Nada Mohamed Ahmed, MD, MT (ASCP)i. Prior to the development of the EIA/ELISA, the only option for...

20
ELISA Nada Mohamed Ahmed , MD, MT (ASCP)i

Transcript of Nada Mohamed Ahmed, MD, MT (ASCP)i. Prior to the development of the EIA/ELISA, the only option for...

Page 1: Nada Mohamed Ahmed, MD, MT (ASCP)i. Prior to the development of the EIA/ELISA, the only option for conducting an immunoassay was radioimmunoassay, a technique.

ELISA

Nada Mohamed Ahmed ,MD, MT (ASCP)i

Page 2: Nada Mohamed Ahmed, MD, MT (ASCP)i. Prior to the development of the EIA/ELISA, the only option for conducting an immunoassay was radioimmunoassay, a technique.

HISTORY • Prior to the development of the

EIA/ELISA, the only option for conducting an immunoassay was radioimmunoassay, a technique using radioactively-labeled antigens or antibodies.

• Radioimmunoassay was first described in a paper by Rosalyn Sussman Yalow and Solomon Berson published in 1960.

Page 3: Nada Mohamed Ahmed, MD, MT (ASCP)i. Prior to the development of the EIA/ELISA, the only option for conducting an immunoassay was radioimmunoassay, a technique.

Introduction to ELISA• ELISA, or enzyme-linked

immunosorbent assay, is an immunoassay technique involving the reaction of antigen and antibody in vitro. ELISA is a sensitive and specific assay for the detection and quantitation of antigens or antibodies. ELISA tests are usually performed in microwell plates.

• The ELISA test, or the enzyme immunoassay (EIA), was the first screening test commonly employed for HIV. It has a high sensitivity.

Page 4: Nada Mohamed Ahmed, MD, MT (ASCP)i. Prior to the development of the EIA/ELISA, the only option for conducting an immunoassay was radioimmunoassay, a technique.

A 96-WELL MICROTITER PLATE USED FOR ELISA

Page 5: Nada Mohamed Ahmed, MD, MT (ASCP)i. Prior to the development of the EIA/ELISA, the only option for conducting an immunoassay was radioimmunoassay, a technique.

COMPONENTS OF AN ELISA

• Antibody: IgG fraction of serum purified by affinity chromatography

• Enzyme: Horse Radish Peroxidase (HRP) MW 44, 000, glycoprotein with 4 lysine residues

• Substrate: TMB (3,3',5,5', tetramethylbenzidine) The enzyme acts as a catalyst to oxidize substrate in the presence of Hydrogen peroxide to produce a blue color. Reaction stopped with dilute acid to cause complex to turn yellow.

Page 6: Nada Mohamed Ahmed, MD, MT (ASCP)i. Prior to the development of the EIA/ELISA, the only option for conducting an immunoassay was radioimmunoassay, a technique.

Principle of ELISA

• Antibody is immobilized on micro-plate wells

• Competition between in sample and labeled enzyme for antibody binding sites

• The unbound material is washed out • Chromogenic substrate added to

develop color • Resulting color is read in a

spectrophotometer

Page 7: Nada Mohamed Ahmed, MD, MT (ASCP)i. Prior to the development of the EIA/ELISA, the only option for conducting an immunoassay was radioimmunoassay, a technique.
Page 8: Nada Mohamed Ahmed, MD, MT (ASCP)i. Prior to the development of the EIA/ELISA, the only option for conducting an immunoassay was radioimmunoassay, a technique.

Types of ELISA• Direct ELISA• Indirect ELISA• Sandwich ELISA

Page 9: Nada Mohamed Ahmed, MD, MT (ASCP)i. Prior to the development of the EIA/ELISA, the only option for conducting an immunoassay was radioimmunoassay, a technique.

Direct ELISAThe direct ELISA uses the method of directly labeling the antibody itself.

Microwell plates are coated with a sample containing the target antigen, and the binding of labeled antibody is quantitated by a colorimetric, t, or fluorescent end-point.

Page 10: Nada Mohamed Ahmed, MD, MT (ASCP)i. Prior to the development of the EIA/ELISA, the only option for conducting an immunoassay was radioimmunoassay, a technique.

Direct ELISAAdvantages of Direct Detection• Quick methodology since only one antibody is used. • Cross-reactivity of secondary antibody is

eliminated.

Disadvantages of Direct Detection• Immunoreactivity of the primary antibody may be

reduced as a result of labeling. • Labeling of every primary antibody is time-

consuming and expensive. • No flexibility in choice of primary antibody label

from one experiment to another.

Page 11: Nada Mohamed Ahmed, MD, MT (ASCP)i. Prior to the development of the EIA/ELISA, the only option for conducting an immunoassay was radioimmunoassay, a technique.

Indirect ELISA• The indirect ELISA utilizes an

unlabeled primary antibody in conjunction with a labeled secondary antibody. Since the labeled secondary antibody is directed against all antibodies of a given species it can be used with a wide variety of primary antibodiesز

Page 12: Nada Mohamed Ahmed, MD, MT (ASCP)i. Prior to the development of the EIA/ELISA, the only option for conducting an immunoassay was radioimmunoassay, a technique.

Indirect ELISAAdvantages of indirect detection• Wide variety of labeled secondary

antibodies are available commercially. • Immunoreactivity of the primary antibody is

not affected by labeling. • Sensitivity is increased because each

primary antibody contains several epitopes that can be bound by the labeled secondary antibody, allowing for signal amplification.

Page 13: Nada Mohamed Ahmed, MD, MT (ASCP)i. Prior to the development of the EIA/ELISA, the only option for conducting an immunoassay was radioimmunoassay, a technique.

Disadvantages of indirect detection

• Cross-reactivity may occur with the secondary antibody, resulting in nonspecific signal.

• An extra incubation step is required in the procedure.

Page 14: Nada Mohamed Ahmed, MD, MT (ASCP)i. Prior to the development of the EIA/ELISA, the only option for conducting an immunoassay was radioimmunoassay, a technique.

Sandwich ELISA

1. Plate is coated with a capture antibody

2. Sample is added, and any antigen present binds to capture antibody

3. Detecting antibody is added, and binds to antigen

4. Enzyme-linked secondary antibody is added, and binds to detecting antibody

5. Substrate is added, and is converted by enzyme to detectable form.

Page 15: Nada Mohamed Ahmed, MD, MT (ASCP)i. Prior to the development of the EIA/ELISA, the only option for conducting an immunoassay was radioimmunoassay, a technique.
Page 16: Nada Mohamed Ahmed, MD, MT (ASCP)i. Prior to the development of the EIA/ELISA, the only option for conducting an immunoassay was radioimmunoassay, a technique.

ELISA with weak signal • Wash buffer not adequately drained

after every wash step.• Inadequate incubation times.• Detection reagents too dilute. Perform

checkerboard titrations.• Enzyme conjugate defective or

inhibited by contaminant.• Substrate defective or contaminated.• Microwell plates poorly coated.

Page 17: Nada Mohamed Ahmed, MD, MT (ASCP)i. Prior to the development of the EIA/ELISA, the only option for conducting an immunoassay was radioimmunoassay, a technique.

Applications• Screening donated blood for

evidence of viral contamination by – HIV-1 and HIV-2 (presence of anti-HIV

antibodies) – hepatitis C (presence of antibodies) – hepatitis B (testing for both antibodies

and a viral antigen) • Measuring hormone levels – HCG (as a test for pregnancy) – LH (determining the time of ovulation) – TSH, T3 and T4 (for thyroid function)

Page 18: Nada Mohamed Ahmed, MD, MT (ASCP)i. Prior to the development of the EIA/ELISA, the only option for conducting an immunoassay was radioimmunoassay, a technique.

• Detecting infections – sexually-transmitted agents like HIV,

syphilis and chlamydia – hepatitis B and C – Toxoplasma gondii

• Detecting allergens in food and house dust

• Measuring "rheumatoid factors" and other autoantibody in autoimmune diseases like lupus erythematosus

• Measuring toxins in contaminated food

Page 19: Nada Mohamed Ahmed, MD, MT (ASCP)i. Prior to the development of the EIA/ELISA, the only option for conducting an immunoassay was radioimmunoassay, a technique.

Equipment for performing the ELISA test

PipettesIncubator

ELISA reader

Page 20: Nada Mohamed Ahmed, MD, MT (ASCP)i. Prior to the development of the EIA/ELISA, the only option for conducting an immunoassay was radioimmunoassay, a technique.

THANKS