Neonatal care - Eurocare

16
Neonatal care by Armstrong Medical 1

Transcript of Neonatal care - Eurocare

Page 1: Neonatal care - Eurocare

Neonatal careby Armstrong Medical

1

Page 2: Neonatal care - Eurocare

AquaVENT® NEO bespoke kits are designed to promote safer practice and convenience for the healthcare professional, helping reduce waste and inventory costs. Protected by BioCote®, AquaVENT® NEO breathing circuits offer improved hygiene.

Resuscitation

Transportation

InvasiveVentilation

AquaVENT® NEO

Neonatal CareAquaVENT® NEO breathing circuits are available for the

following therapies.

2

Page 3: Neonatal care - Eurocare

High flow

nCPAP

AquaVENT® NEO Optimal humidificationFlowkit/BioCote® Resuscitation nCPAP circuits Invasive ventilation High flow oxygen therapyTransportationFlowkitAccessoriesProduct codes

p2-3p4p5p6-7p8-9p10p11p12p13p14p15

ContentsNeonatal Care

3

Page 4: Neonatal care - Eurocare

Optimal Humidification

AquaVENT® NEO heated breathing circuits combine technological advances in thermal conductivity and breathing circuit construction to deliver optimal and controlled humidification.

4

Page 5: Neonatal care - Eurocare

AquaVENT® heated breathing circuits contain BioCote® antimicrobial silver additive to limit the numbers of microbes on the surface of the breathing circuit, protecting it from microbial colonisation.

Protected by BioCote®

Treated polymer (Containing BioCote®)

Untreated polymer (Not containing BioCote®)

Microscopy showing viable Pseudomonas aeruginosa cells as green-coloured and dead Pseudomonas aeruginosa cells as red-coloured.

BioCote® antimicrobial protection is effective against a broad spectrum of micro-organisms:

• Clostridium difficile• Legionella pneumophila• MRSA• Pseudomonas aeruginosa• Salmonella entertidis

• Salmonella typhimurium• Staph aureus• Vancomycin Resistant

Enterococcus• Aspergillus niger

• Aspergillus brasiliensis• Candida albicans• Penicillium sp.• Influenza A H1N1

Reduce your time, cost and waste by designing your own Flowkit NEO circuit for safer transition between therapies.

Your Customised Flowkit NEO

Flowkit NEO

5

Page 6: Neonatal care - Eurocare

NeoFlow resuscitation circuits can be supplied with face masks(1), O2 connecting tube and O2 analyser T-piece(2), and include a universal connection for all common devices(3).

Our NeoFlow blender and Blender Buddy can be connected to any neonatal resuscitator for accurate control of flow and O2 concentration(4). In line oxygen analyser allows for accurate O2 monitoring(5).

The dual flow meter configuration with 0-3l and 0-15l options makes NeoFlow extremely versatile and can be used for Resuscitation, High flow, Low flow and Bubble CPAP(6).

Resuscitation

1

4

3

2NeoFlow resuscitation circuits contain BioCote® antimicrobial

silver additive to limit the number of microbes on the surface of the

breathing circuit, protecting it from microbial colonisation(7).

5

7

6

6

Page 7: Neonatal care - Eurocare

24.0

22.0

20.0

18.0

16.0

14.0

12.0

10.0

8.0

6.0

4.0

2.0

0.0

PIP

(cm

H20

)

0 20% 50% 75% 100% Cap fully CLOSED and bleed hole fully

occluded

Cap fully OPEN and bleed hole fully

occluded

PIP cap closure (% rotation) (0=fully open, 100% = fully closed)

NeoFlow

PIP

(cm

H20

)

0.0 3.6 5.3 11.8 14.7 19.8 5.0

Cap fully CLOSED and

bleed hole fully occluded

Cap fully OPEN and bleed

hole fully occluded

PIP cap closure (cmh20) (0=fully open, 100% = fully closed

Positive inspiratory pressure

PIP cap rotation

Effect of cap rotation on positive inspiratory pressure

The NeoFlow resuscitation circuits include accurate and tactile PEEP control. The tubing construction has enhanced flexibility to prevent kinking and aid handling of the circuit.

NeoFlow mask

For more information on

NeoFlow for transport please

see page 12.

Our mask design has enhanced stability which helps in preventing inward collapse.

7

Page 8: Neonatal care - Eurocare

AquaVENT® NEO nCPAP circuits are available for leading flow drivers. If multiple flow drivers are in a department, adapter kits can be included to help reduce cost associated with increased stock holding.

nCPAP Circuits

nCPAP Flowkit optionsUse base code AMCP1409/044 and select from options a,b and c to customise your nCPAP Flowkit.

(a) Ventilator Adapters

Acutronic Fabian

Viasys Bear

Heinen + Löwenstein Leoni, Leoni PLUS

Carefusion SIPAP

Base Code AMCP1409/044

Circuit

Chamber

Humidification limb

Pressure line

Inspire Generator

Baffle Filter

Auto-fill humidification chamber with 1.2m feed line

1.8m pressure line

AquaVENT® 1.2m heated with 0.3m detachable and non-heated incubator limb with connector for nCPAP generator (IHCA600)

3 x nasal prongs for Sipap and Fabian

Baffle filter for IHCA600

Humidification limb 0.6m for infant flow

AquaVENT®

8

Page 9: Neonatal care - Eurocare

(c) Interface Options

nCPAP generator +/- nasal prongs + masks for Dräger/Hamilton/ Medin/

SIPAP

Neoflow high flow nasal cannula (Includes circuit connector)

Connector for Westmed, Ram and FP high flow nasal cannula

(b) Circuit Options

Detachable nCPAP connector for transition to high flow

With or without detachable incubator limb

High flow transition kit

Invasive ventilation transition kit

Nitric oxide connectors

Bubble CPAP circuit

9

Page 10: Neonatal care - Eurocare

AquaVENT® NEO ventilator circuits are available with either single or double heated wire limbs. Single heated wire circuits include our double seal water trap on the expiratory limb.

Ventilator adapters

Acutronic Fabian

Dräger Babylog®

Leoni, Leoni mobile

Viasys Bear Cub

Dräger reusable flow sensor

Circuit options

Dual heated for SLE 2000, 2000 HFO, 4000/5000

Dual heated Low flow circuits including nitric oxide adapters and detachable incubator limb 0.3 - 4L/min

High frequency oscillation breathing system

Single heated with expiratory water trap for SLE 2000, 2000 HFO, 4000/5000

Circuit OptionsSingle heated circuits

Dual heated circuits

Invasive Ventilation

Aeroneb solo neonatal adapters

Nitric oxide adapter kit

Test lung

Accessories

AquaVENT®

10

Page 11: Neonatal care - Eurocare

AquaVENT® NEO high flow circuits can be created for easy transition to and from nCPAP, bubble CPAP or invasive ventilation.

High flow

High Flow Oxygen Therapy

AMNC1001(Premature)

AMNC1002(Neonatal)

AMNC1003(Infant)

AMNC1004(Large Infant)

AMNC1005(Paediatric)

1-10L

1-10L

1-8L

NeoFlow nasal cannula deliver greater flow rates compared to standard cannula.

NeoFlow nasal cannula is a Phthalate free nasal cannula.

NeoFlow

Safety T-piece

Flowkit NEO

High flow transition kit

AquaVENT®

6L 6L

7L 7L

8L

= Standard cannula flow ratesKey

1-13L

1-8L

11

Page 12: Neonatal care - Eurocare

Non-heated ventilator circuits are available with a range of adapters for transportation equipment. Additional options available in your bespoke specification include connectors for delivery and measurement of NO, ventilator adapter kits and nasal prongs or masks for the delivery of non-invasive therapies.

Transport Ventilation

Transportation

NeoFlow for transportation

Transport breathing circuits (non-heated) for Leoni mobile/Babylog®

2000 1.9m (Other lengths available)

Transport Circuits

NeoFlow for transport enables the delivery of mask or prong nCPAP via a resuscitation unit for short term transport.

12

Page 13: Neonatal care - Eurocare

1. Consultation

2. Design your Flowkit NEO

3. Initial code and drawing for confirmation

Contact your Armstrong Medical representative to arrange your consultation.

Reduce your time, cost and waste by designing your own Flowkit NEO circuit for safer transition between therapies.

Flowkit NEO

4. Your unique CE marked Flowkit NEO for clinical evaluation

Our unique Flowkit NEO programme offers unrivalled delivery and support to the highest global standards.

Flowkit NEO

Before

After

13

Page 14: Neonatal care - Eurocare

Controlling the feed of water to the chamber reduces the time to reach set temperature, allowing users to initiate therapy sooner and improves patient comfort.

Key Features

Invasive or non-invasive mode selection

Digital displayOver-temperature protection. Low and high temperature alarms

Automatic temperature selection

Servo control

The AquaVENT® NEO humidification chamber delivers controlled and consistent humidity.

Accessories

Code Description Time to fill (s)

AMCA1141

AMCA1142

AMCA1145

AMCA1146

Auto-feed humidification chamber

Auto-feed humidification chamber with convection float

Humidification chamber with fast flow auto-feed set

Humidification chamber with fast flow auto-feed set and convection float

660

660

51

51

14

Page 15: Neonatal care - Eurocare

Product Codes

15

Page 16: Neonatal care - Eurocare

Distributed by:

Armstrong manufacture a complete range of disposable respiratory products

for anaesthesia and critical care applications. For supply of these products or any

product within the Armstrong range, please contact your local representative.

Armstrong Medical Wattstown Business Park Newbridge Road Coleraine BT52 1BS Northern Ireland T +44 (0) 28 7035 6029 F +44 (0) 28 7035 6875 E [email protected] W www.armstrongmedical.net

AMVCAQUA_NEO_V3