MULTI-POINT DENSITY ARRAY
Transcript of MULTI-POINT DENSITY ARRAY
MULTI-POINT DENSITY ARRAYFIXED-POINT INTERFACE PROFILING MEASUREMENT
Why Multi-PointDENSITY ARRAY?Leadership in Radiation-Based MeasurementOhmart/VEGA is proud to offer the ultimate in fixed-point interface profiling measurements, the DSG Multi-Point Density Array (MDA). Offering high resolution and unparalleled method of measuring interfaces including those with emulsion layers, the DSG MDA is designed to operate in the most difficult of applications including:
• Free Water Knock Out vessels ( FWKO) • Treaters • De-Salters • Low and High Temperature Separators
4 :: DENSITY ARRAY ::
Features & BENEFITSAccuracy and Repeatability Ohmart/VEGA’s MDA system provides accurate and repeatable density information, specific to each horizontal plane.
Continuous Density Output A continuous density output is provided from each individual measurement point providing the operator information on the density of the oil, emulsion and water.
Emulsion Detection As these outputs change on multiple gauges, the movement of the interface and the size of the emulsion layer can be determined.
Low Maintenance The system is low maintenance because it does not contact the process directly (no wetted parts). Thin coatings on the source dry well will have minimal affect on the measurement.
Uninterrupted Operation With multiple measurement points a failure of one detector does not shut down the operation of the vessel.
Flexible Mounting Configuration Internal structures in the vessel, such as electrostatic grids, can alter the mounting configuration, but typically can be accommodated. Additionally, external mounting of the detectors and insertion sources can provide flexibility for future changes in the measurement span.
Extensive Diagnostics The use of Ohmart/VEGA’s OhmView Software program provides extensive diagnostics of each gauge via a connection with the 4 to 20 mADC HART® Protocol signal of each gauge. Alternatively, all gauge diagnostics can be accessed through a single connection with OhmView via a gauge to gauge RS485 connection.
Principles of OPERATIONA continuous density output is provided from each individualmeasurement point providing the operator information on thedensity of the oil, emulsion, and water. As these outputs changeon multiple gauges, the movement of the interface and the sizeof the emulsion layer can be determined.
DEFINED (CLEAR) INTERFACE
INTERFACE WITH EMULSION LAYER
6 :: DENSITY ARRAY ::
System COMPONENTS The MDA System Consists of 3 Components: • Source Holders: containing a source of gamma radiation
• Radiation-based Detectors
• Operator Interface System: displays the detector outputs to indicate the process conditions
Specific selection of these various components is dependent upon each application and the customer’s measurement purpose. Vessel size, shape, wall thicknesses, measurement span of interest, measurement span resolution, ambient and process temperatures, and other application variables will determine the number and specification of the individual components of the system.
The measurement span and resolution determine the number and orientation of the detector array, mounted on the outside of the vessel, which determines the source holder and source requirements (number, size, location, and construction) normally inserted into a dry well on the vessel through a flanged interface between the source holder and the vessel dry well. Dry wells can be straight or curved to meet the needs of the applications.
The customer interface receives the detector outputs, generally multiple 4 to 20 mADC HART Protocol outputs and manipulates the outputs to provide the operators with an indication of the interfaces in the vessel. The Ohmart/VEGA MDA can simply provide multiple outputs to a distributed control system (DCS) for a graphical indication from each gauge or combine the signals as appropriate to provide a measure of the thickness of various interfaces or an overall level indication.
SHLM Series of Source Holders• Insertion type source holder for installation on a process drywell.• Available with a stainless steel cable or solid rod versions• Multiple source configuration available• Shutter lockout (optional)• Able to be used on high pressure or temperature applications
SOURCE HOLDERS
Electronics• The GEN2000® electronics is a modern generation of compact, light weight, and modular electronics utilized by many Ohmart/VEGA level and density detectors.
Cast Aluminum Compact Housing• Light weight and compact• Available with PVC coating for aggressive environments
Modular Electronics• Easy maintenance• Surface mounted component technology for increased reliability
Outputs• 4-20 mADC with HART Protocol communications• Foundation Fieldbus digital protocol
Universal Power Input• Power supply can be connected to an AC or DC input
Configuration• HART Handheld• PC software OhmView 2000
O-ring Seal Design• To prevent moisture infiltration and allow 360 degrees orientation, the
housing incorporates o-ring seals at the threaded connections
8 :: DENSITY ARRAY ::
System COMPONENTScontinued
RADIATION-BASED DETECTORS
OhmView 2000 SoftwareUser friendly English prompt softwaretool for configuration, maintenance,trending and diagnostics of theGEN2000 series gauges.
OPERATOR INTERFACE SYSTEM
PLC-Based InterfaceAs an option Ohmart/VEGA can provide aprogrammable logic controller (PLC) to either locally or remotely display the detector information.The remotely mounted PLC can also be configured toprovide the measurement outputs back to a DCSsystem via a single ModBus or ether digital signal.
• The PLC display will display individual densities in each specific zone of measurement.• The target densities for oil and water can also be displayed.• Relay outputs can provide alarming capabilities.• A combination of point density outputs can indicate overall
vessel levels.• The PLC system can be mounted remotely or locally• If mounted locally, at the separator, it allows all density
measurements to be transmitted via a single ModBus or other digital signal back to the customers control system, thus reducing wiring requirements.
10 :: DENSITY ARRAY ::
Training &SERVICE
• 24-hour emergency service phone support• Radiation survey meter calibration• Product training and system operation• Radiation safety school certification• Wipe test and wipe test analysis• Service, maintenance, and disposal of source material• Start up and commissioning
Ohmart/VEGA is able to meet all of your radiation service and training needs. With state of the art classroom facilities, service personnel located world wide, and a full production and service facility, Ohmart/VEGA is always ready to provide the following:
Other Ohmart/VEGA Interface
MeasurementSYSTEMS
CONTINUOUS RADAR LEVELThe VEGAFLEX 67 is a guided microwave sensor designed tomeasure the level of the interface between two liquids. Theprimary output is the level of the lower liquid, but the overall level information is available by using additional signalconditioning instruments.
NUCLEAR INTERFACE MEASUREMENT The SmartScan Profiler uses an integral source that iscontained within the “leg” of the unit. The source is raisedand lowered by a motor-driven tape to provide full vessel scanning.
CONTINUOUS LEVEL The FiberFlex® is the industry’s only flexible radiation level detector and features Ohmart/VEGA’s GEN2000 family of electronics. With its patented fiber optic scintillator bundle, the FiberFlex has significant advantages over both solid scintillators and traditional ion chamber detectors.