NAF-LinkIT...1 NAF-LinkIT Quick Guide Fi 41.85-1(3)GB/SE 08.10 NAF-LinkIT Service...

20
1 NAF-LinkIT Quick Guide Fi 41.85-1(3)GB/SE 08.10 NAF-LinkIT Service manual/Servicemanual Quick Guide Content/Innehållsförteckning: English version: Page 2-10 Swedish version: Page 11-20

Transcript of NAF-LinkIT...1 NAF-LinkIT Quick Guide Fi 41.85-1(3)GB/SE 08.10 NAF-LinkIT Service...

Page 1: NAF-LinkIT...1 NAF-LinkIT Quick Guide Fi 41.85-1(3)GB/SE 08.10 NAF-LinkIT Service manual/Servicemanual Quick Guide Content/Innehållsförteckning: English version: Page 2-10 2 1.1

1

NAF-LinkIT Quick Guide

Fi 41.85-1(3)GB/SE08.10

NAF-LinkITService manual/Servicemanual

Quick GuideContent/Innehållsförteckning:English version: Page 2-10Swedish version: Page 11-20

Page 2: NAF-LinkIT...1 NAF-LinkIT Quick Guide Fi 41.85-1(3)GB/SE 08.10 NAF-LinkIT Service manual/Servicemanual Quick Guide Content/Innehållsförteckning: English version: Page 2-10 2 1.1

2

1.1 Confi guration

For further information on confi guration not included on this sheet, see catalogue sheets Fk 41.85(X)SE and Fi 41.85(X)GB.

1. IntroductionThese instructions are intended as a quick guide to mounting and setting up NAF LinkIT intelligent valve actuators on NAF Turnex pneumatic devices. They cover the following main points:· Mounting to device· Air and electrical connections· Confi guration using press buttons and display (or LEDs) on NAF Turnex actuator

2 Mounting on pneumatic actuators

2.1 Air supplyIt is very important that the air supply is free of dirt and moisture as per IEC 654-2 when the valve actuator is connected. Dirt and moisture may cause erratic operation and even damage to the unit.

2.2 Checking the position of the stemNB. When mounting, note that the fl at on the stem of the actuator (the bottom side) must always point towards the arrow that is cast into the underside of the housing. Seen from this position, the operating angle is ± 45°.

NAF-LinkIT 370991- Service manualQuick Guide

Fi 41.85-1(3)GB08.10

DescriptionIntroduction 1Mounting to pneumatic device 2Air connections 3Electrical connections 4Start-up 5LCD – menu structure 6Safety requirements 7

Arrow

Flat

Page 3: NAF-LinkIT...1 NAF-LinkIT Quick Guide Fi 41.85-1(3)GB/SE 08.10 NAF-LinkIT Service manual/Servicemanual Quick Guide Content/Innehållsförteckning: English version: Page 2-10 2 1.1

3

Connection on other makes

Direct mounting on NAF-Turnex

2.4 Mounting on other makes of actuators· Before mounting, ensure that the open and closed positions of the actuator are within ± 45° of the position of the fl at. Check how the fl at on the upper part of the spindle lines up with the housing instead. This facilitates checking.· Mount the valve positioner on the actuator using the mounting kit. NAF has a carrier pin in the form of a shaped metal pin. This connected to the hole in the stem of the valve actuator and mounts into the corresponding groove in the shaft of the device. · The socket-head cap screws are then tightened until the valve positioner is fi rmly mounted. · Lubricate the air connections with anti-cutting paste where air nipples with seals are used. NB. Do not use this type of paste if using e.g. Tefl on tape. · Mount the air hoses on the valve positioner and actuator.

3. Air connectionsFor directly operating valve direction, the valve opens on an increased signal.

On actuators size 0-3, the hoses to the actuator must be connected in parallel, see illustration. On actuators size 4-5, the hoses to the actuator must be crossed.

Connection for supply air

Connection output y2 Connection output y1

2.3 Mounting on NAF-Turnex pneumatic actuator· Before mounting, follow instructions on how the fl at on the stem lines up with the cast-in arrow in the housing, see 2.2.· Mount the valve actuator on the device. If the valve is closed or open, adjust the spindle (± 45°) so that the drive pin, which must be mounted with O-rings (for play-free movement) and its O-rings slide down the groove in the device. · The socket-head cap screws are then tightened until the valve actuator is fi rmly mounted. · Lubricate the air connections with anti-cutting paste where air nipples with seals are used. NB. Do not use this type of paste if using e.g. Tefl on tape.· Mount the air hoses to the valve positioner and the actuator.

Page 4: NAF-LinkIT...1 NAF-LinkIT Quick Guide Fi 41.85-1(3)GB/SE 08.10 NAF-LinkIT Service manual/Servicemanual Quick Guide Content/Innehållsförteckning: English version: Page 2-10 2 1.1

4

+ - + -+ - + -+ - + -+ - + -+ - + -+ - + -+ - + -+ - + -81 82 83 8481 82 83 8481 82 83 8481 82 83 84+ - + -

+ - + -+ - + -+ - + -+ - + -+ - + -+ - + -+ - + -+ - + -81 82 31 3281 82 31 3281 82 31 3281 82 31 32+ - + -+ - + -+ - + -

+ - + -+ - + -+ - + -+ - + -+ - + -+ - + -+ - + -+ - + -13 14 15 1613 14 15 1613 14 15 1613 14 15 16+ - + -+ - + -

11 1211 12+ - + - + - + -

+ -+ -+ -

Input 4 - 20 mA

11 1211 12+ - + - + - + -

+ -+ -+ -

For 370991-xP (Profi bus PA)and 370991-xQ (Foundation F.H1)

Bus connection according to IEC 1158-2 Supply voltage DC 9 - 32 V

Two binary input (370991-xxB)

4.1 Target valueFor 370991-xH (HART), -xD (Digital)

4. Electrical connections 4.2 Inductive limit switches370991-xxxT2-wire inductive trans-mitter according to DIN 19234 or NAMUR Supply voltage: T = 8V

4.3 ”Option Board” (Accessory)Two binary output (370991-xxP)

2-wire inductive transmitter accor-ding to DIN 19234 Supply voltage: DC 8 - 48 V

Binary inputs with internal feed for connection of transmitter or switches (Switch closed for normal operating condition)

Position feedback 4 - 20 mA and 1 Alarm-370991-xxQ)

+ - + -+ - + -+ - + -+ - + -+ - + -+ - + -+ - + -+ - + -41 42 51 5241 42 51 5241 42 51 5241 42 51 52+ - + -

Limit switch for Limit switch for Limit switch for open position

Limit switch for Limit switch for Limit switch for closed position

Alarm on small opening angle

Alarm on large opening angle

Alarm for output, confi gu-rable

Analog output signal 4-20 mA 2-cable system supply voltage DC 8 – 48V

370991-xxxW3-wire inductive trans-mitter according to DIN 19234 or NAMUR Supply voltage: W = 10-30V

Page 5: NAF-LinkIT...1 NAF-LinkIT Quick Guide Fi 41.85-1(3)GB/SE 08.10 NAF-LinkIT Service manual/Servicemanual Quick Guide Content/Innehållsförteckning: English version: Page 2-10 2 1.1

5

M 1 2 3 4

M 1 2 3 4

5.2 Confi guration and operation using push-buttons

with LCD display: with LED display:

In confi guration, the selected parameter/function is dis-played against a dark background. Multiple menus using the (UP) or (DOWN) buttons.

On the fi rst switching on, the following happens:For positioners that are ready for operation, press (M) once and then go to item 3 below.

1. Menu 9.8 “language menu” appears on the LCD display. Select the appropriate language and press (UP)+(DOWN) simultaneously to confi rm your selection.

1. Menu 9.8 “language menu” appears on the LCD display. Select the appropriate language and press (UP)+(DOWN) simultaneously to confi rm your selection.

On the fi rst switching on, the following happens:For positioners that are ready for operation, press (M) once and then go to item 3 below.

9.8 Language menu

9.8.3 Swedish

5. Start-up (confi guration using the push-buttons and LCDs/LEDs)

After mounting on the actuator and the air and electrical connections are made, the NAF LinkIT valve positioner can be started. 370991 can be confi gured/run by means of push-buttons and an LED/LCD display.

NB: remember that the valve will be operated by use of the push-buttons. Valve and actuator mountings will rotate so keep your fi ngers out of the valve and away from the device mountings.RISK OF PERSONAL INJURY!

5.1 Description of LCD Display Push-buttons Process parameter presentation

Process parameter presentation and alarm

Confi guration : Main menu

(M) Enter or back to main menu

(DOWN) Previous menu or para-meter

(UP) Next menu or parameter

9.8 Language9.8.1 English9.8.2 German9.8.3 Swedish

87.5 %Valve position

NAF-LinkIT Main menu1 Mounting2 Autostart3 Valve direction9.8.3 Swe9.8.3 Swedish

87.5 %Valve position

Control deviationM (Menu) Menu/close menu

UP / Down Change menu or parameters

UP + DOWN simultaneously: Confi rm command, e.g. on enter, store or verify.

M + UP + DOWN Restart 1)

simultaneously:

1) All data stored in NAF LinkIT is unaffected by this and remains unchanged.

Page 6: NAF-LinkIT...1 NAF-LinkIT Quick Guide Fi 41.85-1(3)GB/SE 08.10 NAF-LinkIT Service manual/Servicemanual Quick Guide Content/Innehållsförteckning: English version: Page 2-10 2 1.1

6

M 1 2 3 4

M 1 2 3 4

M 1 2 3 4

M 1 2 3 4

*

M 1 2 3 4

*

M 1 2 3 4

M 1 2 3 4

M 1 2 3 4When the Autostart is complete, return to the opera-ting condition by pressing (M) once.

The unit is now confi gured and in operation.

3.

9.9 LCD orient

9.9.1 Normal

9.9.2 Change

2.1 Limit position cal.

2.2 Standard

2 Autostart

When the Autostart is complete, return to the opera-ting condition by pressing (M) once.

”Operating condition”

The unit is now confi gured and in operation.

2. Menu 9.9 “LCD orient” now appears. Select the orientation with the (UP) or (DOWN) button. Confi rm your selection by pressing (UP)+(DOWN) simultaneous-ly.

2. Menu 9.9 “LCD orient” now appears. Select the orientation with the (UP) or (DOWN) button. Confi rm your selection by pressing (UP)+(DOWN) simultaneously.

3. Press (M) to go to the main menu.

4. Select menu 2, “Autostart ”. Confi rm by pressing (UP)+(DOWN) simultaneously. Then select 2.2 “Standard” (or one of the other options). Execute the selection by pressing (UP)+(DOWN) simultaneously.

4. Select menu 2, “Autostart ”. Confi rm by pressing (UP)+(DOWN) simultaneously. Then select 2.2 “Standard” (or one of the other options). Execute the selection by pressing (UP)+(DOWN) simultaneously.

9.9 LCD Orient9.9.1 Normal9.9.2 Change

NAF-LinkIT Main menu1 Mounting2 Autostart3 Valve direction4 Characteristics5 Limits/alarm

2 Autostart2.1 Limit position2.2 Standard2.3 Enhanced2.4 Gentle2.5 Abrupt

87.5 %Valve position

NAF-LinkIT Main menu1 Mounting2 Autostart3 Valve direction4 Characteristics5 Limits/alarm

Page 7: NAF-LinkIT...1 NAF-LinkIT Quick Guide Fi 41.85-1(3)GB/SE 08.10 NAF-LinkIT Service manual/Servicemanual Quick Guide Content/Innehållsförteckning: English version: Page 2-10 2 1.1

7

6. LCD - Menu structure

NAF-LinkIT Main Menu

Menu Factory Descriptionconfiguration

1 Mounting1.1 Lin left Linear actuator, left-hand or direct mounting1.2 Lin right Linear actuator, right-hand mounting1.3 Rot cclockw Rotary actuator, opening counter-clockwise1.4 Rot clockw Rotary actuator, opening clockwise

2 Autostart 2.1 FuEndpoinds Adaption to the mechanical stops only2.2 Standard Autostart rtecommendedfor standard application2.3 Enhanced Optimized control behaviour compared to Standard Autostart2.4 Smooth Resp. Extended Autostart, dampenend control behaviour for

e.g. smaller actuators2.5 Fast Resp. Extended Autostart, undampenend control behaviour for

e.g. larger actuators

3 Valve Action3.1 Direct Valve opens with increasing setpoint value3.2 Reverse Valve closes with increasing setpoint value

4 Character4.1 Linear Linear characteristic 4.2 Eq Perc 1:50 Equal percentage characteristic 1:504.3 Quick open Inverse equal percentage characteristic 1:50 (quick opening)4.4 Customer Custom characteristic

5 Limits/alarms Not locally available with communication FF and Profibus5.1 Lower limit 0% Closing limit5.2 Cutoff low 0% 0%-tight sealing point5.3 Cutoff high 100% 100%-tight sealing point5.4 Upper limit 100% Opening limit5.5 Splitr 0 % 4mA Split range 0 %: input value corresponds to 0 %5.6 Splitr 100 % 20mA Split range 100 %: input value corresponds to 100 %5.7 Lower Alarm -10% Lower position alarm on output 15.8 Upper Alarm 110% Upper position alarm on output 25.9 Valve 0% 0% Configuration of rated-stroke of 0% at 4 mA5.10 Valve 100% 100% Configuration of rated-stroke of 100% at 20 mA5.11 Stroke range 90.8° Configuration of nominal travel (rotary shows range from autostart,

not config)5.12 Temp Unit °C Configuration of the temperature unit °C or °F

5.12.1 °C Temperature in °C5.12.2 °F Temperature in °F

6 Parameters6.1 Gain closing 3,5 P: Proportional amplification for ‘close valve’6.2 Gain opening 3,5 p: Proportional amplification for ‘open valve’6.3 Res time cl 15 I: Integration time for ‘close valve’6.4 Res time op 15 I: Integration time for ‘open valve’6.5 Rate lim cl 0 T63: Setting time for ‘close valve’6.6 Rate lim op 0 T63: Setting time for ‘open valve’6.7 Control gap 0 Permitted neutral zone for control difference

Page 8: NAF-LinkIT...1 NAF-LinkIT Quick Guide Fi 41.85-1(3)GB/SE 08.10 NAF-LinkIT Service manual/Servicemanual Quick Guide Content/Innehållsförteckning: English version: Page 2-10 2 1.1

8

6. LCD - Menu structure (cont.)

7 Output Manual setting of IP-Module for testing of pneumatic output

8 Setpoint Manual setting of valve position8.1 12.5% Steps Setpoint changes of 12.5% steps by pushing buttons Up or Down8.2 1% Steps Setpoint changes of 1% steps by pushing buttons Up or Down

9 Workbench 9.1 Reset Config Resetting of configuration to setting “ex factory”9.2 Calib. 4 mA Calibrate input current to 4 mA9.3 Calib. 20 mA Calibrate input current to 20 mA9.4 Calib. -45° Calibrate position measuring value to –45°9.5 Calib. +45° Calibrate position measuring value to +45°9.6 Reset all 1 Resetting of configuration and Calibration (!) to “ex factory” setting

for single-acting output9.7 Reset all 2 Resetting of configuration and Calibration (!) to “ex factory” setting

for double-acting output9.8 Menu Lang

9.8.1 English Standard9.8.2 Deutsch Standard9.8.3 Français Preselected / Freely Defiable

9.9 LCD orient9.9.1 Normal Normal orientation of writing on LCD9.9.2 Flipped Reverse orientation of writing on LCD

9.10 Cal. Feedback9.10.1 Cal 4 mA Calibration of 0% at 4 mA 9.10.2 Cal 20 mA Calibration of 100% at 20 mA

10 - not available - for HART

10 Bus adresse - Profibus PA10.1 Address LSB Ratio from Dec. 0 / Hex 00 to Dec. 15 / Hex 0F10.2 Address MSB Ration from Dec. 0 / Hex 00 to Dec. 112 / Hex 7010.3 Address 126 Display of Bus Address from Dec. 1 to 127 (Hex 00 to 7F)

10 FF Config10.1 Simulate Disabled Simulate disabled Enabled Simulate enabled10.2 Profile Linkmaster Link Master active Basic device Link Master de-active

Page 9: NAF-LinkIT...1 NAF-LinkIT Quick Guide Fi 41.85-1(3)GB/SE 08.10 NAF-LinkIT Service manual/Servicemanual Quick Guide Content/Innehållsförteckning: English version: Page 2-10 2 1.1

9

7 Output Manual setting of IP-Module for testing of pneumatic output

8 Setpoint Manual setting of valve position8.1 12.5% Steps Setpoint changes of 12.5% steps by pushing buttons Up or Down8.2 1% Steps Setpoint changes of 1% steps by pushing buttons Up or Down

9 Workbench 9.1 Reset Config Resetting of configuration to setting “ex factory”9.2 Calib. 4 mA Calibrate input current to 4 mA9.3 Calib. 20 mA Calibrate input current to 20 mA9.4 Calib. -45° Calibrate position measuring value to –45°9.5 Calib. +45° Calibrate position measuring value to +45°9.6 Reset all 1 Resetting of configuration and Calibration (!) to “ex factory” setting

for single-acting output9.7 Reset all 2 Resetting of configuration and Calibration (!) to “ex factory” setting

for double-acting output9.8 Menu Lang

9.8.1 English Standard9.8.2 Deutsch Standard9.8.3 Français Preselected / Freely Defiable

9.9 LCD orient9.9.1 Normal Normal orientation of writing on LCD9.9.2 Flipped Reverse orientation of writing on LCD

9.10 Cal. Feedback9.10.1 Cal 4 mA Calibration of 0% at 4 mA 9.10.2 Cal 20 mA Calibration of 100% at 20 mA

10 - not available - for HART

10 Bus adresse - Profibus PA10.1 Address LSB Ratio from Dec. 0 / Hex 00 to Dec. 15 / Hex 0F10.2 Address MSB Ration from Dec. 0 / Hex 00 to Dec. 112 / Hex 7010.3 Address 126 Display of Bus Address from Dec. 1 to 127 (Hex 00 to 7F)

10 FF Config10.1 Simulate Disabled Simulate disabled Enabled Simulate enabled10.2 Profile Linkmaster Link Master active Basic device Link Master de-active

7. Safety requirements for NAF-LinkIT 370991

Technical data for Explosion Protection: See EU-Certifi cate of Conformity and Product Specifi cations.

EU-Certifi cate of Conformity: PTB 00 ATEX 2128 for 370991

The positioner must be installed and operated only by qualifi ed person-nel, familiar with commissioning and operating of the product!

Accident preventionThe connected instrument contains mechanically moved parts, e.g. feed-back lever which could cause injuries. The operators have to be instructed accordingly.

Electrical safetyThe instrument satisfi es the safety conditions according to EN 61010-1 (or IEC 1010-1), Safety Class III, Overload Category I. Any work on electrical parts must be done by qualifi ed personnel, if any power supply is connected to the instrument. The instrument has to be used for its designated pupose and connected in accordance with its wiring diagram.- National application regulations for electrical equipment have to be adhered too. The instrument has to be operated with safety extra-low voltage SELV or SELV-E. Safety precautions taken in the instrument may be rendered ineffectual if the instrument is not operated in accordance with the instructions. Limitation of power supply for fi re protection must be adhered to according to EN 61010-1, Appendix F (or IEC 1010-1).

Electrical Classifi cation, Maintenance of Ex-instrumentsFor installation in contact with explosive atmospheres, all relevant national and installation regulations must be adhered to. Attention: When repairing or altering explosion-protected equipment, natio-nal regulations must be adhered to. For maintenance and repairs involving parts, use only manufacturer’s original parts.

EMC and CEFor notes regarding Electromagnetic Compatibility EMC and for CE label identifi cation, see product specifi cation sheet. To ensure EMC protection, the electronic cover must be screwed to the housing.

Electrical ConnectionsFor installation and operation in explosion hazardous areas, the applicable national regulations have to be adhered to. For connection of the intrinsi-cally safe circuits, the rquirements of the EU-Certifi cate of Conformity are applicable. Unused insert holes for cable glands should be closed off tightly with blind dummy plugs.

Applicable especially for NAF-LinkIT 370991-xP Profi bus PositionerIf the positioner is connected to additional instruments, the FISCO model should thereby be used as a basis, the connection requriements according to PNO Profi bus PA User and Installation Guideline (Version 2.2) have to be observed. If this does not apply, the regulations for certifi ed circuit con-nection according to PTB-Report PTB-ThEx-10 are applicable and must be adhered to.

Page 10: NAF-LinkIT...1 NAF-LinkIT Quick Guide Fi 41.85-1(3)GB/SE 08.10 NAF-LinkIT Service manual/Servicemanual Quick Guide Content/Innehållsförteckning: English version: Page 2-10 2 1.1

10

7. Safety requirements for NAF-LinkIT 370991 (cont.)

Warning: Notice for option Limit SwitchOption ”Limit switch” (370991-xxxT, U or V. Danger of injuries: Do not touch control vanes during operation!

Warning: Notice for option Limit Switch with micro-switches connected to high voltageFor the positioners or position transmitters with option ”Limit Switch with micro-switches” 370991-xxxV provide an over current protection of fuse 2,5A for the connection of microswitches. The micro-switches must be connected to an isolation that allows to disconnect the power source from the micro-switches like described in the EN 61010-1 directive paragraph 6.12.

Warning: Notice for NAF-LinkIT (all versions)Programming via the programming plug can only be performed in non-explo-sive atmospheres, otherwise the intrinsic safety is rendered ineffectual.To avoid damage of ex-relevant component parts, a suitable galvanically separa-ted program adapter must be used.

Further product information is available via internet: www.naf.se

Page 11: NAF-LinkIT...1 NAF-LinkIT Quick Guide Fi 41.85-1(3)GB/SE 08.10 NAF-LinkIT Service manual/Servicemanual Quick Guide Content/Innehållsförteckning: English version: Page 2-10 2 1.1

11

1.1 Konfi gurering

För ytterligare information om konfi gurering som ej nämns i detta blad, se katalogblad Fk 41.85(X)SE och Fi 41.85(X)GB.

1. InledningDenna instruktion är avsedd att vara en snabb guide för montage och igångsättning av NAF-LinkIT intelligent ventillägesställare på NAF-Turnex penumatiska don. Instruktionen täcker in följande huvudpunkter:- Montering på don- Luft- och elektriska anslutningar- Konfi gurering med hjälp av tryckknappar och display (eller lysdioder) på NAF-Turnex don

2 Montering på pneumatiska don

2.1 MatningsluftDet är mycket viktigt att matningsluften är smuts- och fuktfri enligt IEC 654-2 när man ansluter ventillägesställaren. Smuts och fukt kan förorsaka driftstörningar och även haverier av enheten.

2.2 Kontroll av spindelns riktningOBS! Vid montering observera att den plana sidan på ställarens spindel (bottensida) alltid skall vara riktad mot pilen som fi nns ingjuten i husets bottensida. Arbetsvinkeln sett från denna position är ± 45°.

NAF-LinkIT Ventillägesställare370991- ServicemanualNAF-LinkIT Ventillägesställare370991- ServicemanualNAF-LinkIT VentillägesställareQuick Guide

Fi 41.85-1(3)SE08.10

Beskrivning Inledning 1Montering på pneumatiska don 2Luftanslutningar 3Elektriska kopplingar 4Start upp 5LCD - Menystruktur 6Säkerhetskrav 7

Pil

Planyta

Page 12: NAF-LinkIT...1 NAF-LinkIT Quick Guide Fi 41.85-1(3)GB/SE 08.10 NAF-LinkIT Service manual/Servicemanual Quick Guide Content/Innehållsförteckning: English version: Page 2-10 2 1.1

12

Koppling mot andra fabrikat

Direktmontage på NAF-Turnex don

2.4 Montering på andra donfabrikat- Innan montage, försäkra er om att donets öppna resp. stängda läge är inom ± 45° från den plana ytans läge. Kontrollera hur den plana ytan på spindelns övre del förhåller sig mot huset istället. Detta underlättar kontrollen.- Montera på ventillägesställaren med hjälp av montagesats på donet. NAF har en medbringarpinne i form av en formad metallpinne. Denna ansluts till ventillägesställarspindelns hål och passas in i donets motsvarande spår i donaxeln.- Därefter dras skruvar i bygel samt axel tills ventillägesställaren sitter ordentligt fast. - Smörj luftanslutningar med antiskärpasta då luftnipplar med tätningar används. OBS! Använd ej denna typ av pasta om man använder t ex tefl ontejp.- Montera på luftslangar på ventillägesställaren och donet.

3. LuftanslutningarFör direktverkande ventilriktning, ökad signal, ventil öppnar.

På manöverdon storlek 0-3 skall slangar till manöverdon vara parallellt kopplade, se bild.På manöverdon storlek 4 och 5 ska slangar till manöverdon vara korsade.

Anslutning för matningsluft

Anslutning utgång y2 Anslutning utgång y1

2.3 Montage på NAF-Turnex pneumatiska don- Innan montage, följ instruktionen om hur spindelns plana yta förhåller sig mot den ingjutna pilen i huset, se 2.2.- Montera på ventillägesställaren på donet. Om ventilen är stängd eller öppen, anpassa spindeln (± 45°) så att drivpinnen (skall vara försedd med o-ringar för glappfri rörelse) med dess O-ringar glider ned i spåret på donet. - Därefter dras insexskruvarna tills ventillägesställaren sitter ordentligt fast. - Smörj luftanslutningar med antiskärpasta då luftnipplar med tätningar används. OBS! Använd ej denna typ av pasta om man använder t ex tefl ontejp.- Montera på luftslangar på ventillägesställaren och donet.

Page 13: NAF-LinkIT...1 NAF-LinkIT Quick Guide Fi 41.85-1(3)GB/SE 08.10 NAF-LinkIT Service manual/Servicemanual Quick Guide Content/Innehållsförteckning: English version: Page 2-10 2 1.1

13

+ - + -+ - + -+ - + -+ - + -+ - + -+ - + -+ - + -+ - + -81 82 83 8481 82 83 8481 82 83 8481 82 83 84+ - + -

+ - + -+ - + -+ - + -+ - + -+ - + -+ - + -+ - + -+ - + -81 82 31 3281 82 31 3281 82 31 3281 82 31 32+ - + -+ - + -+ - + -

+ - + -+ - + -+ - + -+ - + -+ - + -+ - + -+ - + -+ - + -13 14 15 1613 14 15 1613 14 15 1613 14 15 16+ - + -+ - + -

11 1211 12+ - + - + - + -

+ -+ -+ -

Input 4 - 20 mA

11 1211 12+ - + - + - + -

+ -+ -+ -

För 370991-xP (Profi bus PA)och 370991-xQ (Foundation F.H1)

Bus anslutning enligt IEC 1158-2 Matningsspänning DC 9 - 32 V

Två binära ingångar (370991-xxB)

4.1 BörvärdeFör 370991-xH (HART), -xD (Digital)

4. Elektriska kopplingar 4.2 Induktiva ändlägeskontakter370991-xxxT2-tråds induktiva givare enligt DIN 19234 eller NAMUR Matningsspänning: T = 8V

4.3 ”Option Board” (Tillbehör)Två binära utgångar (370991-xxP)

2-tråds induktiva givare enligt DIN 19234 Matningsspänning: DC 8 - 48 V

Binära ingångar med intern matning för koppling av givare eller switchar(Switch stängd för läge normaldrift)

Lägesåterföring 4 - 20 mA och 1 Alarm-370991-xxQ)

+ - + -+ - + -+ - + -+ - + -+ - + -+ - + -+ - + -+ - + -+ - + -+ - + -41 42 51 5241 42 51 5241 42 51 5241 42 51 5241 42 51 52+ - + -

Ändlägeskontakt för Ändlägeskontakt för Ändlägeskontakt för Ändlägeskontakt för Ändlägeskontakt för Ändlägeskontakt för Ändlägeskontakt för Ändlägeskontakt för stängt lägeÄndlägeskontakt för Ändlägeskontakt för Ändlägeskontakt för Ändlägeskontakt för Ändlägeskontakt för Ändlägeskontakt för Ändlägeskontakt för Ändlägeskontakt för Ändlägeskontakt för Ändlägeskontakt för

öppet lägeÄndlägeskontakt för Ändlägeskontakt för Ändlägeskontakt för

Larm för liten öppnings-vinkel

Larm för stor öppnings-vinkel

Larm för utgång, konfi gurerbarLarm för utgång, Analog utsignal 4-20 mA

2-kabel system matningspänning DC 8 - 48 V

370991-xxxW3-tråds induktiva givare enligt DIN 19234 eller NAMUR Matningsspänning: W = 10-30V

STÄN

GTST

ÄNGT

ÖPPE

ÖPPE

ÖPPE

T

BLÅ

BLÅ

SVAR

T

SVAR

T

BRUN

Page 14: NAF-LinkIT...1 NAF-LinkIT Quick Guide Fi 41.85-1(3)GB/SE 08.10 NAF-LinkIT Service manual/Servicemanual Quick Guide Content/Innehållsförteckning: English version: Page 2-10 2 1.1

14

M 1 2 3 4

M 1 2 3 4

5.2 Konfi gurering och handhavande med tryckknappar (Snabbt komma i gång)

med LCD display: med LED display:

Vid konfi gurering är vald parameter/funktion visad med mörk bakgrund. Flera menyer med hjälp av (UP) eller (DOWN) knappen.

Vid 1:a spänningssättning sker följande:För ställare som är driftsatta tryck (M) en gång, gå sedan till punkt 3 nedan.

1. På LCD displayen kommer meny 9.8, ”Språkmeny” fram. Välj lämpligt språk och tryck (UP)+(DOWN) samtidigt för att bekräfta valet.

1. På LCD displayen kommer meny 9.8, ”Språkmeny” fram. Välj lämpligt språk och tryck (UP)+(DOWN) samtidigt för att bekräfta valet.

Vid 1:a spänningssättning sker följande:För ställare som är driftsatta tryck (M) en gång, gå sedan till punkt 3 nedan.

9.8 Språkmeny

9.8.3 Svenska

5. Uppstart (Konfi gurering med hjälp av tryckknapparna och LCD / LED:er)

Efter montering på don med luft, och elektriska anslutningar är kopplade, kan man starta upp NAF-LinkIT ventillägesställaren. 370991 kan konfi gureras/köras med hjälp av tryckknappar och LED/LCD display.

OBS: Tänk på att med hjälp av tryckknapparna kommer ventilen att manövreras. Ventil och donkopplingar kommer att rotera, så se upp med fi ngrar i ventilen samt kring donkopplingar. RISK FÖR PERSONSKADOR!

5.1 Beskrivning av LCD Display Tryckknappar Process parameterpresentation

Process parameter presentation och larm

Vid konfi gurering : Huvudmeny

(M) Enter eller tillbaka i huvudmeny

(DOWN) Föregående meny eller parameter

(UP) Nästa meny eller parameter

9.8 Language9.8.1 English9.8.2 German9.8.3 Swedish

87.5 %Ventilläge

NAF-LinkIT Huvudmeny1 Montage2 Autostart3 Ventilriktning9.8.3 Swe9.8.3 Swedish

87.5 %Ventilläge

Regleravvik.M (Meny) Meny/Avsluta meny

UP / Down Skifta meny respektive para- metrar

UP + DOWN samtidigt: Bekräfta kommando t ex vid enter, lagring eller verifi ering.

M + UP + DOWN samtidigt: Omstart 1)

1) All data som är lagrad i NAF-LinkIT påverkas inte av detta utan förblir oförändrad.

Page 15: NAF-LinkIT...1 NAF-LinkIT Quick Guide Fi 41.85-1(3)GB/SE 08.10 NAF-LinkIT Service manual/Servicemanual Quick Guide Content/Innehållsförteckning: English version: Page 2-10 2 1.1

15

M 1 2 3 4

M 1 2 3 4

M 1 2 3 4

M 1 2 3 4

*

M 1 2 3 4

*

M 1 2 3 4

M 1 2 3 4

M 1 2 3 4Efter att Autostarten är färdig återgå till driftläge genom att trycka (M) en gång.

Enheten är nu konfi gurerad och i drift.

3.

9.9 LCD orient

9.9.1 Normal

9.9.2 Vänd

2.1 Ändlägeskal.

2.2 Standard

2 Autostart

Efter att Autostarten är färdig återgå till driftläge genom att trycka (M) en gång.

”Driftläge”

Enheten är nu konfi gurerad och i drift.

2. Nu kommer menyn 9.9, ”LCD-orient” fram. Välj orientering genom (UP) eller (DOWN) knappen. Bekräfta valet genom att trycka (UP)+(DOWN) samtidigt.

2. Nu kommer menyn 9.9, ”LCD-orient” fram. Välj orientering genom (UP) eller (DOWN) knappen. Bekräfta valet genom att trycka (UP)+(DOWN) samtidigt.

3. Tryck (M) för att gå in i huvudmenyn.

4. Välj meny 2, ”Autostart”. Bekräfta genom att trycka (UP)+(DOWN) samtidigt. Välj sedan 2.2, ”Standard” (eller något av övriga alt). Verkställ valet genom att trycka (UP)+(DOWN) samtidigt.

4. Välj meny 2, ”Autostart”. Bekräfta genom att trycka (UP)+(DOWN) samtidigt. Välj sedan 2.2, ”Standard”. Verkställ valet genom att trycka (UP)+(DOWN) samtidigt.

9.9 LCD Orient9.9.1 Normal9.9.2 Vänd

NAF-LinkIT Huvudmeny1 Montage2 Autostart3 Ventilriktning4 Karaktäristik5 Gränser/Larm

2 Autostart2.1 Ändläge2.2 Standard2.3 Utökad2.4 Lugn2.5 Aggressiv

87.5 %Ventilläge

NAF-LinkIT Huvudmeny1 Montage2 Autostart3 Ventilriktning4 Karaktäristik5 Gränser/Larm

Page 16: NAF-LinkIT...1 NAF-LinkIT Quick Guide Fi 41.85-1(3)GB/SE 08.10 NAF-LinkIT Service manual/Servicemanual Quick Guide Content/Innehållsförteckning: English version: Page 2-10 2 1.1

16

NAF-LinkIT HuvudmenyMeny Fabriks Beskrivning

konfigurering1 Montage

1.1 Lin vänster Linjärt manöverdon, vänster sida eller direkt montage1.2 Lin höger Linjärt manöverdon, höger sida1.3 Rot moturs Roterande manöverdon, öppning moturs1.4 Rot medurs Roterande manöverdon, öppning medurs

2 Autostart 2.1 Ändläge Kalibrering av de mekaniska ändlägesstoppen (0-100%)2.2 Standard Rekommenderad Autostart för standardapplikationer2.3 Utökad Optimerade regleregenskaper jämfört med Standard Autostart2.4 Lugn Utökad autostart, Dämpat reglerbeteende för t.ex små manöverdon2.5 Aggressiv Utökad autostart, Odämpat reglerbeteende för t.ex stora manöverdon

3 Ventil riktn3.1 Direkt Ventil öppnar med stigande börvärde3.2 Omvänd Ventil stänger med stigande börvärde

4 Karakeristik4.1 Linjär Linjär karakteristik4.2 Procentuell Lik procentig karakteristik 1:504.3 Snabb öppna Snabböppnande 50:1 (Omvänd Lik procentig karakteristik 1:50)4.4 Kund spec Kundspecifik karakteristik

5 Gränser/Larm Ej lokalt tillgängliga med FF och PROFIBUS kommunikation5.1 Nedre gräns 0% Nedre gräns5.2 Cutoff 0% 0% 0%-cutoff5.3 Cutoff 100% 100% 100%-cutoff5.4 Övre gräns 100% Övre gräns5.5 Splitr 0 % 4mA Split range 0 %: ingående värde överensstämmer med 0 %5.6 Splitr 100 % 20mA Split range 100 %: ingående värde överensstämmer med 100 %5.7 Nedre larm -10% Låg larm på utgång 15.8 Övre larm 110% Hög larm på utgång 25.9 Ventil 0% 4mA Konfigurering av 0% vid 4 mA5.10 Ventil 100% 20mA Konfigurering av 100% vid 20 mA5.11 Arbetsområde 90.8° Konfigurering av arbetsområde (roterande visar värde från autostart,

ej konfig)5.12 Temp Enhet °C Konfigurering av temperatur enhet °C eller °F

5.12.1 °C Temperatur i °C5.12.2 °F Temperatur i °F

6 Parametrar6.1 P Först ST 3,5 P: Förstärkning för stäng-rörelse6.2 P Först ÖP 3,5 P: Förstärkning för öppnings-rörelse6.3 I Tid ST 15 I: Integrationstid för stäng-rörelse6.4 I Tid ÖP 15 I: Integrationstid för öppnings rörelse6.5 D Tid ST 0 T63: Inställningstid för stäng-rörelse6.6 D Tid ÖP 0 T63: Inställningstid för öppnings-rörelse6.7 Regler gap 0 Accepterad regleravvikelse

6. LCD - Menystruktur

Page 17: NAF-LinkIT...1 NAF-LinkIT Quick Guide Fi 41.85-1(3)GB/SE 08.10 NAF-LinkIT Service manual/Servicemanual Quick Guide Content/Innehållsförteckning: English version: Page 2-10 2 1.1

17

7 Utgång Manuell insällning av IP-modul för test av pneumatisk utgång.

8 Börvärde Manuell insällning av ventilläget8.1 12.5% Steg Ändring av börvärdet i steg om 12.5% genom att trycka

på "Up" och "Down"8.2 1% Steg Ändring av börvärdet i steg om 1% genom att trycka

på "Up" och "Down"9 Kalibrering

9.1 Reset Konfig Återställning av konfiguration till "fabriksinställning" 9.2 Kalib 4 mA Kalibrering ingående strömsignal till 4 mA 9.3 Kalib 20 mA Kalibrering ingående strömsignal till 20 mA9.4 Kalib -45° Kalibrering positionsmätning till -45°9.5 Kalib +45° Kalibrering positionsmätning till -45°9.6 Grundinst 1 Återställning av konfiguration och kalibrering till "fabriks

inställning" för enkelverkande manöverdon9.7 Grundinst 2 Återställning av konfiguration och kalibrering till "fabriks

inställning" för dubbelverkande manöverdon9.8 Språk meny

9.8.1 Engelska Standard9.8.2 Tyska Standard9.8.3 Svenska Valbart / Kontakta NAF för aktuella språk

9.9 LCD orient9.9.1 Normal Normalt vänd text på LCD´n9.9.2 Vänd Vänder texten 180° på LCD´n

9.10 Kal. Feedback9.10.1 Kal 4 mA Kalibrering av 0% vid 4 mA 9.10.2 Kal 20 mA Kalibrering av 100% vid 20 mA

10 - Ej tillgänglig för HART

10 Bus adress - Profibus PA10.1 Adress LSB Ratio från Dec. 0 / Hex 00 till Dec. 15 / Hex 0F10.2 Adress MSB Ration från Dec. 0 / Hex 00 till Dec. 112 / Hex 7010.3 Adress 126 Visning av Bus Adress från Dec. 1 till 127 (Hex 00 till 7F)

10 Simulering - FOUNDATION Fieldbus H110.1 Ej tillåtet Simulering ej tillåten10.2 Tillåtet Simulering tillåten

10 FF konfigurering10.1 Simulering Tillåten Simulering ej tillåten Ej tillåten Simulering tillåten10.2 Profil Link Master Link Master aktiv Basic device Link Master ej aktiv

6. LCD - Menystruktur (forts)

Page 18: NAF-LinkIT...1 NAF-LinkIT Quick Guide Fi 41.85-1(3)GB/SE 08.10 NAF-LinkIT Service manual/Servicemanual Quick Guide Content/Innehållsförteckning: English version: Page 2-10 2 1.1

18

7. Säkerhetskrav för NAF-LinkIT 370991

Teknisk data för explosionssäkert utförande: Se EU-certifi kat och produktspecifi ka-tion.EU-Certifi kat: PTB 00 ATEX 2128 för 370991

Lägesställaren skall installeras och manövreras av kvalifi cerad personal, som är bekant med driftsättning och manövrering av produkten.

Förebygga olyckorDet ansluta instrumentet innehåller rörliga delar, exempelvis återföringsarm som kan orsaka skador. Operatören ska ha rätt instruktioner.

Elektrisk säkerhetInstrumentet överensstämmer med säkerhetsföreskrifterna enligt EN 61010-1 (eller IEC 1010-1, säkerhetsklass III. överlastkategori I). Allt arbete på elektriska delar skall utföras av kvalifi cerad personal, om spänning är anslutet till instrumentet. Instrumentet ska användas för avsett ändamål och anslutas enligt instrumentets kopplingsschema. Nationella applikationsregler för elektrisk utrustning skall följas. Instrumentet ska arbeta med extra låg spänning SELV eller SELV-E. Säkerhetsåt-gärder utförda i instrumentet kan visa sig vara verkningslösa om instrumentet inte handhas enligt instruktion. Gränser avseende spänningsmatning för brandskydd ska följas enligt EN 61010-1, bilaga F (eller IEC 1010-1).

Elektrisk klassning, underhåll av Ex-instrumentFör installation i explosiva miljöer ska alla nationella regler och installationsregler beaktas. Not: Vid reparation eller byte av explosionsskyddad utrustning ska natio-nella regler följas. För underhåll och reparation på ingående delar, använd endast tillverkarens originaldelar.

EMC och CEBeträffande elektromagnetisk kompatibilitet EMC och för CE märkningsidentifi ering, se produktblad. För att säkerställa EMC skydd, ska elektroniklocket skruvas i huset.

Elektriska anslutningarFör installation och drift i explosionsfarliga områden, ska applikationen följa de nationella standarderna. För anslutning till egensäker krets, ska kraven enligt EU-certifi kat användas. Oanvända hål för kabelförskruvningar ska tätas.

Speciella tillämpningar för NAF-LinkIT 370991-xP Profi bus lägesställareOm lägesställaren är ansluten till ytterligare instrument ska FISCO-modellen an-vändas som bas, anslutningskrav enligt PNO Profi bus PA Användare och installa-tionsanvisning (version 2.2). Om detta inte är tillämpligt ska reglerna för certifi erad anslutning enligt PTB-rapport PTH-ThEx-10 tillämpas och följas.

Varning: Notera för tillägg ”Gränslägen”Tillägg ”Gränslägen” 370991-xxxT, U eller V. Fara för skada: Vidrör ej kam under drift.

Varning: Notera för tillägg gränslägen anslutna till högspänning!För lägesställare eller lägesgivare med tillägg gränslägen (370991-xxxV) erfordras ett överströmsskydd avsäkrat med en 2,5A säkring. Gränslägena måste anslutas till en isolerad ingång som tillåter att spänningsförsörjningen avbryts enligt beskriv-ning i EN 61010-1 direktiv i paragraf 6.12.

Page 19: NAF-LinkIT...1 NAF-LinkIT Quick Guide Fi 41.85-1(3)GB/SE 08.10 NAF-LinkIT Service manual/Servicemanual Quick Guide Content/Innehållsförteckning: English version: Page 2-10 2 1.1

19

7. Säkerhetskrav för NAF-LinkIT 370991 (forts)

Varning: Notera för NAF-LinkIT (alla versioner)Programmering via programmeringskontakt kan endast utföras i icke explosiva miljöer, annars blir den inre säkerheten verkningslös. För att undvika skador på Ex-relevanta delar, ska en lämpligt galvaniskt skild prgramadapter användas.

Ytterligare produktinformation är tillgänglig via internet: www.naf.se

Page 20: NAF-LinkIT...1 NAF-LinkIT Quick Guide Fi 41.85-1(3)GB/SE 08.10 NAF-LinkIT Service manual/Servicemanual Quick Guide Content/Innehållsförteckning: English version: Page 2-10 2 1.1

e-mail Website:

VEREENIGINGTel: 011 397 2833Fax: 011 397 4700

DURBANTel: 031 579 2593Fax: 031 579 2562

E-mail: [email protected]: [email protected]