying the currently configured alarm messages.

More Information

Create new message

Page 40: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

40 cisco_ucs Guide

Create new message

To create a new alarm message, click the Add Message button from the Message Pool window.

Message Properties dialog appears.

Enter the necessary details such as identification name for the alarm message, message token, text for the alarm message, text to be displayed on clearing the alarm, severity (if applicable) and the subsystem string or ID.

Click OK to save the alarm message. The new alarm message is listed in the Message Pool.

Page 41: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Chapter 3: cisco_ucs Metrics 41

Chapter 3: cisco_ucs Metrics

The following table describes the checkpoint metrics that can be configured using the cisco_ucs probe.

Monitor Name Units Description

Application.Cisco_UCS

Status Indicates if the UCS Manager responds to ping.

Authentication Indicate if the cisco_ucs probe has the proper credentials (username/password) to communicate with the UCS Manager.

Fault UCS faults translated into Nimsoft Alarms.

Application.Cisco_UCS.Chassis

Administrative State Type: equipmentChassisAdminState

The potential values can be:

■ acknowledged = 1

■ re-acknowledge = 2

■ decommission = 3

■ remove = 4

Config State Type: equipmentChassisConfigState

The potential values can be:

■ uninitialized = 0

■ unacknowledged = 1

■ unsupported-connectivity = 2

■ ok = 3

■ removing = 4

Input Power Watt (W)

Page 42: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

42 cisco_ucs Guide

Monitor Name Units Description

Operability Type: equipmentOperability

The potential values can be:

■ unknown = 0

■ operable = 1

■ inoperable = 2

■ degraded = 3

■ powered-off = 4

■ power-problem = 5

■ removed = 6

■ voltage-problem = 7

■ thermal-problem = 8

■ performance-problem = 9

■ accessibility-problem = 10

■ identity-unestablishable = 11

■ bios-post-timeout = 12

■ disabled = 13

■ fabric-conn-problem = 51

■ fabric-unsupported-conn = 52

■ config = 81

■ equipment-problem = 82

■ decomissioning = 83

■ chassis-limit-exceeded = 84

■ not-supported = 100

■ discovery = 101

■ discovery-failed = 102

■ identify = 103

■ post-failure = 104

■ upgrade-problem = 105

■ peer-comm-problem = 106

■ auto-upgrade = 107

Output Power Watt (W)

Page 43: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

Chapter 3: cisco_ucs Metrics 43

Monitor Name Units Description

Overall Status Type: equipmentOperability

The potential values can be:

■ unknown = 0

■ operable = 1

■ inoperable = 2

■ degraded = 3

■ powered-off = 4

■ power-problem = 5

■ removed = 6

■ voltage-problem = 7

■ thermal-problem = 8

■ performance-problem = 9

■ accessibility-problem = 10

■ identity-unestablishable = 11

■ bios-post-timeout = 12

■ disabled = 13

■ fabric-conn-problem = 51

■ fabric-unsupported-conn = 52

■ config = 81

■ equipment-problem = 82

■ decomissioning = 83

■ chassis-limit-exceeded = 84

■ not-supported = 100

■ discovery = 101

■ discovery-failed = 102

■ identify = 103

■ post-failure = 104

■ upgrade-problem = 105

■ peer-comm-problem = 106

■ auto-upgrade = 107

Page 44: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

44 cisco_ucs Guide

Monitor Name Units Description

Power Type: equipmentChassisPowerOperState

The potential values can be:

■ unknown = 0

■ ok = 1

■ failed = 2

■ input-failed = 3

■ input-degraded = 4

■ output-failed = 5

■ output-degraded = 6

■ redundancy-failed = 7

■ redundancy-degraded = 8

Presence Type: equipmentPresence

Indicates whether the component exists in the system, regardless of its operational state.

The potential values can be:

■ unknown = 0

■ empty = 1

■ equipped = 10

■ missing = 11

■ mismatch = 12

■ equipped-not-primary = 13

■ equipped-identity-unestablishable = 20

■ mismatch-identity-unestablishable = 21

■ inaccessible = 30

■ unauthorized = 40

■ not-supported = 100

Page 45: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

Chapter 3: cisco_ucs Metrics 45

Monitor Name Units Description

Thermal Type: equipmentSensorThresholdStatus

The potential values can be:

■ unknown = 0

■ ok = 1

■ upper-non-recoverable = 2

■ upper-critical = 3

■ upper-non-critical = 4

■ lower-non-critical = 5

■ lower-critical = 6

■ lower-non-recoverable = 7

■ not-supported = 100

Application.Cisco_UCS.Chassis.FanModule

Page 46: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

46 cisco_ucs Guide

Monitor Name Units Description

Operability Type: equipmentOperability

The potential values can be:

■ unknown = 0

■ operable = 1

■ inoperable = 2

■ degraded = 3

■ powered-off = 4

■ power-problem = 5

■ removed = 6

■ voltage-problem = 7

■ thermal-problem = 8

■ performance-problem = 9

■ accessibility-problem = 10

■ identity-unestablishable = 11

■ bios-post-timeout = 12

■ disabled = 13

■ fabric-conn-problem = 51

■ fabric-unsupported-conn = 52

■ config = 81

■ equipment-problem = 82

■ decomissioning = 83

■ chassis-limit-exceeded = 84

■ not-supported = 100

■ discovery = 101

■ discovery-failed = 102

■ identify = 103

■ post-failure = 104

■ upgrade-problem = 105

■ peer-comm-problem = 106

■ auto-upgrade = 107

Page 47: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

Chapter 3: cisco_ucs Metrics 47

Monitor Name Units Description

Overall Status Type: equipmentOperability

The potential values can be:

■ unknown = 0

■ operable = 1

■ inoperable = 2

■ degraded = 3

■ powered-off = 4

■ power-problem = 5

■ removed = 6

■ voltage-problem = 7

■ thermal-problem = 8

■ performance-problem = 9

■ accessibility-problem = 10

■ identity-unestablishable = 11

■ bios-post-timeout = 12

■ disabled = 13

■ fabric-conn-problem = 51

■ fabric-unsupported-conn = 52

■ config = 81

■ equipment-problem = 82

■ decomissioning = 83

■ chassis-limit-exceeded = 84

■ not-supported = 100

■ discovery = 101

■ discovery-failed = 102

■ identify = 103

■ post-failure = 104

■ upgrade-problem = 105

■ peer-comm-problem = 106

■ auto-upgrade = 107

Page 48: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

48 cisco_ucs Guide

Monitor Name Units Description

Performance Type: equipmentSensorThresholdStatus

The potential values can be:

■ unknown = 0

■ ok = 1

■ upper-non-recoverable = 2

■ upper-critical = 3

■ upper-non-critical = 4

■ lower-non-critical = 5

■ lower-critical = 6

■ lower-non-recoverable = 7

■ not-supported = 100

Power Type: equipmentPowerState

The potential values can be:

■ unknown = 0

■ on = 1

■ test = 2

■ off = 3

■ online = 4

■ offline = 5

■ offduty = 6

■ degraded = 7

■ power-save = 8

■ error = 9

■ not-supported = 100

Page 49: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

Chapter 3: cisco_ucs Metrics 49

Monitor Name Units Description

Presence Type: equipmentPresence

Indicates whether the component exists in the system, regardless of its operational state.

The potential values can be:

■ unknown = 0

■ empty = 1

■ equipped = 10

■ missing = 11

■ mismatch = 12

■ equipped-not-primary = 13

■ equipped-identity-unestablishable = 20

■ mismatch-identity-unestablishable = 21

■ inaccessible = 30

■ unauthorized = 40

■ not-supported = 100

Thermal Type: equipmentSensorThresholdStatus

The potential values can be:

■ unknown = 0

■ ok = 1

■ upper-non-recoverable = 2

■ upper-critical = 3

■ upper-non-critical = 4

■ lower-non-critical = 5

■ lower-critical = 6

■ lower-non-recoverable = 7

■ not-supported = 100

Page 50: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

50 cisco_ucs Guide

Monitor Name Units Description

Voltage Type: equipmentSensorThresholdStatus

The potential values can be:

■ unknown = 0

■ ok = 1

■ upper-non-recoverable = 2

■ upper-critical = 3

■ upper-non-critical = 4

■ lower-non-critical = 5

■ lower-critical = 6

■ lower-non-recoverable = 7

■ not-supported = 100

Application.Cisco_UCS.Chassis.FanModule.Fan

Speed RPM The fan speed in revolutions per minute

Page 51: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

Chapter 3: cisco_ucs Metrics 51

Monitor Name Units Description

Operability Type: equipmentOperability

The potential values can be:

■ unknown = 0

■ operable = 1

■ inoperable = 2

■ degraded = 3

■ powered-off = 4

■ power-problem = 5

■ removed = 6

■ voltage-problem = 7

■ thermal-problem = 8

■ performance-problem = 9

■ accessibility-problem = 10

■ identity-unestablishable = 11

■ bios-post-timeout = 12

■ disabled = 13

■ fabric-conn-problem = 51

■ fabric-unsupported-conn = 52

■ config = 81

■ equipment-problem = 82

■ decomissioning = 83

■ chassis-limit-exceeded = 84

■ not-supported = 100

■ discovery = 101

■ discovery-failed = 102

■ identify = 103

■ post-failure = 104

■ upgrade-problem = 105

■ peer-comm-problem = 106

■ auto-upgrade = 107

Page 52: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

52 cisco_ucs Guide

Monitor Name Units Description

Overall Status Type: equipmentOperability

The potential values can be:

■ unknown = 0

■ operable = 1

■ inoperable = 2

■ degraded = 3

■ powered-off = 4

■ power-problem = 5

■ removed = 6

■ voltage-problem = 7

■ thermal-problem = 8

■ performance-problem = 9

■ accessibility-problem = 10

■ identity-unestablishable = 11

■ bios-post-timeout = 12

■ disabled = 13

■ fabric-conn-problem = 51

■ fabric-unsupported-conn = 52

■ config = 81

■ equipment-problem = 82

■ decomissioning = 83

■ chassis-limit-exceeded = 84

■ not-supported = 100

■ discovery = 101

■ discovery-failed = 102

■ identify = 103

■ post-failure = 104

■ upgrade-problem = 105

■ peer-comm-problem = 106

■ auto-upgrade = 107

Page 53: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

Chapter 3: cisco_ucs Metrics 53

Monitor Name Units Description

Performance Type: equipmentSensorThresholdStatus

The potential values can be:

■ unknown = 0

■ ok = 1

■ upper-non-recoverable = 2

■ upper-critical = 3

■ upper-non-critical = 4

■ lower-non-critical = 5

■ lower-critical = 6

■ lower-non-recoverable = 7

■ not-supported = 100

Power Type: equipmentPowerState

The potential values can be:

■ unknown = 0

■ on = 1

■ test = 2

■ off = 3

■ online = 4

■ offline = 5

■ offduty = 6

■ degraded = 7

■ power-save = 8

■ error = 9

■ not-supported = 100

Page 54: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

54 cisco_ucs Guide

Monitor Name Units Description

Presence Type: equipmentPresence

Indicates whether the component exists in the system, regardless of its operational state.

The potential values can be:

■ unknown = 0

■ empty = 1

■ equipped = 10

■ missing = 11

■ mismatch = 12

■ equipped-not-primary = 13

■ equipped-identity-unestablishable = 20

■ mismatch-identity-unestablishable = 21

■ inaccessible = 30

■ unauthorized = 40

■ not-supported = 100

Thermal Type: equipmentSensorThresholdStatus

The potential values can be:

■ unknown = 0

■ ok = 1

■ upper-non-recoverable = 2

■ upper-critical = 3

■ upper-non-critical = 4

■ lower-non-critical = 5

■ lower-critical = 6

■ lower-non-recoverable = 7

■ not-supported = 100

Page 55: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

Chapter 3: cisco_ucs Metrics 55

Monitor Name Units Description

Voltage Type: equipmentSensorThresholdStatus

The potential values can be:

■ unknown = 0

■ ok = 1

■ upper-non-recoverable = 2

■ upper-critical = 3

■ upper-non-critical = 4

■ lower-non-critical = 5

■ lower-critical = 6

■ lower-non-recoverable = 7

■ not-supported = 100

Application.Cisco_UCS.Chassis.PSU

Input 210v Volt (V) Type: counter

The actual 210V input voltage

Internal Temperature Celsius (C) Type: counter

The internal PSU temperature

Page 56: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

56 cisco_ucs Guide

Monitor Name Units Description

Operability Type: equipmentOperability

The potential values can be:

■ unknown = 0

■ operable = 1

■ inoperable = 2

■ degraded = 3

■ powered-off = 4

■ power-problem = 5

■ removed = 6

■ voltage-problem = 7

■ thermal-problem = 8

■ performance-problem = 9

■ accessibility-problem = 10

■ identity-unestablishable = 11

■ bios-post-timeout = 12

■ disabled = 13

■ fabric-conn-problem = 51

■ fabric-unsupported-conn = 52

■ config = 81

■ equipment-problem = 82

■ decomissioning = 83

■ chassis-limit-exceeded = 84

■ not-supported = 100

■ discovery = 101

■ discovery-failed = 102

■ identify = 103

■ post-failure = 104

■ upgrade-problem = 105

■ peer-comm-problem = 106

■ auto-upgrade = 107

Output 12v Volt (V) Type: counter

The actual 12V output voltage

Page 57: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

Chapter 3: cisco_ucs Metrics 57

Monitor Name Units Description

Output 3v3 Volt (V) Type: counter

The actual 3.3V output voltage

Output Current Amperes (A) Type: counter

The output current

Output Power Watts (W) Type: counter

The output power

Page 58: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

58 cisco_ucs Guide

Monitor Name Units Description

Overall Status Type: equipmentOperability

The potential values can be:

■ unknown = 0

■ operable = 1

■ inoperable = 2

■ degraded = 3

■ powered-off = 4

■ power-problem = 5

■ removed = 6

■ voltage-problem = 7

■ thermal-problem = 8

■ performance-problem = 9

■ accessibility-problem = 10

■ identity-unestablishable = 11

■ bios-post-timeout = 12

■ disabled = 13

■ fabric-conn-problem = 51

■ fabric-unsupported-conn = 52

■ config = 81

■ equipment-problem = 82

■ decomissioning = 83

■ chassis-limit-exceeded = 84

■ not-supported = 100

■ discovery = 101

■ discovery-failed = 102

■ identify = 103

■ post-failure = 104

■ upgrade-problem = 105

■ peer-comm-problem = 106

■ auto-upgrade = 107

Page 59: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

Chapter 3: cisco_ucs Metrics 59

Monitor Name Units Description

Performance Type: equipmentSensorThresholdStatus

The potential values can be:

■ unknown = 0

■ ok = 1

■ upper-non-recoverable = 2

■ upper-critical = 3

■ upper-non-critical = 4

■ lower-non-critical = 5

■ lower-critical = 6

■ lower-non-recoverable = 7

■ not-supported = 100

Power Type: equipmentPowerState

The potential values can be:

■ unknown = 0

■ on = 1

■ test = 2

■ off = 3

■ online = 4

■ offline = 5

■ offduty = 6

■ degraded = 7

■ power-save = 8

■ error = 9

■ not-supported = 100

Page 60: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

60 cisco_ucs Guide

Monitor Name Units Description

Presence Type: equipmentPresence

Indicates whether the component exists in the system, regardless of its operational state.

The potential values can be:

■ unknown = 0

■ empty = 1

■ equipped = 10

■ missing = 11

■ mismatch = 12

■ equipped-not-primary = 13

■ equipped-identity-unestablishable = 20

■ mismatch-identity-unestablishable = 21

■ inaccessible = 30

■ unauthorized = 40

■ not-supported = 100

Thermal Type: equipmentSensorThresholdStatus

The potential values can be:

■ unknown = 0

■ ok = 1

■ upper-non-recoverable = 2

■ upper-critical = 3

■ upper-non-critical = 4

■ lower-non-critical = 5

■ lower-critical = 6

■ lower-non-recoverable = 7

■ not-supported = 100

Page 61: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

Chapter 3: cisco_ucs Metrics 61

Monitor Name Units Description

Voltage Type: equipmentSensorThresholdStatus

The potential values can be:

■ unknown = 0

■ ok = 1

■ upper-non-recoverable = 2

■ upper-critical = 3

■ upper-non-critical = 4

■ lower-non-critical = 5

■ lower-critical = 6

■ lower-non-recoverable = 7

■ not-supported = 100

Application.Cisco_UCS.Chassis.IOModule

Ambient Temperature Celsius (C) Type: counter

The surrounding temperature

ASIC Temperature Celsius (C) The temperature on the ASIC (Application Specific Integrated Circuit).

Page 62: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

62 cisco_ucs Guide

Monitor Name Units Description

Overall Status Type: equipmentOperability

The potential values can be:

■ unknown = 0

■ operable = 1

■ inoperable = 2

■ degraded = 3

■ powered-off = 4

■ power-problem = 5

■ removed = 6

■ voltage-problem = 7

■ thermal-problem = 8

■ performance-problem = 9

■ accessibility-problem = 10

■ identity-unestablishable = 11

■ bios-post-timeout = 12

■ disabled = 13

■ fabric-conn-problem = 51

■ fabric-unsupported-conn = 52

■ config = 81

■ equipment-problem = 82

■ decomissioning = 83

■ chassis-limit-exceeded = 84

■ not-supported = 100

■ discovery = 101

■ discovery-failed = 102

■ identify = 103

■ post-failure = 104

■ upgrade-problem = 105

■ peer-comm-problem = 106

■ auto-upgrade = 107

Page 63: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

Chapter 3: cisco_ucs Metrics 63

Monitor Name Units Description

Operability Type: equipmentOperability

The potential values can be:

■ unknown = 0

■ operable = 1

■ inoperable = 2

■ degraded = 3

■ powered-off = 4

■ power-problem = 5

■ removed = 6

■ voltage-problem = 7

■ thermal-problem = 8

■ performance-problem = 9

■ accessibility-problem = 10

■ identity-unestablishable = 11

■ bios-post-timeout = 12

■ disabled = 13

■ fabric-conn-problem = 51

■ fabric-unsupported-conn = 52

■ config = 81

■ equipment-problem = 82

■ decomissioning = 83

■ chassis-limit-exceeded = 84

■ not-supported = 100

■ discovery = 101

■ discovery-failed = 102

■ identify = 103

■ post-failure = 104

■ upgrade-problem = 105

■ peer-comm-problem = 106

■ auto-upgrade = 107

Application.Cisco_UCS.Chassis.IOModule.BackplanePort

Page 64: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

64 cisco_ucs Guide

Monitor Name Units Description

Administrative State Type: fabricAdminState

The potential values can be:

■ enabled = 0

■ disabled = 1

Overall Status Type: networkPortOperState

The potential values can be:

■ indeterminate = 0

■ up = 1

■ admin-down = 2

■ link-down = 3

■ failed = 4

■ no-license = 5

■ link-up = 6

■ hardware-failure = 7

■ software-failure = 8

■ error-disabled = 9

■ sfp-not-present = 10

Application.Cisco_UCS.Chassis.IOModule.FabricPort

Acknowledged Type: equipmentChassisConfigState

The potential values can be:

■ un-initialized = 0

■ un-acknowledged = 1

■ unsupported-connectivity = 2

■ ok = 3

■ removing = 4

Administrative State Type: fabricAdminState

The potential values can be:

■ enabled = 0

■ disabled = 1

Page 65: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

Chapter 3: cisco_ucs Metrics 65

Monitor Name Units Description

Discovery Type: etherSatelliteConnectionDisc

The potential values can be:

■ absent = 0

■ present = 1

■ mis-connect = 2

Overall Status Type: networkPortOperState

The potential values can be:

■ indeterminate = 0

■ up = 1

■ admin-down = 2

■ link-down = 3

■ failed = 4

■ no-license = 5

■ link-up = 6

■ hardware-failure = 7

■ software-failure = 8

■ error-disabled = 9

■ sfp-not-present = 10

Application.Cisco_UCS.Chassis.BladeServer

Administrative State Type: computeAdminState

The potential values can be:

■ in-service = 1

■ out-of-service = 2

Availability Type: computeAvailability

The potential values can be:

■ unavailable = 0

■ available = 1

Consumed Power Watt (W) Type: counter

Front Temperature Celsius (C) Type: counter

Input Current Ampere (A) Type: counter

Input Voltage Voltage (V) Type: counter

Page 66: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

66 cisco_ucs Guide

Monitor Name Units Description

Operability Type: equipmentOperability

The potential values can be:

■ unknown = 0

■ operable = 1

■ inoperable = 2

■ degraded = 3

■ powered-off = 4

■ power-problem = 5

■ removed = 6

■ voltage-problem = 7

■ thermal-problem = 8

■ performance-problem = 9

■ accessibility-problem = 10

■ identity-unestablishable = 11

■ bios-post-timeout = 12

■ disabled = 13

■ fabric-conn-problem = 51

■ fabric-unsupported-conn = 52

■ config = 81

■ equipment-problem = 82

■ decomissioning = 83

■ chassis-limit-exceeded = 84

■ not-supported = 100

■ discovery = 101

■ discovery-failed = 102

■ identify = 103

■ post-failure = 104

■ upgrade-problem = 105

■ peer-comm-problem = 106

■ auto-upgrade = 107

Page 67: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

Chapter 3: cisco_ucs Metrics 67

Monitor Name Units Description

Overall Status Type: IsOperState

The potential values can be:

■ indeterminate = 0

■ unassociated = 1

■ ok = 10

■ discovery = 11

■ config = 12

■ unconfig = 13

■ power-off = 14

■ restart = 15

■ maintenance = 20

■ test = 21

■ compute-mismatch = 29

■ compute-failed = 30

■ degraded = 31

■ discovery-failed = 32

■ config-failure = 33

■ unconfig-failed = 34

■ test-failed = 35

■ maintenance-failed = 36

■ removed = 40

■ disabled = 41

■ inaccessible = 50

■ thermal-problem = 60

■ power-problem = 61

■ voltage-problem = 62

■ inoperable = 63

■ decommissioning = 101

■ bios-restore = 201

■ cmos-reset = 202

■ diagnostics = 203

■ diagnostics-failed = 204

Page 68: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

68 cisco_ucs Guide

Monitor Name Units Description

Power Type: equipmentPowerState

The potential values can be:

■ unknown = 0

■ on = 1

■ test = 2

■ off = 3

■ online = 4

■ offline = 5

■ offduty = 6

■ degraded = 7

■ power-save = 8

■ error = 9

■ not-supported = 100

Presence Type: equipmentPresence

Indicates whether the component exists in the system, regardless of its operational state.

The potential values can be:

■ unknown = 0

■ empty = 1

■ equipped = 10

■ missing = 11

■ mismatch = 12

■ equipped-not-primary = 13

■ equipped-identity-unestablishable = 20

■ mismatch-identity-unestablishable = 21

■ inaccessible = 30

■ unauthorized = 40

■ not-supported = 100

Rear Temperature Celsius (C) Type: counter

Application.Cisco_UCS.Chassis.BladeServer.AdaptorUnit

NA NA NA

Application.Cisco_UCS.Chassis.BladeServer.AdaptorUnit.DCE

Page 69: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

Chapter 3: cisco_ucs Metrics 69

Monitor Name Units Description

Administrative State Type: scalarEnum8

The potential values can be:

■ enabled = 0

■ reset-connectivity-active = 44

■ reset-connectivity-passive = 45

■ reset-connectivity = 46

Overall Status Type: networkPortOperState

The potential values can be:

■ indeterminate = 0

■ up = 1

■ admin-down = 2

■ link-down = 3

■ failed = 4

■ no-license = 5

■ link-up = 6

■ hardware-failure = 7

■ software-failure = 8

■ error-disabled = 9

■ sfp-not-present = 10

Application.Cisco_UCS.Chassis.BladeServer.AdaptorUnit.HBA

Administrative State Type: scalarEnum8

The potential values can be:

■ enabled = 0

■ reset-connectivity-active = 44

■ reset-connectivity-passive = 45

■ reset-connectivity = 46

Page 70: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

70 cisco_ucs Guide

Monitor Name Units Description

Operability Type: equipmentOperability

The potential values can be:

■ unknown = 0

■ operable = 1

■ inoperable = 2

■ degraded = 3

■ powered-off = 4

■ power-problem = 5

■ removed = 6

■ voltage-problem = 7

■ thermal-problem = 8

■ performance-problem = 9

■ accessibility-problem = 10

■ identity-unestablishable = 11

■ bios-post-timeout = 12

■ disabled = 13

■ fabric-conn-problem = 51

■ fabric-unsupported-conn = 52

■ config = 81

■ equipment-problem = 82

■ decomissioning = 83

■ chassis-limit-exceeded = 84

■ not-supported = 100

■ discovery = 101

■ discovery-failed = 102

■ identify = 103

■ post-failure = 104

■ upgrade-problem = 105

■ peer-comm-problem = 106

■ auto-upgrade = 107

Page 71: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

Chapter 3: cisco_ucs Metrics 71

Monitor Name Units Description

Overall Status Type: equipmentOperability

The potential values can be:

■ unknown = 0

■ operable = 1

■ inoperable = 2

■ degraded = 3

■ powered-off = 4

■ power-problem = 5

■ removed = 6

■ voltage-problem = 7

■ thermal-problem = 8

■ performance-problem = 9

■ accessibility-problem = 10

■ identity-unestablishable = 11

■ bios-post-timeout = 12

■ disabled = 13

■ fabric-conn-problem = 51

■ fabric-unsupported-conn = 52

■ config = 81

■ equipment-problem = 82

■ decomissioning = 83

■ chassis-limit-exceeded = 84

■ not-supported = 100

■ discovery = 101

■ discovery-failed = 102

■ identify = 103

■ post-failure = 104

■ upgrade-problem = 105

■ peer-comm-problem = 106

■ auto-upgrade = 107

Page 72: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

72 cisco_ucs Guide

Monitor Name Units Description

Performance Type: equipmentSensorThresholdStatus

The potential values can be:

■ unknown = 0

■ ok = 1

■ upper-non-recoverable = 2

■ upper-critical = 3

■ upper-non-critical = 4

■ lower-non-critical = 5

■ lower-critical = 6

■ lower-non-recoverable = 7

■ not-supported = 100

Power Type: equipmentPowerState

The potential values can be:

■ unknown = 0

■ on = 1

■ test = 2

■ off = 3

■ online = 4

■ offline = 5

■ offduty = 6

■ degraded = 7

■ power-save = 8

■ error = 9

■ not-supported = 100

Page 73: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

Chapter 3: cisco_ucs Metrics 73

Monitor Name Units Description

Presence Type: equipmentPresence

Indicates whether the component exists in the system, regardless of its operational state.

The potential values can be:

■ unknown = 0

■ empty = 1

■ equipped = 10

■ missing = 11

■ mismatch = 12

■ equipped-not-primary = 13

■ equipped-identity-unestablishable = 20

■ mismatch-identity-unestablishable = 21

■ inaccessible = 30

■ unauthorized = 40

■ not-supported = 100

Thermal Type: equipmentSensorThresholdStatus

The potential values can be:

■ unknown = 0

■ ok = 1

■ upper-non-recoverable = 2

■ upper-critical = 3

■ upper-non-critical = 4

■ lower-non-critical = 5

■ lower-critical = 6

■ lower-non-recoverable = 7

■ not-supported = 100

Page 74: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

74 cisco_ucs Guide

Monitor Name Units Description

Voltage Type: equipmentSensorThresholdStatus

The potential values can be:

■ unknown = 0

■ ok = 1

■ upper-non-recoverable = 2

■ upper-critical = 3

■ upper-non-critical = 4

■ lower-non-critical = 5

■ lower-critical = 6

■ lower-non-recoverable = 7

■ not-supported = 100

Application.Cisco_UCS.Chassis.BladeServer.AdaptorUnit.NIC

Administrative State Type: scalarEnum8

The potential values can be:

■ enabled = 0

■ reset-connectivity-active = 44

■ reset-connectivity-passive = 45

■ reset-connectivity = 46

Page 75: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

Chapter 3: cisco_ucs Metrics 75

Monitor Name Units Description

Operability Type: equipmentOperability

The potential values can be:

■ unknown = 0

■ operable = 1

■ inoperable = 2

■ degraded = 3

■ powered-off = 4

■ power-problem = 5

■ removed = 6

■ voltage-problem = 7

■ thermal-problem = 8

■ performance-problem = 9

■ accessibility-problem = 10

■ identity-unestablishable = 11

■ bios-post-timeout = 12

■ disabled = 13

■ fabric-conn-problem = 51

■ fabric-unsupported-conn = 52

■ config = 81

■ equipment-problem = 82

■ decomissioning = 83

■ chassis-limit-exceeded = 84

■ not-supported = 100

■ discovery = 101

■ discovery-failed = 102

■ identify = 103

■ post-failure = 104

■ upgrade-problem = 105

■ peer-comm-problem = 106

■ auto-upgrade = 107

Page 76: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

76 cisco_ucs Guide

Monitor Name Units Description

Overall Status Type: equipmentOperability

The potential values can be:

■ unknown = 0

■ operable = 1

■ inoperable = 2

■ degraded = 3

■ powered-off = 4

■ power-problem = 5

■ removed = 6

■ voltage-problem = 7

■ thermal-problem = 8

■ performance-problem = 9

■ accessibility-problem = 10

■ identity-unestablishable = 11

■ bios-post-timeout = 12

■ disabled = 13

■ fabric-conn-problem = 51

■ fabric-unsupported-conn = 52

■ config = 81

■ equipment-problem = 82

■ decomissioning = 83

■ chassis-limit-exceeded = 84

■ not-supported = 100

■ discovery = 101

■ discovery-failed = 102

■ identify = 103

■ post-failure = 104

■ upgrade-problem = 105

■ peer-comm-problem = 106

■ auto-upgrade = 107

Page 77: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

Chapter 3: cisco_ucs Metrics 77

Monitor Name Units Description

Performance Type: equipmentSensorThresholdStatus

The potential values can be:

■ unknown = 0

■ ok = 1

■ upper-non-recoverable = 2

■ upper-critical = 3

■ upper-non-critical = 4

■ lower-non-critical = 5

■ lower-critical = 6

■ lower-non-recoverable = 7

■ not-supported = 100

Power Type: equipmentPowerState

The potential values can be:

■ unknown = 0

■ on = 1

■ test = 2

■ off = 3

■ online = 4

■ offline = 5

■ offduty = 6

■ degraded = 7

■ power-save = 8

■ error = 9

■ not-supported = 100

Page 78: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

78 cisco_ucs Guide

Monitor Name Units Description

Presence Type: equipmentPresence

Indicates whether the component exists in the system, regardless of its operational state.

The potential values can be:

■ unknown = 0

■ empty = 1

■ equipped = 10

■ missing = 11

■ mismatch = 12

■ equipped-not-primary = 13

■ equipped-identity-unestablishable = 20

■ mismatch-identity-unestablishable = 21

■ inaccessible = 30

■ unauthorized = 40

■ not-supported = 100

Thermal Type: equipmentSensorThresholdStatus

The potential values can be:

■ unknown = 0

■ ok = 1

■ upper-non-recoverable = 2

■ upper-critical = 3

■ upper-non-critical = 4

■ lower-non-critical = 5

■ lower-critical = 6

■ lower-non-recoverable = 7

■ not-supported = 100

Page 79: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

Chapter 3: cisco_ucs Metrics 79

Monitor Name Units Description

Voltage Type: equipmentSensorThresholdStatus

The potential values can be:

■ unknown = 0

■ ok = 1

■ upper-non-recoverable = 2

■ upper-critical = 3

■ upper-non-critical = 4

■ lower-non-critical = 5

■ lower-critical = 6

■ lower-non-recoverable = 7

■ not-supported = 100

Application.Cisco_UCS.Chassis.BladeServer.MemArray

Current Capacity MB Type: counter

Max Capacity MB

Application.Cisco_UCS.Chassis.BladeServer.MemArray.Memory

Temperature Celsius (C) Type: counter

Application.Cisco_UCS.Chassis.BladeServer.Processor

CPU Temperature Celsius (C) Type: counter

Input Current Ampere (A)

Application.Cisco_UCS.FabricInterconnect

Available Memory MB

Cached Memory MB

fanCtrlrlnlet1 Celsius (C)

fanCtrlrlnlet2 Celsius (C)

fanCtrlrlnlet3 Celsius (C)

fanCtrlrlnlet4 Celsius (C)

Load Percent (%) CPU Utilization: Load (%) of last 1 minute

mainBoardOutlet1 Celsius (C)

mainBoardOutlet2 Celsius (C)

Page 80: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

80 cisco_ucs Guide

Monitor Name Units Description

Operability Type: equipmentOperability

The potential values can be:

■ unknown = 0

■ operable = 1

■ inoperable = 2

■ degraded = 3

■ powered-off = 4

■ power-problem = 5

■ removed = 6

■ voltage-problem = 7

■ thermal-problem = 8

■ performance-problem = 9

■ accessibility-problem = 10

■ identity-unestablishable = 11

■ bios-post-timeout = 12

■ disabled = 13

■ fabric-conn-problem = 51

■ fabric-unsupported-conn = 52

■ config = 81

■ equipment-problem = 82

■ decomissioning = 83

■ chassis-limit-exceeded = 84

■ not-supported = 100

■ discovery = 101

■ discovery-failed = 102

■ identify = 103

■ post-failure = 104

■ upgrade-problem = 105

■ peer-comm-problem = 106

■ auto-upgrade = 107

psuCtrlrlnlet1 Celsius (C)

psuCtrlrlnlet2 Celsius (C)

Page 81: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

Chapter 3: cisco_ucs Metrics 81

Monitor Name Units Description

Application.Cisco_UCS.FabricInterconnect.Fan

Operability Type: equipmentOperability

The potential values can be:

■ unknown = 0

■ operable = 1

■ inoperable = 2

■ degraded = 3

■ powered-off = 4

■ power-problem = 5

■ removed = 6

■ voltage-problem = 7

■ thermal-problem = 8

■ performance-problem = 9

■ accessibility-problem = 10

■ identity-unestablishable = 11

■ bios-post-timeout = 12

■ disabled = 13

■ fabric-conn-problem = 51

■ fabric-unsupported-conn = 52

■ config = 81

■ equipment-problem = 82

■ decomissioning = 83

■ chassis-limit-exceeded = 84

■ not-supported = 100

■ discovery = 101

■ discovery-failed = 102

■ identify = 103

■ post-failure = 104

■ upgrade-problem = 105

■ peer-comm-problem = 106

■ auto-upgrade = 107

Page 82: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

82 cisco_ucs Guide

Monitor Name Units Description

Overall Status Type: equipmentOperability

The potential values can be:

■ unknown = 0

■ operable = 1

■ inoperable = 2

■ degraded = 3

■ powered-off = 4

■ power-problem = 5

■ removed = 6

■ voltage-problem = 7

■ thermal-problem = 8

■ performance-problem = 9

■ accessibility-problem = 10

■ identity-unestablishable = 11

■ bios-post-timeout = 12

■ disabled = 13

■ fabric-conn-problem = 51

■ fabric-unsupported-conn = 52

■ config = 81

■ equipment-problem = 82

■ decomissioning = 83

■ chassis-limit-exceeded = 84

■ not-supported = 100

■ discovery = 101

■ discovery-failed = 102

■ identify = 103

■ post-failure = 104

■ upgrade-problem = 105

■ peer-comm-problem = 106

■ auto-upgrade = 107

Page 83: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

Chapter 3: cisco_ucs Metrics 83

Monitor Name Units Description

Performance Type: equipmentSensorThresholdStatus

The potential values can be:

■ unknown = 0

■ ok = 1

■ upper-non-recoverable = 2

■ upper-critical = 3

■ upper-non-critical = 4

■ lower-non-critical = 5

■ lower-critical = 6

■ lower-non-recoverable = 7

■ not-supported = 100

Power Type: equipmentPowerState

The potential values can be:

■ unknown = 0

■ on = 1

■ test = 2

■ off = 3

■ online = 4

■ offline = 5

■ offduty = 6

■ degraded = 7

■ power-save = 8

■ error = 9

■ not-supported = 100

Page 84: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

84 cisco_ucs Guide

Monitor Name Units Description

Presence Type: equipmentPresence

Indicates whether the component exists in the system, regardless of its operational state.

The potential values can be:

■ unknown = 0

■ empty = 1

■ equipped = 10

■ missing = 11

■ mismatch = 12

■ equipped-not-primary = 13

■ equipped-identity-unestablishable = 20

■ mismatch-identity-unestablishable = 21

■ inaccessible = 30

■ unauthorized = 40

■ not-supported = 100

Thermal Type: equipmentSensorThresholdStatus

The potential values can be:

■ unknown = 0

■ ok = 1

■ upper-non-recoverable = 2

■ upper-critical = 3

■ upper-non-critical = 4

■ lower-non-critical = 5

■ lower-critical = 6

■ lower-non-recoverable = 7

■ not-supported = 100

Page 85: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

Chapter 3: cisco_ucs Metrics 85

Monitor Name Units Description

Voltage Type: equipmentSensorThresholdStatus

The potential values can be:

■ unknown = 0

■ ok = 1

■ upper-non-recoverable = 2

■ upper-critical = 3

■ upper-non-critical = 4

■ lower-non-critical = 5

■ lower-critical = 6

■ lower-non-recoverable = 7

■ not-supported = 100

Application.Cisco_UCS.FabricInterconnect.PSU

Page 86: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

86 cisco_ucs Guide

Monitor Name Units Description

Operability Type: equipmentOperability

The potential values can be:

■ unknown = 0

■ operable = 1

■ inoperable = 2

■ degraded = 3

■ powered-off = 4

■ power-problem = 5

■ removed = 6

■ voltage-problem = 7

■ thermal-problem = 8

■ performance-problem = 9

■ accessibility-problem = 10

■ identity-unestablishable = 11

■ bios-post-timeout = 12

■ disabled = 13

■ fabric-conn-problem = 51

■ fabric-unsupported-conn = 52

■ config = 81

■ equipment-problem = 82

■ decomissioning = 83

■ chassis-limit-exceeded = 84

■ not-supported = 100

■ discovery = 101

■ discovery-failed = 102

■ identify = 103

■ post-failure = 104

■ upgrade-problem = 105

■ peer-comm-problem = 106

■ auto-upgrade = 107

Page 87: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

Chapter 3: cisco_ucs Metrics 87

Monitor Name Units Description

Overall Status Type: equipmentOperability

The potential values can be:

■ unknown = 0

■ operable = 1

■ inoperable = 2

■ degraded = 3

■ powered-off = 4

■ power-problem = 5

■ removed = 6

■ voltage-problem = 7

■ thermal-problem = 8

■ performance-problem = 9

■ accessibility-problem = 10

■ identity-unestablishable = 11

■ bios-post-timeout = 12

■ disabled = 13

■ fabric-conn-problem = 51

■ fabric-unsupported-conn = 52

■ config = 81

■ equipment-problem = 82

■ decomissioning = 83

■ chassis-limit-exceeded = 84

■ not-supported = 100

■ discovery = 101

■ discovery-failed = 102

■ identify = 103

■ post-failure = 104

■ upgrade-problem = 105

■ peer-comm-problem = 106

■ auto-upgrade = 107

Page 88: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

88 cisco_ucs Guide

Monitor Name Units Description

Performance Type: equipmentSensorThresholdStatus

The potential values can be:

■ unknown = 0

■ ok = 1

■ upper-non-recoverable = 2

■ upper-critical = 3

■ upper-non-critical = 4

■ lower-non-critical = 5

■ lower-critical = 6

■ lower-non-recoverable = 7

■ not-supported = 100

Power Type: equipmentPowerState

The potential values can be:

■ unknown = 0

■ on = 1

■ test = 2

■ off = 3

■ online = 4

■ offline = 5

■ offduty = 6

■ degraded = 7

■ power-save = 8

■ error = 9

■ not-supported = 100

Page 89: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

Chapter 3: cisco_ucs Metrics 89

Monitor Name Units Description

Presence Type: equipmentPresence

Indicates whether the component exists in the system, regardless of its operational state.

The potential values can be:

■ unknown = 0

■ empty = 1

■ equipped = 10

■ missing = 11

■ mismatch = 12

■ equipped-not-primary = 13

■ equipped-identity-unestablishable = 20

■ mismatch-identity-unestablishable = 21

■ inaccessible = 30

■ unauthorized = 40

■ not-supported = 100

Thermal Type: equipmentSensorThresholdStatus

The potential values can be:

■ unknown = 0

■ ok = 1

■ upper-non-recoverable = 2

■ upper-critical = 3

■ upper-non-critical = 4

■ lower-non-critical = 5

■ lower-critical = 6

■ lower-non-recoverable = 7

■ not-supported = 100

Page 90: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

90 cisco_ucs Guide

Monitor Name Units Description

Voltage Type: equipmentSensorThresholdStatus

The potential values can be:

■ unknown = 0

■ ok = 1

■ upper-non-recoverable = 2

■ upper-critical = 3

■ upper-non-critical = 4

■ lower-non-critical = 5

■ lower-critical = 6

■ lower-non-recoverable = 7

■ not-supported = 100

Input Current Ampere (A)

Input Power Watt (W)

Input Voltage Volt (V)

Application.Cisco_UCS.FabricInterconnect.IOModule

Page 91: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

Chapter 3: cisco_ucs Metrics 91

Monitor Name Units Description

Operability Type: equipmentOperability

The potential values can be:

■ unknown = 0

■ operable = 1

■ inoperable = 2

■ degraded = 3

■ powered-off = 4

■ power-problem = 5

■ removed = 6

■ voltage-problem = 7

■ thermal-problem = 8

■ performance-problem = 9

■ accessibility-problem = 10

■ identity-unestablishable = 11

■ bios-post-timeout = 12

■ disabled = 13

■ fabric-conn-problem = 51

■ fabric-unsupported-conn = 52

■ config = 81

■ equipment-problem = 82

■ decomissioning = 83

■ chassis-limit-exceeded = 84

■ not-supported = 100

■ discovery = 101

■ discovery-failed = 102

■ identify = 103

■ post-failure = 104

■ upgrade-problem = 105

■ peer-comm-problem = 106

■ auto-upgrade = 107

Page 92: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

92 cisco_ucs Guide

Monitor Name Units Description

State Type: equipmentPowerState

The potential values can be:

■ unknown = 0

■ on = 1

■ test = 2

■ off = 3

■ online = 4

■ offline = 5

■ offduty = 6

■ degraded = 7

■ power-save = 8

■ error = 9

■ not-supported = 100

Application.Cisco_UCS.FabricInterconnect.IOModule.EtherPort

Administrative State Type: fabricAdminState

The potential values can be:

■ enabled = 0

■ disabled = 1

Align errors

BroadcastPackets(Rx) packets

BroadcastPackets(Tx) packets

Carrier Sense errors

Deferred Tx errors

Excess Collision errors

Fcs errors

Giants errors

Int Mac Rx errors

Int Mac Tx errors

Jumbo Packets (Rx) packets

Jumbo Packets (Tx) packets

Late Collision errors

Page 93: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

Chapter 3: cisco_ucs Metrics 93

Monitor Name Units Description

Multi Collision errors

Multicast Packets(Rx) packets

Multicast Packets(Tx) packets

Out Discard errors

Overall Status Type: networkPortOperState

The potential values can be:

■ indeterminate = 0

■ up = 1

■ admin-down = 2

■ link-down = 3

■ failed = 4

■ no-license = 5

■ link-up = 6

■ hardware-failure = 7

■ software-failure = 8

■ error-disabled = 9

■ sfp-not-present = 10

Rcv errors

Recv Pause pause

Resets resets

Single Collision errors

SQETest errors

Symbol errors

Total Bytes(Rx) Bytes

Total Bytes(Tx) Bytes

Total Packets (Rx) packets

Total Packets (Tx) packets

Under Size errors

Unicast Packets (Rx) packets

Unicast Packets (Tx) packets

Xmit errors

Page 94: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

94 cisco_ucs Guide

Monitor Name Units Description

Xmit Pause pause

Application.Cisco_UCS.FabricInterconnect.IOModule.FCPort

Administrative State Type: fabricAdminState

The potential values can be:

■ enabled = 0

■ disabled = 1

Bytes Rx Bytes

Bytes Tx Bytes

CRC Rx errors

Discard Rx errors

Discard Tx errors

Link Failures errors

Overall Status Type: networkPortOperState

The potential values can be:

■ indeterminate = 0

■ up = 1

■ admin-down = 2

■ link-down = 3

■ failed = 4

■ no-license = 5

■ link-up = 6

■ hardware-failure = 7

■ software-failure = 8

■ error-disabled = 9

■ sfp-not-present = 10

Packets Rx Packets

Packets Tx Packets

Rx errors

Signal Losses errors

Sync Losses errors

Too Long Rx errors

Page 95: Nimsoft Monitor cisco ucs Guidedocs.nimsoft.com/prodhelp/en_US/Probes/Catalog/cisco_ucs/1.5/cisco...The cisco_ucs probe is capable of monitoring the state of VMWare ESX Hypervisors

Message Pool

Chapter 3: cisco_ucs Metrics 95

Monitor Name Units Description

Too Short Rx errors

Tx errors

Application.Cisco_UCS.FabricInterconnect.LocalStorage

bootflash(size) MB

bootflash(used) MB

opt(size) MB

opt(used) MB

workspace(size) MB

workspace(used) MB

Note: In the case of Application.Cisco_UCS.FabricInterconnect.LocalStorage, the names of the storage-partitions may vary as per the hardware; however bootflash, opt and workspace are the ones most commonly found.

Application.Cisco_UCS.Hypervisor

status Type: vmStatus

The potential values can be:

■ unknown = 0

■ online = 1

■ offline = 2

Application.Cisco_UCS.VirtualMachines

status Type: vmStatus

The potential values can be:

■ unknown = 0

■ online = 1

■ offline = 2