Near Term Convective Precipitation Forecasting using Real ... · sports, and outdoor entertainment...
Transcript of Near Term Convective Precipitation Forecasting using Real ... · sports, and outdoor entertainment...
![Page 1: Near Term Convective Precipitation Forecasting using Real ... · sports, and outdoor entertainment . Schneider Electric - Division - Name – Date 3 ... minimum threshold acceptable](https://reader033.fdocuments.in/reader033/viewer/2022042021/5e784021cd513f77576f7710/html5/thumbnails/1.jpg)
Near Term Convective Precipitation Forecasting using Real-Time Lightning Data, Observations, and
Radar
![Page 2: Near Term Convective Precipitation Forecasting using Real ... · sports, and outdoor entertainment . Schneider Electric - Division - Name – Date 3 ... minimum threshold acceptable](https://reader033.fdocuments.in/reader033/viewer/2022042021/5e784021cd513f77576f7710/html5/thumbnails/2.jpg)
Schneider Electric 2 - Division - Name – Date
Schneider Electric – A Provider of Business Weather Solutions
Aviation § Aviation Forecasting for commercial,
corporate, and specialized flight operations
§ Helicopter Decision Support Systems
§ Pavement Forecasting and alerting services for state and local government
§ Weather for Intelligent Transportation Systems (e.g. 511)
Transportation
§ Load Forecasting and alerting services for electric/gas utilities and renewables
§ Transmission and Distribution Crew Management
§ Wind Farm Safety
Energy Commercial § Custom Forecasting for weather
sensitive businesses –construction, sports, and outdoor entertainment
![Page 3: Near Term Convective Precipitation Forecasting using Real ... · sports, and outdoor entertainment . Schneider Electric - Division - Name – Date 3 ... minimum threshold acceptable](https://reader033.fdocuments.in/reader033/viewer/2022042021/5e784021cd513f77576f7710/html5/thumbnails/3.jpg)
Schneider Electric 3 - Division - Name – Date
50 Meteorologists based in Minneapolis, Minnesota provide 24/7 support
![Page 4: Near Term Convective Precipitation Forecasting using Real ... · sports, and outdoor entertainment . Schneider Electric - Division - Name – Date 3 ... minimum threshold acceptable](https://reader033.fdocuments.in/reader033/viewer/2022042021/5e784021cd513f77576f7710/html5/thumbnails/4.jpg)
Schneider Electric 4 - Division - Name – Date
![Page 5: Near Term Convective Precipitation Forecasting using Real ... · sports, and outdoor entertainment . Schneider Electric - Division - Name – Date 3 ... minimum threshold acceptable](https://reader033.fdocuments.in/reader033/viewer/2022042021/5e784021cd513f77576f7710/html5/thumbnails/5.jpg)
Schneider Electric 5 - Division - Name – Date
Goal to Improving the Near Term Precipitation Forecast
● Significantly reduce missed precipitation events happening now or are nearly imminent ● Quantitatively and qualitatively improve accuracy ● Reduce over-forecasting ● Reduce manual precipitation forecast editing that cover for model deficiencies
● NWS AWIPS Graphical Forecast Editor (GFE) employed for such forecaster modification
● Improve accuracy of precipitation type ● Snow ● Rain ● Freezing rain ● Thunder
● Improve downstream products that use the general weather forecast such as: ● Airport Terminal Forecasts ● Automated Alerting for Transportation, Construction, Sports, Utilities, etc..
![Page 6: Near Term Convective Precipitation Forecasting using Real ... · sports, and outdoor entertainment . Schneider Electric - Division - Name – Date 3 ... minimum threshold acceptable](https://reader033.fdocuments.in/reader033/viewer/2022042021/5e784021cd513f77576f7710/html5/thumbnails/6.jpg)
Schneider Electric 6 - Division - Name – Date
Challenges with Near Term Precipitation Forecasting
● Assimilation and analysis of observations too slow ● Assimilation and analysis of observation used in freely available near term models are
not leveraged in a timely enough fashion to handle events that pop up during the lag period between timeliness of observation datasets versus when these observations are leveraged in the model data ● These events can be very impactful and in the warm season can be fairly widespread
● Manual Editing of Precipitation is Labor Intensive ● Forecast editors can find it extremely challenging making sure all events are covered
● The sheer volume can lead to missed events ● Trying to ensure there are no missed events, the forecaster can often over-forecast as insurance ● Amounts can be easily under/over done and potential flooding events not properly forecasted especially for rapidly developing/decaying convective outbreaks ● Takes the forecasters eye off of forecasting events for hours 6-12+ where the skill is potentially better served
![Page 7: Near Term Convective Precipitation Forecasting using Real ... · sports, and outdoor entertainment . Schneider Electric - Division - Name – Date 3 ... minimum threshold acceptable](https://reader033.fdocuments.in/reader033/viewer/2022042021/5e784021cd513f77576f7710/html5/thumbnails/7.jpg)
Schneider Electric 7 - Division - Name – Date
How to Overcome Model Lag with Current Precipitation Events?
● Use Observation/Remote Sensing Data Inputs such as: ● Surface Observations ● Radar Data ● Lightning Data
● Integrate the Observation/Remote Sensing Data into the Model Blend used in the Precipitation Forecast First Guess Field ● Use algorithms to approximate the additional precipitation necessary to
represent the worst case of all observational inputs but individually the minimum threshold acceptable given the value of the observation or remote sensing data
● Use Model Data in the Most Rapidly Updating input Model to leverage in Algorithms ● Quantity estimate ● Storm motion
![Page 8: Near Term Convective Precipitation Forecasting using Real ... · sports, and outdoor entertainment . Schneider Electric - Division - Name – Date 3 ... minimum threshold acceptable](https://reader033.fdocuments.in/reader033/viewer/2022042021/5e784021cd513f77576f7710/html5/thumbnails/8.jpg)
Schneider Electric 8 - Division - Name – Date
Case Study December 20th, 2012 18-21UTC
● Cold frontal event over the panhandle of Florida northward to Ohio ● Typical behavior for a cold frontal event for this time of year in this region ● Challenge on these events are often (not always) low bias for amounts and event speed, that is more often than not, faster than guidance
![Page 9: Near Term Convective Precipitation Forecasting using Real ... · sports, and outdoor entertainment . Schneider Electric - Division - Name – Date 3 ... minimum threshold acceptable](https://reader033.fdocuments.in/reader033/viewer/2022042021/5e784021cd513f77576f7710/html5/thumbnails/9.jpg)
Schneider Electric 9 - Division - Name – Date
1937UTC December 20th, 2012 Radar, Lightning, and Temperature
![Page 10: Near Term Convective Precipitation Forecasting using Real ... · sports, and outdoor entertainment . Schneider Electric - Division - Name – Date 3 ... minimum threshold acceptable](https://reader033.fdocuments.in/reader033/viewer/2022042021/5e784021cd513f77576f7710/html5/thumbnails/10.jpg)
Schneider Electric 10 - Division - Name – Date
Initial First Guess Blend of NAM and GFS Used by the Forecasters (in.) 18-21 UTC
December 20th, 2012
![Page 11: Near Term Convective Precipitation Forecasting using Real ... · sports, and outdoor entertainment . Schneider Electric - Division - Name – Date 3 ... minimum threshold acceptable](https://reader033.fdocuments.in/reader033/viewer/2022042021/5e784021cd513f77576f7710/html5/thumbnails/11.jpg)
Schneider Electric 11 - Division - Name – Date
Precipitation Forecast Modified by Forecaster (in.) 18-21UTC December 20th , 2012
![Page 12: Near Term Convective Precipitation Forecasting using Real ... · sports, and outdoor entertainment . Schneider Electric - Division - Name – Date 3 ... minimum threshold acceptable](https://reader033.fdocuments.in/reader033/viewer/2022042021/5e784021cd513f77576f7710/html5/thumbnails/12.jpg)
Schneider Electric 12 - Division - Name – Date
19 UTC December 20th, 2012 Radar Data (dBZ)
![Page 13: Near Term Convective Precipitation Forecasting using Real ... · sports, and outdoor entertainment . Schneider Electric - Division - Name – Date 3 ... minimum threshold acceptable](https://reader033.fdocuments.in/reader033/viewer/2022042021/5e784021cd513f77576f7710/html5/thumbnails/13.jpg)
Schneider Electric 13 - Division - Name – Date
19 UTC December 20th, 2012 Flash Density Data (strokes/10min)
![Page 14: Near Term Convective Precipitation Forecasting using Real ... · sports, and outdoor entertainment . Schneider Electric - Division - Name – Date 3 ... minimum threshold acceptable](https://reader033.fdocuments.in/reader033/viewer/2022042021/5e784021cd513f77576f7710/html5/thumbnails/14.jpg)
Schneider Electric 14 - Division - Name – Date
18-21 UTC December 20th, 2012 RAP Model Precipitation Forecast (in.)
![Page 15: Near Term Convective Precipitation Forecasting using Real ... · sports, and outdoor entertainment . Schneider Electric - Division - Name – Date 3 ... minimum threshold acceptable](https://reader033.fdocuments.in/reader033/viewer/2022042021/5e784021cd513f77576f7710/html5/thumbnails/15.jpg)
Schneider Electric 15 - Division - Name – Date
18-21UTC December 20th, 2012 Enhanced Precipitation Forecast (in.)
![Page 16: Near Term Convective Precipitation Forecasting using Real ... · sports, and outdoor entertainment . Schneider Electric - Division - Name – Date 3 ... minimum threshold acceptable](https://reader033.fdocuments.in/reader033/viewer/2022042021/5e784021cd513f77576f7710/html5/thumbnails/16.jpg)
Schneider Electric 16 - Division - Name – Date
20 UTC December 20th, 2012 Precipitation Observations with Coverage of
Forecast Precipitation
![Page 17: Near Term Convective Precipitation Forecasting using Real ... · sports, and outdoor entertainment . Schneider Electric - Division - Name – Date 3 ... minimum threshold acceptable](https://reader033.fdocuments.in/reader033/viewer/2022042021/5e784021cd513f77576f7710/html5/thumbnails/17.jpg)
Schneider Electric 17 - Division - Name – Date
18-21 UTC December 20th, 2012 Zoomed In Precipitation Forecast Enhanced by Lightning
Data (in.)
![Page 18: Near Term Convective Precipitation Forecasting using Real ... · sports, and outdoor entertainment . Schneider Electric - Division - Name – Date 3 ... minimum threshold acceptable](https://reader033.fdocuments.in/reader033/viewer/2022042021/5e784021cd513f77576f7710/html5/thumbnails/18.jpg)
Schneider Electric 18 - Division - Name – Date
21 UTC December 20th, 2012 Radar and 3 Hour Precipitation Observations
(http://www.wrh.noaa.gov/slc/gmap/)
![Page 19: Near Term Convective Precipitation Forecasting using Real ... · sports, and outdoor entertainment . Schneider Electric - Division - Name – Date 3 ... minimum threshold acceptable](https://reader033.fdocuments.in/reader033/viewer/2022042021/5e784021cd513f77576f7710/html5/thumbnails/19.jpg)
Schneider Electric 19 - Division - Name – Date
Summary
● The precipitation forecast enhancement scheme: ● Reduces missed events to the forecast end users that use our:
● Online web products ● Precipitation Alerting ● Aviation forecasts ● Any other forecast products using near term precipitation forecasts
● Reduces the amount of labor required to capture all the near term events ● Improves quantitative accuracy of near term events ● Allows the meteorologists to divert their attention to more value add
forecasting and consulting tasks
![Page 20: Near Term Convective Precipitation Forecasting using Real ... · sports, and outdoor entertainment . Schneider Electric - Division - Name – Date 3 ... minimum threshold acceptable](https://reader033.fdocuments.in/reader033/viewer/2022042021/5e784021cd513f77576f7710/html5/thumbnails/20.jpg)
Schneider Electric 20 - Division - Name – Date
Dan Lennartson Data Development and
Consultation Certified Consulting Meteorologist (CCM)
Questions?