MTS-MPM - Renogy...GB 50009 – 2012 (7.1.1) (Snow Rating) 18 GB50009 – 2012 (Load Structure for...

18
1 MTS-MPM Multi-Panel Mounting System 2775 E Philadelphia St, Ontario, CA 91761 1-800-330-8678

Transcript of MTS-MPM - Renogy...GB 50009 – 2012 (7.1.1) (Snow Rating) 18 GB50009 – 2012 (Load Structure for...

Page 1: MTS-MPM - Renogy...GB 50009 – 2012 (7.1.1) (Snow Rating) 18 GB50009 – 2012 (Load Structure for Building Structures GB50011- 2010 (Code for Seismic Design of Buildings) GB50017

1

MTS-MPM

Multi-Panel Mounting System

2775 E Philadelphia St, Ontario, CA 91761 1-800-330-8678

Page 2: MTS-MPM - Renogy...GB 50009 – 2012 (7.1.1) (Snow Rating) 18 GB50009 – 2012 (Load Structure for Building Structures GB50011- 2010 (Code for Seismic Design of Buildings) GB50017

2

Important Safety Instructions Please save these instructions.

This manual contains important safety, installation, and operating instructions for the hardware

system. The following symbols are used throughout the manual to indicate potentially dangerous

conditions or important safety information.

WARNING: Indicates a potentially dangerous condition. Use extreme caution when

performing this task.

CAUTION: Indicates a critical procedure for safe and proper operation of the system. NOTE: Indicates a procedure or function that is important to the safe and proper operation

of the system.

General Safety Information

• Read all of the instructions and cautions in the manual before beginning the installation.

• Do NOT attach solar panel to multi-panel pole mount until mount is securely fit, and pole base has been secured.

• Chance to strip nuts and bolts exists.

• Multiple people for installation is suggested.

• Do NOT substitute parts from other manufacture ring sources, doing so may void the warranty and/or result in an unstable system

• This system is NOT possessing any compliance with residential structural codes and should not be used in place of a system that is, if so required by local regulations

Installer Responsibilities

• Installation compliance with any applicable codes which are enforced at the installation

site.

• Installation compliance and compatibility with all system components and the environment

including but not limited to roofing, system components, etc.

• Verification that all project information is accurate

• Ensure proper array structure grounding, including each module frame and the mounting

pole. Failure may result in damage to your equipment. Do NOT rely on mounting pipe to

act as grounding rod! It is not a reliable substitute.

Page 3: MTS-MPM - Renogy...GB 50009 – 2012 (7.1.1) (Snow Rating) 18 GB50009 – 2012 (Load Structure for Building Structures GB50011- 2010 (Code for Seismic Design of Buildings) GB50017

3

WARNING: these instructions are intended to be used by individuals with sufficient

technical skills for the task. Knowledge and use of hand tools, measuring devices, and

torque equipment is also required

WARNING: Electrocution Hazard! Check for clearance to overhead power lines before

bringing any installation.

WARNING: Watch your hands and fingers! We make every effort to remove sharp edges

from the galvanized products. However, we still recommend installers wear gloves

when handling these mounts in order to avoid the sharp edges.

WARNING: The mount is heavy! Depending on the modules you are using, the weight

will only increase. Therefore, it is recommended to have the aid of another person

and/or lifting devices that can help install this safely. Failure to observe this warning

can hurt or kill you.

Page 4: MTS-MPM - Renogy...GB 50009 – 2012 (7.1.1) (Snow Rating) 18 GB50009 – 2012 (Load Structure for Building Structures GB50011- 2010 (Code for Seismic Design of Buildings) GB50017

4

Table of Contents

General Information ......................................................................................................................................... 5

Material List .......................................................................................................................................................... 5

Installation ............................................................................................................................................................. 9

Foundation .................................................................................................................................................. 10

Compatibility with Renogy Panels ..................................................................................................... 11

1- Install Base Column on the Foundation ...................................................................................... 12

2- Install Connector on Base Column ................................................................................................ 12

3- Install Main Girder and Angle Adjustment Connector .......................................................... 13

4- Install Cross Beams on Main Girder ............................................................................................. 14

5- Install Solar Panels with End Clamps and Mid Clamps ........................................................ 15

6- Check All Parts to Ensure Safety.................................................................................................... 17

Check all screws and clamps to make sure all parts are securely installed. ...................... 17

Maintenance ...................................................................................................................................................... 17

Technical Specifications ........................................................................................................................... 17

Compatibility ..................................................................................................................................................... 18

Page 5: MTS-MPM - Renogy...GB 50009 – 2012 (7.1.1) (Snow Rating) 18 GB50009 – 2012 (Load Structure for Building Structures GB50011- 2010 (Code for Seismic Design of Buildings) GB50017

5

General Information

The Renogy MTS-MPM is designed for off-grid applications when mounting on a roof is not ideal.

Composed of high strength steel and corrosion resistant welded components, the MTS-MPM can

support up to 400 Watts of power. The system comes complete with all fasteners to adhere panels

to the mounting surface. This system makes the installation solar systems, easy, affordable, and

quick.

Key Features

• Galvanized Steel and Anodized Aluminum Alloy construction

• High-tensile strength and corrosion free fasteners

• Precision hole positioning and alignment

• Compatible with multiple Renogy PV sizes—(4) 100W Mono, (2) 160W Mono, (1) 270W

Poly, (1) 300W Mono

• Secures most 100W-350W PV modules

• Mount up to 400W on a single pole

• Standard design can withstand up to 75mph wind

Material List

Image Component Size / in Qty. Material

Base Column

4.3(diameter)x

59.1

1 Q235

Steel

Page 6: MTS-MPM - Renogy...GB 50009 – 2012 (7.1.1) (Snow Rating) 18 GB50009 – 2012 (Load Structure for Building Structures GB50011- 2010 (Code for Seismic Design of Buildings) GB50017

6

Connector 4.5(diameter)x

5.91 1

Q235

Steel

Angle Adjustment

Connector 1.2x1.2x12.8 1

Q235

Steel

Main Girder

2.4x2.4x78.8 1

Q235

Steel

Cross Beam

1.6x1.6x63.0

4

Q235

Steel

End Clamp Piece 1.5x1.6x1.6 8+(2)

spare*

H35

Aluminum

Page 7: MTS-MPM - Renogy...GB 50009 – 2012 (7.1.1) (Snow Rating) 18 GB50009 – 2012 (Load Structure for Building Structures GB50011- 2010 (Code for Seismic Design of Buildings) GB50017

7

Mid Clamp Piece 1.4x1.0x2.0 4+(1)

spare*

H40

Aluminum

Strut Channel Nut with Plastic Wing

2.0x1.3x0.7 12+(2)

spare*

Plastic

and steel

Positioning Plate for Base Column

7.9x7.9x0.3 1 Q235

steel

U-Bolt for Base Installation

7.1x6.0x0.4(di

ameter) 2

Q235

Steel

Socket Head Screw

M8 x 50 14+(2) spare*

S304

Stainless

Steel

Socket Head Screw

M8 x 20 2+(1)

spare*

S304

Stainless

Steel

Page 8: MTS-MPM - Renogy...GB 50009 – 2012 (7.1.1) (Snow Rating) 18 GB50009 – 2012 (Load Structure for Building Structures GB50011- 2010 (Code for Seismic Design of Buildings) GB50017

8

Socket Head Screw

M10 x 20 8+(2)

spare*

S304

Stainless

Steel

Socket Head Screw

M12 x 100 1+(1)

spare*

S304

Stainless

Steel

Hex Nut M8 2+(2)

spare*

S304

Stainless

Steel

Hex Nut M10 12+(2)

spare*

S304

Stainless

Steel

Hex Nut M12 1+(1)

spare*

S304

Stainless

Steel

Split Lock Washer M8 10+(2)

spare*

S304

Stainless

Steel

Split Lock Washer M10 8+(2)

spare*

S304

Stainless

Steel

Page 9: MTS-MPM - Renogy...GB 50009 – 2012 (7.1.1) (Snow Rating) 18 GB50009 – 2012 (Load Structure for Building Structures GB50011- 2010 (Code for Seismic Design of Buildings) GB50017

9

Split Lock Washer M12 1+(1)

spare*

S304

Stainless

Steel

Flat Washer M8 10+(2)

spare*

S304

Stainless

Steel

Flat Washer M10 8+(2)

spare*

S304

Stainless

Steel

Flat Washer M12 1+(1)

spare*

S304

Stainless

Steel

*Spare parts serve as safety margins for installation, spare parts quantity is not guaranteed.

Installation

Renogy assumes no responsibility for your foundation installation. Consult a local

professional for proper installation.

Recommended tools to have before installation (Not provided):

• Standard Wrench Set

• Standard Socket Set

• Allen Wrenches

• Level

• Tape Measure

• Screwdrivers

The above tools and equipment are highly recommended to have available to assist

with installation but are in no way a comprehensive list of tools. Installers feel free to

substitute comparable equipment where appropriate.

Page 10: MTS-MPM - Renogy...GB 50009 – 2012 (7.1.1) (Snow Rating) 18 GB50009 – 2012 (Load Structure for Building Structures GB50011- 2010 (Code for Seismic Design of Buildings) GB50017

10

Foundation

WARNING! Windy conditions can exert extreme forces on the PV array, foundation, and mounting mast of your array.

WARNING! Keep hands clear of pinch points!

NOTE: Choose an optimum solar location that is free from obstructions such as trees and

buildings.

The recommend installation method involves using the provided 2 pieces of U-Bolt, positioning

plate with a cement foundation that users must create. The cement foundation recommended is

a 20” x 20” concrete block square with the positioning plate on top and U-bolt inside. The

foundation may vary depending on soil and location. It is recommended, and in some locations,

required, to seek the advice and or approval of a licensed Professional Engineer familiar with

your local codes and requirements prior to construction.

Page 11: MTS-MPM - Renogy...GB 50009 – 2012 (7.1.1) (Snow Rating) 18 GB50009 – 2012 (Load Structure for Building Structures GB50011- 2010 (Code for Seismic Design of Buildings) GB50017

11

Compatibility with Renogy Panels NOTE: Depending on the user, each multi-panel mount will be optimized for certain PV

module(s). In terms of Renogy arrays, the following are recommended to be affixed:

4 x 100W Mono

4 x 100W Poly

1 x 270W to 300W

NOTE: The provided end clamps are only compatible with 100W-150W panels. When using 270W-300W panels the proper end clamps must be purchased.

Page 12: MTS-MPM - Renogy...GB 50009 – 2012 (7.1.1) (Snow Rating) 18 GB50009 – 2012 (Load Structure for Building Structures GB50011- 2010 (Code for Seismic Design of Buildings) GB50017

12

1- Install Base Column on the Foundation

WARNING! The mount is heavy! Depending on the modules you are using, the weight

will only increase. Therefore, it is recommended to have the aid of another person

and/or lifting devices that can help install this safely. Failure to observe this warning

can hurt or kill you.

WARNING! Keep hands clear of pinch points!

After placing the positioning plate on top and U-blots inside the concrete block, the foundation is now complete. The next step is to place the base column on top of the positioning plate. Use 4 pieces of M10 hex nut to tighten the base column to the U-bolts.

2- Install Connector on Base Column

WARNING! Keep hands clear of pinch points!

Attach the connector to the top of base column with 2 pieces of M8x20 socket head screw and M8 hex nut.

Page 13: MTS-MPM - Renogy...GB 50009 – 2012 (7.1.1) (Snow Rating) 18 GB50009 – 2012 (Load Structure for Building Structures GB50011- 2010 (Code for Seismic Design of Buildings) GB50017

13

3- Install Main Girder and Angle Adjustment Connector

WARNING! Keep hands clear of pinch points!

Attach the main girder and angle adjustment connector to the connector. Please follow the next 3 steps for this part of installation.

Page 14: MTS-MPM - Renogy...GB 50009 – 2012 (7.1.1) (Snow Rating) 18 GB50009 – 2012 (Load Structure for Building Structures GB50011- 2010 (Code for Seismic Design of Buildings) GB50017

14

Step 1: Attach the angle adjustment connector to the connector with a M8x50 socket head screw, a M8 split lock washer, a M8 flat washer and a M8 hex nut. Step 2: Attach the main girder to the connector with a M12x100 socket head screw, a M12 split lock washer, a M12 flat washer and a M12 hex nut. Step 3: Choose the desired angle from 10 to 50 degrees for the main girder by choosing suitable installation hole. Attach the angel adjustment connector to the main girder with a M8x50 socket head screw, a M12 split lock washer, a M8 flat washer and a M8 hex nut.

4- Install Cross Beams on Main Girder

WARNING! Keep hands clear of pinch points!

Attach cross beam to the top of main girder with 2 pieces of M10x20 socket head screw, M10 split lock washer, M10 flat washer and M 12 hex nut. Repeat to install all 4 cross beams.

Page 15: MTS-MPM - Renogy...GB 50009 – 2012 (7.1.1) (Snow Rating) 18 GB50009 – 2012 (Load Structure for Building Structures GB50011- 2010 (Code for Seismic Design of Buildings) GB50017

15

5- Install Solar Panels with End Clamps and Mid Clamps

WARNING! Keep hands clear of pinch points!

Step 1: Push the strut channel nut with plastic wing into the cross beam from side. Then turn the plastic wing 90 degrees to align with the cross beam. Step 2: Put solar panel in the desired position on top of the cross beam. Step 3: Put end clamp and mid clamp on top of strut channel nut, fasten with a M8x50 socket head screw, a M8 split lock washer, a M8 flat washer Step 4: Repeat step 1 to 3 for all end clamps and mid clamps until all panels are securely installed

Page 16: MTS-MPM - Renogy...GB 50009 – 2012 (7.1.1) (Snow Rating) 18 GB50009 – 2012 (Load Structure for Building Structures GB50011- 2010 (Code for Seismic Design of Buildings) GB50017

16

Page 17: MTS-MPM - Renogy...GB 50009 – 2012 (7.1.1) (Snow Rating) 18 GB50009 – 2012 (Load Structure for Building Structures GB50011- 2010 (Code for Seismic Design of Buildings) GB50017

17

6- Check All Parts to Ensure Safety Check all screws and clamps to make sure all parts are securely installed.

Maintenance You should be inspecting your multi-panel mount once per year. While inspecting, make sure of the following:

1. Ensure hardware is tight, tighten if need be 2. Check all wiring connections for tightness and water proof integrity 3. Check for any damage 4. Inspect welds for any visible cracking or other signs of fatigue 5. Check the foundation for any signs of damage or cracking

Technical Specifications

Pole Height 59.1 in

Array Height 62.6 to 74.5 in

Mounting Method U-bolt in concrete foundation (U-bolt provided)

Tilt Angles 10 to 50°

Maximum Wind Speed 72 mph

Max Snow Pressure 23, 940 psf

Gross Weight 165 lb

International Compliant Standards

GB 50009 – 2012 (Wind Rating) GB 50009 – 2012 (7.1.1) (Snow Rating)

Page 18: MTS-MPM - Renogy...GB 50009 – 2012 (7.1.1) (Snow Rating) 18 GB50009 – 2012 (Load Structure for Building Structures GB50011- 2010 (Code for Seismic Design of Buildings) GB50017

18

GB50009 – 2012 (Load Structure for Building Structures GB50011- 2010 (Code for Seismic Design of Buildings) GB50017 – 2003 (Code for Design of Steel Structures) GB50018 – 2002 (Cold – formed thin – Walled Steel Structure Technical Specification GB50429 – 2007 (Code for Design of Aluminum Alloy Structures) GB50797 – 2012 (Design Code for Photovoltaic Power Station)

Warranty 1 year

Compatibility

RENOGY Solar Module Compatibility* RNG-10D-SS INCOMPATIBLE

RNG-20D-SS INCOMPATIBLE

RNG-30D-SS INCOMPATIBLE

RNG-50D-SS INCOMPATIBLE

RNG-80D-SS COMPATIBLE

RNG-100D COMPATIBLE

RNG-100D-SS COMPATIBLE

RNG-100D-SSP COMPATIBLE

RNG-100D-R COMPATIBLE

RNG-100MB COMPATIBLE

RNG-160D-SS COMPATIBLE

RNG-300D COMPATIBLE

RNG-50P INCOMPATIBLE

RNG-100P COMPATIBLE

RNG-270P COMPATIBLE

* Larger panel may need suitable clamps for installation, which are not provided with product