MP NexLevel Installation Specification Guide

55
MP NexLevel Installation Specification Guide Rev 2.0 10202013

Transcript of MP NexLevel Installation Specification Guide

Page 1: MP NexLevel Installation Specification Guide

MP NexLevelInstallation Specification Guide

Rev 2.0 10202013

Page 2: MP NexLevel Installation Specification Guide

Table of Contents

Small Loaders and Excavators 8Ditch Witch Plow Trencher and Comparable 12Astec RT960 and Comparable 16Vermeer T655 and Comparable 20Vermeer D7x11 and Comparable 25Vermeer D24x40 and Comparable 30Ditch Witch Pump Vac and Comparable 35Ingersoll Rand Compressor and Comparable 39Komatsu D65 and Comparable 43Small Bulldozers and Comparable 47Skid Steers and Comparable 52

Page 3: MP NexLevel Installation Specification Guide

Equipment Overview

MP NexLevel will be utilizing the following equipment package:

• TM470Rv9 (HEP Replacement)• PTO• Ruggedized wedge antenna with

optional bracket

All installations must be completed as set forth in this installation specification guide. Any deviation requires approval from the National Vehicle Support Manager or from the Director of Field Service. Additionally, MP NexLevel must approve all deviations.

Page 4: MP NexLevel Installation Specification Guide

MP NexLevel Installation Requirements

• All power connections must be either soldered or directly to a bus bar.• Both power leads of the TM470Rv9 must be connected to ignition, as MP Nexlevel does

not want undue drain on the equipment batteries.• All cabling must be neatly routed and run, using zip-ties to secure the wiring.• All connections made in the vehicle and all connections on the TM470R must be tamper-

sealed using the provided Torque Seal.• The TM470R must be securely mounted , with screws or nuts and bolts being preferred, as

off-highway equipment is subject to severe vibration.• Prior to contacting Verification, use the diagnostics app on the CTO7 to verify the IP, the

GPS signal, the wireless signal, the PTO status (on/off), and the ignition status (on/off).• When installing a PTO sense, ensure the correct polarity input is utilized. Due to the

severe conditions, relays to change polarity will not be acceptable to the customer.• Upon the completion of the installation, the technician must call for verification at

714.934.8770. The verification code provided at the end of the call must be notated, as it is a requirement for payment.

• When contacting the verification desk, ensure that the representative inputs the correct hour reading to ensure that the utilization reports accumulate hours correctly.

• The specifications in this guide must be followed exactly, as the equipment is extremely expensive and highly sensitive. Any deviations from specification must be approved by Randy Schmoll of MPN and Brennan Connelly or Shelton Simmons of Teletrac.

Page 5: MP NexLevel Installation Specification Guide

TM470R Internal Battery

Prior to installing the TM470Rv9, the case must be opened and the battery must be connected to the board, as shown at right. The battery is not connected prior to shipping to ensure that the battery is fully charged upon installation.

Page 6: MP NexLevel Installation Specification Guide

PTO Connections

Only a subset of equipment will be equipped to monitor PTO. The equipment-specific pages will detail as to which assets will require PTO monitoring.

There are two main types of PTOs to be connected: Seat switch and pressure transducer. The PTO connections will be made without relays, thus positive trigger PTOs will be connected to the orange wire on the TM470R harness, and negative trigger PTOs will be connected to the grey wire. It is imperative that the connections are well documented to ensure that the system is correctly configured on the back end.

Page 7: MP NexLevel Installation Specification Guide

TM470R Cabling Pinout

Pin #

MicroPlug

Function Color

1 Diag RX NA

2 Input Positive Orange

3 Ground (GND) Black

4 Input Negative Gray

5 Relay driver output (RELAY2) Blue

6 TBD NA

7 Relay driver output (RELAY1) –FIL- Yellow

8 SAE J1708 bus A signal (J1708A) Yellow (twisted with Blue)

9 CAN bus L signal (CANL) Brown (twisted with Red)

10 Diag TX NA

11 Info switch input (ISW) NA

12 Ignition Sense (IGN) White (twist 3/5/12)

13 DB9 RS232 Yellow

14 DB9 RS232 White

15 Ground (GND) Black

16 Battery supply rail (VBATT) Red

17 SAE J1708 bus B signal (J1708B) Blue (twisted with Yellow)

18 CAN bus H signal (CANH) Red (twisted with Brown)

Will be updated when new diagram available…

Page 8: MP NexLevel Installation Specification Guide

Small Loaders and Excavators

Page 9: MP NexLevel Installation Specification Guide

Small Loaders and Excavators

Power Connections: Both of the power leads from the TM470R will be connected to the switched ignition lead at the rear of the ignition switch, as shown at top right. This power source must first be verified with a digital multimeter . The ignition switch is accessed by removing the Allen screws from the metal dash bezel.

Sensor/PTO Connections: No sensor or PTO connections are required for this equipment type.

CAUTION: All power and PTO sources must be verified using a digital multimeter(DMM). The use of a test light will result in immediate termination.

All deviations from this specification must be approved by MPN and Teletrac.

Page 10: MP NexLevel Installation Specification Guide

Small Loaders and Excavators

Antenna Placement: The antenna is generally mounted beneath the plastic cover over the gauge cluster. If this location is not available, the antenna can be mounted in a logical place inside of the cab, where there is no risk of damage or interference with the operator. The antenna cable must be run through a 3/8” hole in the cover, which must be protected with a snap-grommet. The cabling must be protected with split-loom and run away from any moving parts or heat sources.

TM470R Placement: The TM470R must be secured with nuts and bolts to the inside of the lower dash panel, adjacent to the throttle, as show at lower right. On some of the smaller Komatsus, it may be necessary to securely ziptiethe device between two braces.

Page 11: MP NexLevel Installation Specification Guide

Small Loaders and Excavators

Installation Guidelines:

• All power connections must either be soldered (Wire to wire connections) or connected with ring terminals (Terminal posts/bus bars)

• Any power, sensor, or antenna connections that will be directly exposed to the elements must be protected with shrink-tubing.

• All power connections and sensor connections must be verified with a digital multimeter. Test lights are not an acceptable alternative, and their usage will result in immediate termination.

• All TM470Rs must be mounted with nuts and bolts or self-tapping screws, unless specifically noted otherwise in this guide.

• No deviations from the specifications set forth in this guide will be accepted without the approval of MPN and Teletrac.

MPN Contact: Randy Schmoll- 320.963.2847(Office) 320.241.6710 (Cell)

Teletrac contacts: Brennan Connelly- 540.313.2926 (Cell) or Shelton Simmons 713.359.8723 (Cell)

Page 12: MP NexLevel Installation Specification Guide

Ditch Witch Plow Trencher and Comparable Equipment

Page 13: MP NexLevel Installation Specification Guide

Ditch Witch Plow Trencher and Comparable Equipment

Power Connections: Both of the power leads from the TM470R will be connected to the switched ignition lead at the rear of the ignition switch, as shown at top right. This power source must first be verified with a digital multimeter . The ignition switch is accessed by raising the engine cover.

Sensor/PTO Connections: No sensor or PTO connections are required for this equipment type.

CAUTION: All power and PTO sources must be verified using a digital multimeter(DMM). The use of a test light will result in immediate termination.

All deviations from this specification must be approved by MPN and Teletrac.

Page 14: MP NexLevel Installation Specification Guide

Ditch Witch Plow Trencher and Comparable Equipment

Antenna Placement: The antenna is to be mounted to the side of the fan enclosure using self-tapping screws. The cable must be routed through a 3/8” entry hole and protected with a snap-grommet. The cabling must be protected with split-loom and run away from any moving parts or heat sources.

TM470R Placement: The TM470R must be secured with nuts and bolts the metal brace, adjacent to the battery, on the right side of the engine, as shown at bottom right.

Page 15: MP NexLevel Installation Specification Guide

Ditch Witch Plow Trencher and Comparable Equipment

Installation Guidelines:

• All power connections must either be soldered (Wire to wire connections) or connected with ring terminals (Terminal posts/bus bars)

• Any power, sensor, or antenna connections that will be directly exposed to the elements must be protected with shrink-tubing.

• All power connections and sensor connections must be verified with a digital multimeter. Test lights are not an acceptable alternative, and their usage will result in immediate termination.

• All TM470Rs must be mounted with nuts and bolts or self-tapping screws, unless specifically noted otherwise in this guide.

• No deviations from the specifications set forth in this guide will be accepted without the approval of MPN and Teletrac.

MPN Contact: Randy Schmoll- 320.963.2847(Office) 320.241.6710 (Cell)

Teletrac contacts: Brennan Connelly- 540.313.2926 (Cell) or Shelton Simmons 713.359.8723 (Cell)

Page 16: MP NexLevel Installation Specification Guide

Astec RT960 and ComparableEquipment

Page 17: MP NexLevel Installation Specification Guide

Astec RT960 and ComparableEquipment

Power Connections: Both of the power leads from the TM470R will be connected to the switched ignition lead at the rear of the ignition switch, as shown at top right. This power source must first be verified with a digital multimeter . The ignition switch is accessed by removing the gauge cluster and by removing the retaining nut on the front of the ignition switch.

Sensor/PTO Connections: No sensor or PTO connections are required for this equipment type.

CAUTION: All power and PTO sources must be verified using a digital multimeter (DMM). The use of a test light will result in immediate termination.

All deviations from this specification must be approved by MPN and Teletrac.

Page 18: MP NexLevel Installation Specification Guide

Astec RT960 and ComparableEquipment

Antenna Placement: The antenna is to be mounted to the top of the console, on the right side of the equipment. The cable must be routed through a 3/8” entry hole and protected with a snap-grommet. The cabling must be protected with split-loom and run away from any moving parts or heat sources.

TM470R Placement: The TM470R must be secured with nuts and bolts to the front panel of the equipment, behind the gauge cluster, as shown at bottom right.

Page 19: MP NexLevel Installation Specification Guide

Astec RT960 and ComparableEquipment

Installation Guidelines:

• All power connections must either be soldered (Wire to wire connections) or connected with ring terminals (Terminal posts/bus bars)

• Any power, sensor, or antenna connections that will be directly exposed to the elements must be protected with shrink-tubing.

• All power connections and sensor connections must be verified with a digital multimeter. Test lights are not an acceptable alternative, and their usage will result in immediate termination.

• All TM470Rs must be mounted with nuts and bolts or self-tapping screws, unless specifically noted otherwise in this guide.

• No deviations from the specifications set forth in this guide will be accepted without the approval of MPN and Teletrac.

MPN Contact: Randy Schmoll- 320.963.2847(Office) 320.241.6710 (Cell)

Teletrac contacts: Brennan Connelly- 540.313.2926 (Cell) or Shelton Simmons 713.359.8723 (Cell)

Page 20: MP NexLevel Installation Specification Guide

Vermeer T655 and ComparableEquipment

Page 21: MP NexLevel Installation Specification Guide

Vermeer T655 and ComparableEquipment

Power Connections: Both of the power leads from the TM470R will be connected to the switched ignition lead at the rear of the fuse panel, as shown at top right. This power source must first be verified with a digital multimeter . The rear of the fuse panel is readily accessible without removing any panels, as shown at top right.

Sensor/PTO Connections: The orange positive lead from the TM470R must be connected to the output of the after-market hydraulic sensor. Please consult MPN fleet for the location of this sensor, as it may vary from machine to machine. The lead from this sensor may be quite long, and will need to be protected with split loom. Please ensure that the routing avoids any moving parts and heat sources, and is properly secured. The entry hole into the machine must be protected with a snap-grommet.

CAUTION: All power and PTO sources must be verified using a digital multimeter (DMM). The use of a test light will result in immediate termination.

All deviations from this specification must be approved by MPN and Teletrac.

Page 22: MP NexLevel Installation Specification Guide

Vermeer T655 and ComparableEquipment

Sensor Installation: In certain pieces of equipment, MPN will be installing a hydraulic sensor. On some machines, this sensor may be just behind the gauge cluster, while on others it may be at a test port. If the location of the sensor is not readily evident, please consult a MPN fleet representative.

The sensor wiring is as follows:

• Brown- Tie into ignition source for TM470R. Fuse at 5a.

• Blue- Ground with TM470R ground wire.

• White- Positive output. Connect to Orange positive input on TM470R.

• Black- Cut short and secure. Not used for this application.

Page 23: MP NexLevel Installation Specification Guide

Vermeer T655 and ComparableEquipment

Antenna Placement: The antenna is to be mounted to the right window, without the mounting bracket, as shown at top right. The antenna cable should be neatly routed down the wiring harness.

TM470R Placement: The TM470R must be secured with nuts and bolts to the panel adjacent to the fuse panel, as shown at bottom right.

Page 24: MP NexLevel Installation Specification Guide

Vermeer T655 and ComparableEquipment

Installation Guidelines:

• All power connections must either be soldered (Wire to wire connections) or connected with ring terminals (Terminal posts/bus bars)

• Any power, sensor, or antenna connections that will be directly exposed to the elements must be protected with shrink-tubing.

• All power connections and sensor connections must be verified with a digital multimeter. Test lights are not an acceptable alternative, and their usage will result in immediate termination.

• All TM470Rs must be mounted with nuts and bolts or self-tapping screws, unless specifically noted otherwise in this guide.

• No deviations from the specifications set forth in this guide will be accepted without the approval of MPN and Teletrac.

MPN Contact: Randy Schmoll- 320.963.2847(Office) 320.241.6710 (Cell)

Teletrac contacts: Brennan Connelly- 540.313.2926 (Cell) or Shelton Simmons 713.359.8723 (Cell)

Page 25: MP NexLevel Installation Specification Guide

Vermeer D7x11 and ComparableEquipment

Page 26: MP NexLevel Installation Specification Guide

Vermeer D7x11 and ComparableEquipment

Power Connections: Both of the power leads from the TM470R will be connected to the switched ignition lead at the rear of the keyswitch, as shown at top right. This power source must first be verified with a digital multimeter .

Sensor/PTO Connections: The orange positive lead from the TM470R must be connected to the output of the after-market hydraulic sensor (If Installed). Please consult MPN fleet for the location of this sensor, as it may vary from machine to machine. The lead from this sensor may be quite long, and will need to be protected with split loom. Please ensure that the routing avoids any moving parts and heat sources, and is properly secured. The entry hole into the machine must be protected with a snap-grommet.

CAUTION: All power and PTO sources must be verified using a digital multimeter (DMM). The use of a test light will result in immediate termination.

All deviations from this specification must be approved by MPN and Teletrac.

Page 27: MP NexLevel Installation Specification Guide

Vermeer D7x11 and ComparableEquipment

Sensor Installation: In certain pieces of equipment, MPN will be installing a hydraulic sensor. On some machines, this sensor may be just behind the gauge cluster, while on others it may be at a test port. If the location of the sensor is not readily evident, please consult a MPN fleet representative.

The sensor wiring is as follows:

• Brown- Tie into ignition source for TM470R. Fuse at 5a.

• Blue- Ground with TM470R ground wire.

• White- Positive output. Connect to Orange positive input on TM470R.

• Black- Cut short and secure. Not used for this application.

Page 28: MP NexLevel Installation Specification Guide

Vermeer D7x11 and ComparableEquipment

Antenna Placement: The antenna is to be mounted to the top of the control console. The cable must be routed through a 3/8” entry hole and protected with a snap-grommet. The cabling must be protected with split-loom and run away from any moving parts or heat sources.

TM470R Placement: The TM470R must be secured with nuts and bolts to the top panel of the engine compartment, on the left side, as shown at bottom right.

Page 29: MP NexLevel Installation Specification Guide

Vermeer D7x11 and ComparableEquipment

Installation Guidelines:

• All power connections must either be soldered (Wire to wire connections) or connected with ring terminals (Terminal posts/bus bars)

• Any power, sensor, or antenna connections that will be directly exposed to the elements must be protected with shrink-tubing.

• All power connections and sensor connections must be verified with a digital multimeter. Test lights are not an acceptable alternative, and their usage will result in immediate termination.

• All TM470Rs must be mounted with nuts and bolts or self-tapping screws, unless specifically noted otherwise in this guide.

• No deviations from the specifications set forth in this guide will be accepted without the approval of MPN and Teletrac.

MPN Contact: Randy Schmoll- 320.963.2847(Office) 320.241.6710 (Cell)

Teletrac contacts: Brennan Connelly- 540.313.2926 (Cell) or Shelton Simmons 713.359.8723 (Cell)

Page 30: MP NexLevel Installation Specification Guide

Vermeer D24x40 and ComparableEquipment

Page 31: MP NexLevel Installation Specification Guide

Vermeer D24x40 and ComparableEquipment

Power Connections: Both of the power leads from the TM470R will be connected to the switched ignition lead at the rear of the keyswitch, as shown at top right. This power source must first be verified with a digital multimeter .

Sensor/PTO Connections: The orange positive lead from the TM470R must be connected to the output of the after-market hydraulic sensor. Please consult MPN fleet for the location of this sensor, as it may vary from machine to machine. The lead from this sensor may be quite long, and will need to be protected with split loom. Please ensure that the routing avoids any moving parts and heat sources, and is properly secured. The entry hole into the machine must be protected with a snap-grommet.

CAUTION: All power and PTO sources must be verified using a digital multimeter (DMM). The use of a test light will result in immediate termination.

All deviations from this specification must be approved by MPN and Teletrac.

Page 32: MP NexLevel Installation Specification Guide

Vermeer D24x40 and ComparableEquipment

Sensor Installation: In certain pieces of equipment, MPN will be installing a hydraulic sensor. On some machines, this sensor may be just behind the gauge cluster, while on others it may be at a test port. If the location of the sensor is not readily evident, please consult a MPN fleet representative.

The sensor wiring is as follows:

• Brown- Tie into ignition source for TM470R. Fuse at 5a.

• Blue- Ground with TM470R ground wire.

• White- Positive output. Connect to Orange positive input on TM470R.

• Black- Cut short and secure. Not used for this application.

Page 33: MP NexLevel Installation Specification Guide

Vermeer D24x40 and ComparableEquipment

Antenna Placement: The antenna is to be mounted to the top of the control console using nuts and bolts or self-tapping screws. The cable must be routed through a 3/8” entry hole and protected with a snap-grommet. The cabling must be protected with split-loom and run away from any moving parts or heat sources.

TM470R Placement: TBD

Need mounting picture.

Page 34: MP NexLevel Installation Specification Guide

Vermeer D24x40 and ComparableEquipment

Installation Guidelines:

• All power connections must either be soldered (Wire to wire connections) or connected with ring terminals (Terminal posts/bus bars)

• Any power, sensor, or antenna connections that will be directly exposed to the elements must be protected with shrink-tubing.

• All power connections and sensor connections must be verified with a digital multimeter. Test lights are not an acceptable alternative, and their usage will result in immediate termination.

• All TM470Rs must be mounted with nuts and bolts or self-tapping screws, unless specifically noted otherwise in this guide.

• No deviations from the specifications set forth in this guide will be accepted without the approval of MPN and Teletrac.

MPN Contact: Randy Schmoll- 320.963.2847(Office) 320.241.6710 (Cell)

Teletrac contacts: Brennan Connelly- 540.313.2926 (Cell) or Shelton Simmons 713.359.8723 (Cell)

Page 35: MP NexLevel Installation Specification Guide

Ditch Witch Pump Vac and Comparable Equipment

Page 36: MP NexLevel Installation Specification Guide

Ditch Witch Pump Vac and Comparable Equipment

Power Connections: Both of the power leads from the TM470R will be connected to the switched ignition lead at the rear of the keyswitch, as shown at top right. This power source must first be verified with a digital multimeter .

Sensor/PTO Connections: No sensor or PTO connections are required for this equipment type.

CAUTION: All power and PTO sources must be verified using a digital multimeter (DMM). The use of a test light will result in immediate termination.

All deviations from this specification must be approved by MPN and Teletrac.

Page 37: MP NexLevel Installation Specification Guide

Ditch Witch Pump VacComparable Equipment

Antenna Placement: The antenna is to be mounted to the top or side of the machine, above the access door, using nuts and bolts or self-tapping screws, as shown at top right. The cable must be routed through a 3/8” entry hole and protected with a snap-grommet.

TM470R Placement: The TM470R is to be mounted inside of the access panel using nuts and bolts or self-tapping screws, as shown at lower right.

Page 38: MP NexLevel Installation Specification Guide

Ditch Witch Pump VacComparable Equipment

Installation Guidelines:

• All power connections must either be soldered (Wire to wire connections) or connected with ring terminals (Terminal posts/bus bars)

• Any power, sensor, or antenna connections that will be directly exposed to the elements must be protected with shrink-tubing.

• All power connections and sensor connections must be verified with a digital multimeter. Test lights are not an acceptable alternative, and their usage will result in immediate termination.

• All TM470Rs must be mounted with nuts and bolts or self-tapping screws, unless specifically noted otherwise in this guide.

• No deviations from the specifications set forth in this guide will be accepted without the approval of MPN and Teletrac.

MPN Contact: Randy Schmoll- 320.963.2847(Office) 320.241.6710 (Cell)

Teletrac contacts: Brennan Connelly- 540.313.2926 (Cell) or Shelton Simmons 713.359.8723 (Cell)

Page 39: MP NexLevel Installation Specification Guide

Ingersoll Rand Compressor and Comparable Equipment

Page 40: MP NexLevel Installation Specification Guide

Ingersoll Rand Compressor and Comparable Equipment

Power Connections: Both of the power leads from the TM470R will be connected to the switched ignition lead at the rear of the keyswitch, as shown at right. This power source must first be verified with a digital multimeter .

Sensor/PTO Connections: No sensor or PTO connections are required for this equipment type.

CAUTION: All power and PTO sources must be verified using a digital multimeter (DMM). The use of a test light will result in immediate termination.

All deviations from this specification must be approved by MPN and Teletrac.

Page 41: MP NexLevel Installation Specification Guide

Ingersoll Rand Compressor and Comparable Equipment

Antenna Placement: The antenna is to be mounted to the top of the machine, above the access door, using nuts and bolts or self-tapping screws, as shown at top right. The cable must be routed through a 3/8” entry hole and protected with a snap-grommet.

TM470R Placement: The TM470R is to be mounted inside of the engine compartment, to the right of the ignition switch, using nuts and bolts or self-tapping screws, as shown at lower right.

Page 42: MP NexLevel Installation Specification Guide

Ingersoll Rand Compressor andComparable Equipment

Installation Guidelines:

• All power connections must either be soldered (Wire to wire connections) or connected with ring terminals (Terminal posts/bus bars)

• Any power, sensor, or antenna connections that will be directly exposed to the elements must be protected with shrink-tubing.

• All power connections and sensor connections must be verified with a digital multimeter. Test lights are not an acceptable alternative, and their usage will result in immediate termination.

• All TM470Rs must be mounted with nuts and bolts or self-tapping screws, unless specifically noted otherwise in this guide.

• No deviations from the specifications set forth in this guide will be accepted without the approval of MPN and Teletrac.

MPN Contact: Randy Schmoll- 320.963.2847(Office) 320.241.6710 (Cell)

Teletrac contacts: Brennan Connelly- 540.313.2926 (Cell) or Shelton Simmons 713.359.8723 (Cell)

Page 43: MP NexLevel Installation Specification Guide

Komatsu D65 and Comparable Equipment

Page 44: MP NexLevel Installation Specification Guide

Komatsu D65 and Comparable Equipment

Power Connections: Both of the power leads from the TM470R will be connected to the switched ignition on the opposite of the hot side of the master relay, as shown at top right. This power source must first be verified with a digital multimeter .

Sensor/PTO Connections: No sensor or PTO connections are required for this equipment type.

CAUTION: All power and PTO sources must be verified using a digital multimeter (DMM). The use of a test light will result in immediate termination.

All deviations from this specification must be approved by MPN and Teletrac.

Page 45: MP NexLevel Installation Specification Guide

Komatsu D65 and Comparable Equipment

Antenna Placement: The antenna is to be mounted to the left of the access door, using nuts and bolts or self-tapping screws, as shown at top right. The cable must be routed through a 3/8” entry hole and protected with a snap-grommet.

TM470R Placement: The TM470R is to be mounted to the top panel, inside of the under-seat compartment, using nuts and bolts or self-tapping screws, as shown at lower right.

Page 46: MP NexLevel Installation Specification Guide

Komatsu D65 andComparable Equipment

Installation Guidelines:

• All power connections must either be soldered (Wire to wire connections) or connected with ring terminals (Terminal posts/bus bars)

• Any power, sensor, or antenna connections that will be directly exposed to the elements must be protected with shrink-tubing.

• All power connections and sensor connections must be verified with a digital multimeter. Test lights are not an acceptable alternative, and their usage will result in immediate termination.

• All TM470Rs must be mounted with nuts and bolts or self-tapping screws, unless specifically noted otherwise in this guide.

• No deviations from the specifications set forth in this guide will be accepted without the approval of MPN and Teletrac.

MPN Contact: Randy Schmoll- 320.963.2847(Office) 320.241.6710 (Cell)

Teletrac contacts: Brennan Connelly- 540.313.2926 (Cell) or Shelton Simmons 713.359.8723 (Cell)

Page 47: MP NexLevel Installation Specification Guide

Small Bulldozers and Comparable Equipment

Page 48: MP NexLevel Installation Specification Guide

Small Bulldozers and Comparable Equipment

Power Connections: Both of the power leads from the TM470R will be connected to the switched ignition lead at the rear of the keyswitch, as shown at top right. This power source must first be verified with a digital multimeter .

Sensor/PTO Connections: The orange positive lead from the TM470R must be connected to the output of the after-market hydraulic sensor. Please consult MPN fleet for the location of this sensor, as it may vary from machine to machine. The lead from this sensor may be quite long, and will need to be protected with split loom. Please ensure that the routing avoids any moving parts and heat sources, and is properly secured. The entry hole into the machine must be protected with a snap-grommet.

CAUTION: All power and PTO sources must be verified using a digital multimeter (DMM). The use of a test light will result in immediate termination.

All deviations from this specification must be approved by MPN and Teletrac.

Page 49: MP NexLevel Installation Specification Guide

Small Bulldozers and Comparable Equipment

Sensor Installation: In certain pieces of equipment, MPN will be installing a hydraulic sensor. On some machines, this sensor may be just behind the gauge cluster, while on others it may be at a test port. If the location of the sensor is not readily evident, please consult a MPN fleet representative.

The sensor wiring is as follows:

• Brown- Tie into ignition source for TM470R. Fuse at 5a.

• Blue- Ground with TM470R ground wire.

• White- Positive output. Connect to Orange positive input on TM470R.

• Black- Cut short and secure. Not used for this application.

Page 50: MP NexLevel Installation Specification Guide

Small Bulldozers and Comparable Equipment

Antenna Placement: The antenna is to be mounted to top right of the hood, using nuts and bolts or self-tapping screws, as shown at top right. The cable must be routed through a 3/8” entry hole and protected with a snap-grommet.

TM470R Placement: The TM470R is to be mounted to a suitable dash brace, behind the gauge cluster, using nuts and bolts or self-tapping screws, as shown at lower right.

Need TM470R mounting pic.

Page 51: MP NexLevel Installation Specification Guide

Small Bulldozers andComparable Equipment

Installation Guidelines:

• All power connections must either be soldered (Wire to wire connections) or connected with ring terminals (Terminal posts/bus bars)

• Any power, sensor, or antenna connections that will be directly exposed to the elements must be protected with shrink-tubing.

• All power connections and sensor connections must be verified with a digital multimeter. Test lights are not an acceptable alternative, and their usage will result in immediate termination.

• All TM470Rs must be mounted with nuts and bolts or self-tapping screws, unless specifically noted otherwise in this guide.

• No deviations from the specifications set forth in this guide will be accepted without the approval of MPN and Teletrac.

MPN Contact: Randy Schmoll- 320.963.2847(Office) 320.241.6710 (Cell)

Teletrac contacts: Brennan Connelly- 540.313.2926 (Cell) or Shelton Simmons 713.359.8723 (Cell)

Page 52: MP NexLevel Installation Specification Guide

Skid Steers and Comparable Equipment

Need better beauty shot of skid steer…

Page 53: MP NexLevel Installation Specification Guide

Skid Steers and Comparable Equipment

Power Connections: Both of the power leads from the TM470R will be connected to the switched ignition at the rear of the keyswitch, as shown at top right. This power source must first be verified with a digital multimeter .

Sensor/PTO Connections: No sensor or PTO connections are required for this equipment type.

CAUTION: All power and PTO sources must be verified using a digital multimeter (DMM). The use of a test light will result in immediate termination.

All deviations from this specification must be approved by MPN and Teletrac.

Need picture of keyswitch.

Page 54: MP NexLevel Installation Specification Guide

Skid Steers and Comparable Equipment

Antenna Placement: The antenna is to be mounted to the top left of the roof, using nuts and bolts or self-tapping screws, as shown at top right. The cable must be routed through a 3/8” entry hole and protected with a snap-grommet.

TM470R Placement: The TM470R is to be mounted underneath the roof, forward and left, using nuts and bolts or self-tapping screws, as shown at bottom right.

Page 55: MP NexLevel Installation Specification Guide

Skid Steers andComparable Equipment

Installation Guidelines:

• All power connections must either be soldered (Wire to wire connections) or connected with ring terminals (Terminal posts/bus bars)

• Any power, sensor, or antenna connections that will be directly exposed to the elements must be protected with shrink-tubing.

• All power connections and sensor connections must be verified with a digital multimeter. Test lights are not an acceptable alternative, and their usage will result in immediate termination.

• All TM470Rs must be mounted with nuts and bolts or self-tapping screws, unless specifically noted otherwise in this guide.

• No deviations from the specifications set forth in this guide will be accepted without the approval of MPN and Teletrac.

MPN Contact: Randy Schmoll- 320.963.2847(Office) 320.241.6710 (Cell)

Teletrac contacts: Brennan Connelly- 540.313.2926 (Cell) or Shelton Simmons 713.359.8723 (Cell)