MPU Replacement Chassis - Honeywell · Honeywell Proprietary Honeywell.com 3 POV-221-110.01 MPU...
Transcript of MPU Replacement Chassis - Honeywell · Honeywell Proprietary Honeywell.com 3 POV-221-110.01 MPU...
![Page 1: MPU Replacement Chassis - Honeywell · Honeywell Proprietary Honeywell.com 3 POV-221-110.01 MPU Replacement Chassis – October 2011 Process Solutions NEW MPU Replacement Chassis](https://reader031.fdocuments.in/reader031/viewer/2022012318/5c3397d609d3f2fd288b49b0/html5/thumbnails/1.jpg)
MPU Replacement Chassis
October 2011
![Page 2: MPU Replacement Chassis - Honeywell · Honeywell Proprietary Honeywell.com 3 POV-221-110.01 MPU Replacement Chassis – October 2011 Process Solutions NEW MPU Replacement Chassis](https://reader031.fdocuments.in/reader031/viewer/2022012318/5c3397d609d3f2fd288b49b0/html5/thumbnails/2.jpg)
Honeywell Proprietary
Honeywell.com
2
POV-221-110.01 MPU Replacement Chassis – October 2011
Process Solutions
Legacy Measurex MPU Interface
• Measurex MPU Chassis from the
early 1980’s reached end-of-life
long ago.
– MPU was Measurex interface for
CD actuators
• ThermaTrol, AquaTrol, CalTrol,
SteamTrol
– MPU withdrawn from sale in 1992
• Replaced by Profile Managers with
GE 90/70 PLC
• Whatever parts still available
today are offered only under the
'repair exchange' procedure or a
'level 1 down' with return
afterwards.
![Page 3: MPU Replacement Chassis - Honeywell · Honeywell Proprietary Honeywell.com 3 POV-221-110.01 MPU Replacement Chassis – October 2011 Process Solutions NEW MPU Replacement Chassis](https://reader031.fdocuments.in/reader031/viewer/2022012318/5c3397d609d3f2fd288b49b0/html5/thumbnails/3.jpg)
Honeywell Proprietary
Honeywell.com
3
POV-221-110.01 MPU Replacement Chassis – October 2011
Process Solutions
NEW MPU Replacement Chassis
• Digital Outputs ONLY:
– Duty cycle (ThermaTrol, CalTrol, Calcoil) or 4-bit parallel (AquaTrol)
• Standard I/O PCB: switch selectable duty cycle or 4-bit parallel
• 200-100 serial links ONLY (RS232 or FSK)
• Status feedback inputs NOT supported
• ScaniValve NOT supported
• CWS double-precision protocols NOT supported
![Page 4: MPU Replacement Chassis - Honeywell · Honeywell Proprietary Honeywell.com 3 POV-221-110.01 MPU Replacement Chassis – October 2011 Process Solutions NEW MPU Replacement Chassis](https://reader031.fdocuments.in/reader031/viewer/2022012318/5c3397d609d3f2fd288b49b0/html5/thumbnails/4.jpg)
Honeywell Proprietary
Honeywell.com
4
POV-221-110.01 MPU Replacement Chassis – October 2011
Process Solutions
Scope - MPU Replacement Kit
• Drop-in replacement for the MPU Chassis assembly
– Ref: Models 2573 and 2575 interface sub-systems in Production
Release documents
– Used for ThermaTrol, CalTrol, and AquaTrol actuators.
• The kit replaces the complete MPU chassis and all PCBs
– Ribbon-cable connections and functions all compatible with the
original chassis.
– All existing power-switching electronics and terminations to the
actuators are to be retained and remain unchanged.
– Replaced components include
• MPU Chassis / Power Supply (08343800),
• MPU Processor (05365800)
• PAV interface boards (05287000).
![Page 5: MPU Replacement Chassis - Honeywell · Honeywell Proprietary Honeywell.com 3 POV-221-110.01 MPU Replacement Chassis – October 2011 Process Solutions NEW MPU Replacement Chassis](https://reader031.fdocuments.in/reader031/viewer/2022012318/5c3397d609d3f2fd288b49b0/html5/thumbnails/5.jpg)
Honeywell Proprietary
Honeywell.com
5
POV-221-110.01 MPU Replacement Chassis – October 2011
Process Solutions
Success Story – Augusta Newsprint
From John Anderson (Field Service Specialist) 10/10/2011:
• The new and improved MPU upgrade kits dropped right
in. There is one card (processor) that requires some simple
configuration (a jumper and a switch). On the old MPU’s, the
Aquatrol, Thermatrol, and Caliper controls have unique processor
cards/proms. The MPU upgrade kits have cards are
interchangeable between other MPU upgrade kits, reducing the
amount of spares required.
• ….Things went great. We haven’t had any issues with them so
far – over a year.
![Page 6: MPU Replacement Chassis - Honeywell · Honeywell Proprietary Honeywell.com 3 POV-221-110.01 MPU Replacement Chassis – October 2011 Process Solutions NEW MPU Replacement Chassis](https://reader031.fdocuments.in/reader031/viewer/2022012318/5c3397d609d3f2fd288b49b0/html5/thumbnails/6.jpg)
Honeywell Proprietary
Honeywell.com
6
POV-221-110.01 MPU Replacement Chassis – October 2011
Process Solutions
Scope - continued
Old MPU chassis (left) is replaced by the drop-in
replacement kit (right)
![Page 7: MPU Replacement Chassis - Honeywell · Honeywell Proprietary Honeywell.com 3 POV-221-110.01 MPU Replacement Chassis – October 2011 Process Solutions NEW MPU Replacement Chassis](https://reader031.fdocuments.in/reader031/viewer/2022012318/5c3397d609d3f2fd288b49b0/html5/thumbnails/7.jpg)
Honeywell Proprietary
Honeywell.com
7
POV-221-110.01 MPU Replacement Chassis – October 2011
Process Solutions
Models 8891 & 8892
Items to order: Configuration & Quantities:
MPU Replacement Kit Chassis with Power
Supply & Processor, #09889100
Customer Sell Price: US$ $13,879.00 per set
Delivery: unforecasted lead time 22 weeks
Notes: (a) order from Vancouver ONLY. Limited
quantities on hand for prompt shipment.
Check before committing. (b) K&E Pricing
requires return of the old equipment to
Honeywell
Order qty 1 per actuator “beam” (ThermaTrol,
CalTrol, or AquaTrol)
Input voltage: 115 VAC, 50 / 60 Hz
Serial Link: RS232 or FSK
Protocol: 200-100 with 6-bit setpoints
MPU Replacement Kit Output PCB,
#09889200
Customer Sell Price: US$ $2891.00 each
Delivery: unforecasted lead time 22 weeks
* Notes: same as above
For Duty Cycle outputs to ThermaTrol, CalTrol,
Calcoil, order 1 per 32 zones (max 4 PCB)
Max number of zones per chassis: 128
Duty Cycle: 8-second time base with 125-
millisecond resolution (6-bit setpoint)
For 4-Bit Parallel outputs to AquaTrol;
order 1 per 8 zones (max 9 PCB)
Max number of zones per chassis:72
![Page 8: MPU Replacement Chassis - Honeywell · Honeywell Proprietary Honeywell.com 3 POV-221-110.01 MPU Replacement Chassis – October 2011 Process Solutions NEW MPU Replacement Chassis](https://reader031.fdocuments.in/reader031/viewer/2022012318/5c3397d609d3f2fd288b49b0/html5/thumbnails/8.jpg)
Honeywell Proprietary
Honeywell.com
8
POV-221-110.01 MPU Replacement Chassis – October 2011
Process Solutions
BOM Breakdown
• Model 8891: MPU Replacement Kit Chassis with Power Supply &
Processor – List Price $13,879.00 (2011 SPM)
– Transfer Price $6999.00 (2011 SPM) – order as 09889100 includes
• Processor Card – Qty 1 Part No. : 6542800045
• Power supply module – Qty 1 Part No. : 6543140089
• Rack complete with back-plane – Qty 1 Part No. : 6543060055
• Installation Guide – Qty 1 Part No.: 6510020266
• Model 8892: MPU Replacement Kit Output PCB – List Price List $2891.00 USD (2011 SPM)
– Transfer Price: $1467.00 (2011 SPM)
– order as 09889200 includes • Digital output Card – Qty 1 Part No. : 6543140090
![Page 9: MPU Replacement Chassis - Honeywell · Honeywell Proprietary Honeywell.com 3 POV-221-110.01 MPU Replacement Chassis – October 2011 Process Solutions NEW MPU Replacement Chassis](https://reader031.fdocuments.in/reader031/viewer/2022012318/5c3397d609d3f2fd288b49b0/html5/thumbnails/9.jpg)
Honeywell Proprietary
Honeywell.com
9
POV-221-110.01 MPU Replacement Chassis – October 2011
Process Solutions
MPU Replacement Chassis w/ 4 I/O PCB
• 1 x 8891 with 4 x 8892 I/O PCB’s, suitable for…
– 128-Zone ThermaTrol or CalTrol (duty cycle) OR
– 32-Zone AquaTrol (4-bit parallel)
![Page 10: MPU Replacement Chassis - Honeywell · Honeywell Proprietary Honeywell.com 3 POV-221-110.01 MPU Replacement Chassis – October 2011 Process Solutions NEW MPU Replacement Chassis](https://reader031.fdocuments.in/reader031/viewer/2022012318/5c3397d609d3f2fd288b49b0/html5/thumbnails/10.jpg)
Honeywell Proprietary
Honeywell.com
10
POV-221-110.01 MPU Replacement Chassis – October 2011
Process Solutions
MPU Replacement Chassis w/ 9 I/O PCB
• 1 x 8891 with 9 x 8892 I/O PCB’s suitable for…
– 72-Zone AquaTrol (4-bit parallel)
![Page 11: MPU Replacement Chassis - Honeywell · Honeywell Proprietary Honeywell.com 3 POV-221-110.01 MPU Replacement Chassis – October 2011 Process Solutions NEW MPU Replacement Chassis](https://reader031.fdocuments.in/reader031/viewer/2022012318/5c3397d609d3f2fd288b49b0/html5/thumbnails/11.jpg)
Honeywell Proprietary
Honeywell.com
11
POV-221-110.01 MPU Replacement Chassis – October 2011
Process Solutions
Product Positioning
• Intended as a service K&E
• Low-cost way to avoid downtime & frustration due to lack of
replacement parts for the MPU chassis
– Literally minutes to install; ribbon cable compatible with MPU
– No software changes; same 200-100 link
• Preserves customer investment in legacy CD actuators without
demanding a technology upgrade
– 200-100 serial link only; LAN communication not supported
– A safe investment regardless of subsequent QCS upgrades
• Experion MX and Da Vinci speak 200-100 protocol
• Technology upgrades should consider actuator replacement, or
at least a new Profile Manager for LAN connectivity
![Page 12: MPU Replacement Chassis - Honeywell · Honeywell Proprietary Honeywell.com 3 POV-221-110.01 MPU Replacement Chassis – October 2011 Process Solutions NEW MPU Replacement Chassis](https://reader031.fdocuments.in/reader031/viewer/2022012318/5c3397d609d3f2fd288b49b0/html5/thumbnails/12.jpg)
Honeywell Proprietary
Honeywell.com
12
POV-221-110.01 MPU Replacement Chassis – October 2011
Process Solutions
Product Positioning
• Field proven: Trial units have been in field operation since
November 2010 without problem.
• MPU Replacement Kit must be ordered from Vancouver Service
Center.
• Limited number of kits on the shelf as of June 2011, and
available for prompt shipment. Check before making any
commitments
• Unforecasted lead time is 22 weeks
• Forecasted demand not yet established, so your inputs &
forecasts are needed to plan future inventory for fast deliveries.
• K&E Pricing requires return of the old equipment to Honeywell
![Page 13: MPU Replacement Chassis - Honeywell · Honeywell Proprietary Honeywell.com 3 POV-221-110.01 MPU Replacement Chassis – October 2011 Process Solutions NEW MPU Replacement Chassis](https://reader031.fdocuments.in/reader031/viewer/2022012318/5c3397d609d3f2fd288b49b0/html5/thumbnails/13.jpg)
Honeywell Proprietary
Honeywell.com
13
POV-221-110.01 MPU Replacement Chassis – October 2011
Process Solutions
Legacy Measurex Actuators & Interfaces
• ThermaTrol I or II – End of Life
– Recommend replacing the actuator with AutoSlice CDW, otherwise:
– If UNITEC interface, replace with HC900 based Profile Manager.
– If MPU, order MPU Replacement Chassis OR new Profile Manager
with duty-cycle interface
• AquaTrol – Still current
– Current product employs similar technology (different solenoids)
– If UNITEC interface, replace with HC900 based Profile Manager.
– If MPU, order MPU Replacement Chassis OR new Profile Manager
with 4-bit parallel outputs to solenoids.
• CalTrol I or II – End of Life
– Recommend replacing with Calcoil, otherwise:
– If UNITEC interface, replace with HC900 based Profile Manager.
– If MPU, order MPU Replacement Chassis OR new Profile Manager
with duty-cycle interface
![Page 14: MPU Replacement Chassis - Honeywell · Honeywell Proprietary Honeywell.com 3 POV-221-110.01 MPU Replacement Chassis – October 2011 Process Solutions NEW MPU Replacement Chassis](https://reader031.fdocuments.in/reader031/viewer/2022012318/5c3397d609d3f2fd288b49b0/html5/thumbnails/14.jpg)
Honeywell Proprietary
Honeywell.com
14
POV-221-110.01 MPU Replacement Chassis – October 2011
Process Solutions
Legacy Measurex Steambox & Interface
• SteamTrol – End of Life
– Very limited parts support; recommend replacement with Devronizer
– Note: XP10 steam actuator upgrade NOT available for SteamTrol
• ScaniValve interface - End of Life
– Unsupported
– Replace ScaniValve interface with IDP II (CDWeb)
– IDP for SteamTrol must be set up for 3-15 psi (not 6-30 psi)
• ODX, RTU Modbus, Modbus TCP, and OPC are currently supported
protocols.
• 200-100, SCL, or ABB Microset serial protocols are not supported by
CDWeb systems.
• Beware: HP or ET systems with only 200-100 links cannot use
IDP. Yet another reason to upgrade now.
![Page 15: MPU Replacement Chassis - Honeywell · Honeywell Proprietary Honeywell.com 3 POV-221-110.01 MPU Replacement Chassis – October 2011 Process Solutions NEW MPU Replacement Chassis](https://reader031.fdocuments.in/reader031/viewer/2022012318/5c3397d609d3f2fd288b49b0/html5/thumbnails/15.jpg)
Honeywell Proprietary
Honeywell.com
15
POV-221-110.01 MPU Replacement Chassis – October 2011
Process Solutions
New Profile Manager - Duty Cycle I/O
• New Duty Cycle I/O systems use HC900 in Profile Manager type
enclosure.
– Used only for legacy actuators (no new actuators use duty cycle)
– Modbus TCP protocol for direct connection to Experion MX, Da Vinci.
– ODX and OPC protocols will add Industrial PC
– Do not call it “CDWeb”. It is not.
• Keep existing power electronics in all cases.
– ThermaTrol I or II
– CalTrol I or II
– Calcoil 4000 (A or D)
• Note: new interface is NOT offered for Calcoil 2000, Impact
ThermaJet, or ABB ThermoProfiler, etc. These are all obsolete,
unsupported, and difficult to repair. Better to replace.
![Page 16: MPU Replacement Chassis - Honeywell · Honeywell Proprietary Honeywell.com 3 POV-221-110.01 MPU Replacement Chassis – October 2011 Process Solutions NEW MPU Replacement Chassis](https://reader031.fdocuments.in/reader031/viewer/2022012318/5c3397d609d3f2fd288b49b0/html5/thumbnails/16.jpg)
Honeywell Proprietary
Honeywell.com
16
POV-221-110.01 MPU Replacement Chassis – October 2011
Process Solutions
New Profile Manager - Parallel I/O
• New AquaTrol systems use HC900 in Profile Manager type
enclosure.
– 4 contact outputs per zone to drive solenoid valves
– Modbus TCP protocol for direct connection to Experion MX, Da Vinci.
– ODX and OPC protocols will add Industrial PC
– Do not call it “CDWeb”. It is not.
• For legacy AquaTrols, same HC900 is available. Please confirm
solenoid voltage on inquiries
– 24 VDC solenoids [same as current systems]
– 24 VAC solenoids [legacy Measurex systems]
– 48 VDC solenoids [legacy Devron systems]
• For legacy AquaTrols, please ensure all tech bulletins have been
applied
![Page 17: MPU Replacement Chassis - Honeywell · Honeywell Proprietary Honeywell.com 3 POV-221-110.01 MPU Replacement Chassis – October 2011 Process Solutions NEW MPU Replacement Chassis](https://reader031.fdocuments.in/reader031/viewer/2022012318/5c3397d609d3f2fd288b49b0/html5/thumbnails/17.jpg)
Honeywell Proprietary
Honeywell.com
17
POV-221-110.01 MPU Replacement Chassis – October 2011
Process Solutions
QCS to Actuator Links, FYI
• Experion MX and Da Vinci support:
– OPC, ODX, LON, Modbus TCP (to current actuators & interface)
– 200-100, SCL, Modbus RTU, ABB Microset (to legacy actuators &
interface)
• New Honeywell actuators support links to foreign / legacy QCS
using:
– OPC, ODX, Modbus TCP
– Modbus RTU
• New Honeywell actuators do NOT support these old serial
protocols:
– SCL
– 200-100
– ABB Microset
![Page 18: MPU Replacement Chassis - Honeywell · Honeywell Proprietary Honeywell.com 3 POV-221-110.01 MPU Replacement Chassis – October 2011 Process Solutions NEW MPU Replacement Chassis](https://reader031.fdocuments.in/reader031/viewer/2022012318/5c3397d609d3f2fd288b49b0/html5/thumbnails/18.jpg)
Honeywell Proprietary
Honeywell.com
18
POV-221-110.01 MPU Replacement Chassis – October 2011
Process Solutions
Questions?
• Contact Mark Bonner / Michelle Wardas / Jan McDonald for
Pricing Inquiries
• Contact Arash Dowlati, Jonathan Crawford, or Tom Steele with
technical questions
• Contact Jack Rumel for CD sales and application support.