MPC-Sample-System 1 10 MPC Sample System 6/17/04 © 2004 Sw agelok C om pany. Sw agelok confidential.Forinternaluse only. IFPAC SM 2005 Nineteenth International Forum Process Analytical Technology January 10-13, 2005 Arlington, Virginia (Washington, D.C.) U.S.A. Software Simplifies Design and Layout of Real-life NeSSI Systems John J. Wawrowski and David M. Simko Swagelok Company IFPAC IFPAC
  • date post

    21-Dec-2015
  • Category

    Documents

  • view

    214
  • download

    0

Transcript of MPC-Sample-System 1 10 MPC Sample System 6/17/04 MPC-Sample-System IFPAC SM 2005 Nineteenth...

Page 1: MPC-Sample-System 1 10 MPC Sample System 6/17/04 MPC-Sample-System IFPAC SM 2005 Nineteenth International Forum Process Analytical Technology January 10-13,

MPC-Sample-System

1 10MPC Sample System

6/17/04

MPC-Sample-System

© 2004 Swagelok Company. Swagelok confidential. For internal use only.

IFPAC SM 2005 Nineteenth International ForumProcess Analytical Technology

January 10-13, 2005 Arlington, Virginia (Washington, D.C.) U.S.A.

Software Simplifies Design and Layoutof

Real-life NeSSI Systems

John J. Wawrowski and David M. Simko Swagelok Company

IFPACIFPAC

Page 2: MPC-Sample-System 1 10 MPC Sample System 6/17/04 MPC-Sample-System IFPAC SM 2005 Nineteenth International Forum Process Analytical Technology January 10-13,

MPC-Sample-System

2 10MPC Sample System

6/17/04

MPC-Sample-System

© 2004 Swagelok Company. Swagelok confidential. For internal use only.

IFPACIFPAC

Agenda

• Review of configurator features and functionality• Live configuration of an actual system

Page 3: MPC-Sample-System 1 10 MPC Sample System 6/17/04 MPC-Sample-System IFPAC SM 2005 Nineteenth International Forum Process Analytical Technology January 10-13,

MPC-Sample-System

3 10MPC Sample System

6/17/04

MPC-Sample-System

P&ID for Sample System

Particle Filter, 2 Micron

Pressure Gauge, 0-30 psig

Pressure Regulator, 0-15 psig

Needle Valve, DK Series

Pneumatic Valve, NC

Rotameter, Brooks, 0-10 cc/min

Check Valve, crack 0-3 psi

Needle Valve, DK Series

Check Valve, crack 0-3 psi

PG

To Analyzer

QC Supply

Sample In from Process

Page 4: MPC-Sample-System 1 10 MPC Sample System 6/17/04 MPC-Sample-System IFPAC SM 2005 Nineteenth International Forum Process Analytical Technology January 10-13,
Page 5: MPC-Sample-System 1 10 MPC Sample System 6/17/04 MPC-Sample-System IFPAC SM 2005 Nineteenth International Forum Process Analytical Technology January 10-13,
Page 6: MPC-Sample-System 1 10 MPC Sample System 6/17/04 MPC-Sample-System IFPAC SM 2005 Nineteenth International Forum Process Analytical Technology January 10-13,

© 2004 Swagelok Company. Swagelok confidential. For internal use only.

Step 1: Create Configurator Layout Grid

A. File -> New

PG

IFPACIFPAC

Page 7: MPC-Sample-System 1 10 MPC Sample System 6/17/04 MPC-Sample-System IFPAC SM 2005 Nineteenth International Forum Process Analytical Technology January 10-13,

© 2004 Swagelok Company. Swagelok confidential. For internal use only.

Step 2: Place inlet(s) on the Layout Grid

A. To add these inlets…

B. Select this icon in the Toolbox…

PG

C. Then Drag it onto the Grid

IFPACIFPAC

Page 8: MPC-Sample-System 1 10 MPC Sample System 6/17/04 MPC-Sample-System IFPAC SM 2005 Nineteenth International Forum Process Analytical Technology January 10-13,

© 2004 Swagelok Company. Swagelok confidential. For internal use only.

Step 3: Add Surface Mount Positions

C. Then Drag it onto the Grid

IFPACIFPAC

A. To Add this part…

PG

B. Select this icon in the Toolbox…

Page 9: MPC-Sample-System 1 10 MPC Sample System 6/17/04 MPC-Sample-System IFPAC SM 2005 Nineteenth International Forum Process Analytical Technology January 10-13,

© 2004 Swagelok Company. Swagelok confidential. For internal use only.

Step 4 – Place outlets on GridA. To add this outlet…

B. Select this icon in the Toolbox…

PG

C. Then Drag it onto the Grid

IFPACIFPAC

Page 10: MPC-Sample-System 1 10 MPC Sample System 6/17/04 MPC-Sample-System IFPAC SM 2005 Nineteenth International Forum Process Analytical Technology January 10-13,

© 2004 Swagelok Company. Swagelok confidential. For internal use only.

Current View after Step 4

IFPACIFPAC

Page 11: MPC-Sample-System 1 10 MPC Sample System 6/17/04 MPC-Sample-System IFPAC SM 2005 Nineteenth International Forum Process Analytical Technology January 10-13,

© 2004 Swagelok Company. Swagelok confidential. For internal use only.

Step 5: Define Surface Mount PropertiesB. Right click here and select Properties. A. To Select

this part...

PG

C. To select a check valve…

D. Left click to select category here.

IFPACIFPAC

Page 12: MPC-Sample-System 1 10 MPC Sample System 6/17/04 MPC-Sample-System IFPAC SM 2005 Nineteenth International Forum Process Analytical Technology January 10-13,

© 2004 Swagelok Company. Swagelok confidential. For internal use only.

IFPACIFPAC

Current View after Step 5

Page 13: MPC-Sample-System 1 10 MPC Sample System 6/17/04 MPC-Sample-System IFPAC SM 2005 Nineteenth International Forum Process Analytical Technology January 10-13,

© 2004 Swagelok Company. Swagelok confidential. For internal use only.

Step 6: Connect Flow Paths

A. Left click starting node…

B. Valid flow path targets are displayed as green circles.

PG

IFPACIFPAC

Page 14: MPC-Sample-System 1 10 MPC Sample System 6/17/04 MPC-Sample-System IFPAC SM 2005 Nineteenth International Forum Process Analytical Technology January 10-13,

© 2004 Swagelok Company. Swagelok confidential. For internal use only.

IFPACIFPAC

Current View after Step 6

Page 15: MPC-Sample-System 1 10 MPC Sample System 6/17/04 MPC-Sample-System IFPAC SM 2005 Nineteenth International Forum Process Analytical Technology January 10-13,

© 2004 Swagelok Company. Swagelok confidential. For internal use only.

Step 7: Final Layout, BOM, and Assembly Diagram

IFPACIFPAC

Page 16: MPC-Sample-System 1 10 MPC Sample System 6/17/04 MPC-Sample-System IFPAC SM 2005 Nineteenth International Forum Process Analytical Technology January 10-13,

© 2004 Swagelok Company. Swagelok confidential. For internal use only.

Step 8 – Save the File

A. File -> Save

PG

IFPACIFPAC

Page 17: MPC-Sample-System 1 10 MPC Sample System 6/17/04 MPC-Sample-System IFPAC SM 2005 Nineteenth International Forum Process Analytical Technology January 10-13,

© 2004 Swagelok Company. Swagelok confidential. For internal use only.

Configurator Demonstration

Swagelok MPC Configurator.lnk

IFPACIFPAC

Page 18: MPC-Sample-System 1 10 MPC Sample System 6/17/04 MPC-Sample-System IFPAC SM 2005 Nineteenth International Forum Process Analytical Technology January 10-13,

© 2004 Swagelok Company. Swagelok confidential. For internal use only.

Conclusion

• Please visit us at Booths 315/317– Complimentary copy of the software– Opportunity to use it– Opportunity to build a NeSSI system

IFPACIFPAC