NGS data format and General Quality Control

13
NGS data format and General Quality Control

description

NGS data format and General Quality Control. Data format “Flowchart”. Fastq file. Used to record raw reads coming off the sequencers Each record contains four lines Parameters were usually set by the sequencer, such as read length. Fastq file . - PowerPoint PPT Presentation

Transcript of NGS data format and General Quality Control

Page 1: NGS data format and  General Quality Control

NGS data format and General Quality Control

Page 2: NGS data format and  General Quality Control

Data format “Flowchart”

Sequencer raw data Fastq SAM/BAM

Page 3: NGS data format and  General Quality Control

Fastq file

• Used to record raw reads coming off the sequencers

• Each record contains four lines• Parameters were usually set by the sequencer,

such as read length

Page 4: NGS data format and  General Quality Control

Fastq file

Page 5: NGS data format and  General Quality Control

• Line 1 begins with a '@' character and is followed by a sequence identifier and an optional description (like a FASTA title line).

• Line 2 is the raw sequence letters. The read length is the length of the string.

• Line 3 begins with a '+' character and is optionally followed by the same sequence identifier (and any description) again.

• Line 4 encodes the quality values for the sequence in Line 2, and must contain the same number of symbols as letters in the sequence.

http://en.wikipedia.org/wiki/FASTQ_format

Page 6: NGS data format and  General Quality Control

General quality control of raw reads

• Using FASTQC– A tool that implements some general rules– Basic Statistics– Per base sequence quality– Per sequence quality scores– Per base sequence content– Per base GC content– Per sequence GC content– Per base N content– Sequence Length Distribution– Sequence Duplication Levels– Overrepresented sequences– Kmer Content

Page 7: NGS data format and  General Quality Control

Quality scores

Page 8: NGS data format and  General Quality Control

Perbase “N” percentage

Page 10: NGS data format and  General Quality Control

Data format “Flowchart”

Sequencer Fastq SAM/BAM

Page 11: NGS data format and  General Quality Control

SAM/BAM

• SAM stands for Sequence Alignment Map• BAM is the binary form of SAM• Used for mapped/aligned reads• Generated by NGS mapper/aligners

Page 12: NGS data format and  General Quality Control

SAM

Page 13: NGS data format and  General Quality Control

BAM