Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe...

210
Motors | Automation | Energy | Transmission & Distribution Low Voltage Switch & Control Gear Catalogue & Pricelist 2015 - 2016 Automation

Transcript of Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe...

Page 1: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

Motors | Automation | Energy | Transmission & Distribution

Low Voltage Switch & Control Gear

Catalogue & Pricelist

2015 - 2016

Automation

Page 2: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

02 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 1

Table Of Contents CWB Contactors (New Generation) - pg 2

2 Introduction

9 Selection Guide

19 Overview

20 Price List

21 Technical Data

24 Accessories

RW Thermal Overload Relay

(New Generation) - pg 26

26 Introduction

26 Selection Guide

29 Price List

30 Technical Data

MPW - Motor Protective Circuit Breaker

(New Generation) - pg 32

33 Introduction

34 Selection Guide

37 Overview

39 Price List

43 Technical Data

47 Accessories

Contactors - CWC & CWM - pg 50

50 Selection Guide

CWC - Compact Contactors - pg 54

54 Introduction

55 Overview

56 Price List

64 Technical Data

66 Accessories

CWM - Contactors - pg 97

97 Introduction

98 Price List

101 Technical Data

104 Accessories

CWMC - Capacitors switching

Contactors - pg 111

111 Introduction

112 Overview

113 Price List

Overload Relays - pg 114

114 Introduction

115 Technical Data

118 Price List

122 Accessories

MPW - pg 132

132 Overview

135 Price List

141 Technical Data

143 Accessories

DOL Starters - pg 148

154 Price List

WEG Electronic Relays - pg 157

157 Overview

169 Technical Data

173 Price List

178 Accessories

Smart Relay - pg 179

179 Overview

185 Selection Guide

187 Technical Data

195 Price LIst

196 Accessories

CSW - Pushbuttons & Pilot Lights - pg 200

200 Price List

205 Accessories

214 Technical Data

DWA/DWB - Moulded case breaker - pg 215

215 Overview

217 Technical Data

221 Price List

246 Accessories

265 Installation Information

ACW - Moulded Case Breaker - pg 268

268 Overview

274 Technical Data

275 Price List

277 Accessories

ABW - Air Circuit Breaker - pg 284

284 Overview

286 Technical Data

287 Price List

291 Accessories

MDW & MDWH - Miniature Circuit

Breakers - pg 296

296 Overview

297 Price List

High Speed Fuses - pg 307

307 Overview

310 Price List

Switch Disconnectors - pg 316

316 Overview

319 Technical Data

320 Price List

Power Factor Controller & Power Meter - pg 324

325 Overview

335 Price List

Capacitors - pg 336

336 Overview

345 Price List

357 Accessories

360 Technical Data

Terminals - pg 368

368 Overview

370 Selection Guide

387 Price List

Fanox - Electronic Motor Protection - pg 410

410 Product Selection

Selection Charts - pg 413

413 Rated Motor Current

Conversion Table

413 Electrical Formula

Due to continuous product development, item product codes & descriptions may vary and must be confirmed when placing orders.

ALALLAL PRRRRRICECEICEICICCES ESS S XCLUDEDED VAT, E&OE

wwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwww....zzzzzzzzzzzzzzzzzzzzzzzzeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeessssssssssssssssssssssssssstttttttttttttttttttttttttttttt........cccccccccccccccccccccoooooooooooooo...........zzzzzzzzzzzzzzzzzzzzzzaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa

020202 ll LOWLOW VOVOLTAL GE G SWISWITCHTCH & & CONTTROOOL GL GLL EAREAR

Industrial systems

enhancing productivity.

Page 3: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 3ALL PRICES EXCLUDE VAT, E&OE2 l LOW VOLTAGE SWITCH & CONTROL GEAR

CWB contactors are manufactured with the best raw materials from top international suppliers and with WEG high quality

components, using high precision plastic injection molds and stamping tools, ensuring very reliable products with the best

cost-benefit in the market.

Analysis of CWB electromagnetic system. Simulation of plastic injection molding of CWB contact carrier.

The Technology Within The use of finite-element analysis and state-of-the-art modeling softwares for simulation of

electromagnetic and electromechanical systems provide WEG CWB contactors with an improved

project with reduced contact bouncing. The outcome reached by WEG’s R&D team ensures a product

with long mechanical and electrical lifespan in a reduced size and with lower energy consumption.

The electric contacts of CWB contactors are manufactured with special silver alloys which ensure excellent electric

conductibility and high contact reliability. During operation, the double-break contacts and arc chutes ensure fast arc

quenching and provide high resistance against the wear effects of the electric arc and, consequently, a long electrical lifespan.

Energy Savings LOW CONSUMPTION COILS

The low-consumption coils of new WEG contactors of up to 38 A allow safe operation with minimum energy consumption of up to

6 W in DC and up to 7.5 VA in AC. Besides energy savings, the low consumption of the coils of CWB contactors allows reducing

the power supply of control transformers. When well dimensioned and properly applied, the traditional starting methods of electric

motors, such as DOL (reversing or non-reversing) and star-delta using contactors, are the safest and best cost-benefit means to

start and protect electric motors in low voltage. Up to at least 55 kW, DOL and star-delta starters using contactors are still the best

and most widely used starting methods in all kinds of industries worldwide. Even when electronic methods are used for the start

and control of motors, such as VSDs and Soft-Starters, the contactors continue to be necessary in combination with the electronic

devices. Therefore, one can only imagine the huge number of contactors installed and in operation all over the world.

Thus, CWB contactors are designed to operate in a safe and reliable way with the lowest energy consumption.

DC COILS WITH NO INRUSH PICK-UP CURRENT

Besides low energy consumption, DC coils allow direct control

of CWB contactors via PLC or digital outputs of devices such

as VSDs or Soft-Starters without the need of interface relays.

PLC VSDSS

Coil Consumption

DC Operated Contactor

Energy saving

30%

Standard contactor CWB

Eco-FriendlyThe CWB line uses only nontoxic and eco-friendly materials that are safe and sustainable.

Page 4: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE4 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za www.zest.co.za

ALL PRICES EXCLUDE VAT, E&OE LOW VOLTAGE SWITCH & CONTROL GEAR l 5

Easy Panel Optimisation COMPACT SOLUTION

Because they are compact, 45 mm wide and available in up to

38 A (18.5 kW@ 380 / 415 V AC-3 and 25 hp @ 480 V UL 3-ph),

CWB contactors lead to an overall reduction in size of electric

panels if compared to traditional solutions of contactors with the

same ratings.

BUILT-IN AUXILIARY CONTACTS 1NO + 1NC

The configuration of two built-in auxiliary contacts

(1NO + 1NC) makes the application of CWB contactors

more flexible in most automation systems, contributing

to the optimization of internal space of electrical panels.

55 mm

45 mm

Allows

+1

Contactor

“ZERO-WIDTH” MECHANICAL INTERLOCK

For applications which require mechanical interlock between contactors, WEG has developed a new mechanical system that

ensures compact and easy mounting without the need of any tools. WEG’s new mechanical interlock system allows the

mechanical interlock between two contactors of the CWB line with “zero” additional side space and it is possible to assemble

90 mm wide reversing starters of up to 38 A.

90 mm 2 x 45 mm

SIMPLE AND COMPACT MOUNTING OF

SURGE SUPPRESSOR BLOCKS

The coils of CWB contactors operate smoothly with

a low level of disturbance in the control circuits.

However, in order to reduce voltage surges due to

the coil switching even further, WEG has developed

surge suppressor blocks especially for the CWB line

of contactors, which ensure limitation or even

completely eliminate the undesired interferences

that may be caused on opening the contactor coil.

Surge suppressor blocks are easily mounted on

CWB contactors without the need of any kind of

tools and also without increasing volume.

MORE SIMPLE AND ORGANISED CONTROL

CIRCUITS

In order to optimize space in electric panels even

more, the WEG CWB contactor line has a front

channel for the passage of control cables.

This could reduce or eliminate the need of control

cable passage through the side or front part of

contactors providing a “cleaner” and more

organized assembly of the control circuit.

CONTACTOR COIL OPERATED ON AC OR DC

Wide range of voltages available in only two coil

versions (one for AC and another for DC) to fit the

whole range of contactors from 9 to 38 A.

Easy AC coil replacement and visual coil voltage

indication.

Contactor with AC coil Contactor with DC coil

Standard ContactorsCWB Line

Page 5: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE6 l LOW VOLTAGE SWITCH & CONTROL GEAR LOW VOLTAGE SWITCH & CONTROL GEAR l 7

Flexibility and Modularity in Assembly of Electric PanelsEASY-CONNECTION BUSBARS AND CONNECTORS

The harmonious integration between the WEG CWB line of contactors and overload relays and motor protective circuit breakers

allows fast and easy assembly of compact starters and protection sets of LV electric motors with excellent cost-benefit.

The modularity and flexibility of easy-connection busbars and connectors reduce assembly time, besides preventing errors.

Available for CWB contactors up to 38 A, easy-connection allows the combined assembly with WEG motor protective circuit

breakers and thermal overload relays forming compact and robust DOL starters (reversing and non-reversing) and

star-delta starters.

ADDITIONAL CONTACT BLOCKS

Besides the 1NO + 1NC built-in auxiliary contacts, in order to meet the most complex control needs, WEG has also developed

auxiliary high performance contact blocks which can be easily mounted on the front or side of CWB contactors, allowing the

combination of up to six auxiliary contacts per contactor up to 38 A.

An important characteristic of the side auxiliary contact blocks of the CWB line is the small dimension (only 9 mm wide) which

meets the requirements of modularity, allowing more compact combinations of motor starters with motor protective circuit

breakers when easy-connection busbars are used.

PANEL ASSEMBLY FLEXIBILITY

CWB contactors can be easily assembled on panels

using 35 mm DIN rails or screws because their

oblong holes are compatible with the old and

traditional lines of contactors on the market.

EASY ACCESS POWER AND CONTROL TERMINALS

All power terminals, auxiliary contacts and coils provide users with fast front access, facilitating installation, measurements and

interventions for preventive and corrective maintenance of starters.

Page 6: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE8 l LOW VOLTAGE SWITCH & CONTROL GEAR LOW VOLTAGE SWITCH & CONTROL GEAR l 9

SafetySAFETY AGAINST ACCIDENTAL CONTACT

All power and control terminals of CWB contactors have IP20 degree of protection, ensuring total safety against accidental frontal

contact.

SAFETY-RELATED APPLICATIONS

In automation systems of machines and equipment, it is common to use special contactors in combination with specific safety

relays. The new WEG CWB contactors allow this combination due to the arrangement of the contacts which meets IEC 60947-4-1

Annex F (Mirror Contact) and IEC 60947-5-1 Annex L (Mechanically Linked Contact) requirements.

IEC 60947-5-1

Mechanically linked

contacts

IEC 60947-4-1

Mirror contacts

THREE-POLE CWB CONTACTORS FROM 9 UP TO 38 A (AC-3)

Note: to complete the reference code, replace “ ” by the appropriate coil voltage code.

Coil voltage code D02 D07 D13 D15 D17 D77 D23 D24 D25 D33 D34 D35 D36 D39 D45

V (50/60 Hz) 24 48 110 120 127 208 220 230 240 380 400 415 440 480 600

Coil voltage code C02 C03 C07 C09 C12 C13 C15

V dc 12 24 48 60 110 125 220

Selection Guide

Note: other coil voltages available upon request.

Ie máx.

(Ue ≤440 V)

Ie = Ith

(Ue ≤690 V)

≤55 °C

Orientative rated operational power of three-phase

motors 50/60 Hz

Built-in auxiliary contacts

per contactor

Reference code

Weight

AC-3

A

AC-1

A

220 V

240 V

kW/ hp

380 V

400 V

kW/ hp

415 V

440 V

kW/ hp

500 V

kW/ hp

660 V

690 V

kW/ hp 4

3

NO

2

1

NC

AC coil

kg

DC coil

kg

9 25 2.2 / 3 3.7 / 5 4.5 / 6 5.5 / 7.5 5.5 / 7.5 1 1 CWB9-11-30 0.404 0.525

12 25 3 / 4 5.5 / 7.5 5.5 / 7.5 7.5 / 10 7.5 / 10 1 1 CWB12-11-30 0.404 0.525

18 32 4.5 / 6 7.5 / 10 9.2 / 12.5 9.2 / 12.5 11 / 15 1 1 CWB18-11-30 0.404 0.525

25 40 5.5 / 7.5 11 / 15 11 / 15 15 / 20 15 / 20 1 1 CWB25-11-30 0.408 0.529

32 50 7.5 / 10 15 / 20 15 / 20 18.5 / 25 18.5 / 25 1 1 CWB32-11-30 0.408 0.529

38 50 9.2 / 12.5 18.5 / 25 18.5 / 25 18.5 / 25 18.5 /25 1 1 CWB38-11-30 0.408 0.529

Page 7: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

10 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 11

Direct On Line Starter

Hand / auto / reset button Overload protection Allows assembly on a DIN rail by fixing a

single component

Motor current In

(A)

Contactor AC-3 Overload relay CWB + RW27-2D

Total weight

(kg)Reference code

Maximum rated

current AC-3

(A)

Reference code

Setting overload

release I

(A)

Maximum gL/gG fuse

(type 1 coordination)

(A)

Maximum gL/gG fuse

(type 2 coordination)

(A)

0.28...0.4 CWB9-11-30 9 RW27-2D3-D004 0.28...0.4 2 2 0.57

0.43...0.63 CWB9-11-30 9 RW27-2D3-C063 0.43...0.63 2 2 0.57

0.56...0.8 CWB9-11-30 9 RW27-2D3-D008 0.56...0.8 2 2 0.57

0.8...1.2 CWB9-11-30 9 RW27-2D3-D012 0.8...1.2 4 4 0.57

1.2...1.8 CWB9-11-30 9 RW27-2D3-D018 1.2...1.8 6 6 0.57

1.8...2.8 CWB9-11-30 9 RW27-2D3-D028 1.8...2.8 6 6 0.57

2.8...4 CWB9-11-30 9 RW27-2D3-U004 2.8...4 10 10 0.57

4...6.3 CWB9-11-30 9 RW27-2D3-D063 4...6.3 16 16 0.57

5.6...8 CWB9-11-30 9 RW27-2D3-U008 5.6...8 20 20 0.57

7...9 CWB9-11-30 9 RW27-2D3-U010 7...10 25 25 0.57

8...12 CWB12-11-30 12 RW27-2D3-D125 8...12.5 25 25 0.57

10...15 CWB18-11-30 18 RW27-2D3-U015 10...15 35 35 0.57

11...17 CWB18-11-30 18 RW27-2D3-U017 11...17 40 35 0.57

15...23 CWB25-11-30 25 RW27-2D3-U023 15...23 50 50 0.57

22...32 CWB32-11-30 32 RW27-2D3-U032 22...32 63 63 0.57

25...38 CWB38-11-30 38 RW27-2D3-U040 25...40 90 80 0.57

Coil voltage code D02 D07 D13 D15 D17 D77 D23 D24 D25 D33 D34 D35 D36

V (50/60 Hz) 24 48 110 120 127 208 220 230 240 380 400 415 440

Coil voltage code C02 C03 C07 C09 C12 C13 C15

V dc 12 24 48 60 110 125 220

Notes: Orientative values valid for operational voltages up to 440 V, site altitude up to 2000 m, temperature range of -20 oC...+55 oC and maximum switching

frequency up to 15 operations/hour.

For other conditions verify technical data of each individual component.

CWB Contactor + RW27-2D Thermal Overload Relay

Remote load switching Phase-loss sensitivity Tripping class 10 Temperature compensation

TO COMPLETE THE REFERENCE CODE, REPLACE “ ” BY THE APPROPRIATE COIL VOLTAGE CODE

K1

1

2

1

3 5

2

4

3

4

6

5

6

FT1

Supply disconnecting device

acc. to IEC 60204-1 Pushbutton operated Short-circuit protection High short-circuit breaking capacity Fixed short-circuit release 13xIu Overload protection

Motor current In

(A)

Contactor AC-3 Motor protective circuit breaker Accessories

Total weight

(kg)

Reference code

Maximum rated

current AC-3

(A)

Reference code

Setting overload

release I

(A)

Instantaneous

magnetic trip

Irm

(A)

Link module

0.1...0.16 CWB9-11-30 9 MPW18-3-C016 0.1...0.16 2.0

ECCMP-18B38 (CWB - AC coil)

0.71

0.16...0.25 CWB9-11-30 9 MPW18-3-C025 0.16...0.25 3.2 0.71

0.25...0.4 CWB9-11-30 9 MPW18-3-D004 0.25...0.4 5.2 0.71

0.4...0.63 CWB9-11-30 9 MPW18-3-C063 0.4...0.63 8.1 0.71

0.63...1 CWB9-11-30 9 MPW18-3-U001 0.63...1 13 0.71

1...1.6 CWB9-11-30 9 MPW18-3-D016 1...1.6 20.8 0.71

1.6...2.5 CWB9-11-30 9 MPW18-3-D025 1.6...2.5 32.5 0.71

2.5...4 CWB9-11-30 9 MPW18-3-U004 2.5...4 52 0.71

4...6.3 CWB9-11-30 9 MPW18-3-D063 4...6.3 81.9 0.71

6.3...10 CWB12-11-30 12 MPW18-3-U010 6.3...10 130 0.71

10...16 CWB18-11-30 18 MPW18-3-U016 10...16 208 0.71

16...18 CWB18-11-30 18 MPW18-3-U020 16...20 260 0.71

Notes: Orientative values valid for operational voltages up to 440 V, site altitude up to 2000 m, temperature range of -20 oC...+55 oC and maximum switching

frequency up to 15 operations/hour.

For other conditions verify technical data of each individual component.

MPW18 Motor Protective Circuit Breaker + CWB Contactor

Coil voltage code D02 D07 D13 D15 D17 D77 D23 D24 D25 D33 D34 D35 D36

V (50/60 Hz) 24 48 110 120 127 208 220 230 240 380 400 415 440

Coil voltage code C02 C03 C07 C09 C12 C13 C15

V dc 12 24 48 60 110 125 220

Allows assembly on a DIN rail by fixing a single

component Remote load switching Phase-loss sensitivity Tripping class 10 Temperature compensation

Direct On Line Starter

TO COMPLETE THE REFERENCE CODE, REPLACE “ ” BY THE APPROPRIATE COIL VOLTAGE CODE

1

Q1

3 5

2 4 6

1 3 5

2 4 6K1

Page 8: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

12 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 13

Motor current In

(A)

Contactor AC-3 Motor protective circuit breaker Accessories

Total weight

(kg)

Reference code

Maximum rated

current AC-3

(A)

Reference code

Setting overload

release I

(A)

Instantaneous

magnetic trip

Irm

(A)

Link module

0.1...0.16 CWB9-11-30 9 MPW40-3-C016 0.1...0.16 2.0

ECCMP-40B38 (CWB - AC coil) ECCMP-40B38DC (CWB - DC coil)

0.79

0.16...0.25 CWB9-11-30 9 MPW40-3-C025 0.16...0.25 3.2 0.79

0.25...0.4 CWB9-11-30 9 MPW40-3-D004 0.25...0.4 5.2 0.79

0.4...0.63 CWB9-11-30 9 MPW40-3-C063 0.4...0.63 8.1 0.79

0.63...1 CWB9-11-30 9 MPW40-3-U001 0.63...1 13 0.79

1...1.6 CWB9-11-30 9 MPW40-3-D016 1...1.6 20.8 0.79

1.6...2.5 CWB9-11-30 9 MPW40-3-D025 1.6...2.5 32.5 0.79

2.5...4 CWB9-11-30 9 MPW40-3-U004 2.5...4 52 0.79

4...6.3 CWB9-11-30 9 MPW40-3-D063 4...6.3 81.9 0.79

6.3...10 CWB12-11-30 12 MPW40-3-U010 6.3...10 130 0.79

10...16 CWB18-11-30 18 MPW40-3-U016 10...16 208 0.79

16...20 CWB25-11-30 25 MPW40-3-U020 16...20 260 0.79

20...25 CWB25-11-30 25 MPW40-3-U025 20...25 325 0.79

25...32 CWB32-11-30 32 MPW40-3-U032 25...32 416 0.79

32...38 CWB38-11-30 38 MPW40-3-U040 32...40 520 0.79

Coil voltage code D02 D07 D13 D15 D17 D77 D23 D24 D25 D33 D34 D35 D36

V (50/60 Hz) 24 48 110 120 127 208 220 230 240 380 400 415 440

Coil voltage code C02 C03 C07 C09 C12 C13 C15

V dc 12 24 48 60 110 125 220

Notes: Orientative values valid for operational voltages up to 440 V, site altitude up to 2000 m, temperature range of -20 oC...+55 oC and maximum switching

frequency up to 15 operations/hour.

For other conditions verify technical data of each individual component.

Supply disconnecting device

acc. to IEC 60204-1 Rotary handle operated Short-circuit protection High short-circuit breaking capacity Fixed short-circuit release 13xIu Overload protection

MPW40 Motor Protective Circuit Breaker + CWB Contactor

Allows assembly on a DIN rail by fixing a single

component Remote load switching Phase-loss sensitivity Tripping class 10 Temperature compensation

Direct On Line Starter

TO COMPLETE THE REFERENCE CODE, REPLACE “ ” BY THE APPROPRIATE COIL VOLTAGE CODE

1

Q1

3 5

2 4 6

1 3 5

2 4 6K1

Hand / auto / reset button Overload protection Allows assembly on a DIN rail by fixing

a single component

Motor current In

(A)

Contactor AC-3 Overload relay Accessories CWB + RW27-2D

Total weight

(kg)Reference code

Maximum rated

current AC-3

(A)

Reference code

Setting overload

release I

(A)

Mechanical

interlock kit

Easy connection

busbars

Maximum gL/gG

fuse (type 1 co-

ordination)

(A)

Maximum gL/gG

fuse (type 2 co-

ordination)

(A)

0.28...0.4 CWB9-11-30 9 RW27-2D3-D004 0.28...0.4

IM1 EC-R1

2 2 1.02

0.43...0.63 CWB9-11-30 9 RW27-2D3-C063 0.43...0.63 2 2 1.02

0.56...0.8 CWB9-11-30 9 RW27-2D3-D008 0.56...0.8 2 2 1.02

0.8...1.2 CWB9-11-30 9 RW27-2D3-D012 0.8...1.2 4 4 1.02

1.2...1.8 CWB9-11-30 9 RW27-2D3-D018 1.2...1.8 6 6 1.02

1.8...2.8 CWB9-11-30 9 RW27-2D3-D028 1.8...2.8 6 6 1.02

2.8...4 CWB9-11-30 9 RW27-2D3-U004 2.8...4 10 10 1.02

4...6.3 CWB9-11-30 9 RW27-2D3-D063 4...6.3 16 16 1.02

5.6...8 CWB9-11-30 9 RW27-2D3-U008 5.6...8 20 20 1.02

7...9 CWB9-11-30 9 RW27-2D3-U010 7...10 25 25 1.02

8...12 CWB12-11-30 12 RW27-2D3-D125 8...12.5 25 25 1.02

10...15 CWB18-11-30 18 RW27-2D3-U015 10...15 35 35 1.02

11...17 CWB18-11-30 18 RW27-2D3-U017 11...17 40 35 1.02

15...23 CWB25-11-30 25 RW27-2D3-U023 15...23 50 50 1.03

22...32 CWB32-11-30 32 RW27-2D3-U032 22...32 63 63 1.03

25...38 CWB38-11-30 38 RW27-2D3-U040 25...40 90 80 1.03

Note: Orientative values valid for operational voltages up to 440 V, site altitude up to 2000 m, temperature range of -20 oC...+55 oC and maximum switching

frequency up to 15 operations/hour.

For other conditions, verify technical data of each individual component.

CWB Contactors + RW27-2D Thermal Overload Relay

Coil voltage code D02 D07 D13 D15 D17 D77 D23 D24 D25 D33 D34 D35 D36

V (50/60 Hz) 24 48 110 120 127 208 220 230 240 380 400 415 440

Coil voltage code C02 C03 C07 C09 C12 C13 C15

V dc 12 24 48 60 110 125 220

Remote load switching Phase-loss sensitivity Tripping class 10 Temperature compensation

Reversing Starter

TO COMPLETE THE REFERENCE CODE, REPLACE “ ” BY THE APPROPRIATE COIL VOLTAGE CODE

K1 K2IM11

2 4 6

2

FT1

4 6

2 4 6

3 5

1 3 5

1 3 5

Page 9: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

14 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 15

Supply disconnecting device

acc. to IEC 60204-1 Pushbutton operated Short-circuit protection High short-circuit breaking capacity Fixed short-circuit release 13xIu Overload protection

Motor current In

(A)

Contactor AC-3 Motor protective circuit breaker Accessories

Total weight

(kg)K1 = K2

Maximum rated

current AC-3

(A)

Reference code

Setting overload

release I

(A)

Instantaneous

magnetic trip

Irm

(A)

Link moduleMechanical

interlock kit

Easy connection

busbars

0.1...0.16 CWB9-11-30 9 MPW18-3-C016 0.1...0.16 2.0

ECCMP18B38

(CWB - AC coil)IM1 EC-R1

1.138

0.16...0.25 CWB9-11-30 9 MPW18-3-C025 0.16...0.25 3.2 1.138

0.25...0.4 CWB9-11-30 9 MPW18-3-D004 0.25...0.4 5.2 1.138

0.4...0.63 CWB9-11-30 9 MPW18-3-C063 0.4...0.63 8.1 1.138

0.63...1 CWB9-11-30 9 MPW18-3-U001 0.63...1 13 1.138

1...1.6 CWB9-11-30 9 MPW18-3-D016 1...1.6 20.8 1.138

1.6...2.5 CWB9-11-30 9 MPW18-3-D025 1.6...2.5 32.5 1.138

2.5...4 CWB9-11-30 9 MPW18-3-U004 2.5...4 52 1.138

4...6.3 CWB9-11-30 9 MPW18-3-D063 4...6.3 81.9 1.138

6.3...10 CWB12-11-30 12 MPW18-3-U010 6.3...10 130 1.138

10...16 CWB18-11-30 18 MPW18-3-U016 10...16 208 1.138

16...18 CWB18-11-30 18 MPW18-3-U020 16...20 260 1.138

Note: Orientative values valid for operational voltages up to 440 V, site altitude up to 2000 m, temperature range of -20 oC...+55 oC and maximum switching

frequency up to 15 operations/hour.

For other conditions, verify technical data of each individual component.

MPW18 Motor Protective Circuit Breaker + CWB Contactors

Coil voltage code D02 D07 D13 D15 D17 D77 D23 D24 D25 D33 D34 D35 D36

V (50/60 Hz) 24 48 110 120 127 208 220 230 240 380 400 415 440

Coil voltage code C02 C03 C07 C09 C12 C13 C15

V dc 12 24 48 60 110 125 220

Allows assembly on a DIN rail by fixing a

single component Remote load switching Phase-loss sensitivity Tripping class 10 Temperature compensation

Reversing Starter

TO COMPLETE THE REFERENCE CODE, REPLACE “ ” BY THE APPROPRIATE COIL VOLTAGE CODE

K1

IM1

1

Q1

3 5

1 3 5 1 3 5

2 4 6

2 4 6

K2 K3

2 4 6

1 3 5

2 4 6

Supply disconnecting device

acc. to IEC 60204-1 Rotary handle operated Short-circuit protection High short-circuit breaking capacity Fixed short-circuit release 13xIu

Motor current In

(A)

Contactor AC-3 Motor protective circuit breaker Accessories

Total weight

(kg)K1 = K2

Maximum rated

current AC-3

(A)

Reference code

Setting overload

release I

(A)

Instantaneous

magnetic trip

Irm

(A)

Link moduleMechanical

interlock kit

Easy connection

busbars

0.1...0.16 CWB9-11-30 9 MPW40-3-C016 0.1...0.16 2.0

ECCMP-40B38

(CWB - AC coil)IM1 EC-R1

1.218

0.16...0.25 CWB9-11-30 9 MPW40-3-C025 0.16...0.25 3.2 1.218

0.25...0.4 CWB9-11-30 9 MPW40-3-D004 0.25...0.4 5.2 1.218

0.4...0.63 CWB9-11-30 9 MPW40-3-C063 0.4...0.63 8.1 1.218

0.63...1 CWB9-11-30 9 MPW40-3-U001 0.63...1 13 1.218

1...1.6 CWB9-11-30 9 MPW40-3-D016 1...1.6 20.8 1.218

1.6...2.5 CWB9-11-30 9 MPW40-3-D025 1.6...2.5 32.5 1.218

2.5...4 CWB9-11-30 9 MPW40-3-U004 2.5...4 52 1.218

4...6.3 CWB9-11-30 9 MPW40-3-D063 4...6.3 81.9 1.218

6.3...10 CWB12-11-30 12 MPW40-3-U010 6.3...10 130 1.218

10...16 CWB18-11-30 18 MPW40-3-U016 10...16 208 1.218

16...20 CWB25-11-30 25 MPW40-3-U020 16...20 260 1.226

20...25 CWB25-11-30 25 MPW40-3-U025 20...25 325 1.226

25...32 CWB32-11-30 32 MPW40-3-U032 25...32 416 1.226

32...38 CWB38-11-30 38 MPW40-3-U040 32...40 520 1.226

Note: Orientative values valid for operational voltages up to 440 V, site altitude up to 2000 m, temperature range of -20 oC...+55 oC and maximum switching

frequency up to 15 operations/hour.

For other conditions, verify technical data of each individual component.

MPW40 Motor Protective Circuit Breaker + CWB Contactors

Coil voltage code D02 D07 D13 D15 D17 D77 D23 D24 D25 D33 D34 D35 D36

V (50/60 Hz) 24 48 110 120 127 208 220 230 240 380 400 415 440

Coil voltage code C02 C03 C07 C09 C12 C13 C15

V dc 12 24 48 60 110 125 220

Overload protection Allows assembly on a DIN rail by fixing a single component Remote load switching Phase-loss sensitivity Tripping class 10 Temperature compensation

Reversing Starter

TO COMPLETE THE REFERENCE CODE, REPLACE “ ” BY THE APPROPRIATE COIL VOLTAGE CODE

K1

1

Q1

3 5

1 3 5 1 3 5

2 4 6

2 4 6

K2

2 4 6

IM1

Page 10: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

16 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 17

Hand / auto / reset button Overload protection Allows assembly on a DIN rail by

fixing a single component

Motor

current In

(A)

Contactor AC-3 Overload relay Accessories CWB + RW27-2D

Total weight

(kg)Δ Contactor

(K1 and K2)

Y Contactor

(K3)Reference code

Setting

overload

release I (A)

Mechanical

interlock kit

Easy

connection

busbars

Electronic

timer Y - Δ

Maximum gL/gG

fuse (type 1 co-

ordination) (A)

Maximum gL/gG

fuse (type 2 co-

ordination) (A)

0.5...0.7 CWB9-11-30 CWB9-11-30 RW27-2D3-D004 0.28...0.4

IM1 EC-SD1RTW ET02-MATE05

2 2 1.12

0.7...1.1 CWB9-11-30 CWB9-11-30 RW27-2D3-C063 0.4...0.63 2 2 1.12

1.1...1.4 CWB9-11-30 CWB9-11-30 RW27-2D3-D008 0.63...0.8 2 2 1.12

1.4...2.1 CWB9-11-30 CWB9-11-30 RW27-2D3-D012 0.8...1.2 4 4 1.12

2.1...3.1 CWB9-11-30 CWB9-11-30 RW27-2D3-D018 1.2...1.8 6 6 1.12

3.1...4.8 CWB9-11-30 CWB9-11-30 RW27-2D3-D028 1.8...2.8 6 6 1.12

4.8...6.9 CWB9-11-30 CWB9-11-30 RW27-2D3-U004 2.8...4 10 10 1.12

6.9...10.9 CWB9-11-30 CWB9-11-30 RW27-2D3-D063 4...6.3 16 16 1.12

9.6...13.8 CWB9-11-30 CWB9-11-30 RW27-2D3-U008 5.6...8 20 20 1.12

12.1...17.2 CWB12-11-30 CWB9-11-30 RW27-2D3-U010 7...10 25 25 1.12

13.8...21.6 CWB18-11-30 CWB9-11-30 RW27-2D3-D125 8...12.5 25 25 1.12

17.2...25.9 CWB18-11-30 CWB9-11-30 RW27-2D3-U015 10...15 35 35 1.12

19...29.3 CWB18-11-30 CWB12-11-30 RW27-2D3-U017 11...17 40 35 1.12

25.9...39.7 CWB25-11-30 CWB18-11-30 RW27-2D3-U023 15...23 50 50 1.12

37.9...55.2 CWB32-11-30 CWB25-11-30 RW27-2D3-U032 22...32 63 63 1.13

43.1...65.5 CWB38-11-30 CWB25-11-30 RW27-2D3-U040 25...40 90 80 1.13

Coil voltage code D02 D07 D13 D15 D17 D77 D23 D24 D25 D33 D34 D35 D36

V (50/60 Hz) 24 48 110 120 127 208 220 230 240 380 400 415 440

Coil voltage code C02 C03 C07 C09 C12 C13 C15

V dc 12 24 48 60 110 125 220

CWB Contactor + RW27-2D Thermal Overload Relay

Note: Orientative values valid for operational voltages up to 440 V, site altitude up to 2000 m, temperature range of -20 oC...+55 oC and maximum

switching frequency up to 15 operations/hour.

For other conditions verify technical data of each individual component.

Electronic timer relay is not shown in the picture.

Remote load switching Phase-loss sensitivity Tripping class 10 Temperature compensation

Star-Delta Starter

TO COMPLETE THE REFERENCE CODE, REPLACE “ ” BY THE APPROPRIATE COIL VOLTAGE CODE

K1

IM11 3 5 1 3 5

2 4 6

K2 K3

2 4 6

1 3 5

2 4 6

2

FT1

4 6

1 3 5

Supply disconnecting device acc. to

IEC 60204-1 Pushbutton operated Short-circuit protection High short-circuit breaking capacity Fixed short-circuit release 13xIu

Motor current In

(A)

Contactor AC-3 Motor protective circuit breaker Accessories

Total weight

(kg)Δ Contactor

(K1 and K2)

Y Contactor

(K3)Reference code

Setting

overload

release I

(A)

Instantaneous

magnetic trip

Irm

(A)

Link moduleMechanical

interlock kit

Easy

connection

busbars

Electronic

timer Y - Δ

0.1...0.16 CWB9-11-30 CWB9-11-30 MPW18-3-C016 0.1...0.16 2.0

ECCMP-18B38 (CWB - AC coil)

IM1 EC-SD1RTW ET

02-MATE05

1.258

0.16...0.25 CWB9-11-30 CWB9-11-30 MPW18-3-C025 0.16...0.25 3.2 1.258

0.25...0.4 CWB9-11-30 CWB9-11-30 MPW18-3-D004 0.25...0.4 5.2 1.258

0.4...0.63 CWB9-11-30 CWB9-11-30 MPW18-3-C063 0.4...0.63 8.1 1.258

0.63...1 CWB9-11-30 CWB9-11-30 MPW18-3-U001 0.63...1 13 1.258

1...1.6 CWB9-11-30 CWB9-11-30 MPW18-3-D016 1...1.6 20.8 1.258

1.6...2.5 CWB9-11-30 CWB9-11-30 MPW18-3-D025 1.6...2.5 32.5 1.258

2.5...4 CWB9-11-30 CWB9-11-30 MPW18-3-U004 2.5...4 52 1.258

4...6.3 CWB9-11-30 CWB9-11-30 MPW18-3-D063 4...6.3 81.9 1.258

6.3...10 CWB9-11-30 CWB9-11-30 MPW18-3-U010 6.3...10 130 1.258

10...16 CWB12-11-30 CWB9-11-30 MPW18-3-U016 10...16 208 1.258

12...18 CWB12-11-30 CWB9-11-30 MPW18-3-U018 12...18 260 1.258

Note: Orientative values valid for operational voltages up to 440 V, site altitude up to 2000 m, temperature range of -20 oC...+55 oC and maximum switching

frequency up to 15 operations/hour.

For other conditions verify technical data of each individual component.

Electronic timer relay is not shown in the picture.

MPW18 Motor Protective Circuit Breaker + CWB Contactor

Coil voltage code D02 D07 D13 D15 D17 D77 D23 D24 D25 D33 D34 D35 D36

V (50/60 Hz) 24 48 110 120 127 208 220 230 240 380 400 415 440

Coil voltage code C02 C03 C07 C09 C12 C13 C15

V dc 12 24 48 60 110 125 220

Overload protection Allows assembly on a DIN rail by fixing a single component Remote load switching Phase-loss sensitivity Tripping class 10 Temperature compensation

Star-Delta Starter

TO COMPLETE THE REFERENCE CODE, REPLACE “ ” BY THE APPROPRIATE COIL VOLTAGE CODE

K1

IM1

1

Q1

3 5

1 3 5 1 3 5

2 4 6

2 4 6

K2 K3

2 4 6

1 3 5

2 4 6

Page 11: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

18 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 19

Supply disconnecting device acc. to

IEC 60204-1 Rotary handle operated Short-circuit protection High short-circuit breaking capacity Fixed short-circuit release 13xIu

Coil voltage code D02 D07 D13 D15 D17 D77 D23 D24 D25 D33 D34 D35 D36

V (50/60 Hz) 24 48 110 120 127 208 220 230 240 380 400 415 440

Coil voltage code C02 C03 C07 C09 C12 C13 C15

V dc 12 24 48 60 110 125 220

Note: Orientative values valid for operational voltages up to 440 V, site altitude up to 2000 m, temperature range of -20 oC...+55 oC and maximum switching

frequency up to 15 operations/hour.

For other conditions verify technical data of each individual component.

Electronic timer relay is not shown in the picture.

MPW40 Motor Protective Circuit Breaker + CWB Contactor

Overload protection Allows assembly on a DIN rail by fixing a single component Remote load switching Phase-loss sensitivity Tripping class 10 Temperature compensation

Star-Delta Starter

TO COMPLETE THE REFERENCE CODE, REPLACE “ ” BY THE APPROPRIATE COIL VOLTAGE CODE

K1

IM1

1

Q1

3 5

1 3 5 1 3 5

2 4 6

2 4 6

K2 K3

2 4 6

1 3 5

2 4 6

Motor current In

(A)

Contactor AC-3 Motor protective circuit breaker Accessories

Total weight

(kg)Δ Contactor

(K1 and K2)

Y Contactor

(K3)Reference code

Setting

overload

release I

(A)

Instantaneous

magnetic trip

Irm

(A)

Link moduleMechanical

interlock kit

Easy

connection

busbars

Electronic

timer

Y - Δ

0.1...0.16 CWB9-11-30 CWB9-11-30 MPW40-3-C016 0.1...0.16 2.0

ECCMP-40B38

(CWB - AC coil)

ECCMP-

40B38DC

(CWB - DC coil)

IM1 EC-SD1RTW ET

02-MATE05

1.34

0.16...0.25 CWB9-11-30 CWB9-11-30 MPW40-3-C025 0.16...0.25 3.2 1.34

0.25...0.4 CWB9-11-30 CWB9-11-30 MPW40-3-D004 0.25...0.4 5.2 1.34

0.4...0.63 CWB9-11-30 CWB9-11-30 MPW40-3-C063 0.4...0.63 8.1 1.34

0.63...1 CWB9-11-30 CWB9-11-30 MPW40-3-U001 0.63...1 13 1.34

1...1.6 CWB9-11-30 CWB9-11-30 MPW40-3-D016 1...1.6 20.8 1.34

1.6...2.5 CWB9-11-30 CWB9-11-30 MPW40-3-D025 1.6...2.5 32.5 1.34

2.5...4 CWB9-11-30 CWB9-11-30 MPW40-3-U004 2.5...4 52 1.34

4...6.3 CWB9-11-30 CWB9-11-30 MPW40-3-D063 4...6.3 81.9 1.34

6.3...10 CWB9-11-30 CWB9-11-30 MPW40-3-U010 6.3...10 130 1.34

10...16 CWB12-11-30 CWB9-11-30 MPW40-3-U016 10...16 208 1.34

16...20 CWB12-11-30 CWB9-11-30 MPW40-3-U020 16...20 260 1.34

20...25 CWB18-11-30 CWB9-11-30 MPW40-3-U025 20...25 325 1.34

25...32 CWB25-11-30 CWB12-11-30 MPW40-3-U032 25...32 416 1.34

32...40 CWB25-11-30 CWB18-11-30 MPW40-3-U040 32...40 520 1.34

Overview

1 - Contactors CWB9...38

2 - Front mounted auxiliary contact blocks BFB

3 - Side mounted auxiliary contact blocks BLB

4 - Side mounted auxiliary contact blocks BLRB

5 - Mechanical interlock kit IM1

6 - Easy connection for reversing starters EC-R1

7 - Easy connection for star-delta starters EC-SD1

8 - Surge suppressor blocks RCB, VRB, DIB and DIZB

6

7

1 1

3

3

5

1

1

8

2

2

Page 12: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

20 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 21

3-Pole CWB Contactors

CONTACTORS CWB - 9 TO 38 A - SCREW TYPE

CONTACTORS CWB - 9 TO 38 A - DC COIL - SCREW TYPE

TYPERATED POWER

AC-3 / 400 V (kW)

RATED CURRENTAUX. CONTACTS

STOCK CODE PRICE EACH

(ZAR)D02 (24 V) D13 (110 V) D24 (230 V) D34 (400 V)Ie AC-3 I

th AC-1

CWB9-11-30 9 3,7 25 1NO + 1NC 12660800 12660801 12772076 12679490 357,00

CWB12-11-30 12 5,5 25 1NO + 1NC 12660803 12660804 12772148 12679492 374,00

CWB18-11-30 18 7,5 32 1NO + 1NC 12660806 12660807 12772150 12679493 400,00

CWB25-11-30 25 11 45 1NO + 1NC 12232934 12232934 12527889 12679494 492,00

CWB32-11-30 32 15 60 1NO + 1NC 12240777 12240798 12527893 12679495 679,00

CWB38-11-30 38 18,5 60 1NO + 1NC 12232937 12233028 12527895 12679496 789,00

TYPERATED POWER

AC-3 / 400 V (kW)

RATED CURRENTAUX. CONTACTS

STOCK CODE PRICE EACH

(ZAR)C03 (24 VDC) C12 (110 VDC) C15 (220 VDC)Ie AC-3 I

th AC-1

CWB9-11-30 9 3,7 25 1NO + 1NC 12542197 12542262 12542264 482,00

CWB12-11-30 12 5,5 25 1NO + 1NC 12542260 12542263 12542265 522,00

CWB18-11-30 18 7,5 32 1NO + 1NC 12542266 12542267 12542268 593,00

CWB25-11-30 25 11 45 1NO + 1NC 12240635 12240636 12240637 788,00

CWB32-11-30 32 15 60 1NO + 1NC 12240801 12240802 12240803 1086,00

CWB38-11-30 38 18,5 60 1NO + 1NC 12240668 12240669 12240671 1167,00

Contactors - Technical Data

MAIN CONTACTS

Reference code CWB9 CWB12 CWB18 CWB25 CWB32 CWB38

Rated operational current Ie

AC-3 (Ue ≤440 V) (A) 9 12 18 25 32 38

AC-4 (Ue ≤440 V) (A) 4.4 5.8 8.5 10.4 13.7 13.7

AC-1 ( ≤55 ºC, Ue ≤690 V) (A) 25 25 32 40 50 50

Rated operational voltage Ue IEC 60947-4-1 (V) 690

UL, CSA (V) 600

Rated thermal current Ith ( ≤55 ºC) (A) 25 25 32 40 50 50

Making capacity - IEC 60947 (A) 250 250 300 450 550 550

Breaking capacity

IEC 60947

Ue ≤440 V (A) 250 250 300 450 550 550

Ue = 500 V (A) 220 220 250 350 450 450

Ue = 690 V (A) 150 150 180 250 350 350

Short-time current (no current

flowing during recovery time of

15min and ≤40 ºC)

1s (A) 210 210 240 380 400 430

10s (A) 105 105 145 240 260 310

1min (A) 61 61 84 120 138 150

10min (A) 30 30 40 50 60 60

Protection against short-circuits

with fuses (gL/gG)

@600 V - UL/CSA (kA) 5

Coordination type 1 (A) 20 25 35 40 63 63

Impedance per pole (mΩ) 2.5 2.5 2.5 2 2 2

Power dissipation per poleAC-1 (W) 1.5 1.5 2.5 3.2 5 5

AC-3 (W) 0.2 0.4 0.8 1.2 2 3

Utilization category AC-1

Rated operational current Ie AC-3

Ue ≤440 V (A) 9 12 18 25 32 38

Ue ≤500 V (A) 7.9 11 15.8 23 28.5 28.5

Ue ≤690 V (A) 7 9 12 16.5 21 21

Orientative rated

operational power

of three-phase motors

50/60 Hz

IV poles - 1800 rpm

220 / 240 V (kW) 2.2 3 4.5 5.5 7.5 9.2

(hp) 3 4 6 7.5 10 12.5

380 / 400 V (kW) 3.7 5.5 7.5 11 15 18.5

(hp) 5 7.5 10 15 20 25

415 / 440 V (kW) 4.5 5.5 9.2 11 15 18.5

(hp) 6 7.5 12.5 15 20 25

500 V (kW) 5.5 7.5 9.2 15 18.5 18.5

(hp) 7.5 10 12.5 20 25 25

660 / 690 V (kW) 5.5 7.5 11 15 18.5 18.5

(hp) 7.5 10 15 20 25 25

Utilization category AC-4

Rated operational current Ie AC-4

Ue ≤440 V (A) 4.4 5.8 8.5 10.4 13.7 13.7

Ue ≤500 V (A) 3.9 5.1 7.5 12 13.9 13.9

Ue ≤690 V (A) 2.8 3.7 5.4 12 12.8 12.8

Orientative rated

operational power

of three-phase motors

50/60 Hz

IV poles - 1800 rpm

(200000 cycles)

220 / 240 V (kW) 1.5 1.5 2.2 3 3.7 3.7

(hp) 2 2 3 4 5 5

380 / 400 V (kW) 2.2 3.7 3.7 5.5 7.5 7.5

(hp) 3 5 5 7.5 10 10

415 / 440 V (kW) 2.2 3 3.7 5.5 7.5 7.5

(hp) 3 4 5 7.5 10 10

500 V (kW) 2.2 3 5.5 7.5 9.2 9.2

(hp) 3 4 7.5 10 12.5 12.5

660 / 690 V (kW) 2.2 3 5.5 9.2 11 11

(hp) 3 4 7.5 12.5 15 15

The New Generation of WEG Components for Motor Starting and Protection

Page 13: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

22 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 23

MAIN CONTACTS

AUXILIARY CONTACTS

Reference code

CWB9 CWB12 CWB18 CWB25 CWB32 CWB38

Utilization category AC-1

3P (NO)

Conventional thermal current Ith ( ≤55 ºC) (A) 25 25 32 40 50 50

Rated operational current ≤60 ºC (Ue ≤690 V) (A) 25 25 32 40 50 50

Max. operational power ≤55 ºC

(three-phase resistors)

220 / 240 V (kW) 9.5 9.5 12 15 19 19

380 / 400 V (kW) 16.5 16.5 21 26 33 33

415 / 440 V (kW) 19 19 24.5 30.5 38 38

500 V (kW) 21.5 21.5 27.5 34.5 43 43

660 / 690 V (kW) 28.5 28.5 36.5 45.5 57 57

Current values for connection of

2 poles in parallel Ie x 1.7

3 poles in parallel Ie x 2.4

4 poles in parallel Ie x 3.2

Percentage of maximum

operational current600 ops./h (%) 100 100 100 100 100 100

Reference code CWB9...38 (built-in) BFB (front mounted) BLB (side mounted)

Standards IEC 60947-5-1

Rated insulation voltage Ui

(pollution degree 3)

IEC 60947-4-1 (V) 1000

UL, CSA (V) 600

Rated operational voltage UeIEC 60947-4-1 (V) 690

UL, CSA (V) 600

Conventional thermal current Ith ( ≤55 ºC) (A) 10

Rated operational current Ie

AC-15 (IEC 60947-5-1)

220 / 230 V (A) 10

380 / 440 V (A) 4

500 V (A) 2.5

660 / 690 V (A) 1.5

DC-13 (IEC 60947-5-1)

24 V (A) 4

48 V (A) 2

110 V (A) 0.7

220 V (A) 0.3

440 V (A) 0.15

600 V (A) 0.1

Making capacity Ue ≤690 V 50/60 Hz - AC-15 (A) 10 x Ie

Breaking capacity Ue ≤400 V 50/60 Hz - AC-15 (A) 1 x Ie

Short-circuit protection max. fuse (gL/gG) (A) 10

Control circuit reliability (V / mA) 17 / 5

Electrical lifespan (million cycles) 1

Mechanical lifespan (million cycles) 10

Non-overlapping time between NO and NC contacts (ms) 1.5

Impedance per pole (m ) 2.5

Contactors - Technical Data

GENERAL DATA

Reference code CWB9 CWB12 CWB18 CWB25 CWB32 CWB38

Standards IEC 60947-1, IEC 60947-4-1, IEC 60947-5-1, UL 508

Rated insulation voltage Ui

(pollution degree 3)

IEC 60947-4-1 (V) 690 V

UL, CSA (V) 600 V

Rated impulse withstand voltage Uimp IEC 60947-1 (kV) 6 kV

Rated operational frequency (Hz) 25...400

Mechanical lifespanAC coil (million cycles) 10

DC coil (million cycles) 10

Electrical lifespan Ie AC-3 (million cycles) 1.5 1.5 1.2 1.2 1.2 1.2

Degree of protection (IEC 60529)Main circuit IP20 (front)

Control circuit and auxiliary contacts IP20 (front)

Mounting By screws or DIN 35 mm rail (EN 50022)

Number of coil terminalsAC operated contactors 2

DC operated contactors 2

Vibration resistance

(IEC 60068-2-6)

Open contactor (g) 4

Closed contactor at Uc (g) 4

Shock resistance

(½ sine wave =11ms - IEC 60068-2-27)

Open contactor (g) 10 10

Closed contactor at Uc (g) 15 15

Ambient temperatureOperating -25 ºC...+55 ºC

Storage -55 ºC...+80 ºC

Altitude - rated values up to1) 3000 m

CONTROL CIRCUIT - ALTERNATING CURRENT (AC)

Reference code CWB9...38

Rated insulation voltage Ui

(pollution degree 3)

IEC 60947-4-1 (V) 1000

UL, CSA (V) 600

Standard coil voltages 50/60 Hz (V) 12...600

Coil operating limits (xUs) 0.8...1.1

Coil 50/60 HzPick up (xUs) up to 0.8 for 50 Hz / up to 0.85 for 60 Hz

Drop out (xUs) 0.3...0.6

Power consumption 60 Hz operation 50 Hz operation

Coil 50/60 Hz

Sealing (VA) 7.5 9

Power factor (cos ) 0.75 0.75

Pick up (VA) 75 90

Operation time(Normally open) contact closing (ms) 15...25

(Normally open) contact opening (ms) 8...12

Thermal power dissipation 50/60 Hz (W) 5...7

Reference code CWB9...38

Rated insulation voltage Ui

(pollution degree 3)

IEC 60947-4-1 (V) 1000

UL, CSA (V) 600

Standard coil voltages 50/60 Hz (V) 12...500

Coil operating limits (xUs) 0.8...1.1

Pick up (xUs) up to 0.8

Drop out (xUs) 0.2...0.6

Power consumption For 1.0 x Us and cold coil

Sealing (W) 5.8

Pick up (W) 5.8

Operation time(Normally open) contact closing (ms) 35...45

(Normally open) contact opening (ms) 8...12

Average thermal power dissipation (W) 5.8

CONTROL CIRCUIT - DIRECT CURRENT (DC)

Note: 1) For site altitudes of 3000 to 4000 m, the adjustment factors are (0.90 x Ie and 0.80 x Ui) and for site altitudes of 4000 to 5000 m, the adjustment factors

are (0.80 x Ie and 0.75 x Ui).

Contactors - Technical Data

Page 14: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

24 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 25

Accessories for CWB Contactors

Note : Contactors and mechanical interlock kits must be bought separately.

AUXILIARY CONTACT BLOCKS - FRONTAL MOUNTING

TYPE DESCRIPTION

RATED POWER COMPONENTS

STOCK CODEPRICE EACH

(ZAR)220-240 V

(kW)

380-415 V

(kW)K1 = K2 K3

EC-SD1Star-delta starter

busbar

3.7 7.5 CWB9 CWB9

12241230 387,00

5.5 9.2 CWB12 CWB9

7.5 11 CWB18 CWB9

9.2 15 CWB18 CWB12

11 22 CWB25 CWB18

15 22 CWB32 CWB18

18.5 30 CWB38 CWB25

BUSBARS STAR-DELTA STARTER / EC-SD1 - EASY CONNECTION

AUXILIARY CONTACT BLOCKS - SIDE MOUNTING

BUSBARS REVERSING STARTER / EC-R1 - EASY CONNECTION

TYPE DESCRIPTION

RATED POWER COMPONENTS

STOCK CODEPRICE EACH

(ZAR)220-240 V

(kW)

380-415 V

(kW)K1 = K2 BLIM

EC-R1Reversing starter

busbar

2.2 3.7 CWB9

IM1 12241229 288,00

3 5.5 CWB12

4.5 7.5 CWB18

5.5 11 CWB25

7.5 15 CWB32

9.2 18.5 CWB38

TYPE MOUNTING TO USE WITH AUX. CONTACTS STOCK CODEPRICE EACH

(ZAR)

BFB-20

Frontal

CWB9...CWB38 2NO 12122434 108,00

BFB-11 CWB9...CWB38 1NO + 1NC 12123053 108,00

BFB-02 CWB9...CWB38 2NC 12122946 108,00

BFB-40 CWB9...CWB38 4NO 12122947 188,00

BFB-22 CWB9...CWB38 2NO + 2NC 12123051 188,00

BFB-04 CWB9...CWB38 4NC 12123048 188,00

BFB-31 CWB9...CWB38 3NO + 1NC 12123049 188,00

BFB-13 CWB9...CWB38 1NO + 3NC 12123052 188,00

TYPE MOUNTING TO USE WITH AUX. CONTACTS STOCK CODEPRICE EACH

(ZAR)

BLB-11

Side

CWB9...CWB38 1NO + 1NC 12187899 105,00

BLB-20 CWB9...CWB38 2NO 12187334 105,00

BLB-02 CWB9...CWB38 2NC 12187898 105,00

BLRB-11 CWB9...CWB38 1NO + 1NC 12230321 119,00

BLRB-20 CWB9...CWB38 2NO 12230319 119,00

BLRB-02 CWB9...CWB38 2NC 12230320 119,00

MECHANICAL INTERLOCK

TYPE TO USE WITH STOCK CODEPRICE EACH

(ZAR)

IM1 CWB9...CWB38 1) 12244300 44,00

Note : 1) For interlocking two contactors with AC coils or two contactors with DC coils.

The interlocking of one contactor with AC coil with another with DC coil is not possible.

TYPE TO USE WITH RATED VOLTAGE STOCK CODEPRICE EACH

(ZAR)

RCB D53

CWB9...38

(AC coil)

24...48 V 50/60 Hz 12242511 123,00

RCB D55 50...127 V 50/60 Hz 12242512 123,00

RCB D63 130...250 V 50/60 Hz 12242513 123,00

RCB D49 12...24 V 50/60 Hz 12260887 123,00

RCB D68 270...380 V 50/60 Hz 12260948 123,00

RCB D73 400...510 V 50/60 Hz 12260949 123,00

VRB D73 400...510 V 50/60 Hz 12242558 123,00

VRB E49

CWB9...38

(AC and/or DC coil)

12...48 V 50/60 Hz / 12...60 V (dc / cc) 12242514 123,00

VRB E34 50...127 V 50/60 Hz / 60...180 V (dc / cc) 12242515 123,00

VRB E50 130...250 V 50/60 Hz / 180...300 V (dc / cc) 12242516 123,00

VRB E41 277...380 V 50/60 Hz / 300...510 V (dc / cc) 12242517 123,00

DIB C33 CWB9...38

(DC coil)

12...600 V (dc / cc) 12242560 123,00

DIZB C26 12...250 V (dc / cc) 12242561 123,00

SURGE SUPPRESSOR BLOCK

TYPE TO USE WITH RATED VOLTAGE 50/60 Hz STOCK CODEPRICE EACH

(ZAR)

BRB-38 CWB9...38

D02 (24 V) 12243117 93,00

D07 (48 V) 12657821 93,00

D13 (110 V) 12243218 93,00

D23 (220 V) 12243219 93,00

D24 (230 V) 12679407 93,00

D25 (240 V) 12679440 93,00

D33 (380 V) 12243220 93,00

D34 (400 V) 12657822 93,00

D35 (415 V) 12679438 93,00

D36 (440 V) 12679441 93,00

AC COILS ²)

Note : 2) Spare DC coils not available.

Article numbers for other rated voltages and frequencies upon request.

- Smart code of the rated voltage.

Accessories for CWB Contactorsccctttttttooorrrsss

The New Generation of WEG Components for Motor Starting and Protection wwwww..zestt.coo.zzaa

ooonnntttttttaaaccctttttttooorrrsss

The New Generation of WEG Components for Motor Starting and Protection

Page 15: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

26 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 27

GENERAL INFORMATION

1 - Identification tag

2 - Multifunction RESET / TEST button

3 - Current setting dial

4 - Auxiliary contact terminals

5 - Main contact terminals

3

1

2

4

5

APPLICATIONS

RW thermal overload relays have been designed to protect three-phase and single-phase AC motors and direct current

motors1). When the RW thermal overload relays are intended to protect single-phase AC loads or DC loads, the connection

should be made as shown in the diagrams on page 38.

RW THERMAL OVERLOAD RELAYS IN CONTACTOR ASSEMBLIES FOR WYE-DELTA STARTERS

When using thermal overload relays in conjunction with contactor assemblies for wye-delta starters, it should be taken into

consideration that only 0.58 (√3 / 3) x the motor current flows through the main contactor. An overload relay mounted on the

main contactor must be set to the same multiple of the motor current.

A second overload relay may be mounted on the wye contactor if it is desired the load to be optimally protected in wye

operation. The wye current is 1/3 of the rated motor current. The relay must then be set to this current.

PROTECTION AGAINST SHORT-CIRCUIT

The RW thermal overload relays must be protected against short-circuits by fuses or circuit breakers.

AMBIENT AIR TEMPERATURE COMPENSATION

RW thermal overload relays are temperature compensated. Its trip point is not affected by temperature, and it performs

consistently at the same value of current. The time-current characteristics of RWs refer to a stated value of ambient air

temperature within the range of -20 °C to +60 °C and are based on no previous loading of the overload relay (i.e. from an initial

cold state). For ambient air temperature within the range of +60 °C up +80 °C (maximum ambient air temperature), the current

correction factor shown in the table below should be applied:

Ambient air temperature Current correction factor

65 °C 0.94

70 °C 0.87

75 °C 0.81

80 °C 0.73

Note: 1) Models RW317 and RW407 should be used only with electric motors in alternating current.

DESCRIPTION

RW thermal overload relays are designed to be

combined with contactors to assemble motor

starters.

Thermal overload relays are very reliable devices

intended to protect motors, controllers and

branch-circuit conductors against phase failures

and overloads that cause excessive heating.

The thermal overload relay has no power

contacts and cannot disconnect the motor by

itself. Motor overloads or phase failures increase

the motor current. This current increase trips the

mechanism and switches the auxiliary contacts.

The auxiliary contacts, when properly wired in

series with the coil of the contactor will de-

energize the contactor when an overload occurs.

Thus, the contactor disconnects the power to

the motor and stops its operation. The bimetallic

thermal overload relays have thermal memory.

Once tripped, the relay will not reset until it has

cooled down, allowing the motor to cool before it

can be re-started.

Thermal Overload Relay Thermal Overload Relay

SITE ALTITUDE COMPENSATION

The site altitude and hence the air density play a role with respect to the cooling conditions and dielectric withstand voltage.

A site altitude of up to 2000 m is considered as normal in accordance with IEC 60947. For higher altitudes, the current settings

on the thermal overload relay should be higher than the motor rated current. On the other hand, the operational voltage must

be reduced.

For site altitudes higher than 2000 m, the values for the current and voltage shown in the table below should be applied:

Altitude above

sea level (m)

Adjustment factor on

the current settingMaximum operational voltage Ue (V)

2000 1.00 x In

690

3000 1.05 x In

550

4000 1.08 x In

480

5000 1.12 x In

420

Min

180

120

90

60

40

20

10

6

4

2

1

Sec

60

40

20

tA

10

0.6 0.8

xln x setting current

1.5

56

4

2

1

1 2 3 4 5 6 8 10

3-pole load, symmetrical

2-pole load on a 3-pole relay

CHARACTERISTIC TRIPPING CURVE

Thermal overload relays are designed to mimic the heat

actually generated in the motor. As the motor temperature

increases, so does the temperature of the overload relay

thermal unit.

The motor and relay heating curves have a strong

relationship. No matter how high the current drawn by the

motor, the thermal overload relay provides protection and yet,

does not trip unnecessarily.

Thus, the characteristic tripping curves indicate how the

tripping time, starting from the cold state, varies with the

current for multiples of the full-load current for three-pole

symmetrical loads.

PHASE FAILURE SENSITIVITY

In order to ensure fast tripping in case of phase loss,

protecting the motor and avoiding expensive repairs /

corrective maintenance services, RW27-2D thermal overload

relays include phase failure sensitivity protection as standard.

For this purpose, they have a differential release mechanism

that, in the case of phase failure, ensures the de-energized

cooled down bimetal strip to generate an additional tripping

displacement (simulating an overcurrent that actually doesn’t

exist). This way, in the event of phase failure, the differential

release ensures tripping at a lower current than with a three-

phase load (characteristic curve below).

However, for more effective protection against phase failure,

specific protective products should be evaluated ensuring

that such failure is detected much faster. The curve below

shows the tripping time in relation to the rated current. It is

also considered average values of the tolerance range and at

ambient temperature of 20 °C starting from the cold state.

Page 16: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

28 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 29

MULTIFUNCTION RESET / TEST BUTTON

The thermal overload relay has a multifunction RESET / TEST button that can be set in four different positions:

A - Automatic RESET only;

AUTO - Automatic RESET / TEST;

HAND - Manual RESET / TEST;

H - Manual RESET only.

In HAND and AUTO positions, when RESET button is pressed, both NO (97-98) and NC (95-96) contacts change states.

Operation description:

In H (manual RESET only) or A (automatic RESET only) position, the test function is blocked. However in the positions HAND

(manual RESET / TEST) or AUTO (automatic RESET / TEST) it is possible to simulate the test and the trip functions by pressing

the RESET button.

When set in the H or HAND position the RESET button must be pressed manually to reset the overload relay after a tripping

event. On the other hand, when set in A or AUTO position, the overload relay will reset automatically after a tripping event.

The H, HAND, AUTO and A function setting is carried out by rotating without pressing the red button and placing it on the

desired position of the RESET button.

When changing from HAND to AUTO, the RESET button must be slightly pressed while the red button is rotated.

Functions H HAND AUTO A

Relay reset Manual1) Manual1) Automatic Automatic

Auxiliary contact trip test 95-96 (NC) Function is disabled Test is allowed Test is allowed Function is disabled

Auxiliary contact trip test 97-98 (NO) Function is disabled Test is allowed Test is allowed Function is disabled

Thermal Overload Relay

Note: 1) A recovery time of a few minutes is necessary before resetting the thermal overload relay.

RECOVERY TIME

The RW thermal overload relays have thermal memory.

After tripping due to an overload, the relay requires a certain

period of time for the bimetal strips to cool down. This period

of time is so-called recovery time. The relay can only be reset

once it has cooled down. The recovery time depends on the

characteristic tripping curves and the level of the tripping

current. After tripping due to overload, the recovery time

allows the load to cool down.

OPERATION IN THE OUTPUT SIDE OF FREQUENCY

INVERTERS

The RW27-2D thermal overload relays are designed for

operation on 50/60 Hz up to 400 Hz and the tripping values

are related to the heating by currents within this frequency

range. Depending on the design of the frequency inverter, the

switching frequency can reach several kHz and generate

harmonic currents at the output that result in additional

temperature rise in the bimetal strips. In such applications,

the temperature rise not only depends on the rms value of

the current, but on the induction effects of the higher

frequency currents in the metal parts of the device (skin

effect caused by eddy currents).

Due to these effects, the current settings on the overload

relay should be higher than the motor rated current.

RW27-2D Thermal Overload Relay

TYPE RANGE (A) DIRECT MOUNTING ON STOCK CODEPRICE EACH

(ZAR)

RW27-2D3-D004 0.28...0.4 CWB9...38 12140441 451,00

RW27-2D3-C063 0.43...0.63 CWB9...38 12140442 451,00

RW27-2D3-D008 0.56...0.8 CWB9...38 12140443 451,00

RW27-2D3-D012 0.8...1.2 CWB9...38 12140444 451,00

RW27-2D3-D018 1.2...1.8 CWB9...38 12140445 451,00

RW27-2D3-D028 1.8...2.8 CWB9...38 12140446 451,00

RW27-2D3-U004 2.8...4 CWB9...38 12140447 451,00

RW27-2D3-D063 4...6.3 CWB9...38 12140448 451,00

RW27-2D3-U008 5.6...8 CWB9...38 12140449 451,00

RW27-2D3-U010 7...10 CWB9...38 12140450 451,00

RW27-2D3-D125 8...12.5 CWB9...38 12140451 451,00

RW27-2D3-U015 10...15 CWB9...38 12140452 451,00

RW27-2D3-U017 11...17 CWB9...38 12140453 468,00

RW27-2D3-U023 15...23 CWB9...38 12140454 468,00

RW27-2D3-U032 22...32 CWB9...38 12140455 515,00

RW27-2D3-U040 32...40 CWB9...38 12140456 592,00

3-POLE THERMAL OVERLOAD RELAY

RW27D

TYPE RANGE (A) DIRECT MOUNTING ON STOCK CODEPRICE EACH

(ZAR)

RW27-2D2-D004 0.28...0.43 CWB9...38 12140369 424,00

RW27-2D2-C063 0.43...0.63 CWB9...38 12140370 424,00

RW27-2D2-D008 0.56...0.8 CWB9...38 12140372 424,00

RW27-2D2-D012 0.8...1.2 CWB9...38 12140373 424,00

RW27-2D2-D018 1.2...1.8 CWB9...38 12140375 424,00

RW27-2D2-D028 1.8...2.8 CWB9...38 12140377 424,00

RW27-2D2-U004 2.8...4 CWB9...38 12140409 424,00

RW27-2D2-D063 4...6.3 CWB9...38 12140410 424,00

RW27-2D2-U008 5.6...8 CWB9...38 12140411 424,00

RW27-2D2-U010 7...10 CWB9...38 12140412 424,00

RW27-2D2-D125 8...12.5 CWB9...38 12140413 424,00

RW27-2D2-U015 10...15 CWB9...38 12140414 424,00

RW27-2D2-U017 11...17 CWB9...38 12140415 440,00

RW27-2D2-U023 15...23 CWB9...38 12140416 440,00

RW27-2D2-U032 22...32 CWB9...38 12140438 484,00

RW27-2D2-U040 32...40 CWB9...38 12140439 556,00

2-POLE THERMAL OVERLOAD RELAY

RW27D

wwwww..zestt.coo.zzaa

oooaaadddddd RRRRRReeellllllaaayyy

N STOCK

The New Generation of WEG Components for Motor Starting and Protection

Page 17: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

30 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 31

MAIN CONTACTS

Technical Data

Models RW27

Standards IEC 60947-1 and UL 508

Rated insulation voltage Ui

(pollution degree 3)

IEC 60947-4-1 (V) 690

UL, CSA (V) 600

Rated impulse withstand voltage Uimp (IEC 60947-1) (kV) 6

Rated operational frequency (Hz) 25...400

Use with direct current Yes

Maximum operation per hour (ops./h) 15

Protection degree (IEC 60529)

Main contacts IP10

Auxiliary contacts IP20

Frontal IP20

Mounting Direct on the contactor

Resistance to impact (IEC 60068-2-27 - 1/2 sinusoid) (g/ms) 10/11

Ambient temperature

Transport and storage -50 ºC...+80 ºC

Operating -20 ºC...+70 ºC

Temperature compensation -20 ºC...+60 ºC

Altitude (m) 2000

MAIN DATA

Models RW27

Rated operational voltage UeIEC 60947-4-1 (V) 690

UL, CSA (V) 600

Setting current / max fuse (gL/gG)1)(A)

0.28...0.4 / 2

0.43...0.63 /2

0.56...0.8 / 2

0.8...1.2 / 4

1.2...1.8 / 6

1.8...2.8 / 6

2.8...4 / 10

4...6.3 / 16

5.6... 8 / 20

7...10 / 25

8...12.5 / 25

10...15 / 35

11...17 / 40

15...23 / 50

22...32 / 63

32...40 / 90

Average power dissipation per pole (W) ≤3

Models RW27

Type of screwsM4 x 10

Phillips

Cable size

Flexible cable (mm²) 1.5...10

Cable with terminal / rigid cable (mm²) 1.5...6.0

AWG-wire 14...6

Tightening torque (N.m) 2.3

Technical Data

TERMINAL CAPACITY AND TIGHTENING TORQUE - MAIN CONTACTS

TERMINAL CAPACITY AND TIGHTENING TORQUE - AUXILIARY CONTACTS

Models RW27

Standards IEC 60 947-4-1 and UL 508

Rated insulation voltage Ui

(pollution degree 3)

IEC (V) 690

UL, CSA (V) 600

Rated operational voltage UeIEC (V) 690

UL, CSA (V) 600

Rated thermal current Ith ( ≤55 ºC) (A) 6

Rated operational current Ie

AC-14 / AC-15 (IEC 60947-5-1)

24 V (A) 4

60 V (A) 3.5

125 V (A) 3

230 V (A) 2

400 V (A) 1.5

500 V (A) 0.5

690 V (A) 0.3

UL, CSA C600

DC-13 / DC-14 (IEC 60947-5-1)

24 V (A) 1

60 V (A) 0.5

110 V (A) 0.25

220 V (A) 0.1

UL, CSA R300

Short-circuit protection with fuse (gL/gG) (A) 6

Minimum voltage / admissible current (IEC 60947-5-4) 17 V / 5 mA

Models RW27

Type of screwsM3.5 x 10

Philips

Cable size

Cable with or without terminal (mm²) 2 x 1...2.5

AWG-wire 16...12

Tightening torque (N.m) 1.5

Page 18: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

32 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 33

www.weg.net

C-32 Motor Control and Protection up to 18.5 kW/ 25 hp

www.weg.net

Developed according to IEC 60947 and UL 508 international standards, the new WEG MPW line of

motor protective circuit breakers are modular and compact but at the same time robust and highly

reliable, meeting the expectations of the most demanding users.

The MPWs are designed with the visual identity of WEG, a brand recognized worldwide for its quality.

MPW40 Motor protective circuit breaker up to 40 A - 45 mm wide Thermal-magnetic circuit breaker (provides protection

against short-circuit and overload) or only magnetic circuit

breaker (provides protection against short-circuit) Same technical features (mechanical and electrical) of

former MPW25 (up to 32 A) Rotary handle operated

MPW12 Motor protective circuit breaker up to 12 A with spring

clamp terminals Thermal-magnetic circuit breaker (provides protection

against short-circuit and overload) or only magnetic

circuit breaker (provides protection against short-circuit) Same technical features (mechanical and electrical) of

former MPW16 (up to 12 A) Pushbutton operated

MPW18 Motor protective circuit breaker up to 18 A Thermal-magnetic circuit breaker (provides protection

against short-circuit and overload) or only magnetic circuit

breaker (provides protection against short-circuit) Same technical features (mechanical and electrical) of

former MPW16 (up to 16 A) Pushbutton operated

New WEG MPW Motor Circuit Breakers

Note: 1) UL certification may not be available for specific products or

current ranges.

For further information consult your sales representative.

1)

Motor Protective Circuit Breakers

of MPW line, the best solution for

operating and protection of

your electric motor.

CHARACTERISTICS

Type Conventional starter Compact starter

Number of components 3 components (fuse1) + contactor+ termal O/L relay) 1 component (motor circuit breaker termomagnetic)

Short-circuit protection Yes Yes

Switching Yes Yes

Motor overload protection Yes Yes

Reset after short-circuit No Yes

Reset after overload Yes Yes

Overall dimension Larger Smaller

Mounting time Long Short

Scale cover No Yes (with accessory)

Safety disconnect for maintenance Fuse removal Padlock on handle/button in OFF position

Operational status signalling No Yes

Protection degree Smaller Bigger

Number of connections Bigger Smaller

Maximum operation per hour 15 operations/hour 15 operations/hour

Operation mode Remote Manual

3 Functions in a Single Product!

Switching

Overload

protection

Short-circuit

protectionI >

Electrical DiagramElectrical Diagram

Short-circuit

protection

Switching

Overload

protection

Note: 1) Fuse installed on fuse holders IP00.

ElElectriical Dl Diiagram

Page 19: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

34 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 35

Reference values for selecting protection of three-phase electric motors1)

Rated current

In (A)

Setting overload

release

In (A)

Instantaneous

magnetic trip

13 x In

Im (A)

Screw terminal

Weight

kg220-240 V

kW/ hp

380-415 V

kW/ hp

440-480 V

kW/ hp

500 V

kW/ hp

550-600 V

kW/ hp

690 V

kW/ hpReference code

- - - - - - 0.16 0.1...0.16 2.08 MPW18-3-C016

0.28

- - - - - 0.12 / 0.16 0.25 0.16...0.25 3.25 MPW18-3-C025

- - 0.12 / 0.16 0.12 / 0.16 0.12 / 0.16 0.18 / 0.25 0.4 0.25...0.4 5.2 MPW18-3-D004

- 0.12 / 0.16 0.18 / 0.25 0.18 / 0.25 0.25 / 0.33 0.25 / 0.33 0.63 0.4...0.63 8.2 MPW18-3-C063

0.12 / 0.16 0.25 / 0.33 0.25 / 0.33 0.37 / 0.5 0.37 / 0.5 0.55 / 0.75 1 0.63...1 13 MPW18-3-U001

0.25 / 0.33 0.37 / 0.5 0.75 / 1 0.75 / 1 0.75 / 1 1.1 / 1.5 1.6 1...1.6 20.8 MPW18-3-D016

0.37 / 0.5 0.75 / 1 1.1 / 1.5 1.1 / 1.5 1.1 / 1.5 1.5 / 2 2.5 1.6...2.5 32.5 MPW18-3-D025

0.75 / 1 1.5 / 2 1.5 / 2 1.5 / 2 2.2 / 3 3 / 4 4 2.5...4 52 MPW18-3-U004

1.1 / 1.5 2.2 / 3 3 / 4 3 / 4 3.7 / 5 4 / 5.5 6.3 4...6.3 82 MPW18-3-D063

2.2 / 3 4.5 / 6 5.5 / 7.5 4 / 5.5 5.5 / 7.5 7.5 / 10 10 6.3...10 130 MPW18-3-U010

3.7 / 5 7.5 / 10 9.2 / 12.5 7.5 / 10 9.2 / 12.5 9.2 / 12.5 16 10...16 208 MPW18-3-U016

4.5 / 6 7.5 / 10 9.2 / 12.5 11 / 15 11 / 15 15 / 20 18 12...18 234 MPW18-3-U018

MPW18 Motor Protective Circuit Breaker - Selection Guide

MPW18 MOTOR PROTECTIVE CIRCUIT BREAKER UP TO 18 A (SCREW TERMINAL) -

THERMOMAGNETIC OR MAGNETIC ONLY With overload and short-circuit protection Fixed short-circuit release 13 x lu With phase-failure sensitivity according to IEC 60947-4-1 With temperature compensation For use as main switch (IEC 60947-2) Pushbutton operated

MPW18I MOTOR PROTECTIVE CIRCUIT BREAKER - MAGNETIC - SHORT-CIRCUIT PROTECTION2)

MPW18 MOTOR PROTECTIVE CIRCUIT BREAKER - THERMOMAGNETIC - OVERLOAD AND SHORT-CIRCUIT PROTECTION

Notes: 1) For 50/60 Hz three-phase, 4 poles WEG W22 standard motors. These values are only for reference and may change on the number of poles

and motor design.

2) For overload protection, it is suggested the use of RW27-2D thermal overload relay.

Reference values for selecting protection of three-phase electric motors1)

Rated current

In (A)

Instantaneous magnetic trip

13 x In

Im (A)

Screw terminal

Weight

kg220-240 V

kW/ hp

380-415 V

kW/ hp

440-480 V

kW/ hp

500 V

kW/ hp

550-600 V

kW/ hp

690 V

kW/ hpReference code

- - - - - - 0.16 2.08 MPW18i-3-C016

0.28

- - - - - 0.12 / 0.16 0.25 3.25 MPW18i-3-C025

- - 0.12 / 0.16 0.12 / 0.16 0.12 / 0.16 0.18 / 0.25 0.4 5.2 MPW18i-3-D004

- 0.12 / 0.16 0.18 / 0.25 0.18 / 0.25 0.25 / 0.33 0.25 / 0.33 0.63 8.2 MPW18i-3-C063

0.12 / 0.16 0.25 / 0.33 0.25 / 0.33 0.37 / 0.5 0.37 / 0.5 0.55 / 0.75 1 13 MPW18i-3-U001

0.25 / 0.33 0.37 / 0.5 0.75 / 1 0.75 / 1 0.75 / 1 1.1 / 1.5 1.6 20.8 MPW18i-3-D016

0.37 / 0.5 0.75 / 1 1.1 / 1.5 1.1 / 1.5 1.1 / 1.5 1.5 / 2 2.5 32.5 MPW18i-3-D025

0.75 / 1 1.5 / 2 1.5 / 2 1.5 / 2 2.2 / 3 3 / 4 4 52 MPW18i-3-U004

1.1 / 1.5 2.2 / 3 3 / 4 3 / 4 3.7 / 5 4 / 5.5 6.3 82 MPW18i-3-D063

2.2 / 3 4.5 / 6 5.5 / 7.5 4 / 5.5 5.5 / 7.5 7.5 / 10 10 130 MPW18i-3-U010

3.7 / 5 7.5 / 10 9.2 / 12.5 7.5 / 10 9.2 / 12.5 9.2 / 12.5 16 208 MPW18i-3-U016

4.5 / 6 7.5 / 10 9.2 / 12.5 11 / 15 11 / 15 15 / 20 18 234 MPW18i-3-U018

MPW40 MOTOR PROTECTIVE CIRCUIT BREAKER UP TO 40 A (SCREW TERMINAL) -

THERMOMAGNETIC OR MAGNETIC ONLY With overload and short-circuit protection Fixed short-circuit release 13 x Iu With phase-failure sensitivity according to IEC 60947-4-1 With temperature compensation For use as main switch (IEC 60947-2) Rotary handle operated

Reference values for selecting protection of three-phase electric motors1)

Rated current

In (A)

Instantaneous magnetic trip

13 x In

Im (A)

Screw terminal

Weight

kg220-240 V

kW/ hp

380-415 V

kW/ hp

440-480 V

kW/ hp

500 V

kW/ hp

550-600 V

kW/ hp

690 V

kW/ hpReference code

- - - - - - 0.16 2.08 MPW40i-3-C016

0.36

- - - - - 0.12 / 0.16 0.25 3.25 MPW40i-3-C025

- - 0.12 / 0.16 0.12 / 0.16 0.12 / 0.16 0.18 / 0.25 0.4 5.2 MPW40i-3-D004

- 0.12 / 0.16 0.18 / 0.25 0.18 / 0.25 0.25 / 0.33 0.25 / 0.33 0.63 8.2 MPW40i-3-C063

0.12 / 0.16 0.25 / 0.33 0.25 / 0.33 0.37 / 0.5 0.37 / 0.5 0.55 / 0.75 1 13 MPW40i-3-U001

0.25 / 0.33 0.37 / 0.5 0.75 / 1 0.75 / 1 0.75 / 1 1.1 / 1.5 1.6 20.8 MPW40i-3-D016

0.37 / 0.5 0.75 / 1 1.1 / 1.5 1.1 / 1.5 1.1 / 1.5 1.5 / 2 2.5 32.5 MPW40i-3-D025

0.75 / 1 1.5 / 2 1.5 / 2 1.5 / 2 2.2 / 3 3 / 4 4 52 MPW40i-3-U004

1.1 / 1.5 2.2 / 3 3 / 4 3 / 4 3.7 / 5 4 / 5.5 6.3 82 MPW40i-3-D063

2.2 / 3 4.5 / 6 5.5 / 7.5 4 / 5.5 5.5 / 7.5 7.5 / 10 10 130 MPW40i-3-U010

3.7 / 5 7.5 / 10 9.2 / 12.5 9.2 / 12.5 11 / 15 11 / 15 16 208 MPW40i-3-U016

5.5 / 7.5 9.2 / 12.5 11 / 15 11 / 15 - 15 / 20 20 260 MPW40i-3-U020

- 11 / 15 - 15 / 20 15 / 20 18.5 / 25 25 325 MPW40i-3-U025

9.2 / 12.5 15 / 20 15 / 20 18.5 / 25 22 / 30 22 / 30 32 416 MPW40i-3-U032

11 / 15 18.5 / 25 18.5 / 25 22 / 30 - 37 / 50 40 520 MPW40i-3-U040

Reference values for selecting protection of three-phase electric motors1)

Rated current

In (A)

Setting overload

release

In (A)

Instantaneous

magnetic trip

13 x In

Im (A)

Screw terminal

Weight

kg220-240 V

kW/ hp

380-415 V

kW/ hp

440-480 V

kW/ hp

500 V

kW/ hp

550-600 V

kW/ hp

690 V

kW/ hpReference code

- - - - - - 0.16 0.1...0.16 2.08 MPW40-3-C016

0.36

- - - - - 0.12 / 0.16 0.25 0.16...0.25 3.25 MPW40-3-C025

- - 0.12 / 0.16 0.12 / 0.16 0.12 / 0.16 0.18 / 0.25 0.4 0.25...0.4 5.2 MPW40-3-D004

- 0.12 / 0.16 0.18 / 0.25 0.18 / 0.25 0.25 / 0.33 0.25 / 0.33 0.63 0.4...0.63 8.2 MPW40-3-C063

0.12 / 0.16 0.25 / 0.33 0.25 / 0.33 0.37 / 0.5 0.37 / 0.5 0.55 / 0.75 1 0.63...1 13 MPW40-3-U001

0.25 / 0.33 0.37 / 0.5 0.75 / 1 0.75 / 1 0.75 / 1 1.1 / 1.5 1.6 1...1.6 20.8 MPW40-3-D016

0.37 / 0.5 0.75 / 1 1.1 / 1.5 1.1 / 1.5 1.1 / 1.5 1.5 / 2 2.5 1.6...2.5 32.5 MPW40-3-D025

0.75 / 1 1.5 / 2 1.5 / 2 1.5 / 2 2.2 / 3 3 / 4 4 2.5...4 52 MPW40-3-U004

1.1 / 1.5 2.2 / 3 3 / 4 3 / 4 3.7 / 5 4 / 5.5 6.3 4...6.3 82 MPW40-3-D063

2.2 / 3 4.5 / 6 5.5 / 7.5 4 / 5.5 5.5 / 7.5 7.5 / 10 10 6.3...10 130 MPW40-3-U010

3.7 / 5 7.5 / 10 9.2 / 12.5 9.2 / 12.5 11 / 15 11 / 15 16 10...16 208 MPW40-3-U016

5.5 / 7.5 9.2 / 12.5 11 / 15 11 / 15 - 15 / 20 20 16...20 260 MPW40-3-U020

- 11 / 15 - 15 / 20 15 / 20 18.5 / 25 25 20...25 325 MPW40-3-U025

9.2 / 12.5 15 / 20 15 / 20 18.5 / 25 22 / 30 22 / 30 32 25...32 416 MPW40-3-U032

11 / 15 18.5 / 25 18.5 / 25 22 / 30 - 37 / 50 40 32...40 520 MPW40-3-U040

MPW40 Motor Protective Circuit Breaker - Selection Guide

MPW40 MOTOR PROTECTIVE CIRCUIT BREAKER - THERMOMAGNETIC - OVERLOAD AND SHORT-CIRCUIT PROTECTION

MPW40I MOTOR PROTECTIVE CIRCUIT BREAKER - MAGNETIC - SHORT-CIRCUIT PROTECTION2)

Notes: 1) For 50/60 Hz three-phase, 4 poles WEG W22 standard motors. These values are only for reference and may change on the number of poles

and motor design.

2) For overload protection, it is suggested the use of RW27-2D thermal overload relay.

Page 20: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

36 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 37

MPW40t Motor Protective Circuit Breaker - Selection Guide

MPW40T MOTOR PROTECTIVE CIRCUIT BREAKER UP TO 20 A (SCREW TERMINAL) - THERMOMAGNETIC Motor protective circuit breaker for protection of transformers or motors with high starting current Allows switching and protection against overload and short-circuit of inductive loads Fixed short-circuit release 19 x Iu Breaking capacity 100 kA at 380-415 V ac up to 10 A With phase-failure sensitivity according to IEC 60947-4-1 With temperature compensation Rotary handle operated

Note: 1) For 50/60 Hz three-phase, 4 poles WEG W22 standard motors. These values are only for reference and may change on the number of poles

and motor design.

MPW40T MOTOR PROTECTIVE CIRCUIT BREAKER - THERMOMAGNETIC - OVERLOAD AND SHORT-CIRCUIT PROTECTION

Reference values for selecting protection of three-phase electric motors1)

Rated current

In (A)

Setting overload

release

In (A)

Instantaneous

magnetic trip

13 x In

Im (A)

Screw terminal

Weight

kg220-240 V

kW/ hp

380-415 V

kW/ hp

440-480 V

kW/ hp

500 V

kW/ hp

550-600 V

kW/ hp

690 V

kW/ hpReference code

- - - - - - 0.16 0.1...0.16 3.0 MPW40t-3-C016

0.36

- - - - - 0.12 / 0.16 0.25 0.16...0.25 4.8 MPW40t-3-C025

- - 0.12 / 0.16 0.12 / 0.16 0.12 / 0.16 0.18 / 0.25 0.4 0.25...0.4 7.6 MPW40t-3-D004

- 0.12 / 0.16 0.18 / 0.25 0.18 / 0.25 0.25 / 0.33 0.25 / 0.33 0.63 0.4...0.63 12.0 MPW40t-3-C063

0.12 / 0.16 0.25 / 0.33 0.25 / 0.33 0.37 / 0.5 0.37 / 0.5 0.55 / 0.75 1 0.63...1 19.0 MPW40t-3-U001

0.25 / 0.33 0.37 / 0.5 0.75 / 1 0.75 / 1 0.75 / 1 1.1 / 1.5 1.6 1...1.6 30.4 MPW40t-3-D016

0.37 / 0.5 0.75 / 1 1.1 / 1.5 1.1 / 1.5 1.1 / 1.5 1.5 / 2 2.5 1.6...2.5 47.5 MPW40t-3-D025

0.75 / 1 1.5 / 2 1.5 / 2 1.5 / 2 2.2 / 3 3 / 4 4 2.5...4 76.0 MPW40t-3-U004

1.1 / 1.5 2.2 / 3 3 / 4 3 / 4 3.7/5 4 / 5.5 6.3 4...6.3 119.7 MPW40t-3-D063

2.2 / 3 4.5 / 6 5.5 / 7.5 4 / 5.5 5.5 / 7.5 7.5 / 10 10 6.3...10 190.0 MPW40t-3-U010

3.7 / 5 7.5 / 10 9.2 / 12.5 9.2 / 12.5 11 / 15 11 / 15 16 10...16 304.0 MPW40t-3-U016

5.5 / 7.5 9.2 / 12.5 11 / 15 11 / 15 - 15 / 20 20 16...20 380.0 MPW40t-3-U020

1 - MPW18 motor protective circuit breaker (screw terminal)

2 - Feeder terminal FTBBS

3 - Three-phase busbars BBS

4 - Push-in-lugs PLMP

5 - Side mounted auxiliary contact block ACBS

(screw terminal)

6 - Undervoltage release URMP or shunt release SRMP

(screw terminal)

7 - Front mounted auxiliary contact block ACBF

(screw terminal)

8 - Insulated enclosure

9 - Scale cover SCMP

10 - Trip signalling block TSB

11 - Emergency pushbutton for insulated enclosure

12 - MPW12 motor protective circuit breaker (spring terminal)

13 - Side mounted auxiliary contact block ACBS_S

(spring terminal)

14 - Front mounted auxiliary contact block ACBF_S

(spring terminal)

15 - MPE41 plastic cover for IP66

16 - CWB9...38 contactors

17 - Link module ECCMP-18B38 (MPW18+CWB9...38)

MPW12...MPW18 Motor Protective Circuit Breakers - Overview2

3

6

110

5 7

16

174

12

14

9

13

11

15

8

Page 21: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

38 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 39

MPW40 Motor Protective Circuit Breaker - Overview

1 - MPW40 motor protective circuit breaker (screw terminal)

2 - Feeder terminal FTBBS

3 - Three-phase busbars BBS

4 - Push-in-lugs PLMP

5 - Side mounted auxiliary contact block ACBS (screw terminal)

6 - Undervoltage release URMP or shunt release SRMP

(screw terminal)

7 - Front mounted auxiliary contact block ACBF (screw terminal)

8 - Door coupling rotary handle RMMP

9 - Door coupling rotary handle MRX

10 - Front plate FME55

11 - Standard insulated enclosure MPE55

12 - Large insulated enclosure MLPE55

13 - Trip signalling block TSB

14 - LST25 - Feeder terminal for “Type E” motor starter

according to UL

15 - Current limiter CLT32

16 - Scale cover SCMP

17 - Link module ECCMP-40B38 (MPW40+CWB9...38)

18 - CWB9...38 contactors

3

2

414

1

17

18

5

13

1

7

9

8

10

6

1

11

12

15

16

Motor Protective Circuit-Breaker MPW12_S - Spring Type

MPW12_S - THERMAL-MAGNETIC PROTECTION

TYPE RANGE (A) STOCK CODEPRICE EACH

(ZAR)

MPW12-3-C016S 0.10 - 0.16 12500989 563,00

MPW12-3-C025S 0.16 - 0.25 12500990 563,00

MPW12-3-D004S 0.25 - 0.40 12500992 563,00

MPW12-3-C063S 0.40 - 0.63 12500991 574,00

MPW12-3-U001S 0.63 - 1.0 12500996 581,00

MPW12-3-D016S 1.0 - 1.6 12500993 581,00

MPW12-3-D025S 1.6 - 2.5 12500994 581,00

MPW12-3-U004S 2.5 - 4.0 12500997 581,00

MPW12-3-D063S 4.0 - 6.3 12500995 581,00

MPW12-3-U010S 6.3 - 10 12501028 675,00

MPW12-3-U012S 8 - 12 12501029 675,00

MPW12I_S - MAGNETIC PROTECTION

TYPE RANGE (A) STOCK CODEPRICE EACH

(ZAR)

MPW12i-3-C016S 0.16 12501032 546,00

MPW12i-3-C025S 0.25 12501033 546,00

MPW12i-3-D004S 0.4 12501035 546,00

MPW12i-3-C063S 0.63 12501034 549,00

MPW12i-3-U001S 1 12501059 566,00

MPW12i-3-D016S 1.6 12501036 566,00

MPW12i-3-D025S 2.5 12501037 566,00

MPW12i-3-U004S 4 12501060 566,00

MPW12i-3-D063S 6.3 12501058 566,00

MPW12i-3-U010S 10 12501061 675,00

MPW12i-3-U012S 12 12501062 675,00

wwwww..zestt.coo.zzaa

aaakkkkkkeeerrr MMMMMMPPPPPPWWWWWW1111122222 SSSSSSS SSSSSppprrriiiiinnnggg TTTTTTyyypppeee

The New Generation of WEG Components for Motor Starting and Protection

Page 22: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

40 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 41

Motor Protective Circuit-Breaker MPW18 - Screw Type

MPW18 - THERMAL-MAGNETIC PROTECTION

TYPE RANGE (A) STOCK CODEPRICE EACH

(ZAR)

MPW18-3-C016 0.10 - 0.16 12429311 512,00

MPW18-3-C025 0.16 - 0.25 12429312 512,00

MPW18-3-D004 0.25 - 0.40 12429313 512,00

MPW18-3-C063 0.40 - 0.63 12429315 522,00

MPW18-3-U001 0.63 - 1.0 12429317 528,00

MPW18-3-D016 1.0 - 1.6 12429368 528,00

MPW18-3-D025 1.6 - 2.5 12429369 528,00

MPW18-3-U004 2.5 - 4.0 12429370 528,00

MPW18-3-D063 4.0 - 6.3 12429371 528,00

MPW18-3-U010 6.3 - 10 12429372 614,00

MPW18-3-U016 10 - 16 12429373 614,00

MPW18-3-U018 12 - 18 12429374 706,00

MPW18I - MAGNETIC PROTECTION

TYPE RANGE (A) STOCK CODEPRICE EACH

(ZAR)

MPW18i-3-C016 0.16 12429375 497,00

MPW18i-3-C025 0.25 12429376 497,00

MPW18i-3-D004 0.4 12429377 497,00

MPW18i-3-C063 0.63 12429388 499,00

MPW18i-3-U001 1 12429389 515,00

MPW18i-3-D016 1.6 12429391 515,00

MPW18i-3-D025 2.5 12429392 515,00

MPW18i-3-U004 4 12429393 515,00

MPW18i-3-D063 6.3 12429394 515,00

MPW18i-3-U010 10 12429395 614,00

MPW18i-3-U016 16 12429396 614,00

MPW18i-3-U018 18 12429397 706,00

eeerrr MMMMMMPPPPPPWWWWWW111111888888 SSSSSScccrrreeewww TTTTTyyypppeee

The New Generation of WEG Components for Motor Starting and Protection

Motor Protective Circuit-Breaker MPW40 - Screw Type

MPW40 - THERMAL-MAGNETIC PROTECTION

TYPE RANGE (A) STOCK CODEPRICE EACH

(ZAR)

MPW40-3-C016 0.10 - 0.16 12428084 602,00

MPW40-3-C025 0.16 - 0.25 12428085 602,00

MPW40-3-D004 0.25 - 0.40 12428086 602,00

MPW40-3-C063 0.40 - 0.63 12428087 614,00

MPW40-3-U001 0.63 - 1.0 12429239 621,00

MPW40-3-D016 1.0 - 1.6 12428108 621,00

MPW40-3-D025 1.6 - 2.5 12428110 621,00

MPW40-3-U004 2.5 - 4.0 12428112 621,00

MPW40-3-D063 4.0 - 6.3 12428115 621,00

MPW40-3-U010 6.3 - 10 12428117 722,00

MPW40-3-U016 10 - 16 12428128 722,00

MPW40-3-U020 16 - 20 12428129 778,00

MPW40-3-U025 20 - 25 12428133 921,00

MPW40-3-U032 25 - 32 12428131 990,00

MPW40-3-U040 32 - 40 12382551 1138,00

MPW40I - MAGNETIC PROTECTION

TYPE RANGE (A) STOCK CODEPRICE EACH

(ZAR)

MPW40i-3-C016 0.16 12428137 584,00

MPW40i-3-C025 0.25 12428148 584,00

MPW40i-3-D004 0.4 12428149 584,00

MPW40i-3-C063 0.63 12428150 587,00

MPW40i-3-U001 1 12428153 606,00

MPW40i-3-D016 1.6 12428154 606,00

MPW40i-3-D025 2.5 12428156 606,00

MPW40i-3-U004 4 12428157 606,00

MPW40i-3-D063 6.3 12428178 606,00

MPW40i-3-U010 10 12428179 703,00

MPW40i-3-U016 16 12428180 703,00

MPW40i-3-U020 20 12428181 742,00

MPW40i-3-U025 25 12428182 884,00

MPW40i-3-U032 32 12428183 950,00

MPWi40-3-U040 40 12382552 1092,00

MPW40T - THERMAL-MAGNETIC PROTECTION (IM = 19XI

N)

TYPE RANGE (A) STOCK CODEPRICE EACH

(ZAR)

MPW40t-3-C016 0.10 - 0.16 12428358 843,00

MPW40t-3-C025 0.16 - 0.25 12428359 843,00

MPW40t-3-D004 0.25 - 0.40 12428360 843,00

MPW40t-3-C063 0.40 - 0.63 12428361 860,00

MPW40t-3-U001 0.63 - 1.0 12429308 869,00

MPW40t-3-D016 1.0 - 1.6 12428362 869,00

MPW40t-3-D025 1.6 - 2.5 12428363 869,00

MPW40t-3-U004 2.5 - 4.0 12428364 869,00

MPW40t-3-D063 4.0 - 6.3 12428365 869,00

MPW40t-3-U010 6.3 - 10 12428366 1011,00

MPW40t-3-U016 10 - 16 12428367 1011,00

MPW40t-3-U020 16 - 20 12428378 1089,00

wwwww..zestt.coo.zzaa

rrreeeaaakkkkkeeerrr MMMMMPPPPPWWWWW444400000 SSSSSScccrrreeewww TTTTTyyypppeee

ODE

The New Generation of WEG Components for Motor Starting and Protection

Page 23: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

42 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 43

MPW Motor Protective Circuit Breakers + CLT32 Current Limiter - Rated

Short-Circuit Breaking Capacity (IEC 60947-2)

MPW40+CLT32

Model

Settingoverload release

(A)

380-415 V ac 440 V ac 460-500 V ac 630-690 V ac

Icu Ics Icu Ics Icu Ics Icu Ics

kA kA kA kA kA kA kA kA

MP

W40 +

CLT

32

0.10...0.16

0.16...0.25

0.25...0.4

0.4...0.63

0.63...1

1...1.6

1.6...2.5 50 50

2.5...4 50 50

4...6.3 50 50

6.3...10 100 100 100 100 50 50

10...16 100 100 100 100 100 100 50 50

16...20 100 100 100 100 100 100 50 50

20...25 100 100 100 100 100 100 10 10

25...32 100 100 100 100 100 100 10 10

Note: 1) In cases where Prospective Short-Circuit Current > Icu, backup fuses are required.

Not applicable due to circuit breaker MPW40 already have 100 kA Icu / Ics in related ranges.

MPW Motor Protective Circuit Breakers - Technical Data

Notes: 1) 500 V with plastic enclosure.

2) Reduce current for temperatures exceeding +60 °C (87% to 70 °C).

3) Only available with spring terminal.

Models MPW12 MPW18 MPW12i MPW18i

Maximum rated current Inmax (Ie) 12 A 18 A 12 A 18 A

Number of poles 3

Short-circuit release 13xIemax

13xIemax

Rated operational voltage Ue 690 V1) 690 V1)

Rated frequency 50/60 Hz 50/60 Hz

Rated insulation voltage Ui 690 V 690 V

Rated impulse withstand voltage Uimp 6 kV 6 kV

Use categoryIEC 60947-2 (circuit breaker) A A

IEC 60947-4-1 (motor starter) AC-3 AC-3

Tripping test Yes Yes

Overload protection Yes No

Phase failure sensitivity (IEC 60947-4-1) Yes No

Tripping indication No No

Tripping class (IEC 60947-4-1) 10 -

Maximum operation per hour Operations/hour 15 15

Altitude (m) 2000 2000

Degree of protection (IEC 60529) IP20 IP20

Mechanical life Number of operations 100000 100000

Electrical life Number of operations 100000 100000

Permissible ambient temperature

Transport and storage -50...+80 °C -50...+80 °C

Operation2) -20...+70 °C -20...+70 °C

Temperature compensation (IEC 60947-4-1) -20...+60 °C -

Power dissipation per circuit breaker

Maximum rated currents In

≤10 A 7 W 7 W

≤12 A3) 7 W 7 W

≤16 A 8 W 8 W

≤18 A 7 W 7 W

Resistance to impact (IEC 60068-2-27) 15 g 15 g

Standards

IEC 60947-1 Yes

IEC 60947-2 Yes

IEC 60947-4-1 Yes

Connection

Type of terminal SpringScrews

Phillips (Nº 2)Spring

ScrewsPhillips (Nº 2)

Tightening torqueN.m - 1.2...1.7 - 1.2...1.7

lb.in - 11...16 - 11...16

Dimensions

Width (mm) 45 45 45 45

Height (mm) 100 90 100 90

Depth (mm) 77 77 77 77

Page 24: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

44 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 45

MPW Motor Protective Circuit Breakers - Technical Data

Altitude

(above sea level) - h

Rated operational voltage

Ue

Current correction factor

Iu

h ≤2000 m 690 V 1 x In

2000< h ≤3000 m 550 V 0.96 x In

3000< h ≤4000 m 480 V 0.93 x In

4000< h ≤5000 m 420 V 0.90 x In

ALTITUDE - CORRECTION FACTOR

The MPW motor protective circuit breakers do not undergo

any change to their specified performance when applied at

an altitude of up to 2000 meters above sea level.

However, as the altitude increases, the atmospheric

properties vary in terms of dielectric rigidness and pressure.

Therefore, current and voltage correction factors must be

applied for altitudes exceeding 2000 meters, as shown in the

following table:

Notes: 1) 500 V with plastic enclosure.

2) Reduce current for temperatures exceeding +60 °C (87% to 70 °C).

3) Only available with spring terminal.

Models MPW40 MPW40i MPW40t

Maximum rated current Inmax (Ie) 40 A 20 A

Number of poles 3

Short-circuit release 13xIemax

19 x Iemax

Rated operational voltage Ue 690 V1)

Rated frequency 50/60 Hz

Rated insulation voltage Ui 690 V

Rated impulse withstand voltage Uimp 6 kV

Use categoryIEC 60947-2 (circuit breaker) A

IEC 60947-4-1 (motor starter) AC-3

Tripping test Yes

Overload protection Yes No Yes

Phase failure sensitivity (IEC 60947-4-1) Yes No Yes

Tripping indication Yes No Yes

Tripping class (IEC 60947-4-1) 10 - 10

Maximum operation per hour Operations/hour 15

Altitude (m) 2000

Degree of protection (IEC 60529) IP20

Mechanical life Number of operations 100000

Electrical life Number of operations 100000

Permissible ambient temperature

Transport and storage -50...+80 °C

Operation2) -20...+70 °C

Temperature compensation (IEC 60947-4-1) -20...+60 °C - -

Power dissipation per circuit breaker

Maximum rated currents In

≤10 A 7 W

≤16 A 8 W

≤20 A 9 W

≤25 A 10 W

≤32 A 15 W

≤40 A 15 W

Resistance to impact (IEC 60068-2-27) 15 g

Standards

IEC 60947-1 Yes

IEC 60947-2 Yes

IEC 60947-4-1 Yes

Connection

Type of terminal Screws phillips (Nº 2)

Tightening torqueN.m 2...2.5

lb.in 18...22

Dimensions

Width (mm) 45

Height (mm) 97

Depth (mm) 98

SHUNT RELEASE - SRMP

Mounting Configurations for MPW Motor Protective Circuit Breaker

Reference codes SRMP

For use with MPW12...40

Rated insulation voltage Ui 690 V

Operating voltage

(guarantee cir. breaker switch OFF)0.7...1.1 x Ue

Energization consumption 20.2 VA / 13 W

Max. opening time 20 ms

Type of terminal Flat

Type of screws Phillips (Nº 2)

Tightening torque 1...1.5 N.m (7...10 lb.in)

Rigid cable 1 or 2 x (0.5...1.5 mm2)

1 or 2 x (0.75...2.5 mm2)

1 or 2 x (18...14 AWG)Flexible cable

Backup fuses gL/gG 10 A

Live or grounded parts distance to the circuit breaker

Model Ue

Minimum distance between the circuit

breaker and live or grounded parts (mm)

B C A

MPW12...18 Up to 690 V 20 75 9

MPW40Up to 500 V 30 95 9

Up to 690 V 50 95 30

The motor protective circuit breaker can be mounted in any position, but according to IEC 60447 standard, the “On - I” indicator must be to the right, or up.

The MPW12...40 can also be used for operating continuous

current loads. For such operation it is necessary to connect

2 or 3 poles in series.

See recommended circuits and their voltage limits in the

table on the right.

Short-circuit breaking capacity Icu = 10 kA for all

configurations.

Circuits Max. V dc Notes

150 V dcSystem not grounded;

2 pole series connected.

300 V dcSystem grounded;

2 pole series connected.

450 V dcSystem grounded;

3 pole series connected.

DC Operation

MPW Motor Protective Circuit Breakers - Technical Data

Page 25: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

46 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 47

MPW Motor Protective Circuit Breakers - Rated Short-Circuit Breaking

Capacity (IEC 60947-2)¹)

MPW12...40

Notes: 1) In cases where Prospective Short-Circuit Current >Icu, backup fuses are required.

2) Only available with spring terminals.

3) Only available with screw terminals.

Models

Settingoverload release

(A)

220-230 V ac 380-415 V ac 440 V ac 460-500 V ac 630-690 V ac

Icu Ics Icu Ics Icu Ics Icu Ics Icu Ics

kA kA kA kA kA kA kA kA kA kA

MP

W12...1

8

0.10...0.16 100 100 100 100 100 100 100 100 10 10

0.16...0.25 100 100 100 100 100 100 100 100 10 10

0.25...0.4 100 100 100 100 100 100 100 100 10 10

0.4...0.63 100 100 100 100 100 100 100 100 10 10

0.63...1 100 100 100 100 100 100 100 100 10 10

1...1.6 100 100 100 100 100 100 100 100 10 10

1.6...2.5 100 100 100 100 100 100 100 100 8 8

2.5...4 100 100 100 100 100 100 100 100 8 8

4...6.3 100 100 100 100 100 100 100 100 8 8

6.3...10 100 100 50 10 50 10 10 10 5 5

8...122) 100 100 10 10 10 10 10 8 4 3

10...163) 100 100 10 10 10 10 10 8 4 3

12...18 100 100 10 10 10 10 10 8 4 3

MP

W40

0.10...0.16 100 100 100 100 100 100 100 100 100 100

0.16...0.25 100 100 100 100 100 100 100 100 100 100

0.25...0.4 100 100 100 100 100 100 100 100 100 100

0.4...0.63 100 100 100 100 100 100 100 100 100 100

0.63...1 100 100 100 100 100 100 100 100 100 100

1...1.6 100 100 100 100 100 100 100 100 100 100

1.6...2.5 100 100 100 100 100 100 100 100 8 8

2.5...4 100 100 100 100 100 100 100 100 8 8

4...6.3 100 100 100 100 100 100 100 100 8 8

6.3...10 100 100 100 100 50 25 42 21 8 8

10...16 100 100 50 25 50 15 10 8 5 5

16...20 100 100 50 25 50 15 10 8 5 5

20...25 100 100 50 25 50 15 10 8 5 5

25...32 100 100 50 25 25 15 10 8 5 5

32...40 100 100 30 15 20 10 10 5 5 2

Accessories for MPW12, MPW18 and MPW40

Motor Circuit-Breakers

DESCRIPTION CONNECTION TYPE TO USE WITH TYPESTOCK

CODE

PRICE EACH

(ZAR)

Front mountable auxiliary contact block (1NO + 1NC)Spring MPW12_S ACBF-11S 12463910 93,00

Screw MPW18, MPW40 ACBF-11 12463886 85,00

Side mountable auxiliary contact block (1NO + 1NC) Spring MPW12_S ACBS-11S 12463908 99,00

Screw MPW18, MPW40 ACBS-11 12463909 90,00

Side mountable auxiliary contact block (2NO) Spring MPW12_S ACBS-20S 12463913 99,00

Screw MPW18, MPW40 ACBS-20 12463912 90,00

Side mountable auxiliary contact block (2NC) Spring MPW12_S ACBS-02S 12463915 99,00

Screw MPW18, MPW40 ACBS-02 12463914 90,00

Trip signalling block Screw MPW40 TSB 12463916 298,00

Current limiter 1) Screw MPW18, MPW40 CLT32 12462918 471,00

45 mm busbar adapter

- MPW18, MPW40 BBS45-2 10045352 155,00

- MPW18, MPW40 BBS45-3 10045351 177,00

- MPW18, MPW40 BBS45-4 10045350 177,00

- MPW18, MPW40 BBS45-5 10045349 236,00

54 mm busbar adapter

- MPW18, MPW40 BBS54-2 10409844 162,00

- MPW18, MPW40 BBS54-3 10409845 186,00

- MPW18, MPW40 BBS54-4 10409846 195,00

- MPW18, MPW40 BBS54-5 10409847 284,00

Feeder terminal Connector ext. 3Ø - MPW18, MPW40 FTBBS 10409848 118,00

Starter type “E” - MPW18, MPW40 LST25 10047102 298,00

BLOCKS, BUSBARS ADAPTERS AND LINKS

Note : 1) For use with MPW40 up to 32 A.

Quantity per packing: 3 units.

UNDERVOLTAGE RELEASE - SCREW TYPE

RATED VOLTAGE TO USE WITH TYPESTOCK

CODE

PRICE EACH

(ZAR)

110 V 50 Hz / 120 V 60 Hz

MPW18

MPW40

URMP V18 12463874 261,00

110-115 V 50 Hz / 127 V 60 Hz URMP V19 12463875 261,00

180 V 50 Hz / 208 V 60 Hz URMP V23 12463876 261,00

190 V 50 Hz / 220 V 60 Hz URMP V26 12463877 261,00

220 V 50 Hz / 255 V 60 Hz URMP V32 12463878 261,00

208 V 50 Hz / 240 V 60 Hz URMP V30 12463879 261,00

230-240 V 50 Hz / 277 V 60 Hz URMP V37 12463880 261,00

325 V 50 Hz / 380 V 60 Hz URMP V41 12463881 261,00

380 V 50 Hz / 440 V 60 Hz URMP V42 12463882 261,00

400-415 V 50 Hz / 480 V 60 Hz URMP V47 12463883 261,00

24 V 50/60 Hz URMP D02 12463884 261,00

220 V 50/60 Hz URMP D23 12463885 261,00

wwwww..zestt.coo.zzaa

MMMMMMMPPPPPPPWWWWWWW1111118888888 aaannndddddd MMMMMMPPPPPPWWWWWWW444444000000

The New Generation of WEG Components for Motor Starting and Protection

Page 26: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

48 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 49

REMOTE SHUNT RELEASE - SCREW TYPE

RATED VOLTAGE TO USE WITH TYPE STOCK CODEPRICE EACH

(ZAR)

20-24 V 50/60 Hz

MPW18

MPW40

SRMP D51 12463869 261,00

40-48 V 50/60 Hz SRMP D54 12463870 261,00

100-127 V 50/60 Hz SRMP D59 12463871 261,00

200-240 V 50/60 Hz SRMP D65 12463872 261,00

365-440 V 50/60 Hz SRMP D69 12463873 261,00

DOOR-COUPLING ROTARY HANDLE

DESCRIPTION TO USE WITH TYPE HANDLE COLOUR STOCK CODEPRICE EACH

(ZAR)

Door-coupling rotary handle MPW40

RMMP-130 Black 10185921 339,00

RMMP-130E Red 10185923 381,00

RMMP-330 Black 10185922 396,00

RMMP-330E Red 10185924 439,00

MRX-130 Black 11051796 366,00

MRX-130E Red 10857691 412,00

MRX-330 Black 11051797 428,00

MRX-330E Red 10857692 474,00

INSULATED ENCLOSURE - IP55

DESCRIPTION TO USE WITH TYPEPROTECTION

DEGREEHANDLE COLOUR

STOCK

CODE

PRICE EACH

(ZAR)

No lugs

(M25) - knockout

MPW18MPE41 IP41 - 11146211 124,00

MPE66 IP66 - 11065621 172,00

MPW40MPE55 IP55 Black 10211804 149,00

MPE55-E IP55 Red 10211805 154,00

With ground terminals

(M25) - knockout

MPW18MPE41G IP41 - 10831702 132,00

MPE66G IP66 - 10831703 180,00

MPW40MPE55G IP55 Black 10649171 158,00

MPE55G-E IP55 Red 10186289 162,00

With ground and neutral lugs

(PG16) - knockout

MPW18MPE41GN IP41 - 11146214 140,00

MPE66GN IP66 - 11065622 188,00

MPW40MPE55GN IP55 Black 10211953 165,00

MPE55GN-E IP55 Red 10211954 169,00

No lugs

(PG16) - knockout

MPW18PE41 IP41 - 10831536 124,00

PE66 IP66 - 10831535 172,00

MPW40PE55 IP55 Black 10185915 149,00

PE55-E IP55 Red 10185916 154,00

With ground terminals

(PG16) - knockout

MPW18PE41G IP41 - 10831606 132,00

PE66G IP66 - 10831643 180,00

MPW40PE55G IP55 Black 10185917 158,00

PE55G-E IP55 Red 10185918 162,00

With ground and neutral lugs

(PG16) - knockout

MPW18PE41GN IP41 - 10831607 140,00

PE66GN IP66 - 10831700 188,00

MPW40PE55GN IP55 Black 10185919 165,00

PE55GN-E IP55 Red 10185920 169,00

Increases protection degree

of MPE41 to IP66MPW18 KIT66PE IP66 - 10853867 49,00

E-STOP - twist to releaseMPW18

FESTPE - Red 11659180 155,00

E-STOP - key to release FESYPE - Red 11659178 Upon Request

Accessories for MPW12, MPW18 and MPW40

Motor Circuit-Breakers

PPPPPPPPPWWWWWWWWW1111111188888888 aaannndddddddd MMMMMMMPPPPPPPPWWWWWWWW4444444000000

The New Generation of WEG Components for Motor Starting and Protection

INSULATED ENCLOSURE SIZE “L” - IP55

DESCRIPTION TO USE WITH TYPE HANDLE COLOUR STOCK CODEPRICE EACH

(ZAR)

No lugs (M25) - knockout MPW40LPE55 Black 10212325 232,00

LPE55-E Red 10212326 239,00

With ground terminals

(M25) - knockout MPW40

LPE55G Black 10211362 249,00

LPE55G-E Red 10211363 256,00

With ground and neutral lugs

(M25) - knockout MPW40

LPE55GN Black 10211955 256,00

LPE55GN-E Red 10211956 263,00

Note: Allows the installation of undervoltage or remote shunt release (SRMP or URMP).

FRONTAL PLATE

DESCRIPTION TO USE WITH TYPE HANDLE COLOURSTOCK

CODE

PRICE EACH

(ZAR)

IP55MPW40

FME55 Black 10186425 487,00

IP55 FME55E Red 10186426 502,00

PUSH-IN-LUGS, CIRCUIT-BREAKER - CONTACTOR LINK MODULE AND SCALE COVER

DESCRIPTION TO USE WITH TYPESTOCK

CODE

PRICE EACH

(ZAR)

Push-in-lugs 1) MPW18, MPW40 PLMP 10185925 3,00

Link module for contactor CWB9...38 (AC coil) MPW18 ECCMP-18B38 12462672 71,00

Link module for contactor CWB9...38 (AC coil) MPW40 ECCMP-40B38 12462673 71,00

Link module for contactor CWB9...38 (DC coil) MPW40 ECCMP-40B38DC 12462674 71,00

Link module for contactor CWM9...25 MPW40 ECCMP-25 10409822 71,00

Link module for contactor CWM32 MPW40 ECCMP-32 10075736 71,00

Scale cover MPW18, MPW40 SCMP 10186290 9,00

Protection cover for BBS - CSD 10073627 58,00

Mounting adapter for direct-on-line starters MPW18, MPW40 MA45DOL MPW 10073629 246,00

Mounting adapter for reversing starters MPW18, MPW40 MA90RVS MPW 10073628 312,00

Mounting adapter for star-delta starters MPW18, MPW40 MA90SDS MPW 10073630 520,00

Connector for PCB - main contacts MPW18 CIC16 11647168 Upon request

Connector for PCB - mains and aux. contacts MPW18 CIC16A 11647117 Upon request

Note: 1) Quantity per packing: 2 units.

Accessories for MPW12, MPW18 and MPW40

Motor Circuit-Breakers

wwwww..zestt.coo.zzaa

MMMMMMMPPPPPPPWWWWWWW11111118888888 aaannndddddd MMMMMMMPPPPPPPWWWWWW4444400000

The New Generation of WEG Components for Motor Starting and Protection

Page 27: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

50 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 51

Contactors

Selection Guide

Reference 3 poles CWC07 CWC09 CWC012 CWC016 CWC025

Rated operational power 1)

220/230 V ac kW/ hp 1.5 / 2 2.2 / 3 3 / 4 4 / 5 5.5 / 7.5

380 V ac kW/ hp 3 / 4 4 / 5 5.5 / 7.5 7.5 / 10 11 / 15

400/415 V ac kW/ hp 3 / 4 4 / 5 5.5 / 7.5 7.5 / 10 11 / 15

440 V ac kW/ hp 3.7 / 5 4.5 / 6 5.5 / 7.5 7.5 / 10 11 / 15

500 V ac kW/ hp 3.7 / 5 4.5 / 6 5.5 / 7.5 7.5 / 10 11 / 15

660/690 V ac kW/ hp 3 / 4 4 / 5 5.5 / 7.5 7.5 / 10 11 / 15

Rated operational current I

e AC-3 (U

e ≤ 440 V) A

7 9 12 16 22

Conventional thermal current I

th = I

e AC-1 A

18 20 22 22 32

Rated operational current I

e AC-4 (U

e ≤ 440 V) A

2.8 3.5 4.5 5 9

Overload relay A

0.28. . .0.4

0.4. . .0.63

0.56. . .0.8

0.8. . .1.2

1.2. . .1.8

1.8. . .2.8

2.8. . .4

4. . .6.3

5.6. . .8

7. . .10

8. . .12.5

10. . .15

11. . .17

7…10

8…12.5

10…15

11…17

15…23

22…32

Auxiliary contact blocks

BFC0-20 (2NO)BFC0-22 (2NO + 2NC)BFC0-11 (1NO + 1NC)BFC0-04 (4NC)BFC0-02 (2NC)BFC0-31 (2NO + 1NC)BFC0-40 (4NO)BFC0-13 (1NO + 3NC)

BFC025-11 (1NO + 1NC) BFC025-20 (2NO)BFC025-02 (2NC)BFC025-22 (2NO + 2NC)

Mechanical interlock BICO _

TimerON-Delay (TECO)

OFF-Delay (TDCO)

Star-Delta (TETCO)

Surge suppressor

Notes: 1) For 50/60 Hz three-phase, 4 poles WEG standard motors. These values are only for reference and may change on the number of poles and motor design;

2) Electrical and mechanical interlock;

3) Only available for CWC07 to 16.

RW17-2DRW17-1D 17-2D

Varistor block:

VRC0-1 E01 12-48 V 50/60 Hz / 12-60 V dc

VRC0-2 E34 50-127 V 50/60 Hz / 60-180 V dc

VRC0-3 E50 130-250 V 50/60 Hz / 180-300 V dc

VRC0-4 E41 277-380 V 50/60 Hz / 300-510 V dc

VRC0-5 D73 400-510 V 50/60 Hz

Diode block 3):

DIC0-1 C33 12-600 V dc

DIZC0 C26 12...250 V dc

RC block:

RCC0-1 D49 12-24 V 50/60 Hz

RCC0-2 D53 24-48 V 50/60 Hz

RCC0-3 D55 50-127 V 50/60 Hz

RCC0-4 D63 130-250 V 50/60 Hz

RCC0-5 D84 275-380 V 50/60 Hz

RCC0-6 D73 400-510 V 50/60 Hz

RCAC0 D87 180...230 V 50/60 Hz

CWM9 CWM12 CWM18 CWM25 CWM32 CWM40 CWM50 CWM65 CWM80 CWM95 CWM105

2.2 / 3 3 / 4 4.5 / 6 5.5 / 7.5 9.2 / 12.5 11 / 15 15 / 20 18.5 / 25 22 / 30 22 / 30 30 / 40

4 / 5 5.5 / 7.5 7.5 / 10 11 / 15 15 / 20 18.5 / 25 22 / 30 30 / 40 37 / 50 45 / 60 55 / 75

4 / 5 5.5 / 7.5 7.5 / 10 11 / 15 15 / 20 18.5 / 25 22 / 30 30 / 40 45 / 60 55 / 75 55 / 75

4.5 / 6 5.5 / 7.5 9.2 / 12.5 11 / 15 15 / 20 22 / 30 30 / 40 37 / 50 45 / 60 55 / 75 55 / 75

4.5 / 6 5.5 / 7.5 9.2 / 12.5 11 / 15 15 / 20 22 / 30 30 / 40 37 / 50 45 / 60 55 / 75 55 / 75

5.5 / 7.5 7.5 / 10 11 / 15 11 / 15 18.5 / 25 22 / 30 30 / 40 37 / 50 45 / 60 55 / 75 55 / 75

9 12 18 25 32 40 50 65 80 95 105

25 25 32 45 60 60 90 110 110 140 140

5 7 8 12 16 18.5 23 30 37 44 50

0.28. . .0.4

0.4. . .0.63

0.56. . .0.8

0.8. . .1.2

1.2. . .1.8

1.8. . .2.8

2.8. . .4

4. . .6.3

5.6. . .8

7. . .10

8. . .12.5

10. . .15

11. . .17

15…23

22…32

25...40

32...50

25...40

40...57

50...63

57...70

63...80

63...80

75...97

90...112

BCXMF10 (1NO)

BCXMF01 (1NC)

BCXMFA10 (1NC)

BCXMFR01 (1NC)

BCXML 11 (1NO + 1NC)

BCXML 20 (2NO)

BCXMRL 11 (1NO + 1NC)

BCXMRL 20 (2NO)

BLIM9-105

BLIM.02 2)

_

RC block:

BAMRC4 D53 24-48 V 50/60 Hz

BAMRC5 D55 50-127 V 50/60 Hz

BAMRC6 D63 130-250 V 50/60 Hz

Diode block:

BAMDI10 C33 12-600 V dc

Varistor block:

BAMV1 D68 270-380 V 50/60 Hz

BAMV2 D73 400-510 V 50/60 Hz

RC block:

BAMRC7 D53 24-48 V 50/60 Hz

BAMRC8 D55 50-127 V 50/60 Hz

BAMRC9 D63 130-250 V 50/60 Hz

Varistor block:

BAMV1 D68 270-380 V 50/60 Hz

BAMV2 D73 400-510 V 50/60 Hz

2...50

RW67-1D RW117-1DRW67-2DRW27-1D

Page 28: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

52 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 53

Reference 3 Poles CWM112 1) CWM150 3) CWM180 1) CWM250 1) CWM300 3)

Rated operational power 4)

220/230 V ac kW/ hp 30 / 40 45 / 60 55 / 75 75 / 100 90 / 125

380 V ac kW/ hp 55 / 75 75 / 100 90 / 125 132 / 175 150 / 200

400/415 V ac kW/ hp 55 / 75 75 / 100 90 / 125 132 / 175 160 / 220

440 V ac kW/ hp 55 / 75 90 / 125 110 / 150 150 / 200 185 / 250

500 V ac kW/ hp 55 / 75 90 / 125 110 / 150 160 / 220 200 / 270

660/690 V ac kW/ hp 75 / 100 110 / 150 110 / 150 160 / 220 200 / 270

Rated operational

current Ie AC-3 (Ue ≤ 440 V) A

112 150 180 250 300

Conventional thermal

current Ith = I

e, AC-1 A

180 225 225 350 410

Rated operational

current Ie AC-4 (U

e ≤ 440 V) A

63 69 73 110 145

Overload relays A

Auxiliary contact blocks

Mechanical interlock

Surge suppressor 2)

RC block:

BAMRC13 D53 24-48 V 50/60 Hz

BAMRC14 D56 50-250 V 50/60 Hz

Varistor block:

BAMV3 D68 270-380 V 50/60 Hz

BAMV4 D73 400-510 V 50/60 Hz

_

RC block:

BAMRC13 D53 24-48 V 50/60 Hz

BAMRC14 D56 50-250 V 50/60 Hz

Varistor block:

BAMV3 D68 270-380 V 50/60 Hz

BAMV4 D73 400-510 V 50/60 Hz

_

Notes: 1) Available with AC coil or with electronic module - AC/DC;

2) Only applicable for contactors without electronic module;

3) Only with electronic module;

4) For 50/60 Hz three-phase, 4 poles WEG standard motors. These values are only for reference and may change on the number of poles and motor design.

RW317-1DRW117-2D

BCXML11 (1NO + 1NC)

BCXML20 (2NO)

BCXMRL11 (1NO + 1NC)

BCXMRL20 (2NO)

BLIM112-

300

100...150

140...215

200...310

275...420

63...80

75...97

90...112

CWM400 3) CWM500 3) CWM630 3) CWM800 3)

110 / 150 150 / 200 185 / 250 220 / 300

220 / 300 260 / 350 330 / 450 440 / 600

220 / 300 260 / 350 330 / 450 440 / 600

220 / 300 300 / 400 330 / 450 440 / 600

220 / 300 260 / 350 330 / 450 500 / 700

260 / 350 370 / 500 330 / 450 500 / 700

400 500 630 800

450 580 660 900

300 350 400 630

400…600

560…840

BCXML11 CWM800 (1NO + 1NC)

BCXMRL11 CWM800 (1NO + 1NC) 4)

BLIM CWM400

BLIM CWM800

-

RW407-1D

Page 29: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

54 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 55

Compact Contactors

The CWC0 compact contactors are offered as a complete solution for switching and controlling motors.

MAIN FEATURES Contactors with screw terminals for AC-3 operation up to 22 A Contactors with spring terminals for AC-3 operation up to 12 A (CE Certification only) Compact contactors up to 16 A with the same size both for AC and DC coils Rated insulation voltage 690 V Significantly less consumption and heat dissipation, allowing PLC direct

operation without coupling relay Wide range of accessories, compact and fast mounting Designed according to the standards IEC/EN 60947, DIN VDE 0660 (102) and

UL508 Power and auxiliary contacts comply with IEC 60947-4-1 (mirror contacts) and IEC

60947-5-1 (mechanically linked contacts) Mounting through screws or DIN rail 35 mm (EN 50022) Terminals easy to access and protected against accidental touch (IP20)

CERTIFICATIONS

and controlling

The New Generation of WEG Components for Motor Starting and Protection

8

7

2

4

1

2

3

4

5

6

7

8

9

- Compact contactors CWC07...16 (screw terminal)

- Compact contactors CWC07...12_S (spring terminal)

- Compact contactor CWC025 (screw terminal)

- Auxiliary contact block BFC0 - front mounting

- Mechanical interlock block BIC0 or latch block RMC0

- Easy connection busbars

- Surge supressor blocks RCC0 (RC), VRC0 (varistor), DIC0 (diode), RCAC0 (RC), DIZC0 (diode+zener)

- Electronic timers TEC0, TDC0 and TETC0

- Block module for printed circuit board CIC0

8

7

4

3

9

7

4

1

8

7

4

7

5

1

6

4

4

4

7777777777777777777777777777777777777777777777777777777777777777777

Overview

wwwww..zestt.coo.zzaaestt.The New Generation of WEG Components

for Motor Starting and Protection

Page 30: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

56 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 57

3-Pole Compact Contactors

COMPACT CONTACTORS CWC0 - SCREW TYPE

TYPERATED POWER

AC-3 /400 V (kW)

RATED CURRENT

AUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC-1D02 (24 V) D13 (110 V) D24 (230 V) D34 (400 V)

CWC07-10-30 3 7 18

1NO 12487293 12487364 12487288 12679737 266,00

CWC07-01-30 1NC 12487294 12487314 12487297 12679758 266,00

CWC09-10-30 4 9 20

1NO 12487235 12487382 12487295 12679759 287,00

CWC09-01-30 1NC 12487310 12679730 12487343 12679760 287,00

CWC012-10-30 5.5 12 22

1NO 12487313 12679731 12487234 12679761 296,00

CWC012-01-30 1NC 12487233 12679732 12487361 12679762 296,00

CWC016-10-30 7.5 16 22

1NO 12487346 12679734 12487340 12679763 307,00

CWC016-01-30 1NC 12487344 12679735 12487389 12679764 307,00

CWC025-00-30 11 22 32 - 12487309 12679736 12487342 12679765 388,00

COMPACT CONTACTORS CWC0 - 7 TO 22 A - AC COIL

TYPERATED POWER

AC-3 /400 V (kW)

RATED CURRENT

AUX. CONTACT

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC-1C03 (24 VDC) C12 (110 VDC) C15 (220 VDC)

CWC07-10-30 3 7 18

1NO 12486689 12486698 Upon request 1) 333,00

CWC07-01-30 1NC 12486690 12486699 Upon request 1) 333,00

CWC09-10-30 3.7 9 20

1NO 12486691 12486700 Upon request 1) 368,00

CWC09-01-30 1NC 12486692 12486702 Upon request 1) 368,00

CWC012-10-30 5.5 12 22

1NO 12486694 12486703 Upon request 1) 370,00

CWC012-01-30 1NC 12486695 12486704 Upon request 1) 370,00

CWC016-10-30 7.5 16 22

1NO 12486696 12486705 Upon request 1) 394,00

CWC016-01-30 1NC 12486697 12486706 Upon request 1) 394,00

COMPACT CONTACTORS CWC0 - 7 TO 16 A - DC COIL - STANDARD CONSUMPTION

Note : 1) Upon Request. - Smart code of the rated voltage.

The New Generation of WEG Components for Motor Starting and Protection

3-Pole Compact Contactors

COMPACT CONTACTORS CWC0 - SCREW TYPE

TYPE RATED POWER

AC-3 /400 V (kW)

RATED CURRENT

AUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC-1R03 (24 VDC) R12 (110 VDC) R15 (220 VDC)

CWC07-10-30 3 7 18

1NO Upon request 2) Upon request 2) Upon request 2) Upon request

CWC07-01-30 1NC Upon request 2) Upon request 2) Upon request 2) Upon request

CWC09-10-30 4 9 20

1NO Upon request 2) Upon request 2) Upon request 2) Upon request

CWC09-01-30 1NC Upon request 2) Upon request 2) Upon request 2) Upon request

CWC012-10-30 5.5 12 22

1NO Upon request 2) Upon request 2) Upon request 2) Upon request

CWC012-01-30 1NC Upon request 2) Upon request 2) Upon request 2) Upon request

CWC016-10-30 7.5 16 22

1NO Upon request 2) Upon request 2) Upon request 2) Upon request

CWC016-01-30 1NC Upon request 2) Upon request 2) Upon request 2) Upon request

COMPACT CONTACTORS CWC0 - 7 TO 16 A - 0.75 X UC DC COIL - STANDARD CONSUMPTION

TYPERATED POWER

AC-3 /400 V (kW)

RATED CURRENT

AUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC-1L03 (24 VDC) L12 (110 VDC) L15 (220 V DC/CC)

CWC07-10-30 3 7 18

1NO 12486719 Upon request 2) Upon request 2) 339,00

CWC07-01-30 1NC 12486720 Upon request 2) Upon request 2) 339,00

CWC09-10-30 4 9 20

1NO 12486722 Upon request 2) Upon request 2) 376,00

CWC09-01-30 1NC 12486723 Upon request 2) Upon request 2) 376,00

CWC012-10-30 5.5 12 22

1NO 12486725 Upon request 2) Upon request 2) 377,00

CWC012-01-30 1NC 12486726 Upon request 2) Upon request 2) 377,00

CWC016-10-30 7.5 16 22

1NO 12486727 Upon request 2) Upon request 2) 402,00

CWC016-01-30 1NC 12486729 Upon request 2) Upon request 2) 402,00

COMPACT CONTACTORS CWC0 - 7 TO 16 A - DC COIL - LOW CONSUMPTION 1)

Note : 1) Auxiliary block front mounting available at a maximum of 2 contacts.

2) Upon Request.

- Smart code of the rated voltage.

wwwww..zestt.coo.zzaa

ttttttttoooorrrrssss

The New Generation of WEG Components for Motor Starting and Protection

Page 31: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

58 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 59

3-Pole Compact Contactors

COMPACT CONTACTORS CWCI0 - SCREW TYPE

TYPE AUX. CONTACTS

RATED CURRENT

Ie

AC-3

STOCK CODEPRICE EACH

(ZAR)D02 (24 V) D13 (110 V) D24 (230 V) D34 (400 V)

CWCI07-10-30 1NO 7 Upon request 1) Upon request 1) 12680851 Upon request 1) 598,00

CWCI07-01-30 1NC 7 Upon request 1) Upon request 1) 12680852 Upon request 1) 641,00

CWCI09-10-30 1NO 9 Upon request 1) Upon request 1) 12680853 Upon request 1) 641,00

CWCI09-01-30 1NC 9 Upon request 1) Upon request 1) 12680854 Upon request 1) 658,00

CWCI012-10-30 1NO 12 Upon request 1) Upon request 1) 12680856 Upon request 1) 658,00

CWCI012-01-30 1NC 12 Upon request 1) Upon request 1) 12680857 Upon request 1) 681,00

CWCI016-10-30 1NO 16 Upon request 1) Upon request 1) 12680868 Upon request 1) 681,00

CWCI016-01-30 1NC 16 Upon request 1) Upon request 1) 12680869 Upon request 1) 681,00

TYPE AUX. CONTACT

RATED CURRENT

Ie

AC-3

STOCK CODEPRICE EACH

(ZAR)C03 (24 VDC) C12 (110 VDC) C15 (220 VDC)

CWCI07-10-30 1NO 7 12680889 Upon request 1) Upon request 1) 745,00

CWCI07-01-30 1NC 7 12680890 Upon request 1) Upon request 1) 745,00

CWCI09-10-30 1NO 9 12680891 Upon request 1) Upon request 1) 817,00

CWCI09-01-30 1NC 9 12680892 Upon request 1) Upon request 1) 817,00

CWCI012-10-30 1NO 12 12680893 Upon request 1) Upon request 1) 821,00

CWCI012-01-30 1NC 12 12680894 Upon request 1) Upon request 1) 821,00

CWCI016-10-30 1NO 16 12680895 Upon request 1) Upon request 1) 870,00

CWCI016-01-30 1NC 16 12680896 Upon request 1) Upon request 1) 870,00

COMPACT CONTACTORS CWCI0 WITH MECHANICAL INTERLOCK - 7 TO 16 A - AC COIL

COMPACT CONTACTORS CWCI0 WITH MECHANICAL INTERLOCK - 7 TO 16 A - DC COIL

Note : 1) Upon Request.

Auxiliary block front mounting available at a maximum of 2 contacts.

- Smart code of the rated voltage.

The New Generation of WEG Components for Motor Starting and Protection

3-Pole Compact Contactors

COMPACT CONTACTORS CWCH0 - SCREW TYPE

COMPACT CONTACTORS WITH LATCH BLOCK CWCH0 - 7 TO 16 A - AC COIL

COMPACT CONTACTORS WITH LATCH BLOCK CWCH0 - 7 TO 16 A - DC COIL

Note : 1) Upon Request..

Auxiliary block front mounting available at a maximum of 2 contacts.

- Smart code of the rated voltage.

TYPE

RATED CURRENT

Ie

AC-3

AUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)D13 (110 V) D24 (230 V) D34 (400 V)

CWCH07-10-30 5.6

1NO Upon request 1) 12680905 Upon request 1) 502,00

CWCH07-01-30 1NC Upon request 1) 12680906 Upon request 1) 502,00

CWCH09-10-30 7.2

1NO Upon request 1) 12680907 Upon request 1) 536,00

CWCH09-01-30 1NC Upon request 1) 12680908 Upon request 1) 536,00

CWCH012-10-30 9.6

1NO Upon request 1) 12680909 Upon request 1) 550,00

CWCH012-01-30 1NC Upon request 1) 12680910 Upon request 1) 550,00

CWCH016-10-30 12.8

1NO Upon request 1) 12680911 Upon request 1) 568,00

CWCH016-01-30 1NC Upon request 1) 12680912 Upon request 1) 568,00

TYPE

RATED CURRENT

Ie

AC-3

AUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)C03 (24 VDC) C12 (110 VDC) C15 (220 VDC)

CWCH07-10-30 5.6

1NO / 1NA 12680931 Upon request 1) Upon request 1) 609,00

CWCH07-01-30 1NC 12680932 Upon request 1) Upon request 1) 609,00

CWCH09-10-30 7.2

1NO / 1NA 12680933 Upon request 1) Upon request 1) 665,00

CWCH09-01-30 1NC 12680934 Upon request 1) Upon request 1) 665,00

CWCH012-10-30 9.6

1NO / 1NA 12680935 Upon request 1) Upon request 1) 668,00

CWCH012-01-30 1NC 12680936 Upon request 1) Upon request 1) 668,00

CWCH016-10-30 12.8

1NO / 1NA 12680937 Upon request 1) Upon request 1) 706,00

CWCH016-01-30 1NC 12680948 Upon request 1) Upon request 1) 706,00

wwwww..zestt.coo.zzaa

cccttttttooorrrsss

The New Generation of WEG Components for Motor Starting and Protection

Page 32: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

60 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 61

3-Pole Compact Contactors

COMPACT CONTACTORS CWC0_I - SCREW TYPE

TYPERATED POWER

AC-3 / 400 V (kW)

RATED CURRENT

AUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC-1D13 (110 V) D24 (230 V) D34 (400 V)

CWC07-10-30 I3 7 18

1NO Upon request 1) 12681721 Upon request 1) 373,00

CWC07-01-30 I 1NC Upon request 1) 12681722 Upon request 1) 394,00

CWC09-10-30 I4 9 20

1NO Upon request 1) 12681723 Upon request 1) 394,00

CWC09-01-30 I 1NC Upon request 1) 12681725 Upon request 1) 403,00

CWC012-10-30 I6 12 22

1NO Upon request 1) 12681726 Upon request 1) 403,00

CWC012-01-30 I 1NC Upon request 1) 12681727 Upon request 1) 414,00

CWC016-10-30 I7.5 16 22

1NO Upon request 1) 12681728 Upon request 1) 414,00

CWC016-01-30 I 1NC Upon request 1) 12681729 Upon request 1) 414,00

COMPACT CONTACTORS FOR PRINTED CIRCUIT BOARD - 7 TO 16 A - AC COIL

TYPERATED POWER

AC-3 / 400 V (kW)

RATED CURRENT

AUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC-1C03 (24 VDC) C12 (110 VDC) C15 (220 VDC)

CWC07-10-30 I3 7 18

1NO 12681759 Upon request 1) Upon request 1) 438,00

CWC07-01-30 I 1NC 12681760 Upon request 1) Upon request 1) 438,00

CWC09-10-30 I4 9 20

1NO 12681761 Upon request 1) Upon request 1) 473,00

CWC09-01-30 I 1NC 12681762 Upon request 1) Upon request 1) 473,00

CWC012-10-30 I6 12 22

1NO 12681763 Upon request 1) Upon request 1) 475,00

CWC012-01-30 I 1NC 12681764 Upon request 1) Upon request 1) 475,00

CWC016-10-30 I7.5 16 22

1NO 12681765 Upon request 1) Upon request 1) 499,00

CWC016-01-30 I 1NC 12681766 Upon request 1) Upon request 1) 499,00

COMPACT CONTACTORS FOR PRINTED CIRCUIT BOARD - 7 TO 16 A - DC COIL - STANDARD CONSUMPTION

Note : 1) Upon Request.

2) Auxiliary block front mounting available at a maximum of 2 contacts.

Article numbers for other rated voltages and frequencies upon request.

- Smart code of the rated voltage.

TYPERATED POWER

AC-3 / 400 V (kW)

RATED CURRENT

AUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC-1L03 (24 VDC) L12 (110 VDC) L15 (220 VDC)

CWC07-10-30 I3 7 18

1NO 12486765 Upon request 1) Upon request 1) 446,00

CWC07-01-30 I 1NC 12486767 Upon request 1) Upon request 1) 446,00

CWC09-10-30 I4 9 20

1NO 12486778 Upon request 1) Upon request 1) 483,00

CWC09-01-30 I 1NC 12486780 Upon request 1) Upon request 1) 483,00

CWC012-10-30 I6 12 22

1NO 12486781 Upon request 1) Upon request 1) 484,00

CWC012-01-30 I 1NC 12486782 Upon request 1) Upon request 1) 484,00

CWC016-10-30 I7.5 16 22

1NO 12486783 Upon request 1) Upon request 1) 509,00

CWC016-01-30 I 1NC 12486784 Upon request 1) Upon request 1) 509,00

COMPACT CONTACTORS FOR PRINTED CIRCUIT BOARD - 7 TO 16 A - DC COIL - LOW CONSUMPTION 2)

The New Generation of WEG Components for Motor Starting and Protection

3-Pole Compact Contactors

COMPACT CONTACTORS CWC0 - SPRING TYPE

TYPERATED POWER

AC-3 / 400 V (kW)

RATED CURRENT

AUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC-1D13 (110 V) D24 (230 V) D34 (400 V)

CWC07-10-30 S3 7 18

1NO Upon request 1) 12681924 Upon request 1) 293,00

CWC07-01-30 S 1NC Upon request 1) 12681925 Upon request 1) 293,00

CWC09-10-30 S4 9 20

1NO Upon request 1) 12681927 Upon request 1) 316,00

CWC09-01-30 S 1NC Upon request 1) 12681938 Upon request 1) 316,00

CWC012-10-30 S6 12 22

1NO Upon request 1) 12681939 Upon request 1) 325,00

CWC012-01-30 S 1NC Upon request 1) 12681940 Upon request 1) 325,00

TYPERATED POWER

AC-3 / 400 V (kW)

RATED CURRENT

AUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC-1C03 (24 VDC) C12 (110 VDC) C15 (220 VDC)

CWC07-10-30 S3 7 18

1NO 12681949 Upon request 1) Upon request 1) 366,00

CWC07-01-30 S 1NC 12681951 Upon request 1) Upon request 1) 405,00

CWC09-10-30 S4 9 20

1NO 12681952 Upon request 1) Upon request 1) 405,00

CWC09-01-30 S 1NC 12681953 Upon request 1) Upon request 1) 407,00

CWC012-10-30 S6 12 22

1NO 12681954 Upon request 1) Upon request 1) 407,00

CWC012-01-30 S 1NC 12681955 Upon request 1) Upon request 1) 407,00

TYPE RATED POWER

AC-3 / 400 V (kW)

RATED CURRENT

AUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC-1L03 (24 VDC) L12 (110 VDC) L15 (220 VDC)

CWC07-10-30 S3 7 18

1NO 12681968 Upon request 1) Upon request 1) 373,00

CWC07-01-30 S 1NC 12681969 Upon request 1) Upon request 1) 413,00

CWC09-10-30 S4 9 20

1NO 12681970 Upon request 1) Upon request 1) 413,00

CWC09-01-30 S 1NC 12681971 Upon request 1) Upon request 1) 415,00

CWC012-10-30 S6 12 22

1NO 12681972 Upon request 1) Upon request 1) 415,00

CWC012-01-30 S 1NC 12681973 Upon request 1) Upon request 1) 415,00

TYPERATED POWER

AC-3 / 400 V (kW)

RATED CURRENT

AUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC-1R03 (24 VDC) R12 (110 VDC) R15 (220 VDC)

CWC07-10-30 S3 7 18

1NO Upon request 1) Upon request 1) Upon request 1) Upon Request

CWC07-01-30 S 1NC Upon request 1) Upon request 1) Upon request 1) Upon Request

CWC09-10-30 S4 9 20

1NO Upon request 1) Upon request 1) Upon request 1) Upon Request

CWC09-01-30 S 1NC Upon request 1) Upon request 1) Upon request 1) Upon Request

CWC012-10-30 S6 12 22

1NO Upon request 1) Upon request 1) Upon request 1) Upon Request

CWC012-01-30 S 1NC Upon request 1) Upon request 1) Upon request 1) Upon Request

COMPACT CONTACTORS CWC0_S - 7 TO 12 A - AC COIL

COMPACT CONTACTORS CWC0_S - 7 TO 12 A - DC COIL - STANDARD CONSUMPTION

COMPACT CONTACTORS CWC0_S - 7 TO 12 A - DC COIL - LOW CONSUMPTION

COMPACT CONTACTORS CWC0_S - 7 TO 12 A - 0.75 X UC DC COIL - STANDARD CONSUMPTION

Note : 1) Upon Request.

- Smart code of the rated voltage.

wwwww..zestt.coo.zzaa

ttttttooorrrsss

The New Generation of WEG Components for Motor Starting and Protection

Page 33: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

62 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 63

COMPACT CONTACTORS CWCI0 - SPRING TYPE

TYPE

RATED CURRENT

Ie

AC-3

AUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)D13 (24 V) D24 (230 V) D34 (400 V)

CWCI07-10-30 S 7 1NO Upon request 1) 12681994 Upon request 1) 658,00

CWCI07-01-30 S 7 1NC Upon request 1) 12681995 Upon request 1) 658,00

CWCI09-10-30 S 9 1NO Upon request 1) 12681996 Upon request 1) 705,00

CWCI09-01-30 S 9 1NC Upon request 1) 12681997 Upon request 1) 705,00

CWCI012-10-30 S 12 1NO Upon request 1) 12681999 Upon request 1) 724,00

CWCI012-01-30 S 12 1NC Upon request 1) 12682000 Upon request 1) 724,00

TYPE

RATED CURRENT

Ie

AC-3

AUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)C03 (24 V DC/CC) C12 (110 V DC/CC) C15 (220 V DC/CC)

CWCI07-10-30 S 7 1NO 12682007 Upon request 1) Upon request 1) 820,00

CWCI07-01-30 S 7 1NC 12682090 Upon request 1) Upon request 1) 820,00

CWCI09-10-30 S 9 1NO 12682091 Upon request 1) Upon request 1) 899,00

CWCI09-01-30 S 9 1NC 12682092 Upon request 1) Upon request 1) 899,00

CWCI012-10-30 S 12 1NO 12682094 Upon request 1) Upon request 1) 903,00

CWCI012-01-30 S 12 1NC 12682095 Upon request 1) Upon request 1) 903,00

COMPACT CONTACTORS CWCI0_S WITH MECHANICAL INTERLOCK - 7 TO 12 A - AC COIL

COMPACT CONTACTORS CWCI0_S WITH MECHANICAL INTERLOCK - 7 TO 12 A - DC COIL

Note : 1) Upon Request..

- Smart code of the rated voltage.

3-Pole Compact Contactors

The New Generation of WEG Components for Motor Starting and Protection

COMPACT CONTACTORS CWCH0 - SPRING TYPE

COMPACT CONTACTORS WITH LATCH BLOCK CWCH0_S - 7 TO 12 A - AC COIL

TYPE

RATED CURRENT

Ie

AC-3

AUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)D13 (110 V) D24 (230 V) D34 (400 V)

CWCH07-01-30 S 7 1NO Upon request 1) 12682360 Upon request 1) 552,00

CWCH07-10-30 S 7 1NC Upon request 1) 12682361 Upon request 1) 552,00

CWCH09-01-30 S 9 1NO Upon request 1) 12682362 Upon request 1) 589,00

CWCH09-10-30 S 9 1NC Upon request 1) 12682363 Upon request 1) 589,00

CWCH012-01-30 S 12 1NO Upon request 1) 12682364 Upon request 1) 605,00

CWCH012-10-30 S 12 1NC Upon request 1) 12682365 Upon request 1) 605,00

COMPACT CONTACTORS WITH LATCH BLOCK CWCH0_S - 7 TO 12 A - DC COIL

TYPE

RATED CURRENT

Ie

AC-3

AUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)C03 (24 VDC) C12 (110 VDC) C15 (220 VDC)

CWCH07-10-30 S 7 1NO 12682372 Upon request 1) Upon request 1) 670,00

CWCH07-01-30 S 7 1NC 12682373 Upon request 1) Upon request 1) 670,00

CWCH09-10-30 S 9 1NO 12682374 Upon request 1) Upon request 1) 732,00

CWCH09-01-30 S 9 1NC 12682375 Upon request 1) Upon request 1) 732,00

CWCH012-10-30 S 12 1NO 12682376 Upon request 1) Upon request 1) 735,00

CWCH012-01-30 S 12 1NC 12682398 Upon request 1) Upon request 1) 735,00

Note : 1) Upon Request..

Auxiliary block front mounting available at a maximum of 2 contacts.

- Smart code of the rated voltage.

3-Pole Compact Contactors

wwwww..zestt.coo.zzaa

ttttttooorrrsss

The New Generation of WEG Components for Motor Starting and Protection

Page 34: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

64 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 65

POWER CIRCUIT

Reference code CWC07 CWC09 CWC012 CWC016 CWC025

Rated operational current Ie

AC-3 (Ue ≤ 440 V) (A) 7 9 12 16 22

AC-4 (Ue ≤ 440 V) (A) 2.8 3.5 4.5 5 9

AC-1 ( ≤ 55 °C, Ue ≤ 690 V) (A) 18 20 22 22 32

Rated operational voltage Ue

IEC/EN 60947-4-1, VDE 0660 (V) 690

UL, CSA 1) (V) 600

Rated thermal current Ith ( ≤ 55 °C) (A) 18 20 22 22 32

Making capacity - IEC/EN 60947 (A) 70 90 120 160 250

Breaking capacity

IEC/EN 60947

(Ue≤400 V) (A) 50 72 96 128 200

(Ue=500 V) (A) 50 72 96 128 200

(Ue=690 V) (A) 35 54 72 96 150

Short-time current (no current

flowing during recovery time of 10

min and ≤ 40 °C)

1 seg (A) 250 250 250 250 -

5 seg (A) 125 125 125 125 -

10 seg (A) 95 95 95 95 -

30 seg (A) 70 70 70 70 -

1 min (A) 50 50 50 50 -

3 min (A) 40 40 40 40 -

Protection against

short-circuits with

fuses (gL/gG)

@600 V - UL/CSA 1) (kA) 5

Coordination type 1 (A) 35 35 35 35 50

Coordination type 2 (A) 20 20 25 25 35

Average impedance per pole (mΩ) 6 6 5 5 6

Average power dissipation per poleAC-1 (W) 1.9 2.4 2.4 2.4 6.1

AC-3 (W) 0.3 0.5 0.7 1.3 3.8

Utilization category

Rated operational current Ie

( ≤ 55 °C)

Ue ≤ 440 V (A) 7 9 12 16 22

Ue ≤ 500 V (A) 6.2 7.5 8.8 13 16

Ue ≤ 690 V (A) 4.5 5.5 6.6 10 13

Ue ≤ 1000 V (A) Not available

Rated operational power 1)

220 / 230 V (kW) 1.5 2.2 3 3.7 5.5

(cv) 2 3 4 5 7.5

380 / V (kW) 3 3.7 5.5 7.5 11

(cv) 4 5 7.5 10 15

400 / 415 V (kW) 3 3.7 5.5 7.5 11

(cv) 4 5 7.5 10 15

440 V (kW) 3.7 4.5 5.5 7.5 11

(cv) 5 6 7.5 10 15

500 V (kW) 3.7 4.5 5.5 7.5 11

(cv) 5 6 7.5 10 15

660 / 690 V (kW) 3 3.7 5.5 7.5 11

(cv) 4 5 7.5 10 15

Max. electrical

operational per hour

600 ops./h (%) 100 100 100 100 100

1200 ops./h (%) 75 75 75 75 75

3000 ops./h (%) 50 50 50 50 50

Utilization category AC-4

Rated operational current Ie AC-4 (U

e ≤ 440 V) (A) 2.8 3.5 4.5 5 9

Rated operational power 1)

(200,000 operations)

220 / 230 V (kW) 0.55 0.75 0.75 1.1 2.2

(cv) 0.7 1 1 1.5 2.9

380 / 400 V (kW) 1.1 1.1 1.8 2.2 4

(cv) 1.5 1.5 2.4 2.9 5.4

415 V (kW) 1.1 1.5 2.2 2.2 4.5

(cv) 1.5 2 2.9 2.9 6

440 V (kW) 1.1 1.5 2.2 2.2 4.5

(cv) 1.5 2 2.9 2.9 6

500 V (kW) 1.1 1.5 2.2 2.2 4.5

(cv) 1.5 2 2.9 2.9 6

660 / 690 V (kW) 1.1 1.5 2.2 2.2 4.5

(cv) 1.5 2 2.9 2.9 6

Note: 1) For 50/60 Hz three-phase, 4 poles WEG standard motors. These values are only for reference and may change on the number of poles and motor design.

Compact Contactors CWC0 - Technical Data

za

WWWWWWWWCCCCCCCCC00000000 - TTTTTTTTeeeccchhhhhhhnnniiiiiiicccaaalllllll DDDDDDDaaatttttaaa

The New Generation of WEG Components for Motor Starting and Protection

POWER CIRCUIT

Reference code

CWC07 CWC09 CWC012 CWC016 CWC025

Utilization category AC-1

3P (NO) or 4P (4NO) 3P (NO)

Rated thermal current Ith ( ≤ 55 °C) (A) 18 20 22 22 32

Maximum operational current

(up to 690 V)

≤ 40 °C (A) 18 20 22 22 32

≤ 55 °C (A) 18 20 22 22 32

≤ 70 °C (A) 14.4 16 17.6 17.6 25.6

Maximum operational power

≤ 55 °C

3-phase resistors

220 / 230 V (kW) 6.8 7.5 8.3 8.3 12

380 / 400 V (kW) 11.5 13 14.5 14.5 21

415 / 440 V (kW) 13 14.5 16 16 23

500 V (kW) 14.8 16.5 18 18 26

660 / 690 V (kW) 20 22 25 25 36

Current values for connection of

2 poles in parallel Ie x 1.7

3 poles in parallel Ie x 2.4

4 poles in parallel Ie x 3.2

Percentage of the max.

operational current at

600 ops./h (%)

1001200 ops./h (%)

3000 ops./h (%)

2P (NO/NC) or 4P (2NO + 2NC) 2P (NO/NC)

Maximum operational power

≤ 55 °C

(resistive load)

220 / 230 V (kW) 3.9 4.4 4.8 4.8 6.6

380 / 400 V (kW) 6.8 7.6 8.4 8.4 11.4

415 / 440 V (kW) 7.5 8.4 9.2 9.2 12.5

500 V (kW) 8.6 9.5 10.5 10.5 14.5

660 / 690 V (kW) 11.8 13.1 14.4 14.4 19.5

BUILT-IN AUXILIARY CONTACTS

UL POWER RATINGS

Reference code CWC07...16 CWCA0

Standards IEC 60947-5-1, IEC 60947-4-1

Rated insulation voltage Ui

(pollution degree 3)

IEC, VDE 0660 (V) 690

UL, CSA (V) 600

Rated operational voltage Ue

IEC, VDE 0660 (V) 690

UL, CSA (V) 600

Rated thermal current Ith ( ≤ 55 °C) (A) 10

Rated operational current Ie

AC-15 (IEC 60947-5-1)

Ue ≤ 240 V (A) 10

380-400 V (A) 6

415-440 V (A) 5

500 V (A) 4

660-690 V (A) 2

UL, CSA A600

DC-13 (IEC 60947-5-1)

24 V (A) 6

48 V (A) 4

110 V (A) 2

220 V (A) 0.7

UL, CSA Q600

Making capacity (rms) Ue ≤ 400 V 50/60 Hz - AC-15 (A) 10 x I

e (AC-15)

Breaking capacity (rms) Ue ≤ 400 V 50/60 Hz - AC-15 (A) 10 x I

e (AC-15)

Max.fuse class gL-gG without welding

(short-circuit protection) gL/gG (A) 10

Control circuit reliability (V / mA) 17 / 5

Electrical endurance (millions operations) 1

Mechanical endurance (millions operations) 10

Compact Contactors CWC0 - Technical Data

Reference code CWC07 CWC09 CWC012 CWC016 CWC025

General purpose current (600 V) (A) 18 20 22 22 30

1-phase

110 / 120 V (hp) 1/3 1/3 1/2 1 1 1/2

208 V (hp) 3/4 1/2 1/2 2 3

220 / 240 V (hp) 3/4 1/2 2 2 3

3-phase

110 / 120 V (hp) 3/4 1 1 1/2 2 3

200 V (hp) 1 1/2 2 3 3 5

220 / 240 V (hp) 1 1/2 3 3 5 7 1/2

440 / 480 V (hp) 5 5 7 1/2 10 15

550 / 600 V (hp) 5 7 1/2 7 1/2 10 15

wwww.zeest.co.zzaa

- TTTTTTTTeeeccchhhhhhhhnnniiiiiiiicccaaalllllll DDDDDDDDaaattttttaaa

CWC016

eest.cThe New Generation of WEG Components

for Motor Starting and Protection

Page 35: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

66 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 67

Accessories for Compact Contactors “CWC0”

ACCESSORIES FOR COMPACT CONTACTORS CWC0

ON-DELAY ELECTRONIC TIMER BLOCK

TYPE SUPPLY VOLTAGE TIMING STOCK CODE PRICE EACH (ZAR)

TEC0-U003S-E05

E05

24-240 VAC / VDC

0.3s...3s 12499386 871,00

TEC0-U010S-E05 1s...10s 12499398 871,00

TEC0-U030S-E05 3s...30s 12499445 871,00

TEC0-U060S-E05 6s...60s 12499447 871,00

TEC0-U100S-E05 10s...100s 12499399 871,00

TEC0-U300S-E05 30s...300s 12499400 871,00

TEC0-U030M-E05 3min...30min 12499461 871,00

OFF-DELAY ELECTRONIC TIMER BLOCK

TYPE SUPPLY VOLTAGE TIMING STOCK CODE PRICE EACH (ZAR)

TDC0-U003S-E09

E09

100-240 VAC / VDC

0.3s...3s 12499462 1127,00

TDC0-U010S-E09 1s...10s 12499439 1127,00

TDC0-U030S-E09 3s...30s 12499463 1127,00

TDC0-U060S-E09 6s...60s 12499440 1127,00

TDC0-U100S-E09 10s...100s 12499441 1127,00

TDC0-U300S-E09 30s...300s 12499442 1127,00

TDC0-U030M-E09 3min...30min 12499464 1127,00

STAR-DELTA ELECTRONIC TIMER BLOCK

TYPE SUPPLY VOLTAGE TIMING STOCK CODE PRICE EACH (ZAR)

TETC0-U030S-D52 24-28 VAC 3s...30s 12499443 902,00

TETC0-U030S-D61 110-130 VAC 3s...30s 12499459 902,00

TETC0-U030S-D66 220-240 VAC 3s...30s 12499387 902,00

OFF-DELAY ELECTRONIC TIMER BLOCK

TYPE SUPPLY VOLTAGE TIMING STOCK CODE PRICE EACH (ZAR)

TDC0-U003S-E04

E04

24-60 VAC / VDC

0.3s...3s 12499401 1127,00

TDC0-U010S-E04 1s...10s 12499402 1127,00

TDC0-U030S-E04 3s...30s 12499403 1127,00

TDC0-U060S-E04 6s...60s 12499407 1127,00

TDC0-U100S-E04 10s...100s 12499404 1127,00

TDC0-U300S-E04 30s...300s 12499405 1127,00

TDC0-U030M-E04 3min...30min 12499438 1127,00

ooonnnttttttaaacccttttttooorrrsss “““““CCCCCCCCWWWWWWWCCCCCCCC0000000”””””

The New Generation of WEG Components for Motor Starting and Protection

Accessories for Compact Contactors

ACCESSORIES FOR COMPACT CONTACTORS CWC0

AUXILIARY CONTACT BLOCK - SCREW TYPE

TYPE MOUNTING TO USE WITH AUX. CONTACTS STOCK CODEPRICE EACH

(ZAR)

BFC0-20

Frontal

CWC0

3-Pole

2-Pole

2NO 12499352 110,00

BFC0-11 1NO + 1NC 12499350 110,00

BFC0-02 2NC 12499348 110,00

BFC0-40 4NO 12499359 173,00

BFC0-22 2NO + 2NC 12499353 173,00

BFC0-04 1) 4NC 12499349 173,00

BFC0-31 3NO + 1NC 12499358 173,00

BFC0-13 1) 1NO + 3NC 12499351 173,00

BFC025-20

Frontal

CWC025

3-Pole

2-Pole

2NO 12499356 110,00

BFC025-11 1NO + 1NC 12499355 110,00

BFC025-02 2NC 12499354 110,00

BFC025-22Z 2NO + 2NC 12499357 173,00

BFC4-20

FrontalCWC0

4-Pole

2NO 12499364 110,00

BFC4-11 1NO + 1NC 12499362 110,00

BFC4-02 2NC 12499360 110,00

BFC4-40 4NO 12499367 173,00

BFC4-22 2NO + 2NC 12499365 173,00

BFC4-04 1) 4NC 12499361 173,00

BFC4-31 3NO + 1NC 12499366 173,00

BFC4-13 1) 1NO + 3NC 12499363 173,00

BFCA-20

FrontalCWCA0

Relay / Auxiliar

2NO 12499382 110,00

BFCA-11 1NO + 1NC 12499380 110,00

BFCA-02 2NC 12499378 110,00

BFCA-40 4NO 12499385 173,00

BFCA-22 2NO + 2NC 12499383 173,00

BFCA-04 1) 4NC 12499379 173,00

BFCA-31 3NO + 1NC 12499384 173,00

BFCA-13 1) 1NO + 3NC 12499381 173,00

Note : 1) The auxiliary contact blocks with configurations “-13” or “-04” only must be used in compact contactors with AC coil or 0.75xUc DC coil.

wwwww..zestt.coo.zzaa

ccctttttt CCCCCCCooonnnttttttaaacccttttttooorrrsss

The New Generation of WEG Components for Motor Starting and Protection

Page 36: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

68 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 69

Accessories for Compact Contactors

ACCESSORIES FOR COMPACT CONTACTORS CWC0

AUXILIARY CONTACT BLOCK - SPRING TYPE

TYPE MOUNTING TO USE WITH AUX. CONTACTS STOCK CODEPRICE EACH

(ZAR)

BFC0-20S

Front

CWC0

3-Pole

2-Pole

2NO 12499237 121,00

BFC0-11S 1NO + 1NC 12499235 121,00

BFC0-02S 2NC 12499107 121,00

BFC0-40S 4NO 12499310 191,00

BFC0-22S 2NO + 2NC 12499308 191,00

BFC0-04S 1) 4NC 12499228 191,00

BFC0-31S 3NO + 1NC 12499309 191,00

BFC0-13S 1) 1NO + 3NC 12499236 191,00

BFC4-20S

Front CWC0

4-Pole

2NO 12499315 121,00

BFC4-11S 1NO + 1NC 12499313 121,00

BFC4-02S 2NC 12499311 121,00

BFC4-40S 4NO 12499318 191,00

BFC4-22S 2NO + 2NC 12499316 191,00

BFC4-04S 1) 4NC 12499312 191,00

BFC4-31S 3NO + 1NC 12499317 191,00

BFC4-13S 1) 1NO + 3NC 12499314 191,00

BFCA-20S

FrontCWCA0

Relay

2NO 12499324 118,00

BFCA-11S 1NO + 1NC 12499321 118,00

BFCA-02S 2NC 12499319 118,00

BFCA-40S 4NO 12499327 191,00

BFCA-22S 2NO + 2NC 12499325 191,00

BFCA-04S 1) 4NC 12499320 191,00

BFCA-31S 3NO + 1NC 12499326 191,00

BFCA-13S 1) 1NO + 3NC 12499322 191,00

Note : 1) The auxiliary contact blocks with configurations “-13” or “-04” only must be used in compact contactors with AC coil or 0.75xUc DC coil.

ooonnnttttttaaacccttttttooorrrsss

The New Generation of WEG Components for Motor Starting and Protection

Accessories for Compact Contactors

ACCESSORIES FOR COMPACT CONTACTORS CWC0

SURGE SUPPRESSOR BLOCK

PRINTED CIRCUIT BOARD CONNECTOR

MECHANICAL INTERLOCK BLOCK

BUS BAR SYSTEM - EASY CONNECTION KIT

LATCH BLOCK

TYPE MOUNTING RATED VOLTAGE STOCK CODEPRICE EACH

(ZAR)

RCC0-1 D49

Frontal

12-24 V 50/60 Hz 12500583 104,00

RCC0-2 D53 24-48 V 50/60 Hz 12500584 104,00

RCC0-3 D55 48-127 V 50/60 Hz 12500585 104,00

RCC0-4 D63 127-250 V 50/60 Hz 12500586 104,00

RCC0-5 D84 250-380 V 50/60 Hz 12500587 104,00

RCC0-6 D73 380-510 V 50/60 Hz 12500628 104,00

RCAC0 D87 180-230 V 50/60 Hz 12500629 104,00

VRC0-1 E49 12-48 V ac/ca / 12-60 V dc/cc 12500630 104,00

VRC0-2 E34 50-127 V ac/ca / 60-180 V dc/cc 12500632 104,00

VRC0-3 E50 130-275 V ac/ca / 180-300 V dc/cc 12500633 104,00

VRC0-4 E41 277-380 V ac/ca / 300-510 V dc/cc 12500634 104,00

VRC0-5 D73 400-510 V ac/ca 50/60 Hz 12500636 104,00

DIC0-1 C33 12-600 V dc/cc 12500637 104,00

DIZC0 C26 12-250 V dc/cc 12500649 104,00

TYPE STOCK CODEPRICE EACH

(ZAR)

CIC0 10075988 102,00

TYPE TO USE WITH MOUNTING STOCK CODEPRICE EACH

(ZAR)

BIC0 CWC07-016 Front al 12499466 64,00

TYPE TO USE WITH STOCK CODEPRICE EACH

(ZAR)

ECC0-R Reversing power and control circuits 10047150 276,00

ECC0-RNI Reversing - power circuit 11788681 297,00

ECC0-SD Star-delta power and control 10047151 309,00

TYPE STOCK CODEPRICE EACH

(ZAR)

RMC0 12499467 74,00

wwwww..zestt.coo.zzaa

ccctttt CCCCCCooonnnttttaaacccttttooorrrsss

The New Generation of WEG Components for Motor Starting and Protection

Page 37: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

70 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 71

Control Relays

CONTROL RELAYS CWCA0 - SCREW TYPE

TYPE Ith

Ie

AC-15 / 220 VAUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)D02 (24 V) D13 (110 V) D24 (230 V) D34 (400 V)

CWCA0-22-00

10 10

2NO + 2NC 12487308 12487317 12487358 12680436 266,00

CWCA0-31-00 3NO + 1NC 12487312 12487365 12680433 12680437 266,00

CWCA0-13-00 1NO + 3NC 12680317 12680430 12680434 12680438 266,00

CWCA0-40-00 4NO 12680428 12680431 12487236 12680439 266,00

CWCA0-04-00 4NC 12680429 12680432 12680435 12680440 266,00

CONTROL RELAYS “CWCA0” - AC COIL

TYPE Ith

Ie

AC-15 / 220 VAUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)C03 (24 V DC/CC) C12 (110 V DC/CC) C15 (220 V DC/CC)

CWCA0-22-00

10 10

2NO + 2NC 12486869 12486874 Upon request 2) 333,00

CWCA0-31-00 3NO + 1NC 12486870 12486875 Upon request 2) 333,00

CWCA0-13-00 1NO + 3NC 12486871 12486876 Upon request 2) 333,00

CWCA0-40-00 4NO 12486872 12486877 Upon request 2) 333,00

CWCA0-04-00 4NC 12486873 12486878 Upon request 2) 333,00

CONTROL RELAYS “CWCA0” - DC COIL - STANDARD CONSUMPTION

TYPE Ith

Ie

AC-15 / 220 VAUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)L03 (24 V DC/CC) L12 (110 V DC/CC) L15 (220 V DC/CC)

CWCA0-22-00

10 10

2NO + 2NC 12486879 Upon request 2) Upon request 2) 339,00

CWCA0-31-00 3NO + 1NC 12486880 Upon request 2) Upon request 2) 339,00

CWCA0-13-00 1NO + 3NC 12486881 Upon request 2) Upon request 2) 339,00

CWCA0-40-00 4NO 12486882 Upon request 2) Upon request 2) 339,00

CWCA0-04-00 4NC 12486883 Upon request 2) Upon request 2) 339,00

CONTROL RELAYS “CWCA0” - DC COIL - LOW CONSUMPTION

TYPE Ith

Ie

AC-15 / 220 VAUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)R03 (24 V DC/CC) R12 (110 V DC/CC) R15 (220 V DC/CC)

CWCA0-22-00

10 10

2NO + 2NC Upon request 2) Upon request 2) Upon request 2) Upon request

CWCA0-31-00 3NO + 1NC Upon request 2) Upon request 2) Upon request 2) Upon request

CWCA0-13-00 1NO + 3NC Upon request 2) Upon request 2) Upon request 2) Upon request

CWCA0-40-00 4NO Upon request 2) Upon request 2) Upon request 2) Upon request

CWCA0-04-00 4NC Upon request 2) Upon request 2) Upon request 2) Upon request

CONTROL RELAYS “CWCA0” - 0.75 X UC DC COIL - STANDARD CONSUMPTION

Note : 1) Upon Request.

2) Auxiliary block front mounting available at a maximum of 2 contacts.

Article numbers for other rated voltages and frequencies upon request.

- Smart code of the rated voltage.

The New Generation of WEG Components for Motor Starting and Protection

CONTROL RELAYS CWCHA0 - SCREW TYPE

TYPE Ith

Ie

AC-15 / 220 VAUX. CONTACT

STOCK CODEPRICE EACH

(ZAR)D13 (110 V) D24 (230 V) D34 (400 V)

CWCHA0-22-00

10 10

2NO + 2NC Upon request 1) 12682602 Upon request 1) 502,00

CWCHA0-31-00 3NO + 1NC Upon request 1) 12682603 Upon request 1) 502,00

CWCHA0-40-00 4NO Upon request 1) 12682604 Upon request 1) 502,00

CONTROL RELAYS WITH LATCH BLOCK “CWCHA0” - AC COIL

TYPE Ith

Ie

AC-15 / 220 VAUX. CONTACT

STOCK CODEPRICE EACH

(ZAR)C03 (24 V DC/CC) C12 (110 V DC/CC) C15 (220 V DC/CC)

CWCHA0-22-00

10 10

2NO + 2NC Upon request 1) Upon request 1) Upon request 1) Upon request

CWCHA0-31-00 3NO + 1NC Upon request 1) Upon request 1) Upon request 1) Upon request

CWCHA0-40-00 4NO Upon request 1) Upon request 1) Upon request 1) Upon request

CONTROL RELAYS WITH LATCH BLOCK “CWCHA0” - DC COIL

Control Relays

Note : 1) Upon Request.

2) Auxiliary block front mounting available at a maximum of 2 contacts.

- Smart code of the rated voltage.

wwwww..zestt.coo.zzaaThe New Generation of WEG Components

for Motor Starting and Protection

Page 38: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

72 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 73

Control Relays

CONTROL RELAYS CWCA0 - SPRING TYPE

CONTROL RELAYS “CWCA0_S” - AC COIL

TYPE Ith

Ie

AC-15 / 220 VAUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)D13 (110 V) D24 (230 V) D34 (400 V)

CWCA0-22-00 S

10 10

2NO + 2NC Upon request 1) 12683051 Upon request 1) 293,00

CWCA0-31-00 S 3NO + 1NC Upon request 1) 12683052 Upon request 1) 293,00

CWCA0-13-00 S 1NO + 3NC Upon request 1) 12683053 Upon request 1) 293,00

CWCA0-40-00 S 4NO Upon request 1) 12683054 Upon request 1) 293,00

CWCA0-04-00 S 4NC Upon request 1) 12683055 Upon request 1) 293,00

CONTROL RELAYS “CWCA0_S” - DC COIL - STANDARD CONSUMPTION

TYPE Ith

Ie

AC-15 / 220 VAUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)C03 (24 VDC) C12 (110 VDC) C15 (220 VDC)

CWCA0-22-00 S

10 10

2NO + 2NC Upon request 1) Upon request 1) Upon request 1) Upon request

CWCA0-31-00 S 3NO + 1NC Upon request 1) Upon request 1) Upon request 1) Upon request

CWCA0-13-00 S 1NO + 3NC Upon request 1) Upon request 1) Upon request 1) Upon request

CWCA0-40-00 S 4NO Upon request 1) Upon request 1) Upon request 1) Upon request

CWCA0-04-00 S 4NC Upon request 1) Upon request 1) Upon request 1) Upon request

Note : 1) Upon Request.

2) Auxiliary block front mounting available at a maximum of 2 contacts.

- Smart code of the rated voltage.

CONTROL RELAYS “CWCA0_S” - 0.75 X UC DC COIL - STANDARD CONSUMPTION

TYPE Ith

Ie

AC-15 / 220 VAUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)R03 (24 VDC) R12 (110 VDC) R15 (220 VDC)

CWCA0-22-00 S

10 10

2NO + 2NC Upon request 1) Upon request 1) Upon request 1) Upon request

CWCA0-31-00 S 3NO + 1NC Upon request 1) Upon request 1) Upon request 1) Upon request

CWCA0-13-00 S 1NO + 3NC Upon request 1) Upon request 1) Upon request 1) Upon request

CWCA0-40-00 S 4NO Upon request 1) Upon request 1) Upon request 1) Upon request

CWCA0-04-00 S 4NC Upon request 1) Upon request 1) Upon request 1) Upon request

CONTROL RELAYS “CWCA0_S” - DC COIL - LOW CONSUMPTION 2)

TYPE Ith

Ie

AC-15 / 220 VAUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)L03 (24 VDC) L12 (110 VDC) L15 (220 VDC)

CWCA0-22-00 S

10 10

2NO + 2NC Upon request 1) Upon request 1) Upon request 1) Upon request

CWCA0-31-00 S 3NO + 1NC Upon request 1) Upon request 1) Upon request 1) Upon request

CWCA0-13-00 S 1NO + 3NC Upon request 1) Upon request 1) Upon request 1) Upon request

CWCA0-40-00 S 4NO Upon request 1) Upon request 1) Upon request 1) Upon request

CWCA0-04-00 S 4NC Upon request 1) Upon request 1) Upon request 1) Upon request

The New Generation of WEG Components for Motor Starting and Protection

2-Pole Compact Contactors

2-POLE COMPACT CONTACTORS CWC0 - 7 TO 22A - AC COIL

TYPERATED POWER

AC-3 /400 V (kW)

RATED CURRENT

MAIN CONTACTS

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3 (A)

Ith

AC- 1D13 (110 V) D24 (230 V) D34 (400 V)

CWC07-00-20 3 7 18 2NO Upon request 1) 12683320 Upon request 1) 226,00

CWC07-00-02 3 7 18 2NC Upon request 1) 12683322 Upon request 1) 226,00

CWC09-00-20 4 9 20 2NO Upon request 1) 12683323 Upon request 1) 244,00

CWC09-00-02 4 9 20 2NC Upon request 1) 12683325 Upon request 1) 244,00

CWC012-00-20 5.5 12 22 2NO Upon request 1) 12683326 Upon request 1) 251,00

CWC012-00-02 5.5 12 22 2NC Upon request 1) 12683327 Upon request 1) 251,00

CWC016-00-20 7.5 16 22 2NO Upon request 1) 12683328 Upon request 1) 261,00

CWC016-00-02 7.5 16 22 2NC Upon request 1) 12683329 Upon request 1) 261,00

CWC025-00-20 11 22 32 2NO Upon request 1) 12683330 Upon request 1) 329,00

2-POLE COMPACT CONTACTORS “CWC0” - 7 TO 12A - AC COIL

TYPERATED POWER

AC-3 /400 V (kW)

RATED CURRENT

MAIN CONTACTS

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3 (A)

Ith

AC- 1D13 (110 V) D24 (230 V) D34 (400 V)

CWC07-00-20 S 3 7 18 2NO Upon request 1) 12683366 Upon request 1) 249,00

CWC07-00-02 S 3 7 18 2NC Upon request 1) 12683367 Upon request 1) 249,00

CWC09-00-20 S 4 9 20 2NO Upon request 1) 12683388 Upon request 1) 268,00

CWC09-00-02 S 4 9 20 2NC Upon request 1) 12683389 Upon request 1) 268,00

CWC012-00-20 S 5.5 12 22 2NO Upon request 1) 12683390 Upon request 1) 276,00

CWC012-00-02 S 5.5 12 22 2NC Upon request 1) 12683391 Upon request 1) 276,00

Note : 1) Upon Request.

- Smart code of the rated voltage.

wwwww..zestt.coo.zzaa

ttttttooorrrsss

The New Generation of WEG Components for Motor Starting and Protection

Page 39: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

74 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 75

wwwww..zestt.coo.zzaa

4-Pole Compact Contactors

4-POLE COMPACT CONTACTORS CWC0 - SCREW TYPE

4-POLE COMPACT CONTACTORS “CWC0” 7 TO 16A - AC COIL

TYPERATED POWER

AC-3 /400 V (kW)

RATED CURRENTMAIN

CONTACTS

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC- 1D02 (24 V) D13 (110 V) D24 (230 V) D34 (400 V)

CWC07-00-40 3 7 18

4NO

Upon request 1) Upon request 1) 12683627 Upon request 1) 300,00

CWC09-00-40 4 9 20 Upon request 1) Upon request 1) 12683688 Upon request 1) 261,00

CWC012-00-40 5,5 1222

Upon request 1) Upon request 1) 12683690 Upon request 1) 327,00

CWC016-00-40 7,5 16 Upon request 1) Upon request 1) 12683691 Upon request 1) 277,00

CWC07-00-22 3 7 18

2NO + 2NC

Upon request 1) Upon request 1) 12683692 Upon request 1) 300,00

CWC09-00-22 4 9 20 Upon request 1) Upon request 1) 12683693 Upon request 1) 314,00

CWC012-00-22 5,5 1222

Upon request 1) Upon request 1) 12683694 Upon request 1) 327,00

CWC016-00-22 7,5 16 Upon request 1) Upon request 1) 12683695 Upon request 1) 327,00

4-POLE COMPACT CONTACTORS “CWC0” 7 TO 16A - DC COIL - STANDARD CONSUMPTION

TYPERATED POWER

AC-3 /400 V (kW)

RATED CURRENTMAIN

CONTACTS

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC- 1C03 (24 VDC ) C12 (110 VDC) C15 (220 VDC)

CWC07-00-40 3 7 18

4NO

Upon request 1) Upon request 1) Upon request 1) Upon request

CWC09-00-40 4 9 20 Upon request 1) Upon request 1) Upon request 1) Upon request

CWC012-00-40 5.5 12 22 Upon request 1) Upon request 1) Upon request 1) Upon request

CWC016-00-40 7.5 16 22 Upon request 1) Upon request 1) Upon request 1) Upon request

Note : 1) Upon Request.

2) Auxiliary block front mounting available at a maximum of 2 contacts.

- Smart code of the rated voltage.

4-POLE COMPACT CONTACTORS “CWC0” 7 TO 16A - DC COIL - LOW CONSUMPTION

TYPERATED POWER

AC-3 /400 V (kW)

RATED CURRENTMAIN

CONTACTS

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC- 1L03 (24 VDC) L12 (110 VDC) L15 (220 VDC)

CWC07-00-40 3 7 18

4NO

Upon request 1) Upon request 1) Upon request 1) Upon request

CWC09-00-40 4 9 20 Upon request 1) Upon request 1) Upon request 1) Upon request

CWC012-00-40 5.5 12 22 Upon request 1) Upon request 1) Upon request 1) Upon request

CWC016-00-40 7.5 16 22 Upon request 1) Upon request 1) Upon request 1) Upon request

4-POLE COMPACT CONTACTORS “CWC0” 7 TO 16A - 75% DC COIL - STANDARD CONSUMPTION

TYPERATED POWER

AC-3 /400 V (kW)

RATED CURRENTMAIN

CONTACTS

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC- 1R03 (24 VDC) R12 (110 VDC) R15 (220 VDC)

CWC07-00-22 3 7 18

2NO + 2NC

Upon request 1) Upon request 1) Upon request 1) Upon request

CWC09-00-22 4 9 20 Upon request 1) Upon request 1) Upon request 1) Upon request

CWC012-00-22 5.5 12 22 Upon request 1) Upon request 1) Upon request 1) Upon request

CWC016-00-22 7.5 16 22 Upon request 1) Upon request 1) Upon request 1) Upon request

Note: For applications where there is a significant reduction on the rated voltage, sometimes due to long distances or network problems.

The New Generation of WEG Components for Motor Starting and Protection

4-Pole Compact Contactors

4-POLE COMPACT CONTACTORS CWC0 - SPRING TYPE

4-POLE COMPACT CONTACTORS - “CWCO” 7 TO 12A - AC COIL

4-POLE COMPACT CONTACTORS - “CWC0” 7 TO 12A - DC COIL - LOW CONSUMPTION 2)

TYPERATED POWER

AC-3 /400 V (kW)

RATED CURRENTMAIN

CONTACTS

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC- 1D13 (110 V) D24 (230 V) D34 (400 V)

CWC07-00-40 S 3 7 18

4NO

Upon request 1) 12683721 Upon request 1) 304,00

CWC09-00-40 S 4 9 20 Upon request 1) 12683722 Upon request 1) 330,00

CWC012-00-40 S 5,5 12 22 Upon request 1) 12683723 Upon request 1) 345,00

CWC07-00-22 S 3 7 18

2NO + 2NC

Upon request 1) 12683724 Upon request 1) 304,00

CWC09-00-22 S 4 9 20 Upon request 1) 12683725 Upon request 1) 330,00

CWC012-00-22 S 5,5 12 22 Upon request 1) 12683726 Upon request 1) 345,00

4-POLE COMPACT CONTACTORS - “CWC0” 7 TO 12A - DC COIL - STANDARD CONSUMPTION

TYPERATED POWER

AC-3 /400 V (kW)

RATED CURRENTMAIN

CONTACTS

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC- 1C03 (24 VDC) C12 (110 VDC) C15 (220 VDC)

CWC07-00-40 S 3 7 18

4NO

Upon request 1) Upon request 1) Upon request 1) Upon request

CWC09-00-40 S 4 9 20 Upon request 1) Upon request 1) Upon request 1) Upon request

CWC012-00-40 S 5,5 12 22 Upon request 1) Upon request 1) Upon request 1) Upon request

TYPERATED POWER

AC-3 /400 V (kW)

RATED CURRENTMAIN

CONTACTS

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC- 1L03 (24 VDC) L12 (110 VDC) L15 (220 VDC)

CWC07-00-40 S 3 7 18

4NO

Upon request 1) Upon request 1) Upon request 1) Upon request

CWC09-00-40 S 4 9 20 Upon request 1) Upon request 1) Upon request 1) Upon request

CWC012-00-40 S 5,5 12 22 Upon request 1) Upon request 1) Upon request 1) Upon request

Note : 1) Upon Request.

2) Auxiliary block front mounting available at a maximum of 2 contacts.

- Smart code of the rated voltage.

4-POLE COMPACT CONTACTORS - “CWC0” 7 TO 12A - 75% DC COIL - STANDARD CONSUMPTION

TYPERATED POWER

AC-3 /400 V (kW)

RATED CURRENTMAIN

CONTACTS

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC- 1R03 (24 VDC) R12 (110 VDC) R15 (220 VDC)

CWC07-00-22 S 3 7 18

2NO + 2NC

Upon request 1) Upon request 1) Upon request 1) Upon request

CWC09-00-22 S 4 9 20 Upon request 1) Upon request 1) Upon request 1) Upon request

CWC012-00-22 S 5,5 12 22 Upon request 1) Upon request 1) Upon request 1) Upon request

Note : For applications where there is a significant reduction on the rated voltage, sometimes due to long distances or network problems.

The New Generation of WEG Components for Motor Starting and Protection

Page 40: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

76 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 77

Accessories for CWM 4-Pole Contactors

ACCESSORIES FOR 4-POLE COMPACT CONTACTORS CWC0

SPARE CONTACT SET

TYPE CONTACTORS STOCK CODEPRICE EACH

(ZAR)

JCC07-4P CWC07-00-40 10650966 146,00

JCC07-2P/2R CWC07-00-22 10662929 146,00

JCC09-4P CWC09-00-40 10212411 162,00

JCC09-2P/2R CWC09-00-22 10212412 162,00

JCC012-4P CWC012-00-40 10212413 165,00

JCC012-2P/2R CWC012-00-22 10212414 165,00

JCC016-4P CWC016-00-40 10212415 176,00

JCC016-2P/2R CWC016-00-22 10212416 176,00

TYPE CONTACTORS STOCK CODEPRICE EACH

(ZAR)

JCCB07-4P CWC07-00-40 10212403 146,00

JCCB07-2P/2R CWC07-00-22 10212404 146,00

JCCB09-4P CWC09-00-40 10212405 162,00

JCCB09-2P/2R CWC09-00-22 10212406 162,00

JCCB012-4P CWC012-00-40 10212407 165,00

JCCB012-2P/2R CWC012-00-22 10212408 165,00

JCCB016-4P CWC016-00-40 10212409 176,00

JCCB016-2P/2R CWC016-00-22 10212410 176,00

Note : Other accessories for 4-Pole contactors, see 3-Pole contactor’s accessories.

CONTACTORS - DC COIL

CONTACTORS - AC COIL

eeee CCCCCCCCCoooonnnntttttttaaaacccctttttttoooorrrssss

The New Generation of WEG Components for Motor Starting and Protection

3-Pole Compact Contactors

COMPACT CONTACTORS CWC0 - SCREW TYPE

TYPERATED POWER

AC-3 / 400 V (kW)

RATED CURRENT

AUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC-1D02 (24 V) D13 (110 V) D24 (230 V) D34 (400 V)

CWC07-10-30 3 7 18

1NO 10047356 10047489 10047165 10645766 266,00

CWC07-01-30 1NC 10047355 10047490 10648757 10075389 287,00

CWC09-10-30 4 9 20

1NO 10047358 10047491 10410431 10648377 287,00

CWC09-01-30 1NC 10047357 10047492 10186761 10647703 296,00

CWC012-10-30 5.5 12 22

1NO 10047352 10047493 10047166 10648332 296,00

CWC012-01-30 1NC 10047351 10047494 10047167 10648119 307,00

CWC016-10-30 7.5 16 22

1NO 10047354 10047495 10186762 10212631 307,00

CWC016-01-30 1NC 10047353 10047496 10186763 10075390 388,00

CWC025-00-30 11 22 32 - 11079118 10858105 10866996 10866997 388,00

COMPACT CONTACTORS CWC0 - 7 TO 22 A - AC COIL

TYPERATED POWER

AC-3 / 400 V (kW)

RATED CURRENT

AUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC-1

C03

(24 VDC)

C12

(110 VDC)

C15

(220 VDC)

CWC07-10-30 3 7 18

1NO 10534754 10534770 10075918 333,00

CWC07-01-30 1NC 10534755 10534771 10075919 368,00

CWC09-10-30 4 9 20

1NO 10534756 10534772 10047052 368,00

CWC09-01-30 1NC 10534757 10534773 10075920 370,00

CWC012-10-30 5.5 12 22

1NO 10534758 10534774 10075921 370,00

CWC012-01-30 1NC 10534759 10534775 10075922 394,00

CWC016-10-30 7.5 16 22

1NO 10534760 10534776 10212764 394,00

CWC016-01-30 1NC 10534761 10534777 10647776 394,00

COMPACT CONTACTORS CWC0 - 7 TO 16 A - DC COIL - STANDARD CONSUMPTION

Note : 1) Upon Request.

- Smart code of the rated voltage.

Page 41: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

78 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 79

3-Pole Compact Contactors

COMPACT CONTACTORS CWC0 - SCREW TYPE

TYPERATED POWER

AC-3 / 400 V (kW)

RATED CURRENT

AUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC-1L03 (24 VDC) L12 (110 VDC) L15 (220 VDC)

CWC07-10-30 3 7 18

1NO 10694577 10695623 10695626 339,00

CWC07-01-30 1NC 10695681 10695685 10695627 339,00

CWC09-10-30 4 9 20

1NO 10696861 10696859 10696860 376,00

CWC09-01-30 1NC 10696856 10696858 10696857 376,00

CWC012-10-30 5.5 12 22

1NO 10696863 10696865 10696864 377,00

CWC012-01-30 1NC 10696869 10696866 10696868 377,00

CWC016-10-30 7.5 16 22

1NO 10695687 10696851 10696852 402,00

CWC016-01-30 1NC 10696855 10696854 10696853 402,00

TYPERATED POWER

AC-3 / 400 V (kW)

RATED CURRENT

AUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC-1R03 (24 VDC) R12 (110 VDC) R15 (220 VDC)

CWC07-10-30 3 7 18

1NO Upon request 2) Upon request 2) Upon request 2) Upon Request

CWC07-01-30 1NC Upon request 2) Upon request 2) Upon request 2) Upon Request

CWC09-10-30 4 9 20

1NO Upon request 2) Upon request 2) Upon request 2) Upon Request

CWC09-01-30 1NC Upon request 2) Upon request 2) Upon request 2) Upon Request

CWC012-10-30 5.5 12 22

1NO Upon request 2) Upon request 2) Upon request 2) Upon Request

CWC012-01-30 1NC Upon request 2) Upon request 2) Upon request 2) Upon Request

CWC016-10-30 7.5 16 22

1NO Upon request 2) Upon request 2) Upon request 2) Upon Request

CWC016-01-30 1NC Upon request 2) Upon request 2) Upon request 2) Upon Request

COMPACT CONTACTORS CWC0 - 7 TO 16 A - 0.75 X UC - DC COIL - STANDARD CONSUMPTION

COMPACT CONTACTORS CWC0 - 7 TO 16 A - DC COIL - LOW CONSUMPTION 1)

Note : 1) Auxiliary block front mounting available at a maximum of 2 contacts.

2) Upon Request.

- Smart code of the rated voltage.

COMPACT CONTACTORS CWCI0 - SCREW TYPE

TYPE

RATED CURRENT

Ie

AC-3

AUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)D02 (24 V) D13 (110 V) D24 (230 V) D34 (400 V)

CWCI07-10-30 7 1NO Upon request 1) 10651707 10075391 10075392 598,00

CWCI07-01-30 7 1NC 11783396 10651164 10651705 10075393 598,00

CWCI09-10-30 9 1NO 10076316 10651764 10075394 10075395 641,00

CWCI09-01-30 9 1NC 10651759 10651884 10649268 10075396 641,00

CWCI012-10-30 12 1NO Upon request 1) 10658857 10075397 10075398 658,00

CWCI012-01-30 12 1NC 10075713 10658753 10649259 10075399 658,00

CWCI016-10-30 16 1NO 10749214 10658957 10075400 10075401 681,00

CWCI016-01-30 16 1NC 10075714 10658955 10649388 10075402 681,00

TYPE

RATED CURRENT

Ie

AC-3

AUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)C03 (24 VDC) C12 (110 VDC) C15 (220 VDC)

CWCI07-10-30 7 1NO 10534818 10534834 10075947 745,00

CWCI07-01-30 7 1NC 10534819 10534835 10075948 745,00

CWCI09-10-30 9 1NO 10534820 10534836 10075949 817,00

CWCI09-01-30 9 1NC 10534821 10534837 10075950 817,00

CWCI012-10-30 12 1NO 10534822 10534838 10534838 821,00

CWCI012-01-30 12 1NC 10534823 10534839 10075952 821,00

CWCI016-10-30 16 1NO 10534824 10534840 10075953 870,00

CWCI016-01-30 16 1NC 10534825 10534841 10075954 870,00

COMPACT CONTACTORS CWCI0 WITH MECHANICAL INTERLOCK - 7 TO 16 A - AC COIL

COMPACT CONTACTORS CWCI0 WITH MECHANICAL INTERLOCK - 7 TO 16 A - DC COIL

Note : 1) Upon Request.

Auxiliary block front mounting available at a maximum of 2 contacts.

- Smart code of the rated voltage.

3-Pole Compact Contactors

Page 42: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

80 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 81

COMPACT CONTACTORS CWCH0 - SCREW TYPE

COMPACT CONTACTORS WITH LATCH BLOCK CWCH0 - 7 TO 16 A - AC COIL

COMPACT CONTACTORS WITH LATCH BLOCK CWCH0 - 7 TO 16 A - DC COIL

Note : Auxiliary block front mounting available at a maximum of 2 contacts.

- Smart code of the rated voltage.

TYPE

RATED CURRENT

Ie

AC-3

AUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)D13 (110 V) D24 (230 V) D34 (400 V)

CWCH07-10-30 7

1NO 11702193 10075419 10075420 502,00

CWCH07-01-30 1NC 11702192 10075421 10075422 502,00

CWCH09-10-30 9

1NO 11702195 10075423 10075424 536,00

CWCH09-01-30 1NC 11702194 10075425 10075426 536,00

CWCH012-10-30 12

1NO 11702197 10075427 10075428 550,00

CWCH012-01-30 1NC 11702196 10075429 10075430 550,00

CWCH016-10-30 16

1NO 11702259 10075431 10075432 568,00

CWCH016-01-30 1NC 11702258 10075433 10075434 568,00

TYPE

RATED CURRENT

Ie

AC-3

AUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)C03 (24 VDC) C12 (110 VDC) C15 (220 VDC)

CWCH07-10-30 5.6

1NO 10074402 10074410 10074418 609,00

CWCH07-01-30 1NC 10074403 10074411 10074419 609,00

CWCH09-10-30 7.2

1NO 10074404 10074412 10074420 665,00

CWCH09-01-30 1NC 10074405 10074413 10074421 665,00

CWCH012-10-30 9.6

1NO 10074406 10074414 10074422 668,00

CWCH012-01-30 1NC 10074407 10074415 10074423 668,00

CWCH016-10-30 12.8

1NO 10074408 10074416 10074424 706,00

CWCH016-01-30 1NC 10074409 10074417 10074425 706,00

3-Pole Compact Contactors

COMPACT CONTACTORS CWC0_I - SCREW TYPE

TYPERATED POWER

AC-3 / 400 V (kW)

RATED CURRENT

AUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC-1D13 (110 V) D24 (230 V) D34 (400 V)

CWC07-10-30 I3 7 18

1NO 10645876 10075403 10075404 373,00

CWC07-01-30 I 1NC 10651905 10075405 10075406 373,00

CWC09-10-30 I4 9 20

1NO 10658498 10075407 10075408 394,00

CWC09-01-30 I 1NC 10647775 10075409 10075410 394,00

CWC012-10-30 I5.5 12 22

1NO 10651956 10075411 10075412 403,00

CWC012-01-30 I 1NC 10648140 10075413 10075414 403,00

CWC016-10-30 I7.5 16 22

1NO 10651811 10075415 10075416 414,00

CWC016-01-30 I 1NC 10651716 10075417 10075418 414,00

TYPERATED POWER

AC-3 / 400 V (kW)

RATED CURRENT

AUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC-1L03 (24 V DC/CC) L12 (110 V DC/CC) L15 (220 V DC/CC)

CWC07-10-30 I3 7 18

1NO 10700726 10700739 10700748 446,00

CWC07-01-30 I 1NC 10700757 10700769 10700771 446,00

CWC09-10-30 I4 9 20

1NO 10702291 10702230 10702232 483,00

CWC09-01-30 I 1NC 10702233 10702234 10702235 483,00

CWC012-10-30 I6 12 22

1NO 10702237 10702248 10702249 484,00

CWC012-01-30 I 1NC 10702250 10702251 10702252 484,00

CWC016-10-30 I7,5 16 22

1NO 10702253 10702254 10702256 509,00

CWC016-01-30 I 1NC 10702288 10702289 10702290 509,00

COMPACT CONTACTORS FOR PRINTED CIRCUIT BOARD - 7 TO 16 A - AC COIL

COMPACT CONTACTORS FOR PRINTED CIRCUIT BOARD - 7 TO 16 A - DC COIL - LOW CONSUMPTION 1)

TYPERATED POWER

AC-3 / 400 V (kW)

RATED CURRENT

AUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC-1C03 (24 V DC/CC) C12 (110 V DC/CC) C15 (220 V DC/CC)

CWC07-10-30 I3 7 18

1NO 10534858 10535647 10075979 438,00

CWC07-01-30 I 1NC 10534859 10535648 10075980 438,00

CWC09-10-30 I4 9 20

1NO 10534860 10535649 10075981 473,00

CWC09-01-30 I 1NC 10534861 10535650 10075982 473,00

CWC012-10-30 I5.5 12 22

1NO 10534862 10535651 10075983 475,00

CWC012-01-30 I 1NC 10534863 10535652 10075984 475,00

CWC016-10-30 I7.5 16 22

1NO 10534864 10535653 10075985 499,00

CWC016-01-30 I 1NC 10534865 10535654 10075986 499,00

COMPACT CONTACTORS FOR PRINTED CIRCUIT BOARD - 7 TO 16 A - DC COIL - STANDARD CONSUMPTION

Note : 1) Auxiliary block front mounting available at a maximum of 2 contacts.

Article numbers for other rated voltages and frequencies upon request.

- Smart code of the rated voltage.

3-Pole Compact Contactors

Page 43: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

82 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 83

COMPACT CONTACTORS CWC0 - SPRING TYPE

TYPERATED POWER

AC-3 / 400 V (kW)

RATED CURRENT

AUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC-1D13 (110 V) D24 (230 V) D34 (400 V)

CWC07-10-30 S3 7 3

1NO 11702260 11702274 11702314 293,00

CWC07-01-30 S 1NC 11702261 11702275 11702315 293,00

CWC09-10-30 S4 9 4

1NO 11702264 11702276 11702316 316,00

CWC09-01-30 S 1NC 11702265 11702277 11702317 316,00

CWC012-10-30 S6 12 5.5

1NO 11702267 11573038 11702388 325,00

CWC012-01-30 S 1NC 11702272 11702313 11702390 325,00

TYPERATED POWER

AC-3 / 400 V (kW)

RATED CURRENT

AUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC-1C03 (24 VDC) C12 (110 VDC) C15 (220 VDC)

CWC07-10-30 S3 7 18

1NO 11505011 11505084 11505085 366,00

CWC07-01-30 S 1NC 11505013 11505086 11505087 366,00

CWC09-10-30 S4 9 20

1NO 11505014 11505108 11505109 405,00

CWC09-01-30 S 1NC 11505016 11505115 11505116 405,00

CWC012-10-30 S6 12 22

1NO 11505017 11505130 11505131 407,00

CWC012-01-30 S 1NC 11505038 11505132 11505133 407,00

TYPERATED POWER

AC-3 / 400 V (kW)

RATED CURRENT

AUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC-1L03 (24 VDC) L12 (110 VDC) L15 (220 VDC)

CWC07-10-30 S3 7 18

1NO 11505040 11505134 11505135 373,00

CWC07-01-30 S 1NC 11505041 11505136 11505148 373,00

CWC09-10-30 S4 9 20

1NO 11505043 11505150 11505152 413,00

CWC09-01-30 S 1NC 11505044 11505153 11505156 413,00

CWC012-10-30 S6 12 22

1NO 11505045 11505179 11505181 415,00

CWC012-01-30 S 1NC 11505046 11505184 11505185 415,00

TYPERATED POWER

AC-3 / 400 V (kW)

RATED CURRENT

AUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC-1R03 (24 VDC) R12 (110 VDC) R15 (220 VDC)

CWC07-10-30 S3 7 18

1NO Upon request 1) Upon request 1) Upon request 1) Upon request

CWC07-01-30 S 1NC Upon request 1) Upon request 1) Upon request 1) Upon request

CWC09-10-30 S4 9 20

1NO Upon request 1) Upon request 1) Upon request 1) Upon request

CWC09-01-30 S 1NC Upon request 1) Upon request 1) Upon request 1) Upon request

CWC012-10-30 S6 12 22

1NO Upon request 1) Upon request 1) Upon request 1) Upon request

CWC012-01-30 S 1NC Upon request 1) Upon request 1) Upon request 1) Upon request

COMPACT CONTACTORS CWC0_S - 7 TO 12 A - AC COIL

COMPACT CONTACTORS CWC0_S - 7 TO 12 A - DC COIL - STANDARD CONSUMPTION

COMPACT CONTACTORS CWC0_S - 7 TO 12 A - DC COIL - LOW CONSUMPTION

COMPACT CONTACTORS CWC0_S - 7 TO 12 A - 0.75 X UC - DC COIL - STANDARD CONSUMPTION

Note : 1) Upon Request.

3-Pole Compact Contactors

COMPACT CONTACTORS CWCI0 - SPRING TYPE

TYPE

RATED CURRENT

Ie

AC-3

AUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)D13 (24 V) D24 (230 V) D34 (400 V)

CWCI07-10-30 S 7 1NO 11702732 11702762 11702800 658,00

CWCI07-01-30 S 7 1NC 11702733 11702763 11702801 658,00

CWCI09-10-30 S 9 1NO 11702737 11702764 11702803 705,00

CWCI09-01-30 S 9 1NC 11702758 11702765 11702804 705,00

CWCI012-10-30 S 12 1NO 11702759 11702766 11702805 724,00

CWCI012-01-30 S 12 1NC 11702761 11702798 11702806 724,00

TYPE

RATED CURRENT

Ie

AC-3

AUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)C03 (24 V DC/CC) C12 (110 V DC/CC) C15 (220 V DC/CC)

CWCI07-10-30 S 7 1NO 11505255 11505273 11505297 820,00

CWCI07-01-30 S 7 1NC 11505256 11505339 11505343 820,00

CWCI09-10-30 S 9 1NO 11505268 11505345 11505347 899,00

CWCI09-01-30 S 9 1NC 11505269 11505368 11505370 899,00

CWCI012-10-30 S 12 1NO 11505270 11505371 11505372 903,00

CWCI012-01-30 S 12 1NC 11505271 11505373 11505374 903,00

COMPACT CONTACTORS CWCI0_S WITH MECHANICAL INTERLOCK - 7 TO 12 A - AC COIL

COMPACT CONTACTORS CWCI0_S WITH MECHANICAL INTERLOCK - 7 TO 12 A - DC COIL

Note : - Smart code of the rated voltage.

3-Pole Compact Contactors

Page 44: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

84 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 85

COMPACT CONTACTORS CWCH0 - SPRING TYPE

COMPACT CONTACTORS WITH LATCH BLOCK CWCH0_S - 7 TO 12 A - AC COIL

TYPE

RATED CURRENT

Ie

AC-3

AUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)D13 (110 V) D24 (230 V) D34 (400 V)

CWCH07-01-30 S7

1NO 11703016 11703026 11703063 552,00

CWCH07-10-30 S 1NC 11703015 11703024 11703062 552,00

CWCH09-01-30 S9

1NO 11703020 11703059 11703065 589,00

CWCH09-10-30 S 1NC 11703019 11703027 11703064 589,00

CWCH012-01-30 S12

1NO 11703023 11703061 11703067 605,00

CWCH012-10-30 S 1NC 11703022 11703060 11703066 605,00

Note : Auxiliary block front mounting available at a maximum of 2 contacts.

- Smart code of the rated voltage.

COMPACT CONTACTORS WITH LATCH BLOCK CWCH0_S - 7 TO 12 A - DC COIL

TYPE

RATED CURRENT

Ie

AC-3

AUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)C03 (24 V DC/CC) C12 (110 V DC/CC) C15 (220 V DC/CC)

CWCH07-10-30 S7

1NO 11505799 11505880 11505882 670,00

CWCH07-01-30 S 1NC 11505801 11505883 11505885 670,00

CWCH09-10-30 S9

1NO 11505802 11505887 11505898 732,00

CWCH09-01-30 S 1NC 11505803 11505900 11505902 732,00

CWCH012-10-30 S12

1NO 11505804 11505903 11505905 735,00

CWCH012-01-30 S 1NC 11505805 11505907 11505918 735,00

3-Pole Compact Contactors Accessories for Compact Contactors

ACCESSORIES FOR COMPACT CONTACTORS CWC0

ON-DELAY ELECTRONIC TIMER BLOCK

TYPE SUPPLY VOLTAGE TIMING STOCK CODEPRICE EACH

(ZAR)

TEC0-U003S-E05

E05

24-240 VAC / VDC

0.3s...3s 10047140 871,00

TEC0-U010S-E05 1s...10s 10074476 871,00

TEC0-U030S-E05 3s...30s 10186750 871,00

TEC0-U060S-E05 6s...60s 10186751 871,00

TEC0-U100S-E05 10s...100s 10074477 871,00

TEC0-U300S-E05 30s...300s 10074478 871,00

TEC0-U030M-E05 3min...30min 10694019 871,00

OFF-DELAY ELECTRONIC TIMER BLOCK

TYPE SUPPLY VOLTAGE TIMING STOCK CODEPRICE EACH

(ZAR)

TDC0-U003S-E09

E09

100-240 VAC / VDC

0.3s...3s 10694023 1127,00

TDC0-U010S-E09 1s...10s 10074486 1127,00

TDC0-U030S-E09 3s...30s 10694026 1127,00

TDC0-U060S-E09 6s...60s 10074487 1127,00

TDC0-U100S-E09 10s...100s 10074488 1127,00

TDC0-U300S-E09 30s...300s 10074489 1127,00

TDC0-U030M-E09 3min...30min 10694048 1127,00

STAR-DELTA ELECTRONIC TIMER BLOCK

TYPE SUPPLY VOLTAGE TIMING STOCK CODEPRICE EACH

(ZAR)

TETC0-U030S-D52 24-28 VAC 3s...30s 10074490 902,00

TETC0-U030S-D61 110-130 VAC 3s...30s 10694005 902,00

TETC0-U030S-D66 220-240 VAC 3s...30s 10047141 902,00

OFF-DELAY ELECTRONIC TIMER BLOCK

TYPE SUPPLY VOLTAGE TIMING STOCK CODEPRICE EACH

(ZAR)

TDC0-U003S-E04

E04

24-60 VAC / VDC

0.3s...3s 10074479 1127,00

TDC0-U010S-E04 1s...10s 10074480 1127,00

TDC0-U030S-E04 3s...30s 10074481 1127,00

TDC0-U060S-E04 6s...60s 10074482 1127,00

TDC0-U100S-E04 10s...100s 10074483 1127,00

TDC0-U300S-E04 30s...300s 10074484 1127,00

TDC0-U030M-E04 3min...30min 10074485 1127,00

Page 45: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

86 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 87

Accessories for Compact Contactors

ACCESSORIES FOR COMPACT CONTACTORS CWC0

AUXILIARY CONTACT BLOCK - SCREW TYPE

TYPE MOUNTING TO USE WITH AUX.CONTACT STOCK CODEPRICE EACH

(ZAR)

BFC0-20

Frontal

CWC0

3-Pole

2-Pole

2NO 10047053 105,00

BFC0-11 1NO + 1NC 10047054 105,00

BFC0-02 2NC 10047055 105,00

BFC0-40 4NO 10047056 165,00

BFC0-22 2NO + 2NC 10561730 165,00

BFC0-04 1) 4NC 10047057 165,00

BFC0-31 3NO + 1NC 10047058 165,00

BFC0-13 1) 1NO + 3NC 10047059 165,00

BFC025-20

Frontal

CWC025

3-Pole

2-Pole

2NO / 2NA 10682155 105,00

BFC025-11 1NO + 1NC 10667309 105,00

BFC025-02 2NC 10682150 105,00

BFC025-22Z 2NO + 2NC 11104845 165,00

BFC4-20

FrontalCWC0

4-Pole

2NO / 2NA 10075664 105,00

BFC4-11 1NO + 1NC 10075665 105,00

BFC4-02 2NC 10075666 105,00

BFC4-40 4NO 10047368 165,00

BFC4-22 2NO + 2NC 10075667 165,00

BFC4-04 1) 4NC 10075668 165,00

BFC4-31 3NO + 1NC 10212740 165,00

BFC4-13 1) 1NO + 3NC 10075669 165,00

BFCA-20

FrontalCWCA0

Relay

2NO 10186982 105,00

BFCA-11 1NO + 1NC 10047366 105,00

BFCA-02 2NC 10047367 105,00

BFCA-40 4NO 10047369 165,00

BFCA-22 2NO + 2NC 10410465 165,00

BFCA-04 1) 4NC 10441421 165,00

BFCA-31 3NO + 1NC 10075670 165,00

BFCA-13 1) 1NO + 3NC 10047370 165,00

Note : 1) The auxiliary contact blocks with configurations “-13” or “-04” only must be used in compact contactors with AC coil or 0.75xUc DC coil.

Accessories for Compact Contactors

ACCESSORIES FOR COMPACT CONTACTORS CWC0

AUXILIARY CONTACT BLOCK - SPRING TYPE

TYPE MOUNTING TO USE WITH AUX. CONTACT STOCK CODEPRICE EACH

(ZAR)

BFC0-20S

Frontal

CWC0

3-Pole

2-Pole

2NO 11507487 115,00

BFC0-11S 1NO + 1NC 11507498 115,00

BFC0-02S 2NC 11507500 115,00

BFC0-40S 4NO 11507501 182,00

BFC0-22S 2NO + 2NC 11507502 182,00

BFC0-04S 1) 4NC 11507503 182,00

BFC0-31S 3NO + 1NC 11507504 182,00

BFC0-13S 1) 1NO + 3NC 11507505 182,00

BFC4-20S

FrontalCWC0

4-Pole

2NO 11507506 115,00

BFC4-11S 1NO + 1NC 11507507 115,00

BFC4-02S 2NC 11507528 115,00

BFC4-40S 4NO 11507511 182,00

BFC4-22S 2NO + 2NC 11507529 182,00

BFC4-04S 1) 4NC 11507510 182,00

BFC4-31S 3NO + 1NC 11507530 182,00

BFC4-13S 1) 1NO + 3NC 11507532 182,00

BFCA-20S

FrontalCWCA0

Relay

2NO 11507513 113,00

BFCA-11S 1NO + 1NC 11507533 113,00

BFCA-02S 2NC 11507534 113,00

BFCA-40S 4NO 11507514 182,00

BFCA-22S 2NO + 2NC 11507535 182,00

BFCA-04S 1) 4NC 11507517 182,00

BFCA-31S 3NO + 1NC 11507536 182,00

BFCA-13S 1) 1NO + 3NC 11507548 182,00

Note : 1) The auxiliary contact blocks with configurations “-13” or “-04” only must be used in compact contactors with AC coil or 0.75xUc DC coil.

Page 46: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

88 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 89

Accessories for Compact Contactors

ACCESSORIES FOR COMPACT CONTACTORS CWC0

SURGE SUPPRESSOR BLOCK

TYPE MOUNTING RATED VOLTAGE STOCK CODEPRICE EACH

(ZAR)

RCC0-1 D49

Frontal

12-24 V 50/60 Hz 10047061 104,00

RCC0-2 D53 24-48 V 50/60 Hz 10047062 104,00

RCC0-3 D55 48-127 V 50/60 Hz 10047063 104,00

RCC0-4 D63 127-250 V 50/60 Hz 10047064 104,00

RCC0-5 D84 250-380 V 50/60 Hz 10047065 104,00

RCC0-6 D73 380-510 V 50/60 Hz 10047066 104,00

RCAC0 D87 180-230 V 50/60 Hz 11178695 104,00

VRC0-1 E49 12-48 VAC / 12-60 VDC 10047067 104,00

VRC0-2 E34 50-127 VAC / 60-180 VDC 10047068 104,00

VRC0-3 E50 130-275 VAC / 180-300 VDC 10047069 104,00

VRC0-4 E41 277-380 VAC / 300-510 VDC 10047070 104,00

VRC0-5 D73 400-510 V 50/60 Hz 10047071 104,00

DIC0-1 C33 12-600 VDC 10047072 104,00

DIZC0 C26 12-250 VDC 11157963 104,00

PRINTED CIRCUIT BOARD CONNECTOR

MECHANICAL INTERLOCK BLOCK

BUS BAR SYSTEM - EASY CONNECTION KIT

LATCH BLOCK

TYPE STOCK CODEPRICE EACH

(ZAR)

CIC0 10075988 102,00

TYPE CONTACTORS MOUNTING STOCK CODE PRICE EACH (ZAR)

BIC0 CWC07-016 Front 10047060 64,00

TYPE STARTERS STOCK CODEPRICE EACH

(ZAR)

ECC0-R Reversing power and control circuits 10047150 276,00

ECC0-RNI Reversing - power circuit 11788681 297,00

ECC0-SD Star-delta power and control 10047151 309,00

TYPE STOCK CODEPRICE EACH

(ZAR)

RMC0 10075987 74,00

Accessories for Compact Contactors

ACCESSORIES FOR COMPACT CONTACTORS CWC0

SPARE CONTACTS FOR 3-POLE MINICONTACTOR

COMPACT CONTACTORS AC

TYPE CONTACTORS STOCK CODEPRICE EACH

(ZAR)

JCC07-3P.10 CWC07-10 10212766 140,00

JCC07-3P.01 CWC07-01 10212767 140,00

JCC09-10 CWC09-10 10452888 151,00

JCC09-3P.01 CWC09-01 10212768 151,00

JCC012-3P.10 CWC012-10 10212769 155,00

JCC012-3P.01 CWC012-01 10212770 155,00

JCC016-10 CWC016-10 10682153 161,00

JCC016-3P.01 CWC016-01 10212771 161,00

JCC025-3P CWC025-00 10664242 203,00

TYPE CONTACTOR STOCK CODEPRICE EACH

(ZAR)

JCCB07-3P.10 CWC07-10 10212395 140,00

JCCB07-3P.01 CWC07-01 10212396 140,00

JCCB09-3P.10 CWC09-10 10212397 151,00

JCCB09-3P.01 CWC09-01 10212398 151,00

JCCB012-3P.10 CWC012-10 10212399 155,00

JCCB012-3P.01 CWC012-01 10212400 155,00

JCCB016-3P.10 CWC016-10 10212401 161,00

JCCB016-3P.01 CWC016-01 10212402 161,00

AC COILS - 50/60Hz

TYPE VAC STOCK CODEPRICE EACH

(ZAR)

BRC-016D13 110 10213231 89,00

BRC-016D24 230 10047168 89,00

BRC-016D34 400 10075435 89,00

BRC-025D13 110 11141639 112,00

BRC-025D24 230 11141641 112,00

BRC-025D34 400 11141646 112,00

TYPE VDC STOCK CODEPRICE EACH

(ZAR)

BRC-016C03 24 10075989 215,00

BRC-016C12 110 10075990 215,00

BRC-016C15 220 10075991 215,00

TYPE VDC STOCK CODEPRICE EACH

(ZAR)

BRC-016R03 24 10726838 215,00

BRC-016R12 110 10261571 215,00

BRC-016R15 220 10261572 215,00

TYPE VDC STOCK CODEPRICE EACH

(ZAR)

BRC-016L03 24 10726841 215,00

BRC-016L12 110 10726869 215,00

BRC-016L15 220 10726873 215,00

Note : Article numbers for other rated voltages and frequencies upon request.

COMPACT CONTACTORS DC

DC COILS - STANDARD CONSUMPTION

DC COILS FOR 4 - POLE MINICONTACTORS 2P/2R (2NO +2NC)

DC COILS - LOW CONSUMPTION

Page 47: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

90 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 91

Control Relays

CONTROL RELAYS CWCA0 - SCREW TYPE

TYPE Ith

Ie

AC-15 / 220 VAUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)D02 (24 V) D13 (110 V) D24 (230 V) D34 (400 V)

CWCA0-22-00

10 10

2NO + 2NC 10047362 10410620 10047169 10075450 266,00

CWCA0-31-00 3NO + 1NC 10047363 10047461 10047170 10075451 266,00

CWCA0-13-00 1NO + 3NC 10047361 10047506 10047171 10075452 266,00

CWCA0-40-00 4NO 10047364 10047460 10047172 10075453 266,00

CWCA0-04-00 4NC 10047360 10047507 10647292 10075454 266,00

CONTROL RELAYS CWCA0 - AC COIL

TYPE Ith

Ie

AC-15 / 220 VAUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)C03 (24 V DC/CC) C12 (110 V DC/CC) C15 (220 V DC/CC)

CWCA0-22-00

10 10

2NO + 2NC 10047079 10410416 10075999 333,00

CWCA0-31-00 3NO + 1NC 10047080 10047081 10648112 333,00

CWCA0-13-00 1NO + 3NC 10047082 10076000 10076001 333,00

CWCA0-40-00 4NO 10047083 10047084 10186694 333,00

CWCA0-04-00 4NC 10047085 10076002 10076003 333,00

CONTROL RELAYS CWCA0 - DC COIL - STANDARD CONSUMPTION

TYPE Ith

Ie

AC-15 / 220 VAUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)L03 (24 V DC/CC) L12 (110 V DC/CC) L15 (220 V DC/CC)

CWCA0-22-00

10 10

2NO + 2NC 10697325 10697323 10697324 339,00

CWCA0-31-00 3NO + 1NC 10697318 10697322 10697321 339,00

CWCA0-13-00 1NO + 3NC 10697277 10697270 10697274 339,00

CWCA0-40-00 4NO 10697123 10697231 10697125 339,00

CWCA0-04-00 4NC 10697184 10697268 10697181 339,00

CONTROL RELAYS CWCA0 - DC COIL - LOW CONSUMPTION

TYPE Ith

Ie

AC-15 / 220 VAUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)R03 (24 V DC/CC) R12 (110 V DC/CC) R15 (220 V DC/CC)

CWCA0-22-00

10 10

2NO + 2NC Upon request 2) Upon request 2) Upon request 2) Upon request

CWCA0-31-00 3NO + 1NC Upon request 2) Upon request 2) Upon request 2) Upon request

CWCA0-13-00 1NO + 3NC Upon request 2) Upon request 2) Upon request 2) Upon request

CWCA0-40-00 4NO Upon request 2) Upon request 2) Upon request 2) Upon request

CWCA0-04-00 4NC Upon request 2) Upon request 2) Upon request 2) Upon request

CONTROL RELAYS CWCA0 - 0.75 X UC DC COIL - STANDARD CONSUMPTION

Note : 1) Auxiliary block front mounting available at a maximum of 2 contacts.

2) Upon Request.

Article numbers for other rated voltages and frequencies upon request.

- Smart code of the rated voltage.

CONTROL RELAYS CWCHA0 - SCREW TYPE

TYPE Ith

Ie

AC-15 / 220 VAUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)D13 (110 V) D24 (230 V) D34 (400 V)

CWCHA0-22-00

10 10

2NO + 2NC 11703472 11703475 11703498 502,00

CWCHA0-31-00 3NO + 1NC 11703473 11703476 11703500 502,00

CWCHA0-40-00 4NO 11703474 11703477 11703501 502,00

CONTROL RELAYS WITH LATCH BLOCK CWCHA0 - AC COIL

TYPE Ith

Ie

AC-15 / 220 VAUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)C03 (24 V DC/CC) C12 (110 V DC/CC) C15 (220 V DC/CC)

CWCHA0-22-00

10 10

2NO + 2NC 11516227 11516278 11516279 609,00

CWCHA0-31-00 3NO + 1NC 11516224 11516225 11516226 609,00

CWCHA0-40-00 4NO 11516218 11516219 11516220 609,00

CONTROL RELAYS WITH LATCH BLOCK CWCHA0 - DC COIL

Note : Article numbers for other rated voltages and frequencies upon request.

- Smart code of the rated voltage.

Control Relays

Page 48: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

92 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 93

Control Relays

CONTROL RELAYS CWCA0 - SPRING TYPE

CONTROL RELAYS CWCA0_S - AC COIL

TYPE Ith

Ie

AC-15 / 220 VAUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)D13 (110 V) D24 (230 V) D34 (400 V)

CWCA0-22-00 S

10 10

2NO + 2NC 11703503 11703531 11703536 293,00

CWCA0-31-00 S 3NO + 1NC 11703504 11703532 11703537 293,00

CWCA0-13-00 S 1NO + 3NC 11703505 11703533 11703568 293,00

CWCA0-40-00 S 4NO 11703507 11703534 11703569 293,00

CWCA0-04-00 S 4NC 11703529 11703535 11703570 293,00

CONTROL RELAYS CWCA0_S - 0.75 X UC DC COIL - STANDARD CONSUMPTION

TYPE Ith

Ie

AC-15 / 220 VAUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)R03 (24 VDC) R12 (110 VDC) R15 (220 VDC)

CWCA0-22-00 S

10 10

2NO + 2NC Upon request 2) Upon request 2) Upon request 2) Upon request

CWCA0-31-00 S 3NO + 1NC Upon request 2) Upon request 2) Upon request 2) Upon request

CWCA0-13-00 S 1NO + 3NC Upon request 2) Upon request 2) Upon request 2) Upon request

CWCA0-40-00 S 4NO Upon request 2) Upon request 2) Upon request 2) Upon request

CWCA0-04-00 S 4NC Upon request 2) Upon request 2) Upon request 2) Upon request

CONTROL RELAYS CWCA0_S - DC COIL - STANDARD CONSUMPTION

TYPE Ith

Ie

AC-15 / 220 VAUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)L03 (24 VDC) L12 (110 VDC) L15 (220 VDC)

CWCA0-22-00 S

10 10

2NO + 2NC 11505866 11505961 11505962 366,00

CWCA0-31-00 S 3NO + 1NC 11505869 11505963 11505965 366,00

CWCA0-13-00 S 1NO + 3NC 11505870 11505966 11505967 366,00

CWCA0-40-00 S 4NO 11505871 11505989 11505990 366,00

CWCA0-04-00 S 4NC 11505873 11505991 11505993 366,00

CONTROL RELAYS CWCA0_S - DC COIL - LOW CONSUMPTION 1)

TYPE Ith

Ie

AC-15 / 220 VAUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)R03 (24 VDC) R12 (110 VDC) R15 (220 VDC)

CWCA0-22-00 S

10 10

2NO + 2NC 11505874 11505995 11506015 373,00

CWCA0-31-00 S 3NO + 1NC 11505876 11505996 11506017 373,00

CWCA0-13-00 S 1NO + 3NC 11505877 11506008 11506028 373,00

CWCA0-40-00 S 4NO 11505878 11506010 11506029 373,00

CWCA0-04-00 S 4NC 11505879 11506011 11506030 373,00

Note : Article numbers for other rated voltages and frequencies upon request.

Note : 1) Auxiliary block front mounting available at a maximum of 2 contacts.

2) Upon Request.

- Smart code of the rated voltage.

2-Pole Contactors

2-POLE CONTACTORS “CWC0” - 7 TO 22A - AC COIL

TYPERATED POWER

AC-3 /400 V (kW)

RATED CURRENTMAIN

CONTACTS

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

ITH

AC- 1D13 (110 V) D24 (230 V) D34 (400 V)

CWC07-00-20 3 7 18 2NO 11063855 10867119 10867120 226,00

CWC07-00-02 3 7 18 2NC Upon request 1) 10867121 10867122 226,00

CWC09-00-20 4 9 20 2NO 11063856 10867124 10867125 244,00

CWC09-00-02 4 9 20 2NC Upon request 1) 10867158 10867126 244,00

CWC012-00-20 5,5 12 22 2NO 11063879 10867162 10867163 251,00

CWC012-00-02 5,5 12 22 2NC Upon request 1) 10867159 10867161 251,00

CWC016-00-20 7,5 16 22 2NO 11063881 10867164 10867165 261,00

CWC016-00-02 7,5 16 22 2NC Upon request 1) 10867166 10867167 261,00

CWC025-00-20 11 22 32 2NO 11483761 10867198 10867199 329,00

2-POLE CONTACTORS “CWM” - 7 TO 105A - AC COIL

TYPERATED POWER

AC-3 /400 V (kW)

RATED CURRENTMAIN

CONTACTS

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC- 1D13 (110 V) D24 (230 V) D34 (400 V)

CWM9-00-20 3,7 9 25 2NO 10652833 10867206 10867218 271,00

CWM9-00-02 3,7 9 25 2NC Upon request 1) 10867220 10867221 271,00

CWM12-00-20 5,5 12 25 2NO 10647989 10867222 10867224 286,00

CWM12-00-02 5,5 12 25 2NC Upon request 1) 10867226 10867227 286,00

CWM18-00-20 7,5 18 32 2NO 10650330 10669711 10867238 307,00

CWM18-00-02 7,5 18 32 2NC Upon request 1) 10867239 10867240 307,00

CWM25-00-20 11 25 45 2NO 10071587 10668523 10867242 439,00

CWM25-00-02 11 25 45 2NC Upon request 1) 10076888 10867243 439,00

CWM32-00-20 15 32 60

2NO

10073495 10867244 10867245 656,00

CWM40-00-20 70,5 40 60 10073501 10867246 10867247 732,00

CWM50-00-20 22 50 90 10073507 10867248 10867249 1238,00

CWM65-00-20 30 65 110 10073513 10867250 10867251 1426,00

CWM80-00-20 37 80 110 10073519 10867252 10867253 1502,00

CWM95-00-20 45 95 140 10073524 10867254 10867255 2041,00

CWM105-00-20 55 105 140 10073530 10867256 10867257 2236,00

2-POLE CONTACTORS “CWC0” - 7 TO 12A - AC COIL

TYPERATED POWER

AC-3 /400 V (kW)

RATED CURRENTMAIN

CONTACTS

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC- 1D13 (110 V) D24 (230 V) D34 (400 V)

CWC07-00-20 S 3 7 18 2NO 11705706 11705714 11705721 249,00

CWC07-00-02 S 3 7 18 2NC 11705707 11705715 11705722 249,00

CWC09-00-20 S 4 9 20 2NO 11705708 11705716 11705723 268,00

CWC09-00-02 S 4 9 20 2NC 11705709 11705717 11705724 268,00

CWC012-00-20 S 5,5 12 22 2NO 11705711 11705718 11705725 276,00

CWC012-00-02 S 5,5 12 22 2NC 11705712 11705720 11705726 276,00

Note : 1) Upon Request.

- Smart code of the rated voltage.

Page 49: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

94 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 95

4-Pole Contactors

4-POLE COMPACT CONTACTORS CWC0 - SCREW TYPE

4-POLE COMPACT CONTACTORS - “CWC0” 7 TO 16A - AC COIL

TYPERATED POWER

AC-3 /400 V (kW)

RATED CURRENTMAIN

CONTACTS

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC- 1D02 (24 V) D13 (110 V) D24 (230 V) D34 (400 V)

CWC07-00-40 3 7 18

4NO

10075654 10646258 10075436 10075437 277,00

CWC09-00-40 4 9 20 10075655 10075657 10648721 10075438 300,00

CWC012-00-40 5,5 12 22 10075650 10648470 10075439 10075440 314,00

CWC016-00-40 7,5 16 22 10075652 10648664 10186768 10075441 327,00

CWC07-00-22 3 7 18

2NO + 2NC

10075653 10646202 10075442 10075443 277,00

CWC09-00-22 4 9 20 10047359 10648388 10075444 10075445 300,00

CWC012-00-22 5,5 12 22 10075649 10187773 10075446 10075447 314,00

CWC016-00-22 7,5 16 22 10075651 10648628 10075448 10075449 327,00

4-POLE CONTACTORS - “CWC0” 7 TO 16A - DC COIL - STANDARD CONSUMPTION

TYPERATED POWER

AC-3 /400 V (kW)

RATED CURRENTMAIN

CONTACTS

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC- 1C03 (24 VDC) C12 (110 VDC) C15 (220 VDC)

CWC07-00-40 3 7 18

4NO

10534790 10534798 10076027 275,00

CWC09-00-40 4 9 20 10534791 10534799 10076028 305,00

CWC012-00-40 5,5 12 22 10534792 10534800 10076029 311,00

CWC016-00-40 7,5 16 22 10534793 10534801 10076030 333,00

4-POLE CONTACTORS - “CWC0” - DC COIL - LOW CONSUMPTION 1)

TYPERATED POWER

AC-3 /400 V (kW)

RATED CURRENTMAIN

CONTACTS

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC- 1L03 (24 VDC) L12 (110 VDC) L15 (220 VDC)

CWC07-00-40 3 7 18

4NO

10710069 10710071 10710077 353,00

CWC09-00-40 4 9 20 10710092 10710095 10710096 392,00

CWC012-00-40 5,5 12 22 10710097 10710098 10710100 400,00

CWC016-00-40 7,5 16 22 10710101 10710102 10710103 428,00

Note : 1) Auxiliary block front mounting available at a maximum of 2 contacts.

- Smart code of the rated voltage.

4-POLE CONTACTORS - “CWC0 - 7 TO 16A 75% DC COIL - STANDARD CONSUMPTION

TYPERATED POWER

AC-3 /400 V (kW)

RATED CURRENTMAIN

CONTACTS

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC- 1R03 (24 VDC) R12 (110 VDC) R15 (220 VDC)

CWC07-00-22 3 7 18

2NO + 2NC

10261060 10261068 10076033 346,00

CWC09-00-22 4 9 20 10261061 10261069 10074897 384,00

CWC012-00-22 5,5 12 22 10261062 10261070 10074900 392,00

CWC016-00-22 7,5 16 22 10261063 10261071 10074903 420,00

Note : For applications where there is a significant reduction on the rated voltage, sometimes due to long distances or network problems.

4-Pole Contactors

4-POLE COMPACT CONTACTORS CWC0 - SPRING TYPE

4-POLE COMPACT CONTACTORS - “CWC0” - 7 TO 12A - AC COIL

TYPERATED POWER

AC-3 /400 V (kW)

RATED CURRENTMAIN

CONTACTS

Ie

AC-1 (A)

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC- 1D13 (110 V) D24 (230 V) D34 (400 V)

CWC07-00-40 S 3 7 18

4NO

18 11703576 11703611 11703617 304,00

CWC09-00-40 S 4 9 20 20 11703574 11703612 11703628 330,00

CWC012-00-40 S 5,5 12 22 22 11703573 11573039 11703630 345,00

CWC07-00-22 S 3 7 18

2NO + 2NC

18 11703577 11703613 11703631 304,00

CWC09-00-22 S 4 9 20 20 11703608 11703614 11703632 330,00

CWC012-00-22 S 5,5 12 22 22 11703609 11703615 11703633 345,00

4-POLE CONTACTORS - “CWC0” - 7 TO 12A - DC COIL - STANDARD CONSUMPTION

TYPERATED POWER

AC-3 /400 V (kW)

RATED CURRENTMAIN

CONTACTS

Ie

AC-1 (A)

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC- 1C03 (24 VDC) C12 (110 VDC) C15 (220 VDC)

CWC07-00-40 S 3 7 18

4NO

18 11646516 11646517 11646558 381,00

CWC09-00-40 S 4 9 20 20 11646559 11646560 11646561 423,00

CWC012-00-40 S 5,5 12 22 22 11646562 11646563 11646564 431,00

4-POLE COMPACT CONTACTORS - “CWC0” 7 TO 12A -75% DC COIL - LOW CONSUMPTION 1)

TYPERATED POWER

AC-3 /400 V (kW)

RATED CURRENTMAIN

CONTACTS

Ie

AC-1 (A)

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC- 1L03 (24 VDC) L12 (110 VDC) L15 (220 VDC)

CWC07-00-40 S 3 7 18

4NO

18 11646565 11646578 11646581 388,00

CWC09-00-40 S 4 9 20 20 11646566 11646579 11646582 431,00

CWC012-00-40 S 5,5 12 22 22 11646567 11646580 11646583 440,00

Note : 1) Auxiliary block front mounting available at a maximum of 2 contacts.

- Smart code of the rated voltage.

4-POLE CONTACTORS - “CWC0” 7 TO 12A - 75% DC COIL - STANDARD CONSUMPTION

TYPERATED POWER

AC-3 /400 V (kW)

RATED CURRENTMAIN

CONTACTS

Ie

AC-1 (A)

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC- 1R03 (24 VDC) R12 (110 VDC) R15 (220 VDC)

CWC07-00-22 S 3 7 18

2NO + 2NC

18 11646608 11646611 11646616 381,00

CWC09-00-22 S 4 9 20 20 11646609 11646613 11646617 423,00

CWC012-00-22 S 5,5 12 22 22 11646610 11646614 11646618 431,00

Note : For applications where there is a significant reduction on the rated voltage, sometimes due to long distances or network problems.

Page 50: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

96 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 97

Accessories for CWM 4-Pole Contactors

ACCESSORIES FOR 4-POLE COMPACT CONTACTORS CWC0

SPARE CONTACT SET

TYPE CONTACTORS STOCK CODEPRICE EACH

(ZAR)

JCC07-4P CWC07-00-40 10650966 146,00

JCC07-2P/2R CWC07-00-22 10662929 146,00

JCC09-4P CWC09-00-40 10212411 162,00

JCC09-2P/2R CWC09-00-22 10212412 162,00

JCC012-4P CWC012-00-40 10212413 165,00

JCC012-2P/2R CWC012-00-22 10212414 165,00

JCC016-4P CWC016-00-40 10212415 176,00

JCC016-2P/2R CWC016-00-22 10212416 176,00

TYPE CONTACTORS STOCK CODEPRICE EACH

(ZAR)

JCCB07-4P CWC07-00-40 10212403 146,00

JCCB07-2P/2R CWC07-00-22 10212404 146,00

JCCB09-4P CWC09-00-40 10212405 162,00

JCCB09-2P/2R CWC09-00-22 10212406 162,00

JCCB012-4P CWC012-00-40 10212407 165,00

JCCB012-2P/2R CWC012-00-22 10212408 165,00

JCCB016-4P CWC016-00-40 10212409 176,00

JCCB016-2P/2R CWC016-00-22 10212410 176,00

Note : Other accessories for 4-Pole contactors, see 3-Pole contactor’s accessories.

CONTACTORS - DC COIL

CONTACTORS - AC COIL

Contactors

The CWM general-purpose contactor line has been designed taking into consideration industrial duty and reliability.

Rated for inductive loads up to 800 A or 440 kW@ 380/400 V, WEG can offer the most suitable contactor for your application.

CWM contactors allow total panel space optimization, with only a few compact frame sizes from 4 to 440 kW@ 400/415 V. Reducing inventory is simple with CWM common accessories. For example, side-mounted auxiliary contact blocks are the same from 9 to 300 A (AC-3) @ 440 V.

Designed for extended mechanical and electrical life, dependable switching in even the most heavy-duty applications can be achieved. No matter how demanding the application, all WEG contactors are tested and approved to be used under Type 1 and Type 2 short circuit coordination.Ensuring global acceptance, all components conform to UL508 (USA and Canada), IEC60947 and CE.

All WEG contactors are manufactured to assure the highest quality manufacturing processes and component materials.

This way, WEG offers reliable solutions for low-voltage applications in electric panel assemblers, OEMs, distributors and end users.

CERTIFICATIONS

Page 51: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

98 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 99

3-Pole CWM Contactors

CONTACTORS CWM - 9 TO 105 A - SCREW TYPE

TYPERATED POWER

AC-3 / 400 V (kW)

RATED CURRENT

AUX. CONTACT

STOCK CODEPRICE EACH

(ZAR)D02 (24 V) D13 (110 V) D24 (230 V) D34 (400 V) D42 (500V)I

e

AC-3

Ith

AC-1

CWM9-10-30

4 9 25

1NO 10045468 10045459 10046166 10046175 10075308 319,00

CWM9-01-30 1NC 10045483 10185991 10186234 10071244 10075309 319,00

CWM9-11-30 1NO + 1NC 10648078 10045509 10410284 10652786 10075310 357,00

CWM9-22-30 2NO + 2NC 10211705 10409964 10072177 10867018 10075311 434,00

CWM12-10-30

5.5 12 25

1NO 10409944 10045467 10046176 10046189 10075312 336,00

CWM12-01-30 1NC 10046186 10045473 10645190 10071245 10075313 336,00

CWM12-11-30 1NO + 1NC 10046218 10045520 10647919 10647951 10075314 374,00

CWM12-22-30 2NO + 2NC 11783516 10072699 10211632 10867019 10075315 451,00

CWM18-10-30

9.2 18 32

1NO 10409943 10045478 10046177 10046211 10075316 361,00

CWM18-01-30 1NC 10045482 10045477 10186235 10071246 10075317 361,00

CWM18-11-30 1NO + 1NC 10073302 10045532 10646073 10648667 10075318 400,00

CWM18-22-30 2NO + 2NC 10648695 10045612 10072178 10867021 10075319 476,00

CWM25-00-30

11 25 45

- 10045488 10045491 10046195 10046233 10075320 517,00

CWM25-10-30 1NO 10045494 10045627 10046178 10186339 10075321 555,00

CWM25-01-30 1NC 10046151 10646660 10646728 10071247 10075322 555,00

CWM25-11-30 1NO + 1NC 10071289 10045444 10647030 10647160 10075323 593,00

CWM25-22-30 2NO + 2NC 10186429 10045614 10647212 10867022 10075324 669,00

CWM32-00-30

15 32 60

- 10045502 10045503 10071613 10647991 10075325 772,00

CWM32-10-30 1NO 10045629 10186030 10046281 10211634 10075326 810,00

CWM32-01-30 1NC 10072056 10045497 10648041 10073651 10075327 810,00

CWM32-11-30 1NO + 1NC 10071647 10045540 10072179 10867024 10075328 848,00

CWM32-22-30 2NO + 2NC 10848056 10186022 10072180 10867025 10075329 925,00

CWM40-00-30

18.5 40 60

- 10045549 10045546 10046196 10648637 10075330 862,00

CWM40-11-30 1NO + 1NC 10045507 10185998 10046204 10186379 10075331 938,00

CWM40-22-30 2NO + 2NC 10076717 10045616 10648838 10867026 10075332 1015,00

CWM50-00-30

22 50 90

- 10045554 10045552 10046197 10211184 10075333 1458,00

CWM50-11-30 1NO + 1NC 10045517 10045514 10186240 10646108 10075334 1534,00

CWM50-22-30 2NO + 2NC 10076947 10071434 10072181 10867027 10075335 1611,00

CWM65-00-30

30 65 110

- 10045560 10045561 10046198 10651509 10075336 1678,00

CWM65-11-30 1NO + 1NC 10045526 10045523 10186241 10186381 10075337 1755,00

CWM65-22-30 2NO + 2NC 10878782 10045563 10651874 10867048 10075338 1831,00

CWM80-00-30

37 80 110

- 10045568 10186231 10046199 10071248 10075339 1769,00

CWM80-11-30 1NO + 1NC 10071427 10045531 10046205 10653006 10075340 1845,00

CWM80-22-30 2NO + 2NC 10878783 10649472 10653089 10867049 10075431 1922,00

CWM95-00-30

45 95 140

- 10071290 10186014 10186236 10071249 10075342 2402,00

CWM95-11-30 1NO + 1NC 10071429 10045537 10186318 10186431 10075343 2479,00

CWM95-22-30 2NO + 2NC 11730134 10649561 10046296 10867050 10075344 2555,00

CWM105-00-30

55 105 140

- 10071287 10071594 10211339 10071250 10075345 2633,00

CWM105-11-30 1NO + 1NC 10071288 10045570 10186342 10186432 10075346 2709,00

CWM105-22-30 2NO + 2NC 11287725 10647219 10647220 10867051 10075347 2786,00

CONTACTORS CWM - 112 TO 250 A - SCREW TYPE

TYPERATED POWER

AC-3 / 400 V (kW)

RATED CURRENT

AUX. CONTACT

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC-1 D02 (24 V) D13 (110 V) D24 (230 V) D34 (400 V) D42 (500 V)

CWM112-22-30 55 112 180 2NO + 2NC 10789753 10046220 10211191 10071251 10075365 4090,00

CWM180-22-30 90 180 225 2NO + 2NC 10076716 10045397 10046234 10071252 1075366 6488,00

CWM250-22-30 132 250 350 2NO + 2NC 11498681 10046280 10046235 10071253 10075367 10127,00

Note : Auxiliary block front mounting available at a maximum of 2 contacts.

- Smart code of the rated voltage.

3-Pole CWM Contactors

Note : 1) Contactor with coil + electronic Module to alternating current (50/60 Hz) and direct current.

2) Upon Request.

Auxiliary block front mounting available at a maximum of 2 contacts.

- Smart code of the rated voltage.

CONTACTORS CWM (WITH ELECTRONIC MODULE) - 112 UP TO 800 A 1) - SCREW TYPE

CONTACTORS CWM - 9 UP TO 105 A - DC COIL - SCREW TYPE

TYPERATED POWER

AC-3 / 400 V (kW)

RATED CURRENT

AUX. CONTACT

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC-3C03 (24 VDC) C12 (110 VDC) C15 (220 VDC)

CWM9-10-304 9 25

1NO 10535681 10535702 10045445 444,00

CWM9-01-30 1NC 10535682 10535703 10618332 444,00

CWM12-10-305.5 12 25

1NO 10535683 10535704 10211249 484,00

CWM12-01-30 1NC 10535684 10535705 10071380 484,00

CWM18-10-307.5 18 32

1NO 10535685 10535706 10045449 933,00

CWM18-01-30 1NC 10535686 10535707 10071386 933,00

CWM25-00-30

11 25 45

- 10535687 10535708 10075720 1000,00

CWM25-10-30 1NO 10535688 10535709 10071389 1038,00

CWM25-01-30 1NC 10535689 10535710 10071394 1038,00

TYPERATED POWER

AC-3 / 400 V (kW)

RATED CURRENT

AUX. CONTACT

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC-3C03 (24 VDC) C12 (110 VDC) C15 (220 VDC)

CWM32-00-30

15 32 60

- 10748948 10535711 10723363 1454,00

CWM32-10-30 1NO 10535691 10535712 10070729 1492,00

CWM32-01-30 1NC 10535692 10535713 10070730 1492,00

CWM40-00-3018.5 40 60

- 10535693 10535714 10648504 1748,00

CWM40-11-30 1NO + 1NC 10535694 10535715 10647675 1825,00

CWM50-00-3022 50 90

- 10649039 10535716 10047383 4679,00

CWM50-11-30 1NO + 1NC 10261727 10535717 10647840 4755,00

CWM65-00-3030 65 110

- 10535696 10535718 10651470 5112,00

CWM65-11-30 1NO + 1NC 10261728 10535719 10649108 5188,00

CWM80-00-3037 80 110

- 10652134 10535720 10652133 5243,00

CWM80-11-30 1NO + 1NC 10535698 10535721 10649403 5320,00

CWM95-00-3045 95 140

10653031 10535722 10653026 5374,00

CWM95-11-30 1NO + 1NC 10535699 10535723 10648557 5451,00

CWM105-00-3055 105 140

- 10647068 10535724 Upon request 2) 5442,00

CWM105-11-30 1NO + 1NC 10535701 10261730 10656159 5519,00

TYPERATED POWER

AC-3 /400 V (kW)

RATED CURRENT

AUX. CONTACT

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC-1

E02

(24-28 V)

E10

(110-130 V)

E13

(208-250 V)

E16

(360-415 V)

CWM112-22-30 55 112 180 2NO + 2NC 10535725 10535740 10535745 10535750 5297,00

CWM150-22-30 75 150 225 2NO + 2NC 10535726 10535741 10535746 10535751 5461,00

CWM180-22-30 90 180 350 2NO + 2NC 10535727 10535742 10535747 10535752 8064,00

CWM250-22-30 132 250 350 2NO + 2NC 10535728 10535743 10535748 10535753 11530,00

CWM300-22-30 160 300 410 2NO + 2NC 10535729 10535744 10535749 10535754 13004,00

TYPERATED POWER

AC-3 / 400 V (kW)

RATED POWER

AUX. CONTACT

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC-1

E36 (100-240 V AC/CA

/100-220 V DC/CC)D81 (380-450 V AC/CA)

CWM400-22-30 200 400 450 2NO + 2NC 11747363 11747367 18841,00

TYPERATED POWER

AC-3 / 400 V (kW)

RATED CURRENT

AUX. CONTACT

STOCK CODE

PRICE EACH

(ZAR)Ie

AC-3

Ith

AC-1

E35 (100-127

VAC 100-110

VDC)

E39 (200-240

VAC 200-220

VDC)

D81 (380-450

VAC)

D82 (440-575

VAC)

CWM630-22-30 250 630 330 2NO + 2NC 11747430 11747434 11860886 12122025 28305,00

CWM800-22-30 300 800 440 2NO + 2NC 11747431 11747436 11860928 12317737 41428,00

Page 52: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

100 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 101

4-Pole Contactors

4-POLE CONTACTORS CWM - SCREW TYPE

4-POLE CONTACTORS - “CWM” 9 TO 18A - AC COIL

4-POLE CONTACTORS - “CWM” 9 TO 18A - DC COIL

4-POLE CONTACTORS CWM (WITH ELECTRONIC MODULE) - 400 UP TO 800 A

TYPERATED POWER

AC-3 /400 V (kW)

RATED CURRENTMAIN

CONTACTS

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC- 1D24 (230 V) D34 (400 V)

CWM9-00-40 3,7 9 25

4NO

10073258 10073259 334,00

CWM12-00-40 5,5 12 25 10072159 10867261 350,00

CWM18-00-40 7,5 18 32 10046300 10867262 384,00

CWM9-00-22 3,7 9 25

2NO + 2NC

10653526 10867263 334,00

CWM12-00-22 5,5 12 25 10648247 10867264 350,00

CWM18-00-22 7,5 18 32 10075457 10867265 384,00

TYPE RATED POWER

AC-3 /400 V (kW)

RATED CURRENTMAIN

CONTACTS

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC- 1C03 (24 VDC) C15 (220 VDC)

CWM9-00-40 3,7 9 25

4NO

10046963 10075282 469,00

CWM12-00-40 5,5 12 25 10071459 10072086 509,00

CWM18-00-40 7,5 18 32 10045595 10186215 976,00

CWM9-00-22 3,7 9 25

2NO + 2NC

10073333 10075283 469,00

CWM12-00-22 5,5 12 25 10045600 10648221 509,00

CWM18-00-22 7,5 18 32 10071504 11030460 976,00

TYPERATED POWER

AC-3 /400 V (kW)

RATED CURRENT

AUX. CONTACTS

STOCK CODEPRICE EACH

(ZAR)Ie

AC-3

Ith

AC- 1

E36

(100-240 VAC / 100-220 VDC)

D81

(380-450 VAC

CWM400-22-40 20 400 2NO + 2NC 11931204 11931205 25059,00

TYPERATED POWER

AC-3 /400 V (kW)

RATED CURRENT

AUX. CONTACTS

E35

(100-127 VAC /

100-110 VDC)

E35

(100-127 VAC /

100-110 VDC)

D81

(380-450 VAC

PRICE EACH

(ZAR)Ie

AC-3

Ith

AC- 1

CWM500-22-40 265 500 2NO + 2NC 11931206 11931207 Upon request 1) 32564,00

CWM630-22-40 330 660 660 2NO + 2NC 11931258 11931259 Upon request 1) 37646,00

CWM800-22-40 800 800 900 2NO + 2NC 11931260 11931261 Upon request 1) 53860,00

Note : 1) Upon Request.

For applications where there is a significant reduction on the rated voltage, sometimes due to long distances or network problems.

- Smart code of the rated voltage.

MAIN CONTACTS

Reference code

CW

M9

CW

M12

CW

M18

CW

M25

CW

M32

CW

M40

CW

M50

CW

M65

CW

M80

CW

M95

CW

M105

CW

M112

CW

M150

CW

M180

CW

M250

CW

M300

Rated

operational

current Ie

AC-3 (Ue ≤ 440 V) (A) 9 12 18 25 32 40 50 65 80 95 105 112 150 180 250 300

AC-4 (Ue ≤ 440 V) (A) 5 7 8 12 16 18.5 23 30 37 44 50 63 69 73 110 145

AC-1 ( ≤ 55 °C, Ue ≤ 690 V) (A) 25 25 32 45 60 60 90 110 110 140 140 180 225 225 350 410

Rated

operational

voltage Ue

IEC/EN 60947-4-1, VDE 0660 (V) 690 1000

UL, CSA (V) 600

Rated thermal current Ith ( ≤ 55 °C) (A) 25 25 32 45 60 60 90 110 110 140 140 180 225 225 350 410

Making capacity - IEC/EN 60947 (A) 300 300 300 450 550 550 1000 1000 1000 1280 1280 1430 1820 2100 2600 3000

Breaking

capacity

IEC/EN 60947

(Ue≤400 V) (A) 250 250 250 350 450 450 920 920 920 1050 1050 1290 1350 1400 2000 -

(Ue=500 V) (A) 250 250 250 320 450 450 920 920 920 1050 1050 1290 1350 1400 2000 -

(Ue=690 V) (A) 130 130 130 170 205 205 780 780 780 950 950 - - - - -

Short-time

current

No current

flowing during

recovery time

10 min. and

≤ 40 °C)

1 sec (A) 455 455 570 630 1010 1265 1580 2530 2530 3300 3300 3165 3763 4649 4427 -

5 sec (A) 205 205 254 280 450 450 710 1130 1130 1485 1485 1820 2164 2673 2546 -

10 sec (A) 144 144 180 200 320 400 500 800 800 1050 1050 1430 1700 2100 2000 -

30 sec (A) 85 85 104 115 185 230 290 460 460 600 600 826 980 1212 1155

1 min (A) 60 60 74 80 130 165 205 325 325 430 430 584 694 857 816 -

3 min (A) 35 35 46 50 90 100 120 185 185 250 250 337 401 495 471 -

Protection

against short-

circuits with

fuses(gL/gG)

@600 V - UL/CSA (kA) 5 10 18

Coordination type 1 (A) 50 50 63 63 100 125 200 200 200 250 250 - 355 355 500 630

Coordination type 2 (A) 25 35 35 50 63 80 100 125 125 160 200 224 250 250 400 500

Impedance per pole (mΩ) 2.4 2.4 2.4 1.7 1.3 1.0 0.9 0.9 0.9 0.8 0.8 0.5 0.5 0.45 0.3 0.3

Power dissipation

per pole

AC-1 (W) 1.5 1.5 2.5 3.3 4.6 3.4 6.7 10.4 10.4 14.9 14.9 16 25 21.6 35 45.7

AC-3 (W) 0.2 0.3 0.8 1.0 1.3 1.5 2.1 3.6 5.5 6.9 8.4 6.2 11.1 13.8 17.9 25.7

Utilization category AC-3

Rated

operational

current Ie

( ≤ 55 °C)

Ue ≤ 440 V (A) 9 12 18 25 32 40 50 65 80 95 105 112 150 180 250 300

Ue ≤ 500 V (A) 7.5 10.5 14 19 24 32 38 55 63 79 85 95 130 155 220 265

Ue ≤ 690 V (A) 7 9 13 15 22 25 34 44 48 60 67 82 110 135 185 220

Ue ≤ 1000 V (A) Not available 19 25 30 37 40 42 48 68 103 126

Rated

operational

power

220 / 230 V (kW) 2.2 3 4.5 5.5 9.2 11 15 18.5 22 22 30 30 45 55 75 90

(hp) 3 4 6 7.5 12.5 15 20 25 30 30 40 40 60 75 100 125

380 / V (kW) 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 55 75 90 132 150

(hp) 5 7.5 10 15 20 25 30 40 50 60 75 75 100 125 175 200

400 / 415 V (kW) 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 55 75 110 132 150

(hp) 5 7.5 10 15 20 25 30 40 50 60 75 75 100 150 175 200

440 V (kW) 4.5 5.5 9.2 11 15 22 30 37 45 55 55 55 90 110 150 185

(hp) 6 7.5 12.5 15 20 30 40 50 60 75 75 75 125 150 200 250

500 V (kW) 4.5 5.5 9.2 11 15 22 30 37 45 55 55 55 90 110 150 185

(hp) 6 7.5 12.5 15 20 30 40 50 60 75 75 75 125 150 200 250

660 / 690 V (kW) 5.5 7.5 11 11 18.5 22 30 37 45 55 55 75 110 110 150 185

(hp) 7.5 10 15 15 25 30 40 50 60 75 75 100 150 150 200 250

Percentage of

the maximum

operational

current at

600 ops./h (%) 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100

1200 ops./h (%) 100 100 100 100 100 100 100 100 100 75 75 75 75 75 75 75

3000 ops./h (%) 35 35 35 35 35 35 35 35 35 25 25 25 25 25 25 25

Utilization category AC-4

Rated operational current Ie AC-4 (Ue ≤ 690 V) (A) 5 7 8 12 16 18.5 23 30 37 44 50 50 55 58 88 116

Rated

operational

power

220 / 230 V (kW) 1.1 1.5 1.5 3 3.7 4.5 55 7.5 9.2 11 11 18.5 18.5 22 37 45

(hp) 1.5 2 2 4 5 6 7.5 10 12.5 15 15 25 25 30 50 60

380 / 400 V (kW) 2.2 3 3.7 5.5 7.5 9.2 11 15 18.5 22 22 30 30 37 55 75

(hp) 3 4 5 7.5 10 12.5 15 20 25 30 30 40 40 50 75 100

415 V (kW) 2.2 3.7 4.5 5.5 9.2 11 11 15 22 22 30 37 37 45 55 75

(hp) 3 5 6 7.5 12.5 15 15 20 30 30 40 50 50 60 75 100

440 V (kW) 2.2 3.7 4.5 5.5 9.2 11 11 15 22 22 30 37 37 45 55 75

(hp) 3 5 6 7.5 125 15 15 20 30 30 40 50 50 60 75 100

500 V (kW) 3 3.7 5.5 7.5 9.2 11 15 18.5 22 22 30 37 45 45 75 90

(cv) 4 5 7.5 10 12.5 15 20 25 30 30 40 50 60 60 100 125

660 / 690 V (kW) 3 4.5 5.5 7.5 11 11 15 18.5 22 30 30 45 45 55 90 90

(cv) 4 6 7.5 10 15 15 20 25 30 40 40 60 60 75 125 125

Contactors - Technical Data

Page 53: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

102 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 103

MAIN CONTACTS

UL POWER RATINGS

Reference code

CW

M9

CW

M12

CW

M18

CW

M25

CW

M32

CW

M40

CW

M50

CW

M65

CW

M80

CW

M95

CW

M105

CW

M112

CW

M150

CW

M180

CW

M300

Utilization category AC-1

3P (NO) or 4P (4NO) 3P (NO) 3P (NO)

Rated thermal current Ith ( ≤ 55 °C) (A) 25 25 32 45 60 60 90 110 110 140 140 180 225 225 410

Max. operational current at ambient

temperature of (up to 690 V)

≤ 55 °C (A) 25 25 32 45 60 60 90 110 110 140 140 160 190 200 350

≤ 70 °C (A) 20 20 25 32 48 48 72 88 88 110 110 120 145 145 250

≤ 75 °C (A) 17 17 22 26 42 42 63 77 77 95 95 101 124 120 206

Max. operational power

≤ 55 °C

(Three-phase resistors)

220 / 230 V (kW) 9.5 9.5 12 17 22.5 22.5 34 42 42 53 53 68 85 85 156

380 / 400 V (kW) 16.5 16.5 21 29.5 39.5 39.5 59 72.5 72.5 92 92 118 145 145 270

415 / 440 V (kW) 19 19 24 34 45.5 45.5 68.5 84 84 106.5 106.5 130 160 160 295

500 V (kW) 21.5 21.5 27.5 39 52 52 77 95 95 121 121 155 190 190 355

575 / 600 V (kW) 24.1 24.1 30.9 43.4 57.9 57.9 86.8 106.1 106.1 135.1 135.1 180 225 225 400

660 / 690 V (kW) 28.5 28.5 38 51 68.5 68.5 100 125 125 160 160 205 255 255 470

Cable size (mm²) 4 4 6 10 16 16 35 35 35 50 50 120 120 1202 x

150

Current values for connection of

2 poles in parallel Ie x 1.7

3 poles in parallel Ie x 2.4

4 poles in parallel Ie x 3.2

Percentage of the maximum operational

current at

600 ops./h (%) 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100

1200 ops./h (%) 100 100 100 100 100 100 100 100 100 80 80 80 80 80 80

3000 ops./h (%) 50 50 50 50 50 50 50 50 50 40 40 40 40 40 40

2P (NO/NC)

4P (2NO+2NC)2P (NO/NC)

Max. operational power

≤ 55 °C

(Resistive loads)

220 / 230 V (kW) 5.5 5.5 7.04 9.9 13.2 14.9 22.2 27.5 27.5 34.1 34.1 - - - -

380 / 400 V (kW) 9.5 9.5 12.1 17.1 22.8 25.8 38.6 47.5 47.5 58.9 58.9 - - - -

415 / 440 V (kW) 10.3 10.3 13.2 18.6 24.9 28.2 42.3 51.8 51.8 64.3 64.3 - - - -

500 V (kW) 12.5 12.5 16 22.5 30 34 50.6 62.5 62.5 77.5 77.5 - - - -

660 / 690 V (kW) 16.5 16.5 21.1 29.7 39.6 44.8 66 82.5 82.5 102.3 102.3 - - - -

Contactors - Technical Data

Reference code

CW

M9

CW

M12

CW

M18

CW

M25

CW

M32

CW

M40

CW

M50

CW

M65

CW

M80

CW

M95

CW

M105

CW

M112

CW

M150

CW

M180

CW

M250

CW

M300

General purpose current (600 V) (A) 25 25 32 32 60 60 90 110 110 140 140 170 200 200 300 400

1-phase110 / 120 V (hp) 0,75 0,75 1 2 3 3 5 5 7,5 7,5 10 - - - - -

220 / 240 V (hp) 1,5 2 3 5 5 5 7,5 10 15 15 20 - - - - -

3-phase

200 V (hp) 3 3 5 7,5 10 10 15 20 20 25 30 40 50 60 75 100

220 / 240 V (hp) 3 3 5 7,5 10 15 15 20 25 30 40 50 60 75 100 125

440 / 480 V (hp) 5 7,5 10 15 20 30 40 50 50 60 75 100 125 150 200 250

550 / 600 V (hp) 7,5 10 15 15 25 25 40 50 60 75 75 100 150 200 250 350

Reference code CWM400 CWM500 CWM630 CWM800

Standards IEC/EN 60 947. DIN VDE 0660. UL. CSA

Rated insulation voltage Ui

IEC/EN 60 947. DIN VDE 0660

UL. CSA

1000 V

600 V

Rated impuse withstand voltage Uimp

6 kV

Rated operational frequency 25 - 400 Hz

Degree of protection

Main circuits

Control circuits and auxiliary contacts

IP00

IP20

Ambient temperature

Operating temperature

Storage temperature

-25 oC to + 55 oC

-55 oC to + 80 oC

Altitude

Normal values

90% Ie / 80% U

e

80% Ie / 75% U

e

Up to 3000 m

3000 to 4000 m

4000 to 5000 m

Overvoltage category / Pollution degree III / 3

Climatic proofing Acc. to IEC 60680-2

Pole numbers of main circuits 3

Rated operation voltage Ue

690 V

Conv. thermal current Ith

at < 55 oC rated operational current Ie/AC-1 (A)450 580 660 900

Rated operational current Ie AC-4 (U

e ≤ 440 V) (A) 300 350 400 630

AC-3 utilization category

Rated operational power

220-230 V (kW)

400-415 V (kW)

440 V (kW)

500 V (kW)

690 V (kW)

125

220

220

225

250

150

265

265

265

300

190

330

330

330

330

220

440

440

500

500

Short circuit rating max. fuse gL-gG 1) (A) 630 800 800 1000

Max. electrical operational per hour

AC-1 Ops/h

AC-3 Ops/h

AC-4 Ops/h

No load Ops/h

300

1200

150

1200

300

1200

150

1200

300

1200

150

1200

300

1200

150

1200

Mechanical lifespan Ops x 106 5

Electrical lifespan (AC - 3) Ops x 106 0.5 0.6

CONTROL CIRCUIT

UL POWER RATINGS

GENERAL DATA AND POWER CIRCUIT FOR CWM400...CWM800

Reference code (3 pole and 4 pole contactors) CWM400 CWM500 CWM630 CWM800

Coil operation limit 0.85...1.1 x Us

Pick-up (xUs) 0.78 0.75

Drop-out (xUs) 0.30...0.60 0.30...0.60

Coil consumption

Closing (VA) 571 1000

Closed (VA) 14 29

Dissipation (W) 5 7.8

Number of terminals 2

Contactors - Technical Data

Reference code CWM400 CWM500 CWM630 CWM800

General purpose current (600 V) (A) 450 580 660 900

3-phase

200 V (HP) 125 150 200 200

220 / 240 V (HP) 150 200 250 300

440 / 480 V (HP) 300 400 500 600

550 / 600 V (HP) 300 400 500 600

Note: 1) Type 2 coordination.

Page 54: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

104 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 105

Accessories for CWM Contactors

ACCESSORIES FOR CONTACTORS CWM

AUXILIARY CONTACT BLOCKS - FRONTAL MOUNTING

AUXILIARY CONTACT BLOCKS - SIDE MOUNTING

TYPE CONTACTORS AUX. CONTACTS STOCK CODEPRICE EACH

(ZAR)

BCXMF 10

CWM9...105

1NO 10356473 37,00

BCXMF 01 1NC 10356494 37,00

BCXMFA 10 1NO E.M. 1) 10186059 57,00

BCXMFR 01 1NC L.B. 2) 10045713 57,00

TYPE CONTACTORS AUX. CONTACTS STOCK CODEPRICE EACH

(ZAR)

BCXML 20

CWM9...105

CWM112...300

2NO 10045714 100,00

BCXML 11 1NO + 1NC 10459053 100,00

BCXMRL 20 2NO 10186060 113,00

BCXMRL 11 1NO + 1NC 10045715 113,00

BCXML11 CWM800 CWM400 / 500 / 630 / 800 1NO + 1NC 10186852 373,00

BCXMRL11 CWM800 CWM400 / 500 / 630 / 800 1NO + 1NC 10766850 373,00

Note : 1) E.M. = early-make contact.

2) L.B. = late-brake contact.

Contactors and Mechanical Interlock Blocks may be bought separately.

Accessories for CWM Contactors

ACCESSORIES FOR CONTACTORS CWM

BUS BAR STAR-DELTA STARTER / EC-SD - EASY CONNECTION

BUS BAR REVERSING STARTER / EC-R - EASY CONNECTION

TYPE DESCRIPTION

RATED POWER COMPONENTS

STOCK CODEPRICE EACH

(ZAR)220-240 V (kW) 380-415 V (kW) K1 = K2 K3

EC-SD-15 Star-delta starter EC-SD - 155.5 11 CWM18 CWM9 10045347 260,00

7.5 15 CWM18 CWM12 10045347 260,00

EC-SD-22 Star-delta starter EC-SD - 227.5 18.5 CWM25 CWM18 10045323 340,00

11 22 CWM25 CWM18 10045323 340,00

EC-SD-25 Star-delta starter EC-SD - 25 15 22 CWM32 CWM18 10074592 354,00

EC-SD-30 Star-delta starter EC-SD - 30 15 30 CWM40 CWM25 10045324 425,00

EC-SD-37 Star-delta starter EC-SD - 37 18.5 37 CWM50 CWM25 10045325 473,00

EC-SD-55 Star-delta starter EC-SD - 5522 45 CWM50 CWM32 10185928 476,00

30 55 CWM65 CWM40 10185928 476,00

EC-SD-75 Star-delta starter EC-SD - 75 37 75 CWM80 CWM50 11134959 523,00

EC-SD-90 Star-delta starter EC-SD - 9037 75 CWM95 CWM50 10045326 523,00

45 90 CWM105 CWM65 10045326 523,00

TYPE DESCRIPTION

RATED POWER COMPONENTS

STOCK CODEPRICE EACH

(ZAR)220-240 V (kW) 380-415 V (kW) K1 = K2 BLIM

EC-R-7.5 Reversing starter EC-R - 7.5

2.2 3.7 CWM9

BLIM 9-105

10071342 199,00

3.7 5.5 CWM12 10071342 199,00

4.5 7.5 CWM18 10071342 199,00

EC-R-11 Reversing starter EC-R - 11 5.5 11 CWM25 BLIM 9-105 10185926 288,00

EC-R-18.5 Reversing starter EC-R - 18.59.2 15 CWM32

BLIM 9-10510071340 342,00

11 18.5 CWM40 10071340 342,00

EC-R-37 Reversing starter EC-R - 37

15 22 CWM50

BLIM 9-105

10185927 430,00

18.5 30 CWM65 10185927 430,00

22 45 CWM80 10185927 430,00

Note : Contactors and Mechanical Interlock Blocks may be bought separately.

Page 55: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

106 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 107

Accessories for CWM Contactors

ACCESSORIES FOR CONTACTORS CWM

MECHANICAL INTERLOCK BLOCK

SPARE CONTACT SET

TYPE CONTACTORS STOCK CODEPRICE EACH

(ZAR)

BLIM9-105 CWM9...CWM105 10410084 123,00

BLIM.02 CWM9-105 1) CWM9...CWM105 10046839 160,00

BLIM112-300 CWM112...CWM300 10045676 383,00

BLIM CWM400 CWM400 3P/4P 10186853 372,00

BLIM CWM800 CWM500/630/800 3P 10047279 11167,00

BLIM CWM800-4P CWM500/630/800 4P 11308440 15018,00

TYPE CONTACTORS STOCK CODEPRICE EACH

(ZAR)

JC CWM9-3P CWM 9 10410069 89,00

JC CWM12-3P CWM 12 10410070 95,00

JC CWM18-3P CWM 18 10410071 101,00

JC CWM25-3P CWM 25 10410072 225,00

JC CWM32-3P CWM 32 10410073 274,00

JC CWM40-3P CWM 40 10410074 308,00

JC CWM50-3P CWM 50 10410075 610,00

JC CWM65-3P CWM 65 10410076 654,00

JC CWM80-3P CWM 80 10410077 687,00

JC CWM95-3P CWM 95 10410078 964,00

JC CWM105-3P CWM 105 10410079 1121,00

JC CWM112-3P CWM 112 10410050 2457,00

JC CWM150E-3P CWM 150 10186245 2692,00

JC CWM180-3P CWM 180 10410051 3366,00

JC CWM250-3P CWM 250 10186043 4948,00

JC CWM300-3P CWM 300 10187066 5581,00

JC CWM400-3P CWM400 10213097 3127,00

JC CWM500-3P CWM500 10213097 3127,00

JC CWM630-3P CWM630 10213098 3909,00

JC CWM800-3P CWM800 10213099 4653,00

Note : 1) Allows mechanical and electrical interlock through the 2 built-in NC contacts.

Quantity per packing: 3 units of fixed contacts.

Accessories for CWM Contactors

ACCESSORIES FOR CONTACTORS CWM

SURGE SUPPRESSOR BLOCK

TYPE CONTACTORS VOLTAGE STOCK CODEPRICE EACH

(ZAR)

BAMRC4 D53

CWM9...40

24-48 V ac/ca 10045301 123,00

BAMRC5 D55 50-127 V ac/ca 10045302 123,00

BAMRC6 D63 130-250 V ac/ca 10409766 123,00

BAMRC7 D53

CWM50...105

24-48 V ac/ca 10045303 123,00

BAMRC8 D55 50-127 V ac/ca 10045304 123,00

BAMRC9 D63 130-250 V ac/ca 10409767 123,00

BAMDI10 C33 CWM9...25

CWM112, CWM180

CWM250

12-600 V dc/cc 10045305 123,00

BAMRC13 D53 24-48 V ac/ca 10046242 123,00

BAMRC14 D56 50-250 V ac/ca 10046243 123,00

BAMV1 D68CWM9...105

270-380 V ac/ca 10664749 123,00

BAMV2 D73 400-510 V ac/ca 10046382 123,00

BAMV3 D68 CWM112, CWM180

CWM250

270-380 V ac/ca 10046383 123,00

BAMV4 D73 400-510 V ac/ca 10046384 123,00

Note : 1) Allows mechanical and electrical interlock through the 2 built-in NC contacts.

Page 56: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

108 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 109

Accessories for CWM Contactors

ACCESSORIES FOR CONTACTORS CWM

ADAPTERS FOR EYE BOLT TERMINALS

EXTINGUISH CHAMBERS

AC COILS

CWMC AC COILS

SIDE CONNECTION BUS BAR (STAR DELTA CONNECTION)

TYPE CONTACTORS STOCK CODEPRICE EACH

(ZAR)

ATO 50/65/80 CWM 50/65/80 10070852 141,00

ATO 95/105 CWM 95/105 10045716 653,00

TYPE OVERLOAD RELAY STOCK CODEPRICE EACH

(ZAR)

ATO 117D RW117-2D 10045717 318,00

TYPE CONTACTORS STOCK CODEPRICE EACH

(ZAR)

CE112 CWM112 10045675 598,00

CE150E CWM150 10071711 624,00

CE180 CWM180 10071515 929,00

CE250 CWM250 10071516 1157,00

CE300E CWM300 10657219 1291,00

TYPE CONTACTORS

STOCK CODEPRICE EACH

(ZAR)D02 (24 V) D07 (48 V) D13 (110 V) D24 (230 V) D34 (400 V)

BCA4-25 CWM 9...25 10045705 10045706 10045707 10046301 10211186 93,00

BCA4-40 CWM32...40 10047474 10047477 10047475 10656650 10187589 136,00

BCA-105 CWM 50...105 10045696 10046298 10045692 10046324 10656781 182,00

BCA-112 CWM 112 10656888 10071616 10656867 10071750 10071259 282,00

BCA-180 CWM 180 10046202 10071617 10656895 10071751 10071735 455,00

BCA-250 CWM 250 10072870 11782491 10657695 10071752 10071734 549,00

TYPE CONTACTORS RATED FREQ. 50(Hz) X18 (110 V) X37 (230 V) X47 (400 V)PRICE EACH

(ZAR)

BCA4-25 CWMC25 50 11703672 11703596 11703597 117,00

BCA4-40 CWMC32 50 11703701 11703595 11703702 170,00

BCA-105 CWMC50/65 50 11703699 11703594 11703698 227,00

TYPE CONTACTORS

STOCK CODEPRICE EACH

(ZAR)E36 100-240 VAC / 100-220 VDC E19 380-450 VAC

BCE-400 CWM400 11746768 11746772 4188,00

TYPE CONTACTORSE35 100-127 VAC /

100-110 VDC

E39 200-240 VAC /

200-220 VACD81 380-450 VAC

PRICE EACH

(ZAR)

BCE-800 CWM 500 / 630 / 800 11746776 11746777 11746779 5119,00

TYPE CONTACTORS STOCK CODEPRICE EACH

(ZAR)

BCP-CWM50-105 CWM 50...105 10070853 102,00

Note : 1) Upon Request.

Article numbers for other rated voltages and frequencies upon request.

- Smart code of the rated voltage.

Note : Article numbers for coils with 3 edges/terminals upon request.

Accessories for CWM Contactors

ACCESSORIES FOR CONTACTORS CWM

TERMINAL COVERS

ROUND CABLE TERMINAL

DC COILS

ELECTRONIC MODULE

CWM COILS (AC-DC)

TYPE CONTACTOR PACKAGING STOCK CODEPRICE EACH

(ZAR)

BMP CWM180 CWM180 2 terminal covers 11762174 604,00

BMP CWM300 CWM250 / 300 2 terminal covers 11762177 604,00

BMP CWM400 CWM400 2 terminal covers 10047280 336,00

BMP CWM800 CWM 500/ 630 / 800 2 terminal covers 10047281 670,00

TYPE CONTACTOR PACKAGING STOCK CODEPRICE EACH

(ZAR)

BMP1 CWM150 CWM112 / 150 1 terminal cover 11898596 302,00

BMP1 CWM180 CWM180 1 terminal cover 11898597 302,00

BMP1 CWM300 CWM250 / 300 1 terminal cover 11898638 306,00

TYPE CONTACTORS PACKAGING STOCK CODEPRICE EACH

(ZAR)

BMJ CWM400 CWM400 3 10186854 1002,00

BMJ CWM800 CWM500 / 630 / 800 3 10186855 2120,00

TYPE CONTACTOR

STOCK CODEPRICE EACH

(ZAR)C03 (24 VDC) C12 (110 VDC) C15 (220 VDC)

BCC-25 CWM 9...CWM 25 10045694 10186053 10071533 312,00

TYPE CONTACTOR

STOCK CODEPRICE EACH

(ZAR)C34 (24-28 VDC) C40 (110-130 VDC) C44 (208-240 V DC)

BECC4-40 CWM 32 / CWM 40 10213264 10685151 10685178 655,00

BECC-105 CWM 50...CWM 105 10685182 10685200 10685205 737,00

TYPE CONTACTOR

STOCK CODEPRICE EACH

(ZAR)E10 (110-130 V) E13 (208-250 V) E16 (360-415 V)

ME-300 CWM112 / 150 / 180 / 250 / 300 10046223 10046264 10072133 1458,00

TYPE CONTACTOR

STOCK CODEPRICE EACH

(ZAR)E10 (110-130 V) E15 (220-250 V) E16 (360-415 V)

BCE-150 CWM 112 / 150 10071579 10071580 10046378 301,00

BCE-215 CWM180 10071581 10071582 10076211 478,00

BCE-300 CWM 250 / 300 10071583 10071584 10076212 606,00

TYPE CONTACTOR

STOCK CODEPRICE EACH

(ZAR)100-240 VAC / 100-220 VDC 380-450 VAC

BCE-400 CWM400 11746768 11746772 4188,00

TYPE CONTACTOR100-127 V AC/CA /

100-110 V DC/CC

200-240 V AC/CA /

200-220 V DC/CC380-450 V AC/CA

PRICE EACH

(ZAR)

BCE-800 CWM630 / 800 11746776 11746777 11746779 5119,00

Note : Article numbers for other rated voltages and frequencies upon request.

- Smart code of the rated voltage.

Note : Each set comes with 2 terminal covers, one for incoming terminals and other for outcoming terminals.

Page 57: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

110 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 111

Accessories for CWM 4-Pole Contactors

Note : Other accessories for 4-Pole contactors, see 3-Pole contactor’s accessories.

ACCESSORIES FOR 4-POLE CONTACTORS CWM

SPARE CONTACT SET

TYPE CONTACTORS STOCK CODEPRICE EACH

(ZAR)

JC CWM12-2P/2R CWM 12-2P/2R 10186063 136,00

JC CWM18-2P/2R CWM 18-2P/2R 10682151 146,00

JC CWM12-4P CWM 12-4P 10662915 118,00

JC CWM18-4P CWM 18-4P 10662916 134,00

Contactors for Switching of Capacitors

SWITCHING OF POWER FACTOR CORRECTION CAPACITORS

WEG’s special CWMC contactors series for switching of

capacitors is designed according to IEC 60947-1 and UL,

and provides the best solution for the switching of power

factor correction capacitors.

NO MORE IN-RUSH

When switching on a capacitor bank, the capacitors are

uncharged and the system sees them as a short circuit for a

quick period of time.

The in-rush current is the result of this little short circuit and

usually lasts for some milliseconds. It may reach 100 times the

rated current which one of the main reasons for the short life of

a capacitor.

The CWMC contactor is assembled with damping resistors

which limit the high in-rush current when the capacitors are

switched on. They are assembled with an early-make contact

block which is switched on before the main contacts thus,

limiting the in-rush current.

However, the damping resistors don’t influence the final load,

since they are switched off after 5 milliseconds leaving only

the capacitors in parallel with their inductive load providing the

proper power factor correction. This process increases the

lifetime of the capacitors and also prevents net distortions.

Iu (A) with atandard contactors Iu (A) with WEG CWMC contactor

CERTIFICATIONS

RS

R

Page 58: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

112 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 113

Contactors for Switching of Capacitors

New Models

CWMC contactors are available in 5 different models in 4 different frames. All contactors are available with AC coils with a large

variety of voltage ranges for 50 or 60 Hz. For DC coils and further information, please contact a WEG representative.

CWMC CONTACTOR FOR SWITCHING OF CAPACITORS (AC-6b)

MODULAR DESIGN

For 35 mm DIN rail or screw fixing.DAMPING RESISTORS

Avoids high in-rush current.

EARLY MAKE CONTACT BLOCK

Connects damping resistors and switches

off after 5ms.

CONTACTOR DATA AND CERTIFICATIONS

Shows all necessary information of CWMC.

AUXILIARY CONTACT

CWMC allows use of standard

contact blocks, the same used in

CWM line, being either NO or NC.

AC coil CWMC9 CWMC18 CWMC25 CWMC32 CWMC50 CWMC65 CWMC80

Reactive power

AC-6b @ 55 °C

220-230 V

kvar

6 8 11 15 25 30 35

380-415 V 10 15 20 25 40 50 61

440 V 12 16 23 30 45 60 71

480 V 12.5 17 25 33 50 65 77

660-690 V 17.5 25 34 45 65 87 106

AC-6b current (Ie) (55 °C)

A

16 21 30 40 60 77 93

Thermal current (Ith) (55 °C) 25 32 45 60 90 110 140

AC-6b current (Ie) (70 °C) 10 15 22 34 50 62 67

Max fuse (gL/gG) 25 35 50 63 100 125 160

Cable cross sectionmm2 6 6 2 x 10 16 + 16 35 + 35 35 + 35 35

AWG 10 10 2 x 7 6 + 6 2 + 2 2 + 2 2

Tightening torque N.m 1...1.7 1.6...3 2.5...4 4...6 4...6 5...6.5

Max. operation per hour ops/h. 120

Max. number of auxiliary contacts 1 3 5

Electrical lifespan Ops x 103 100

Coil consumption (AC) pick-up/sealing VA 75 / 9.3 123 / 12.5 308 / 25

Weight kg 0.619 0.670 1.370 1.389 1.7

Notes: One auxiliary contact 1NO included in CWMC contactors.

Examples of reference code: - CWMC25-10-30 ; - CWMC32-10-30 ; - CWMC50-10-30 ; - CWMC-65-10-30 .

TO COMPLETE REFERENCE CODE, REPLACE “ ” WITH APPROPRIATE COIL VOLTAGE CODE 1)

Coil voltage codes X06 X18 X32 X37 X42 X47 X50 X56

50 Hz 24 V 110 V 220 V 230-240 V 380 V 400-415 V 440 V 500 V

Coil voltage codes X04 X15 X26 X28 X30 X41 X42 X47

60 Hz 24 V 110 V 220 V 230 V 240 V 380 V 440 V 480 V

Note: 1) Other voltages on request.

Coil voltage codes (CWMC9...25) C02 C03 C07 C09 C12 C15

V dc 12 24 48 60 110 220

Coil voltage codes (CWMC32...80) C34 C37 C40 C44

V dc 24-28 42-50 110-130 208-240

Capacitor Switching Contactors - CWMC

CAPACITORS SWITCHING CONTACTORS CWMC - 75% AC COIL

CAPACITORS SWITCHING CONTACTORS CWMC - DC COIL

TYPE

RATED POWER (kVAr) STOCK CODEPRICE EACH

(ZAR)220/230 V 380/415 V C03 (24 VDC) C34 (24-28 VDC) C13 (125 VDC) C40 (110-130 VDC)

CWMC9-10-30 6 10 12713089 - 12713090 - 903,00

CWMC18-10-30 8 15 12455033 - Upon request 1) - 1129,00

CWMC25-10-30 10 15 10073592 - 11917376 - 1377,00

CWMC32-10-30 15 25 - 11109983 - 10867356 1827,00

CWMC50-10-30 25 40 - 12436588 - 11916385 5293,00

CWMC65-10-30 30 50 - 11896819 - 11916386 5816,00

CWMC80-10-30 35 61 - 12296403 - 12415463 6165,00

Note : 1) Upon Request.

For applications where there is a significant reduction on the rated voltage, sometimes due to long distances or network problems.

- Smart code of the rated voltage.

TYPE

RATED POWER (kVAr) STOCK CODE

PRICE EACH

(ZAR)220/230 V 380/415 V

X15

(95 V 50 Hz /

110 V 60 Hz)

X18

(110 V 50 Hz /

120 V 60 Hz)

X23

(180 V 50 Hz /

208 V 60 Hz)

X26

(190 V 50 Hz /

220 V 60 Hz)

X30

(208 V 50 Hz /

240 V 60 Hz)

CWMC9-10-30 6 10 12712997 12713058 12713059 12713060 12713061 586,00

CWMC18-10-30 8 15 12554137 12387955 12615375 12387956 12615376 733,00

CWMC25-10-30 10 15 11486202 11486203 11486205 11471428 11486207 879,00

CWMC32-10-30 15 25 11486216 11486217 11486219 11471896 11486221 1145,00

CWMC50-10-30 25 40 11486232 11486233 11486236 11486237 11486239 2072,00

CWMC65-10-30 30 50 11486250 11486251 11486253 11486254 11486255 2383,00

CWMC80-10-30 35 61 12256267 12615603 12615604 12256299 12615605 2740,00

TYPE

RATED POWER (kVAr) STOCK CODE

PRICE EACH

(ZAR)220/230 V 380/415 V

X32

(220 V 50 Hz /

255 V 60 Hz)

X36

(230 V 50 Hz /

266 V 60 Hz)

X37

(230-240 V 50 Hz /

277 V 60 Hz)

X41

(325 V 50 Hz /

380 V 60 Hz)

X42

(380 V 50 Hz /

440 V 60 Hz)

X47

(400-415 V 50 Hz /

480 V 60 Hz)

CWMC9-10-30 6 10 12713062 12713063 12713065 12713066 12713067 12713088 586,00

CWMC18-10-30 8 15 12615377 12615598 12615599 12615600 12615601 12615602 733,00

CWMC25-10-30 10 15 11486208 11786525 11486209 11486210 11486211 11486212 879,00

CWMC32-10-30 15 25 11486224 11921713 11486225 11486226 11486227 11486228 1145,00

CWMC50-10-30 25 40 11486241 11938936 11486242 11486244 11486245 11486246 2072,00

CWMC65-10-30 30 50 11486257 11938988 11486269 11486270 11486270 11486271 2383,00

CWMC80-10-30 35 61 12615606 12615607 12380355 12256300 12615609 12615610 2740,00

Page 59: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

114 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 115

Overload Relays

RW overload relays are important equipment within WEG Controls’ range of products. As usual for WEG

products, an extended operational service life is one of the main features found in RW overload relays.

WEG’s RW Class 10 Thermal Overload Relays are designed to be used with compact contactors and

contactors. Effectively, RW overload relays can be mounted directly to WEG compact contactors and

contactors, assuring electrical and mechanical operation as an open across-the-line starter.

Accessories are also available for separate mounting.

RW overload relays are fitted with fixed bimetallic parts, which eliminate any need for heater elements for field installation

or future upgrading to a more efficient motor. All sizes provide complete motor protection by offering:

Ambient temperature compensation

Phase failure sensitivity protection

CERTIFICATIONS

Overload Relays - Technical Data

Reference code RW17 RW27 RW67 RW117 RW317 RW407

Standards IEC/EN 60 947. DIN VDE 0660. UL. CSA IEC/EN 60 947. DIN VDE 0660

Setting current (A) 0.28...17 0.28...32 25...80 75...112 100...420 400...840

Tripping class 10

Temperature compensation Continuous

Rated insulation voltage Ui

IEC/EN 60 947/DIN VDE 0660

UL/CSA

(V)690 1000

(V) 600

Rated impulse withstand voltage Uimp

(kV) 6 8

Rated operational frequency (Hz) 0...400

Degree of protection

Protection against direct contact from the front when

actuated by a perpendicular test finger (IEC 536)

IP 20

Finger and back-of-hand proof

Ambient temperature

Operating temperature

Storage temperature

-25 oC to +60 oC

-40 oC to +70 oC

Climating proof

IEC 60 068-2-3

IEC 60 068-2-30

Damp heat. constant

Damp heat. constant

Current heat loss

Lower value of setting range

Higher value of setting range (W)

(W)

0.9

1.4

0.9

1.7

1.5

4.7

2.3

4.7

1

1.9

Terminal capacity

Solid

Flexible (stranded) without cable lug

Flexible with cable lug

Solid and stranded

Bar

Tightening torque

Main circuit

Auxiliary and control circuits

mm2

mm2

mm2

AWG

mm

Nm

Nm

2x 1.5 ... 6

2x 1.5 ... 10

2x 1.5 ... 6

14 ... 6

-

2.3

1.5

1x 6 ...35

1x 6 ...35

1x 6 ...35

18 ... 2

-

4

1.5

1x 25 ... 35

1x 25 ... 35

1x 25 ... 35

8 ... 1/0

-

6

1.5

-

-

8...1/0

2x (25x5)

16/26 1)

1.5

-

-

8...1/0

2x (60x10)

26

1.5

Reference code RW17 RW27 RW67 RW117 RW317 RW407

Rated insulation voltage Ui

IEC/EN 60 947/DIN VDE 0660 (V)

UL/CSA (V)

690

600

Rated operational current Ie

AC-15

120 V (A)

240 V (A)

415 V (A)

500 V (A)

3

2

1.5

0.5

UL/CSA C600

DC-13

24 V dc (A)

60 V dc (A)

110 V dc (A)

220 V dc (A)

1

0.5

0.25

0.1

UL/CSA R300

AUXILIARY CONTACTS

Note: 1) For RW317-1D3-U150 and RW317-1D3-U215, (ranges 100...150 A and 140...215 A, respectively) the value is 16 N.m. For RW317-1D3-U310 and RW317-

1D3-U420, (ranges 200...310 A and 275...420 A, respectively) the value is 26 N.m.

APPLICATIONS

RW thermal overload relays have been designed to protect three-phase and single-phase AC motors and direct current

motors. When the RW thermal overload relays are intended to protect single-phase AC loads or DC loads, the connection

should be made as shown in the diagrams on page 114.

RW THERMAL OVERLOAD RELAYS IN CONTACTOR ASSEMBLIES FOR WYE-DELTA DELTA STARTERS

When using thermal overload relays in conjunction with contactor assemblies for wye-delta starters, it should be taken into

consideration that only 0.58 (√3 / 3) x the motor current flows through the main contactor. An overload relay mounted on the

main contactor must be set to the same multiple of the motor current.

A second overload relay may be mounted on the wye contactor if it is desired the load to be optimally protected in wye

operation. The wye current is 1/3 of the rated motor current. The relay must then be set to this current.

Page 60: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

116 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 117

PROTECTION AGAINST SHORT-CIRCUIT

The RW thermal overload relays must be protected against short-circuits by fuses or circuit breakers.

AMBIENT AIR TEMPERATURE COMPENSATION

RW thermal overload relays are temperature compensated. Its trip point is not affected by temperature, and it performs

consistently at the same value of current. The time-current characteristics of RWs refer to a stated value of ambient air

temperature within the range of -20 °C to +60 °C and are based on no previous loading of the overload relay (i.e. from an initial

cold state). For ambient air temperature within the range of +60 °C up +80 °C (maximum ambient air temperature), the current

correction factor shown in the table below should be applied:

SITE ALTITUDE COMPENSATION

The site altitude and hence the air density play a role with respect to the cooling conditions and dielectric withstand voltage. A

site altitude of up to 2000 m is considered as normal in accordance with IEC 60947. For higher altitudes, the current settings

on the thermal overload relay should be higher than the motor rated current. On the other hand, the operational voltage must

be reduced.

For site altitudes higher than 2000 m, the values for the current and voltage shown in the table below should be applied:

PHASE FAILURE SENSITIVITY

In order to ensure fast tripping in case of phase loss, protecting the motor and avoiding expensive repairs / corrective

maintenance services, RW thermal overload relays include phase failure sensitivity protection as standard.

For this purpose, they have a differential release mechanism that, in the case of phase failure, ensures the de-energized cooled

down bimetal strip to generate an additional tripping displacement (simulating an overcurrent that actually doesn’t exist).

This way, in the event of phase failure, the differential release ensures tripping at a lower current than with a three-phase load.

However, for more effective protection against phase failure, specific protective products should be evaluated ensuring that

such failure is detected much faster.

Ambient air temperature Current correction factor

65 °C 0.94

70 °C 0.87

75 °C 0.81

80 °C 0.73

Altitude above sea level (m) Adjustment factor on the current setting Maximum operational voltage Ue (V)

2000 1.00 x In 690

3000 1.05 x In 550

4000 1.08 x In 480

5000 1.12 x In 420

The curve beside shows the tripping time in relation to the

rated current. It is also considered average values of the

tolerance range and at ambient temperature of 20 °C starting

from the cold state.

CHARACTERISTIC TRIPPING CURVE

Thermal overload relays are designed to mimic the heat

actually generated in the motor. As the motor temperature

increases, so does the temperature of the overload relay

thermal unit.

The motor and relay heating curves have a strong

relationship. No matter how high the current drawn by the

motor, the thermal overload relay provides protection and yet,

does not trip unnecessarily.

Thus, the characteristic tripping curves indicate how the

tripping time, starting from the cold state, varies with the

current for multiples of the full-load current for three-pole

symmetrical loads.

3-pole load, symmetrical

2-pole load on a 3-pole relay

Min180120906040

20

10

6

4

2

2

2 3

Sec

40

20

tA

10

10

6

6 8

5

5

4

4

601

110.6 0.8 1.5

x In

x Setting current

MULTIFUNCTION RESET / TEST BUTTON

The thermal overload relay has a multifunction RESET / TEST button that can be set in four different positions:

A - Automatic RESET only; AUTO - Automatic RESET/TEST; HAND - Manual RESET/TEST; H - Manual RESET only.

In HAND and AUTO positions, when RESET button is pressed, both NO (97-98) and NC (95-96) contacts change states.

Operation Description:

In H (Manual RESET only) or A (Automatic RESET only) position, the test function is blocked. However in the positions HAND

(manual RESET/TEST) or AUTO (Automatic RESET/TEST) it is possible to simulate the test and the trip functions by pressing

the RESET button.

When set in the H or HAND position the RESET button must be pressed manually to reset the overload relay after a tripping

event. On the other hand, when set in A or AUTO position, the overload relay will reset automatically after a tripping event.

The H, HAND, AUTO and A function setting is carried out by rotating without pressing the red button and placing it on the

desired position of the RESET button.

When changing from HAND to AUTO, the RESET button must be slightly pressed while the red button is rotated.

Functions H HAND AUTO A

Relay reset Manual 1) Manual 1) Automatic Automatic

Auxiliary contact trip test 95-96 (NC) Function is blocked Test is allowed Test is allowed Function is blocked

Auxiliary contact trip test 97-98 (NO) Function is blocked Test is allowed Test is allowed Function is blocked

Note: 1) A recovery time of a few minutes is necessary before resetting the thermal overload relay.

RECOVERY TIME

The RW thermal overload relays have thermal memory. After tripping due to an overload, the relay requires a certain period of

time for the bimetal strips to cool down. This period of time is so-called recovery time. The relay can only be reset once it has

cooled down. The recovery time depends on the characteristic tripping curves and the level of the tripping current. After

tripping due to overload, the recovery time allows the load to cool down.

OPERATION IN THE OUTPUT SIDE OF VARIABLE SPEED DRIVERS

The thermal overload relays RW17 and RW27 are designed for operation on 50/60 Hz up to 400 Hz and the tripping values are

related to the heating by currents within this frequency range. Depending on the design of the variable speed driver, the

switching frequency can reach several kHz and generate harmonic currents at the output that result in additional temperature

rise in the bimetal strips. In such applications, the temperature rise not only depends on the r.m.s. value of the current, but on

the induction effects of the higher frequency currents in the metal parts of the device (skin effect caused by eddy currents).

Due to these effects, the current settings on the overload relay should be higher than the motor rated current.

Page 61: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

118 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 119

3-Pole RW17-D Thermal Overload Relay

RW17D

TYPE RATED CURRENT DIRECT MOUNTING ON STOCK CODEPRICE EACH

(ZAR)

RW17-1D3-D004 0.28...0.4 CWC07...16 (screw) 12450892 343,00

RW17-1D3-C063 0.4...0.63 CWC07...16 (screw) 12450895 343,00

RW17-1D3-D008 0.56...0.8 CWC07...16 (screw) 12450896 343,00

RW17-1D3-D012 0.8...1.2 CWC07...16 (screw) 12450897 343,00

RW17-1D3-D018 1.2...1.8 CWC07...16 (screw) 12450898 343,00

RW17-1D3-D028 1.8...2.8 CWC07...16 (screw) 12450899 343,00

RW17-1D3-U004 2.8...4 CWC07...16 (screw) 12450900 343,00

RW17-1D3-D063 4...6.3 CWC07...16 (screw) 12450901 343,00

RW17-1D3-U008 5.6...8 CWC07...16 (screw) 12450903 343,00

RW17-1D3-U010 7...10 CWC07...16 (screw) 12450905 343,00

RW17-1D3-D125 8...12.5 CWC07...16 (screw) 12450906 343,00

RW17-1D3-U015 10...15 CWC07...16 (screw) 12450907 343,00

RW17-1D3-U017 11...17 CWC07...16 (screw) 12450908 343,00

RW17-2D3-U010 7...10 CWC025 12450909 343,00

RW17-2D3-D125 8...12.5 CWC025 12450910 343,00

RW17-2D3-U015 10...15 CWC025 12450911 343,00

RW17-2D3-U017 11...17 CWC025 12450912 343,00

RW17-2D3-U023 15...23 CWC025 12450913 356,00

RW17-2D3-U032 22...32 CWC025 12450914 356,00

3-POLE THERMAL OVERLOAD RELAY

eeeeeerrrrrrlllllllllllooooooaaaaaaddddddddddd RRRRRRRRRRRReeeeeellllllllllllaaaaayyyyy

The New Generation of WEG Components for Motor Starting and Protection

RW17D

RW27D

3-POLE THERMAL OVERLOAD RELAY

TYPE RATED CURRENT DIRECT MOUNTING ON SEPARATE MOUNTING ON STOCK CODEPRICE EACH

(ZAR)

RW17-1D3-D004 0.28...0.4 CWC07...16 (screw) - 10045638 343,00

RW17-1D3-C063 0.4...0.63 CWC07...16 (screw) - 10045639 343,00

RW17-1D3-D008 0.56...0.8 CWC07...16 (screw) - 10045640 343,00

RW17-1D3-D012 0.8...1.2 CWC07...16 (screw) - 10186034 343,00

RW17-1D3-D018 1.2...1.8 CWC07...16 (screw) - 10045641 343,00

RW17-1D3-D028 1.8...2.8 CWC07...16 (screw) - 10410001 343,00

RW17-1D3-U004 2.8...4 CWC07...16 (screw) - 10045642 343,00

RW17-1D3-D063 4...6.3 CWC07...16 (screw) - 10045643 343,00

RW17-1D3-U008 5.6...8 CWC07...16 (screw) - 10045644 343,00

RW17-1D3-U010 7...10 CWC07...16 (screw) - 10045645 343,00

RW17-1D3-D125 8...12.5 CWC07...16 (screw) - 10047029 343,00

RW17-1D3-U015 10...15 CWC07...16 (screw) - 10047030 343,00

RW17-1D3-U017 11...17 CWC07...16 (screw) - 10047031 343,00

RW17-2D3-U010 7...10 CWC025 - 10741037 343,00

RW17-2D3-D125 8...12.5 CWC025 - 10744413 343,00

RW17-2D3-U015 10...15 CWC025 - 10752610 343,00

RW17-2D3-U017 11...17 CWC025 - 10752611 343,00

RW17-2D3-U023 15...23 CWC025 - 10752612 356,00

RW17-2D3-U032 22...32 CWC025 10752613 356,00

RW27-1D3-D004 0.28...0.4 CWM 9...25 - 10045630 451,00

RW27-1D3-C063 0.43...0.63 CWM 9...25 - 10186032 451,00

RW27-1D3-D008 0.56...0.8 CWM 9...25 - 10186033 451,00

RW27-1D3-D012 0.8...1.2 CWM 9...25 - 10045631 451,00

RW27-1D3-D018 1.2...1.8 CWM 9...25 - 10045632 451,00

RW27-1D3-D028 1.8...2.8 CWM 9...25 - 10452548 451,00

RW27-1D3-U004 2.8...4 CWM 9...25 - 10452213 451,00

RW27-1D3-D063 4...6.3 CWM 9...25 - 10045633 451,00

RW27-1D3-U008 5.6...8 CWM 9...25 - 10452197 451,00

RW27-1D3-U010 7...10 CWM 9...25 - 10045634 451,00

RW27-1D3-D125 8...12.5 CWM 9...25 - 10452967 451,00

RW27-1D3-U015 10...15 CWM 9...25 - 10452384 451,00

RW27-1D3-U017 11...17 CWM 9...25 - 10452204 468,00

RW27-1D3-U023 15...23 CWM 9...25 - 10452205 468,00

RW27-1D3-U032 22...32 CWM 9...32 - 10452382 515,00

RW67-1D3-U040 25...40 CWM 32...40 - 10452216 887,00

RW67-1D3-U050 32...50 CWM 32...40 - 10452217 957,00

RW67-2D3-U040 25...40 CWM 50...80 - 10844133 957,00

RW67-2D3-U050 32...50 CWM 50...80 - 10186035 957,00

RW67-2D3-U057 40...57 CWM 50...80 - 10452201 957,00

RW67-2D3-U063 50...63 CWM 50...80 - 10452218 957,00

RW67-2D3-U070 57...70 CWM 50...80 - 10045635 1143,00

RW67-2D3-U080 63...80 CWM 50...80 - 10045636 1143,00

RW117-1D3-U080 63...80 CWM 95...105 - 10186370 1454,00

RW117-1D3-U097 75...97 CWM 95...105 - 10410002 1454,00

RW117-1D3-U112 90...112 CWM 95...105 - 10410003 1454,00

RW117-2D3-U097 75...97 - CWM 112 10045646 1758,00

RW117-2D3-U112 90...112 - CWM 112 10410004 1758,00

RW317-1D3-U150 100...150 -

CWM 112 / 150 / 180 / 250 /

300 / 400 / 500

10045647 2455,00

RW317-1D3-U215 140...215 - 10410005 2455,00

RW317-1D3-U310 200...310 - 10410006 2687,00

RW317-1D3-U420 275...420 - 10410007 2687,00

RW407-1D3-U600 400...600 - CWM 500 / 630 10452250 4241,00

RW407-1D3-U840 560...840 - CWM 630 / 800 10045637 4593,00

RW317D

3-Pole Thermal Overload Relays

RW117D

RW67D

Page 62: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

120 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 121

2-Pole RW17-D Thermal Overload Relay

2-POLE THERMAL OVERLOAD RELAY

RW17D

TYPE RATED CURRENT DIRECT MOUNTING ON STOCK CODEPRICE EACH

(ZAR)

RW17-1D2-D004 0.28...0.4 CWC07...16 (screw) 12515117 323,00

RW17-1D2-C063 0.4...0.63 CWC07...16 (screw) 12515189 323,00

RW17-1D2-D008 0.56...0.8 CWC07...16 (screw) 12515190 323,00

RW17-1D2-D012 0.8...1.2 CWC07...16 (screw) 12515192 323,00

RW17-1D2-D018 1.2...1.8 CWC07...16 (screw) 12515193 323,00

RW17-1D2-D028 1.8...2.8 CWC07...16 (screw) 12515194 323,00

RW17-1D2-U004 2.8...4 CWC07...16 (screw) 12515211 323,00

RW17-1D2-D063 4...6.3 CWC07...16 (screw) 12515213 323,00

RW17-1D2-U008 5.6...8 CWC07...16 (screw) 12515214 323,00

RW17-1D2-U010 7...10 CWC07...16 (screw) 12515215 323,00

RW17-1D2-D125 8...12.5 CWC07...16 (screw) 12515217 323,00

RW17-1D2-U015 10...15 CWC07...16 ((screw) 12515195 323,00

RW17-1D2-U017 11...17 CWC07...16 (screw) 12515208 323,00

RW17-2D2-U010 7...10 CWC025 12515216 323,00

RW17-2D2-D125 8...12.5 CWC025 12515228 323,00

RW17-2D2-U015 10...15 CWC025 12515196 323,00

RW17-2D2-U017 11...17 CWC025 12515209 323,00

RW17-2D2-U023 15...23 CWC025 12515210 334,00

RW17-2D2-U032 22...32 CWC025 12515212 334,00

eeerrrlllllloooaaadddddd RRRRRReeellllllaaayyy

The New Generation of WEG Components for Motor Starting and Protection

RW17D

2-POLE THERMAL OVERLOAD RELAY

TYPE RATED CURRENT DIRECT MOUNTING ON STOCK CODEPRICE EACH

(ZAR)

RW17-1D2-D004 0.28...0.4 CWC07...16 (screw) 10076070 323,00

RW17-1D2-C063 0.4...0.63 CWC07...16 ((screw) 10076071 323,00

RW17-1D2-D008 0.56...0.8 CWC07...16 (screw) 10647531 323,00

RW17-1D2-D012 0.8...1.2 CWC07...16 (screw) 10076072 323,00

RW17-1D2-D018 1.2...1.8 CWC07...16 (screw) 10076073 323,00

RW17-1D2-D028 1.8...2.8 CWC07...16 (screw) 10186772 323,00

RW17-1D2-U004 2.8...4 CWC07...16 (screw) 10047198 323,00

RW17-1D2-D063 4...6.3 CWC07...16 (screw) 10076074 323,00

RW17-1D2-U008 5.6...8 CWC07...16 (screw) 10212774 323,00

RW17-1D2-U010 7...10 CWC07...16 (screw) 10076075 323,00

RW17-1D2-D125 8...12.5 CWC07...16 (screw) 10076076 323,00

RW17-1D2-U015 10...15 CWC07...16 (screw) 10076077 323,00

RW17-1D2-U017 11...17 CWC07...16 (screw) 10076078 323,00

RW17-2D2-U010 7...10 CWC025 10794499 323,00

RW17-2D2-D125 8...12.5 CWC025 10794502 323,00

RW17-2D2-U015 10...15 CWC025 10794506 323,00

RW17-2D2-U017 11...17 CWC025 10794508 323,00

RW17-2D2-U023 15...23 CWC025 10794511 334,00

RW17-2D2-U032 22...32 CWC025 10794513 334,00

RW27-1D2-D004 0.28...0.43 CWM 9...25 10076079 424,00

RW27-1D2-C063 0.43...0.63 CWM 9...25 10076080 424,00

RW27-1D2-D008 0.56...0.8 CWM 9...25 10076081 424,00

RW27-1D2-D012 0.8...1.2 CWM 9...25 10076082 424,00

RW27-1D2-D018 1.2...1.8 CWM 9...25 10047199 424,00

RW27-1D2-D028 1.8...2.8 CWM 9...25 10047200 424,00

RW27-1D2-U004 2.8...4 CWM 9...25 10076083 424,00

RW27-1D2-D063 4...6.3 CWM 9...25 10047201 424,00

RW27-1D2-U008 5.6...8 CWM 9...25 10047202 424,00

RW27-1D2-U010 7...10 CWM 9...25 10186773 424,00

RW27-1D2-D125 8...12.5 CWM 9...25 10047203 424,00

RW27-1D2-U015 10...15 CWM 9...25 10047204 424,00

RW27-1D2-U017 11...17 CWM 9...25 10047205 440,00

RW27-1D2-U023 15...23 CWM 9...25 10047206 440,00

RW27-1D2-U032 22...32 CWM 9...32 10047207 484,00

RW67-1D2-U040 25...40 CWM 32...40 10047208 834,00

RW67-1D2-U050 32...50 CWM 32...40 10047209 900,00

RW67-2D2-U057 40...57 CWM 50...80 10047210 900,00

RW67-2D2-U063 50...63 CWM 50...80 10047211 900,00

RW67-2D2-U070 57...70 CWM 50...80 10047212 1074,00

RW67-2D2-U080 63...80 CWM 50...80 10647542 1074,00

2-Pole Thermal Overload Relays

RW27D

RW67D

Page 63: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

122 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 123

Accessories for Thermal Overload Relay

SET OF TERMINALS FOR CONNECTION

BASE FOR SEPARATE MOUNTING

EXTERNAL RESET FOR OVERLOAD RELAYS

TYPE TO USE WITH STOCK CODEPRICE EACH

(ZAR)

GA 67-1D RW67D + CWM 32 / 40 10186061 397,00

GA 67-2D RW67D + CWM 50 / 65 / 80 10186062 397,00

GA117D RW117.2D + CWM112 10185899 490,00

GA-317-1D RW317D + CWM150 10185904 355,00

GA-317-2D RW317D + CWM180 10185900 355,00

GA-317-3D RW317D + CWM250/300 10185901 644,00

GA-317-10D RW317D + CWM400 10187159 859,00

TYPE TO USE WITH STOCK CODEPRICE EACH

(ZAR)

A17 RW17 10045695 19,00

BF27D RW27-1D 10410085 79,00

BF67-1D RW67-1D 10410086 178,00

BF67-2D RW67-2D 10046505 178,00

BF117D RW117-1D 10045719 205,00

TYPE TO USE WITH FLEXIBLE CABLE SIZE STOCK CODEPRICE EACH

(ZAR)

ERC250RW RW17 to RW407 (all models) 250 mm 11795102 560,00

ERC375RW RW17 to RW407 (all models) 375 mm 11795097 577,00

ERC500RW RW17 to RW407 (all models) 500 mm 11795105 594,00

Note : Quantity per packing: 3 units.

Solid-State Overload Relays 123

Solid-State Overload Relays - RW_E

SOLID-STATE X THERMAL (BIMETALLIC) OVERLOAD RELAYS

Thermal overload relays are designed to mimic the heat actually generated in the motor. They simulate the motor heating by passing

motor current directly or indirectly through bimetal strips. As the motor temperature increases, so does the temperature of the

overload relay thermal unit. The heat bends the bimetal strips and, depending on the current setting of the relay, a trip mechanism is

activated.

Continuous duty and low number of motor start-ups are common in most usual applications. In such situations, the motor and relay

heating curves have a strong relationship. No matter how high the current drawn by the motor, the thermal overload relay provides

protection and does not trip unnecessarily.

On the other hand, in applications where frequent motor start-ups (intermittent duty) take

place, the increase of heating behaves slightly different in the bimetal strips than in the motor

windings and undesired early trippings are common. In such situations, the thermal capacity

of the motor is not properly utilized and thermal overload relays are not the most suitable

solution.

In solid-state overload relays, the motor current is measured by current transformers and then

converted into an electronic signal. Thus, different from thermal overload relays where a

significant amount of energy is wasted in the bimetal strips, in solid-state overload relays the

low heat losses of the electronic circuits result in less energy consumption and lead to

reduced need of ventilation of cabinets.

In addition, due to this technology, the microprocessed signal allows increased precision

providing better motor overload protection.

And yet, maybe the most important advantage of solid-state overload relays is the wide

current range with the 5:1 ratio between maximum and minimum setting.

When compared to the usual 1.5:1 ratio of the thermal overload relays, this wide range leads

to a tremendously reduced number of different items to cover all current ranges up to 840 A.

In a few words, it leads to great reduction in inventory and flexibility on planning.

wwwww..zestt.coo.zzaa

yss RRRWWW EEE

the motor heat

The New Generation of WEG Components for Motor Starting and Protection

Page 64: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

124 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 125

In an increasingly globalized and competitive market it is common that machine manufacturers provide their customers with

a wide choice of electric motors with a huge number of different models and output powers.

With its wide range current setting (5:1 ratio between maximum and minimum setting), the same RW_E relay can be used

for protection of electric motors of different power ratings or for protection of the same motor when applied on networks of

different voltages and frequencies. The benefit is versatility and flexibility for machine manufacturers due to the possibility of

standardization of control panels.

FLEXIBILITY AND VERSATILITY

The RW_E can be directly mounted on WEG contactors (CWB and CWM lines) providing

very reliable and flexible motor starter units.

An additional advantage is that the solid-state overload relays RW_E are self-powered,

that is, no additional external power is required for operation thus it can be applied directly

to the contactor in the same way the thermal overload relays are applied. This feature also

allows easy replacement of thermal relays for solid-state ones without the need of

rearranging the control circuit wiring or changing the contactor.

Note: overload relays must be protected against short-circuits by fuses or circuit breakers.

Detail of the current

setting dial

9 solid-state overload relay models

840 A0.4 A

Versus

28 thermal overload relay models

AVAILABLE PROTECTIONS

Overload Phase unbalance Phase loss

L1 L1L2

L2

L3

L3XAI ≤seg.

I1 I2 I3

(>40%)

Solid-State Overload Relays - RW_E

BASIC FEATURES

The RW_E counts on two independent and highly reliable built-in auxiliary contacts (12 V, 10 mA) that, when properly wired

in series with the coil of the contactor, assure the motor is switched off when a failure occurs and can also be used for

monitoring purposes.

On its front side the RW_E has a RESET pushbutton and a TEST switch. Both functions allow checking proper wiring and

the status of the auxiliary contacts. The status window (TRIP) that displays the current operation status is also located on

the front side.

Solid-State Overload Relays - RW_E

Due to their design and technology, the electronic circuits of

RW_E relays lead to very low power dissipation (less than

0.38 W up to 25 A) and consequently may contribute to the

reduction of need for ventilation of control cabinets.

Bimetallic

overload relays

Solid-state

overload relays

Power dissipation1) (W)

<87%

RESET type selector TEST function and

TRIP status

Auxiliary contacts for control

and monitoring purposes

Note: 1) Average values of power dissipation per pole for RW_E of current ranges up to 25 A.

Page 65: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

126 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 127

The solid-state overload relays RW_E are suitable to protect motors in a wide range of industrial applications including those where

long starting time is required. This way, motors on low, medium or heavy duty applications can be properly protected just by

selecting the proper trip class (10, 20 or 30 according to IEC 60947-4-1) in the DIP-switches.

Additionally, the microprocessed electronic circuits of RW_E are temperature compensated according to IEC 60947-4-1, which

means that throughout the temperature range of -20 °C up to +60 °C, the tripping point is not affected and it performs consistently

without undesirable tripping.

The RW_E also features thermal memory which assures that the heating and cooling effects of motors are modeled and proper

protection is guaranteed even after downtime periods.

SUITABLE FOR GREAT VARIETY OF APPLICATIONS

Trip class dip-switch

IEC 60947-4-1

Trip

pin

g t

ime

Ie x Current setting

(A)

t(s)

10.800

10.000

5.000

2.000

1.000

500

200

100

50

20

10

5

2

11.05 1.5 2 3 4 5 6 7 8 9 10

Trip class 30

Trip class 20

Trip class 10

Trip classMultiples of current setting

1.05 x Ir 1.2 x Ir 1.5 x Ir 7.2 x Ir

10 - Tp <2 h Tp <4 min 4 <Tp ≤10 s

20 - Tp <2 h Tp <8 min 6 <Tp ≤20 s

30 - Tp <2 h Tp <12 min 9 <Tp ≤30 s

Solid-State Overload Relays - RW_E

MAIN CONTACTS

Technical Data

Product model RWM40E / RWB40E RWM112E RWM420E RWM840E

Rated operational voltage Ue

IEC 60947-4-1 (V) 690 1,000

Current setting / max fuse (gL/gG) (A)

0.4...2 / 16

1.6...8 / 32

5...25 / 63

8...40 / 125

14...56 / 160

28....112 / 250

50...250 / 500

85...420 / 710 170...840 / 1.250

Setting current / average power dissipation per pole (W)

0.4...2 / 0.07

1.6...8 / 0.06

5...25 / 0.38

8...40 / 1.5

14...56 / 2

28....112 / 2.6

50...250 / 12

85...420 / 12170...840 / 14.5

Notes: 1) Direct mounting on contactor or directly on the panel via screws or 35 mm DIN rail when using the mounting kit accessory (BF27D and BF112);

2) Direct mounting on contactor when using the Connector Link GA117 / GA317 accessory or directly on the panel via screws.

Notes: 1) Direct mounting on contactor or directly on the panel via screws or 35 mm DIN rail when using the mounting kit accessory (BF27D and BF112);

2) Direct mounting on contactor when using the Connector Link GA117 / GA317 accessory or directly on the panel via screws.

Product model RWM40E / RWB40E RWM112E RWM420E RWM840E

Standards IEC 60947-4-1, IEC 60947-5-1, IEC 60947-1, UL 60947-1, UL 60947-4-1A and UL 508

Rated insulation voltage Ui

(pollution degree 3)IEC 60947-4-1 (V) 690 1.000

Rated impulse withstand voltage Uimp

(IEC 60947-1) (kV) 6 8

Rated operational frequency (sinusoidal networks) (Hz) 50/60

Suitable for use

Three phase loads Yes

Single phase / two phase loads No

DC current loads No

Trip class (IEC 60947-4-1) 10, 20 or 30 - selectable

Additional featured protectionsPhase loss Yes / less than <5 s

Phase unbalance Yes / >40%

ResetManual / minimum downtime for reset Yes / instantaneous

Automatic / minimum downtime for reset Yes / ≥90 s

Maximum operation per hour (ops./h) 30

Protection degree (IEC 60529) Main contacts IP10 IP00

Auxiliary contacts IP20

Mounting 1) 2)

Mechanical shock resistance - 1/2 sinusoid 15 g / 11 ms

Vibration resistance (IEC 60068-2-6) 6 g / 30...300 Hz

Ambient temperature

Transport and storage -50 ºC...+80 ºC

Operating -20 ºC...+60 ºC

Temperature compensation -20 ºC...+60 ºC

Altitude 2,000 m

GENERAL DATA

Page 66: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

128 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 129

RW_E Solid-State Overload Relays from 0.4 up to 840 A

3-pole solid state overload relays with adjustable trip

class: 10, 20 and 30 Self-powered Wide adjustment range (5:1) Thermal memory Phase loss protection (less than 5 seconds)

For direct mounting

on contactors

Current range

ADiagram

Max fuse

(gL/gG)

A

Reference codeWeight

kg

CWB9...38 0.4...2

1L1

2T1

5L3 95

96

97

98

Reset

Test

4T2 6T3

3L2

16 RWB40E-3-A4U002

0.250CWB9...38 1.6...8 32 RWB40E-3-A4U008

CWB9...38 5...25 63 RWB40E-3-A4U025

CWB9...38 8...40 125 RWB40E-3-A4U040

CWM9...40 0.4...2 16 RWM40E-3-A4U002

0.250CWM9...40 1.6...8 32 RWM40E-3-A4U008

CWM9...40 5..25 63 RWM40E-3-A4U025

CWM9...40 8...40 125 RWM40E-3-A4U040

CWM50...105 14...56 160 RWM112E-3-A4U0560.918

CWM50...105 28...112 250 RWM112E-3-A4U112

For separate mounting or by

connector links1)

Current range

ADiagram

Max fuse

(gL/gG)

A

Reference codeWeight

kg

CWM112...500

50...250

1L1

2T1

5L3 95

96

97

98

Reset

Test

4T2 6T3

3L2

500 RWM420E-3-A4U250

2,520

85...420 710 RWM420E-3-A4U420

CWM150...800 170....840 1.250 RWM840E-3-A4U840 4,150

Phase unbalance protection (>40% between phases) Temperature compensated (-20 °C up to +60 °C) Manual or automatic reset modes Direct mounting on CWB9...38 and CWM9...105 contactors Separate mounting is possible with accessories 1NO + 1NC built in auxiliary contacts

Note: 1) RWM840E model allows two different types of connection to contactor:

a) By connecting the contactor cables to relay busbars;

b) By removing the relay busbars and using the Ø32 mm window for the passage of the contactor cables.

Technical Data

AUXILIARY CONTACTS

Product model RWM40...840E / RWB40E

Standards IEC 60947-5-1

Rated insulation voltage Ui

(pollution degree 3)IEC (V) 250

Rated impulse withstand voltage Uimp

(IEC 60947-1) (kV) 4

Rated operational voltage Ue

IEC (V) 250

Rated thermal current Ith ( ≤ 60 ºC) (A) 5

Rated operational current Ie

AC-14/AC-15 (IEC 60947-5-1)

24 V (A) 3

120 V (A) 3

250 V (A) 1.5

DC-13 (IEC 60947-5-1)

24 V (A) 2

60 V (A) 0.4

110 V (A) 0.22

125 V (A) 0.22

250 V (A) 0.1

Short-circuit protection with fuse (A) 6

Minimum voltage / admissible current (IEC 60947-5-4) 12 V / 10 mA

TERMINAL CAPACITY AND TIGHTENING TORQUE - AUXILIARY CONTACTS

Product model RWM40...840E / RWB40E

Type of screwFlat / Phillips

#1

Cable size

Cable with or without terminal (mm²) 1 x 1...2.5

AWG wire 16...12

Tightening torque (Nm) 0.8

Product model BF27D RWM40E / RWB40E RW112E BF112

Type of screwM4 M3.5 M10 M10

Flat / Phillips #2 Flat / Phillips #2 Allen #4 Allen #4

Cable size

Flexible cable (mm²) 1.5...10 - - -

Cable with terminal / rigid cable (mm²) 1.5...6 - - -

AWG wire 16...10 - - -

Tightening torque (Nm) 2.3 - - -

Flexible cable (mm²) - 1...10 2.5...35 2.5...35

Cable with terminal / rigid cable (mm²) - 1...10 2.5...35 2.5...35

AWG wire - 16...8 14...2 14...2

Tightening torque (Nm) - 1.7 6 6

Product model RWM420E RWM840E

Type of screw

M10Hexagon Head

M12

Hexagon Head

Cable with terminal (mm²) 2 x (25...150) 2 x (60 x 10)

Busbar (A x B x C) (mm) 25 x 18.5 x 12.5 31.7 x 28.3 x 15

Tightening torque (Nm) 26 26

TERMINAL CAPACITY AND TIGHTENING TORQUE - MAIN CONTACTS

A

C

B

Page 67: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

130 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 131

Solid-State Overload Relays RW_40...840E - Overview

1

2

3

4

5

6

7

8

9

- RWM40E solid-state overload relay (direct mounting on CWM9...40 contactors)

- RWM112E solid-state overload relay (direct mounting on CWM50...105 contactors)

- RWM420E solid-state overload relay (for use with CWM112...500 contactors)

- RWM840E solid-state overload relay (for use with CWM400...800 contactors)

- BF27 mounting kit for direct panel mounting by screws or 35 mm DIN rail (for RWM40E)

- BF112 mounting kit for direct panel mounting by screws or 35 mm DIN rail (for RWM112E)

- GA Connector Links for direct mounting of overload relay on contactor

- IBRW317 phase barriers (for RWM420E)

- RWB40E solid-state overload relay (direct mounting on CWB9...38 contactors)

3

7

1

5

4

6

8

9

2

TYPE RATED CURRENT DIRECT MOUNTING ON STOCK CODEPRICE EACH

(ZAR)

RWM40E-3-A4U002 0,4-2 A

CWM9-25

11454460 1 811,00

RWM40E-3-A4U008 1,6-8 A 11454459 1 811,00

RWM40E-3-A4U025 5-25 A 11454417 1 811,00

RWM40E-3-A4U040 8-40 A CWM32...40 11373597 1 811,00

RWM112E-3-A4U056 14-56 A CWM50...105

CWM112

11114728 1 884,00

RWM112E-3-A4U112 28-112 A 11114729 1 884,00

RWM420E-3-A4U250 50-250 ACWM112...400

12802652 4 244,00

RWM420E-3-A4U420 112-420 A 11455846 6 971,00

RWM840E-3-A4U840 170-840 A CWM500...800 11455847 10 988,00

RWB40E-3-A4U002 0,4-2 A

CWB9-38

12786062 1 811,00

RWB40E-3-A4U008 1,6-8 A 12786061 1 811,00

RWB40E-3-A4U025 5-25 A 12786060 1 811,00

WB40E-3-A4U040 8-40 A 12786059 1 811,00

FIXING BASE BF112 - RWM112E 10806502 281,00

Solid-State Overload Relays RW_E

Page 68: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

132 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 133

Motor Protective Circuit Breakers MPW

OverviewWith the latest technology and design, the MPW series saves panel space and can be used in most applications in

motor control.

It combines short-circuit and motor overload protections in just one component. These devices include a three-position

rotary ON-TRIP-OFF handle, which can be padlocked in the OFF position.

MPW16 up to 16 A / MPW12_S up to 12 A MPW25 up to 32 A

Gen

eral

tec

hnic

al d

ata

Maximum rated current Imax

(Iu) 16 A (screw terminals) 12 A (spring terminals) 32 A

Number of poles 3 3

Short-circuit release 13 x lu max 13 x l

u max 13 x l

u max 13 x l

u max 19 x l

u max

Rated operational voltage Ue

690 V 690 V 690 V 690 V 690 V

Rated frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz

Utilization

category

IEC 60 947-2 (circuit breaker) A A A A A

IEC 60 947-4-1 (motor starter) AC-3 AC-3 AC-3 AC-3 AC-3

Tripping test Yes Yes Yes Yes Yes

Overload protection Yes No Yes No Yes

Phase failure sensitivity Yes No Yes No Yes

Tripping indication Yes Yes Yes Yes Yes

Tripping Class 10 - 10 - 10

Mechanical life Number of operations 100,000 100,000 100,000 100,000 100,000

Electrical life Number of operations 100,000 100,000 100,000 100,000 100,000

Temperature compensation -20...+60 °C - -20...+60 °C - -20...+60 °C

Type of protection Thermomagnetic Magnetic Thermomagnetic Magnetic Thermomagnetic

Setting overload release

Ir(A)

Reference code Reference code

Terminal type Screw Spring Screw Spring Screw

0.1...0.16 MPW16-3-C016 MPW12-3-C016S MPW16i-3-C016 MPW12i-3-C016S MPW25-3-C016 MPW25i-3-C016 MPW25t-3-C016

0.16...0.25 MPW16-3-C025 MPW12-3-C025S MPW16i-3-C025 MPW12i-3-C025S MPW25-3-C025 MPW25i-3-C025 MPW25t-3-C025

0.25...0.4 MPW16-3-D004 MPW12-3-D004S MPW16i-3-D004 MPW12i-3-D004S MPW25-3-D004 MPW25i-3-D004 MPW25t-3-D004

0.4...0.63 MPW16-3-C063 MPW12-3-C063S MPW16i-3-C063 MPW12i-3-C063S MPW25-3-C063 MPW25i-3-C063 MPW25t-3-C063

0.63...1 MPW16-3-U001 MPW12-3-U001S MPW16i-3-U001 MPW12i-3-U001S MPW25-3-U001 MPW25i-3-U001 MPW25t-3-U001

1...1.6 MPW16-3-D016 MPW12-3-D016S MPW16i-3-D016 MPW12i-3-D016S MPW25-3-D016 MPW25i-3-D016 MPW25t-3-D016

1.6...2.5 MPW16-3-D025 MPW12-3-D025S MPW16i-3-D025 MPW12i-3-D025S MPW25-3-D025 MPW25i-3-D025 MPW25t-3-D025

2.5...4 MPW16-3-U004 MPW12-3-U004S MPW16i-3-U004 MPW12i-3-U004S MPW25-3-U004 MPW25i-3-U004 MPW25t-3-U004

4...6.3 MPW16-3-D063 MPW12-3-D063S MPW16i-3-D063 MPW12i-3-D063S MPW25-3-D063 MPW25i-3-D063 MPW25t-3-D063

6.3...10 MPW16-3-U010 MPW12-3-U010S MPW16i-3-U010 MPW12i-3-U010S MPW25-3-U010 MPW25i-3-U010 MPW25t-3-U010

8...12 - MPW12-3-U012S - MPW12i-3-U012S - - -

10...16 MPW16-3-U016 MPW16i-3-U016

-

MPW25-3-U016 MPW25i-3-U016 MPW25t-3-U016

16...20

- -

MPW25-3-U020 MPW25i-3-U020 MPW25t-3-U020

20...25 MPW25-3-U025 MPW25i-3-U025 -

25...32 MPW25-3-U032 MPW25i-3-U032 -

MPW65 up to 65 A MPW100 up to 100 A

Gen

eral

tec

hnic

al d

ata

Maximum rated current Imax

(Iu) 65 A 100 A

Number of poles 3 3

Short-circuit release 13 x lu max 13 x l

u max 13 x l

u max

Rated operational voltage Ue

690 V 690 V 690 V

Rated frequency 50/60 Hz 50/60 Hz 50/60 Hz

Use categoryIEC 60 947-2 (circuit breaker) A A A

IEC 60 947-4-1 (motor starter) AC-3 AC-3 AC-3

Tripping test Yes Yes Yes

Overload protection Yes No Yes

Phase failure sensitivity Yes No Yes

Tripping indication Yes Yes Yes

Tripping class 10 - 10

Mechanical life Number of operations 50,000 50,000 50,000

Electrical life Number of operations 25,000 25,000 25,000

Temperature compensation -20...+60 °C - -20...+60 °C

Type of protection Thermomagnetic Magnetic Thermomagnetic

Setting overload release

Ir(A)

Reference code Reference code

Terminal type Screw Screw

0.1...0.16

- -

-

0.16...0.25

0.25...0.4

0.4...0.63

0.63...1

1...1.6

1.6...2.5

2.5...4

4...6.3

6.3...10

8...12

10...16

16...20

20...25

25...32

32...40 MPW65-3-U040 MPW65i-3-U040

40...50 MPW65-3-U050 MPW65i-3-U050

50...65 MPW65-3-U065 MPW65i-3-U065

55...75

- -

MPW100-3-U075

70...90 MPW100-3-U090

80...100 MPW100-3-U100

Designed for DIN rail mounting, while lugs for direct panel mounting are also available as accessory.

MPW Motor Protective Circuit Breakers are available in five models: MPW16/MPW12_S/MPW25 (45 mm), MPW65 (54 mm) and

MPW100 (70 mm) and have been designed for use according to international standards, making them suitable for applications

all over the world.

Motor Protective Circuit Breakers MPW - Overview

Page 69: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

134 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 135

Motor Protective Circuit Breakers MPW16 / MPW12_S - Overview

1 - Motor protective circuit breaker MPW16

2 - Feeder terminal FTBBS

3 - Three-phase busbars BBS

4 - Push-in-lugs PLMP

5 - Side auxiliary contact block ACBS

6 - Undervoltage release URMP or shunt release SRMP

7 - Front auxiliary contact block ACBF

8 - Connector ECCMP-C016 (MPW16 + CWC07…16)

9 - Compact contactors CWC07…16

10 - Insulated enclosure

11 - Block module for power terminals to printed circuit board

12 - Block module for auxiliary frontal contact block to printed

circuit board

13 - Scale cover SCMP

14 - Trip signalling block TSB

15 - FESTPE twist release emergency pushbutton

16 - Motor protective circuit breaker MPW12_S

17 - Side auxiliary contact block ACBS_S

18 - Front auxiliary contact block ACBF_S

r Protective Circuit Breakers MPW16 / MPW12_S Overv

1

9

8

2

3

4 6

1

7

10

4

11

12

13

1

5

14

15

4

16

1817

44

16

1817

Motor Protective Circuit-Breaker MPW16 - Screw Type

TYPE RATED CURRENT STOCK CODEPRICE EACH

(ZAR)

MPW16-3-C016 0.10 - 0.16 10127976 512,00

MPW16-3-C025 0.16 - 0.25 10126881 512,00

MPW16-3-D004 0.25 - 0.40 10126880 512,00

MPW16-3-C063 0.40 - 0.63 10126879 522,00

MPW16-3-U001 0.63 - 1.0 10127983 528,00

MPW16-3-D016 1.0 - 1.6 10127982 528,00

MPW16-3-D025 1.6 - 2.5 10127981 528,00

MPW16-3-U004 2.5 - 4.0 10127980 528,00

MPW16-3-D063 4.0 - 6.3 10127979 528,00

MPW16-3-U010 6.3 - 10 10127977 614,00

MPW16-3-U016 10 - 16 10127978 614,00

TYPE RATED CURRENT STOCK CODEPRICE EACH

(ZAR)

MPW16i-3-C016 0.16 10583766 497,00

MPW16i-3-C025 0.25 10583767 497,00

MPW16i-3-D004 0.4 10583768 497,00

MPW16i-3-C063 0.63 10583769 499,00

MPW16i-3-U001 1 10583770 515,00

MPW16i-3-D016 1.6 10583771 515,00

MPW16i-3-D025 2.5 10583772 515,00

MPW16i-3-U004 4 10583773 515,00

MPW16i-3-D063 6.3 10583774 515,00

MPW16i-3-U010 10 10583775 614,00

MPW16i-3-U016 16 10583776 614,00

MPW16 - THERMAL-MAGNETIC PROTECTION

MPW16I - MAGNETIC PROTECTION

Page 70: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

136 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 137

Motor Protective Circuit-Breaker MPW16 - Spring Type

TYPE RATED CURRENT STOCK CODEPRICE EACH

(ZAR)

MPW16-3-C016S 0.10 - 0.16 11641578 563,00

MPW16-3-C025S 0.16 - 0.25 11642460 563,00

MPW16-3-D004S 0.25 - 0.40 11642461 563,00

MPW16-3-C063S 0.40 - 0.63 11642462 574,00

MPW16-3-U001S 0.63 - 1.0 11642464 581,00

MPW16-3-D016S 1.0 - 1.6 11642465 581,00

MPW16-3-D025S 1.6 - 2.5 11642466 581,00

MPW16-3-U004S 2.5 - 4.0 11642467 581,00

MPW16-3-D063S 4.0 - 6.3 11642469 581,00

MPW16-3-U010S 6.3 - 10 11642470 675,00

MPW16-3-U012S 8 - 12 11643531 675,00

TYPE RATED CURRENT STOCK CODEPRICE EACH

(ZAR)

MPW16i-3-C016S 0.16 11642476 546,00

MPW16i-3-C025S 0.25 11642498 546,00

MPW16i-3-D004S 0.4 11642499 546,00

MPW16i-3-C063S 0.63 11642500 549,00

MPW16i-3-U001S 1 11642501 566,00

MPW16i-3-D016S 1.6 11642502 566,00

MPW16i-3-D025S 2.5 11642503 566,00

MPW16i-3-U004S 4 11642504 566,00

MPW16i-3-D063S 6.3 11642505 566,00

MPW16i-3-U010S 10 11642506 675,00

MPW16i-3-U012S 12 11643535 675,00

MPW16_S - THERMAL-MAGNETIC PROTECTION

MPW16I_S - THERMAL-MAGNETIC PROTECTION

Motor Protective Circuit Breaker MPW25 - Overview

1 - Motor protective circuit breaker MPW25

2 - Feeder terminal FTBBS

3 - Three-phase busbars BBS

4 - Push-in-lugs PLMP

5 - Side auxiliary contact block ACBS

6 - Undervoltage release URMP or shunt release SRMP

7 - Front auxiliary contact block ACBF

8 - Door coupling rotary handle RMMP

9 - Connector ECCMP-25 (MPW25 + CWM9...25)

10 - Contactors CWM9...25

11 - Door coupling rotary handle MRX

12 - Front plate FME55

13 - Standard insulated enclosure MPE55

14 - Large insulated enclosure MLPE55

15 - Trip signalling block TSB

16 - Connector ECCMP-32 (MPW25 + CWM32...40)

17 - Contactors CWM32...40

18 - Connector ECCMP-C025 (MPW25 + CWC025)

19 - Compact contactor CWC025

20 - Feeder terminal for “Type E” motor starter according to UL LST25

21 - Connector ECCMP-C0 (MPW25 + CWC07...16)

22 - Compact contactor CWC07...16

23 - Current limiter CLT25

24 - Scale cover SCMP

12

13

1

1

1

18

16

19

1017

9

1

7

8

155

1

6

23

4

4

21

13

22

20

23

14

11

1

24

Page 71: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

138 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 139

Motor Protective Circuit-Breaker MPW25 - Screw Type

TYPE RATED CURRENT STOCK CODEPRICE EACH

(ZAR)

MPW25-3-C016 0.10 - 0.16 10045306 602,00

MPW25-3-C025 0.16 - 0.25 10045307 602,00

MPW25-3-D004 0.25 - 0.40 10045308 602,00

MPW25-3-C063 0.40 - 0.63 10045309 614,00

MPW25-3-U001 0.63 - 1.0 10409813 621,00

MPW25-3-D016 1.0 - 1.6 10409814 621,00

MPW25-3-D025 1.6 - 2.5 10409815 621,00

MPW25-3-U004 2.5 - 4.0 10409816 621,00

MPW25-3-D063 4.0 - 6.3 10409817 621,00

MPW25-3-U010 6.3 - 10 10409818 722,00

MPW25-3-U016 10 - 16 10409819 722,00

MPW25-3-U020 16 - 20 10409820 778,00

MPW25-3-U025 20 - 25 10045310 921,00

MPW25-3-U032 25 - 32 10410323 990,00

TYPE RATED CURRENT STOCK CODEPRICE EACH

(ZAR)

MPW25i-3-C016 0.16 10045311 584,00

MPW25i-3-C025 0.25 10045312 584,00

MPW25i-3-D004 0.4 10185913 584,00

MPW25i-3-C063 0.63 10185914 587,00

MPW25i-3-U001 1 10045313 606,00

MPW25i-3-D016 1.6 10045314 606,00

MPW25i-3-D025 2.5 10045315 606,00

MPW25i-3-U004 4 10045316 606,00

MPW25i-3-D063 6.3 10045317 606,00

MPW25i-3-U010 10 10045318 703,00

MPW25i-3-U016 16 10045319 703,00

MPW25i-3-U020 20 10045320 742,00

MPW25i-3-U025 25 10045321 884,00

MPW25i-3-U032 32 10046500 950,00

MPW25 - THERMAL-MAGNETIC PROTECTION

MPW25I - MAGNETIC PROTECTION

TYPE RATED CURRENT STOCK CODEPRICE EACH

(ZAR)

MPW25t-3-C016 0.10 - 0.16 10075057 843,00

MPW25t-3-C025 0.16 - 0.25 10075058 843,00

MPW25t-3-D004 0.25 - 0.40 10075059 843,00

MPW25t-3-C063 0.40 - 0.63 10075060 860,00

MPW25t-3-U001 0.63 - 1.0 10075061 869,00

MPW25t-3-D016 1.0 - 1.6 10075062 869,00

MPW25t-3-D025 1.6 - 2.5 10075063 869,00

MPW25t-3-U004 2.5 - 4.0 10075064 869,00

MPW25t-3-D063 4.0 - 6.3 10075065 869,00

MPW25t-3-U010 6.3 - 10 10075066 1011,00

MPW25t-3-U016 10 - 16 10075067 1011,00

MPW25t-3-U020 16 - 20 10075068 1089,00

MPW25T - THERMAL-MAGNETIC PROTECTION (IM = 19XI

N)

Motor Protective Circuit Breaker MPW65 and MPW100 - Overview

1 - Motor protective circuit breaker MPW65

2 - Push-in-lugs PLMP

3 - Side auxiliary contact block ACBS

4 - Undervoltage release URMP or shunt release SRMP

5 - Frontal auxiliary contact block ACBF

6 - Trip signalling block TSB

7 - Door coupling rotary handle MRX65

8 - Door coupling rotary handle RMMP65

9 - Scale cover SCMP

10 - Feeder terminal for “Type E” motor starter according to

UL LST65

11 - Motor protective circuit breaker MPW100

12 - IB insulators

13 - Side auxiliary contact block ACBS_ MPW100

14 - Undervoltage release URMP_ MPW100 or shunt release

SRMP_ MPW100

15 - Frontal auxiliary contact block ACBF_ MPW100

16 - Trip signalling block TSB_ MPW100

17 - Door coupling rotary handle MR MPW100

18 - Door coupling rotary handle MRX100

1

5

6

2

2

3

4

7

8

9

10

13

16

11

12

15

14

17

18

Page 72: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

140 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 141

Motor Protective Circuit-Breaker MPW65 - Screw Type

Motor Protective Circuit-Breaker MPW100 - Screw Type

TYPE RATED CURRENT STOCK CODEPRICE EACH

(ZAR)

MPW65-3-U040 32-40 10583780 2270,00

MPW65-3-U050 40-50 10583781 2364,00

MPW65-3-U065 50-65 10306746 2364,00

TYPE RATED CURRENT STOCK CODEPRICE EACH

(ZAR)

MPW100-3-U075 55-75 10076551 3907,00

MPW100-3-U090 70-90 10076552 4202,00

MPW100-3-U100 80-100 10047295 4202,00

TYPE RATED CURRENT STOCK CODEPRICE EACH

(ZAR)

MPW65i-3-U040 40 10583761 2202,00

MPW65i-3-U050 50 10583762 2293,00

MPW65i-3-U065 65 10583763 2293,00

MPW65 - THERMAL-MAGNETIC PROTECTION

MPW100 - THERMAL-MAGNETIC PROTECTION

MPW65I - MAGNETIC PROTECTION

Note : Some motors characteristics may vary according to each manufacturer.

Altitude

(above sea level) - h

Rated operational voltage

Ue

Current correction factor

Iu

h ≤ 2000 m 690 V 1 x Iu

2000 < h ≤ 3000 m 550 V 0.96 x Iu

3000 < h ≤ 4000 m 480 V 0.93 x Iu

4000 < h ≤ 5000 m 420 V 0.90 x Iu

Motor Protective Circuit Breakers MPW - Technical Data

ALTITUDE - CORRECTION FACTOR

The MPW motor protective circuit breakers do not undergo

any change to their specified performance when applied at

an altitude of up to 2000 meters above sea level.

However, as the altitude increases, the atmospheric

properties vary in terms of dielectric rigidness and pressure.

Therefore, current and voltage correction factors must be

applied for altitudes exceeding 2000 meters, as shown in the

following table.

Reference code MPW16 MPW16i MPW12_S MPW12i_S

Maximum rated current imax

(iu) 16 A 16 A 12 A 12 A

Number of poles 3 3 3 3

Instantaneous short-circuit 13 x Iemax. 13 x I

emax. 13 x I

emax. 13 x I

emax.

Rated operational voltage Ue

690 V 1) 690 V 1) 690 V 1) 690 V 1)

Rated operational frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz

Insulation voltage Ui

690 V 690 V 690 V 690 V

Rated impulse withstand voltage Uimp

6 kV 6 kV 6 kV 6 kV

Utilization category IEC 60 947-2 (circuit breaker) A A A A

IEC 60 947-4-1 (motor starter) AC-3 AC-3 AC-3 AC-3

Tripping test Yes Yes Yes Yes

Overload protection Yes No Yes No

Phase failure sensitivity Yes No Yes No

Tripping indication Yes Yes Yes Yes

Tripping class 10 - 10 -

Maximum operation per hour Operations/hour 15 15 15 15

Altitude (m) 2000 2000 2000 2000

Degree of protection IP20 IP20 IP20 IP20

Mechanical life span Number of operations 100,000 100,000 100,000 100,000

Electrical life span Number of operations 100,000 100,000 100,000 100,000

Ambient temperatures allowed

Transport and storage -50...+80 °C -50...+80 °C -50...+80 °C -50...+80 °C

Operation 1) -20...+70 °C -20...+70 °C -20...+70 °C -20...+70 °C

Temperature compensation -20...+60 °C - -20...+60 °C -

Resistance to impact (g) 15 15 15 15

Standards

IEC/EN 60 947-1. DIN VDE 0660 (part 100) Yes Yes Yes Yes

IEC/EN 60 947-2. DIN VDE 0660 (part 101) Yes Yes Yes Yes

IEC/EN 60 947-4-1. DIN VDE 0660 (part 102) Yes Yes Yes Yes

Terminal capacity

Type of terminal Flat Flat - -

Tightening torqueN.m 1.2...1.7 1.2...1.7 - -

lb.in 11...16 11...16 - -

Type of screws Philips (Nº2) Philips (Nº2) - -

Dimensions

Width (mm) 45 45 45 45

Height (mm) 90 90 100 100

Depth (mm) 77 77 77 77

Note: 1) Reduce current for temperatures exceeding +60 °C (87% to 70 °C).

Page 73: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

142 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 143

The MPW16, MPW25 and MPW65 motor protective circuit

breakers can also be used for operating continuous current

loads. For such operation it is necessary to connect 2 or 3

poles in series.

See recommended circuits and their voltage limits in the

table on the right.

Time constant t = 5ms

Short-circuit breaking capacity Icu = 10 kA for all

configurations.

Circuits Max. V dc Notes

150 V dc

System not

grounded

2 pole series connected

300 V dc

System

grounded

2 pole series connected

450 V dc

System

grounded

3 pole series connected

DC OPERATION

Reference code MPW25 MPW25i MPW25t MPW65 MPW65i MPW100

Maximum rated current Imax

(Iu) 32 A 32 A 32 A 65 A 65 A 100 A

Number of poles 3 3 3 3 3 3

Instantaneous short-circuit 13 x Iemax. 13 x I

emax. 19 x I

emax. 13 x I

emax. 13 x I

emax. 13 x I

emax.

Rated operational voltage Ue

690 V 1) 690 V 1) 690 V 1) 690 V 690 V 690 V

Rated operational frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz

Insulation voltage Ui

690 V 690 V 690 V 690 V 690 V 1000 V

Rated impulse withstand voltage Uimp

6 kV 6 kV 6 kV 6 kV 6 kV 8 kV

Utilization categoryIEC 60 947-2 (circuit breaker) A A A A A A

IEC 60 947-4-1 (motor starter) AC-3 AC-3 AC-3 AC-3 AC-3 AC-3

Tripping test Yes Yes Yes Yes Yes Yes

Overload protection Yes No Yes Yes No Yes

Phase failure sensitivity Yes No Yes Yes No Yes

Tripping indication Yes Yes Yes Yes Yes Yes

Tripping class 10 - Yes 10 - 10

Maximum operating

frequencyOperations/hour 15 15 15 15 15 25

Altitude (m) 2000 2000 2000 2000 2000 2000

Degree of protection IP20 IP20 IP20 IP20 IP20 IP20

Mechanical life span Number of operations 100,000 100,000 100,000 50,000 50,000 50,000

Electrical life span Number of operations 100,000 100,000 100,000 25,000 25,000 25,000

Ambient temperatures allowed

Transport and storage -50...+80 °C -50...+80 °C -50...+80 °C -50...+80 °C -50...+80 °C -50...+80 °C

Operation 1) -20...+70 °C -20...+70 °C -20...+70 °C -20...+70 °C -20...+70 °C -20...+60 °C

Temperature compensation -20...+60 °C - - -20...+60 °C - -20...+60 °C

Resistance to impact (g) 15 15 15 15 15 25

Standards

IEC/EN 60 947-1, DIN VDE 0660 (part 100) Yes Yes Yes Yes Yes Yes

IEC/EN 60 947-2, DIN VDE 0660 (part 101) Yes Yes Yes Yes Yes Yes

IEC/EN 60 947-4-1, DIN VDE 0660 (part 102) Yes Yes Yes Yes Yes Yes

Terminal capacity

Type of terminal Flat Flat Flat Box Box Box

Tightening torqueN.m 2...2.5 2...2.5 2...2.5 4...6 4...6 4...6

lb.in 18...22 18...22 18...22 35...55 35...55 35...53

Type of screws Philips (Nº2) Philips (Nº2) Philips (Nº2) Allen (4 mm) Allen (4 mm) Allen (4 mm)

Dimensions

Width (mm) 45 45 45 54 54 70

Height (mm) 97 97 97 125 125 165

Depth (mm) 98 98 98 157 157 171

Note: 1) Reduce current for temperatures exceeding +60 °C (87% to 70 °C).

Accessories for Motor Protective Circuit-Breaker

DESCRIPTION TERMINAL TYPE CIRCUIT-BREAKER TYPE STOCK CODEPRICE EACH

(ZAR)

Front mountable auxiliary contact block

(1NO+1NC)

Spring MPW16_S ACBF-11S 11419002 93,00

Screw MPW16, MPW25, MPW65 ACBF-11 10353835 85,00

Screw MPW100 ACBF-11 MPW100 10047296 180,00

Side mountable auxiliary contact block

(1NO+1NC)

Spring MPW16_S ACBS-11S 11419005 99,00

Screw MPW16, MPW25, MPW65 ACBS-11 10409821 90,00

Screw MPW100 ACBS 11-MPW100 10047297 272,00

Side mountable auxiliary contact block

(2NO)

Spring MPW16_S ACBS-20S 11419007 99,00

Screw MPW16, MPW25, MPW65 ACBS-20 10045322 90,00

Screw MPW100 ACBS 20-MPW100 10076555 272,00

Side mountable auxiliary

contact block (2NC)

Spring MPW16_S ACBS-02S 11419006 99,00

Screw MPW16, MPW25, MPW65 ACBS-02 10076989 90,00

Screw MPW100 ACBS-02-MPW100 10076556 272,00

Trip signalling block

Screw MPW25, MPW65 TSB 10561996 298,00

Screw MPW100 TSB AT-11 MPW100 10047298 304,00

Screw MPW100 TSB SC-11 MPW100 10076559 304,00

Cur. limiter Screw MPW16, MPW25 CLTMPW25 10583764 471,00

45 mm busbars adapter

- MPW16, MPW25 BBS45-2 10045352 155,00

- MPW16, MPW25 BBS45-3 10045351 177,00

- MPW16, MPW25 BBS45-4 10045350 177,00

- MPW16, MPW25 BBS45-5 10045349 236,00

54 mm busbars adapter

- MPW16, MPW25 BBS54-2 10409844 162,00

- MPW16, MPW25 BBS54-3 10409845 186,00

- MPW16, MPW25 BBS54-4 10409846 195,00

- MPW16, MPW25 BBS54-5 10409847 284,00

Feeder term. - MPW16, MPW25 FTBBS 10409848 118,00

Starter type “E” - MPW16, MPW25 LST25 10047102 298,00

Starter type “E” - MPW65 LST65 11112690 466,00

Starter type “E” - MPW100 IB MPW100 10213096 103,00

BLOCKS / BUSBARS ADAPTERS / LINKS

Page 74: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

144 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 145

Accessories for Motor Protective Circuit-Breaker

UNDERVOLTAGE RELEASE - SCREW TYPE

REMOTE SHUNT RELEASE - SCREW TYPE

RATED VOLTAGE (V) CIRCUIT-BREAKER TYPE STOCK CODEPRICE EACH

(ZAR)

110 V 50 Hz / 120 V 60 Hz

MPW16

MPW25

MPW65

URMP V18 10657748 274,00

110-115 V 50 Hz / 127 V 60 Hz URMP V19 10186280 261,00

180 V 50 Hz / 208 V 60 Hz URMP V23 10212439 261,00

190 V 50 Hz / 220 V 60 Hz URMP V26 10186281 274,00

220 V 50 Hz / 255 V 60 Hz URMP V32 10186309 274,00

208 V 50 Hz / 240 V 60 Hz URMP V30 10212440 261,00

230-240 V 50 Hz / 277 V 60 Hz URMP V37 10186285 274,00

325 V 50 Hz / 380 V 60 Hz URMP V41 10211171 274,00

380 V 50 Hz / 440 V 60 Hz URMP V42 10657758 274,00

400-415 V 50 Hz / 480 V 60 Hz URMP V47 10657829 274,00

24 V 50/60 Hz URMP D02 10666333 274,00

220 V 50/60 Hz URMP D23 10657830 261,00

110 V 50 Hz / 120 V 60 Hz

MPW100

URMP V18 MPW100 10186875 473,00

220-230 V 50 Hz / 240-260 V 60 Hz URMP V33 MPW100 10186876 473,00

380-400 V 50 Hz / 440-460 V 60 Hz URMP V43 MPW100 10186877 473,00

RATED VOLTAGE (V) CIRCUIT-BREAKER TYPE STOCK CODEPRICE EACH

(ZAR)

20-24 V 50/60 Hz

MPW16

MPW25

MPW65

SRMP D51 10186283 274,00

40-48 V 50/60 Hz SRMP D54 10211173 274,00

100-127 V 50/60 Hz SRMP D59 10186284 274,00

200-240 V 50/60 Hz SRMP D65 10186275 274,00

365-440 V 50/60 Hz SRMP D69 10211174 274,00

110 V 50 Hz / 120 V 60 Hz

MPW100

SRMP V18 MPW100 10186872 473,00

220-230 V 50 Hz / 240-260 V 60 Hz SRMP V33 MPW100 10186873 473,00

380-400 V 50 Hz / 440-460 V 60 Hz SRMP V43 MPW100 10186874 473,00

Accessories for Motor Protective Circuit-Breaker

DOOR-COUPLING ROTARY HANDLE

DESCRIPTION CIRCUIT-BREAKER TYPE HANDLE COLOUR STOCK CODEPRICE EACH

(ZAR)

Door-coupling

rotary handle

MPW25

RMMP-130 Black 10185921 339,00

RMMP-130E Red 10185923 381,00

RMMP-330 Black 10185922 396,00

RMMP-330E Red 10185924 439,00

MRX-130 Black 11051796 366,00

MRX-130E Red 10857691 412,00

MRX-330 Black 11051797 428,00

MRX-330E Red 10857692 474,00

MPW65

RMMP65-130 Black 11068497 339,00

RMMP65-130E Red 11068518 381,00

RMMP65-330 Black 11068519 396,00

RMMP65-330E Red 11068520 439,00

MRX65-130 Black 11068521 366,00

MRX65-130E Red 11068522 412,00

MRX65-330 Black 11068523 428,00

MRX65-330E Red 11068525 474,00

MPW100

MR MPW100-115 Gray 10609710 473,00

MR MPW100-315 Gray 10609711 473,00

MRX100-130 Black 11152799 542,00

MRX100-130E Red 11152800 610,00

Page 75: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

146 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 147

Accessories for Motor Protective Circuit-Breaker

INSULATED ENCLOSURE

Note : 1) Upon Request.

Allows the installation of undervoltage or remote shunt release (SRMP or URMP).

DESCRIPTION CIRCUIT-BREAKER TYPE PROT. DEGREE HANDLE COLOUR STOCK CODEPRICE EACH

(ZAR)

No lugs

(M25) - knockout

MPW16MPE41 IP41 - 11146211 124,00

MPE66 IP66 - 11065621 172,00

MPW25MPE55 IP55 Black 10211804 149,00

MPE55-E IP55 Red 10211805 154,00

With ground terminals

(M25) - knockout

MPW16MPE41G IP41 - 10831702 132,00

MPE66G IP66 - 10831703 180,00

MPW25MPE55G IP55 Black 10649171 158,00

MPE55G-E IP55 Red 10186289 162,00

With ground and neutral lugs

(M25) - knockout

MPW16MPE41GN IP41 - 11146214 140,00

MPE66GN IP66 - 11065622 188,00

MPW25MPE55GN IP55 Black 10211953 165,00

MPE55GN-E IP55 Red 10211954 169,00

No lugs

(PG16) - knockout

MPW16PE41 IP41 - 10831536 124,00

PE66 IP66 - 10831535 172,00

MPW25PE55 IP55 Black 10185915 149,00

PE55-E IP55 Red 10185916 154,00

With ground terminals

(PG16) - knockout

MPW16PE41G IP41 - 10831606 132,00

PE66G IP66 - 10831643 180,00

MPW25PE55G IP55 Black 10185917 158,00

PE55G-E IP55 Red 10185918 162,00

With ground and neutral lugs

(PG16) - knockout

MPW16PE41GN IP41 - 10831607 140,00

PE66GN IP66 - 10831700 188,00

MPW25PE55GN IP55 Black 10185919 165,00

PE55GN-E IP55 Red 10185920 169,00

Increases protection degree

of MPE41 to IP66MPW16 KIT66PE IP66 - 10853867 49,00

E-STOP - twist to releaseMPW16

FESTPE - Red 11659180 155,00

E-STOP - key to release FESYPE - Red 11659178 Upon request

INSULATED ENCLOSURE SIZE “L” - IP55

DESCRIPTION CIRCUIT-BREAKER TYPE HANDLE COLOUR STOCK CODEPRICE EACH

(ZAR)

No lugs (M25) - knockout MPW25MLPE55 Black 10212325 232,00

MLPE55-E Red 10212326 239,00

With ground terminals

(M25) - knockoutMPW25

MLPE55G Black 10211362 249,00

MLPE55G-E Red 10211363 256,00

With ground and neutral lugs

(M25) - knockoutMPW25

MLPE55GN Black 10211955 256,00

MLPE55GN-E Red 10211956 263,00

FRONTAL PLATE

DESCRIPTION CIRCUIT-BREAKER TYPE HANDLE COLOUR STOCK

CODE

PRICE EACH

(ZAR)

IP55MPW25

FME55 Black 10186425 487,00

IP55 FME55E Red 10186426 502,00

Accessories for Motor Protective Circuit-Breaker

PUSH-IN-LUGS / CIRCUIT-BREAKER - CONTACTOR LINK MODULE / SCALE COVER

DESCRIPTION CIRCUIT-BREAKER TYPE STOCK CODEPRICE EACH

(ZAR)

Push-in-lugs 2) MPW16, MPW25, MPW65 PLMP 10185925 3,00

Link module CWC07...16 MPW16 ECCMP-C016 10867179 71,00

Link module CWC07...16 MPW25 ECCMP-C0 10047217 71,00

Link module CWC025 MPW25 ECCMP-C025 10689937 71,00

Link module WM9...25 MPW25 ECCMP-25 10409822 71,00

Link module CWM32 MPW25 ECCMP-32 10075736 71,00

Scale cover MPW16, MPW25, MPW65 SCMP 10186290 9,00

Protection cover for BBS - CSD 10073627 58,00

Mounting adapter for direct-on-line starter MPW16, MPW25 MA45DOL MPW 10073629 246,00

Mounting adapter for reversing starters MPW16, MPW25 MA90RVS MPW 10073628 312,00

Mounting adapter for star-delta starters MPW16, MPW25 MA90SDS MPW 10073630 520,00

Connector PCB main contacts MPW16 CIC16 11647168 Upon request

Connector PCB - mains and aux. cont. MPW16 CIC16A 11647117 Upon request

Note : 1) Upon Request.

2) Quantity per packing: 2 units.

INDICATOR LIGHT

RATED VOLTAGE (V) TYPE COLOUR STOCK CODEPRICE EACH

(ZAR)

24 Vac

PL24-E26 Red 10046226 109,00

PL24G-E26 Green 10046228 109,00

PL24W-E26 White 10046230 109,00

110-130 Vac

PL130-D61 Red 10045246 109,00

PL130G-D61 Green 10046229 109,00

PL130W-D61 White 10046231 109,00

210-230 Vac

PL230-D78 Red 10045247 109,00

PL230G-D78 Green 10186288 109,00

PL230W-D78 White 10211181 109,00

400-560 Vac

PL560D-D79 Red 10046227 127,00

PL560G-D79 Green 10211180 127,00

PL560W-D79 White 10046232 127,00

Page 76: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

148 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 149

Rated operational power

400-415 V

(kW)

Rated operational

current

Ie

(A)

Setting overload

release

Ir

(A)

Reference code

Motor protective

Circuit breaker

Reference code contactors

Actualing voltage

(230 V 50/60 Hz)

0.06 0.21 0.16...0.25 MPW25-3-C025 CWM9-10-30D24 (230 V 50/60 Hz)

0.09 0.31 0.25...0.4 MPW25-3-D004 CWM9-10-30D24 (230 V 50/60 Hz)

0.12 0.41 0.4...0.63 MPW25-3-C063 CWM9-10-30D24 (230 V 50/60 Hz)

0.18 0.6 0.4...0.63 MPW25-3-C063 CWM9-10-30D24 (230 V 50/60 Hz)

0.25 0.8 0.63...1.0 MPW25-3-U001 CWM9-10-30D24 (230 V 50/60 Hz)

0.37 1.1 1.0...1.6 MPW25-3-D016 CWM9-10-30D24 (230 V 50/60 Hz)

0.55 1.5 1.0...1.6 MPW25-3-D016 CWM9-10-30D24 (230 V 50/60 Hz)

0.75 1.9 1.6...2.5 MPW25-3-D025 CWM9-10-30D24 (230 V 50/60 Hz)

1.1 2.6 2.5...4.0 MPW25-3-U004 CWM9-10-30D24 (230 V 50/60 Hz)

1.5 3.6 2.5...4.0 MPW25-3-U004 CWM9-10-30D24 (230 V 50/60 Hz)

2.2 5 4.0...6.3 MPW25-3-D063 CWM9-10-30D24 (230 V 50/60 Hz)

3.0 6.6 6.3...10 MPW25-3-U010 CWM9-10-30D24 (230 V 50/60 Hz)

4.0 8.5 6.3...10 MPW25-3-U010 CWM9-10-30D24 (230 V 50/60 Hz)

5.5 11.3 10...16 MPW25-3-U016 CWM12-10-30D24 (230 V 50/60 Hz)

7.5 15.2 10...16 MPW25-3-U016 CWM18-10-30D24 (230 V 50/60 Hz)

9.2 17.8 16...20 MPW25-3-U020 CWM18-10-30D24 (230 V 50/60 Hz)

11 21.7 20...25 MPW25-3-U025 CWM25-10-30D24 (230 V 50/60 Hz)

15 29.3 25...32 MPW25-3-U032 CWM32-10-30D24 (230 V 50/60 Hz)

M

3~

I

TYPE “1” COORDINATION - RATED CONDITIONAL SHORT-CIRCUIT CURRENT IQ = 50 KA/400-415 V

Motor Protective Circuit Breakers MPW25 - Coordination Tables

DIRECT-ON-LINE STARTERS

Direct-on-line starters consist of a motor protective circuit breaker MPW25 and CWM contactor, which are already electrically

and mechanically connected via the block module ECCMP.

Ordering example: the type can be found in the “Rated operational power” column alongside the selected rating 2.2 kW,

desired type: MPW25-3-D063 + CWM9-10-30D24 (230 V 50/60 Hz).

Rated operational

power

400-415 V

(kW)

Rated operational

current

Ie

(A)

Operational

instalaneous current

I

(A)

Reference code

Motor protective

Circuit breaker

Reference code contactors

Actualing voltage

(230 V 50/60 Hz)

0.06 0.21 0.25 MPW25i-3-C025 CWM9-10-30D24 (230 V 50/60 Hz)

0.09 0.31 0.4 MPW25i-3-D004 CWM9-10-30D24 (230 V 50/60 Hz)

0.12 0.41 0.63 MPW25i-3-C063 CWM9-10-30D24 (230 V 50/60 Hz)

0.18 0.6 0.63 MPW25i-3-C063 CWM9-10-30D24 (230 V 50/60 Hz)

0.25 0.8 1.0 MPW25i-3-U001 CWM9-10-30D24 (230 V 50/60 Hz)

0.37 1.1 1.6 MPW25i-3-D016 CWM9-10-30D24 (230 V 50/60 Hz)

0.55 1.5 1.6 MPW25i-3-D016 CWM9-10-30D24 (230 V 50/60 Hz)

0.75 1.9 2.5 MPW25i-3-D025 CWM9-10-30D24 (230 V 50/60 Hz)

1.1 2.6 4.0 MPW25i-3-U004 CWM9-10-30D24 (230 V 50/60 Hz)

1.5 3.6 4.0 MPW25i-3-U004 CWM9-10-30D24 (230 V 50/60 Hz)

2.2 5 6.3 MPW25i-3-D063 CWM9-10-30D24 (230 V 50/60 Hz)

3.0 6.6 10 MPW25i-3-U010 CWM9-10-30D24 (230 V 50/60 Hz)

4.0 8.5 10 MPW25i-3-U010 CWM9-10-30D24 (230 V 50/60 Hz)

5.5 11.3 16 MPW25i-3-U016 CWM12-10-30D24 (230 V 50/60 Hz)

7.5 15.2 16 MPW25i-3-U016 CWM18-10-30D24 (230 V 50/60 Hz)

9.2 17.8 20 MPW25i-3-U020 CWM18-10-30D24 (230 V 50/60 Hz)

11 21.7 25 MPW25i-3-U025 CWM25-10-30D24 (230 V 50/60 Hz)

15 29.3 32 MPW25i-3-U032 CWM32-10-30D24 (230 V 50/60 Hz)

DIRECT-ON-LINE STARTERS

Direct-on-line starters consist of a motor protective circuit breaker MPW25i and CWM contactor, which are already electrically

and mechanically connected via the block module ECCMP.

Ordering example: the type can be found in the “Rated operational power” column alongside the selected rating 2.2 kW,

desired type: MPW25i-3-D063 + CWM9-10-30D24 (230 V 50/60 Hz).

TYPE “1” COORDINATION - RATED CONDITIONAL SHORT-CIRCUIT CURRENT IQ = 50 KA/400-415 V

M

3~

I

Page 77: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

150 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 151

Rated operational

power

400-415 V

(kW)

Rated operational

current

Ie

(A)

Setting overload

release

Ir

(A)

Reference code

Motor protective

Circuit breaker

Iq = 50 kA Iq = 65 kA

Reference code contactors

Actualing voltage

(230 V 50/60 Hz)

Reference code contactors

Actualing voltage

(230 V 50/60 Hz)

0.06 0.21 0.16...0.25 MPW25-3-C025 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz)

0.09 0.31 0.25...0.4 MPW25-3-D004 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz)

0.12 0.41 0.4...0.63 MPW25-3-C063 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz)

0.18 0.6 0.4...0.63 MPW25-3-C063 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz)

0.25 0.8 0.63...1.0 MPW25-3-U001 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz)

0.37 1.1 1.0...1.6 MPW25-3-D016 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz)

0.55 1.5 1.0...1.6 MPW25-3-D016 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz)

0.75 1.9 1.6...2.5 MPW25-3-D025 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz)

1.1 2.6 2.5...4.0 MPW25-3-U004 CWM9-10-30D24 (230 V 50/60 Hz) CWM25-10-30D24 (230 V 50/60 Hz)

1.5 3.6 2.5...4.0 MPW25-3-U004 CWM9-10-30D24 (230 V 50/60 Hz) CWM25-10-30D24 (230 V 50/60 Hz)

2.2 5 4.0...6.3 MPW25-3-D063 CWM9-10-30D24 (230 V 50/60 Hz) CWM25-10-30D24 (230 V 50/60 Hz)

3.0 6.6 6.3...10 MPW25-3-U010 CWM9-10-30D24 (230 V 50/60 Hz) CWM32-10-30D24 (230 V 50/60 Hz)

4.0 8.5 6.3...10 MPW25-3-U010 CWM9-10-30D24 (230 V 50/60 Hz) CWM32-10-30D24 (230 V 50/60 Hz)

5.5 11.3 10...16 MPW25-3-U016 CWM12-10-30D24 (230 V 50/60 Hz) CWM32-10-30D24 (230 V 50/60 Hz)

7.5 15.2 10...16 MPW25-3-U016 CWM18-10-30D24 (230 V 50/60 Hz) CWM32-10-30D24 (230 V 50/60 Hz)

9.2 17.8 16...20 MPW25-3-U020 CWM18-10-30D24 (230 V 50/60 Hz) CWM32-10-30D24 (230 V 50/60 Hz)

11 21.7 20...25 MPW25-3-U025 CWM25-10-30D24 (230 V 50/60 Hz) CWM40-10-30D24 (230 V 50/60 Hz)

15 29.3 25...32 MPW25-3-U032 CWM50-10-30D24 (230 V 50/60 Hz) CWM50-10-30D24 (230 V 50/60 Hz)

TYPE “2” COORDINATION - RATED CONDITIONAL SHORT-CIRCUIT CURRENT IQ = 50/65 KA IN 400-415 V

DIRECT-ON-LINE STARTERS

Direct-on-line starters consists of a motor protective circuit breaker MPW25 and CWM contactor, which are already electrically

and mechanically connected via the block module ECCMP up to 32 A.

Ordering example: the type can be found in the “Rated operational power” column alongside the selected rating 2.2 kW,

desired type: MPW25-3-D063 + CWM9-10-30D24 (230 V 50/60 Hz).

M

3~

I

Rated operational

power

400-415 V

(kW)

Rated operational

current

Ie

(A)

Operational

instalaneous current

I

(A)

Reference code

Motor protective

Circuit breaker

Iq = 50 kA Iq = 65 kA

Reference code contactors

Actualing voltage

(230 V 50/60 Hz)

Reference code contactors

Actualing voltage

(230 V 50/60 Hz)

0.06 0.21 0.25 MPW25i-3-C025 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz)

0.09 0.31 0.4 MPW25i-3-D004 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz)

0.12 0.41 0.63 MPW25i-3-C063 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz)

0.18 0.6 0.63 MPW25i-3-C063 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz)

0.25 0.8 1.0 MPW25i-3-U001 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz)

0.37 1.1 1.6 MPW25i-3-D016 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz)

0.55 1.5 1.6 MPW25i-3-D016 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz)

0.75 1.9 2.5 MPW25i-3-D025 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz)

1.1 2.6 4.0 MPW25i-3-U004 CWM9-10-30D24 (230 V 50/60 Hz) CWM25-10-30D24 (230 V 50/60 Hz)

1.5 3.6 4.0 MPW25i-3-U004 CWM9-10-30D24 (230 V 50/60 Hz) CWM25-10-30D24 (230 V 50/60 Hz)

2.2 5 6.3 MPW25i-3-D063 CWM9-10-30D24 (230 V 50/60 Hz) CWM25-10-30D24 (230 V 50/60 Hz)

3.0 6.6 10 MPW25i-3-U010 CWM9-10-30D24 (230 V 50/60 Hz) CWM32-10-30D24 (230 V 50/60 Hz)

4.0 8.5 10 MPW25i-3-U010 CWM9-10-30D24 (230 V 50/60 Hz) CWM32-10-30D24 (230 V 50/60 Hz)

5.5 11.3 16 MPW25i-3-U016 CWM12-10-30D24 (230 V 50/60 Hz) CWM32-10-30D24 (230 V 50/60 Hz)

7.5 15.2 16 MPW25i-3-U016 CWM18-10-30D24 (230 V 50/60 Hz) CWM32-10-30D24 (230 V 50/60 Hz)

9.2 17.8 20 MPW25i-3-U020 CWM18-10-30D24 (230 V 50/60 Hz) CWM32-10-30D24 (230 V 50/60 Hz)

11 21.7 25 MPW25i-3-U025 CWM25-10-30D24 (230 V 50/60 Hz) CWM40-10-30D24 (230 V 50/60 Hz)

15 28.93 32 MPW25i-3-U032 CWM50-10-30D24 (230 V 50/60 Hz) CWM50-10-30D24 (230 V 50/60 Hz)

DIRECT-ON-LINE STARTERS

Direct-on-line starters consists of a motor protective circuit breaker MPW25i and CWM contactor, which are already electrically

and mechanically connected via the block module ECCMP up to 32 A.

Ordering example: the type can be found in the “Rated operational power” column alongside the selected rating 2.2 kW,

desired type: MPW25i-3-D063 + CWM9-10-30D24 (230 V 50/60 Hz).

TYPE “2” COORDINATION - RATED CONDITIONAL SHORT-CIRCUIT CURRENT IQ = 50/65 KA IN 400-415 V

M

3~

I

Page 78: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

152 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 153

Rated operational

power

400-415 V

(kW)

Rated operational

current

Ie

(A)

Setting overload

release

Ir

(A)

Reference code

Motor protective

Circuit breaker

Iq = 50 kA Iq = 65 kA

Reference code contactors

Actualing voltage

(230 V 50/60 Hz)

Reference code contactors

Actualing voltage

(230 V 50/60 Hz)

0.06 0.21 0.16...0.25 MPW25-3-C025 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz)

0.09 0.31 0.25...0.4 MPW25-3-D004 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz)

0.12 0.41 0.4...0.63 MPW25-3-C063 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz)

0.18 0.6 0.4...0.63 MPW25-3-C063 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz)

0.25 0.8 0.63...1.0 MPW25-3-U001 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz)

0.37 1.1 1.0...1.6 MPW25-3-D016 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz)

0.55 1.5 1.0...1.6 MPW25-3-D016 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz)

0.75 1.9 1.6...2.5 MPW25-3-D025 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz)

1.1 2.6 2.5...4.0 MPW25-3-U004 CWM9-10-30D24 (230 V 50/60 Hz) CWM25-10-30D24 (230 V 50/60 Hz)

1.5 3.6 2.5...4.0 MPW25-3-U004 CWM9-10-30D24 (230 V 50/60 Hz) CWM25-10-30D24 (230 V 50/60 Hz)

2.2 5 4.0...6.3 MPW25-3-D063 CWM9-10-30D24 (230 V 50/60 Hz) CWM25-10-30D24 (230 V 50/60 Hz)

3.0 6.6 6.3...10 MPW25-3-U010 CWM9-10-30D24 (230 V 50/60 Hz) CWM32-10-30D24 (230 V 50/60 Hz)

4.0 8.5 6.3...10 MPW25-3-U010 CWM9-10-30D24 (230 V 50/60 Hz) CWM32-10-30D24 (230 V 50/60 Hz)

5.5 11.3 10...16 MPW25-3-U016 CWM12-10-30D24 (230 V 50/60 Hz) CWM32-10-30D24 (230 V 50/60 Hz)

7.5 15.2 10...16 MPW25-3-U016 CWM18-10-30D24 (230 V 50/60 Hz) CWM32-10-30D24 (230 V 50/60 Hz)

9.2 17.8 16...20 MPW25-3-U020 CWM18-10-30D24 (230 V 50/60 Hz) CWM32-10-30D24 (230 V 50/60 Hz)

11 21.7 20...25 MPW25-3-U025 CWM25-10-30D24 (230 V 50/60 Hz) CWM40-10-30D24 (230 V 50/60 Hz)

15 29.3 25...32 MPW25-3-U032 CWM50-10-30D24 (230 V 50/60 Hz) CWM50-10-30D24 (230 V 50/60 Hz)

TYPE “2” COORDINATION - RATED CONDITIONAL SHORT-CIRCUIT CURRENT IQ = 50/65 KA IN 400-415 V

DIRECT-ON-LINE STARTERS

Direct-on-line starters consists of a motor protective circuit breaker MPW25 and CWM contactor, which are already electrically

and mechanically connected via the block module ECCMP up to 32 A.

Ordering example: the type can be found in the “Rated operational power” column alongside the selected rating 2.2 kW,

desired type: MPW25-3-D063 + CWM9-10-30D24 (230 V 50/60 Hz).

M

3~

I

Rated operational

power

400-415 V

(kW)

Rated operational

current

Ie

(A)

Operational

instalaneous current

I

(A)

Reference code

Motor protective

Circuit breaker

Iq = 50 kA Iq = 65 kA

Reference code contactors

Actualing voltage

(230 V 50/60 Hz)

Reference code contactors

Actualing voltage

(230 V 50/60 Hz)

0.06 0.21 0.25 MPW25i-3-C025 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz)

0.09 0.31 0.4 MPW25i-3-D004 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz)

0.12 0.41 0.63 MPW25i-3-C063 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz)

0.18 0.6 0.63 MPW25i-3-C063 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz)

0.25 0.8 1.0 MPW25i-3-U001 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz)

0.37 1.1 1.6 MPW25i-3-D016 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz)

0.55 1.5 1.6 MPW25i-3-D016 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz)

0.75 1.9 2.5 MPW25i-3-D025 CWM9-10-30D24 (230 V 50/60 Hz) CWM9-10-30D24 (230 V 50/60 Hz)

1.1 2.6 4.0 MPW25i-3-U004 CWM9-10-30D24 (230 V 50/60 Hz) CWM25-10-30D24 (230 V 50/60 Hz)

1.5 3.6 4.0 MPW25i-3-U004 CWM9-10-30D24 (230 V 50/60 Hz) CWM25-10-30D24 (230 V 50/60 Hz)

2.2 5 6.3 MPW25i-3-D063 CWM9-10-30D24 (230 V 50/60 Hz) CWM25-10-30D24 (230 V 50/60 Hz)

3.0 6.6 10 MPW25i-3-U010 CWM9-10-30D24 (230 V 50/60 Hz) CWM32-10-30D24 (230 V 50/60 Hz)

4.0 8.5 10 MPW25i-3-U010 CWM9-10-30D24 (230 V 50/60 Hz) CWM32-10-30D24 (230 V 50/60 Hz)

5.5 11.3 16 MPW25i-3-U016 CWM12-10-30D24 (230 V 50/60 Hz) CWM32-10-30D24 (230 V 50/60 Hz)

7.5 15.2 16 MPW25i-3-U016 CWM18-10-30D24 (230 V 50/60 Hz) CWM32-10-30D24 (230 V 50/60 Hz)

9.2 17.8 20 MPW25i-3-U020 CWM18-10-30D24 (230 V 50/60 Hz) CWM32-10-30D24 (230 V 50/60 Hz)

11 21.7 25 MPW25i-3-U025 CWM25-10-30D24 (230 V 50/60 Hz) CWM40-10-30D24 (230 V 50/60 Hz)

15 28.93 32 MPW25i-3-U032 CWM50-10-30D24 (230 V 50/60 Hz) CWM50-10-30D24 (230 V 50/60 Hz)

DIRECT-ON-LINE STARTERS

Direct-on-line starters consists of a motor protective circuit breaker MPW25i and CWM contactor, which are already electrically

and mechanically connected via the block module ECCMP up to 32 A.

Ordering example: the type can be found in the “Rated operational power” column alongside the selected rating 2.2 kW,

desired type: MPW25i-3-D063 + CWM9-10-30D24 (230 V 50/60 Hz).

TYPE “2” COORDINATION - RATED CONDITIONAL SHORT-CIRCUIT CURRENT IQ = 50/65 KA IN 400-415 V

M

3~

I

Page 79: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

154 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 155

RATED POWER

AC-3 / 220 V

50 Hz

kW/hp

RATED POWER

AC-3 / 400 V

50 Hz

kW/hp

RATED POWER

AC-3 / 500 V

50 Hz

kW/hp

RANGE OF

OVERLOAD

RELAY (A)

CONTACTOR TYPE

STOCK CODE

CONTROL

VOLTAGE 230 VAC

STOCK CODE

CONTROL

VOLTAGE 400 VAC

STOCK CODE &

CONTROL

VOLTAGE 500 VAC

PRICE EACH

(ZAR)

0,06...1.5 0,09...3 (1,28...8) CW07 DLW-7D34P65 10076575 10076577 N/A 465,00

Size 04 (50/60Hz)

2,2 4 4 (7 ... 10) CWM9 DLW-9P65 10076576 10076578 12207056 564,00

3 5,5 5,5 (8 ... 12,5) CWM12 DLW-12P65 10076959 11076778 12207057 582,00

4 7,5 ... 9,2 7,5 ... 9,2 (11 ... 17) CWM18 DLW-18P65 11076781 11076780 12207088 644,00

5,5 11 11 (15 ... 23) CWM25 DLW-25P65 11142614 11142613 12378628 764,00

7,5 - (22 ... 32) - -

SIZE 06 (50/60Hz)

15 15 (22 ... 32) CWM32 DLW-32P65 11076783 11076782 12384274 1193,00

11 18,5 18,5 (25 ... 40) CWM40 DLW-40P65 11076829 11076785 12384275 1746,00

RATED POWER AC-3 / 220 V

50 Hz

kW/hp

RANGE OF

OVERLOAD

RELAY (A)

CONTACTOR TYPE STOCK CODE CONTROL VOLTAGE 230 VAC PRICE EACH

(ZAR)

SIZE 02 (50/60Hz)

0,25 (1,8 ... 2,8) CW07 DLW-7D24P65-RM06 10868043 887,00

0,37 (2,8 ... 4) CW07 DLW-7D24P65-RM07 10868040 887,00

0,55...0,75 (4 ...6,3) CW07 DLW-7D24P65-RM08 10186427 887,00

1,1 (6,3 ...8) CW07 DLW-7D24P65-RM09 10868042 887,00

SIZE 04 (50/60Hz)

1,5 (8...12.5) CWM12 DLW-12D24P65-RM30 10186453 1146,00

2,2 (10...15) CWM18 DLW-18D24P65-RM31 10873957 1230,00

3 (15...23) CWM18 DLW-18D24P65-RM33 10186628 1230,00

3,7 (15...23) CWM25 DLW-25D24P65-RM33 10186454 1417,00

SIZE 06 (50/60Hz)

7,5 (25...40) CWM32 DLW-32D24P65-RM30 10073255 2669,00

11 (32...50) CWM40 DLW-40D24P65-RM31 10073256 3228,00

Different control voltage are available under request.

Enclosed Direct-On-Line Starter - DLW (IP65 / 50 Hz)

ENCLOSED DIRECT-ON-LINE STARTER THREE-PHASE - DLW

INCLUDING OVERLOAD RELAY

RATED POWER

AC-3 / 50 Hz

kW

RATED POWER

AC-3 / 50 Hz

kW

RATED POWER

AC-3 / 50 Hz

kW

RANGE OF

OVERLOAD

RELAY (A)

MÁX. RATED

CURRENT Ie

(A)

CONTACTOR TYPE

STOCK CODE

CONTROL VOLTAGE

230 VAC

STOCK CODE

CONTROL VOLTAGE

400 VAC

STOCK CODE

& CONTROL

VOLTAGE 500 VAC

PRICE EACH

(ZAR)

Size 02 - Enclosure dimensions: H = 155mm x W = 90mm x D = 98mm

- 0.12 0.28...0.4 0.4 CW07 DLW-7P65-R01 10073251 10072767 N/A 859,00

- 0.18 0.4...0.63 0.63 CW07 DLW-7P65-R02 10073252 10071275 N/A 859,00

0.12 0.25 0.56...0.8 0.8 CW07 DLW-7P65-R03 10867909 10071276 N/A 859,00

0.18 0.37 0.8...1.2 1.2 CW07 DLW-7P65-R04 10867910 10682988 N/A 859,00

0.25 0.75 1.2...1.8 1.8 CW07 DLW-7P65-R05 10071281 10071277 N/A 859,00

0.37 1.1 1.8...2.8 2.8 CW07 DLW-7P65-R06 10071282 10186296 N/A 859,00

0.75 1.5 2.8...4 4 CW07 DLW-7P65-R07 10867911 10046219 N/A 859,00

1.1 2.2 4.0...6.3 6.3 CW07 DLW-7P65-R08 10689890 10046239 N/A 859,00

1.5 3.0 5.6...8 7 CW07 DLW-7P65-R09 10867915 10689892 N/A 859,00

RATED POWER

AC-3 / 50 Hz

kW

RATED POWER

AC-3 / 50 Hz

kW

RATED POWER

AC-3 / 50 Hz

kW

RANGE OF

OVERLOAD

RELAY (A)

MÁX. RATED

CURRENT Ie

(A)

CONTACTOR TYPE

STOCK CODE

CONTROL VOLTAGE

230 VAC

STOCK CODE

CONTROL VOLTAGE

400 VAC

STOCK CODE

& CONTROL

VOLTAGE 500 VAC

PRICE EACH

(ZAR)

Size 04 - Enclosure dimensions: H = 185mm x W = 105mm X D = 111mm

0,18 0,18 0,4...0,63 0,63 CWM9 DLW-9P65-R21 10075722 10075687 12384289 1082,00

0,12 0,25 0,25 0,56...0,8 0,8 CWM9 DLW-9P65-R22 10075723 10075688 12384296 1082,00

0,18 0,37 0,55 0,8...1,2 1,2 CWM9 DLW-9P65-R23 10075677 10075689 11607526 1082,00

0,25 0,75 0,75 1,2...1,8 1,8 CWM9 DLW-9P65-R24 10075678 10075690 11607527 1082,00

0,37 1,1 1,5 1,8...2,8 2,8 CWM9 DLW-9P65-R25 10075679 10074472 11335653 1082,00

0,75 1,5 2,2 2,8...4 4 CWM9 DLW-9P65-R26 10074473 10075691 11335654 1082,00

1,1 2,2 3 4,0...6,3 6,3 CWM9 DLW-9P65-R27 10074474 10075692 11335655 1082,00

1,5 3 4 5,6...8 8 CWM9 DLW-9P65-R28 10074475 10845656 11335656 1082,00

2,2 4 7...10 9 CWM9 DLW-9P65-R29 10689888 10046240 12384310 1082,00

3 5,5 5,5 8...12,5 12,5 CWM12 DLW-12P65-R30 10071283 10668184 11335657 1102,00

4 7,5 7,5 11...17 17 CWM18 DLW-18P65-R32 10977036 10046241 11335708 1182,00

9,2 9,2 15...23 23 CWM25 DLW-25P65-R33 Under request 10646245 12384312 1355,00

5,5 11 11 15...23 23 CWM25 DLW-25P65-R33 Under request 10075705 12384313 1355,00

Size 6 - Enclosure dimensions: H = 210mm x W = 120mm x D = 126mm

7,5 15 15 22...32 32 CWM32 DLW-32P65-R34 10075706 10724581 12384315 1785,00

9,2 18,5 18,5 25...40 40 CWM40 DLW-40P65-R35 10071285 10724693 12384317 2765,00

Different control voltage are available under request.

Enclosed Direct-On-Line Starter - DLW (IP65 / 50 Hz)

ENCLOSED DIRECT-ON-LINE STARTER THREE-PHASE - DLW

SIZE TYPE STOCK CODEPRICE EACH

(ZAR)

02 DLW-12D24P65-RM30 10211370 266,00

04 DLW-18D24P65-RM31 10686097 298,00

06 DLW-18D24P65-RM33 10686096 355,00

06 DLW-18D24P65-RM33 10211941 355,00

OVERLOAD RELAY NOT INCLUDED

Start + Stop/Reset (Standard)

Example: DLW-7D24P-R09

Enclosed Direct-On-Line Starter - DLWM

ENCLOSED DIRECT-ON-LINE STARTER SINGLE-PHASE - DLWM

INCLUDING OVERLOAD RELAY

Page 80: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

156 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 157

Enclosed Direct-On-Line Starter - Technical Data

ENCLOSED DIRECT-ON-LINE STARTERS DLW / DLWM - DIMENSIONS (MM)

Standard IEC/EN 60947

Operating temperature -20 0C...55 0C

Storage temperature -50 0C...80 0C

Degree of protection IP65

Mechanical lifespan (operation) 1 x 106

Electrical lifespan (operation) 1 x 105

Maximum number of operation per hour 15

Size 02 04 06

A 4.5 4.5 6.5

B 150 180 205

C 98 111 126

D 90 105 120

E 155 185 210

F - - -

FRAMES 02, 04 AND 06

DC

E

A

20

5

BM

6

Size 02 04 06

Superior part 2x PG16

or 2x 20 mm

2x PG16/21

or 2x 20/25 mmInferior part

ENCLOSURE SIZES CABLE KNOCK-OUTS SIZES

WEG Electronic Relays

High precision electronic circuit with noise immunity

Compact, with a 22.5 mm width frame, direct mounting on DIN rail 35 mm or fixed with screws

Equipped with reliability LED for status indications

STANDARDS

IEC / EN1812-1IEC / EN 60947-1IEC / EN 60947-5-1UL508 CAN/CSA C22.2

CERTIFICATIONS

Ideal for applications such as industrial processes, automation and motor

starters, RTW timing relays switch an output signal based on a selected

time and function.

With a 22.5 mm width frame the RTW is supplied as a competitive solution

including the following features:

Direct mounting on DIN rail 35 mm or fixed with screws

1 or 2 output contacts (NOC)

RE - On-Delay

RD - Off-Delay

RDI - Off-Delay without Control Voltage

PE - Impulse On

CI - Asymmetric Flasher Start ON

CIR - Asymmetric Flasher Start OFF

CIL - Symmetric Flasher - Start ON

CID - Symmetric Flasher - Start OFF

ET - Star - Delta

Timing Relay RTW

RTW Timing Relays with 2 timing ranges (adjustable from 0.1 sec up to 150 hours) and 9 functions

Compact, only 22.5 mm wide, can be assembled on DIN rail 35 mm or with screws

Provided with high precision electronic circuit and line noise immunity

LED for status indication

High reliability contacts

Page 81: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

158 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 159

Monitoring Relays RPW

Level Relay RNW

RPW monitoring relays are a competitive choice for monitoring voltage to protect against the most common types of electrical

failures. Monitoring voltages in electric installations are important for several reasons. Overvoltage, or phase loss, can cause

machinery and motors overheat, thus, reducing their lifetime. Phase sequence inversion can cause machinery to run in the

wrong way, destroying the entire system, and undervoltage may occur causing machinery to run in an undefined range, which

could cause some parts of a system to run properly while others cease operating.

With five different functions, the RPW series is ideal to be used in electric motor control panel applications.

These electronic control devices enable the monitoring and automatic level

adjustment of the electrical current liquid conductor. Widely used in reservoir

automation and can be used in several applications.

The RNW Level Relay line with 22.5 mm wide housing

offers the following functions:

RNW EN - Filling

RNW ES - Draining

RPW SF - Phase Sequence Relay

RPW FF - Phase Loss Relay

RPW FSF - Phase Sequence and Phase Loss Relay

RPW SS - Under and Overvoltage Relay

RPW PTC - Thermistor Relay

Timing Relays RTW

Ideal for applications such as industrial processes, automation and motor starters, RTW timing relays switch an output signal

based on a selected time and function.

With a 22.5 mm width frame the RTW is a competitive solution with:

Direct mounting on DIN rail 35 mm or fixed with screws using the PLMP accessory

1 or 2 output contacts (NO/NC)

Wide Supply voltage: 24-240 V ac 50/60 Hz / V dc

2 timing ranges, adjustable from 0.1 seconds to 150 hours, with 9 different functions

Offered in the following timing functions:

RTW- RE On-Delay

RTW- RD Off-Delay

RTW- RDI Off-Delay without Control Voltage

RTW- PE Impulse On

RTW- CI Asymmetric Flasher Start ON

RTW- CIR Asymmetric Flasher Start OFF

RTW- CIL Symmetric Flasher - Start ON

RTW-CID Symmetric Flasher - Start OFF

RTW- ET Star - Delta 1)

STANDARDS

CERTIFICATIONS

IEC / EN1812-1

IEC / EN 60947-1

IEC / EN 60947-5-1

RTW - _ _ 01 - U030S E05Timing relay

Timing range

MAT - 0.1 second to 10 minutes 2)

MBT - 0.2 second to 150 hours 2)

U001S - 0.1 to 1 second 3)

U003S - 0.3 to 3 seconds 3)

U010S - 1 to 10 seconds 3)

U030S - 3 to 30 seconds 3)

U060S - 6 to 60 seconds 3)

U100S - 10 to 100 seconds 2)

U300S - 30 to 300 seconds 3)

Voltage supply:

According to following table

Type

RE - On-Delay

PE - Impulse On

CI - Asymmetric Flasher Start ON

CIR - Asymmetric Flasher Start OFF

CIL - Symmetric Flasher - Start ON

CID - Symmetric Flasher - Start OFF

RD - Off-Delay

RDI - Off-Delay without Control Voltage

ET - Star - Delta 1)

Code Voltage RTW-RE RTW-PE RTW-CI RTW-CIR RTW-CIL RTW-CID RTW-RD RTW-RDI RTW-ET

E05 24-240 V ac 50/60 Hz / V dc X X X X X X X X X

E26 24 V ac 50/60 Hz / 24 V dc X X

E33 48 V ac 50/60 Hz / 24 V dc X X

E37 110-130 V ac 50/60 Hz / 24 V dc X X

E40 220-240 V ac 50/60 Hz / 24 V dc X X

Notes: 1) Star-Delta function requiers 2 output contacts and MAT timing range;

2) Timing ranges not avaliable for RTW-CI/CIR/RDI;

3) Timing ranges avaliable for RTW-CI/CIR/RDI.

SELECTION

R

Number of output contacts

01 - 1 Output contact

02 - 2 Output contacts

Page 82: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

160 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 161

Operating mode Timing diagram

RTW RE (ON - Delay) - Connecting a supply voltage on terminals A1-A2 / A3-A2 the selected time delay begins and

the green LED switches on. After the end of the delay time the output relay picks up (red LED turns on) and remains

energized until the supply voltage is removed. This can be repeated as often as required.

Reset: Removing supply voltage resets the time delay and the output.

SupplyA1 - A2 / A3 - A2

Output15 - 18 / 25 - 28

t

RTW PE (Impulse On) - Connecting a supply voltage on terminals A1-A2 / A3-A2 (green LED turns on) the output relay

picks up without delay (red LED turns on) and remains energized until the selected pulse time elapse (red LED turns

OFF). This can be repeated as often as required.

Reset: Removing supply voltage resets the time delay and the output.

SupplyA1 - A2 / A3 - A2

Output15 - 18 / 25 - 28

t

RTW RD (OFF Delay) - This function requires continuous supply voltage on terminals A1-A2 (green LED turns on) and

timing is controlled by a command contact at terminals A2-B1. If the command contact is energized, the output relay

picks up (red LED turns on) and after the command contact is removed the selected time delay begins. When the

selected time elapses the output relay is de-energized (red LED turns OFF). This can be repeated as often as required.

Reset: Removing supply voltage resets the time delay and the output.

SupplyA1 - A2 / A3 - A2

CommandA1 - B1

Output15 - 18 / 25 - 28

t t

RTW RDI (OFF Delay with no control) - Connecting a supply voltage on terminals A1-A2 / A3-A2, the green LED turns on

and the output relay picks up without delay (red LED turns on). If the supply voltage is de-energized, the selected time

delay begins and when this time elapses, the output relay is de-energized (red LED turns OFF). This can be repeated as

often as required.

Reset: Removing supply voltage resets the time delay and the output.

SupplyA1 - A2 / A3 - A2

Output15 - 18 / 25 - 28

t t

RTW CI (Asymmetric Flasher Start ON) - Connecting a supply voltage on terminals A1-A2 / A3-A2 the green LED turns

on and the timer starts to pulse with adjustable ON/OFF cycles. The upper dial presets the ON time (red LED turns ON

and output relay picks up) and the lower selects the OFF time when the output relay is de-energized.

Reset: Removing supply voltage resets the time delay and the output.

SupplyA1 - A2 / A3 - A2

Output15 - 18 / 25 - 28

tonton toff toff ton

RTW CIR (Asymmetric Flasher Start OFF) - Connecting a supply voltage on terminals A1-A2 / A3-A2 the green LED

turns on and the timer starts to pulse with adjustable OFF/ON cycles. The upper dial presets the ON time (red LED turns

ON and output relay picks up) and the lower select the OFF time when the output relay is de-energized.

Reset: Removing supply voltage resets the time delay and the output.

SupplyA1 - A2 / A3 - A2

Output15 - 18 / 25 - 28

tontoff toff toffton

RTW CIL (Symmetric Flasher -Start ON) - Connecting a supply voltage on terminals A1-A2 / A3-A2 the green LED turns

on and the timer starts to pulse with symmetric ON/OFF cycles. The dial presets a fixed ON time (red LED turns ON and

output relay picks up) and OFF time.

Reset: Removing supply voltage resets the time delay and the output.

SupplyA1 - A2 / A3 - A2

Output15 - 18 / 25 - 28

tt t tt

RTW CID (Symmetric Flasher - Start OFF) - Connecting a supply voltage on terminals A1-A2 / A3-A2 the green LED

turns on and the timer starts to pulse with symmetric OFF/ON cycles. The dial presets a fixed ON time (red LED turns ON

and output relay picks up) and OFF time.

Reset: Removing supply voltage resets the time delay and the output.

SupplyA1 - A2 / A3 - A2

Output15 - 18 / 25 - 28

tt t tt

RTW ET (Star-Delta) - Connecting a supply voltage on terminals A1-A2 / A3-A2 the output relay for the wye-connection

picks up and the adjusted time starts (red LED turns ON). When the start-up time elapses, a fixed star-delta changeover

time of 100ms starts and after this star-delta changeover time elapses the output relay for the delta-connection picks

up and stays energized until the supply is disconnected.

Reset: Removing supply voltage resets the time delay and the output.

SupplyA1 - A2 / A3 - A2

Output Y15 - 18

Output 25 - 28

tm

t

Note: where: t, tON, tOFF adjusted time, t

M Dead time.

Functions Characteristics

CONNECTION

Diagrams

LIGHT INDICATIONS ON RELAY

The RTW Timing Relay has status indicator LEDs, as shown below:

TIMING RELAY ADJUSTMENT

The desired timing must be adjusted through its front adjustment DIAL, the scale of which is presented in seconds for all timing,

except for the 3 to 30 minute scale.

RTW - ET

Red LED Star output

Green LED Delta output

The RTW relays can be individually mounted on DIN 35 mm rail or with screws using the PLMP accessory.

RTW-CI / CIR / RDI RTW-RE / PE / CIL / CID / RD RTW-ET

0.1 sec to 1 sec

0.1 sec to 10 min

0.2 sec to 150 h0.1 sec to 10 min

0.3 sec to 3 sec

1 sec to 10 sec

3 sec to 30 sec

6 sec to 60 sec

30 sec to 300 sec

3 min to 30 min

RTW-RE RTW-PE RTW-CI/CIL/CID/CIR RTW - RD / RDI RTW - ET

1E 2E 1E 2E 1E 2E 1E 2E 2E

Term

inal

pos

itio

ns

15A1

16 18 A2

RTW RE

A3 15

26 28

A1

25

16 18 A2

RTW RE

A3 15 A3A1

RTW PE

18 A216

15 A3

26

18

28

A2

A1

25

16

RTW PE

15 A3A1

RTW CI

18 A216

15 A3

26

18

28

A2

A1

25

16

RTW CI

15 B1A1

16 18 A2

RTW RD

15 B1

26 28

A1

25

16 18 A2

RTW RD

15 A3

26

18

28

A2

A1

25

16

RTW ET

RTW-RE01 RTW-RE02 RTW-PE01 RTW-PE02 RTW-C..01 RTW-C..02 RTW-R..01 RTW-R..02

Dia

gra

mC

ircu

it

A1 - A2

supply voltage

24-240 V ac/ V dc

(50/60 Hz)

24-240 V ac/ V dc

(50/60 Hz)

220-240 V, 24-240 V ac/ V dc

(50/60 Hz)

24-240 V ac/ V dc

(50/60 Hz)

24-240 V ac/ V dc

(50/60 Hz)

A2 - A3

supply voltageVoltage 24 V dc Voltage 24 V dc Voltage 24 V dc X Voltage 24 V dc

A2 - B1

control voltageX X X

Voltages 24-240 V ac/ V dc

(50/60 Hz)X

15 - 16 - 18 Output 1 Output 1 Output 1 Output 1 Output 1

25 - 26 - 28 Output 2 Output 2 Output 2 Output 2 Output 2

Page 83: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

162 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 163

Monitoring Relays RPW

WEG RPW Relays are electronic devices that protect three-phase systems against phase loss or selectable neutral loss

(RPW FF), phase sequence inversion (RPW SF) or both of the functions integrated into the same product (RPW FSF). Whenever

there is failure in the three-phase system the relay will work to interrupt the motor of process operation to be protected.

Designed in accordance with international standards, the RPW Monitoring Relays offer a compact and competitive solution, with

22.5 mm wide housing for assembly on DIN 35 mm rail.

The Phase Sequence Relay is designed to protect three-phase systems against phase

sequence inversion (L1-L2-L3).

Functioning: on connecting the relay to the supply with the phase sequences correctly

connected, the output relay switches the contacts to operation position (closing terminals 15-

18) and the red LED turns on. When a phase sequence inversion occurs the output contacts

will become de-energized (opening 15-18) and the red LED will turn OFF.

STANDARDS CERTIFICATIONS

IEC / EN 60947-1

IEC / EN 60947-5-1

RPW SF

LIGHT INDICATORS ON RELAY

CONNECTION DIAGRAMS

The RPW monitoring relay is

equipped with status indicator

LEDs, as shown on the right:

The RPW relays can be individually mounted

on DIN 35mm rail or with screws using the

PLMP accessory.

ASSEMBLY

L1 L2 L3

16 18

15

L1 L215

16 18 L3

RPW SF

Energized output

Energized relay

RPW - SF - D66

Phase sequence

Supply voltage selection.

According to following table:

Available voltages:

D66 = 220-240 V ac 50/60 Hz

D70 = 380-415 V ac 50/60 Hz

D74 = 440-480 V ac 50/60 HzWEG monitoring relay

FUNCTIONAL DIAGRAM

t

V

L1-L2-L3 InversionL1-L2-L3

LEDON

LEDOFF

15

1816

15

1816

L1-L2-L3

Output15 - 18

Power Supply

LED

SELECTIONCONNECTION DIAGRAMS

RPW FF (NEUTRAL NOT SELECTED)

The Phase Loss Relay is designed to protect three-phase systems against phase loss with

feedback.

Functioning: Directly connected to the supply to be monitored, feeding the 3-phases with phase

amplitude within the selected limits, the output relay switches the contacts to operation position

(closing terminals 15-18) and the red LED switches on. When loss occurs in one of the phases

in relation to the others to a value below the percentage limit selected through the sensitivity

adjustment DIAL (monitoring against motor ghost phase) the output contact (opening 15-18) will

become de-energized and the red LED indicating system running will switch OFF.

RPW FF (NEUTRAL SELECTED)

Designed to protect three-phase systems with neutral.

Functioning: In the same product, a bridge must be provided between terminals A and B for

neutral monitoring. The relay will perform the same monitoring for phase loss and will also monitor

the voltage in neutral, which must be connected. When this value exceeds 20 V, there will be

output de-energization (opening 15-18). A value considered unbalanced loads.

RPW FF

Notes: - When we monitor a motor, the current of the remaining phases increases generated by a phase loss, which will cause motor overheating;

- Winding with armature voltage works as a voltage generator, called “ghost phase”. The RPW FF will protect the motor in the situation.

ASSEMBLY

The RPW relays can be individually mounted on DIN 35 mm rail or with screws using the PLMP accessory.

L1 15 L2

RPW FF

A B N

L1 L2 L3

A B N

Neutral selection

16 18

15

16 18 L3

RELAY LIGHT INDICATIONS

Monitoring relay RPW has

status indicating LEDs, as

shown on the right:

Energized output

Energized relay

SENSITIVITY ADJUSTMENT

Relay sensitivity adjustment

must be performed through

the adjustment Dial located on

the front. Adjust the desired

percentage from 70 to 90%,

which will define the loss

percentage of a phase in

relation to the others.

FUNCTIONAL DIAGRAM

L1-L2-L3L1-L2

L3

L3

Phase or neutral loss

L1-L2

V

LEDON

LEDOFF

LEDOFF

15

1816

15

1816

15

1816

L1-L2-L3

Output15 - 18

Power Supply

Sensitivity

Adjustment

90 to 70% Un

Nominal Voltage

Un

LED

t

SELECTION

RPW - FF - D66

WEG monitoring relay

Supply voltage selection.According to below table:Available voltages:D66 = 220-240 V ac 50/60 HzD70 = 380-415 V ac 50/60 HzD74 = 440-480 V ac 50/60 HzPhase loss

Page 84: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

164 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 165

RELAY LIGHT INDICATIONS SENSITIVITY ADJUSTMENT

CONNECTION DIAGRAMS FUNCTIONAL DIAGRAM

RPW FSF (NEUTRAL NOT SELECTED)

The Phase Loss and Sequence Relay is designed to protect three-phase systems against

phase loss and reversions. Functioning: directly connected to the supply to be monitored,

supplying the 3-phases and the phase amplitude to be within the selected limits and in the

correct sequence, the output relay switches the contacts to the work position (closing terminals

15-18) and the red LED will switch on. When phase loss or reversion occurs the output

contacts (opening 15-18) become de-energized and the red LED indicating system running

switch OFF.

RPW FSF (NEUTRAL SELECTED)

In the same product, a “jumper„ must be made between terminals A and B for neutral

monitoring, the relay will perform the same monitoring for phase loss and balancing and will

also monitor the voltage in neutral, which must be connected. When the voltage at neutral

exceeds 20 V, value that considers unbalanced loads, there will be output de-energization

(opens 15-18).

RPW FSF

ASSEMBLY

The RPW relays can be individually mounted on DIN 35mm rail or with screws using the PLMP accessory.

Monitoring relay RPW has

status indicating LEDs, as

shown on the right:

Energized output

Energized relay

Relay sensitivity adjustment must be

performed through the adjustment Dial

located on the front, adjust the desired

percentage from 70 to 90%, which will

define the loss percentage of a phase

in relation to the others.

L1 15 L2

16 18 L3

RPW FSF

A B N

L1 L2 L3

A B N

Neutral selection

16 18

15

Phaseinversion L1-L2-L3L1-L2-L3L1-L2

L3

L3

Phase or neutral loss

L1-L2

V

LEDON

LEDOFF

LEDOFF

LEDOFF

15

1816

15

1816

15

1816

15

1816

L1-L2-L3

Output15 - 18

Power Supply

LED

t

Sensitivity

Adjustment

90 to 70% Un

Nominal Voltage

Un

SELECTION

RPW - FSF - D66

Phase loss and sequence

Supply voltage selection.

According to below table:

Available voltages:

D66 = 220-240 V ac 50/60 Hz

D70 = 380-415 V ac 50/60 Hz

D74 = 440-480 V ac 50/60 HzWEG monitoring relay

RPW SS

The WEG RPW SS Relay is designed to protect three-phase systems against under or over

voltage and phase loss.

Functioning: directly connected to the 3-phases to be monitored (L1, L2 and L3) and being the

phases amplitude within the sensitivity limits adjusted on the front scales, the relay switches the

contacts to the operation position, (closing terminals 15 - 18) and the red LED will switch on.

When any failure occurs in the system causing under or over voltage or even phase loss relay

de-energization will occur (opening terminals 15 - 18) protecting the monitored equipment and

the red LED turns OFF.

ASSEMBLY

The RPW relays can be individually mounted on DIN 35 mm rail or with screws using the PLMP accessory.

SELECTION

RPW - SS - D77

WEG monitoring relay

Voltage selection according to the below table:

Available voltages:

D77 = 208 V ac 50/60 Hz

D23 = 220 V ac 50/60 Hz

D24 = 230 V ac 50/60 Hz

D25 = 240 V ac 50/60 Hz

D33 = 380 V ac 50/60 Hz

D34 = 400 V ac 50/60 Hz

D35 = 415 V ac 50/60 Hz

D36 = 440 V ac 50/60 Hz

D38 = 460 V ac 50/60 Hz

D39 = 480 V ac 50/60 HzUnder and over voltage

SENSITIVITY ADJUSTMENT

FUNCTIONAL DIAGRAMCONNECTION DIAGRAMS

RELAY LIGHT INDICATIONS

L1 L2 L3

16 18

15

L1 15 L2

16 18 L3

RPW SS

The sensitivity adjustment is

performed by 2 dials located on the

front of the Relay. Selection is from

-15% to -3% (for under voltage) and

+3% to +15% (for over voltage).

On

Off

Normal Operation

Under, Overvoltage and

Phase loss

On Energized

Off Energized

L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3

Overvoltage

Phaseloss Asymmetry

Undervoltage

V

LEDON

LEDOFF

LEDOFF

LEDOFF

LEDOFF

15

1816

15

1816

15

1816

15

1816

15

1816

L1-L2-L3

Output15 - 18

Power supply

Lower

limit

Upper

limit

LED

t

Page 85: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

166 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 167

CONNECTION DIAGRAMS

The WEG RPW PTC Relay is an electronic monitoring device enabling monitoring against

temperatures in excess of the given limit by PTC selection in machines (motors, generators,

etc...) equipped with a PTC temperature detector.

Designed in accordance with international standards, the RPW PTC offers a safe and compact

solution, with standardized 22.5 mm boxes for insertion in DIN rail 35 mm.

Functioning: The RPW-PTC relay has status indication through the LEDs located on the front

of the product. The green LED is ON when the relay is energized. If the monitored temperature

by the PTC is below the defined value of 3.5 kΩ, the red LED will be ON indicating normal

operation. Therefore, if the resistance exceeds the limit of 3.5 kΩ, the relay will instantaneously

switch the outputcontacts and the red LED will be OFF indicating an over temperature

condition of the motor. The relay will only switch on the 15 and 18 contacts again once the

temperature goes down to normal values.

Additionally, the WEG PTC relay provides sensor testing feature.In case of failure of the PTC

sensors, the green LED will be FLASHING. This feature indicates that the PTC sensors are

either open or in shortcircuit (20 Ω or less).

RPW PTC

A1 15

16 18 A2

RPW PTC

S1 S2

RELAY LIGHT INDICATIONS

A1 - A2 Voltage supply 24...240 V ac / V dc

S1 - S2 PTC sensor input

15 - 16 - 18 Output

TERMINALS

ASSEMBLY

The RPW relays can be individually mounted on DIN 35 mm rail or with screws using the PLMP accessory.

SELECTION

On Normal operation

Off Elevated temperature

On Energized

Off Not energized

Flashing PTC sensor failure

FUNCTIONAL DIAGRAM

RPW - PTC - E 16

WEG monitoring relay PTC detector

Available voltage range:

E05= 24-240 V ac/dc

The WEG Level Relays are electronic control devices that enable the monitoring and automatic adjustment of the level in electric

current liquid conductors. Widely used in reservoir automation in general, the RNW relays can be used in several applications

such as the prevention of dry pump operation, monitoring against filling tank overflow, activation of solenoids or alarms / lighting.

The operating principle is based on the measuring of the electrical resistance of the reservoir liquid through an assembly of

electrodes that work as liquid presence / absence sensors. To optimize their performance, the relay has a sensitivity DIAL

enabling the electronic circuit to be adjusted to the liquid resistance.

Available in 2 distinct functions, RNW EN filling and RNW ES draining, the relay offers digital electronics that provide high

precision, repeatability and noise resistance. The supply system is isolated from the electronic circuit therefore ensuring greater

user safety. Designed in accordance with international standards, the RNW offers a safe and compact solution, in 22.5 mm wide

housing for assembly on DIN rail 35 mm, with 1 output with NO/NC reversable contact and an ample voltage supply range of 100-

240 V ac/ V dc.

STANDARDS

CERTIFICATIONS

IEC / EN 60947-1

IEC / EN 60947-5-1

Available in the following functions:

RNW EN Filling

RNW ES Draining

SELECTION

FUNCTIONING

The electrodes are fixed in the reservoir according to desired levels for

control, minimum or maximum, and the reference electrode (C) must be

positioned in the lower part, below the other electrodes, maximum level

electrode (Max) and minimum level etectrode (Min). When the system is

energized an alternating current (the AC current minimizes the electrolysis

and increases the life span of the electrode) is applied to the reference

electrode, once the liquid comes into contact with the level electrodes

a path is established for the circulation of electrical current between the

electrodes. An electronic current compares the current and according to

the chosen model (RNW ES or RNW EN) a logic will occur that switches

the relay output contacts. The electrodes are available in 2 models, shaft

(EHW) or pendulum (EPW), the difference between them is the way of

fixing. In order to adapt the several applications the RNW is available in

two distinct functions, draining and filling.Note: the EHW can be fixed both horizontally and vertically.

MaxElec

Min Elec

C Elect.

Pendulum Type Shaft Type

MaxElec

MinElec

C Elect

RNW - _ _ - E 09

WEG level relay

Available voltage range

E09 = 100-240 V ac/ V dc

Type: EN - Filling

ES - Draining

Level Relays RNW

Page 86: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

168 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 169

Functional DiagramConnection Diagram

Controls 2 levels using the 3 electrodes, the reference electrode (C), the maximum level electrode

(Max) and the minimum level electrode (Min). Once supplied the RNW ES checks the liquid level

in the reservoir, with this being in contact with the Max level electrode, the relay will become

energized (terminals 15-18 closed), causing the reservoir liquid level begin to drop. Once the Min

level electrode is uncovered by the liquid the relay will switch to rest status (terminals 15-18 open)

and will thus remain until the liquid enters into contact again with the Max level electrode, restarting

the process. If there is a relay supply failure when resupplying the RNW ES verifies the liquid level

and restarts its initial logic.

RNW ES (Draining)

Controls 2 levels using the 3 electrodes, the reference electrode (C), the maximum level electrode

(Max) and the minimum level electrode (Min). Once supplied the RNW EN monitors the liquid level

in the reservoir, with the electrode being uncovered at minimum level Min, the output relay will

become energized (terminals 15-18 closed) causing the liquid level to rise. When the reservoir

liquid covers the Max level electrode, the relay goes into a state of rest (terminals 15-18 open) and

thus remains until the Min level electrode is discovered again. If there is a relay supply failure when

resupplying the RNW EN monitors the liquid level and restart its initial logic.

RNW EN (Filling)

Level

15 15 15

16 16 1618 18 18

LEDOFF

LEDOFF

LEDOFF

15 15 15

16 16 1618 18 18

LEDON

LEDON

LEDON

t

15 - 18

C

Min

Max

Supply voltageA1-A2

A1 15

16 18 A2

RNW EN

Max Min C

Max Min

15

1816

C

Functional DiagramConnection Diagram

A1 15

16 18 A2

RNW ES

Max Min CSupply voltage

A1-A2

Level

15 15

16 1618 18

LEDOFF

LEDOFF

15 15 15

16 16 1618 18 18

LEDON

LEDON

LEDON

t

15 - 18

C

Min

Max

Max Min

15

1816

C

RTW Technical Data

Inp

uts

Reference code RTW

Rated insulation voltage V 300

Supply voltage (Ue)

A1-A2

V ac 24-240 V ac/ V dc (50/60 Hz)

220-240 V. 24-240 V ac/ V dc (50/60 Hz)

24 V dc. 24-240 V ac/ V dc (50/60 Hz)

380-440 V. 24-240 V ac/ V dc (50/60 Hz)

A2-A3 V dc 24 V dc

Control (Uc) (only RTW RD)

A2-B1 V ac 24-240 V ac/ V dc (50/60 Hz)

Voltage limits 0.85...1.1 x Uc for V ac

0.8...1.25 x Uc for V ac

Consumption mA 35 for Ue = 24 V dc

65 for Ue = 110 V ac

75 for Ue = 130 V ac

55 for Ue = 220 V ac

60 for Ue = 240 V ac

Tim

e ad

just

Minimun time for reset ms 100

Minimun ON time (for RTW RD) ms 50

Setting accuracy (as % of the full scale value) % +/- 5

Repeat accuracy % +/- 1

Changeover time Y - Δ ms 100

Ou

tpu

ts

Output contacts capacity (Ie)

A

AC-15 in 230 V ac

DC-13 in 24 V dc

DC-13 in 48 V dc

DC-13 in 60 V dc

DC-13 in 125 V dc

DC-13 in 250 V dc

A300: AC-15

R300: DC-13

3

1

0.45

0.35

0.2

0.1

Rated thermal current (lth) A 10 (for AC)

2.5 (for DC)

Fuse (class gL/gG) A 4

Mechanical lifespan operating

cycles30 x 106

Ch

arac

teri

stic

s

Ambient temperature

- Operation 0C -5 to +60

- Storage 0C -40 to +85

Degree of protection IP20

Connection section (min. to max)

- Cable without end sleeve

- Cable with end sleeve

- AWG-Wire

mm2

mm2A

AWG

1 x (0.5 to 2.5)

2 x (0.5 to 2.5)

1 x (0.5 to 2.5)

2 x (0.5 to 2.5)

2 x (20 to 16)

Tightening torque N.m

lb.in.

0.8 to 1.2

7 to 10.6

Terminal screw M3

Assembly position Any

Shock resistance g/ms 15/11

Resistance vibration Hz/mm 10 to 500/10

Weight KG 0.08 (1E)

0.095 (2E)

Page 87: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

170 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 171

RPW Technical Data

Inp

uts

Reference code RPW FF RPW SF RPW FSF RPW SS RPW PTC

Supply (Us) L1 - L2 - L3 V ac Voltage ranges (220 up to 480 (select) ) 24...240 V ac/ V dc

Frequency Hz 50/60

Sensitivity adjustment % 70 to 90 - 70 to 90 - /+ 3 to 15% -

Operation limits Us 0.85 to 1.1 x Us for V ac

Maximum consumption mA 80

Maximum voltage allowed in neutral V 20 - 20 - -

Scale precision (scale base) % + / - 20 - -

Ou

tpu

ts

Repeatibility precision % + / - 1 - -

Maximum capacity of

Output contacts (Ie)

Resistive

load5

AC-15 (A) 3

Fuse (class gL/gG) A 4

Mechanical lifespan op-

erations30 x 106

Ch

arac

teri

stic

s

Electrical lifespan op-

erations10 x 105

Ambient temperature allowed -

- Operation °C -5 to +60

- Storage °C -40 to +85

Degree of protection IP 20

Terminal capacity

- Wire mm21 x (0.5 to 2.5)

2 x (0.5 to 1.5)

- Cable with terminal mm21 x (0.5 to 1.5)

2 x (0.5 to 1.5)

- AWG solid conductor AWG 2 x (20 to 14)

Tightening torque N.m

lb.in

0.8 to 1.2

7 to 10.6

Terminal screw M3

Assembly position Any

Shock resistance g/ms 15/11

Resistance vibration Hz/g 10 to 500/10

Weight kg 0.1

Pollution 2

Overvoltage category III

RNW Technical Data

Inp

uts

Reference code RNW ES / RNW EN

Supply (Un) A1 V ac 100-240 50 /60 Hz

A2 V dc 100-240

Isolated rated voltage (Ui) V 300

Operating limits 0.85 to 1.1 x Ue

Maximum consumption VA / W 2 / 1

Ou

tpu

ts

Contacts

15 - 16 / 181 SPDT

Output contact capacity (Ie)

A

5 (resistive load)

AC-15 in 230 V ac 3

DC-13 in 24 V dc 1

DC-13 in 48 V dc 0.45

DC-13 in 60 V dc 0.35

DC-13 in 125 V dc 0.2

DC-13 in 250 V dc 0.1

A300 : AC-15

R300 : DC-13

Rated thermal current (lth) A10 (for AC)

2.5 (for DC)

Fuse (class gL / gG) A 4

Mechanical lifespan Operations 30 x 106

Ch

arac

teri

stic

s

Temperature

Operation °C

-5 to +60

Storage -40 to +85

Degree of protection IP20

Terminal capacity Rigid or fexible cable mm21 x (0.5 to 2.5)

2 x (0.5 to 1.5)

Cable with terminalRigid or fexible cable/terminal mm2

1 x (0.5 to 2.5)

2 x (0.5 to 1.5)

AWG solid conductor AWG 2 x (30 to 14)

Tightening torqueN.m 0.8 to 1.2

lb.in 7 to 10.6

Terminal screws M3

Assembly position Any

Resistance to impacts g / ms 15 / 11

Resistance to vibration Hz / mm 10 to 500 / 10

Weight kg 0.08

Pollution 2

Over voltage category II

Sensitivity adjustment kΩ 0 to 100

Electrode voltage V ac 7

Det

ecto

rs

Electrode current mA 0.05

Maximum length of sensor cable m 100 (Maximum cable capacitance 2.2nF)

Detector operating temperature

- Shaft °C0 to + 260

- Pendulum 0 to + 60

Allowable detector pressure

- Shaft kgf / cm23

- Pendulum -

Detector weight

- Shaft kg0.230

- Pendulum 0.012

Page 88: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

172 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 173

DIMENSIONS (MM)

RELAY ASSEMBLY

Electronic Relay Technical Data

10

4.7

7

74

.55

85.50

12.7

80

4.80

91

.3

22.5

Multifunction Electronic Timer Relays

FUNCTION CONTACTS VOLTAGE TIME RANGE TYPE SAP CODEPRICE EACH

(ZAR)

On-delay (A)

Off-delay with control signal (Ba)

On- and Off-delay with control signal (Ca)

Symmetrical flasher, starts with pulse on (Da)

Symmetrical flasher, starts with pulse off (Db)

Interval (E)

Retriggerable interval with control signal off (Fa)

Star-Delta (G)

2NOC

24-240 V

50/60 Hz

24-240 V dc/cc

0.1s...10 d ERWT-MF1-02MT1E05 11593741 1286,00

ON and OFF delay with control signal (Cb)

Asymetrical flasher, starts with pulse OFF (Dd)

Percentage fasher, starts with pulse OFF (Df)

Delayed adjustable-length pulse (Ia)

Asymmetrical fasher, starts with pulse ON (Dc)

Percentage fasher, starts with pulse ON (De)

Flasher to reversing motor (Dg)

Bistable (J)

2NOC

24-240 V

50/60 Hz

24-240 V dc/cc

0.1s...10 d ERWT-MF2-02MT1E05 12074471 1286,00

FUNCTION CONTACTS VOLTAGE TIME RANGE TYPE SAP CODEPRICE EACH

(ZAR)

Phase loss (PF) Overvoltage (>Un) Unbalance

(Asy) Phase Sequence (PS) Undervoltage (<Un)

Neutral detection (ND)

1NOC208-480 V

50/60 Hz0(OFF)...30s ERWM-VM1-01D90 12337266 1834,00

Phase loss (PF) Overvoltage (>Un) Unbalance

(Asy) Undervoltage (<Un) Neutral detection

(ND)

1NOC208-480 V

50/60 Hz0(OFF)...30s ERWM-VM2-01D90 12074470 1834,00

Multifunction Three-Phase Monitoring Relays

wwwww..zestt.coo.zzaa

TTTTTTTTiiiiiiiimmmeeerrr RRRRRRRReeellllllllaaayyysss

The New Generation of WEG Components for Motor Starting and Protection

Page 89: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

174 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 175

Electronic Timer Relays

RTW RE - ON DELAY

RTW PE - IMPULSE-ON

RTW CI - PULSE FLASHER - START ON

RTW CIR - PULSE FLASHER - START OFF

CONTACTS RATED VOLTAGE (V) TIME RANGE TYPE STOCK CODEPRICE EACH

(ZAR)

1NOC24-240 V 50/60 Hz

24-240 VDC

0.1s...10min RTW-RE01-MATE05 10753278 688,00

0.2s...150h RTW-RE01-MBT-E05 10753335 688,00

2NOC24-240 V 50/60 Hz

24-240 VDC

0.1s...10min RTW-RE02-MAT-E05 10753285 734,00

0.2s...150h RTW-RE02-MBT-E05 10753337 734,00

CONTACTS RATED VOLTAGE (V) TIME RANGE TYPE STOCK CODEPRICE EACH

(ZAR)

1NOC24-240 V 50/60 Hz

24-240 VDC

0.1s...10min RTW-PE01-MAT-E05 10753298 688,00

0.2s...150h RTW-PE01-MBT-E05 10753358 688,00

2NOC24-240 V 50/60 Hz

24-240 VDC

0.1s...10min RTW-PE02-MAT-E05 10753300 734,00

0.2s...150h RTW-PE02-MBT-E05 10753359 734,00

CONTACTS RATED VOLTAGE (V) TIME RANGE TYPE STOCK CODEPRICE EACH

(ZAR)

1NOC24-240 V 50/60 Hz

24-240 VDC

0.3s...3s RTW-CI01-U003SE05 10118415 688,00

1s...10s RTW-CI01-U010SE05 10118416 688,00

3s...30s RTW-CI01-U030SE05 10118417 688,00

6s...60s RTW-CI01-U060SE05 10118418 688,00

10s...100s RTW-CI01-U100SE05 10118419 688,00

30s...300s RTW-CI01-U300SE05 10118420 688,00

3min...30min RTW-CI01-U030ME05 10118421 688,00

2NOC24-240 V 50/60 Hz

24-240 VDC

0.3s...3s RTW-CI02-U003SE05 10118422 734,00

1s...10s RTW-CI02-U010SE05 10118423 734,00

3s...30s RTW-CI02-U030SE05 10118424 734,00

6s...60s RTW-CI02-U060SE05 10117808 734,00

10s...100s RTW-CI02-U100SE05 10117809 734,00

30s...300s RTW-CI02-U300SE05 10117810 734,00

3min...30min RTW-CI02-U030ME05 10117811 734,00

CONTACTS RATED VOLTAGE (V) TIME RANGE TYPE STOCK CODEPRICE EACH

(ZAR)

1NOC24-240 V 50/60 Hz

24-240 VDC

0.3s...3s RTW-CIR01-U003SE05 10117826 688,00

1s...10s RTW-CIR01-U010SE05 10117827 688,00

3s...30s RTW-CIR01-U030SE05 10117828 688,00

6s...60s RTW-CIR01-U060SE05 10117829 688,00

10s...100s RTW-CIR01-U100SE05 10117830 688,00

30s...300s RTW-CIR01-U300SE05 10117831 688,00

3min...30min RTW-CIR01-U030ME05 10117832 688,00

2NOC 24-240 V 50/60 Hz

24-240 VDC

0.3s...3s RTW-CIR02-U003SE05 10117833 734,00

1s...10s RTW-CIR02-U010SE05 10117834 734,00

3s...30s RTW-CIR02-U030SE05 10117835 734,00

6s...60s RTW-CIR02-U060SE05 10117836 734,00

10s...100s RTW-CIR02-U100SE05 10117837 734,00

30s...300s RTW-CIR02-U300SE05 10117838 734,00

3min...30min RTW-CIR02-U030ME05 10117839 734,00

Electronic Timer Relays

RTW CIL - SYMMETRIC FLASHER - START ON

CONTACTS RATED VOLTAGE (V) TIME RANGE TYPE STOCK CODEPRICE EACH

(ZAR)

1NOC24-240 V 50/60 Hz

24-240 VDC

0.1s...10min RTW-CIL01-MAT-E05 10753331 688,00

0.2s...150h RTW-CIL01-MBT-E05 10753364 688,00

2NOC24-240 V 50/60 Hz

24-240 VDC

0.1s...10min RTW-CIL02-MAT-E05 10753332 734,00

0.2s...150h RTW-CIL02-MBT-E05 10753366 734,00

RTW ET - STAR-DELTA

CONTACTS RATED VOLTAGE (V) TIME RANGE TYPE STOCK CODEPRICE EACH

(ZAR)

2NOC24-240 V 50/60 Hz

24-240 VDC0.1s...10min RTW-ET02-MATE05 10753244 734,00

RTW CID - SYMMETRIC FLASHER - START OFF

CONTACTS RATED VOLTAGE (V) TIME RANGE TYPE STOCK CODEPRICE EACH

(ZAR)

1NOC24-240 V 50/60 Hz

24-240 VDC

0.1s...10min RTW-CID01-MAT-E05 10753328 688,00

0.2s...150h RTW-CID01-MBT-E05 10753361 688,00

2NOC24-240 V 50/60 Hz

24-240 VDC

0.1s...10min RTW-CID02-MAT-E05 10753329 734,00

0.2s...150h RTW-CID02-MBT-E05 10753363 734,00

RTW RD - OFF-DELAY

CONTACTS RATED VOLTAGE (V) TIME RANGE TYPE STOCK CODEPRICE EACH

(ZAR)

1NOC24-240 V 50/60 Hz

24-240 VDC

0.1s...10min RTW-RD01-MAT-E05 10753333 688,00

0.2s...150h RTW-RD01-MBT-E05 10753388 688,00

2NOC24-240 V 50/60 Hz

24-240 VDC

0.1s...10min RTW-RD02-MAT-E05 10753334 734,00

0.2s...150h RTW-RD02-MBT-E05 10753396 734,00

RTW RDI - OFF-DELAY NO CONTROL

CONTACTS RATED VOLTAGE (V) TIME RANGE TYPE STOCK CODEPRICE EACH

(ZAR)

1NOC24-240 V 50/60 Hz

24-240 VDC

0.3s...3s RTW-RDI01-U003SE05 10666337 688,00

1s...10s RTW-RDI01-U010SE05 10666358 688,00

3s...30s RTW-RDI01-U030SE05 10075553 688,00

6s...60s RTW-RDI01-U060SE05 10666359 688,00

10s...100s RTW-RDI01-U100SE05 10666361 688,00

30s...300s RTW-RDI01-U300SE05 10666362 688,00

60s...600s RTW-RDI01-U010ME05 10666365 688,00

2NOC24-240 V 50/60 Hz

24-240 VDC

0.3s...3s RTW-RDI02-U003SE05 10075554 734,00

1s...10s RTW-RDI02-U010SE05 10075555 734,00

3s...30s RTW-RDI02-U030SE05 10075556 734,00

6s...60s RTW-RDI02-U060SE05 10075557 734,00

10s...100s RTW-RDI02-U100SE05 10075558 734,00

30s...300s RTW-RDI02-U300SE05 10075559 734,00

60s...600s RTW-RDI02-U010ME05 10075560 734,00

Page 90: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

176 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 177

Electronic Timer Relays - Single Timing

RTW RE - ON DELAY

RTW RD - OFF-DELAY

RTW ET - STAR-DELTA

CONTACTS RATED VOLTAGE (V) TIME RANGE TYPE STOCK CODEPRICE EACH

(ZAR)

1NOC

24 VAC/DC

3s...30s RTW-RE01-U030SE26 10047116 520,00

6s...60s RTW-RE01-U060SE26 10075134 520,00

30s...300s RTW-RE01-U300SE26 10186733 520,00

110-130 VAC

24 VDC

3s...30s RTW-RE01-U030SE37 10452215 520,00

6s...60s RTW-RE01-U060SE37 10046611 520,00

30s...300s RTW-RE01-U300SE37 10046613 520,00

220-240 VAC

24 VDC

3s...30s RTW-RE01-U030SE40 10046610 520,00

6s...60s RTW-RE01-U060SE40 10354331 520,00

30s...300s RTW-RE01-U300SE40 10561995 520,00

380-440 VAC

3s...30s RTW-RE01-U030SD71 10261478 631,00

6s...60s RTW-RE01-U060SD71 10667359 631,00

30s...300s RTW-RE01-U300SD71 10667361 631,00

CONTACTS RATED VOLTAGE (V) TIME RANGE TYPE STOCK CODEPRICE EACH

(ZAR)

1NOC

24 VAC

3s...30s RTW-RD01-U030SD02 10666274 520,00

6s...60s RTW-RD01-U060SD02 10666275 520,00

30s...300s RTW-RD01-U300SD02 10075145 520,00

110-130 VAC

3s...30s RTW-RD01-U030SD61 10046619 520,00

6s...60s RTW-RD01-U060SD61 10046621 520,00

30s...300s RTW-RD01-U300SD61 10046624 520,00

220-240 VAC

3s...30s RTW-RD01-U030SD66 10046620 520,00

6s...60s RTW-RD01-U060SD66 10046622 520,00

30s...300s RTW-RD01-U300SD66 10046625 520,00

24 VDC

3s...30s RTW-RD01-U030SC03 10186469 520,00

6s...60s RTW-RD01-U060SC03 10073657 520,00

30s...300s RTW-RD01-U300SC03 10046628 520,00

CONTACTS RATED VOLTAGE (V) TIME RANGE TYPE STOCK CODEPRICE EACH

(ZAR)

2NOC

24VAC/DC 3s...30s RTW-ET02-U030SE26 10074345 601,00

110-130 VAC

24 VDC3s...30s RTW-ET02-U030SE37 10410345 601,00

220-240 VAC

24 VDC3s...30s RTW-ET02-U030SE40 10046635 601,00

380-440 VAC 3s...30s RTW-ET02-U030SD71 10118275 734,00

Note : The timing relays on this page are single supply voltage and single timing.

Electronic Monitoring Relays

VOLTAGE (V) TYPE STOCK CODEPRICE EACH

(ZAR)

220-240VAC 50/60Hz RPW-FFD66 10047121 801,00

380-415VAC 50/60Hz RPW-FFD70 10047122 801,00

440-480VAC 50/60Hz RPW-FFD74 10047123 801,00

VOLTAGE (V) TYPE STOCK CODEPRICE EACH

(ZAR)

220-240VAC 50/60Hz RPW-FSFD66 10047119 815,00

380-415VAC 50/60Hz RPW-FSFD70 10047120 815,00

440-480VAC 50/60Hz RPW-FSFD74 10074363 815,00

VOLTAGE (V) TYPE STOCK CODEPRICE EACH

(ZAR)

220-240VAC 50/60Hz RPW-SFD66 10047124 718,00

380-415VAC 50/60Hz RPW-SFD70 10186742 718,00

440-480VAC 50/60Hz RPW-SFD74 10410424 718,00

VOLTAGE (V) TYPE STOCK CODEPRICE EACH

(ZAR)

24-240V 50/60Hz/DC RPW-PTCE05 10075636 971,00

VOLTAGE (V) TYPE STOCK CODEPRICE EACH

(ZAR)

208VAC 50/60Hz RPW-SSD77 10583789 853,00

220VAC 50/60Hz RPW-SSD23 10075631 853,00

230VAC 50/60Hz RPW-SSD24 10583790 853,00

240VAC 50/60Hz RPW-SSD25 10583791 853,00

380VAC 50/60Hz RPW-SSD33 10075632 853,00

400VAC 50/60Hz RPW-SSD34 10583792 853,00

415VAC 50/60Hz RPW-SSD35 10583793 853,00

440VAC 50/60Hz RPW-SSD36 10075633 853,00

460VAC 50/60Hz RPW-SSD38 10583794 853,00

480VAC 50/60Hz RPW-SSD39 10075634 853,00

RPW - FF - PHASE LOSS PROTECTOR

RPW - FSF - PHASE LOSS AND PHASE SEQUENCE PROTECTOR

RPW - SF - PHASE SEQUENCE PROTECTOR

RPW - PTC - PTC PROTECTOR

RPW - SS - UNDER VOLTAGE AND OVERVOLTAGE PROTECTOR

Page 91: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

178 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 179

Electronic Level Control Relay - RNW

RATED VOLTAGE TYPE STOCK CODEPRICE EACH

(ZAR)

100-240VAC 50/60 Hz

100-240VDC RNW-ESE09 10318025 893,00

TYPE DESCRIPTION STOCK CODEPRICE EACH

(ZAR)

EPW PENDULUM ELECTRODE WEG 10583739 114,00

EHW SHAFT ELECTRODE WEG 10583740 622,00

PLMP 1) PUSH-IN-LUGS WEG 10185925 3,00

RATED VOLTAGE TYPE STOCK CODEPRICE EACH

(ZAR)

100-240 V AC 50/60 Hz

100-240VDCRNW-ENE09 10318026 893,00

ELECTRONIC LEVEL CONTROL RELAY - RNW

ACCESSORIES FOR ELECTRONIC LEVEL CONTROL RELAY

RNW ES - DRAINING

RNW EN - FILLING

Pendulum electrode Push-in-lugsShaft electrode

Note : 1) Quantity per packing: 2 units.

VERSATILITY

The SRW01 supports the following communication networks

protocols: DeviceNet, Modbus-RTU, and Profibus-DP.

The communication modules can be easily exchanged due to

its plug and play capabilities.

The SRW01 provides a USB port for relay monitoring,

programming and back-up on-line the parameters through

PC when using WLP software.

The SRW has a HMI that can be used for quick system

monitoring and relay parameterization. Additionally, the

internal memory allows the user to do the upload and

download of up to three parameters set and three user

programs.

The SRW01 includes a thermal memory circuit in order to

maintain a motor thermal image, even if power supply if is

removed.

FLEXIBILITY

The SRW01 has a modular design, providing easy

assembling and integration.

The Control Unit (UC) can be assembled with the Current

Measuring Unit (UMC) or current and voltage measuring unit

(SRW01-UMCT), forming a single unit, or separated (up to 2

meters).

The SRW01 has pre-programmed operation modes,

which operates in several kinds of starting and monitoring

modes. One of them is the transparent mode that can be

programmed according to your needs, making the SRW01 fit

to the most diverse applications.

The digital input and output functions of the Control Unit (UC)

are automatically configured as the operation mode is

selected, defining in an easy and simple way the connection

between the control circuit and the SRW01 in the starter.

The digital inputs can be configured to monitor external

digital signals using the external fault funciton. With this

feature the user can connect the output contact from an

external relay to the digital input of the SRW01 relay. Thus the

relay SRW01 makes possible the user to use various

protections for a motor in a same relay, as earth leakage and

thermal like PTC.

* The current and voltage measuring unit (UMCT) only allows separate

assembly of the Control Unit (UC).

Smart Relay

SRW01

The SRW01 is a low-voltage electric motor management system with state-of-the-art technology and

network communication capabilities. Additionally, its modular concept allows the expansion of its

funcionalities, Plug and Play philosophy, free WLP programming software and USB communication.

Page 92: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

180 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 181

Modular Design

The SRW01 incorporates a main Control Unit SRW01-UC and

a Current Measuring Unit (SRW01-UMC) or a current and

voltage measuring unit (SRW01-UMCT) that are electrically

connected using a flat cable SRW01-CB.

The relay allows to add digital inputs and outputs through the

digital expansion module.

This management system is a modular design, providing more

flexibility in the design, project and assembly the motor starter.

The interface with the relay may be performed in three ways:

Via Fieldbus (Modbus, DeviceNet, Profibus)

Via SRW01-HMI

Via software - WLP (USB)

Through Fieldbus, the user can operate, monitor and

configure the SRW01 remotely, via PLC or supervisory

system.

The HMI is connected to SRW01 through cable connection

that can be programmed, operated and monitored in a

use-friendly way.

The interaction can be done via software through a shielded

USB cable or via Modbus network, through the WLP.

med in three ways: Through Fieldbus the user c

Modular Design

Reduced size, compact structure

Control Unit (UC) input power range: 110-240 V ac/dc or 24 V ac/dc

Control Unit (UC) with 4 digital inputs and 4 digital outputs

DIN rail or screws mounting

Easy network module change, via exclusive drawer system

Programming via free WLP software or HMI (optional)

The SRW01-UC Control Unit provides LED indicators

for input and output activations, status, operation

mode, power supply status, failure and alarm status.

The mounting of the Control Unit can be done either by

35 mm DIN rail or onto back panel mounting.

Communication protocols: DeviceNet, Modbus, and

Profibus are defined using proper protocol installed in

the communication drawer.

The Plug and Play concept automatically recognizes

and configures the SRW01 for safe operation, avoiding

manual error configuration.

CHARACTERISTICS

Profibus - DP network connection

Modbus, DeviceNet

or Profibus - DP connection

Mini USB port

Led indicator for digital output

Connection for EDU and IHM

Communication module

Reset

PTC or ground leakage sensor input

Led indicator for digital input

Page 93: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

182 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 183

Configuration assistant

Monitoring diagnosis

Provides the option of increasing the number of digital inputs and outputs.

It has 6 digital inputs and 4 digital outputs, totalizing 10 digital inputs and 8

digital outputs, with the inputs and outputs of the Control Unit (UC).

It can be used to transfer information, alarm signalling or external devices

state.*Maximum of 1 digital expansion unit (EDU) for 1 Control Unit (UC).

The Current Measuring Unit (UMC) measures the current of the three

motor phases.

Using a current and voltage measuring unit (UMCT), in addition to

measuring the motor currents (as in the UMC), it is also possible to monitor

voltages up to 690 V ac, phase sequence, power factor, all the motor

powers and make management and electric power consumption (kW/h).

The values are digitally transmitted to the Control Unit (UC).

SRW01 parametrization, programming, command and monitoring

Configures, edits the parameters and programs in “Ladder” language

with mathematical and control blocks

Configuration assistant

USB or Modbus network communication

DIGITAL EXPANSION UNIT (EDU)

CURRENT MEASURING UNIT (UMC) OR CURRENT AND VOLTAGE MEASURING UNIT (UMCT)

FREE PROGRAMMING SOFTWARE - WLP (WEG LADDER PROGRAMMER)

Modular Design

UMC UMCT

The SRW01 protection, monitoring and operating functions enhance system protection reliability and precision. The operating

modes are auto-adjustable, meaning that the user selects the operating mode and the relay search for proper parameters

automatically. This feature ensures quick and safe parameterization. All operating modes allow motor monitoring. Its friendly

parameterization mode allows users to access all digital inputs and outputs, thus increasing flexibility to cover many applications.

PROTECTION

Overload protection (adjustable tripping class 5-45)

Thermal protection via PTC

Phase loss protection

Protection against current unbalance between phases

Protection against overcurrent and locked rotor

Protection against undercurrent

Internal ground fault protection

Protection against out of range frequency

Earth leakage

External fault

Phase sequence*

Voltage unbalance*

Phase loss (voltage)*

Over and undervoltage*

Over and underpower*

Over and under power factor*

Management consumption kWh and kVArh*

OPERATING MODES

Transparent operation - digital input and output can be

configured according to application needs. In this operation

mode the UMC/UMCT is used

Operation as overload relay - similar to an overload relay

Direct starter - direct-on-line starter for single and three-

phase motors

Reversing starter - reversing starter for three-phase motors

Star-Delta starter - star-delta starter switch for three-phase

motors

Dahlander starter- starter for Dahlander three-phase

motors

Two windings starter - starter for two windings three-phase

motors

PLC mode - similar to the running of a PLC

In this operation mode the UMC/UMCT is not used

MONITORING

Digital input and output activation

RMS current of each phase and average in amperes

or % of In adjusted current

Line and average voltage (V)

Motor frequency

Number of activation per failute type

Number of start ups

Motor running hours

Relay running hours

Phase unbalance levels

Internal ground fault level

Earth leakage current

Power factor*

Consumption*

Active, reactive and apparent power*

PTC value

WLP Software free

USB port to connect the relay with the computer

Back-up the relay configuration using the software WLP

Downtime reduction

Power factor monitoring and consumption, via current and voltage measuring unit (UMCT)

Higher reliability in the motor protection system

Safety during the operation, monitoring and maintenance

Modularity and easy system expansion

Reduction of the control wiring

Reduced hardware responsible for motor control

Remote reset via fieldbus network

Quick and accuracy in identifying failures or alarms

Automatic defect records and statistics

Monitoring, supervision and control via fieldbus network, computer (WLP) or human-machine interface

Benefits

Functions

* Available only using UMCT

Page 94: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

184 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 185

Applications

The main function of the SRW01 is to protect and control

electric motors in their most diverse industrial applications.

Due to its reduced size and modular design, the relay is

frequently used when space for its assembly is a determining

point, e.g. in Intelligent Motor Control Centers.

Its high reliability and precision make the

SRW01 suitable for the toughest

industrial applications.

The on-line monitoring options, failure

diagnosis and failure statistics allow

preventive maintenance to be more

effective, thus reducing the number of

downtimes.

It offers wide application for continuous

process plants in the following market

segments:

Chemical and Petrochemical

Pulp and Paper

Mining and Cement

Food and Beverage

Metal and Fabrication

Plastics and rubber

Automotive

Ceramics

Textile

Refrigeration

Other segments

Selection Guide

UC - CONTROL UNIT

Reference Protection Supply voltage Communication protocol Digital input voltage

SRW01-UC-BE1E47 Earth leakage 110-240 V ac (50-60 Hz) / V dc

Without communication

24 V dc

SRW01-UC-BE1E26 Earth leakage 24 V ac (50-60 Hz) / V dc 24 V dc

SRW01-UC-BE2E47 Earth leakage 110-240 V ac (50-60 Hz) / V dc 110 V ac

SRW01-UC-BE2E26 Earth leakage 24 V ac (50-60 Hz) / V dc 110 V ac

SRW01-UC-BT1E47 PTC 110-240 V ac (50-60 Hz) / V dc 24 V dc

SRW01-UC-BT1E26 PTC 24 V ac (50-60 Hz) / V dc 24 V dc

SRW01-UC-BT2E47 PTC 110-240 V ac (50-60 Hz) / V dc 110 V ac

SRW01-UC-BT2E26 PTC 24 V ac (50-60 Hz) / V dc 110 V ac

SRW01-UC-DE1E47 Earth leakage 110-240 V ac (50-60 Hz) / V dc

DeviceNet

24 V dc

SRW01-UC-DE1E26 Earth leakage 24 V ac (50-60 Hz) / V dc 24 V dc

SRW01-UC-DE2E47 Earth leakage 110-240 V ac (50-60 Hz) / V dc 110 V ac

SRW01-UC-DE2E26 Earth leakage 24 V ac (50-60 Hz) / V dc 110 V ac

SRW01-UC-DT1E47 PTC 110-240 V ac (50-60 Hz) / V dc 24 V dc

SRW01-UC-DT1E26 PTC 24 V ac (50-60 Hz) / V dc 24 V dc

SRW01-UC-DT2E47 PTC 110-240 V ac (50-60 Hz) / V dc 110 V ac

SRW01-UC-DT2E26 PTC 24 V ac (50-60 Hz) / V dc 110 V ac

SRW01-UC-PE1E47 Earth leakage 110-240 V ac (50-60 Hz) / V dc

Profibus-DP

24 V dc

SRW01-UC-PE1E26 Earth leakage 24 V ac (50-60 Hz) / V dc 24 V dc

SRW01-UC-PE2E47 Earth leakage 110-240 V ac (50-60 Hz) / V dc 110 V ac

SRW01-UC-PE2E26 Earth leakage 24 V ac (50-60 Hz) / V dc 110 V ac

SRW01-UC-PT1E47 PTC 110-240 V ac (50-60 Hz) / V dc 24 V dc

SRW01-UC-PT1E26 PTC 24 V ac (50-60 Hz) / V dc 24 V dc

SRW01-UC-PT2E47 PTC 110-240 V ac (50-60 Hz) / V dc 110 V ac

SRW01-UC-PT2E26 PTC 24 V ac (50-60 Hz) / V dc 110 V ac

SRW01-UC-ME1E47 Earth leakage 110-240 V ac (50-60 Hz) / V dc

Modbus

24 V dc

SRW01-UC-ME1E26 Earth leakage 24 V ac (50-60 Hz) / V dc 24 V dc

SRW01-UC-ME2E47 Earth leakage 110-240 V ac (50-60 Hz) / V dc 110 V ac

SRW01-UC-ME2E26 Earth leakage 24 V ac (50-60 Hz) / V dc 110 V ac

SRW01-UC-MT1E47 PTC 110-240 V ac (50-60 Hz) / V dc 24 V dc

SRW01-UC-MT1E26 PTC 24 V ac (50-60 Hz) / V dc 24 V dc

SRW01-UC-MT2E47 PTC 110-240 V ac (50-60 Hz) / V dc 110 V ac

SRW01-UC-MT2E26 PTC 24 V ac (50-60 Hz) / V dc 110 V ac

Communication protocol

B = Without communication

D = DeviceNet

M = Modbus

P = Profibus

SRW01-U C P T 1 E47

Protection

E - Earth leakage

T - PTC

Digital input operating voltage

1 = 24 V dc

2 = 110 V ac

Supply voltage

E26 - 24 V ac (50-60 Hz) / V dc

E47 - 110-240 V ac (50-60 Hz) / V dc

Page 95: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

186 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 187

WLP Software

The WLP is the SRW01 configuration software for Windows

environment with user friendly interface that enables system

parametrization, programming, controlling and monitoring.

The WLP software enables the user to configure the relay,

edit parameters and program in LADDER.

Through the WLP configuration assistants the user has a

guided routine that enables relay configuration. When

necessary, the relay can be programmed in LADDER using

mathematical and control blocks.

The LADDER program has a 64 kbytes memory and can use

the relay digital inputs and outputs.

Communication between software and relay can be

performed through USB port or Modbus network.

The WLP software is free and supplied with the product.

It can be also obtained from the website www.weg.net.

CONFIGURATION ASSISTANTS

These routines have been especially created to assist relay configuration. They help the user to configure the relay in an easy self

explanatory manner.

Configuration assistant: control configuration

MONITORING DIALOGUES

These dialogues have been especially created to monitor the relay.

They monitor exclusive relay information.

Monitoring dialogues: diagnostic

Technical Characteristics

Notes: 1) Consult the user’s manual;

2) Considering the Control Unit (UC) and Current Measuring Unit (UMC) or current/voltage measuring unit (UMCT) consumption.

General data

Mounting position Any

Pollution degree 2

Protection degree (IEC 60529)

- Control Unit (UC): IP20

- Current Measuring Unit (UMC):

- Without busbar: IP20

- With busbar: IP00

- Current and voltage measuring unit (UMCT):

- Without busbar: IP20

- With busbar: IP00

- Digital expansion unit (EDU): IP20

- Human machine interface (HMI): IP54

- Earth leakage sensor (ELS): IP20

Allowed ambient temperature

- Operation: According IEC: 0...+55 ºC

According UL: 0...+40 °C

- Storage and transport: -25...+80 °C

Short-circuit ratings (UL)1) Control Unit (UC): 200,000 A

Current Measuring Unit (UMC) and Current/voltage Measuring Unit (UMCT): 200,000 A

Tripping class (UL)- Control Unit (UC): classes 10/20/30

- Current Measuring Unit (UMC): classes 10/20/30

Control Unit (UC)

Isolation rated voltage Ui 300 V

Supply rated voltage 110 - 240 V ac/V dc @ 50/60 Hz 24 V ac/V dc @ 50/60 Hz

Operation range 0.85 Us - 1.10 Us 0.80 Us - 1.20 Us

Consumption (typical) 2) 6 W 5 W

Number of digital inputs 4 opticaly isolated inputs (24 V dc or 240 V ac)

Digital inputs supply 24 V dc 110 V ac

Digital inputs power sourceInternal 24 V dc isolated power source or

externalExternal 110 V ac power

Digital inputs current 11 mA @ 24 V dc 5 mA @ 110 V ac

Digital inputs isolation 3 kV

Number of digital outputs 4 relay outputs

Contacts grouping- 2 SPST outputs

- 2 common shared SPST outputs

Maximum operation voltage 250 V dc, 240 V ac

Smallest operation power 1 W or 1 VA

Switching capacity per relay contacts

- UL 508: C300, R300

- AC-15 (IEC 60947-5-1): 1.5 A ac / 120 V ac

0.75 A ac / 240 V ac

- DC-13 (IEC 60947-5-1): 0.22 A dc / 125 V dc

0.1 A dc / 250 V dc

Contacts capacity (resistive load) 3 A, 30 V dc / 250 V ac

External protection against short-circuit 6 A gL/gG fuse

Motor protection VIA - PTC- TRIP value: > 3.4 kΩ

- Rearm value: < 1.6 kΩ

Terminals (conectors)

- Torque: 0.5 Nm - 4.5 lb.in

- Conductors section:

- Rigid and bare: 1 x (0.2 ... 2.5 mm2); 1 x (2 ... 12 AWG)

- Flexible with/without terminals: 1x (0.2 ... 2.5 mm2); 1 x (26 ... 12 AWG)

- Screws: M3

Reset button

- Error or fault reset - system

- TRIP or alarm reset - protections

- TRIP test

Current Measuring Unit (UMC)

Current range 0.25 - 840 A ac

Isolation degree Ui

690 V ac

Rated operational voltage Ue

- IEC 60947-4-1: 690 V ac

- UL 508: 600 V ac

Impulse voltage Uimp

6 kV

Frequency range 50/60 Hz

Application Three-phase, single-phase

Cable hole diameter

- UMC 1, 2 and 3: 8 mm

- UMC 4: 15 mm

- UMC 5: busbar

- UMC 6: 32 mm or busbar

Page 96: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

188 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 189

Earth Leakage Sensor (ELS)

Current range 0.3 - 5 A ac

Isolation degree Ui

690 V ac

Rated operation voltage- IEC 60947-4-1: 690 V ac

- UL 508: 600 V ac

Impulse voltage Uimp

6 kV

Frequency range 50/60 Hz

Application Monophasic and triphasic

Window internal diameter

- EL1: 35 mm

- EL1: 70 mm

- EL1: 120 mm

- EL1: 210 mm

Terminals (conectors)

- Torque: 0.29 Nm - 2.6 lb.in

- Maximum conductos section:

- Rigid and bare: 1 x (0.2 ... 2.5 mm²); 1 x (22 ... 14 AWG)

- lexible with/without terminals: 1 x (0.2 ... 1.5 mm²); 1 x (22 ... 14 AWG)

- Screws: M3

Digital Expansion Unit (EDU)

Rated isolation voltage Ui

300 V

Number of digital inputs 6 optically isolated inputs (24 V dc or 110 V ac)

Digital inputs supply 24 V dc 110 V ac

Digital inputs power source External 24 V dc power source External 110 V ac power source

Digital inputs current 11 mA @ 24 V dc 5 mA @ 110 V ac

Digital inputs isolation 3 kV

Number of digital outputs 4 relay outputs

Contacts grouping 4 SPST outputs

Maximum operation voltage 250 V dc, 240 V ac

Smallest operation power 1 W or 1 VA

Switching capacity per relay contact

- UL 508: C300, R300

- AC-15 (IEC 60947-5-1): 1.5 A ac / 120 V ac

0.75 A ac / 240 V ac

- DC-13 (IEC 60947-5-1): 0.22 A dc / 125 V dc

0.1 A dc / 250 V dc

Contacts capacity (resistive load) 3 A, 30 V dc / 250 V ac

Short-circuit external capacity 6 A gl/gG fuse

Terminals (conectors)

- Torque: 0.5 Nm - 4.5 lb.in

- Conductors section:

-Rigid and bare: 1 x (0.2 ... 2.5 mm2); 1 x (26 ... 12 AWG)

-Flexible with/without terminals: 1 x (0.2 ... 2.5 mm2); 1 x (26 ... 12 AWG)

- Screws: M3

Current and Voltage Measuring Unit

(UMCT)

Current range 0.25 - 840 A ac

Voltage range 35 - 690 V ac

Isolation degree Ui

690 V ac

Rated operational voltage - Ue

IEC 60947-4-1: 690 V ac

UL 508: 600 V ac

Impulse voltage Uimp

6 kV

Frequency range 50/60 Hz

Application Three-phase, single-phase

Cable hole diameter

UMCT 1, 2 and 3: 8 mm

UMCT 4: 15 mm

UMCT 5: busbar

UMCT 6: 32 mm or busbar

Terminals (connectors)

- Torque tightening: 0.5 Nm - 4.5 lb.in

- Maximum conductos section:

- Rigid and bare: 1 x (0.2 ... 2.5 mm2); 1 x (26 ... 12 AWG)

- Flexible with/without terminals: 1 x (0.2 ... 2.5 mm2); 1 x (26 ... 12 AWG)

- Screws: M3

Operating Modes Diagrams

POWER CABLES

CONNECTION OF THE CONTROL UNIT TO THE EXPANSION DIGITAL UNIT

Three-phase and single-phase of the Current Measuring Unit (UMC) and Current/Voltage Measuring Unit (UMCT).

Connection diagrams of the Control Unit (UC) with the Digital Expansion Unit (EDU).

Q1

SRW01-CB

SRW01-UC

S1

A2 C1

k1 k2

O1 O2 C3 O3 C4 O4

S2

S0 S1 S2 K1 K2

Q1

RL1

110 ... 240 V AC/V DC 50/60 Hz

N

L1 L2 L3 L4 LC A1

SRW01-CB

SRW01-EDU

PE

C5 O5 C6 O6 C7 O7 C8 O8

L5 L6 L7 L8 L9 L10 BC

S2

K1

1

2

3

4

5

6

1

2

3

4

5

6

M

W2 W1

V2 V1

V1V2

3

K2

R/L1

S/L2

T/L3

> > >

>

Q2

>

S2 S2 S2 S2 S224 V CC

R/L1 RL1110 ... 240 V ac/V dc 50/60 Hz

NS/L2

T/L3

Q1

SRW01-CB

SRW01-UC

S1

S0 S1 S2S2 S2 S2 S2 S2 S2

24 V dc

Q2

K1 K2

Q1

S2 I1 I2 I3 I4 IC A1 PE

C5 O5 C6 O6 C7 O7 C8 O8

I5 I6 I7 I8 I9 I10 EC

SRW01-EDU

A2

K1 K2

C1 O1 O2 C3 O3 O4C4

SRW01-CB

K1 K21

W2

V2

V2 V1

W1

V1

1

2 2

3 3

4 4

5 5

6 6

M3

K1

L1 L2 L3

T1 T2 T3

M3

SRW01-UMC

3

K1

L1 L2 L3

T1 T2 T3

M1

SRW01-UMC

1 1

M1

K1

L1

N L

L2 L3 L1 L2 L3

T1 T2 T3 SRW01-UMCT

K1

L1 L2 L3 L1 L2 L3

T1 T2 T3

M3

SRW01-UMCT

33

K1 K1 K1 K1

L1 L1

T1 T1 T1

1 1

L3

T1 T2 T2 T2 T2T3 T3 T3 T3SRW01-UMC SRW01-UMCT

SRW01-UMC SRW01-UMCT

L2 L2L3 L1 L1 L1 L1L2 L2 L2 L2L3 L3 L3 L3

31

N N

1

M M M M

3 3 1 1

Page 97: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

190 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 191

DIRECT STARTER

Connection diagram for the Reverter Starting Operation Mode using digital inputs at 24 V dc and driven by pushbuttons (P230 = 1).

For further information consult the SRW-01 User’s Manual.

REVERSING STARTER

Connection diagrams for the Direct Starting Operation Mode using digital inputs at 24 V dc and driven by pushbuttons (P230 = 1).

For further information consult the SRW-01 User’s Manual.

R/L1

S/L2

T/L3

Q1

K1

1

L1

SRW01-UMCSRW01-CB

SRW01-UC

S1

S1

K1

SO

R/L1

110 ... 240 V ac/V dc 50/60 Hz

Q1 Q2

N

S1 K1

C1 01

S2 I1 I2 I3 I4 IC A1

T1

U V W

M3

T2 T3

L2 L3

2 4 6

3 5

02 C3 03 C4 O4

R/L1

S/L2

T/L3

Q1

K1

SRW01-UMCSRW01-CB

SRW01-UC

110 ... 240 V ac/V dc 50/60 Hz

R/L1

N

Q1

S0

S1

A2

S2

C1

K1 K2

I1

O1

I2

O2

I3

C3

I4

O3

IC

C4

A1

O4

S1 S2 K1 K2

Q2

L1

T1

U V W

M3

L2

T2

L3

T3

K2

1 1

2 2

3 35 5

4 46 6

OVERLOAD RELAY

Connection diagram for the Overload Relay operation mode using digital inputs at 24 V dc.For further information consult the SRW-01 User’s Manual.

TWO WINDINGS STARTER

Connection diagram for the Two Windings Starting Operation Mode using digital inputs at 24 V dc and driven by pushbuttons (P230=1).

For further information consult the SRW-01 User’s Manual.

R/L1

S/L2

T/L3

Q1

K1

SRW01-UMCSRW01-CB

SRW01-UC

R/L1

110 ... 240 V ac/V dc 50/60 Hz

Q1

S0

S1 S2 I1 I2 I3 I4 IC A1

S1 S2 S3

Q2

N

L1

U V W

M

3

L2 L3

1

2

3

4

5

6

A2 C1 O1

A2

A1K1

O2 C3 O3 C4 O4

110 ... 240 V ac/V dc 50/60 Hz

R/L1 R/L1

N

Q1

S0

S1 S2 I1 I2 I3 I4 IC A1

S1 S2 K1 K2

Q1

S/L2

T/L3

Q1

SRW01-UMC

L1

T1

L2

T2

L3

T3

K1 K2

1 1

2 2

3 3

4 4

5 5

6 6

SRW01-CB

SRW01-UC

W2

V2

V2

V1

V1

M

W1

3

A2 C1

K1 K2

O1 O2 C3 O3 C4 O4

Page 98: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

192 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 193

SRW01-CB CONNECTION CABLE

The cable SRW01-CB is responsable for the electric connection of the Control Unit SRW01-UC with the UMC or UMCT or EDU,

make capable the assembly detached until 2 meters and facilitate the installation.

For applications in higher currents, or that are out ot the UMC’s or UMCT’s range showed above, it is possible to use external current transformers (CT),

supplied by the user.

Accessories

CURRENT MEASURING UNIT (UMC) OR CURRENT AND VOLTAGE MEASURING UNIT (UMCT)

Shall be chosen according to motor rated current.

Width (mm) Current (A) Power connection

45

0.25 - 2.5 2)

Cable through UMC0.5 - 5

1.25 - 12.5

2.5 - 25

Width (mm) Current (A) Power connection

66 12.5 - 125 Cable through UMC

Width (mm) Current (A) Power connection

120 42 - 420 Busbar

Width (mm) Current (A) Power connection

265 84 - 840 Cable through or busbar

Current range (A) Current Measuring (UMC) Current and Voltage Measuring (UMCT) 1)

0.5-5 SRW01-UMC1 SRW01-UMCT1

1.25-12.5 SRW01-UMC2 SRW01-UMCT2

2.5-25 SRW01-UMC3 SRW01-UMCT3

12.5-125 SRW01-UMC4 SRW01-UMCT4

42-420 SRW01-UMC5 SRW01-UMCT5

84-840 SRW01-UMC6 SRW01-UMCT6

1) Alternating Voltage Range from 35 to 690 V .

Note: the Control Unit (UC) can be assembled with the Currente Measuring Unit (UMC), creating a unique unit, or detached (until 2 meters). The Current and

Voltage Measuring Unit (UMCT) exclusively can assembled detached with the Control Unit.

2) For current range 0.25 to 2.5 A use SRW01-UMC1 or SRW-UMCT1 with two windings on the primary.

For further information, verify the User´s Manual.

Notes: 1) Cable for connect the Control Unit with the EDU.

2) Minimum cable for connect the Control Unit with the UMC/UMCT 1, 2, 3 and 4.

3) Minimum cable for connect the Control Unit with the UMC/UMCT 5 and 6.

SRW01-UMC1, 2 and 3

SRW01-UMC4 SRW01-UMCT4

SRW01-UMC5 SRW01-UMCT5

SRW01-UMCT6SRW01-UMC6

SRW01-UMCT1, 2 and 3

Reference Length (mm)

SRW01-CB0 1) 60

SRW01-CB1 2) 120

SRW01-CB2 3) 500

SRW01-CB3 2000

SRW01-CB4 1000

Reference Digital inputs External digital input supply voltage Digital outputs

SRW01-EDU1 6 24 V dc 4

SRW01-EDU2 6 110 V ac 4

Reference Description

SRW01-HMI Human machine interface - HMI

DIGITAL EXPANSION UNIT - EDU

HUMAN MACHINE INTERFACE - HMI

EARTH LEAKAGE SENSOR (ELS)

The earth leakage sensor must be installed separately from the Control Unit (UC).

It can be installed in any position and connected on the Control Unit (UC) through a twisted pair and/or shielded cable, connected to

the sensor and S1 and S2 terminals, with maximum recommended distance of 10 m.

It is recomended to use the equivalence relation between the Current Measuring Unit (UMC) or current and voltage measuring unit

(UMCT) and the ELS sensors for the instalation, as shown on the table above.

The digital expansion unit is used to add six digital inputs and four digital outputs in the Control Unit with the purpose of the control

systems that has more variables.

Reference Description

SRW01-HMI2 Human machine interface - HMI (horizontal installation)

The HMI is connected in front of the relay through a communication cable, making configuration and operation practical and easier.

Reference Diameter (mm) UMC/UMCT compatible

SRW01-EL1 35 SRW01-UMC/UMCT 1, 2, 3

SRW01-EL2 70 SRW01-UMC/UMCT 4

SRW01-EL3 120 SRW01-UMC/UMCT 5

SRW01-EL4 210 SRW01-UMC/UMCT 6

Page 99: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

194 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 195

Reference Length (mm)

SRW01-USB 2000

Reference Description

JBL-RW407D Busbar for Current Measuring Unit UMC6 and UMCT6

Reference Communication protocol

SRW01-MCD DeviceNet

SRW01-MCM Modbus

SRW01-MCP Profibus-DP

For part replacement or Control Unit (UC) without network module.

USB COMMUNICATION CABLE

COMMUNICATION MODULE

BUSBAR FOR UMC AND UMCT

PROTECTION COVER

FIXING ADAPTOR

Notes: 1) 10 unit package;

2) Plastic cover for old housing model (not the current rubber cover).

The protection covers are for spare part purpose, because the SRW01 is already delivered

with these accessories.

Connector

IHM

Mini USBDB9

Reference Description

SRW01-CDB 1) Plastic cover for DB9 protection

SRW01-CMU 1) Plastic cover for mini USB connector

SRW01-CBP 1) 2) Plastic cover for HMI connector / accessories

CONNECTION CABLE UC-HMI

Reference Length (mm)

SRW01-CH1 500

SRW01-CH2 1000

SRW01-CH3 1500

SRW01-CH4 2000

Reference Description

PLMP Adaptor for screws fixing (2 pieces per package/0.006 kg)

Smart Relay

SMART RELAY WEG - SRW01

CONTROL UNIT - UC

TYPE FUNCTION S1 - S2 RATED VOLTAGE (V)COMUNICATION

PROTOCOLINPUT RATED VOLTAGE (V) STOCK CODE

PRICE EACH

(ZAR)

SRW01-UCBE1E47 Earth leakage 100-240 V 50/60 Hz-DC

Not available

24 V dc/cc 11072584 6776,00

SRW01-UCBE1E26 Earth leakage 24 V 50/60 Hz-DC 24 V dc/cc 11364681 7590,00

SRW01-UCBE2E47 Earth leakage 100-240 V 50/60 Hz-DC 110 V ac/ca 11072586 6776,00

SRW01-UCBE2E26 Earth leakage 24 V 50/60 Hz-DC 110 V ac/ca 11364680 7590,00

SRW01-UCBT1E47 PTC 100-240 V 50/60 Hz-DC 24 V dc/cc 10558177 6166,00

SRW01-UCBT1E26 PTC 24 V 50/60 Hz-DC 24 V dc/cc 11364685 6902,00

SRW01-UCBT2E47 PTC 100-240 V 50/60 Hz-DC 110 V ac/ca 10673330 6166,00

SRW01-UCBT2E26 PTC 24 V 50/60 Hz-DC 110 V ac/ca 11364684 6902,00

SRW01-UCPE1E47 Earth leakage 100-240 V 50/60 Hz-DC

Profibus

24 V dc/cc 11072136 9186,00

SRW01-UCPE1E26 Earth leakage 24 V 50/60 Hz-DC 24 V dc/cc 11364664 10297,00

SRW01-UCPE2E47 Earth leakage 100-240 V 50/60 Hz-DC 110 V ac/ca 11072137 9186,00

SRW01-UCPE2E26 Earth leakage 24 V 50/60 Hz-DC 110 V ac/ca 11364663 10297,00

SRW01-UCPT1E47 PTC 100-240 V 50/60 Hz-DC 24 V dc/cc 10673417 8560,00

SRW01-UCPT1E26 PTC 24 V 50/60 Hz-DC 24 V dc/cc 11364658 9593,00

SRW01-UCPT2E47 PTC 100-240 V 50/60 Hz-DC 110 V ac/ca 10673414 8560,00

SRW01-UCPT2E26 PTC 24 V 50/60 Hz-DC 110 V ac/ca 11364617 9593,00

SRW01-UCME1E47 Earth leakage 100-240 V 50/60 Hz-DC

Modbus

24 V dc/cc 11072133 8482,00

SRW01-UCME1E26 Earth leakage 24 V 50/60 Hz-DC 24 V dc/cc 11364666 9499,00

SRW01-UCME2E47 Earth leakage 100-240 V 50/60 Hz-DC 110 V ac/ca 11072135 8482,00

SRW01-UCME2E26 Earth leakage 24 V 50/60 Hz-DC 110 V ac/ca 11364665 9499,00

SRW01-UCMT1E47 PTC 100-240 V 50/60 Hz-DC 24 V dc/cc 10675557 7872,00

SRW01-UCMT1E26 PTC 24 V 50/60 Hz-DC 24 V dc/cc 11364683 8811,00

SRW01-UCMT2E47 PTC 100-240 V 50/60 Hz-DC 110 V ac/ca 10673440 7872,00

SRW01-UCMT1E26 PTC 24 V 50/60 Hz-DC 110 V ac/ca 11364682 8811,00

SRW01-UCDE1E47 Earth leakage 100-240 V 50/60 Hz-DC

DeviceNet

24 V dc/cc 11072131 7574,00

SRW01-UCDE1E26 Earth leakage 24 V 50/60 Hz-DC 24 V dc/cc 11364678 8482,00

SRW01-UCDE2E47 Earth leakage 100-240 V 50/60 Hz-DC 110 V ac/ca 11072132 7574,00

SRW01-UCDE2E26 Earth leakage 24 V 50/60 Hz-DC 110 V ac/ca 11364667 8482,00

SRW01-UCDT1E47 PTC 100-240 V 50/60 Hz-DC 24 V dc/cc 10673500 6964,00

SRW01-UCDT1E26 PTC 24 V 50/60 Hz-DC 24 V dc/cc 11364632 7809,00

SRW01-UCDT2E47 PTC 100-240 V 50/60 Hz-DC 110 V ac/ca 10673498 6964,00

SRW01-UCDT2E26 PTC 24 V 50/60 Hz-DC 110 V ac/ca 11364688 7809,00

Page 100: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

196 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 197

I/O EXPANSION MODULE - EDU

CURRENT MEASURE UNIT - UMC

CURRENT AND VOLTAGE MEASURE UNIT - UMCT

TYPE DIGITAL INPUTS DIGITAL OUTPUTSRATED VOLTAGE (V)

- EXTERNALSTOCK CODE

PRICE EACH

(ZAR)

SRW01-EDU1 6 4 24 V dc/cc 11367104 3391,00

SRW01-EDU2 6 4 110 V ac/ca 11367106 3391,00

TYPE CURRENT RANGE (A) STOCK CODEPRICE EACH

(ZAR)

SRW01-UMC1 0.5...5 10558179 2583,00

SRW01-UMC2 1.25...12.5 10558180 2645,00

SRW01-UMC3 2.5...25 10558181 2755,00

SRW01-UMC4 12.5...125 10558182 4038,00

SRW01-UMC5 42...420 10561132 5509,00

SRW01-UMC6 84...840 10561133 7387,00

TYPE CURRENT RANGE (A) VOLTAGE RANGE (VAC) STOCK CODEPRICE EACH

(ZAR)

SRW01-UMCT1 0.5...5 35...690 VAC 11751275 5938,00

SRW01-UMCT2 1.25...12.5 35...690 VAC 11751274 6010,00

SRW01-UMCT3 2.5...25 35...690 VAC 11751276 6135,00

SRW01-UMCT4 12.5...125 35...690 VAC 11739009 7601,00

SRW01-UMCT5 42...420 35...690 VAC 11751277 9282,00

SRW01-UMCT6 84...840 35...690 VAC 11751328 11429,00

Smart Relay - Accessories

ACCESSORIES

Smart Relay - Accessories

ACCESSORIES

UC-UMC OR UC-EDU CONNECTION CABLE

USB CONNECTION CABLE

EXTENSION CABLE IHM

UC-IHM CONNECTION CABLE

HUMAN MACHINE INTERFACE

TYPE LENGTH (mm) STOCK CODEPRICE EACH

(ZAR)

SRW01-CB0 60 11332922 103,00

SRW01-CB1 120 10558183 103,00

SRW01-CB2 500 10938235 120,00

SRW01-CB3 2000 10558185 138,00

SRW01-CB4 1000 11332919 138,00

TYPE LENGTH (mm) STOCK CODEPRICE EACH

(ZAR)

SRW01-CH1 500 10558187 258,00

SRW01-CH2 1000 10558188 275,00

SRW01-CH3 1500 10558189 275,00

SRW01-CH4 2000 11332397 343,00

TYPE DESCRIPTION STOCK CODEPRICE EACH

(ZAR)

SRW01-HMI HUMAN MACHINE INTERFACE (VERTICAL) 10558186 1988,00

SRW01-HMI2 HUMAN MACHINE INTERFACE (HORIZONTAL) 11578238 3668,00

TYPE LENGTH (mm) STOCK CODEPRICE EACH

(ZAR)

SRW01-USB 2000 10561134 309,00

TYPE LENGTH (mm) STOCK CODEPRICE EACH

(ZAR)

COM CABLE 1500 10624678 258,00

Page 101: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

198 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 199

COMMUNICATION MODULE

TYPE COMMUNICATION PROTOCOL STOCK CODEPRICE EACH

(ZAR)

SRW01-MCD DeviceNet 10575286 799,00

SRW01-MCM Modbus 10675582 1706,00

SRW01-MCP Profibus 10675585 2410,00

PUSH-IN-LUGS

EARTH LEAKAGE OR RESIDUAL CURRENT SENSOR

PROTECTION COVERS

BUSBAR FOR UMC

TYPE DESCRIPTION STOCK CODEPRICE EACH

(ZAR)

PLMP Push-in-lugs 10185925 3,00

TYPE DESCRIPTION STOCK CODEPRICE EACH

(ZAR)

JBL RW407D Busbar for UMC 10045718 2722,00

TYPE DIAMETER (mm) ASSEMBLE ON STOCK CODEPRICE EACH

(ZAR)

SRW01-EL1 35 UMC1, UMC2, UMC3 10997169 1951,00

SRW01-EL2 70 UMC4 10997170 3394,00

SRW01-EL3 120 UMC5 10997173 6115,00

SRW01-EL4 210 UMC6 10997174 12394,00

TYPE DESCRIPTION STOCK CODEPRICE EACH

(ZAR)

SRW01-CDB 1) PROTECTION COVER SRW01 DB9 9 FEMALE PINS 11080360 54,00

SRW01-CMU 1) PROTECTION COVER SRW MINI-USB 11080361 72,00

SRW01-CBP 1) PROTECTION COVER SRW01 PIN BAR 10 VIAS 11080359 126,00

Note : 1) Quantity per packing: 10 units.

Smart Relay - Accessories

ACCESSORIES

Technical Data

ILLUMINATION BLOCKS WITH INTEGRATED LED

SPECIAL BLOCKS (ILLUMINATION, SOCKETS, VOLTAGE REDUCTION)

DECENTRALIZED CONTROL STATIONS

Applicable standards IEC 60947-5-1, UL 508

Operation voltage range 0.85...1.10 x Ue

Degree of protection IP20 according to IEC 60529

Energy consumption (V ac/dc) 10 mA

Rated impulse voltage Ui according to IEC 60947-1 2.5 kV

Ambient temperature allowed - 25 ºC...+70 ºC

Average lifespan 100,000 hours

Brightness

Red 70 mcd

Yellow 115 mcd

White 275 mcd

Blue 64 mcd

Green 150 mcd

Terminal capacity Minimum (1 x 0.5 mm2) and maximum (2 x 2.5 mm2)

Tightening torque 0.8 N.m

Applicable standards IEC 60947-5-1, UL 508

Degree of protection IP20 according to IEC 60529

Rated impulse voltage Ui according to IEC 60947-1 4 kV

Ambient temperature allowed - 25 ºC...+70 ºC

Terminal capacity Minimum (1 x 0.5 mm2) and maximum (2 x 2.5 mm2)

Tightening torque 0.8 N.m

Applicable standards IEC 60947-5-1, IEC 50102, IEC 60529, UL 508

Certifications CE

Degree of protection IP66 according to IEC 60529

Ambient temperature allowed -25 ºC...+70 ºC

Material Polycarbonate (cover and base)

Cover color Gray (RAL 7035) or Yellow (RAL 1003)

Base color Black (RAL 9005)

Cable entry holes ØM20 / PG 13.5 / 1/2" and ØM16 / 3/8"

Use in ambients External (UV rays) or internal

Page 102: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

200 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 201

Pushbuttons and Pilot Lights - CSW

PUSHBUTTONS - IP66

DESCRIPTION COLOUR LABEL TYPE STOCK CODEPRICE EACH

(ZAR)

Flush

White Without CSW-BF0 10046302 48,00

Red Without CSW-BF1 10410270 48,00

Green Without CSW-BF2 10410271 48,00

Yellow Without CSW-BF3 10410272 48,00

Blue Without CSW-BF4 10046303 48,00

Black Without CSW-BF5 10410273 48,00

Recessed

White Without CSW-BGA0 10118548 54,00

Red Without CSW-BGA1 10118551 54,00

Green Without CSW-BGA2 10118549 54,00

Yellow Without CSW-BGA3 10118550 54,00

Blue Without CSW-BGA4 10118552 54,00

Black Without CSW-BGA5 10118553 54,00

Extended

White Without CSW-BS0 1) 11951560 58,00

Red Without CSW-BS1 1) 11163275 58,00

Green Without CSW-BS2 1) 11163274 58,00

Yellow Without CSW-BS3 1) 11951525 58,00

Blue Without CSW-BS4 1) 11951558 58,00

Black Without CSW-BS5 1) 11951559 58,00

Mushroom 40 mm

White Without CSW-BC0 11369300 73,00

Red Without CSW-BC1 10410279 73,00

Green Without CSW-BC2 10046304 73,00

Yellow Without CSW-BC3 10076495 73,00

Blue Without CSW-BC4 11369299 73,00

Black Without CSW-BC5 10076569 73,00

Double

(IP40)

Green-red l / O CSW-BD 1) 10186330 112,00

Green-red START/STOP CSW-BD12SS 1) 11596147 112,00

Green-red Without CSW-BD12 1) 11597320 112,00

White-black l / O CSW-BD55IO 1) 11436030 112,00

White-black START/STOP CSW-BD05SS 1) 11596179 112,00

White-black Without CSW-BD05 1) 11597321 112,00

Black-black + / - CSW-BD55PN 1) 11414863 112,00

Black-black / CSW-BD55FR 1) 11596182 112,00

Note : 1) UL pending.

Pushbuttons and Pilot Lights - CSW

ILLUMINATED PUSH BUTTON - IP66

MUSHROOM WITH LATCH - IP66

DESCRIPTION COLOUR LABEL TYPE STOCK CODEPRICE EACH

(ZAR)

Flush

Red Without CSW-BFI1 10186385 83,00

Green Without CSW-BFI2 10046388 83,00

Yellow Without CSW-BFI3 10046389 83,00

Blue Without CSW-BFI4 10046593 83,00

Orange Without CSW-BFI6 11278798 72,00

White Without CSW-BFI0 10046390 83,00

Extended

Red Without CSW-BSI1 10046676 98,00

Green Without CSW-BSI2 10046677 98,00

Yellow Without CSW-BSI3 10046678 98,00

Blue Without CSW-BSI4 10046679 98,00

Orange Without CSW-BSI6 11278756 98,00

White Without CSW-BSI0 10046675 98,00

Mushroom

Red Without CSW-BCI1 10046823 123,00

Green Without CSW-BCI2 10046824 123,00

Yellow Without CSW-BCI3 10046825 123,00

Blue Without CSW-BCI4 10046826 123,00

Orange Without CSW-BCI6 11278800 123,00

White Without CSW-BCI0 10046822 123,00

DESCRIPTION COLOUR LABEL TYPE STOCK CODEPRICE EACH

(ZAR)

Mushroom 40 mm - turn to

release

Red Without CSW-BCT1 11689397 98,00

Green Without CSW-BCT2 11688990 98,00

Yellow Without CSW-BCT3 11689418 98,00

Blue Without CSW-BCT4 11688975 98,00

Orange Without CSW-BCT5 11625789 98,00

White Without CSW-BCT0 11688988 98,00

Mushroom 40 mm - key to

release

Red Without CSW-BCY1 11689423 343,00

Green Without CSW-BCY2 11689029 343,00

Yellow Without CSW-BCY3 11688994 343,00

Blue Without CSW-BCY4 11688995 343,00

Orange Without CSW-BCY5 11689028 343,00

White Without CSW-BCY0 11688996 343,00

Page 103: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

202 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 203

Pushbuttons and Pilot Lights - CSW

SELECTOR SWITCHES - IP66

SELECTOR SWITCHES WITH KEY- IP66

DESCRIPTION POSITIONS TYPE STOCK CODEPRICE EACH

(ZAR)

Knob

2 fixed (45º) CSW-CK2F45 10046305 86,00

2 fixed (90º) CSW-CK2F90 10046306 86,00

2 w/return (45º) CSW-CK2R45 10046307 86,00

2 w/return (90°) CSW-CK2R90 10186456 86,00

3 fixed CSW-CK3F45 10046308 86,00

3 w/return CSW-CK3R45 10046309 86,00

3 ret. left CSW-CK3RE45 10046591 86,00

3 fixed (ZB) CSW-CK3F45ZB 10735992 86,00

3 w/return (ZB) CSW-CK3R45ZB 10856961 86,00

3 ret. right CSW-CK3RD45 10187758 86,00

3 w/return (U) CSW-CK3R45U 10642288 86,00

3 fixed (U) CSW-CK3F45U 10642290 86,00

Lever

2 fixed (45º) CSW-CA2F45 10046310 99,00

2 fixed (90º) CSW-CA2F90 10046311 99,00

2 w/return (45º) CSW-CA2R45 10186331 99,00

2 w/return (90°) CSW-CA2R90 10046312 99,00

3 fixed CSW-CA3F45 10046313 99,00

3 w/return CSW-CA3R45 10046314 99,00

3 ret. left CSW-CA3RE45 10046315 99,00

3 fixed (zb) CSW-CA3F45ZB 10076659 99,00

3 w/return (ZB) CSW-CA3R45ZB 10642098 99,00

3 ret. right CSW-CA3RD45 10047502 99,00

3 w/return (U) CSW-CA3F45U 10642379 99,00

3 fixed (u) CSW-CA3R45U 10642297 99,00

DESCRIPTION KEY WITHDRAWAL POSITION TYPE STOCK CODEPRICE EACH

(ZAR)

2 fixed (45º) All CSW-CY2F45 10046406 544,00

2 w/return All CSW-CY2R45 10046407 544,00

3 fixed (E) All CSW-CY3F45 10046408 544,00

3 fixed (ZB) All CSW-CY3F45ZB 10046409 544,00

3 w/return All CSW-CY3R45 10046410 544,00

3 w/return (ZB) All CSW-CY3R45ZB 11849386 544,00

2 fixed (90º) All CSW-CY2F90 10117909 544,00

2 w/return All CSW-CY2R90 10877713 544,00

3 ret. left All CSW-CY3RE45 10638318 544,00

3 ret. right All CSW-CY3RD45 11094192 544,00

3 w/return (U) All CSW-CY3R45U 11849409 544,00

3 fixed (U) All CSW-CY3F45U 11849408 544,00

2 fixed (45º) Left CSW-CYE2F45 10649456 544,00

2 fixed (45º) Right CSW-CYD2F45 11862802 544,00

3 fixed (E) Left CSW-CYE3F45 12460948 544,00

3 fixed (E) Right CSW-CYD3F45 10075383 544,00

3 fixed (E) Center CSW-CYC3F45 10075806 544,00

2 fixed (90º) Right CSW-CYD2F90 11230485 544,00

2 fixed (90º) Left CSW-CYE2F90 11568410 544,00

3 ret. right Center CSW-CYC3RD45 11926976 544,00

3 ret. right Left CSW-CYE3RD45 12242613 544,00

Pushbuttons and Pilot Lights - CSW

ILLUMINATED SELECTOR SWITCHES - IP66

DESCRIPTION COLOUR TYPE STOCK CODEPRICE EACH

(ZAR)

2 Fixed positions

Red CSW-CKI2F901 10046391 195,00

Green CSW-CKI2F902 10046392 195,00

Yellow CSW-CKI2F903 10046393 195,00

Blue CSW-CKI2F904 10046394 195,00

Orange CSW-CKI2F906 11278802 195,00

White CSW-CKI2F900 10046395 195,00

3 Fixed positions

Red CSW-CKI3F451 10046396 195,00

Green CSW-CKI3F452 10046397 195,00

Yellow CSW-CKI3F453 10046398 195,00

Blue CSW-CKI3F454 10046399 195,00

Orange CSW-CKI3F456 11278803 195,00

White CSW-CKI3F450 10046400 195,00

3 Positions with return

Red CSW-CKI3R451 10046401 195,00

Green CSW-CKI3R452 10046402 195,00

Yellow CSW-CKI3R453 10046403 195,00

Blue CSW-CKI3R454 10046404 195,00

Orange CSW-CKI3R456 11278807 195,00

White CSW-CKI3R450 10046405 195,00

3 Positions with return from right

Red CSW-CKI3RD451 10639994 195,00

Green CSW-CKI3RD452 10642382 195,00

Yellow CSW-CKI3RD453 10642384 195,00

Blue CSW-CKI 3RD454 10642385 195,00

Orange CSW-CKI3RD456 11278804 195,00

White CSW-CKI 3RD450 10642386 195,00

3 Positions with return from left

Red CSW-CKI3RE451 10047503 195,00

Green CSW-CKI3RE452 10047504 195,00

Yellow CSW-CKI3RE453 10642387 195,00

Blue CSW-CKI3RE454 10642498 195,00

Orange CSW-CKI3RE456 11278805 195,00

White CSW-CKI3RE450 10642499 195,00

Page 104: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

204 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 205

EMERGENCY STOP PUSHBUTTON WITH LATCH - IP66

BES RANGE (IEC60947-5-5 & EN418)

BES RANGE (IEC60947-5-5 & EN418) WITH GREEN POSITION INDICATOR

BE RANGE

DESCRIPTION FUNCTION TYPE STOCK CODEPRICE EACH

(ZAR)

Pushbutton 42 mm Turn to release CSW-BESG 11007367 107,00

Pushbutton 42 mm Pull to release CSW-BESP 11007569 107,00

Pushbutton 42 mm Key to release CSW-BESY 11007554 373,00

DESCRIPTION FUNCTION TYPE STOCK CODEPRICE EACH

(ZAR)

Pushbutton 42 mm Turn to release CSW-BESGS 12036616 123,00

Pushbutton 42 mm Pull to release CSW-BESPS 12036614 123,00

Pushbutton 42 mm Key to release CSW-BESYS 12036617 389,00

DESCRIPTION FUNCTION TYPE STOCK CODEPRICE EACH

(ZAR)

Mushroom 40 mm Turn to release CSW-BEG 10410280 98,00

Mushroom 40 mm Key to release CSW-BEY 10186386 343,00

Pull to release

Turn to release

Turn to release

SIGNALLING

RESET PUSHBUTTON WITH SHAFT

DESCRIPTION COLOUR TYPE STOCK CODEPRICE EACH

(ZAR)

Diffused

IP66

Red CSW-SD1 10410274 50,00

Green CSW-SD2 10410275 50,00

Yellow CSW-SD3 10410276 50,00

Blue CSW-SD4 10410278 50,00

Orange CSW-SD6 11278801 50,00

White CSW-SD0 10410277 50,00

Diffused

IP42

Red CSW-SD1-IP42 10046950 45,00

Green CSW-SD2-IP42 10046951 45,00

Yellow CSW-SD3-IP42 10046952 45,00

Blue CSW-SD4-IP42 10046954 45,00

White CSW-SD0-IP42 10046953 45,00

DESCRIPTION SHAFT LENGTH TYPE STOCK CODEPRICE EACH

(ZAR)

Flush pushbuttonMin: 22.5 mm

Max: 250 mmCSW-BHF437 12607702 91,00

Pushbuttons and Pilot Lights - CSW

BLACK FLANGE AND ACCESSORIES

FLANGES

CONTACT BLOCKS

INTEGRATED LED BLOCK

DESCRIPTION PACKAGING (UM) TYPE STOCK CODEPRICE EACH

(ZAR)

Flange (3 Pos)5

AF3 10186334 22,00

Flange (5 Pos) AF5 10186335 43,00

DESCRIPTION PACKING (UM) TYPE STOCK CODEPRICE EACH

(ZAR)

Single (1NO)

10

BC10-CSW 10353877 33,00

Single (1NC) BC01-CSW 10410281 33,00

(1NO+1NC) BC11-CSW 10410282 55,00

Double (2NO) BC20-CSW 10186332 55,00

Double (2NC)

1

BC02-CSW 10187798 55,00

(1NO early make) BCA10-CSW 10046411 40,00

(1NC late brake) BCR01-CSW 10046412 40,00

Latch BR-3P-CSW 10046413 64,00

Self-monitoring (1NC) BCM01-CSW 11984250 105,00

Flange

3 positions

Single

Latch Self-monitoring

Double

Flange

5 positions

VOLTAGE COLOUR TYPE STOCK CODEPRICE EACH

(ZAR)

12 V ac/dc

Red CSW-BIDL-1E25 10046711 97,00

Green CSW-BIDL-2E25 10046712 97,00

Yellow CSW-BIDL3-E25 10046710 97,00

Blue CSW-BIDL4-E25 10046713 97,00

White CSW-BIDL0-E25 10046709 97,00

24 V ac/dc

Red CSW-BIDL1-E26 10186495 97,00

Green CSW-BIDL2-E26 10186496 97,00

Yellow CSW-BIDL3-E26 10046715 97,00

Blue CSW-BIDL4-E26 10046716 97,00

White CSW-BIDL0-E26 10046714 97,00

48 V ac/dc

Red CSW-BIDL1-E27 10046719 97,00

Green CSW-BIDL2-E27 10046720 97,00

Yellow CSW-BIDL3-E27 10046718 97,00

Blue CSW-BIDL4-E27 10046721 97,00

White CSW-BIDL0-E27 10046717 97,00

110-130 V ac

Red CSW-BIDL1-D61 10186499 97,00

Green CSW-BIDL2-D61 10186500 97,00

Yellow CSW-BIDL3-D61 10186498 97,00

Blue CSW-BIDL4-D61 10186501 97,00

White CSW-BIDL0-D61 10186497 97,00

220-240 V ac

Red CSW-BIDL1-D66 10186504 97,00

Green CSW-BIDL2-D66 10186505 97,00

Yellow CSW-BIDL3-D66 10186503 97,00

Blue CSW-BIDL4-D66 10186506 97,00

White CSW-BIDL0-D66 10186502 97,00

125 V dc

Red CSW-BIDL1-C13 10186544 97,00

Green CSW-BIDL2-C13 10186545 97,00

Yellow CSW-BIDL3-C13 10186546 97,00

Blue CSW-BIDL4-C13 10046821 97,00

White CSW-BIDL0-C13 10186543 97,00

Accessories for Pushbuttons and Pilot Lights - CSW

Page 105: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

206 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 207

BLOCK FOR LAMP

MISCELLANEOUS

INCANDESCENT LAMPS

TRANSFORMER BLOCK - BRT

DESCRIPTION PACKING (UN) TYPE STOCK CODEPRICE EACH

(ZAR)

Full voltage AC/DC 1

CSW-BID 10410283 34,00

Res + diode (230 V) CSW-BIRD-D66 1) 10186333 123,00

DESCRIPTION PACKING (UN) TYPE STOCK CODEPRICE EACH

(ZAR)

Lamp. extractor 1 ACEF 10046256 60,00

Neutral plate 10 APN 10045239 6,00

DESCRIPTION PACKING (UN) TYPE STOCK CODEPRICE EACH

(ZAR)

6 V ac/dc (Ba9s)

25

L6VI-E48-0,6W 10045241 51,00

12 V ac/dc (Ba9s) L12VI-E25-1,8W 10046387 51,00

24 V ac/dc (Ba9s) L24VI-E26-2W 10045243 51,00

48 V ac/dc (Ba9s) L48VI-E27-2W 10046462 51,00

60 V ac/dc (Ba9s) L60VI-E28-1,2W 10045244 51,00

130 V ac/dc (Ba9s) L130VI-E30-2W 10409537 51,00

220 V ac/dc - Neon (Ba9s) L220VI-E31-2W 10409538 51,00

BIDL SUPPLY VOLTAGE PACKING (UN) TYPE STOCK CODEPRICE EACH

(ZAR)

BIDL 125 VDC 220 V dc / V cc1

CSW-BRT2 10047125 63,00

BIDL 220-240 VAC 380-460 V ac / V ca CSW-BRT4 10074373 63,00

Full voltage

AC/DC

Resistor

+ Diode

Neutral plate

ACCESSORIES FOR FLANGES

Accessories for Pushbuttons and Pilot Lights - CSW

Notes : 1) Incandescent Lamp 120 V included.

ACCESSORIES FOR FLANGES

MISCELLANEOUS

PLATE HOLDER WITH INSCRIPTION PLATE

DESCRIPTION PACKING (UN) TYPE STOCK CODEPRICE EACH

(ZAR)

Reduct. ring (30 -> 22 mm) 5 AR30 10187807 29,00

E-stop pushbutton prot 1 APEG 10213180 55,00

DIN rail adaptator 1 DRA-CSW 12187332 75,00

SIZE PLATE COLOUR DESCRIPTIONS PACKING (UN) TYPE STOCK CODEPRICE EACH

(ZAR)

(30x50) Holder

(27x18) Plate

Red-black (single pushbutton)

5

APP30 10185880 42,00

Transparent (single pushbutton) APP30T 10185886 42,00

(34x83) Holder

(27x18) Plate

Red-black (double pushbutton) APP60 10643837 42,00

Transparent (double pushbutton) APP60T 10583832 42,00

PLATE HOLDER WITHOUT INSCRIPTION PLATE

OTHER PLATES

SHAFT TO RESET PUSHBUTTON

SIZE PACKING (UN) TYPE STOCK CODEPRICE EACH

(ZAR)

30x50 5

PP30 1) 11427388 34,00

34x83 PP60 1) 11427391 34,00

IDIOM PACKING (UN) TYPE STOCK CODEPRICE EACH

(ZAR)

Portuguese-english

5

APE 10045238 69,00

English APE-02-ENG 11315980 69,00

English-spanish APE-03-ENG-SPA 10077414 69,00

SHAFT LENGTH TYPE STOCK CODEPRICE EACH

(ZAR)

Min: 22.5 mm

Max: 250 mmSH250 12470467 25,00

Emergency plate

Accessories for Pushbuttons and Pilot Lights - CSW

Page 106: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

208 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 209

CONTROL STATIONS PBW

PBW LINE ACCESSORIES

CONTACT BLOCKS

INTEGRATED LED BLOCK

HOLES COVER COLOUR TYPE STOCK CODEPRICE EACH

(ZAR)

1 Yellow PBW-1Y 12204334 193,00

1 Gray PBW-1 12204335 193,00

2 Gray PBW-2 12204336 226,00

3 Gray PBW-3 12204337 260,00

4 Gray PBW-4 12204388 311,00

6 Gray PBW-6 12204389 448,00

DESCRIPTION PACKING (UNITS) TYPE STOCK CODEPRICE EACH

(ZAR)

Single (1NO) 1

BC10B-CSW 12174856 33,00

Single (1NC) BC01B-CSW 12174857 33,00

VOLTAGE COLOUR TYPE STOCK CODEPRICE EACH

(ZAR)

12 V ac/dc

White CSW-BIDLB-0E25 12195732 97,00

Red CSW-BIDLB-1E25 12195737 97,00

Green CSW-BIDLB-2E25 12195839 97,00

Yellow CSW-BIDLB-3E25 12195840 97,00

Blue CSW-BIDLB-4E25 12195842 97,00

24 V ac/dc

White CSW-BIDLB-0E26 12195847 97,00

Red CSW-BIDLB-1E26 12195918 97,00

Green CSW-BIDLB-2E26 12195919 97,00

Yellow CSW-BIDLB-3E26 12195920 97,00

Blue CSW-BIDLB-4E26 12195921 97,00

48 V ac/dc

White CSW-BIDLB-0E27 12195922 97,00

Red CSW-BIDLB-1E27 12195923 97,00

Green CSW-BIDLB-2E27 12195924 97,00

Yellow CSW-BIDLB-3E27 12195926 97,00

Blue CSW-BIDLB-4E27 12195948 97,00

110-130 V ac

White CSW-BIDLB-0D61 12195949 97,00

Red CSW-BIDLB-1D61 12195950 97,00

Green CSW-BIDLB-2D61 12195951 97,00

Yellow CSW-BIDLB-3D61 12195956 97,00

Blue CSW-BIDLB-4D61 12195957 97,00

220-240 V ac

White CSW-BIDLB-0D66 12196008 97,00

Red CSW-BIDLB-1D66 12196009 97,00

Green CSW-BIDLB-2D66 12196010 97,00

Yellow CSW-BIDLB-3D66 12196011 97,00

Blue CSW-BIDLB-4D66 12196012 97,00

125 V dc

White CSW-BIDLB-0C13 12196013 97,00

Red CSW-BIDLB-1C13 12196014 97,00

Green CSW-BIDLB-2C13 12196015 97,00

Yellow CSW-BIDLB-3C13 12196016 97,00

Blue CSW-BIDLB-4C13 12196017 97,00

Accessories for Pushbuttons and Pilot Lights - CSW

ACCESSORIES FOR FLANGES AND CONTROL STATIONS

PLATE WITHOUT TEXT

PUSHBUTTON PROTECTION

MISCELLANEOUS

CAPS FOR PUSHBUTTONS (COLOUR CHANGING)

CAPS TO PUSHBUTTONS FOR SIGNALLING WITH SPECIFIC SYMBOL FUNCTIONS

SIZE COLOUR DESCRIPTIONS PACKING (UN) TYPE STOCK CODEPRICE EACH

(ZAR)

27x18

Red-black single plate5

AP30 10045237 15,00

Transparent single plate AP30T 10045240 15,00

Set with 10 white plates 15 CAP30 12439346 45,00

DESCRIPTION PACKING (UN) TYPE STOCK CODEPRICE EACH

(ZAR)

For flush pushb

5

APBF 10185879 63,00

For double push APBD 10046217 119,00

For Pushb BFI & BSI APBI 10075605 74,00

DESCRIPTION PACKING (UN) TYPE STOCK CODEPRICE EACH

(ZAR)

Plug (round) 5 ATR 10185878 15,00

Locking ring toll 1 CPAW 1) 10185933 24,00

DESCRIPTION COLOUR PACKING (UN) TYPE STOCK CODEPRICE EACH

(ZAR)

Flush pushbutton

Black

5

ACB5 10045226 6,00

Red ACB1 10045227 6,00

Green ACB2 10045228 6,00

Yellow ACB3 10045229 6,00

Blue ACB4 10045230 6,00

White ACB0 10071881 6,00

Mushroom 40 mmRed ACBC1 10071882 19,00

Green ACBC2 10071883 19,00

DESCRIPTION CAP-SYMBOL COLOUR FUNCTION PACKING (UN) TYPE STOCK CODEPRICE EACH

(ZAR)

Flush push button

Red-white Stop

5

ACB1-30 10045231 10,00

Black-white Start ACB5-31 10045232 10,00

Black-white Rect motion ACB5-32 10045233 10,00

Black-white Rot. to right ACB5-33 10045234 10,00

Black-white Rot. to left ACB5-34 10045235 10,00

Black-white Feeder ACB5-35 10045236 10,00

AP30

For double

pushbutton

CAP30

For flush

pushbutton

Accessories for Pushbuttons and Pilot Lights - CSW

Page 107: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

210 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 211

ACCESSORIES FOR FLANGES AND CONTROL STATIONS

CAPS TO PUSHBUTTONS FOR SIGNALLING WITH SPECIFIC SYMBOL FUNCTIONS

DIFFUSED LENS FOR SIGNALLING

DESCRIPTION CAP-SYMBOL COLOUR FUNCTION PACKING (UN) TYPE STOCK CODEPRICE EACH

(ZAR)

Iluminated push button

Black-white Stop

5

ALB1-30 10211962 11,00

Black-white Start ALB1-31 10211963 11,00

Black-white Rect motion ALB1-32 10211964 11,00

Black-white Rot. to right ALB1-33 10211965 11,00

Black-white Rot. to left ALB1-34 10211966 11,00

Black-white Feeder ALB1-35 10211967 11,00

APPLICATION DESCRIPTION COLOUR PACKING(UN) TYPE STOCK CODEPRICE EACH

(ZAR)

For pilot lights Diffused

Red

5

ALSD1 10185881 7,00

Green ALSD2 10185882 7,00

Yellow ALSD3 10185883 7,00

Blue ALSD4 10185884 7,00

White ALSD0 10185885 7,00

Accessories for Pushbuttons and Pilot Lights - CSW

COMMON SETS - CSW SERIES

PUSHBUTTONS

SELECTOR SWITCHES

SIGNALLING

DESCRIPTION TYPE STOCK CODEPRICE EACH

(ZAR)

FLUSH PUSHBUTTONS ON (GREEN - 1NO) CSW-BF2-1 10046328 81,00

FLUSH PUSHBUTTONS ON (BLACK - 1NO) CSW-BF5-1 10046329 81,00

FLUSH PUSHBUTTONS OFF (RED - 1NC) CSW-BF1-01 10186363 81,00

MUSHROOM PUSHBUTTONS ON (GREEN - 1NO) CSW-BC2-1 10046330 106,00

MUSHROOM PUSHBUTTONS OFF (RED - 1NC) CSW-BC1-01 10046331 106,00

EMERGENCY STOP PUSHBUTTONS TURN TO RESET (1NC) CSW-BEG-01 10186364 #N/A

DOUBLE PUSHBUTTONS (ON-OFF) - (1NO+1NC) CSW-BD-1100000 10046332 178,00

DOUBLE PUSHBUTTONS (ON-OFF) WITH INTEGRATED LED BLOCK 120VAC RED (1NO+1NC) CSW-BD-1100000D61 10046333 275,00

DOUBLE PUSHBUTTONS (ON-OFF) WITH INTEGRATED LED BLOCK 220VAC RED (1NO+1NC) CSW-BD-1100000D66 10046334 275,00

DOUBLE PUSHBUTTONS (ON-OFF) WITH RES+ DIODE BLOCK 220VAC WITH LAMP (1NO+1NC) CSW-BD-1100000D66 10046335 301,00

DOUBLE PUSHBUTTONS (ON-OFF) WITH INTEGRATED LED BLOCK 130VDC RED (1NO+1NC) CSW-BD-1100000C13 10046336 275,00

DOUBLE PUSHBUTTONS (ON-OFF) WITH FULL VOLTAGE BLOCK 220VDC WITH NEON LAMP (1NO+1NC) CSW-BD-1100000E31 10046337 213,00

DESCRIPTION TYPE ARTICLE NR.PRICE EACH

(ZAR)

KNOB SELECTOR SWITCH 2 FIXED POSITIONS - ON-OFF (1NO) CSW-CK2F45-10000000 10046338 119,00

KNOB SELECTOR SWITCH 3 FIXED POSITIONS - ON-OFF (1NO+1NO) CSW-CK3F45-20000000 10046339 152,00

LEVER SELECTOR SWITCH 2 FIXED POSITIONS - ON-OFF (1NO) CSW-CA2F45-10000000 10046340 132,00

LEVER SELECTOR SWITCH 3 FIXED POSITIONS - ON-OFF (1NO+1NO) CSW-CA3F45-20000000 10046341 165,00

DESCRIPTION TYPE ARTICLE NR. PRICE EACH

(ZAR)

DIFFUSED RED SIGNALING WITH INTEGRATED LED BLOCK 110-130VAC CSW-SD1-D61 10046342 146,00

DIFFUSED RED SIGNALING WITH INTEGRATED LED BLOCK 220-240VAC CSW-SD1-D66 10046343 146,00

DIFFUSED GREEN SIGNALING WITH INTEGRATED LED BLOCK 110-130VAC CSW-SD2-D61 10046344 146,00

DIFFUSED GREEN SIGNALING WITH INTEGRATED LED BLOCK 220-240VAC CSW-SD2-D66 10046345 146,00

DIFFUSED CLEAR SIGNALING WITH INTEGRATED LED BLOCK 110-130VAC CSW-SD0-D61 10046346 146,00

DIFFUSED CLEAR SIGNALING WITH INTEGRATED LED BLOCK 220-240VAC CSW-SD0-D66 10046347 146,00

DIFFUSED YELLOW SIGNALING WITH INTEGRATED LED BLOCK 110-130VAC CSW-SD3-D61 10046348 146,00

DIFFUSED YELLOW SIGNALING WITH INTEGRATED LED BLOCK 220-240VAC CSW-SD3-D66 10046349 146,00

DIFFUSED BLUE SIGNALING WITH INTEGRATED LED BLOCK 110-130VAC CSW-SD4-D61 10046350 146,00

DIFFUSED BLUE SIGNALING WITH INTEGRATED LED BLOCK 220-240VAC CSW-SD4-D66 10046351 146,00

DIFFUSED RED SIGNALING WITH RES+DIODE BLOCK 220-240VAC CSW-SD1-RD66 10046352 172,00

DIFFUSED GREEN SIGNALING WITH RES+DIODE BLOCK 220-240VAC CSW-SD2-RD66 10046353 172,00

DIFFUSED YELLOW SIGNALING WITH RES+DIODE BLOCK 220-240VAC CSW-SD3-RD66 10046354 172,00

DIFFUSED CLEAR SIGNALING WITH RES+DIODE BLOCK 220-240VAC CSW-SD0-RD66 10046355 172,00

DIFFUSED BLUE SIGNALING WITH RES+DIODE BLOCK 220-240VAC CSW-SD4-RD66 10046356 172,00

DIFFUSED RED SIGNALING WITH INTEGRATED LED BLOCK 125/VDC CSW-SD1-C13 10046357 146,00

DIFFUSED RED SIGNALING WITH FULL VOLTAGE BLOCK 220VDC WITH NEON LAMP CSW-SD1-LE31 10046358 181,00

DIFFUSED GREEN SIGNALING WITH INTEGRATED LED BLOCK 125/VDC CSW-SD2-C13 10410302 146,00

DIFFUSED GREEN SIGNALING WITH FULL VOLTAGE BLOCK 220VDC WITH NEON LAMP CSW-SD2-LE31 10046359 181,00

Pushbuttons and Pilot Lights - CSW

Note : 1) UL pending.

Page 108: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

212 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 213

COMMON SETS - CSW SERIES

ILLUMINATED PUSHBUTTON

ILLUMINATED SELECTOR SWITCHES

DESCRIPTION TYPE STOCK CODEPRICE EACH

(ZAR)

ILLUMINATED GREEN PUSHBUTTON WITH INTEGRATED LED BLOCK 110-130VAC (1NO) CSW-BFI2-10000000D61 10046515 213,00

ILLUMINATED GREEN PUSHBUTTON WITH INTEGRATED LED BLOCK 220-240VAC (1NO) CSW-BFI2-10000000D66 10186430 213,00

ILLUMINATED RED PUSHBUTTON WITH INTEGRATED LED BLOCK 110-130VAC (1NC) CSW-BFI1-01000000D61 10046516 213,00

ILLUMINATED RED PUSHBUTTON WITH INTEGRATED LED BLOCK 220-240VAC (1NC) CSW-BFI1-01000000D66 10046517 213,00

ILLUMINATED GREEN PUSHBUTTON WITH RES+DIODE BLOCK 220-240VAC (1NO) CSW-BFI2-10000000RD66 10074006 239,00

ILLUMINATED RED PUSHBUTTON WITH RES+DIODE BLOCK 220-240VAC (1NC) CSW-BFI1-01000000RD66 10046518 239,00

ILLUMINATED GREEN PUSHBUTTON WITH INTEGRATED LED BLOCK 125VDC (1NO) CSW-BFI2-10000000C13 10074007 213,00

ILLUMINATED GREEN PUSHBUTTON WITH FULL VOLTAGE BLOCK 220VDC WITH NEON LAMP (1NO) CSW-BFI2-10000000LE31 10452540 230,00

ILLUMINATED RED PUSHBUTTON WITH INTEGRATED LED BLOCK 125VDC (1NC) CSW-BFI1-01000000C13 10074008 213,00

ILLUMINATED RED PUSHBUTTON WITH FULL VOLTAGE BLOCK 220VDC WITH NEON LAMP (1NC) CSW-BFI1-01000000LE31 10452539 230,00

DESCRIPTION TYPE STOCK CODEPRICE EACH

(ZAR)

ILLUM. GREEN KNOB SELECTOR SWITCH 2 FIXED POS. WITH INT. LED BLOCK 110-130VAC (1NO) CSW-CKI2F902-10000000D61 10643921 325,00

ILLUM. GREEN KNOB SELECTOR SWITCH 2 FIXED POS. WITH INT. LED BLOCK 220-240VAC (1NO) CSW-CKI2F902-10000000D66 10046519 325,00

ILLUM. RED KNOB SELECTOR SWITCH 2 FIXED POS. WITH INT. LED BLOCK 110-130VAC (1NO) CSW-CKI2F901-10000000D61 10074009 325,00

ILLUM. RED KNOB SELECTOR SWITCH 2 FIXED POS. WITH INT. LED BLOCK 220-240VAC (1NO) CSW-CKI2F901-10000000D66 10046520 325,00

ILLUM. GREEN KNOB SELECTOR SWITCH 3 FIXED POS. WITH INT. LED BLOCK 110-130VAC (2NO) CSW-CKI3F452-20000000D61 10074010 358,00

ILLUM. GREEN KNOB SELECTOR SWITCH 3 FIXED POS. WITH INT. LED BLOCK 220-240VAC (2NO) CSW-CKI3F452-20000000D66 10046521 358,00

ILLUM. RED KNOB SELECTOR SWITCH 3 FIXED POS. WITH INT. LED BLOCK 110-130VAC (2NO) CSW-CKI3F451-20000000D61 10074011 358,00

ILLUM. RED KNOB SELECTOR SWITCH 3 FIXED POS. WITH INT. LED BLOCK 220-240VAC (2NO) CSW-CKI3F451-20000000D66 10046522 358,00

ILLUM. GREEN KNOB SELECTOR SWITCH 2 FIXED POS. WITH INT. LED BLOCK 125VDC (1NO) CSW-CKI2F902-10000000C13 10074012 325,00

ILLUM. GREEN KNOB SELECTOR SWITCH 2 FIXED POS. WITH FULL VOLTAGE BLOCK 220VDC WITH NEON LAMP (1NO) CSW-CKI2F902-10000000LD66 10643923 342,00

ILLUM. RED KNOB SELECTOR SWITCH 2 FIXED POS. WITH INT. LED BLOCK 125VDC (1NO) CSW-CKI2F901-10000000C13 10074013 325,00

ILLUM. RED KNOB SELECTOR SWITCH 2 FIXED POS. WITH FULL VOLTAGE BLOCK 220VDC WITH NEON LAMP (1NO) CSW-CKI2F901-10000000LE31 10046523 342,00

ILLUM. GREEN KNOB SELECTOR SWITCH 3 FIXED POS. WITH INT. LED BLOCK 125VDC (2NO) CSW-CKI3F452-20000000C13 10074014 358,00

ILLUM. GREEN KNOB SELECTOR SWITCH 3 FIXED POS. WITH FULL VOLTAGE BLOCK 220VDC WITH NEON LAMP (2NO) CSW-CKI3F452-20000000LE31 10074015 364,00

ILLUM. RED KNOB SELECTOR SWITCH 3 FIXED POS. WITH INT. LED BLOCK 125/VDC (2NO) CSW-CKI3F451-20000000C13 10074016 358,00

ILLUM. RED KNOB SELECTOR SWITCH 3 FIXED POS. WITH FULL VOLTAGE BLOCK 220VDC WITH NEON LAMP (2NO) CSW-CKI3F451-20000000LE31 10074017 364,00

Pushbuttons and Pilot Lights - CSW

SIGNALLING

PILOT LIGHT WITH INTEGRATED LED (MONOBLOCK)

RATED VOLTAGE COLOUR PACKING (UNITS) TYPE STOCK CODEPRICE EACH

(ZAR)

12 V ac/dc

Red

10 CEW-SM1-E25 10046535 53,00

24 V ac/dc 10 CEW-SM1-E26 10046540 53,00

110-130 V dc 10 CEW-SM1-C14 10046545 53,00

110 V ac 10 CEW-SM1-D13 10046525 53,00

220 V ac 10 CEW-SM1-D23 10046530 53,00

12 V ac/dc

Green

10 CEW-SM2-E25 10046536 53,00

24 V ac/dc 10 CEW-SM2-E26 10046541 53,00

110-130 V dc 10 CEW-SM2-C14 10046546 53,00

110 V ac 10 CEW-SM2-D13 10046526 53,00

220 V ac 10 CEW-SM2-D23 10046531 53,00

12 V ac/dc

Yellow

10 CEW-SM3-E25 10046537 53,00

24 V ac/dc 10 CEW-SM3-E26 10046542 53,00

110-130 V dc 10 CEW-SM3-C14 10046547 53,00

110 V ac 10 CEW-SM3-D13 10046527 53,00

220 V ac 10 CEW-SM3-D23 10046532 53,00

12 V ac/dc

Blue

10 CEW-SM4-E25 10046538 103,00

24 V ac/dc 10 CEW-SM4-E26 10046543 103,00

110-130 V dc 10 CEW-SM4-C14 10046548 103,00

110 V ac 10 CEW-SM4-D13 10046528 103,00

220 V ac 10 CEW-SM4-D23 10046533 103,00

12 V ac/dc

White

10 CEW-SM0-E25 10046539 103,00

24 V ac/dc 10 CEW-SM0-E26 10046544 103,00

110-130 V dc 10 CEW-SM0-C14 10046549 103,00

110 V ac 10 CEW-SM0-D13 10046529 103,00

220 V ac 10 CEW-SM0-D23 10046534 103,00

Pushbuttons and Pilot Lights - CSW

Page 109: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

214 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 215

Technical Data

PUSHBUTTONS, SELECTOR SWITCHES AND PILOT LIGHTS

CONTACT BLOCK

Applicable standards IEC 60947-5-1, VDE 0660, UL 508, CENELEC EN 50007, ISO 13850 (EN 418), IEC 60947-5-5

Certifications CE, cULus, BV, IRAM, PCT, RCC, ICONTEC

Rated insulation voltage Ui

690 V

Rated impulse voltage Uimp

4 kV

Degree of protection IP20 according to IEC 60529

Conventional thermal current Iith

10 A

Electrical performance according to IEC 60974-5-1

Utilization category AC-15

BC....-CSW BCM01-CSW

Ue (V ac) I

e (A) U

e (V ac) I

e (A)

24 10 24 6

48 10 48 6

60 10 60 6

110 6 110 6

220 3 220 3

380 2 380 2

500 1.5 500 1.5

600 1.2 600 1.2

Utilization category DC-13

Ue (V dc) I

e (A) U

e (V dc) I

e (A)

24 2.5 24 2.5

48 1.4 48 1.4

60 1 60 1

110 0.55 110 0.55

220 0.27 220 0.27

300 0.2 300 0.2

600 0.1 600 0.1

Performance according to UL and CSA AC / Heavy Duty (A600) e DC / Standard Duty (Q600) -

Contact resistance according to IEC 60255 ≤ 25 mΩ

Potection against short circuit (IEC 60269-1 / IEC 60269-3)16 A fuse / 690 V gL/gG (1 kA)

16 A Miniature Circuit Breaker (MDW-B16)

6 A fuse / 500 V gL/gG (0.5 kA)

6 A Miniature Circuit Breaker (MDW-B6)

Electric shock protection according to IEC 60536 Class II

Terminal capacity Minimum (1 x 0.5 mm2) and maximum (2 x 2.5 mm2)

Tightening torque 0.8 N.m

Ambient temperature allowed -25 ºC...+70 ºC

Mechanical shock resistance No damage or disassembling up to 100 g (1/2 senoid 11 rms, according to MIL 202 B method 202 A)

Vibration resistance according to IEC 60068-2-6 16 g for a frequency range of 40 to 500 Hz. Maximum displacement 0.75 mm (peak to peak)

Maximum number of contacts 3-position mounting flange (standard) 5-position mounting flange

BF, BGA pushbuttons 6 8

BC, BD, BFI, BS, BSI, BCI pushbuttons and selector

switches4 8

BCY, BCT pushbuttons and BEG, BEY emergency

pushbuttons4 6

BESG, BESP, BESY emergency pushbuttons 3 (self-monitored blocks) or 4 (single/double blocks) -

Applicable standards IEC 60947-5-1, VDE 0660, UL 508, CENELEC EN 50007, ISO 13850(EN 418), IEC 60947-5-5

Certifications CE, cULus, BV, IRAM, PCT, RCC, ICONTEC

Degree of protectionIP66 and IP 40 (CSW-BD) according to IEC 60529

NEMA 1, 2, 3, 3R, 4, 4X, 5, 12, 12K y 13 according to UL 508

Mechanical lifespan

Pushbuttons 3 x 106 operations

Pushbuttons CSW-BEG/EY/CT/P/Y 3 x 105 operations

Emergency pushbuttons CSW-BESG/P/Y 1 x 105 operations

Selector switches 1 x 106 operations

Use in ambients External (UV ray) or internal

Moulded Case Circuit Breakers

Overview

For power distribution and electric circuits the

circuit breakers DWB_D up to 400 A and DWA up to

800 A ensure overload and short-circuit protections

through thermal and magnetic releases, respectively.

The DWA1600 features an electronic trip unit providing

LSI protection.

DWB_M and DWM circuit breakers are designed to

protect motor branch circuit against short-circuits,

therefore, these circuit breakers trip units have

magnetic releases only. Moreover, they are set in order

to avoid the motor tripping during the starting time of

the motor, when the motor current is up to

8 times its rated current. These circuit breakers are

used in three-component starters along with the

contactor as switching device and the overload relay

for overload protection of the motor.

In generator applications, DWB_G and DWG

circuit breakers are applied to protect generators and,

then, avoid any risks due to short-circuit and overload

situations. Their trip units are composed of thermal and

magnetic releases especially designed to meet the

specific requirements of low fault levels when

protecting a generator.

Finally, IWB and IWA switch-disconnectors are applied

to switch on and off electrical circuits under normal

conditions, this way, these devices are not applied as

protection, therefore they do not have trip units.

DWB and DWA circuit breakers were developed according to IEC 60947-2 standard to protect electrical circuits

for distribution, generator and motor applications in a wide range of rated currents from 16 to 1600 A.

PROTECTING AND DISCONNECTING IN 5 FRAMES

The new DWB circuit breakers are very compact saving space in electrical panels. Its rated current goes from 16 to 400 A in

3 frame sizes:

DWB160 - currents from 16 to 160 A

DWB250 - currents from 80 to 250 A DWB400 - currents from 160 to 400 A

In applications above 400 A, DWA circuit breakers complement the solution providing protection up to 1600 A.

DWA800 - currents from 350 to 800 A

DWA1600_E - currents from 500 to 1600 A

THE RIGHT CIRCUIT BREAKER FOR YOUR APPLICATION

Page 110: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

216 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 217

Moulded Case Circuit Breakers

FLEXIBILITY

WEG DWB range offers full flexibility for customers when fitting internal accessories, because the auxiliary contact blocks are

common for frames 160, 250 and 400 moreover the shunt and undervoltage releases are common for frames 160 and 250.

EASINESS FOR REPLACEMENT

Through the transparent front cover of DWB circuit breakers, it can be

easily identified which accessories are installed.

DOUBLE PROTECTION

Oriented to provide safe solutions to electricians, WEG circuit breakers have double insulation between live parts and the front

of the equipment, except terminals. Besides that, internal accessories were designed to be completely separate from the power

circuit, this way avoiding any risk of contact with live parts.

HIGH PERFORMANCE

The WEG moulded case circuit breakers can be used in a

wide range of applications providing quick protection against

short-circuits.

Along with WEG contactors and WEG smart relay, DWB

range fulfills the requirements of type 2 coordination according

to standard IEC 60947-4-1.

Short-circuit breaking capacity @ 380 / 415 V

DWB160 DWB250 DWB400 DWA800 DWA1600

L 80 kA

H 65 kA

S 50 kA

N 35 kA1)

B 16 kA

Note: 1) Except DWB160N that breaks up to 30 kA.

Notes: 1) Not applicable for DWA1600.

2) For other temperatures, see section Installation and connections.

3) Circuit breakers with rated currents of 16, 20, 25 and 32 A, the short-circuit breaking capacity Icu is 20 kA.

4) Circuit breakers with rated currents of 16, 20, 25 and 32 A, the short-circuit breaking capacity Icu is 15 kA.

5) Valid for DWA800 up to 630 A.

6) Not considering phase barriers and/or terminal covers.

Electrical characteristics according to IEC 60947-2

Rated current - In (45 °C)2) A 160 250

Number of poles 2, 3, 4 2, 3, 4

Insulation voltage - Ui V 800 800

Short-circuit breaking capacity levels B N L B N L

Rated ultimate short-circuit

breaking capacity - Icu

kA rms

220-240 V 25 50 120 42 85 120

380-415 V 16 303) 80 16 35 80

440 V 10 204) 80 15 30 80

460-500 V 5 8 65 5 8 65

525-550 V 4 6 25 4 7 25

660-690 V 3 4 10 3 6 15

Rated service short-circuit

breaking capacity - Ics

% Icu

220-240 V 100% 50% 75% 100% 50% 75%

380-415 V 100% 50% 75% 100% 50% 75%

440 V 100% 50% 75% 100% 50% 75%

460-500 V 100% 50% 75% 100% 50% 50%

525-550 V 100% 50% 75% 100% 50% 100%

660-690 V 100% 75% 100% 100% 75% 75%

Mechanical lifespan (C-O)Number of operations 8000

120

8000

Operations per hour 120

Electrical lifespan (C-O)Number of operations 1000

120

1000

Operations per hour 120

Protection

Against short-circuit & overload (fixed thermomagnetic) Yes No

Against short-circuit & overload (adjustable thermal and fixed magnetic) Yes Yes

Against short-circuit & overload (adjustable thermomagnetic) No No

LSI (electronic) No No

Against short-circuit (magnetic only) Yes Yes

Switch-disconnector (no trip unit) Yes Yes

Installation and connections

Cables

Maximum cross-section mm² 70

4

6

120

Minimum cross-section mm² 25

Torque tightening Nm 25

BusbarsMaximum width mm² 11

6

24

Torque tightening Nm 8

Dimensions W (W-4P) x D x H mm 78 (102.5) x 71 x 1226) 78 x 136 x 1436) 105 (141) x 78 x 1626) 105 x 137 x 1916)

Weight 2/3 poles (4 poles) kg 0.95 (1.2) 1.84 1.85 (1.92) 3.8

Common characteristics

Designed according to IEC 60947-2

Rated voltages

Rated operational voltage - UeV ac (50 / 60 Hz) 690

V dc 2501)

Rated impulse withstand voltage - Uimp kV 8

Other characteristics

Selectivity category A

Pollution degree 3

Maximum relative humidity 95%

DWB160 DWB250

Overview and Technical Data

Page 111: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

218 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 219

400 800 1600

2, 3, 4 2, 3, 4 2, 3, 4

800 690 690

N H N H S H

65 80 65 80 80 100

35 65 35 65 50 65

35 65 35 65 50 65

25 50 25 50 40 50

-

20 25 20 25 30 35

100% 75% 100% 75% 100% 75%

100% 75% 100% 75% 100% 75%

100% 75% 100% 75% 100% 75%

100% 75% 100% 75% 100% 75%

100% 75% 100% 75% 100% 75%

5000

120

5000

120

3000

120

1000

120

10005) 500 500

120 1205) 120

No No No

No No No

Yes Yes No

No No Yes

Yes Yes Yes

Yes Yes Yes

240

35

30

2 x 240

1 x 185

40

4 x 240

3 x 185 / 2 x 24045

2220

5020 (M8) / 50 (M12)

5030 (M10) / 50 (M12)

107 (141) x 99 x 2576) 210 (280) x 97 x 2576) 210 (280) x 146 x 3456)

3.6 (4.6) 7.4 (9.2) 19 (25)

DWB400 DWA800 DWA1600

Trip Units

Ratings In (A) @ 45 ºC 16 20 25 32 40 50 55 63 70 75 80 85 90 100 105 110 125 140 150 160

DWB160_DX x x x x x x x x x x x x x x x

DWB160_GX x x x x x x x

Thermal protection

Current setting (A) - Ir Fixed Ir = In

Magnetic protection

Im (A) Fixed

DWB160_DX 300 300 300 320 400 500 630 700 800 900 1000 1100 1100 1100 1100

DWB160_GX 300 375 425 525 630 700 800

Ratings In (A) @ 45 ºC 40 50 55 63 75 80 85 100 105 125 140 160 200 250

Ir

DWB160_DF x x x x x x x

DWB250_DF x x x x x

DWB160_GF x x x x x x x

DWB250_GF x x x x x

Thermal protection

Current setting (A) - Ir Adjustable from 0.8 to 1 x In

Magnetic protection

Im (A) Fixed

DWB160_DF 400 500 630 800 1000 1100 1100

DWB250_DF 1000 1250 1600 2000 2500

DWB160_GF 300 375 425 525 630 700 800

DWB250_GF 500 630 800 1000 1250

Ratings In (A) @ 45 ºC 100 125 160 200 250 320 400 500 630 800 1000 1250 1600

Ir

Im

DWB400_DA x x x x x x x

DWA800 x x x x x

DWB400_GA x x x x

DWG800 x x x x x

Thermal protection

Current setting (A) - Ir Adjustable from 0.8 to 1 x In1)

Magnetic protection

Im (A) Adjustable from 5 to 10 x In

DWB400_DA 1000 1250 1600 2000 2500 3200 4000

DWA800 3200 4000 5000 6300 64002)

Im (A) Adjustable from 2.5 to 5 x In

DWB400_GA 1000 1250 1600 2000

DWG800 1600 2000 2500 3150 4000

Notes: 1) Thermal protection of DWA800 and DWG800 frames is adjustable from 0.7 to 1 x In.

2) Magnetic protection of DWA800 800 A is adjustable from 4 to 8 x In.

WEG breakers have a wide range of trip units to better fit into the application. Thermomagnetic and electronic trip units are

available depending on the frame size.

FIXED THERMAL AND FIXED MAGNETIC

ADJUSTABLE THERMAL AND FIXED MAGNETIC

ADJUSTABLE THERMAL AND ADJUSTABLE MAGNETIC

Page 112: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

220 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 221

Trip Units

Ratings In (A) @ 45 ºC 25 32 40 50 65 80 95 105 150 185 200

DWB160_MF x x x x x x x

DWB250_MF x x x x x

Thermal protection

Current setting (A) - Ir Not available

Magnetic protection

Im (A) Fixed

DWB160_MF 300 385 480 600 780 960 1140

DWB250_MF 960 1260 1800 2220 2400

Ratings In (A) @ 45 ºC 150 185 250 320 420 500 700 800 1000

Im

DWB400_MA x x x x

DWM800 x x

DWM1600 x x x

Thermal protection

Current setting (A) - Ir Not available

Magnetic protection

Im (A) Adjustable from 7.5 to 15 x In

DWB400_MA 2250 2775 3750 4800

DWM800 6300 7500

DWM1600 10500 12000 15000

46

8

1012

2.7

.8

.9

.951

.65

6

7

810

4

.4

.5 3

2

I

x Inx In x Ir

L S

IiIr Is

.3.4

.1

.2.3

.2

.1

.4

70% 105%

3

1.6

12

18

6 at 8xIr (s)tr ts

2I t OFF

2I t ON

at 6xIr (s)

Ratings In (A) @ 45 ºC 1250 1600

Is

Ii

ts

tr

IrDWA1600 x x

Thermal protection

Current setting (A) - Ir Adjustable from 0.4 to 1 x In

Magnetic protection

Im (A) Adjustable from 2 to 12 x In

DWA1600 15000 19200

ELECTRONIC LSI

L - Long time delay trip function (protection against overloads).

S - Short time delay trip function (protection against short-circuit with time delay).

I - Instantaneous trip function (instantaneous protection against short-circuit).

FIXED MAGNETIC

ADJUSTABLE MAGNETIC

STATUS SIGNALING

70% / 105%:

LED ON when the current passing through the device reaches 70% of In LED intermittent when the current passing through the device reaches 105% of In

During circuit breaker reset, LEDs will indicate which protection (L, S or I) was actuated in the last trip, flashing 10 times.

The electronic protection of the circuit breaker is self-powered since the protected circuit provides the necessary energy

for its operation.

Moulded Case Circuit-Breakers - DWB Distribution - 3-Pole

FIXED THERMAL AND MAGNETIC RELEASES - DWB160-D

TYPE Ln (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWB160B16-3DX 16 25 16 10 11339625 1541,00

DWB160B20-3DX 20 25 16 10 11339626 1541,00

DWB160B25-3DX 25 25 16 10 11339627 1541,00

DWB160B32-3DX 32 25 16 10 11339638 1541,00

DWB160B40-3DX 40 25 16 10 11339640 1541,00

DWB160B50-3DX 50 25 16 10 11339641 1541,00

DWB160B63-3DX 63 25 16 10 11339642 1541,00

DWB160B70-3DX 70 25 16 10 11339643 1541,00

DWB160B80-3DX 80 25 16 10 11339644 1541,00

DWB160B90-3DX 90 25 16 10 11339645 1541,00

DWB160B100-3DX 100 25 16 10 11322258 1541,00

DWB160B110-3DX 110 25 16 10 11339646 1618,00

DWB160B125-3DX 125 25 16 10 11339647 1618,00

DWB160B150-3DX 150 25 16 10 11339658 1618,00

DWB160B160-3DX 160 25 16 10 11339659 1618,00

TYPE Ln (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWB160N16-3DX 16 50 25 20 11339663 1695,00

DWB160N20-3DX 20 50 25 20 11339664 1695,00

DWB160N25-3DX 25 50 25 20 11339665 1695,00

DWB160N32-3DX 32 50 25 20 11339667 1695,00

DWB160N40-3DX 40 50 30 25 11339698 1695,00

DWB160N50-3DX 50 50 30 25 11339699 1695,00

DWB160N63-3DX 63 50 30 25 11339700 1695,00

DWB160N70-3DX 70 50 30 25 11339701 1695,00

DWB160N80-3DX 80 50 30 25 11339702 1695,00

DWB160N90-3DX 90 50 30 25 11339703 1695,00

DWB160N100-3DX 100 50 30 25 11339704 1695,00

DWB160N110-3DX 110 50 30 25 11339705 1772,00

DWB160N125-3DX 125 50 30 25 11339706 1772,00

DWB160N150-3DX 150 50 30 25 11339707 1772,00

DWB160N160-3DX 160 50 30 25 11339718 1772,00

LOW BREAKING CAPACITY DWB160B - 3-POLE

Normal Breaking Capacity DWB160N - 3-Pole

Page 113: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

222 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 223

Moulded Case Circuit-Breakers - DWB Distribution - 3-Pole

FIXED THERMAL AND MAGNETIC RELEASES - DWB160-D

TYPE Ln (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWB160L16-3DX 16 120 80 80 11339721 3544,00

DWB160L20-3DX 20 120 80 80 11339722 3544,00

DWB160L25-3DX 25 120 80 80 11339723 3544,00

DWB160L32-3DX 32 120 80 80 11339724 3544,00

DWB160L40-3DX 40 120 80 80 11339725 3544,00

DWB160L50-3DX 50 120 80 80 11339726 3544,00

DWB160L63-3DX 63 120 80 80 11339727 3544,00

DWB160L70-3DX 70 120 80 80 11339748 3544,00

DWB160L80-3DX 80 120 80 80 11339749 3544,00

DWB160L90-3DX 90 120 80 80 11339750 3544,00

DWB160L100-3DX 100 120 80 80 11339751 3544,00

DWB160L110-3DX 110 120 80 80 11339753 3698,00

DWB160L125-3DX 125 120 80 80 11339754 3698,00

HIGH BREAKING CAPACITY DWB160L - 3-POLE

Moulded Case Circuit-Breakers - DWB Distribution - 3-Pole

ADJUSTABLE THERMAL AND FIXED MAGNETIC RELEASES - DWB160-D

TYPE Ln (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWB160B40-3DF 32...40 25 16 10 11631355 1618,00

DWB160B50-3DF 40...50 25 16 10 11631358 1618,00

DWB160B63-3DF 50...63 25 16 10 11631361 1618,00

DWB160B80-3DF 64...80 25 16 10 11631364 1618,00

DWB160B100-3DF 80...100 25 16 10 11631367 1618,00

DWB160B125-3DF 100...125 25 16 10 11631380 1772,00

DWB160B160-3DF 128...160 25 16 10 11631383 1772,00

LOW BREAKING CAPACITY DWB160B - 3-POLE

TYPE Ln (A)

IEC60947-2 - Icu

(kA)STOCK CODE

PRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWB160N40-3DF 32...40 50 30 25 11631362 1772,00

DWB160N50-3DF 40...50 50 30 25 11631363 1772,00

DWB160N63-3DF 50...63 50 30 25 11631365 1772,00

DWB160N80-3DF 64...80 50 30 25 11631366 1772,00

DWB160N100-3DF 80...100 50 30 25 11631378 1772,00

DWB160N125-3DF 100...125 50 30 25 11631379 1849,00

DWB160N160-3DF 128...160 50 30 25 11631381 1849,00

NORMAL BREAKING CAPACITY DWB160N - 3-POLE

TYPE Ln (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWB160L40-3DF 32...40 120 80 80 11631340 3852,00

DWB160L50-3DF 40...50 120 80 80 11631342 3852,00

DWB160L63-3DF 50...63 120 80 80 11631343 3852,00

DWB160L80-3DF 64...80 120 80 80 11631344 3852,00

DWB160L100-3DF 80...100 120 80 80 11631346 3852,00

HIGH BREAKING CAPACITY DWB160L - 3-POLE

Page 114: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

224 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 225

Moulded Case Circuit-Breakers - DWB Distribution - 3-Pole

ADJUSTABLE THERMAL AND FIXED MAGNETIC RELEASES - DWB250-D

TYPE Ln (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWB250B100-3DF 80...100 42 16 15 11339768 2743,00

DWB250B125-3DF 100...125 42 16 15 11339769 2743,00

DWB250B160-3DF 125...160 42 16 15 11339770 2743,00

DWB250B200-3DF 160...200 42 16 15 11339772 2914,00

DWB250B250-3DF 200...250 42 16 15 11339773 2914,00

TYPE Ln (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWB250N100-3DF 80...100 85 35 30 11339775 3017,00

DWB250N125-3DF 100...125 85 35 30 11339776 3017,00

DWB250N160-3DF 125...160 85 35 30 11339777 3017,00

DWB250N200-3DF 160...200 85 35 30 11339798 3206,00

DWB250N250-3DF 200...250 85 35 30 11339799 3206,00

TYPE Ln (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWB250L100-3DF 80...100 120 80 80 11339801 7713,00

DWB250L125-3DF 100...125 120 80 80 11339802 7713,00

DWB250L160-3DF 125...160 120 80 80 11339803 7713,00

DWB250L200-3DF 160...200 120 80 80 11339804 7884,00

LOW BREAKING CAPACITY DWB250B - 3-POLE

NORMAL BREAKING CAPACITY DWB250N - 3-POLE

HIGH BREAKING CAPACITY DWB250L - 3-POLE

Moulded Case Circuit-Breakers - DWB Distribution - 3-Pole

ADJUSTABLE THERMAL AND MAGNETIC RELEASES - DWB400

TYPE RATED CURRENT (A) Lm (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWB400N200-3DA 160...200 1000...2000 65 35 35 12534150 5009,00

DWB400N250-3DA 200...250 1250...2500 65 35 35 12534149 5009,00

DWB400N320-3DA 250...320 1600...3200 65 35 35 12534148 5724,00

DWB400N400-3DA 320...400 2000...4000 65 35 35 12534127 5724,00

TYPE RATED CURRENT (A) Lm (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWB400H200-3DA 160...200 1000...2000 80 65 65 12534122 5724,00

DWB400H250-3DA 200...250 1250...2500 80 65 65 12534121 5724,00

DWB400H320-3DA 250...320 1600...3200 80 65 65 12534120 6154,00

DWB400H400-3DA 320...400 2000...4000 80 65 65 12534106 6154,00

NORMAL BREAKING CAPACITY DWB400N - 3-POLE

HIGH BREAKING CAPACITY DWB400H - 3-POLE

Page 115: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

226 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 227

Moulded Case Circuit-Breakers - DWA Distribution - 3-Pole

Moulded Case Circuit-Breakers - DWA Distribution and Generator

Protection - 3-Pole

ADJUSTABLE THERMAL AND MAGNETIC RELEASES - DWA800

ELECTRONIC TRIP UNIT LSI - DWA1600-E

TYPE RATED CURRENT (A) Lm (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWA800N-500-3 350...500 2500...5000 65 35 35 10046815 12683,00

DWA800N-630-3 440...630 3150...6300 65 35 35 10046816 12683,00

DWA800N-800-3 560...800 3200...6400 65 35 35 10046752 18288,00

TYPE RATED CURRENT (A) Lm (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWA1600S-E1250-3 500...1250 6250...12500 80 50 50 12282712 23399,00

DWA1600S-E1600-3 640...1600 8000...16000 80 50 50 11968153 28317,00

TYPE RATED CURRENT (A) Lm (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWA1600H-E1250-3 500...1250 6250...12500 100 65 65 12282714 27870,00

DWA1600H-E1600-3 640...1600 8000...16000 100 65 65 12282713 29882,00

NORMAL BREAKING CAPACITY DWA800N - 3-POLE

NORMAL BREAKING CAPACITY DWA1600S - 3-POLE

HIGH BREAKING CAPACITY DWA1600H - 3-POLE

TYPE RATED CURRENT (A) Lm (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWA800H-500-3 350...500 2500...5000 80 65 65 10046750 13129,00

DWA800H-630-3 440...630 3150...6300 80 65 65 10046746 13129,00

DWA800H-800-3 560...800 3200...6400 80 65 65 10186510 19693,00

HIGH BREAKING CAPACITY DWA800H - 3-POLE

Moulded Case Circuit-Breakers - DWB M Motor Branch Circuit Protection

- 3-Pole

FIXED MAGNETIC RELEASE ONLY - DWB160-M

TYPE Ln (A) L

m (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWB160N25-3MF 25 300 50 25 15 11339864 1849,00

DWB160N32-3MF 32 385 50 25 15 11339865 1849,00

DWB160N40-3MF 40 480 50 30 20 11339866 1849,00

DWB160N50-3MF 50 600 50 30 20 11339867 1941,00

DWB160N65-3MF 65 780 50 30 20 11339928 1941,00

DWB160N80-3MF 80 960 50 30 20 11339929 1941,00

DWB160N95-3MF 95 1140 50 30 20 11339930 1941,00

TYPE Ln (A) L

m (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWB160L25-3MF 25 300 120 80 80 11339936 3852,00

DWB160L32-3MF 32 385 120 80 80 11339937 3852,00

DWB160L40-3MF 40 480 120 80 80 11339948 3852,00

DWB160L50-3MF 50 600 120 80 80 11339950 4006,00

DWB160L65-3MF 65 780 120 80 80 11339951 4006,00

DWB160L80-3MF 80 960 120 80 80 11339952 4006,00

DWB160L95-3MF 95 1140 120 80 80 11339953 4006,00

LOW BREAKING CAPACITY DWB160N - 3-POLE

HIGH BREAKING CAPACITY DWB160L - 3-POLE

Page 116: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

228 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 229

Moulded Case Circuit-Breakers - DWB M Motor Branch Circuit

Protection - 3-Pole

FIXED MAGNETIC RELEASE ONLY - DWB250-M

ADJUSTABLE MAGNETIC RELEASE ONLY - DWB400-M

TYPE Ln (A) L

m (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWB250N80-3MF 80 960 85 35 30 11340029 3171,00

DWB250N105-3MF 105 1260 85 35 30 11340031 3171,00

DWB250N150-3MF 150 1800 85 35 30 11340032 3171,00

DWB250N185-3MF 185 2220 85 35 30 11340033 3171,00

DWB250N200-3MF 200 2400 85 35 30 11631304 3343,00

TYPE Ln (A) L

m (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWB250L80-3MF 80 960 120 80 80 11340035 7970,00

DWB250L105-3MF 105 1260 120 80 80 11340037 7970,00

DWB250L150-3MF 150 1800 120 80 80 11340058 7970,00

DWB250L185-3MF 185 2220 120 80 80 11340059 7970,00

DWB250L200-3MF 200 2400 120 80 80 11631305 8227,00

TYPE Ln (A) L

m (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWB400H150-3MA 150 1125...2250 80 65 65 12534076 6011,00

DWB400H185-3MA 185 1400...2775 80 65 65 12534075 6011,00

DWB400H250-3MA 250 1900...3750 80 65 65 12534074 6011,00

DWB400H320-3MA 320 2400...4800 80 65 65 12534073 6440,00

NORMAL BREAKING CAPACITY DWB250N - 3-POLE

HIGH BREAKING CAPACITY DWB250L - 3-POLE

NORMAL BREAKING CAPACITY DWB400H - 3-POLE

Moulded Case Circuit-Breakers - DWM Motor Branch Circuit

Protection - 3-Pole

ADJUSTABLE MAGNETIC RELEASE ONLY - DWM800

ADJUSTABLE MAGNETIC RELEASE ONLY - DWM1600

TYPE Ln (A) L

m (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWM800H-420-3 420 3150...6300 80 65 65 10186515 15768,00

DWM800H-500-3 500 3750...7500 80 65 65 10118332 15768,00

TYPE Ln (A) L

m (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWM1600H-700-3 700 5250...10500 100 65 65 10046955 24591,00

DWM1600H-800-3 800 6000...12000 100 65 65 10046956 26827,00

DWM1600H-1000-3 1000 7500...15000 100 65 65 10046957 26827,00

HIGH BREAKING CAPACITY DWM800H - 3-POLE

HIGH BREAKING CAPACITY DWM1600H - 3-POLE

Note : DWM and DWG use the same accessories of DWA range.

Page 117: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

230 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 231

Moulded Case Circuit-Breakers - DWB G Generator Protection - 3-Pole

FIXED THERMAL AND MAGNETIC RELEASES - DWB160-G

ADJUSTABLE THERMAL AND FIXED MAGNETIC RELEASES - DWB160-G

ADJUSTABLE THERMAL AND FIXED MAGNETIC RELEASES - DWB250-G

TYPE Ln (A) L

m (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWB160B55-3GX 55 300 25 16 10 11340061 2003,00

DWB160B75-3GX 75 375 25 16 10 11340062 2003,00

DWB160B85-3GX 85 425 25 16 10 11340063 2003,00

DWB160B105-3GX 105 525 25 16 10 11340064 2003,00

DWB160B125-3GX 125 625 25 16 10 11340066 2157,00

DWB160B140-3GX 140 700 25 16 10 11340067 2157,00

DWB160B160-3GX 160 800 25 16 10 11340068 2157,00

TYPE Lr (A) L

m (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWB160B55-3GF 44...55 300 25 16 10 11631274 2103,00

DWB160B75-3GF 60...75 375 25 16 10 11631275 2103,00

DWB160B85-3GF 68...85 425 25 16 10 11631277 2103,00

DWB160B105-3GF 84...105 525 25 16 10 11631300 2103,00

DWB160B125-3GF 100...125 625 25 16 10 11631301 2265,00

DWB160B140-3GF 112...140 700 25 16 10 11631302 2265,00

DWB160B160-3GF 128...160 800 25 16 10 11631303 2265,00

TYPE Lr (A) L

m (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWB250B105-3GF 80...105 500 42 17 15 11340071 3257,00

DWB250B125-3GF 100...125 625 42 17 15 11340072 3257,00

DWB250B160-3GF 125...160 800 42 17 15 11340073 3257,00

DWB250B200-3GF 160...200 1000 42 17 15 11340074 3343,00

DWB250B250-3GF 200...250 1250 42 17 15 11340075 3428,00

LOW BREAKING CAPACITY DWB160B - 3-POLE

LOW BREAKING CAPACITY DWB160B - 3-POLE

LOW BREAKING CAPACITY DWB250B - 3-POLE

ADJUSTABLE THERMAL AND MAGNETIC RELEASES - DWB400-G

ADJUSTABLE THERMAL AND MAGNETIC RELEASES - DWG800

NORMAL BREAKING CAPACITY DWB400N - 3-POLE

NORMAL BREAKING CAPACITY DWG800N - 3-POLE

TYPE Lr (A) L

m (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWB400N200-3GA 160...200 500...1000 65 35 35 12534082 5724,00

DWB400N250-3GA 200...250 625...1250 65 35 35 12534079 5724,00

DWB400N320-3GA 250...320 800...1600 65 35 35 12534078 6583,00

DWB400N400-3GA 320...400 1000...2000 65 35 35 12534077 6583,00

TYPE Lr (A) L

m (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWG800N-500-3 350-500 1250...2500 65 35 35 10046766 14226,00

DWG800N-630-3 440-630 1575...3150 65 35 35 10046767 14226,00

DWG800N-800-3 560-800 2000...4000 65 35 35 10046768 19882,00

Note : DWM and DWG use the same accessories of DWA range.

Moulded Case Circuit-Breakers - DWB G Generator Protection - 3-Pole

Moulded Case Circuit Breakers - DWG - 3-Pole

Page 118: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

232 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 233

Moulded Case Circuit-Breakers - DWA Distribution and Generator

Protection - 3-Pole

Switch Disconnectors - IWB - 3-Pole

Switch Disconnectors - IWA - 3-Pole

ELECTRONIC TRIP UNIT LSI - DWA1600-E

NORMAL BREAKING CAPACITY DWA1600S - 3-POLE

HIGH BREAKING CAPACITY DWA1600H - 3-POLE

TYPE RATED CURRENT (A) l (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWA1600S-E1250-3 500...1250 6250...12500 80 50 50 12282712 23399,00

DWA1600S-E1600-3 640...1600 8000...16000 80 50 50 11968153 28317,00

TYPE RATED CURRENT (A) l (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWA1600H-E1250-3 500...1250 6250...12500 100 65 65 12282714 27870,00

DWA1600H-E1600-3 640...1600 8000...16000 100 65 65 12282713 29882,00

TYPE Lm (A) FRAME SIZE STOCK CODE

PRICE EACH

(ZAR)

IWB160-160-3XX 160 DWB160 11340103 1629,00

IWB250-250-3XX 250 DWB250 11344866 2571,00

IWB400-250-3XX 250 DWB400 12532356 5009,00

IWB400-400-3XX 400 DWB400 12530957 5009,00

TYPE Lm (A) FRAME SIZE STOCK CODE

PRICE EACH

(ZAR)

IWA800630-3 630 DWA800 10186516 11998,00

IWA800800-3 800 DWA800 10186517 16968,00

IWA16001000-3 1000 DWA1600 10186547 25709,00

IWA16001250-3 1250 DWA1600 10074691 28280,00

IWA16001600-3 1600 DWA1600 10186507 30165,00

Note : IWB/IWA use the same accessories of DWB/DWA ranges.

Moulded Case Circuit-Breakers - DWB Distribution - 4-Pole - Neutral

Not Protected

FIXED THERMAL AND MAGNETIC RELEASES - DWB160-D

LOW BREAKING CAPACITY DWB160B - 4-POLE

NORMAL BREAKING CAPACITY DWB160N - 4-POLE

TYPE In (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWB160B16-4DX 16 25 16 10 12318372 2003,00

DWB160B20-4DX 20 25 16 10 12318373 2003,00

DWB160B25-4DX 25 25 16 10 12318374 2003,00

DWB160B32-4DX 32 25 16 10 12318375 2003,00

DWB160B40-4DX 40 25 16 10 12318376 2003,00

DWB160B50-4DX 50 25 16 10 12318377 2003,00

DWB160B63-4DX 63 25 16 10 12318458 2003,00

DWB160B70-4DX 70 25 16 10 12318459 2003,00

DWB160B80-4DX 80 25 16 10 12318460 2003,00

DWB160B90-4DX 90 25 16 10 12318461 2003,00

DWB160B100-4DX 100 25 16 10 12318462 2003,00

DWB160B110-4DX 110 25 16 10 12318463 2103,00

DWB160B125-4DX 125 25 16 10 12318464 2103,00

DWB160B150-4DX 150 25 16 10 12318465 2103,00

DWB160B160-4DX 160 25 16 10 12318466 2103,00

TYPE In (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWB160N16-4DX 16 50 25 20 12318568 2203,00

DWB160N20-4DX 20 50 25 20 12318569 2203,00

DWB160N25-4DX 25 50 25 20 12318570 2203,00

DWB160N32-4DX 32 50 25 20 12318571 2203,00

DWB160N40-4DX 40 50 30 25 12318572 2203,00

DWB160N50-4DX 50 50 30 25 12318573 2203,00

DWB160N63-4DX 63 50 30 25 12318574 2203,00

DWB160N70-4DX 70 50 30 25 12318575 2203,00

DWB160N80-4DX 80 50 30 25 12318577 2203,00

DWB160N90-4DX 90 50 30 25 12318631 2203,00

DWB160N100-4DX 100 50 30 25 12318632 2203,00

DWB160N110-4DX 110 50 30 25 12318633 2303,00

DWB160N125-4DX 125 50 30 25 12318634 2303,00

DWB160N150-4DX 150 50 30 25 12318635 2303,00

DWB160N160-4DX 160 50 30 25 12318636 2303,00

Page 119: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

234 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 235

Moulded Case Circuit-Breakers - DWB Distribution - 4-Pole - Neutral

Protected - 50%

FIXED THERMAL AND MAGNETIC RELEASES - DWB160-D

LOW BREAKING CAPACITY DWB160B - 4-POLE

NORMAL BREAKING CAPACITY DWB160N - 4-POLE

TYPE In (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWB160B150-4DXP 150 25 16 10 12318467 2103,00

DWB160B160-4DXP 160 25 16 10 12318468 2103,00

TYPE In (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWB160N150-4DXP 150 50 30 20 12318637 2303,00

DWB160N160-4DXP 160 50 30 20 12318658 2303,00

Moulded Case Circuit-Breakers - DWB Distribution - 4-Pole - Neutral

Protected - 100%

FIXED THERMAL AND MAGNETIC RELEASES - DWB160-D

LOW BREAKING CAPACITY DWB160B - 4-POLE

NORMAL BREAKING CAPACITY DWB160N - 4-POLE

TYPE In (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWB160B16-4DXT 16 25 16 10 12318469 2003,00

DWB160B20-4DXT 20 25 16 10 12318470 2003,00

DWB160B25-4DXT 25 25 16 10 12318472 2003,00

DWB160B32-4DXT 32 25 16 10 12318473 2003,00

DWB160B40-4DXT 40 25 16 10 12318474 2003,00

DWB160B50-4DXT 50 25 16 10 12318475 2003,00

DWB160B63-4DXT 63 25 16 10 12318476 2003,00

DWB160B70-4DXT 70 25 16 10 12318488 2003,00

DWB160B80-4DXT 80 25 16 10 12318489 2003,00

DWB160B90-4DXT 90 25 16 10 12318490 2003,00

DWB160B100-4DXT 100 25 16 10 12318491 2003,00

DWB160B110-4DXT 110 25 16 10 12318492 2103,00

DWB160B125-4DXT 125 25 16 10 12318493 2103,00

DWB160B150-4DXT 150 25 16 10 12318494 2103,00

DWB160B160-4DXT 160 25 16 10 12318495 2103,00

TYPE In (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWB160N16-4DXT 16 50 25 15 12318659 2203,00

DWB160N20-4DXT 20 50 25 15 12318660 2203,00

DWB160N25-4DXT 25 50 25 15 12318661 2203,00

DWB160N32-4DXT 32 50 25 15 12318663 2203,00

DWB160N40-4DXT 40 50 30 20 12318664 2203,00

DWB160N50-4DXT 50 50 30 20 12318665 2203,00

DWB160N63-4DXT 63 50 30 20 12318666 2203,00

DWB160N70-4DXT 70 50 30 20 12318667 2203,00

DWB160N80-4DXT 80 50 30 20 12318698 2203,00

DWB160N90-4DXT 90 50 30 20 12318699 2203,00

DWB160N100-4DXT 100 50 30 20 12318701 2203,00

DWB160N110-4DXT 110 50 30 20 12318702 2303,00

DWB160N125-4DXT 125 50 30 20 12318703 2303,00

DWB160N150-4DXT 150 50 30 20 12318704 2303,00

DWB160N160-4DXT 160 50 30 20 12318705 2303,00

Page 120: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

236 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 237

Moulded Case Circuit-Breakers - DWB Distribution - 4-Pole - Neutral

Not Protected

ADJUSTABLE THERMAL AND FIXED MAGNETIC RELEASES - DWB160-D 1)

LOW BREAKING CAPACITY DWB160B - 4-POLE

NORMAL BREAKING CAPACITY DWB160N - 4-POLE

TYPE In (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWB160B40-4DF 32...40 25 16 10 12318002 2103,00

DWB160B50-4DF 40...50 25 16 10 12318003 2103,00

DWB160B63-4DF 50...63 25 16 10 12318005 2103,00

DWB160B80-4DF 64...80 25 16 10 12318007 2103,00

DWB160B100-4DF 80...100 25 16 10 12318008 2103,00

DWB160B125-4DF 100...125 25 16 10 12318009 2211,00

DWB160B160-4DF 128...160 25 16 10 12318010 2211,00

TYPE In (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWB160N40-4DF 32...40 50 30 25 12318160 2319,00

DWB160N50-4DF 40...50 50 30 25 12318161 2319,00

DWB160N63-4DF 50...63 50 30 25 12318162 2319,00

DWB160N80-4DF 64...80 50 30 25 12318163 2319,00

DWB160N100-4DF 80...100 50 30 25 12318164 2319,00

DWB160N125-4DF 100...125 50 30 25 12318221 2419,00

DWB160N160-4DF 128...160 50 30 25 12318222 2419,00

Moulded Case Circuit-Breakers - DWB Distribution - 4-Pole - Neutral

Protected - 50%

ADJUSTABLE THERMAL AND FIXED MAGNETIC RELEASES - DWB160-D

LOW BREAKING CAPACITY DWB160B - 4-POLE

NORMAL BREAKING CAPACITY DWB160N - 4-POLE

TYPE In (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWB160B160-4DFP 128...160 25 16 10 12318012 2211,00

TYPE In (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWB160N160-4DFP 128...160 50 30 20 12318223 2419,00

Page 121: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

238 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 239

Moulded Case Circuit-Breakers - DWB Distribution - 4-Pole - Neutral

Protected - 100%

ADJUSTABLE THERMAL AND FIXED MAGNETIC RELEASES - DWB160-D

LOW BREAKING CAPACITY DWB160B - 4-POLE

NORMAL BREAKING CAPACITY DWB160N - 4-POLE

TYPE In (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWB160B40-4DFT 40 25 16 10 12318132 2103,00

DWB160B50-4DFT 50 25 16 10 12318135 2103,00

DWB160B63-4DFT 63 25 16 10 12318136 2103,00

DWB160B80-4DFT 80 25 16 10 12318138 2103,00

DWB160B100-4DFT 100 25 16 10 12318142 2103,00

DWB160B125-4DFT 125 25 16 10 12318143 2211,00

DWB160B160-4DFT 160 25 16 10 12318144 2211,00

TYPE In (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWB160N40-4DFT 40 50 30 20 12318227 2319,00

DWB160N50-4DFT 50 50 30 20 12318238 2319,00

DWB160N63-4DFT 63 50 30 20 12318240 2319,00

DWB160N80-4DFT 80 50 30 20 12318242 2319,00

DWB160N100-4DFT 100 50 30 20 12318243 2319,00

DWB160N125-4DFT 125 50 30 20 12318246 2419,00

DWB160N160-4DFT 160 50 30 20 12318247 2419,00

Moulded Case Circuit-Breakers - DWB Distribution - 4-Pole - Neutral

Not Protected

ADJUSTABLE THERMAL AND FIXED MAGNETIC RELEASES - DWB250-D

LOW BREAKING CAPACITY DWB250B - 4-POLE

NORMAL BREAKING CAPACITY DWB250N - 4-POLE

TYPE In (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWB250B100-4DF 80...100 42 16 15 12318906 3565,00

DWB250B125-4DF 100...125 42 16 15 12318907 3565,00

DWB250B160-4DF 125...160 42 16 15 12318948 3565,00

DWB250B200-4DF 160...200 42 16 15 12318949 3788,00

DWB250B250-4DF 200...250 42 16 15 12318950 3788,00

TYPE In (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWB250N100-4DF 80...100 85 35 30 12319489 3925,00

DWB250N125-4DF 100...125 85 35 30 12319490 3925,00

DWB250N160-4DF 125...160 85 35 30 12319491 3925,00

DWB250N200-4DF 160...200 85 35 30 12319492 4174,00

DWB250N250-4DF 200...250 85 35 30 12319493 4174,00

Page 122: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

240 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 241

Moulded Case Circuit-Breakers - DWB Distribution - 4-Pole - Neutral

Protected - 50%

ADJUSTABLE THERMAL AND FIXED MAGNETIC RELEASES - DWB250-D

LOW BREAKING CAPACITY DWB250B - 4-POLE

NORMAL BREAKING CAPACITY DWB250N - 4-POLE

TYPE In (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWB250B160-4DFP 125...160 42 16 15 12318951 3565,00

DWB250B200-4DFP 160...200 42 16 15 12318952 3788,00

DWB250B250-4DFP 200...250 42 16 15 12318953 3788,00

TYPE In (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWB250N160-4DFP 125...160 85 35 30 12319495 3925,00

DWB250N200-4DFP 160...200 85 35 30 12319496 4174,00

DWB250N250-4DFP 200...250 85 35 30 12319497 4174,00

Moulded Case Circuit-Breakers - DWB Distribution - 4-Pole - Neutral

Protected - 100%

ADJUSTABLE THERMAL AND FIXED MAGNETIC RELEASES - DWB250-D

LOW BREAKING CAPACITY DWB250B - 4-POLE

NORMAL BREAKING CAPACITY DWB250N - 4-POLE

TYPE In (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWB250B100-4DFT 80...100 42 16 15 12318954 3565,00

DWB250B125-4DFT 100...125 42 16 15 12318955 3565,00

DWB250B160-4DFT 125...160 42 16 15 12318956 3565,00

DWB250B200-4DFT 160...200 42 16 15 12318957 3788,00

DWB250B250-4DFT 200...250 42 16 15 12318958 3788,00

TYPE In (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWB250N100-4DFT 80...100 85 35 30 12319508 3925,00

DWB250N125-4DFT 100...125 85 35 30 12319509 3925,00

DWB250N160-4DFT 125...160 85 35 30 12319510 3925,00

DWB250N200-4DFT 160...200 85 35 30 12319511 4174,00

DWB250N250-4DFT 200...250 85 35 30 12319512 4174,00

Page 123: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

242 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 243

Moulded Case Circuit-Breakers - DWB Distribution - 4-Pole - Neutral

Not Protected

ADJUSTABLE THERMAL AND MAGNETIC RELEASES - DWB400-D

NORMAL BREAKING CAPACITY DWB400N - 4-POLE

HIGH BREAKING CAPACITY DWB400H - 4-POLE

TYPE Ir (A) I

m (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWB400N200-4DA 160...200 1000...2000 65 35 35 12534010 6512,00

DWB400N250-4DA 200...250 1250...2500 65 35 35 12534011 6512,00

DWB400N320-4DA 250...320 1600...3200 65 35 35 12534012 7442,00

DWB400N400-4DA 320...400 2000...4000 65 35 35 12534013 7442,00

TYPE Ir (A) I

m (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWB400H200-4DA 160...200 1000...2000 80 65 65 12534068 7442,00

DWB400H250-4DA 200...250 1250...2500 80 65 65 12534069 7442,00

DWB400H320-4DA 250...320 1600...3200 80 65 65 12534070 8000,00

DWB400H400-4DA 320...400 2000...4000 80 65 65 12534071 8000,00

Moulded Case Circuit-Breakers - DWA Distribution - 4-Pole - Neutral

Not Protected

ADJUSTABLE THERMAL AND MAGNETIC RELEASES - DWA800

NORMAL BREAKING CAPACITY DWA800N - 4-POLE

HIGH BREAKING CAPACITY DWA800H - 4-POLE

TYPE Ir (A) I

m (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWA800N-320-4 225...320 1600...3200 65 35 35 10318016 16488,00

DWA800N-400-4 280...400 2000...4000 65 35 35 10318015 16488,00

DWA800N-500-4 350...500 2500...5000 65 35 35 11641949 16488,00

DWA800N-630-4 440...630 3150...6300 65 35 35 10074349 16488,00

DWA800N-800-4 560...800 3200...6400 65 35 35 10074350 23774,00

TYPE Ir (A) I

m (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWA800H-320-4 225...320 1600...3200 80 65 65 11650421 17068,00

DWA800H-400-4 280...400 2000...4000 80 65 65 10306809 17068,00

DWA800H-500-4 350...500 2500...5000 80 65 65 11641951 17068,00

DWA800H-630-4 440...630 3150...6300 80 65 65 11641952 17068,00

DWA800H-800-4 560...800 3200...6400 80 65 65 11641953 25601,00

Page 124: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

244 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 245

Moulded Case Circuit-Breakers - DWA Distribution and Generator

Protection - 4-Pole

ELECTRONIC TRIP UNIT LSI - DWA1600-E

NORMAL BREAKING CAPACITY DWA1600S - 4-POLE

HIGH BREAKING CAPACITY DWA1600H - 4-POLE

TYPE Ir (A) I

m (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWA1600S-E1250-4 500...1250 6250...12500 80 50 50 12736311 31589,00

DWA1600S-E1600-4 640...1600 8000...16000 80 50 50 12524259 38228,00

TYPE Ir (A) I

m (A)

IEC60947-2 - Icu

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440 V

DWA1600H-E1250-4 500...1250 6250...12500 100 65 65 12736312 35250,00

DWA1600H-E1600-4 640...1600 8000...16000 100 65 65 12524258 40240,00

Switch Disconnectors - IWB - 4-Pole

Switch Disconnectors - IWA - 4-Pole

TYPE Ln (A) FRAME SIZE STOCK CODE

PRICE EACH

(ZAR)

IWB160-160-4XX 160 DWB160 12652603 1849,00

IWB250-250-4XX 250 DWB250 12652606 2719,00

IWB400-250-4XX 250 DWB400 12533965 5581,00

IWB400-400-4XX 400 DWB400 12533963 6261,00

TYPE Ln (A) FRAME SIZE STOCK CODE

PRICE EACH

(ZAR)

IWA800-630-4 630 DWA800 11774967 1500,00

IWA800-800-4 800 DWA800 11775038 21210,00

IWA1600-1000-4 1000 DWA1600 11851560 32136,00

IWA1600-1250-4 1250 DWA1600 12736313 35350,00

IWA1600-1600-4 1600 DWA1600 12736315 37706,00

Note : IWB/IWA use the same accessories of DWB/DWA ranges.

Page 125: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

246 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 247

ACCESSORIES OF DWB160

Accessories

1 - MCCB DWB160

2 - Auxiliary contact block BC, alarm block AL,

alarm/contact block BCAL

3 - Undervoltage release BS, shunt release BD

4 - DIN rail base BFR DWB160 3P

5 - Phase barriers of DWB160 (line side supplied as

standard, load side supplied as optional)

6 - 90° connection extension bars CT DWB160 3P

7 - Straight extension bars BE DWB160 3P (terminal tabs)

8 - Escutcheon MP DWB160

9 - Mechanical interlock BLIM DWB160 3P

10 - Padlocking device PL DWB160 3P

11 - Panel door rotary operating handle MRX

12 - Panel door rotary operating handle MR

13 - Terminal lugs (supplied as standard)

32

1

4

5

67

13

12

118 9

10

3

Note: 2 and 4-pole DWBs use the same accessories of 3-pole DWBs.

ACCESSORIES OF DWB250

Accessories

1 - MCCB DWB250

2 - Auxiliary contact block BC, alarm block AL,

alarm/contact block BCAL

3 - Undervoltage release BS, shunt release BD

4 - DIN rail base BFR DWB250 3P

5 - Terminal lugs PC DWB250 3P

6 - 90° connection extension bars CT DWB250 3P

7 - Straight extension bars BE DWB250 3P (terminal tabs)

8 - Phase barriers of DWB250

(supplied as standard and as an accessory)

9 - Escutcheon MP DWB250

10 - Mechanical interlock BLIM DWB250 3P

11 - Padlocking device PL DWB250

12 - Panel door rotary operating handle MR

3

1

2

4

5

6

7

8

12

9 10

11

3

Note: 2 and 4-pole DWBs use the same accessories of 3-pole DWBs.

Page 126: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

248 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 249

ACCESSORIES OF DWB400

Accessories

1 - MCCB DWB400

2 - Round cable terminals PC DWB400 3P (lugs)

3 - Straight extension bars BE DWB400 3P (terminal tabs)

4 - Padlocking device PL DWB400

5 - Motor operator AM DWB400

6 - Mechanical interlock BLIM DWB400

7 - Direct rotary handle MRI DWB400

8 - Escutcheon MP DWB400

9 - Panel door rotary operating handle MR DWB400

10 - Phase barriers of DWB400 (supplied as standard and as an accessory)

11 - Auxiliary contact block BC, alarm block AL, alarm/contact block BCAL

12 - Undervoltage release BS, shunt release BD

C DWB400 3P (l

2

1

3

10

4

6

8 9

7

5

10

Note: 2 and 4-pole DWBs use the same accessories of 3-pole DWBs.

1211

12

ACCESSORIES OF DWA800 AND 1600

Accessories

1 - MCCB DWA800

2 - MCCB DWA1600

3 - Round cable terminals PC DWA800 (lugs)

4 - Round cable terminals PC DWA1600 (lugs)

5 - Straight extension bars BE DWA800 (terminal tabs)

6 - Straight extension bars BE DWA1600 (terminal tabs)

7 - Padlocking device PLW800-1600

8 - Direct rotary handle MRI DWA800 or MRI DWA1600

9 - Mechanical interlock BLIM DWA800-1600

10 - Escutcheon MP DWA800-1600

11 - Panel door rotary operating handle MR DWA800 or MR DWA1600

3

1

5

7

9

10

11

8

6

2

4

Page 127: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

250 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 251

Internal Accessories

BC AUXILIARY CONTACT BLOCK

Indicates the main contacts status open/closed (ON/OFF)

through a changeover contact (1 SPDT)

AL ALARM CONTACT BLOCK

Indicates circuit breakers trip due to overload or

short-circuit condition through a changeover contact (1SPDT)

BCAL

Ensemble comprised of an auxiliary contact block + alarm

contact block. The BCAL block makes both functions

described above

Internal accessoryNumber of

contacts

Reference code

DWB160 DWB250 DWB400 DWA8001) DWA16001)

Auxiliary contact

block BC

1 changeover BC-1 DWB

BC-2 DWB

-

BC-1 DWA800

BC-2 DWA800

BC-3 DWA800

BC-1 DWA1600

BC-2 DWA1600

BC-3 DWA1600

2 changeover

3 changeover

Alarm contact

block AL1 changeover AL-1 DWB AL-1 DWA800-1600

Auxiliary contact and

alarm block BCAL

1BC + 1AL BCAL-2 DWB

-

BCAL-2 DWA800

BCAL-3 DWA800

BCAL-2 DWA1600

BCAL-3 DWA16002BC + 1AL

Electrical characteristics

Rated voltage Type of load Switching capacity ²) (A)

125 V acResistive 6

353

1512

1512Inductive

250 V acResistive 6

332

1512

1512Inductive

125 V dcResistive 0.4

0.20.40.2

0.60.6

0.60.6Inductive

250 V dcResistive 0.2

0.20.20.2

0.30.3

0.30.3Inductive

Notes: 1) Use BCAL blocks when applications require auxiliary contact block and alarm block fitted in the same circuit breaker.

2) Not applicable for motor switching.

AUXILIARY CONTACT AND ALARM CONTACT BLOCKS

The auxiliary contact and alarm blocks have the function to signal remotely the status of circuit breakers power contacts.

There are 3 types of contact blocks available:

USING BC AND AL BLOCKS

BC, AL and BCAL blocks already come with built-in terminal blocks. These terminal blocks accept wires of 0.5 to 1.5 mm²

(20 to 16 AWG) and tightening torque of 0.8 Nm (6.9 lb. inch).

WIRING DIAGRAMS

ON OFF TRIP

BC

AL

11

12

22

14

24

21

81

82

84

11

12

22

14

24

21

81

82

84

Reference code

Rated voltage (Ue) Voltage code DWB160 / DWB250 Consumption DWB400 DWA800 DWA1600 Consumption

BS undervoltage

release

110/127 V ac D60 BS DWB400 D60 BS D60 DWA800 BS D60 DWA1600 5 VA

220/240 V ac D66 BS DWB400 D66 BS D66 DWA800 BS D66 DWA1600 5 VA

380-415 V ac D70 BS DWB400 D70 BS D70 DWA800 BS D70 DWA1600 5 VA

440-480 V ac D74 BS DWB400 D74 BS D74 DWA800 BS D74 DWA1600 5 VA

24 V dc C03 BS DWB400 C03 BS C03 DWA800 BS C03 DWA1600 1 W

48 V dc C07 BS DWB400 C07 BS C07 DWA800 BS C07 DWA1600 1 W

125 V dc C13 BS C13 DWA800 BS C13 DWA1600 4 W

24 V ac / V dc E26 BS DWB160-250 E26 1.5 VA

48 V ac / V dc E27 BS DWB160-250 E27 1.5 VA

60 V ac / V dc E28 BS DWB160-250 E28 1.5 VA

110/130 V ac / V dc E10 BS DWB160-250 E10 1.5 VA

220/250 V ac / V dc E15 BS DWB160-250 E15 1.5 VA

BD shunt release

24 V ac / V dc E26 BD DWB160-250 E26 150 VA BD DWB400 E26 BD E26 DWA800 BD E26 DWA1600 65 VA

48 V ac / V dc E27 BD DWB160-250 E27 150 VA BD DWB400 E27 BD E27 DWA800 BD E27 DWA1600 65 VA

60 V ac / V dc E28 BD DWB160-250 E28 150 VA

110/130 V ac / V dc E10 BD DWB160-250 E10 150 VA BD DWB400 E10 BD E10 DWA800 BD E10 DWA1600 65 VA

220/250 V ac / V dc E15 BD DWB160-250 E15 150 VA BD DWB400 E15 BD E15 DWA800 BD E15 DWA1600 65 VA

Internal Accessories

SHUNT AND UNDERVOLTAGE RELEASES

Voltage releases function to trip remotely the circuit breaker. They are often used for remote emergency stop purpose.

BD SHUNT RELEASE

When energized by a pulse or maintained signal of voltage,

the shunt release trips the circuit breaker (trip position).

The shunt release works from 70 to 110% of the rated

voltage (0.70 x Un < Ue < 1.10 x Un)

This release features a device to keep it not energized after

the tripping pulse

BS UNDERVOLTAGE RELEASE

Trips the circuit breaker when the voltage drops below 35%

of the rated voltage (Ue < 0.35 x Un)

When voltage is between 35 to 70% of the rate voltage, it

may open the circuit breaker (0.35 x Un < Ue < 0.7 x Un)

After the operation of BS release, circuit breaker can only

be closed if supply voltage is above 85% of the rated

voltage (Ue > 0.85 x Un)

The BS undervoltage release along with an emergency

stop push button makes possible the fail-safe operation of

the circuit breaker

USING BD AND BS RELEASES

BD and BS releases already come with built-in terminal

blocks. These terminal blocks accept wires of 0.5 to 1.5 mm²

(20 to 16 AWG) and tightening torque of 0.8 Nm (6.9 lb.inch).

After BD or BS releases have operated, the circuit breaker

have to be reset before being closed again.

WIRING DIAGRAMS

D1

BS

D2

C1

C2

BD

POSSIBLE CONFIGURATIONS OF INTERNAL ACCESSORIES

Internal accessory DWB160 DWB250 DWB400 DWA800 DWA1600

Auxiliary contact 2 1 2 1 2 1 2 1 2 1 2 1 3 3 3 3

Alarm contact 0 1 0 1 0 1 0 1 0 1 0 1 1 1 1 1

Shunt release 1 1 0 0 1 1 0 0 1 1 0 0 1 0 1 0

Undervoltage release 0 0 1 1 0 0 1 1 0 0 1 1 0 1 0 1

C1 D1

BD BS

C2 D2

Page 128: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

252 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 253

External Accessories

PANEL DOOR ROTARY OPERATING HANDLES

The MR rotary handles allow external operation of a circuit breaker installed in a electrical panel. WEG has 2 options to better fit

according to customer needs.

MR

Degree of protection IP55

When in ON position, panel door cannot be opened, unless

a tool is used to bypass the panel door locking system,

allowing thermometry of the panel

Circuit breaker and panel door padlocking in OFF position

using 1 to 3 padlocks. MR allows padlocks with diameters

of Ø5...8 mm

Handle shaft length can be adjusted up to 465 mm

Available in 2 color versions: black handle/grey background

and red handle/yellow background

MRX

Higher degree of protection IP66

When in ON position, panel door cannot be opened, unless

a tool is used to bypass the panel door locking system,

allowing thermometry of the panel

Circuit breaker and panel door padlocking in OFF position

using 1 to 3 padlocks. MRX allows padlocks with diameters

of Ø4…8 mm

Handle shaft length can be adjusted up to 130 mm

Available in 2 color versions: black handle/grey background

and red handle/yellow background

Note: 1) DWB160 handle length of 45 mm / DWB250 and DWB400: handle length of 80 mm.

Rotary

operating

handle

Thermometry

feature

Degree of

protection

Shaft

length

(mm)

Handle

length

(mm)

Handle color /

background

color

Reference code

DWB160 DWB250 DWB400 DWA800 DWA1600

MR Yes IP55

130 45 / 801)Black / grey MR DWB160 130 MR DWB250 130 MR DWB400 130

Red / yellow MR DWB160 130 E MR DWB250 130 E MR DWB400 130 E

166 125Black / grey MR166 DWA800 MR166 DWA1600

Red / yellow MR166E DWA800 MR166E DWA1600

430 45 / 801)Black / grey MR DWB160 430 MR DWB250 430 MR DWB400 430

Red / yellow MR DWB160 430 E MR DWB250 430 E MR DWB400 430 E

465 125Black / grey MR465 DWA800 MR465 DWA1600

Red / yellow MR465E DWA800 MR465E DWA1600

MRX Yes IP66

130 -Black / grey MRX DWB160 130

Red / yellow MRX DWB160 130 E

430 -Black / grey MRX DWB160 430

Red / yellow MRX DWB160 430 E

External Accessories

Direct rotary

operating handleThermometry feature Degree of protection

Handle color/

Background color

Reference code

DWB400 DWA800 DWA1600

MRI No IP20 Black/Gray MRI DWB400 MRI DWA800 MRI DWA1600

DIRECT ROTARY OPERATING HANDLES

The MRI direct rotary handles allow direct and rotary operation of circuit breakers.

MRI

Degree of protection IP20

Padlocking in OFF position using 1 to 3 padlocks

MOTOR OPERATOR

The AM motor operator makes possible complete remote operation of 400 A circuit breakers or switch-disconnectors.

AM

Remote operation device

Automatic and manual selection through front switch

In automatic operation, the switching on and off control is done by electrical

signals using pushbuttons. The maximum operation frequency is 60 operations/

hour

In manual operation, the AM motor operator can be only used locally using the

switching lever

After installing the AM device, the status of the circuit breaker is shown on the

front of the motor operator

Besides using the circuit breaker + AM operator for remote switching of motors

and electrical circuits, the configuration of 2 x MCCB+AM creates an automatic

changeover system (see CTM topic)

The AM motor operator can be used in 3-pole and 4-pole 400 A frame size

circuit breakers

External accessory Rated voltage - Ue Consumption (W)Reference code

DWB400

Motor operator AM

24 V dc 10 AM DWB400 C03

48-60 V dc 10 AM DWB400 C25

110 V ac /dc 10 AM DWB400 E51

230 V ac / 220 V dc 10 AM DWB400 E46

Note: Other voltages upon request.

USING AM MOTOR OPERATOR

AM device already comes with built-in terminal blocks. These terminal blocks accept tightening torque of 1.2 Nm (12.2 kgf.cm).

WIRING DIAGRAMS

S1 S2 S3

Ue ON OFF

Page 129: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

254 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 255

External Accessories

CHANGEOVER DEVICES

Manual-operated or automatic changeovers are used to make safe switching of two different circuits.

External accessory MCCB Reference code

Mechanical interlock BLIM

DWB160 3P BLIM DWB160 3P

DWB160 4P BLIM DWB160 4P

DWB250 3P BLIM DWB250 3P

DWB250 4P BLIM DWB250 4P

DWB400 3P BLIM DWB400 3P

DWB400 4P BLIM DWB400 4P

DWA800 3P / DWA1600 3P BLIM DWA800-1600

DWA800 4P / DWA1600 4P BLIM DWA800-1600 4P

BLIM MECHANICAL INTERLOCK

Provides safe operation in a manual-operated changeover system

Makes the mechanical interlock of 2 circuit breakers of the same frame size, preventing both MCCBs to be in ON position at

the same time

It can be padlocked in 2 positions: MCCB1 ON and MCCB2 OFF, MCCB1 OFF and MCCB2 ON

BLIM allows padlocks with diameters of Ø4...8 mm

For DWB160 and DWB250, it is possible to interlock

3 MCCBs side-by-side using 2 BLIMs

Also available for 4-pole circuit breakers

CTM AUTOMATIC CHANGEOVER

The most widely used changeover system, no human-interference is required

Remote operation is made by AM motor operators

The changeover system may be built between 2 MCCBs, 2 switch-disconnectors or 1 MCCB and 1 switch-disconnector

The CTM ensemble is also comprised 2 AM motor operators + 2 BC2 contact blocks + mounting plate + rear mechanical

interlock device

To prevent erroneous manual operation in case of a electrical fault, the CTM features the mechanical interlock

Type of protection Reference

Circuit breaker /

Switch-disconnector

left

Circuit breaker /

Switch-disconnector

right

24 V dc 110 V ac/dc 230 V ac/ 220 V dc

Distribution Generator CTM400- DA GA3P-C03-2000 CTM400- DA GA3P-E51-2000 CTM400- DA GA3P-E46-2000

Distribution None¹) CTM400- DA I3P-C03-2000 CTM400- DA I3P-E51-2000 CTM400- DA I3P-E46-2000

Distribution Distribution CTM400- DA DA3P-C03-2000 CTM400- DA DA3P-E51-2000 CTM400- DA DA3P-E46-2000

None¹) None¹) CTM400- I I3P-C03-2000 CTM400- I I3P-E51-2000 CTM400- I I3P-E46-2000

Generator Generator CTM400- GA GA3P-C03-2000 CTM400- GA GA3P-E51-2000 CTM400- GA GA3P-E46-2000

Generator None¹ CTM400- GA I3P-C03-2000 CTM400- GA I3P-E51-2000 CTM400- GA I3P-E46-2000

PRODUCT SELECTION

Note: 1) The rated currents available for switch-disconnectors (without trip unit) are 250 or 400 A.

Replace by Short-circuit breaking capacity 380/415 V ac

N 35 kA

H 65 kA

Replace by Rated current

200 160...200

250¹) 200...250

320 250...320

400¹) 320...400

External Accessories

ACCESSORIES FOR CONNECTION AND INSTALLATION

Depending on the application and local standards, the MCCB may be installed in several positions in a panel and connected

through busbars or cables. Given these requirements, the DWA and DWB range of circuit breakers have the specific

connection accessories to comply with.

External accessory MCCB Supplied with (units) Maximum cross-section (mm²) Reference code

Straight extension busbar BE

DWB160 3P 3

See installation and connections

on page 217.

BE DWB160 3P

DWB160 4P 4 BE DWB160 4P

DWB250 3P 3 BE DWB250 3P

DWB250 4P 4 BE DWB250 4P

DWB400 3P 3 BE DWB400 3P

DWB400 4P 4 BE DWB400 4P

DWA800 3P 3 BE DWA800

DWA800 4P 4 BE DWA800-4P

DWA1600 3P (up to 1250 A) 3 BE DWA1600-1250

DWA1600 4P (up to 1250 A) 4 BE DWA1600-1250-4P

DWA1600 3 BE DWA1600

DWA1600-4P 4 BE DWA1600-4P

90° extension bar CT

DWB160 3P 3

See installation and connections

on page 217.

CT DWB160 3P

DWB160 4P 4 CT DWB160 4P

DWB250 3P 3 CT DWB250 3P

DWB250 4P 4 CT DWB250 4P

DWB400 3P 3 CT DWB400 3P

DWB400 4P 4 CT DWB400 4P

DWA800 3P / 4P 3 CT DWA800

DWA1600 3P / 4P 3 CT DWA1600

Round cable terminal PC

DWB250 3P 3 120 (1 cable) PC DWB250 3P

DWB250 4P 4 120 (1 cable) PC DWB250 4P

DWB400 3P 3 240 (1 cable) PC DWB400 3P

DWB400 4P 4 240 (1 cable) PC DWB400 4P

DWA800 3P / 4P 3 240 (2 cables) PC DWA800

DWA1600 3P / 4P 3 240 (4 cables) PC DWA1600

DIN rail base BFR1)DWB160 3P 1 N/A BFR DWB160

DWB250 3P 1 N/A BFR DWB250

BE STRAIGHT EXTENSION BARS (TERMINAL TABS)

Extends the MCCB busbars for connection using busbars or

cables with ring terminals

Also available for 4-pole circuit breakers

CT 90° EXTENSION BARS (TERMINAL TABS)

Allows direct connection using busbars or cables from

the back side of the MCCB

CT is supplied with 3 pieces

Also available for 4-pole circuit breakers

PC ROUND CABLE TERMINALS (LUGS)

Allows the MCCB for connection using cables

PC is supplied with 3 pieces

Also available for 4-pole circuit breakers Built-in for DWB160 models

BFR DIN RAIL BASE

Quick assembly of DWB160 and DWB250 on 35 mm DIN rails

Fast replacement when panel is under maintenance

Note: 1) Only for DWB160B, DWB160N, DWB250B and DWB250N.

Page 130: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

256 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 257

External Accessories

MP ESCUTCHEONS Escutcheons are frames for cutouts in panel doors It makes possible the external switching of the MCCB through the front door

when the circuit breakers is installed close to the panel door, maintaining the

degree of protection Degree of protection IP40 See section Dimensions for cutout details

ESCUTCHEONS, PADLOCKING DEVICES AND PHASE BARRIERS

External accessory MCCB Reference code

Escutcheon MP

DWB160 3P / 4P MP DWB160

DWB250 3P / 4P MP DWB250

DWB400 3P / 4P MP DWB400

DWA800 / DWA1600 - 3P / 4P MP DWA800-1600

External accessory MCCB SUPPLIED WITH (UNITS) Reference code

Phase Barrier PB

DWB160 3P / DWB250 3P 2 PB DWB160-250 3P

DWB160 4P / DWB250 4P 3 PB DWB160-250 4P

DWB400 3P 2 PB DWB400 3P

DWB400 4P 3 PB DWB400 4P

External accessory MCCB Reference code

Padlocking device PLW

DWA160 4P PL DWB160 3P

DWB160 3P PL DWB160 4P

DWB250 3P / 4P PL DWB250

DWB400 3P / 4P PL DWB400

DWA800 / DWA1600 - 3P / 4P PLW800-1600

PLW PADLOCKING DEVICE The PLW is a fixed-type device that is installed on the front of the MCCB

ensuring the MCCB locking in OFF position It can be padlocked using 1 to 3 padlocks. PLW allows padlocks with

diameters of Ø4...8 mm

PB PHASE BARRIERS The circuit breakers are supplied with phase barriers for the line side, but

depending on the application, additional phase barriers are required on the

load side (see page 265)

Accessories for Moulded Case Circuit-Breakers DWB

TYPE CONTACT CIRCUIT-BREAKER STOCK CODEPRICE EACH

(ZAR)

BC-1 DWB 1NO/NC DWB160 / DWB250 / DWB400 - 3P / 4P 10848664 597,00

BC-2 DWB 2NO/NC DWB160 / DWB250 / DWB400 - 3P / 4P 11026395 746,00

TYPE CONTACT CIRCUIT-BREAKER STOCK CODEPRICE EACH

(ZAR)

AL-1 DWB 1NO/NC DWB160 / DWB250 / DWB400 - 3P / 4P 11026397 522,00

TYPE CONTACT CIRCUIT-BREAKER STOCK CODEPRICE EACH

(ZAR)

BCAL-2 DWB 1NO/NC (BC) + 1NO/NC (AL) DWB160 / DWB250 / DWB400 - 3P / 4P 11026396 1342,00

INTERNAL ACCESSORIES

AUXILIARY CONTACT

ALARM CONTACT

AUXILIARY CONTACT + ALARM CONTACT

Page 131: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

258 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 259

Accessories for Moulded Case Circuit-Breakers DWB

INTERNAL ACCESSORIES

UNDERVOLTAGE RELEASE

SHUNT TRIP

TYPE CIRCUIT-BREAKER

STOCK CODE 50/60 Hz

PRICE EACH (ZAR)

E26 (24 V) E27 (48 V) E10 (110-130 V) E15 (220-250 V)

BS DWB160-250 DWB160 / DWB250 - 3P / 4P 11338330 11338318 11338324 10853866 969,00

TYPE CIRCUIT-BREAKER

STOCK CODE 50/60 HzPRICE EACH

(ZAR)E26 (24 V) E27 (48 V) E10 (110-130 V) E15 (220-250 V)

BD DWB160-250 DWB160 / DWB250 - 3P / 4P 11338271 11338248 11338254 10850989 895,00

BD DWB400 DWB400 - 3P / 4P 12687485 12687486 12687482 12687483 1090,00

TYPE CIRCUIT-BREAKER

STOCK CODE 50/60 HzPRICE EACH

(ZAR)E26 (24 V) E27 (48 V) E10 (110-130 V) E15 (220-250 V)

BS DWB400 DWB400 3P / 4P 12687427 12687479 12687480 12687481 1136,00

TYPE CIRCUIT-BREAKER

STOCK CODE 50/60 HzPRICE EACH

(ZAR)C02 (12 V) C03 (24 V) C07 (48 V) C13 (125 V)

BS DWB400 DWB400 3P / 4P 12687424 12687425 12687426 Upon Request 2) 1136,00

Note: 1) Accessories supplied separately from circuit-breaker.

2) Availability upon request.

Article numbers for other rated voltages and frequencies upon request.

3P means 3-Pole MCCB. / 4P means 4-Pole MCCB.

Accessories for Moulded Case Circuit-Breakers DWA

INTERNAL ACCESSORIES

AUXILIARY CONTACT

AUXILIARY CONTACT + ALARM CONTACT

UNDERVOLTAGE RELEASE

SHUNT TRIP

ALARM CONTACT

Note: It is not possible to install both BC and AL blocks individually into the circuit-breaker. Consider using BCAL blocks below.

TYPE CONTACT CIRCUIT-BREAKER STOCK CODEPRICE EACH

(ZAR)

BC-1 DWA800 1NO/NC / 1NA/NC DWA800 3P / 4P 10046753 645,00

BC-1 DWA1600 1NO/NC / 1NA/NC DWA1600 3P / 4P 10046832 645,00

BC-2 DWA800 2NO/NC / 2NA/NC DWA800 3P / 4P 10046748 979,00

BC-2 DWA1600 2NO/NC / 2NA/NC DWA1600 3P / 4P 10046833 979,00

BC-3 DWA800 3NO/NC / 3NA/NC DWA800 3P / 4P 10046754 1182,00

BC-3 DWA1600 3NO/NC / 3NA/NC DWA1600 3P / 4P 10046834 1182,00

TYPE CONTACT CIRCUIT-BREAKER STOCK CODEPRICE EACH

(ZAR)

BCAL-2 DWA800 1NO/NC (BC) + 1NO/NC (AL) DWA800 3P / 4P 11648560 2409,00

BCAL-3 DWA800 2NO/NC (BC) + 1NO/NC (AL) DWA800 3P / 4P 11648786 3361,00

BCAL-2 DWA1600 1NO/NC (BC) + 1NO/NC (AL) DWA1600 3P / 4P 11648561 2409,00

BCAL-3 DWA1600 2NO/NC (BC) + 1NO/NC (AL) DWA1600 3P / 4P 11648787 3361,00

TYPE CONTACT CIRCUIT-BREAKER STOCK CODEPRICE EACH

(ZAR)

AL-1 DWA800-1600 1NO/NC / 1NA/NC DWA800 / DWA1600 - 3P / 4P 10186511 693,00

TYPE CIRCUIT-BREAKER

STOCK CODE 50/60 HzPRICE EACH

(ZAR)E26 (24 V) E27 (48 V) E10 (110-130 V) E15 (220-250 V)

BD DWA800 DWA800 3P / 4P 10046772 10046773 10046856 10046775 1090,00

BD DWA1600 DWA1600 3P / 4P 10046782 10046783 10046725 10046724 1090,00

TYPE CIRCUIT-BREAKER

STOCK CODE 50/60 HzPRICE EACH

(ZAR)D60

(110-127 V)

D66

(220-240 V)

D70

(380-415 V)

D74

(440-480 V)

BS DWA800 DWA800 3P / 4P 10046779 10186518 10074745 10046780 1194,00

BS DWA1600 DWA1600 3P / 4P 10046787 10046727 10046726 10046762 1194,00

TYPE CIRCUIT-BREAKER

STOCK CODE 50/60 HzPRICE EACH

(ZAR)C03 (24 V) C07 (48 V) C13 (125 V)

BS DWA800 DWA800 3P / 4P 10046777 10046778 10046797 1194,00

BS DWA1600 DWA1600 3P / 4P 10046785 10046786 10212462 1194,00

Page 132: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

260 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 261

Accessories for Moulded Case Circuit-Breakers DWA & DWB

EXTERNAL ACCESSORIES 1)

PHASE BARRIERS

ESCUTCHEONS

90° EXTENSION BARS (OR TERMINAL TAGS) 1)

TYPE CIRCUIT-BREAKER STOCK CODEPRICE EACH

(ZAR)

PB DWB160-250 3P DWB160 3P / DWB250 3P 12403111 60,00

PB DWB160-250 4P DWB160 4P / DWB250 4P 12403112 90,00

PB DWB400 3P DWB400 3P 12731651 66,00

PB DWB400 4P DWB400 4P 12731653 99,00

TYPE CIRCUIT-BREAKER STOCK CODEPRICE EACH

(ZAR)

MP DWB160 DWB160 3P 11338525 26,00

MP DWB250 DWB250 3P 11338526 26,00

MP DWB400 DWB400 3P / 4P 10046728 45,00

MP DWA800-1600 DWA800 / DWA1600 - 3P / 4P 10186520 45,00

TYPE CIRCUIT-BREAKER STOCK CODEPRICE EACH

(ZAR)

CT DWB160 3P DWB160 3P / 4P 10046937 310,00

CT DWB250 3P DWB250 3P / 4P 12288234 Under request 2)

CT DWB400 3P DWB400 3P / 4P 10074749 3017,00

CT DWA800 DWA800 3P / 4P 10186521 3720,00

CT DWA1600 DWA1600 3P / 4P 10046808 6211,00

Note : 3P - 2 pieces for line or load side.

4P - 3 pieces for line or load side.

Note : 1) DWB: Accessories supplied separately from circuit-breaker.

DWA: Accessories supplied only factory-assembled in the circuit-breaker.

2) Upon Request.

Accessories for Moulded Case Circuit-Breakers DWA & DWB

EXTERNAL ACCESSORIES 1)

STRAIGHT EXTENSION BARS (OR TERMINAL TAGS)

ROUND CABLE TERMINAL (OR LUGS)

TYPE CIRCUIT-BREAKER PACKED QUANTITY STOCK CODEPRICE EACH

(ZAR)

BE DWB160 3P DWB160 3P 3 11279346 394,00

BE DWB160 4P DWB160 4P 4 11780009 1394,00

BE DWB250 3P DWB250 3P 3 11279347 787,00

BE DWB250 4P DWB250 4P 4 12714046 973,00

BE DWB400 3P DWB400 3P 3 10187721 1112,00

BE DWB400 4P DWB400 4P 4 11780016 5181,00

BE DWA800 DWA800 3P 3 10046552 4142,00

BE DWA800-4P DWA800 4P 4 11780012 5410,00

BE DWA1600-1250 DWA1600 (up to / hasta 1250 A) 3P 3 10186451 4321,00

BE DWA1600-1250-4P DWA1600 (up to / hasta 1250 A) 4P 4 11780173 10050,00

BE DWA1600 DWA1600 3P 3 10046553 8031,00

BE DWA1600-4P DWA1600 4P 4 11780050 10050,00

TYPE CIRCUIT-BREAKER PACKED QUANTITY STOCK CODEPRICE EACH

(ZAR)

PC DWB250 3P DWB250 3P 3 11277469 522,00

PC DWB250 4P DWB250 4P 4 Under request 2) Upon request

PC DWB400 3P DWB400 3P 3 10046554 729,00

PC DWB400 4P DWB400 4P 4 Under request 2) Upon request

PC DWA800 DWA800 3P 3 10186433 1133,00

PC DWA1600 DWA1600 3P 3 10046555 1239,00

Note : 1) DWB: Accessories supplied separately from circuit-breaker.

DWA: Accessories supplied only factory-assembled in the circuit-breaker.

2) Upon Request.

Page 133: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

262 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 263

Accessories for Moulded Case Circuit-Breakers DWA & DWB

EXTERNAL ACCESSORIES 1)

PANEL DOOR ROTARY OPERATING HANDLES

TYPE CIRCUIT-BREAKER HANDLE (mm) SHAFT LENGTH (mm) STOCK CODEPRICE EACH

(ZAR)

MRX DWB160 130 DWB160 3P / 4P - 130 11262341 1044,00

MRX DWB160 130 E DWB160 3P / 4P - 130 11262344 1044,00

MRX DWB160 430 DWB160 3P / 4P - 430 11262346 1267,00

MRX DWB160 430 E DWB160 3P / 4P - 430 11262368 1267,00

MR DWB160 130 DWB160 3P / 4P 45 130 10186601 1565,00

MR DWB160 130 E DWB160 3P / 4P 45 130 12249312 2296,00

MR DWB160 430 DWB160 3P / 4P 45 430 10186602 1714,00

MR DWB160 430 E DWB160 3P / 4P 45 430 12249313 2460,00

MR DWB250 130 DWB250 3P / 4P 80 130 11650006 1640,00

MR DWB250 130 E DWB250 3P / 4P 80 130 12249314 2755,00

MR DWB250 430 DWB250 3P / 4P 80 430 11650161 2087,00

MR DWB250 430 E DWB250 3P / 4P 80 430 12249315 3312,00

MR DWB400 130 DWB400 3P / 4P 80 130 10186605 1789,00

MR DWB400 130 E DWB400 3P / 4P 80 130 12249316 2869,00

MR DWB400 430 DWB400 3P / 4P 80 430 10186606 1938,00

MR DWB400 430 E DWB400 3P / 4P 80 430 12249412 3361,00

MR166 DWA800 DWA800 3P / 4P 125 166 10186512 2162,00

MR465 DWA800 DWA800 3P / 4P 125 465 10186513 2311,00

MR166 DWA1600 DWA1600 3P / 4P 125 166 10186522 2162,00

MR465 DWA1600 DWA1600 3P / 4P 125 465 10186523 2311,00

Note : 1) DWB: Accessories supplied separately from circuit-breaker.

DWA: Accessories supplied only factory-assembled in the circuit-breaker.

Accessories for Moulded Case Circuit-Breakers DWA & DWB

EXTERNAL ACCESSORIES

DIRECT ROTARY OPERATING HANDLES

DIN RAIL BASE

MECHANICAL INTERLOCK

TYPE CIRCUIT-BREAKER STOCK CODEPRICE EACH

(ZAR)

MRI DWB400 DWB400 3P / 4P 10046943 1033,00

MRI DWA800 DWA800 3P / 4P 10046794 2007,00

MRI DWA1600 DWA1600 3P / 4P 10046795 2007,00

TYPE CIRCUIT-BREAKER STOCK CODEPRICE EACH

(ZAR)

BFR DWB160 3P DWB160 3P / 4P 10046936 101,00

BFR DWB250 3P DWB250 3P / 4P 10046936 101,00

TYPE CIRCUIT-BREAKER STOCK CODEPRICE EACH

(ZAR)

BLIM DWB160 3P DWB160 3P 11639815 981,00

BLIM DWB160 4P DWB160 4P 12729994 1237,00

BLIM DWB250 3P DWB250 3P 11639817 981,00

BLIM DWB250 4P DWB250 4P 12729995 1226,00

BLIM DWB400 3P DWB400 3P 10046814 981,00

BLIM DWB400 4P DWB400 4P 11800073 1237,00

BLIM DWA800-1600 DWA800 3P / DWA1600 3P 10046798 981,00

BLIM DWA800-1600 4P DWA800 4P / DWA1600 4P 11800074 1237,00

Page 134: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

264 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 265

Accessories for Moulded Case Circuit-Breakers DWA & DWB

EXTERNAL ACCESSORIES

PADLOCKING DEVICE

MOTOR OPERATOR

AUTOMATIC CHANGEOVER

TYPE CIRCUIT-BREAKER STOCK CODEPRICE EACH

(ZAR)

PL DWB160 3P DWB160 3P 11217445 327,00

PL DWB160 4P DWB160 4P 12729993 327,00

PL DWB250 DWB250 3P 11640142 327,00

PL DWB400 DWB400 3P / 4P 11217482 564,00

PLW800-1600 DWA800 3P/4P / DWA1600 3P/4P 11640144 564,00

TYPE CIRCUIT-BREAKER

STOCK CODEPRICE EACH

(ZAR)C03 (24 V dc) C25 (48-60 V dc) E51 (110 V ac/dc)

E46 (230 V ac/

220 V dc)

AM DWB400 DWB400 10835559 10835721 10835719 10835720 9056,00

TYPE CIRCUIT-BREAKER

STOCK CODEPRICE EACH

(ZAR)C03 (24 V dc) C25 (48-60 V dc) E51 (110 V ac/dc)

E46 (230 V ac/

220 V dc)

CTM400 2x IWB / DWB400 Upon request 3) Upon request 3) Upon request 3) Upon request 3) Upon request

Note : 1) Complete unit is comprised of 2 circuit-breakers or the configuration chosen by the client + 2 motor operators + 2 BC2 + mouting plate +

mechanical interlock.

2) Price includes 2 motor operators + 2 BC2 + mounting plate + mechanical interlock. Breakers and other accessories must be added.

3) Upon Request.

- Smart code of the rated voltage.

- Fill in according to the configuration below

DG = DWB-D + DWB-G

DI = DWB-D + IWB

DD = DWB-D + DWB-D

II = IWB + IWB

GG = DWB-G + DWB-G

GI = DWB-G + IWB

Installation and Connections

MINIMUM MOUNTING DISTANCES

DW

B160

DW

B250

DW

B400

DW

A800

DW

A1600

Recommended mounting distances (mm)

A 50 50 70 100 100

B 20 20 30 30 30

C 20 20 30 30 30

Recommended distances between circuit breakers

for side by side assembly (mm)

D 10 10 0 0 0

Recommended distances between circuit breakers

for vertical assembly (mm)

E 90 150 180 200 200

Mounting position

Drilling for fixing the circuit breakers

DWB160/DWB250 DWB400/DWA800/DWA1600

F100 (DWB160B/N)

121 (DWB160L)

124 (DWB250B/N)

149 (DWB250L)199 230 265

G 25 35 35 70 70

Dimensions of fixing screw to

the plate (mm)M4x70 (2 pieces) M4x70 (2 pieces) M5x50 (4 pieces) M5x60 (4 pieces) M8x140 (4 pieces)

Surpass of the fixing screw in

relation to the circuit breaker (mm)

H 10 8 15 15 18

Tightening torque - fixing screw (Nm) 4 4 5 5 12

E E E

BB

AC

D

90°

90°

90° 90°

H

Page 135: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

266 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 267

Installation and Connections

PHASE BARRIERS, TERMINAL COVERS AND INSULATING PLATES

Notes: 1) Supplied with the moulded case circuit breaker.2) Minimum characteristic requirements of the material to be used

as insulating plate: - Dielectric strength ≥ 12 kV/mm. - Material not propagating flame. - Recommended material: phenolite, polycarbonate.3) Install as picture on the left.

W ≥ width of the circuit breaker.L ≥ length of the terminal cover or phase barrier of the circuit breaker.

Connection type

Phase barriers or terminal covers1) Insulating plates1) 2) 3)

Ue < 500 V Ue ≥ 500 V Ue < 500 V Ue ≥ 500 V

Line Load Line Load Line Load Line Load

Direct to the circuit breaker terminal

Mandatory Optional Mandatory Optional Mandatory

Using lugs

Mandatory Optional Mandatory Optional Mandatory

Using extended lugs

Mandatory Mandatory Mandatory Mandatory

Using extension bars

Mandatory Mandatory Mandatory Mandatory

H

L

Insulating plate

Insulating plate

Phase barriers or

terminals cover

Phase barriers

or terminal cover

L

Installation and Connections

THERMAL DISSIPATION

DERATINGS

Distribution MCCB

Rated current - In A 16 20 25 32 40 50 63 70 80 90 100 110 125 150 160

Power loss

W/pole

DWB160_D 1 1 2 4 4 5 8 4 5 6 7 7 10 11 12

DWB160L_D 1 1 2 4 4 6 10 5 7 9 11 12 15

Rated current - In A 100 125 160 200 250 320 400 500 630 800 1000 1250 1600

Power loss

W/pole

DWB250_D 14 19 17 14 20

DWB250L_D 17 24 25 26

DWB400_D 9 9 14 14 20 19 30

DWA800 19 30 38 47 47

DWA1600 51 96

Motor branch circuit protection MCCB

Rated current - In A 25 32 40 50 65 80 95

Power loss

W/pole

DWB160_M 2 4 4 5 6 7 7

DWB160L_M 2 4 4 6 8 9 9

Rated current - In A 80 95 105 125 150 185 200 250 320 420 500 700 800 1000

Power loss

W/pole

DWB250_M 2 3 3.5 5 7 10.5 12

DWB250L_M 4 5.5 7 9.5 13.5 21 24

DWB400_M 14 14 20 19

DWM800 32 38

DWM1600 18 21 33

Generator protection MCCB

Rated current - In A 55 75 85 105 125 140 160

Power lossW/pole

DWB160_G 7 5 6 7 10 11 12

Rated current - In A 100 125 160 200 250 320 400 500 630 800 1250 1600

Power loss

W/pole

DWB250_G 14 19 17 14 20

DWB400_G 14 20 19 30

DWG800 19 30 38 47 47

DWA1600 51 96

Switch-diconnectors

Rated current - In A 160 250 400 630 800 1000 1250 1600

Power loss

W/pole

IWB160 12

IWB250 20

IWB400 20 25

IWA800 40 40

IWA1600 33 51 96

Temperature derating 10 °C 15 °C 20 °C 25 °C 30 °C 35 °C 40 °C 45 °C 50 °C 55 °C 60 °C

DWB160 1.2 1.16 1.128 1.105 1.056 1.048 1.032 1 0.984 0.944 0.912

DWB2501.18 1.16 1.128 1.104 1.076 1.048 1.024 1 0.976 0.94 0.9

DWB400

DWA800 1.19 1.167 1.143 1.116 1.087 1.06 1.032 1 0.968 0.941 0.913

DWA1600 1.13 1.115 1.1 1.08 1.06 1.04 1.02 1 0.98 0.966 0.95

Altitude derating 2000 m 3000 m 4000 m 5000 m

Rated current - In % 100 98 93 90

Rated operational voltage - Ue V 8001) 600 500 400

Note: 1) For DWA MCCBs the rated operational voltage is 690 V.

Page 136: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

268 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 269

With a modern design, compact size and available in 4 different frames, the rated current of ACW goes

from 20 to 800 Amperes.

ACW

Ics = 100% Icu for entire

series

ELECTRICAL CIRCUIT PROTECTION MOTOR BRANCH PROTECTION

Reference In (A)

ACW100 20, 25, 32, 40, 50, 63, 80, 100

ACW160 125, 160

ACW250 200, 250

ACW400 400

ACW630 630

ACW800 800

Moulded-Case Circuit Breaker ACW

Overview

ACW100/ACW160

In 20...160 A

IcuH = 85 kA @ 380 / 415 V

IcuV = 150 kA @ 380 / 415 V Ics =

100% Icu

ACW101/ACW161/ACW250

In 20...250 A

IcuH = 85 kA @ 380 / 415 V

IcuV = 150 kA @ 380 / 415 V

Ics = 100% Icu

ACW400/ACW630

In 400/630 A

IcuH = 85 kA @ 380 / 415 V

IcuV = 150 kA @ 380 / 415 V Ics

= 100% Icu

ACW800

In 800 A

IcuH = 100 kA @ 380 / 415 V

IcuV = 150 kA @ 380 / 415 V Ics

= 100% Icu

Reference In (A)

ACW101 20, 50, 100

ACW161 160

ACW250 220

ACW400 320

ACW630 500

ACW800 630

Ics = Icu @ 220 / 240 V

ACW100H, ACW160H 100 kA

ACW100V, ACW160V 200 kA

ACW101H, ACW161H, ACW250H 120 kA

ACW101V, ACW161V, ACW250V 200 kA

ACW400H, ACW630H 120 kA

ACW400V, ACW630V 200 kA

ACW800U 120 kA

Ics = Icu @ 380 / 415 V

ACW100H, ACW160H 85 kA

ACW100V, ACW160V 150 kA

ACW101H, ACW161H, ACW250H 85 kA

ACW101V, ACW161V, ACW250V 150 kA

ACW400H, ACW630H 85 kA

ACW400V, ACW630V 150 kA

ACW800U 100 kA

Ics = Icu @ 440 / 460 V

ACW100H, ACW160H 70 kA

ACW100V, ACW160V 130 kA

ACW101H, ACW161H, ACW250H 70 kA

ACW101V, ACW161V, ACW250V 130 kA

ACW400H, ACW630H 70 kA

ACW400V, ACW630V 130 kA

ACW800U 100 kA

ACW100V, 160V, 101V, 161V, 250V, 400V and 630V under request.

Constructive Features

Applicable to Ie (A) Current setting range (A)

ACW250200 160...200

250 200...250

Applicable to Ie (A) Current setting range (A)

ACW400 400 160...400

ACW630 630 252...630

ACW800 800 320...800

Applicable to Ie (A) Current setting range (A)

ACW101

20

Im = 6...12 x In

50

100

ACW161 160

ACW250 220

ACW400 320

ACW630 500

ACW800 630

AVAILABLE RELEASES FMU - Adjustable-thermal

and fixed-magnetic

ATU - Adjustable-thermal

and adjustable-magnetic

ETS - Eletronic LSI

MTU - Magnetic only

Applicable to Ie (A) Current setting range (A)

ACW100

20 16...20

25 20...25

32 25.6...32

40 32...40

50 40...50

63 50.4...63

80 64...80

100 80...100

ACW160125 100...125

160 125...160

Page 137: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

270 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 271

Trip Unit FMU

ADJUSTABLE-THERMAL AND FIXED-MAGNETIC

SETTING RANGES OF TRIP UNITS

Current setting (A) - Ir 0.8; 0.9; 1.0 xIn

Magnetic Trip Unit

Thermal Trip Unit

Current (A) - Im 20~40 50~160

Fixed at 400 A Fixed at 10 xIn

Trip unit identification

Rated operational current - In

Number of poles

Short circuit protection

(magnetic) current value - ImOverload protection (thermal)

current setting - Ir

Trip Unit ATU

Trip unit identification

Rated operational current - In

Number of poles

Short circuit protection (magnetic)

current setting - Im

Overload protection (thermal)

current setting - Ir

ADJUSTABLE-THERMAL AND ADJUSTABLE-MAGNETIC

SETTING RANGES OF TRIP UNITS

Current setting (A) - Ir 0.8; 0.9; 1.0 x In

MAGNETIC TRIP UNIT

THERMAL TRIP UNIT

Current (A) - Im 5; 6; 7; 8; 9; 10 x In

Page 138: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

272 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 273

Trip Unit ETS

Adjustable overload current setting - Ir

Alarm LED

90%Ir ~ 105%Ir = ON

105%Ir or more = Flashing

Adjustable short time current setting - Isd

Trip unit identification

Adjustable time delay setting - tsd

Setting current (A) - Ir 0.4; 0.45; 0.5; 0.55; 0.6; 0.65; 0.7; 0.75; 0.8; 0.85; 0.9; 0.95; 1.0 x In

Tripping time (s) Fixed @ 6x Ir (tolerance ±20%)

Setting current (A) - Isd 1.5; 2; 3; 4; 5; 6; 7; 8; 10 x Ir (tolerance ±15%)

Tripping delay (ms) - tsd 50; 100; 200; 300 (tolerance ±20%)

Current (A) - Ii Fixed at 11x In

OVERLOAD PROTECTION L (LONG TIME)

SHORT-CIRCUIT PROTECTION S (SHORT TIME)

SHORT-CIRCUIT PROTECTION I (INSTANTANEOUS)

SETTING RANGES OF TRIP UNITS

0.5

0.60.7

0.9

1.0

0.8

Trip Unit MTU

Short circuit protection (magnetic) current setting - Im

Trip unit rating - In

Trip unit identification

Current (A) - Im 6; 7.2; 8.4; 9.6; 10.8; 12 x In

MAGNETIC TRIP UNIT

SETTING RANGES OF TRIP UNITS

Page 139: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

274 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 275

Models ACW100 ACW160 ACW101 ACW161 ACW250 ACW400 ACW630 ACW800

Standard IEC 60947-2

Rated current - In (A)

20, 25, 32,

40, 50, 63,

80, 100

125, 160201), 501),

1001) 1601) 200, 250,

2201) 400 630 800

Rated operation voltage - Ue (V)AC 690

DC 500 -

Rated isolation voltage - Ui (V) 750

Rated impulse voltage - Uimp (kV) 8

Frequency (Hz) 50 / 60

Pole number 3

Short-circuit maximum breaking

capacity - Icu (kA)

Type H V H V H V H V H V H V H V U

AC

220/240 V 100 200 100 200 120 200 120 200 120 200 120 200 120 200 120

380/415 V 85 150 85 150 85 150 85 150 85 150 85 150 85 150 100

440/460 V 70 130 40 130 70 130 70 130 70 130 70 130 70 130 100

480/500/525 V 50 65 50 65 65 85 65 8 65 85 65 85 65 85 85

660/690 V 8 10 8 10 15 20 15 20 15 20 20 35 20 35 20

DC250 V 65 100 65 100 85 100 85 100 85 100 - 100 - 100 85

500 V2) 65 100 65 100 85 100 85 100 85 100 - 100 - 100 85

Service short-circuit breaking

capacity - Ics (kA)% Icu 100% 100% 100% 100%

Short circuit making

capacity - Icm (kA)AC

220/240 V 220 440 220 440 264 440 264 440 264 440 264 440 264 440 264

380/415 V 187 330 187 330 187 330 187 330 187 330 187 330 187 330 220

440/460 V 154 286 165 186 154 186 154 286 154 286 154 286 154 286 220

480/500 V 105 134 105 143 143 187 143 187 143 187 143 187 143 187 187

660/690 V 14 17 14 17 30 40 30 40 30 40 40 74 40 74 40

Utilization category A A A A

Isolation characteristic • • • •

Trigger type

Adjustable thermal /

fixed magnetic• - - -

Adjustable thermal

and magnetic- - • - -

LSI electronic - - • •

Adjustable magnetic - • • • (220 A) • (320 A, 500 A) • (630 A)

Mechanical life Number of operations 25,000 25,000 20,000 10,000

Electrical life Number of operations 10,000 10,000 6,000 3,000

Ambient temperature -5...40 °C, with maximum 24h average of 35 °C

Altitude (m) ≤2,000 m above sea level

Connection terminals (mm) Width 23 28 30 50

Type / screw size Philips M8 Allen M8 Allen M10 Allen M12

Tightening torque (Nm) 8 15 50 70

Conductors sectionCables3) (1x) 2.5...95 mm² (1x) 10...150 mm² (2x) 85...240 mm² (3x) 85...240 mm²

Bar 20x5 mm 25x5 mm 30x10 mm 50x10 mm

Weight (kg) 1.5 2.0 5.4 15.1

Dimensions - WxHxD (mm) 90x140x86 105x160x86 140x260x110 210x320x135

Technical Data

Notes: 1) Available only with adjustable magnetic trigger.

2) 2 poles in series.

3) Using PC2 ACW round cable terminal.

Moulded Case Circuit Breaker - ACW

CIRCUIT BREAKERS FOR ELECTRICAL CIRCUIT PROTECTION

TYPE ln (A)

IEC60947-2 - Icu

= Ics

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440-460 V

ACW100H-FMU20-3 20 100 85 70 11111144 4023,00

ACW100H-FMU25-3 25 100 85 70 11111170 4023,00

ACW100H-FMU32-3 32 100 85 70 11111172 4023,00

ACW100H-FMU40-3 40 100 85 70 11111173 4023,00

ACW100H-FMU50-3 50 100 85 70 11111174 4023,00

ACW100H-FMU63-3 63 100 85 70 11111175 4023,00

ACW100H-FMU80-3 80 100 85 70 11111176 4023,00

ACW100H-FMU100-3 100 100 85 70 11111177 4023,00

ACW160H-FMU125-3 125 100 85 70 11111219 6359,00

ACW160H-FMU160-3 160 100 85 70 11111221 6359,00

ACW250H-ATU200-3 200 120 85 70 11111344 10465,00

ACW250H-ATU250-3 250 120 85 70 11111342 11271,00

ACW400H-ETS400-3 400 120 85 70 11111394 19215,00

ACW630H-ETS630-3 630 120 85 70 11111408 23003,00

ACW800U-ETS800-3 800 120 100 100 10583696 36018,00

TYPE ln (A)

IEC60947-2 - Icu

= Ics

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440-460 V

ACW100V-FMU20-3 20 200 150 130 10583682 5500,00

ACW100V-FMU25-3 25 200 150 130 10583683 5500,00

ACW100V-FMU32-3 32 200 150 130 10583684 5500,00

ACW100V-FMU40-3 40 200 150 130 10583691 5500,00

ACW100V-FMU50-3 50 200 150 130 10583685 5500,00

ACW100V-FMU63-3 63 200 150 130 10583686 5500,00

ACW100V-FMU80-3 80 200 150 130 10583687 5500,00

ACW100V-FMU100-3 100 200 150 130 10583688 5500,00

ACW160V-FMU125-3 125 200 150 130 10583689 8694,00

ACW160V-FMU160-3 160 200 150 130 10583690 8694,00

ACW250V-ATU200-3 200 200 150 130 10583692 14306,00

ACW250V-ATU250-3 250 200 150 130 10583693 15409,00

ACW400V-ETS400-3 400 200 150 130 10583694 26269,00

ACW630V-ETS630-3 630 200 150 130 10583695 31446,00

HIGH BREAKING CAPACITY ACW - 20 TO 800 A - 3-POLE

VERY HIGH BREAKING CAPACITY ACW - 20 TO 630 A - 3-POLE 1)

Note : 1) Availability upon request.

160 A 250 A 630 A 800 A

Page 140: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

276 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 277

Moulded Case Circuit Breaker - ACW

CIRCUIT BREAKERS FOR MOTOR BRANCH CIRCUIT PROTECTION

CIRCUIT BREAKERS FOR ELECTRICAL CIRCUIT PROTECTION - 4-POLE

TYPE ln (A)

IEC60947-2 - Icu

= Ics

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440-460 V

ACW101H-MTU20-3 20 120 85 70 11111283 6187,00

ACW101H-MTU50-3 50 120 85 70 11111306 6187,00

ACW101H-MTU100-3 100 120 85 70 11111301 6187,00

ACW161H-MTU160-3 160 120 85 70 11111266 9538,00

ACW250H-MTU220-3 220 120 85 70 11111388 11271,00

ACW400H-MTU320-3 320 120 85 70 11111396 17599,00

ACW630H-MTU500-3 500 120 85 70 11111406 23773,00

ACW800U-MTU630-3 630 120 100 100 10940149 35689,00

TYPE ln (A)

IEC60947-2 - Icu

= Ics

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440-460 V

ACW100H-FMU20-4 20 100 85 70 Upon request Upon request

ACW100H-FMU25-4 25 100 85 70 Upon request Upon request

ACW100H-FMU32-4 32 100 85 70 Upon request Upon request

ACW100H-FMU40-4 40 100 85 70 Upon request Upon request

ACW100H-FMU50-4 50 100 85 70 Upon request Upon request

ACW100HFMU63-4 63 100 85 70 Upon request Upon request

ACW100H-FMU80-4 80 100 85 70 Upon request Upon request

ACW100H-FMU100-4 100 100 85 70 Upon request Upon request

ACW160H-FMU125-4 125 100 85 70 Upon request Upon request

ACW160H-FMU160-4 160 100 85 70 Upon request Upon request

ACW250H-ATU200-4 200 100 85 70 Upon request Upon request

ACW250H-ATU250-4 250 100 85 70 Upon request Upon request

ACW400H-ATU400-4 400 100 85 70 Upon request Upon request

ACW630H-ATU630-4 630 100 85 70 Upon request Upon request

ACW800H-ATU800-4 800 120 100 100 Upon request Upon request

TYPE ln (A)

IEC60947-2 - Icu

= Ics

(kA)

STOCK CODEPRICE EACH

(ZAR)220-240 V 380-415 V 440-460 V

ACW101V-MTU20-3 20 200 150 130 10583697 6903,00

ACW101V-MTU50-3 50 200 150 130 10583699 6903,00

ACW101V-MTU100-3 100 200 150 130 10583701 6903,00

ACW161V-MTU160-3 160 200 150 130 10583702 13040,00

ACW250V-MTU220-3 220 200 150 130 10583703 15409,00

ACW400V-MTU320-3 320 200 150 130 10940133 34813,00

ACW630V-MTU500-3 500 200 150 130 10940135 35689,00

HIGH BREAKING CAPACITY ACW - 20 TO 500 A - 3-POLE

HIGH BREAKING CAPACITY ACW - 20 TO 800 A - 4-POLE

VERY HIGH BREAKING CAPACITY ACW 20 TO 220 A - 3-POLE 1)

Note : 1) Availability upon request.

Internal Accessories

SHUNT RELEASE

Shunt release coil allows shutting off the circuit breaker through an external electric command.

Circuit breaker Voltage Reference

ACW100...800 110~130 V ac / V dc BD ACW100-800 E10

ACW100...800 200~240 V ac / 250 V dc BD ACW100-800 E44

ACW100...800 24 V ac / V dc BD ACW100-800 E26

Supply voltageConsumption

Max. opening time (ms)AC (VA) DC (W) mA

110~130 V ac / V dc 1.36 1.37 10.5

50220~240 V ac / V dc 1.80 1.88 7.5

24 V ac / V dc 0.58 0.58 24

ALARM AUXILIARY CONTACTS

Indicates circuit breakers trip due to overload or short-circuit

condition through a changeover contact (1 NOC).

Circuit breaker model Reference

ACW100...800 AL-1 ACW100-800

ACW ON / OFF TRIP

Alarm

contactALc1

Ala1

ALb1

ALc1

Ala1

ALb1

AUXILIARY CONTACT

Indicates the main contacts status.

Circuit breaker model Reference

ACW100...800 BC-1 ACW100-800

ACW ON OFF / TRIP

Auxiliary

contactAXc1

AXa1

AXb1AXc1

AXa1

AXb1

Page 141: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

278 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 279

AL ALBC BC BC

BD/BS

AL

BC BC BC

BD/BSAL

BCBC

BD/BS

AL

BD/BS

BC BC

UNDERVOLTAGE RELEASE

The undervoltage release opens the circuit breaker when the applied voltage gets between 0.35~0.7 x Ue (rated voltage).

After the device has entered in TRIP state, the circuit breaker can only be closed again when the voltage becomes higher

than 0.85 x Ue.

Circuit breaker Voltage Reference

ACW100...800 110~130 V ac / V dc BS ACW100-800 E10

ACW100...800 200~240 V ac / 250 V dc BS ACW100-800 E44

ACW100...800 380~400 V ac BS ACW100-800 D71

ACW100...800 440~480 V ac BS ACW100-800 D74

Supply voltageConsumption

Max. opening time (ms)AC (VA) DC (W) mA

110~130 V ac / V dc 0.73 0.75 5.8

50220~240 V ac / V dc 1.21 1.35 5.4

380~440 V ac 1.67 - 3.8

440~480 V ac 1.68 - 3.5

ACW100

ACW160

ACW101

ACW161

ACW250

ACW101

ACW630

ACW800

MAXIMUM POSSIBLE CONFIGURATION

External Accessories

MOTORIZED OPERATION Remote operation device Automatic and manual selection through front switch In automatic operation, the switching on and off control is done by electrical signals using pushbuttons In manual operation, the AM motor operator can be only used locally using the switching lever

Circuit breaker Reference Supply voltageResponse time (ms)

Consumption (W) Operations per hourOpening Closing

ACW100 AM ACW100-160 C03 24 V dc 310 200 14 120

ACW160 AM ACW100-160 E36 100~240 V ac / 110~220 V dc 310 200 14 120

ACW101

ACW161

ACW250

ACW400

ACW630

ACW800

AM ACW250 C03 24 V dc 350 230 14 120

AM ACW250 E29 110 V ac / V dc 350 230 14 120

AM ACW250 E46 230 V ac / 220 V dc 350 230 14 120

AM ACW400-630 C03 24 V dc 500 350 35 60

AM ACW400-630 E29 110 V ac / V dc 500 350 35 60

AM ACW400-630 E46 230 V ac / 220 V dc 500 350 35 60

AM ACW800 C03 24 V dc 700 420 35 20

AM ACW800 E29 110 V ac / V dc 700 420 35 20

AM ACW800 E46 230 V ac / 220 V dc 700 420 35 20

1. 2Nm1.2

NmP1 P2

E E

S1 S2

ON OFF

S4

PowerUe

P1

PowerUe

P2

E

ON OFF

E

S1 S2 S4

DIRECT ROTARY OPERATING HANDLE Direct mounting on front part of the circuit breaker Circuit breaker padlocking in OFF position using

1 to 3 padlocks Degree of protection IP40

Circuit breaker Reference

ACW100/160 MRI ACW100-160

ACW101/161/250 MRI ACW250

ACW400/630 MRI ACW400-630

ACW800 MRI ACW800

STANDARD CONNECTION

Manual and remote On/Off

Page 142: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

280 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 281

Accessories for Moulded Case Circuit Breaker - ACW

PLUG-IN KIT

TYPE CIRCUIT-BREAKER STOCK CODEPRICE EACH

(ZAR)

PI ACW100-160 ACW100-160 11111776 4379,00

PI ACW250 ACW250 11111777 5141,00

PI ACW400-630 ACW400-630 11111841 9425,00

PI ACW800 ACW800 11111843 25322,00

SHUNT RELEASE

TYPE CIRCUIT-BREAKER VOLTAGE STOCK CODEPRICE EACH

(ZAR)

BD E10 ACW100-800 ACW100-800 110-130 V ac 10583679 909,00

BD E44 ACW100-800 ACW100-800 200-240 V ac 10583680 909,00

BD ACW100-800 E26 ACW100-800 24 V ac/ca / V dc 10692976 909,00

UNDERVOLTAGE RELEASE

TYPE CIRCUIT-BREAKER VOLTAGE STOCK CODEPRICE EACH

(ZAR)

BS ACW100-800 E10 ACW100-800 110-130 V ac 10583681 1282,00

BS ACW100-800 E44 ACW100-800 200-240 V ac 10583660 1282,00

BS ACW100-800 D71 ACW100-800 380-440 V ac 10583654 1282,00

BS ACW100-800 D74 ACW100-800 440-480 V ac 10583655 1282,00

AUXILIARY CONTACT

TYPE CONTACT CIRCUIT-BREAKER STOCK CODEPRICE EACH

(ZAR)

BC-1 ACW100-800 1 REV ACW100-800 10583677 400,00

ALARM CONTACT

TYPE CONTACT CIRCUIT-BREAKER STOCK CODEPRICE EACH

(ZAR)

AL-1 ACW100-800 1 REV ACW100-800 10583678 400,00

Accessories for Moulded Case Circuit Breaker - ACW

MOTOR OPERATOR

EXTENSION BARS OR TERMINAL TAGS

TYPE CIRCUIT-BREAKER VOLTAGE STOCK CODEPRICE EACH

(ZAR)

AM ACW100-160 E36 ACW100-160 100-240 V ac 10583656 6392,00

AM ACW100-160 C03 ACW100-160 24 V dc 10692992 6392,00

AM ACW250 E29 ACW101-161-250 110 V ac 10583657 6847,00

AM ACW250 E46 ACW101-161-250 230 V ac 10583658 6847,00

AM ACW250 C03 ACW101-161-250 24 V dc 10692993 6847,00

AM ACW400-630 E29 ACW400-630 110 V ac 10583659 12203,00

AM ACW400-630 E46 ACW400-630 230 V ac 10583661 12203,00

AM ACW400-630 C03 ACW400-630 24 V dc 10692994 10611,00

AM ACW800 E29 ACW800 110 V ac 10583662 13350,00

AM ACW800 E46 ACW800 230 V ac 10583663 13350,00

AM ACW800 C03 ACW800 24 V dc 10692995 13350,00

TYPE CIRCUIT-BREAKER VOLTAGE STOCK CODEPRICE EACH

(ZAR)

BE-ACW100-160 ACW100-160 3 10583665 165,00

BE-ACW250 ACW101-161-250 3 10583666 188,00

BE-ACW400-630 ACW400-630 3 10583667 717,00

BE-ACW800 ACW800 3 10583664 1203,00

Page 143: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

282 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 283

Accessories for Moulded Case Circuit Breaker - ACW

ROUND CABLE TERMINAL

TERMINAL COVER

DOOR COUPLING ROTARY HANDLE

INTERNAL ROTARY HANDLE

TYPE CIRCUIT-BREAKER PACKAGING (UN) STOCK CODEPRICE EACH

(ZAR)

PC2 ACW100-160 ACW100-160 3 10583668 554,00

PC2 ACW250 ACW101-161-250 3 10583669 666,00

PC2 ACW400-630 ACW400-630 3 10583671 1687,00

PC2 ACW800 ACW800 3 10583672 3141,00

TYPE CIRCUIT-BREAKER PACKAGING (UN) STOCK CODEPRICE EACH

(ZAR)

CP ACW100-160 ACW100-160 2 10583673 105,00

CP ACW250 ACW101-161-250 2 10583674 105,00

CP ACW400-630 ACW400-630 2 10583675 195,00

CP ACW800 ACW800 2 10583676 307,00

TYPE CIRCUIT-BREAKER SHAFT (mm) STOCK CODEPRICE EACH

(ZAR)

MR469 ACW100-160 ACW100-160 469 10583905 1049,00

MR469 ACW250 ACW101-161-250 469 10583906 1159,00

MR469 ACW400-630 ACW400-630 469 10583646 1964,00

MR469 ACW800 ACW800 469 10583647 2309,00

TYPE CIRCUIT-BREAKER STOCK CODEPRICE EACH

(ZAR)

MRI ACW100-160 ACW100-160 10583652 658,00

MRI ACW250 ACW101-161-250 10583653 729,00

MRI ACW400-630 ACW400-630 10583903 1400,00

MRI ACW800 ACW800 10583904 1652,00

Accessories for Moulded Case Circuit Breaker - ACW

REAR CONNECTION

EARTH LEAKAGE PROTECTION MODULE

MECHANICAL INTERLOCK

TYPE CIRCUIT-BREAKER TERMINAL STOCK CODEPRICE EACH

(ZAR)

TTF ACW100-160 ACW100-160 Flat 11591643 4740,00

TTR ACW100-160 ACW100-160 Rounded 11591644 6573,00

TTF ACW250 ACW101-161-250 Flat 11591645 4859,00

TTR ACW250 ACW101-161-250 Rounded 11591646 11744,00

TTF ACW400-630 ACW400-630 Flat 11591647 27229,00

TTF ACW800 ACW800 Flat 11591658 27229,00

TYPE CIRCUIT-BREAKER TERMINAL STOCK CODEPRICE EACH

(ZAR)

FT ACW250 D88 ACW100-160 220-460 V 11424575 7139,00

FT ACW250 D89 ACW100-160 460-690 V 11591542 11178,00

FT ACW400 D88 ACW400 220-460 V 11424577 11178,00

FT ACW400 D89 ACW400 460-690 V 11591544 11178,00

FT ACW630 D88 ACW630 220-460 V 11424598 11178,00

FT ACW630 D89 ACW630 460-690 V 11591546 14248,00

FT ACW800 D88 ACW800 220-460 V 11424567 14248,00

FT ACW800 D89 ACW800 460-690 V 11591547 14248,00

TYPE CIRCUIT-BREAKER STOCK CODEPRICE EACH

(ZAR)

MI ACW100-160 ACW100-160 11799916 1774,00

MI ACW250 ACW101-161-250 11799917 1983,00

MI ACW400-630 ACW400-630 11800018 2191,00

MI ACW800 ACW800 11800019 2191,00

Page 144: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

284 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 285

ABW Air Circuit Breaker

Designed for the protection of high power electrical circuits, the

ABW Air Circuit Breakers are state-of-the art products in terms of

technology and design.

The characteristics that make this line stand out include:

WIDE RANGE OF CURRENT

adjustment

HIGH SHORT CIRCUIT BREAKING CAPACITY,

WITH ICS = ICU FOR THE ENTIRE SERIES

AVAILABLE IN TWO VERSIONS:

FIXED AND WITHDRAWABLE

COMPLETE RANGE OF ACCESSORIES

MICROPROCESSED ELECTRONIC PROTECTION

UNITS, WITH LSIG PROTECTION AND THE

POSSIBILITY FOR NETWORK COMMUNICATION

ABW 1600 A

ABW 3200 A

ABW 5000 A

ABW 6300 A

ABW16 640 to 1600 A

ABW20 800 to 2000 A

ABW25 1000 to 2500 A

ABW32 1280 to 3200 A

ABW40 1600 to 4000 A

ABW50 2000 to 5000 A

ABW63 2520 to 6300 A

Icu = Ics @ 460/480/500 V

ABW16 65 kA

ABW20 85 kA

ABW25...32 85 kA

ABW40...50 100 kA

ABW63 120 kA

Withdrawable rack

(withdrawable version only)

Arc extinction chambers

Suspension slots

Protection unit

Spring loading lever

OFF Button

TRIP indication

button

ON Button

Status indicator

ON / OFF

Spring charge indicator –

Charged / Not charged

Position locked by padlock

(withdrawable version only)

Position indicator – Inserted / Test /

Withdrawn (withdrawable version only)

Technical data

Operation

counter

Withdrawing rail

(withdrawable version only)

Construction Characteristics

Page 145: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

286 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 287

Technical Data

Notes:

1) For installation above 2000 m from sea level, please consider derating factors, as shown in the chart below;

2) For ambient temperature above 40 °C, check maximum rated current values in the chart below;

3) Including withdrawable rack.

  ABW16 ABW20 ABW25 ABW32 ABW40 ABW50 ABW63

Max. Rated Current - In max. (A) (40 °C) 1600 2000 2500 3200 4000 5000 6300

Rated Operational Voltage - Ue (V) 690

Rated Insulation Voltage - Ui (V) 1000

Impulse Voltage - Uimp (kV) 12

Frequency (Hz) 50 / 60

Number of poles 3 / 4

Versions Fixed / Withdrawable

Protection units Electronic

Rated ultimate short-circuit breaking capacity - Icu (kA)

220 / 380 / 415 V 65 85 100 120

440 / 480 / 500 V 65 85 100 120

550 / 600 / 690 V 50 85 85 100

Rated service short-circuit breaking capacity - Ics (kA)

220 / 380 / 415 V 65 85 100 120

440 / 480 / 500 V 65 85 100 120

550 / 600 / 690 V 50 85 85 100

Rated short-time withstand current - Icw (kA)

1 s 50 85 85 100

2 s 42 75 75 90

3 s 36 65 65 85

Rated making capacity - Icm (kA peak)

220 / 380 / 415 V 143 187 220 264

440 / 480 / 500 V 143 187 220 264

550 / 600 / 690 V 105 187 187 220

Utilisation category B

Operating time (ms)Max. total breaking time 40

Max. closing time 80

Mechanical lifespan (number of operations)Without maintenance 20000 15000 10000 10000

With maintenance 30000 20000 15000 15000

Electrical lifespan (number of operations)Without maintenance 5000 5000 2000 2000

With maintenance 10000 10000 5000 5000

Altitude (m) ≤ 20001)

Ambient temperatureOperating -5...40 °C2)

Storage -20...60 °C

Weight (kg)Withdrawable3) 61 85 143 184

Fixed 32 42 74 96

Connection terminal - Fixed / WithdrawableHorizontal Standard

Vertical Standard - change position Optional (under request)

External dimensions HxWxD (mm)

3PWithdrawable 430x334x424 430x412x424 460x629x449 460x785x449

Fixed 320x354x328 320x432x328 380x649x363 380x805x363

4PWithdrawable 430x419x424 430x527x424 460x799x449 460x1015x449

Fixed 320x439x328 320x547x328 380x819x363 380x1035x363

Altitude - h Rated voltage reduction factor Insulation voltage Rated current reduction factor

h ≤ 2000 m 690 1000 1.00

2000 < h ≤ 3000 m 590 900 0.99

3000 < h ≤ 4000 m 520 700 0.96

4000 < h ≤ 5000 m 460 600 0.94

Horizontal position terminal Vertical position terminal

Ambienttemperature

ABW16 ABW20 ABW25 ABW32 ABW40 ABW50 ABW63 ABW16 ABW20 ABW25 ABW32 ABW40 ABW50 ABW63

40 °C 1600 2000 2500 3200 4000 5000 6300 1600 2000 2500 3200 4000 5000 6300

45 °C 1600 2000 2500 3200 3900 5000 6300 1600 2000 2500 3200 3950 5000 6300

50 °C 1600 2000 2500 3100 3800 4900 6200 1600 2000 2500 3150 3850 4950 6250

55 °C 1550 2000 2400 3000 3700 4800 6100 1600 2000 2450 3050 3750 4850 6150

60 °C 1500 2000 2300 2900 3600 4700 6000 1550 2000 2350 2950 3650 4750 6050

Air Circuit Breaker - ABW

3-POLE CIRCUIT BREAKERS

FIXED 3-POLE + OPENING AND CLOSING COILS 200...250 V AC/DC 1)

WITHDRAWABLE 3-POLE + OPENING AND CLOSING COILS 200...250 V AC/DC 1) 2)

TYPElN (A)

OVERLOAD RANGEPROTECTION TYPE FRAME SIZE I

cs (kA) 480 V

STOCK CODE

50 Hz

PRICE EACH

(ZAR)

ABW16DN3-16AZ F-A0220 640 - 1600 LSIG 08-16 65 11403391 49917,00

ABW20ES3-20AZ F-A0220 800 - 2000 LSIG 20-32 85 11447021 60613,00

ABW25ES3-25AZ F-A0220 1000 - 2500 LSIG 20-32 85 11447024 74875,00

ABW32ES3-32AZ F-A0220 1280 - 3200 LSIG 20-32 85 11399003 96267,00

ABW40FS3-40AZ F-A0220 1600 - 4000 LSIG 40-50 100 11384055 142618,00

ABW50FS3-50AZ F-A0220 2000 - 5000 LSIG 40-50 100 11447034 192534,00

ABW63GS3-63AZ F-A0220 2520 - 6300 LSIG 63 120 11447036 267409,00

TYPEln (A)

OVERLOAD RANGEPROTECTION TYPE FRAME SIZE I

cs (kA) 480 V

STOCK CODE

50 Hz

PRICE EACH

(ZAR)

ABW16DN3-16AZ E-A0220 640 - 1600 LSIG 08-16 65 11447018 80223,00

ABW20ES3-20AZ E-A0220 800 - 2000 LSIG 20-32 85 11447023 92702,00

ABW25ES3-25AZ E-A0220 1000 - 2500 LSIG 20-32 85 11447025 110529,00

ABW32ES3-32AZ E-A0220 1280 - 3200 LSIG 20-32 85 11447027 139053,00

ABW40FS3-40AZ E-A0220 1600 - 4000 LSIG 40-50 100 11447028 235320,00

ABW50FS3-50AZ E-A0220 2000 - 5000 LSIG 40-50 100 11447035 288801,00

ABW63GS3-63AZ E-A0220 2520 - 6300 LSIG 63 120 11447037 445681,00

MOTOR OPERATION COIL

CODE CODE

0 - W/o Mot. Op. 0 - Without coil

1 - 100...130 V ac/ca / V dc/cc 1 - 100...130 V ac/ca / V dc/cc

2 - 200...250 V ac/ca / V dc/cc 2 - 200...250 V ac/ca / V dc/cc

3 - 24...30 V dc/cc 3 - 24...30 V dc/cc

4 - 48...60 V ac/ca / V dc/cc

5 - 480 V ac/ca

Note: 1) Standard accessories

Protection unit ABW-AZ_.

Input voltage 100...250 V ac/dc.

Current measurement per phase.

Chronologic register of 10 faults.

Auxiliary contacts (5NO + 5NC).

Alarm contacts (3NO).

Operations counter.

2) Standard accessories (withdrawable):

Keylock position lock.

Position indicator (Connected / Test / Disconnected).

3) Upon request.

- Fill in with the motorized operation voltage code (automatic spring charge).

- Fill in with the closing and opening coil voltage code.

- Fill in with the power input frequency - 6 = 50 Hz; 1 = 60 Hz.

Page 146: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

288 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 289

Air Circuit Breaker - ABW

3-POLE CIRCUIT BREAKERS

FIXED 3-POLE + OPENING AND CLOSING COILS + MOTORIZED OPERATION 1)

WITHDRAWABLE 3-POLE + OPENING AND CLOSING COILS + MOTORIZED OPERATION 1) 2)

TYPEln (A)

OVERLOAD RANGEPROTECTION TYPE FRAME SIZE I

cs (kA) 480 V

STOCK CODE

50 Hz

PRICE EACH

(ZAR)

ABW08DN3-08AZ F-A 0 320 - 800 LSIG 08-16 65 Upon request 3) Upon request

ABW16DN3-16AZ F-A 0 640 - 1600 LSIG 08-16 65 Upon request 3) Upon request

ABW20ES3-20AZ F-A 0 800 - 2000 LSIG 20-32 85 Upon request 3) Upon request

ABW25ES3-25AZ F-A 0 1000 - 2500 LSIG 20-32 85 Upon request 3) Upon request

ABW32ES3-32AZ F-A 0 1280 - 3200 LSIG 20-32 85 Upon request 3) Upon request

ABW40FS3-40AZ F-A 0 1600 - 4000 LSIG 40-50 100 Upon request 3) Upon request

ABW50FS3-50AZ F-A 0 2000 - 5000 LSIG 40-50 100 Upon request 3) Upon request

ABW63GS3-63AZ F-A 0 2520 - 6300 LSIG 63 120 Upon request 3) Upon request

MOTOR OPERATION COIL

CODE CODE

0 - W/o Mot. Op. 0 - Without coil

1 - 100...130 V ac/ca / V dc/cc 1 - 100...130 V ac/ca / V dc/cc

2 - 200...250 V ac/ca / V dc/cc 2 - 200...250 V ac/ca / V dc/cc

3 - 24...30 V dc/cc 3 - 24...30 V dc/cc

4 - 48...60 V ac/ca / V dc/cc

5 - 480 V ac/ca

TYPEln (A)

OVERLOAD RANGEPROTECTION TYPE FRAME SIZE I

cs (kA) 480 V

STOCK CODE

50 Hz

PRICE EACH

(ZAR)

ABW08DN3-08AZ E-A 0 320 - 800 LSIG 08-16 65 Upon request 3) Upon request

ABW16DN3-16AZ E-A 0 640 - 1600 LSIG 08-16 65 Upon request 3) Upon request

ABW20ES3-20AZ E-A 0 800 - 2000 LSIG 20-32 85 Upon request 3) Upon request

ABW25ES3-25AZ E-A 0 1000 - 2500 LSIG 20-32 85 Upon request 3) Upon request

ABW32ES3-32AZ E-A 0 1280 - 3200 LSIG 20-32 85 Upon request 3) Upon request

ABW40FS3-40AZ E-A 0 1600 - 4000 LSIG 40-50 100 Upon request 3) Upon request

ABW50FS3-50AZ E-A 0 2000 - 5000 LSIG 40-50 100 Upon request 3) Upon request

ABW63GS3-63AZ E-A 0 2520 - 6300 LSIG 63 120 Upon request 3) Upon request

Note : 1) Standard accessories

Protection unit ABW-AZ_.

Input voltage 100...250 V ac/dc.

Current measurement per phase.

Chronologic register of 10 faults.

Auxiliary contacts (5NO + 5NC).

Alarm contacts (3NO).

Operations counter.

2) Standard accessories (withdrawable) :

Keylock position lock.

Position indicator (Connected / Test / Disconnected).

3) Upon request.

- Fill in with the motorized operation voltage code (automatic spring charge).

- Fill in with the closing and opening coil voltage code.

- Fill in with the power input frequency - 6 = 50 Hz; 1 = 60 Hz.

Air Circuit Breaker - ABW

4-POLE CIRCUIT BREAKERS

FIXED 4-POLE + OPENING AND CLOSING COILS 200...250 V AC/DC 1)

TYPEln (A)

OVERLOAD RANGEPROTECTION TYPE FRAME SIZE I

cs (kA) 480 V

STOCK CODE

50 Hz

PRICE EACH

(ZAR)

ABW16DN4-16AZ F-A0220 640 - 1600 LSIG 08-16 65 11432101 91973,00

ABW20ES4-20AZ F-A0220 800 - 2000 LSIG 20-32 85 11432102 108287,00

ABW25ES4-25AZ F-A0220 1000 - 2500 LSIG 20-32 85 11432103 139664,00

ABW32ES4-32AZ F-A0220 1280 - 3200 LSIG 20-32 85 11432105 180715,00

ABW40FS4-40AZ F-A0220 1600 - 4000 LSIG 40-50 100 11432106 273283,00

ABW50FS4-50AZ F-A0220 2000 - 5000 LSIG 40-50 100 11432107 339031,00

ABW63GS4-63AZ F-A0220 2520 - 6300 LSIG 63 120 11432128 471775,00

WITHDRAWABLE 4-POLE + OPENING AND CLOSING COILS 200...250 V AC/DC 1) 2)

TYPEln (A)

OVERLOAD RANGEPROTECTION TYPE FRAME SIZE I

cs (kA) 480 V

STOCK CODE

50 Hz

PRICE EACH

(ZAR)

ABW16DN4-16AZ E-A0220 640 - 1600 LSIG 08-16 65 11432129 135185,00

ABW20ES4-20AZ E-A0220 800 - 2000 LSIG 20-32 85 11432130 151181,00

ABW25ES4-25AZ E-A0220 1000 - 2500 LSIG 20-32 85 11432131 182519,00

ABW32ES4-32AZ E-A0220 1280 - 3200 LSIG 20-32 85 11432132 222698,00

ABW40FS4-40AZ E-A0220 1600 - 4000 LSIG 40-50 100 11432133 386405,00

ABW50FS4-50AZ E-A0220 2000 - 5000 LSIG 40-50 100 11432134 471262,00

ABW63GS4-63AZ E-A0220 2520 - 6300 LSIG 63 120 11432135 721968,00

MOTOR OPERATION COIL

CODE CODE

0 - W/o Mot. Op. 0 - Without coil

1 - 100...130 V ac/ca / V dc/cc 1 - 100...130 V ac/ca / V dc/cc

2 - 200...250 V ac/ca / V dc/cc 2 - 200...250 V ac/ca / V dc/cc

3 - 24...30 V dc/cc 3 - 24...30 V dc/cc

4 - 48...60 V ac/ca / V dc/cc

5 - 480 V ac/ca

Note: 1) Standard accessories :

Protection unit ABW-AZ_.

Input voltage 100...250 V ac/dc.

Current measurement per phase.

Chronologic register of 10 faults.

Auxiliary contacts (5NO + 5NC).

Alarm contacts (3NO).

Operations counter.

2) Standard accessories (withdrawable) :

Keylock position lock.

Position indicator (Connected / Test / Disconnected).

3) Upon request.

- Fill in with the motorized operation voltage code (automatic spring charge).

- Fill in with the closing and opening coil voltage code.

- Fill in with the power input frequency - 6 = 50 Hz; 1 = 60 Hz.

Page 147: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

290 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 291

Air Circuit Breaker - ABW

4-POLE CIRCUIT BREAKERS

FIXED 4-POLE + OPENING AND CLOSING COILS + MOTORIZED OPERATION 1)

WITHDRAWABLE 4-POLE + OPENING AND CLOSING COILS + MOTORIZED OPERATION 1) 2)

TYPEln (A)

OVERLOAD RANGEPROTECTION TYPE FRAME SIZE I

cs (kA) 480 V

STOCK CODE

50 Hz

PRICE EACH

(ZAR)

ABW08DN4-08AZ F-A 0 320 - 800 LSIG 08-16 65 Upon request 3) Upon request

ABW16DN4-16AZ F-A 0 640 - 1600 LSIG 08-16 65 Upon request 3) Upon request

ABW20ES4-20AZ F-A 0 800 - 2000 LSIG 20-32 85 Upon request 3) Upon request

ABW25ES4-25AZ F-A 0 1000 - 2500 LSIG 20-32 85 Upon request 3) Upon request

ABW32ES4-32AZ F-A 0 1280 - 3200 LSIG 20-32 85 Upon request 3) Upon request

ABW40FS4-40AZ F-A 0 1600 - 4000 LSIG 40-50 100 Upon request 3) Upon request

ABW50FS4-50AZ F-A 0 2000 - 5000 LSIG 40-50 100 Upon request 3) Upon request

ABW63GS4-63AZ F-A 0 2520 - 6300 LSIG 63 120 Upon request 3) Upon request

TYPEln (A)

OVERLOAD RANGEPROTECTION TYPE FRAME SIZE I

cs (kA) 480 V

STOCK CODE

50 Hz

PRICE EACH

(ZAR)

ABW08DN4-08AZ E-A 0 320 - 800 LSIG 08-16 65 Upon request 3) Upon request

ABW16DN4-16AZ E-A 0 640 - 1600 LSIG 08-16 65 Upon request 3) Upon request

ABW20ES4-20AZ E-A 0 800 - 2000 LSIG 20-32 85 Upon request 3) Upon request

ABW25ES4-25AZ E-A 0 1000 - 2500 LSIG 20-32 85 Upon request 3) Upon request

ABW32ES4-32AZ E-A 0 1280 - 3200 LSIG 20-32 85 Upon request 3) Upon request

ABW40FS4-40AZ E-A 0 1600 - 4000 LSIG 40-50 100 Upon request 3) Upon request

ABW50FS4-50AZ E-A 0 2000 - 5000 LSIG 40-50 100 Upon request 3) Upon request

ABW63GS4-63AZ E-A 0 2520 - 6300 LSIG 63 120 Upon request 3) Upon request

MOTOR OPERATION COIL

CODE CODE

0 - W/o Mot. Op. 0 - Without coil

1 - 100...130 V ac/ca / V dc/cc 1 - 100...130 V ac/ca / V dc/cc

2 - 200...250 V ac/ca / V dc/cc 2 - 200...250 V ac/ca / V dc/cc

3 - 24...30 V dc/cc 3 - 24...30 V dc/cc

4 - 48...60 V ac/ca / V dc/cc

5 - 480 V ac/ca

Note: 1) Standard accessories :

Protection unit ABW-AZ_.

Input voltage 100...250 V ac/dc.

Current measurement per phase.

Chronologic register of 10 faults.

Auxiliary contacts (5NO + 5NC).

Alarm contacts (3NO).

Operations counter.

2) Standard accessories (withdrawable) :

Keylock position lock.

Position indicator (Connected / Test / Disconnected).

3) Upon request.

- Fill in with the motorized operation voltage code (automatic spring charge).

- Fill in with the closing and opening coil voltage code.

- Fill in with the power input frequency - 6 = 50 Hz; 1 = 60 Hz.

Accessories for Air Circuit Breaker - ABW

FACTORY-ASSEMBLED ACCESSORIES

PROTECTION AND MEASUREMENT UNITS 1)

TYPE CIRCUIT BREAKER FREQUENCY VOLTAGE CODEPRICE EACH

(ZAR)

ABW-AF1 ABW16-63 60 100-250 V ac/ca / V dc/cc AF1 Upon request

ABW-AF6 ABW16-63 50 100-250 V ac/ca / V dc/cc AF6 Upon request

ABW-AC1 ABW16-63 60 100-250 V ac/ca / V dc/cc AC1 Upon request

ABW-AC6 ABW16-63 50 100-250 V ac/ca / V dc/cc AC6 Upon request

ABW-AC2 ABW16-63 N/A 24-60 V dc/cc AC2 Upon request

ABW-PC1 ABW16-63 60 100-250 V ac/ca / V dc/cc PC1 2) Upon request

ABW-PC6 ABW16-63 50 100-250 V ac/ca / V dc/cc PC6 2) Upon request

ABW-PC2 ABW16-63 N/A 24-60 V dc/cc PC2 2) Upon request

ABW-AZ2 ABW16-63 N/A 24-60 V dc/cc AZ2 2) Upon request

Note : 1) These acc. are assembled in the factory. Include the price in the ACB’s price and request the ACB’s code with the assembled acc.

2) Requires VDW voltage measurement module.

Protection unit Standard AZ_ unit characteristics + Earth leakage protection possibility (no communication). Protection unit Standard AZ_ unit characteristics + MODBUS communication (monitoring and diagnosis) and communication possibility

Profibus (including ABW-CP module). To connect/disconnect the circuit breaker through communication it is necessary to include the ABW-CM or ABW-CP

module (accessory). Protection unit / Standard AC_ characteristics + Maximum and minimum current and voltage protections, current unbalance and out of

range frequency. Current, voltage, power, frequency, power factor and phase angle measurement. 256 fault event log.

Example: To describe the circuit breaker, substitute the standard AZ_ code for the chosen unit code: Standard AZ1 circuit breaker unit : ABW16DN4-16AZ1E-A0220 Chosen AC1 circuit breaker unit : ABW16DN4-16AC1E-A0220

Page 148: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

292 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 293

Accessories for Air Circuit Breaker - ABW

Note : Example: Circuit breaker with instantaneous under voltage coil @ 200...250 V ac/dc: ABW16DN4-16AZ1E-A0222

Note: Example: Withdrawable circuit breaker with position auxiliary contacts: ABW16DN4-16AZ1E-B0220

Note : Example: Changeover using 2 withdrawable ACBs with mechanical interlock: ABW16DN4-16AZ1E-A0220M

Note: Example: Circuit breaker with door interlock: ABW16DN4-16AZ1E-A0220D

FACTORY-ASSEMBLED ACCESSORIES

UNDER VOLTAGE COIL 1)

POSITION AUXILIARY CONTACTS (WITHDRAWABLE CIRCUIT BREAKERS) 1)

MECHANICAL INTERLOCK 1)

DOOR INTERLOCK 1)

TYPE CIRCUIT-BREAKER VOLTAGE CODE STOCK CODEPRICE EACH

(ZAR)

ABW-UVT C34 ABW08-63 24-30 V dc/cc 3 11193882 1863,00

ABW-UVT E27 ABW08-63 48 V ac/ca / V dc/cc 4 11193884 1863,00

ABW-UVT E10 ABW08-63 110-130 V ac/ca / V dc/cc 1 11193888 1863,00

ABW-UVT E12 ABW08-63 200-250 V ac/ca / V dc/cc 2 11193854 1863,00

ABW-UVT E55 ABW08-63 380-480 V ac/ca / V dc/cc 5 11193883 1863,00

TYPE CIRCUIT-BREAKER CODE STOCK CODEPRICE EACH

(ZAR)

ABW-IM1 2D/F ABW08, 16, 40 and 50 M 11194710 17482,00

ABW-IM2 2E/G ABW20, 25, 32, and 63 M 11194711 17482,00

ABW-IM1 3D/F ABW08, 16, 40 and 50 M3 11194713 38839,00

ABW-IM2 3E/G ABW20, 25, 32, and 63 M3 11194717 38839,00

TYPE CIRCUIT-BREAKER CODE STOCK CODEPRICE EACH

(ZAR)

ABW-DI ABW08-63 D 11195050 1733,00

TYPE CIRCUIT-BREAKER CODE STOCK CODEPRICE EACH

(ZAR)

ABW-BC4 ABW08-63 B 11194966 3465,00

Note : 1) These acc. are assembled in the factory. Include the price in the ACB’s price and request the ACB’s code with the assembled acc.

Accessories for Air Circuit Breaker - ABW

FIELD-ASSEMBLED ACCESSORIES

MODBUS COMMUNICATION MODULE

PROFIBUS COMMUNICATION MODULE 2)

UNDERVOLTAGE MODULE WITH TIMER 3S 3)

TYPE CIRCUIT BREAKER PROTOCOL STOCK CODEPRICE EACH

(ZAR)

ABW-CM 1) ABW08-63 Modbus 11193398 35978,00

TYPE CIRCUIT BREAKER PROTOCOL STOCK CODEPRICE EACH

(ZAR)

ABW-CP ABW08-63 Profibus 11193400 59913,00

TYPE CIRCUIT BREAKER PROTOCOL STOCK CODEPRICE EACH

(ZAR)

ABW-UDC E27 ABW08-63 48 VAC / VDC 11193478 3465,00

ABW-UDC E10 ABW08-63 110-130 VAC / VDC 11193451 3465,00

ABW-UDC E12 ABW08-63 200-250 VAC / VDC 11193452 3465,00

ABW-UDC E55 ABW08-63 380-480 VAC / VAC 11193453 3465,00

Note : 1) It is only possible to use the ABW-CM with the ABW circuit-breaker with AC_ or PC_ protection units, which already have MODBUS communication for

monitoring and diagnosis. The ABW-CM module allows the operatio (connection/disconnection) of the circuit-breaker via communication.

2) It is only possible to use with ACBs with AC_ or PC_ protection units.

3) It is only possible to use with ACBs that have ABW-UVT under voltage coil.

Page 149: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

294 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 295

Accessories for Air Circuit Breaker - ABW

FIELD-ASSEMBLED ACCESSORIES

CONDENSER TRIPPING DEVICE

DOOR FRAME

KEY LOCK

TRANSPARENT COVER

TYPE CIRCUIT BREAKER VOLTAGE (V) STOCK CODEPRICE EACH

(ZAR)

ABW-UC D58 ABW08-63 100-110 V ac 11193370 4173,00

ABW UC D64 ABW08-63 200-220 V ac 11193376 4173,00

TYPE CIRCUIT BREAKER VOLTAGE (V) STOCK CODEPRICE EACH

(ZAR)

ABW-DFF ABW08-63 Fixed 11321382 1297,00

ABW-DFE ABW08-63 Withdrawable 11195048 1297,00

TYPE CIRCUIT BREAKER DESCRIPTION STOCK CODEPRICE EACH

(ZAR)

ABW-BK1 ABW08-63 Key lock 11194682 2698,00

ABW-IK2 ABW08-63 Key interlock 11194685 7795,00

ABW-BB ABW08-63 Pushbutton lock 11194681 403,00

TYPE CIRCUIT BREAKER STOCK CODEPRICE EACH

(ZAR)

ABW-DC ABW08-63 11195053 5154,00

Accessories for Air Circuit Breaker - ABW

FIELD-ASSEMBLED ACCESSORIES

EARTH LEAKAGE PROTECTION CT

CONTROL TERMINAL (REMOVABLE)

TYPE CIRCUIT BREAKER INTERNAL DIAMETER (mm) RATED CURRENT STOCK CODEPRICE EACH

(ZAR)

ABW-ZCT-120 ABW08-63 120 1000 A 11195018 6707,00

ABW-ZCT-200 ABW08-63 200 2000 A 11195019 12072,00

TYPE CIRCUIT BREAKER VOLTAGE (50/60 Hz) STOCK CODEPRICE EACH

(ZAR)

ABW-UJ ABW08-63 3 11406758 284,00

PHASE BARRIERS

VOLTAGE MODULE OF PC_ TRIP UNIT

TYPE CIRCUIT BREAKER VOLTAGE (50/60 Hz) STOCK CODEPRICE EACH

(ZAR)

ABW-IB ABW08-63 2 11194726 492,00

TYPE CIRCUIT BREAKER VOLTAGE (50/60 Hz) STOCK CODEPRICE EACH

(ZAR)

ABW-VDM ABW08-63 60-690 V ac/ca 11506529 3846,00

Page 150: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

296 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 297

REFERENCE MDW

Miniature Circuit-Breakers - MDW and MDWH Overview

TRIPPING CHARACTERISTIC CURVES

Curve B

The main characteristic of the miniature circuit-breaker of the

B curve is the instantaneous trip for currents 3 to 5 times

above the rated current. Therefore, they are applied mainly in

the protection of circuits with resistive characteristics or with

great cable lengths involved. E.g.: incandescent light bulbs,

electric showers, electric heaters, etc.

Curve C

The characteristic of the miniature circuit-breaker of the C

curve is the instantaneous trip for currents 5 to 10 times

above the rated current. Therefore, they are used for the

protection of circuits with installation of inductive loads.

E.g.: fluorescent lamps, refrigerators, washing machines, etc.

The MDW and MDWH miniature circuit-breaker (MCB) line offers

protection against overload and short-circuit in electric conductors,

complying with the tripping characteristic curves B and C, according

to standards IEC 60898 and IEC 60947-2. Developed to be used in

low voltage circuits with direct or alternating current from 2 to 125 A

and short-circuit breaking capacity up to 10 kA, the miniature

circuit-breaker line includes as accessories: auxiliary contact blocks,

single, two and three-pole distribution busbar, and padlock,

according to the requirement of safety standards. It also includes

trip free mechanism, in which the trip is independent from the

handle, and circuit-breaker status indication.

Single-Pole Miniature Circuit-Breakers

ors,

rding

d in

5 A

cks,

Min

ute

sS

ec

on

ds

Trip

pin

g t

ime

Reference Current Curve

IEC 60898

230/400 V ac

Icn (kA)

IEC 60947-2

230/400 V ac

Icu (kA)

- - - - -

- - - - -

MDW-B6 6 A B 3 5

MDW-B10 10 A B 3 5

MDW-B16 16 A B 3 5

MDW-B20 20 A B 3 5

MDW-B25 25 A B 3 5

MDW-B32 32 A B 3 5

MDW-B40 40 A B 3 5

MDW-B50 50 A B 3 5

MDW-B63 63 A B 3 5

MDW-B70 70 A B 3 5

MDW-B80 80 A B 3 5

MDW-B100 100 A B 3 5

MDW-B125 125 A B 3 5

Reference Current Curve

IEC 60898

230/400 V ac

Icn (kA)

IEC 60947-2

230/400 V ac

Icu (kA)

MDW-C2 2 A C 1.5 3

MDW-C4 4 A C 1.5 3

MDW-C6 6 A C 3 5

MDW-C10 10 A C 3 5

MDW-C16 16 A C 3 5

MDW-C20 20 A C 3 5

MDW-C25 25 A C 3 5

MDW-C32 32 A C 3 5

MDW-C40 40 A C 3 5

MDW-C50 50 A C 3 5

MDW-C63 63 A C 3 5

MDW-C70 70 A C 3 5

MDW-C80 80 A C 3 5

MDW-C100 100 A C 3 5

MDW-C125 125 A C 3 5

Miniature Circuit-Breakers

1-Pole MCB

CURVE B, Im = 3 TO 5xI

n

CURVE C, Im = 5 TO 10xI

n

TYPE In (A)

IEC898 230/400 V

Icn

(kA)

IEC947-2 230 V

Icu

(kA)PACKAGING STOCK CODE

PRICE EACH

(ZAR)

MDW-B6 6 3 5 12 10076396 48,00

MDW-B10 10 3 5 12 10076404 43,00

MDW-B16 16 3 5 12 10076412 43,00

MDW-B20 20 3 5 12 10076420 43,00

MDW-B25 25 3 5 12 10076428 43,00

MDW-B32 32 3 5 12 10076436 43,00

MDW-B40 40 3 5 12 10076444 43,00

MDW-B50 50 3 5 12 10076452 54,00

MDW-B63 63 3 5 12 10076460 54,00

MDW-B70 70 3 5 6 11134694 164,00

MDW-B80 80 3 5 6 10076468 164,00

MDW-B100 100 3 5 6 10075742 164,00

MDW-B125 125 3 5 6 11807321 164,00

TYPE In (A)

IEC898 230/400 V

Icn

(kA)

IEC947-2 230 V

Icu

(kA)PACKAGING STOCK CODE

PRICE EACH

(ZAR)

MDW-C2 2 1,5 3 12 10076381 58,00

MDW-C4 4 1,5 3 12 10076389 58,00

MDW-C6 6 3 5 12 10076397 49,00

MDW-C10 10 3 5 12 10076405 44,00

MDW-C16 16 3 5 12 10076413 44,00

MDW-C20 20 3 5 12 10076421 44,00

MDW-C25 25 3 5 12 10076429 44,00

MDW-C32 32 3 5 12 10076437 44,00

MDW-C40 40 3 5 12 10076445 44,00

MDW-C50 50 3 5 12 10076453 55,00

MDW-C63 63 3 5 12 10076461 55,00

MDW-C70 70 3 5 6 11134789 167,00

MDW-C80 80 3 5 6 10076469 167,00

MDW-C100 100 3 5 6 10075743 167,00

MDW-C125 125 3 5 6 11807325 167,00

Page 151: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

298 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 299

Miniature Circuit-Breakers

2-POLE MCB

CURVE B, Im = 3 TO 5xI

n

CURVE C, Im = 5 TO 10xI

n

TYPE In (A)

IEC898 230/400 V

Icn

(kA)

IEC947-2 230 V

Icu

(kA)PACKAGING STOCK CODE

PRICE EACH

(ZAR)

MDW-B6-2 6 3 5 6 10076398 101,00

MDW-B10-2 10 3 5 6 10076406 90,00

MDW-B16-2 16 3 5 6 10076414 90,00

MDW-B20-2 20 3 5 6 10076422 90,00

MDW-B25-2 25 3 5 6 10076430 90,00

MDW-B32-2 32 3 5 6 10076438 90,00

MDW-B40-2 40 3 5 6 10076446 90,00

MDW-B50-2 50 3 5 6 10076454 112,00

MDW-B63-2 63 3 5 6 10076462 112,00

MDW-B70-2 70 3 5 3 11134696 330,00

MDW-B80-2 80 3 5 3 10076470 330,00

MDW-B100-2 100 3 5 3 10075744 330,00

MDW-B125-2 125 3 5 3 11807322 330,00

TYPE In (A)

IEC898 230/400 V

Icn

(kA)

IEC947-2 230 V

Icu

(kA)PACKAGING STOCK CODE

PRICE EACH

(ZAR)

MDW-C2-2 2 1,5 3 6 10076383 121,00

MDW-C4-2 4 1,5 3 6 10076391 121,00

MDW-C6-2 6 3 5 6 10076399 104,00

MDW-C10-2 10 3 5 6 10076407 92,00

MDW-C16-2 16 3 5 6 10076415 92,00

MDW-C20-2 20 3 5 6 10076423 92,00

MDW-C25-2 25 3 5 6 10076431 92,00

MDW-C32-2 32 3 5 6 10076439 92,00

MDW-C40-2 40 3 5 6 10076447 92,00

MDW-C50-2 50 3 5 6 10076455 115,00

MDW-C63-2 63 3 5 6 10076463 115,00

MDW-C70-2 70 3 5 3 11134790 339,00

MDW-C80-2 80 3 5 3 10076471 339,00

MDW-C100-2 100 3 5 3 10075745 339,00

MDW-C125-2 125 3 5 3 11807327 339,00

Miniature Circuit-Breakers

3-POLE MCB

CURVE B, Im = 3 TO 5xI

n

TYPE In (A)

IEC898 230/400 V

Icn

(kA)

IEC947-2 230 V

Icu

(kA)PACKAGING STOCK CODE

PRICE EACH

(ZAR)

MDW-B6-3 6 3 5 4 10076400 151,00

MDW-B10-3 10 3 5 4 10076408 134,00

MDW-B16-3 16 3 5 4 10076416 134,00

MDW-B20-3 20 3 5 4 10076424 134,00

MDW-B25-3 25 3 5 4 10076432 134,00

MDW-B32-3 32 3 5 4 10076440 134,00

MDW-B40-3 40 3 5 4 10076448 134,00

MDW-B50-3 50 3 5 4 10076456 168,00

MDW-B63-3 63 3 5 4 10076464 168,00

MDW-B70-3 70 3 5 2 11134697 494,00

MDW-B80-3 80 3 5 2 10077877 494,00

MDW-B100-3 100 3 5 2 10075746 494,00

MDW-B125-3 125 3 5 2 11807323 494,00

CURVE C, Im = 5 TO 10xI

n

TYPE In (A)

IEC898 230/400 V

Icn

(kA)

IEC947-2 230 V

Icu

(kA)PACKAGING STOCK CODE

PRICE EACH

(ZAR)

MDW-C2-3 2 1,5 3 4 10076385 181,00

MDW-C4-3 4 1,5 3 4 10076393 181,00

MDW-C6-3 6 3 5 4 10076401 156,00

MDW-C10-3 10 3 5 4 10076409 138,00

MDW-C16-3 16 3 5 4 10076417 138,00

MDW-C20-3 20 3 5 4 10076425 138,00

MDW-C25-3 25 3 5 4 10076433 138,00

MDW-C32-3 32 3 5 4 10076441 138,00

MDW-C40-3 40 3 5 4 10076449 138,00

MDW-C50-3 50 3 5 4 10076457 173,00

MDW-C63-3 63 3 5 4 10076465 173,00

MDW-C70-3 70 3 5 2 11134791 509,00

MDW-C80-3 80 3 5 2 10075739 509,00

MDW-C100-3 100 3 5 2 10075747 509,00

MDW-C125-3 125 3 5 2 11807348 509,00

Page 152: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

300 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 301

Miniature Circuit-Breakers

4-POLE MCB

CURVE C, Im = 5 TO 10xI

n

TYPE In (A)

IEC898 230/400 V

Icn

(kA)

IEC947-2 230 V

Icu

(kA)PACKAGING STOCK CODE

PRICE EACH

(ZAR)

MDW-C6-4 6 3 5 3 10076403 207,00

MDW-C10-4 10 3 5 3 10076411 184,00

MDW-C16-4 16 3 5 3 10076419 184,00

MDW-C20-4 20 3 5 3 10076427 184,00

MDW-C25-4 25 3 5 3 10076435 184,00

MDW-C32-4 32 3 5 3 10076443 184,00

MDW-C40-4 40 3 5 3 10076451 184,00

MDW-C50-4 50 3 5 3 10076459 230,00

MDW-C63-4 63 3 5 3 10076467 230,00

MDW-C70-4 70 3 5 1 11134792 678,00

MDW-C80-4 80 3 5 1 10075741 678,00

MDW-C100-4 100 3 5 1 10075749 678,00

MDW-C125-4 125 3 5 1 11807349 678,00

ACCESSORIES FOR MINIATURE CIRCUIT BREAKERS

AUXILIARY CONTACT

PADLOCKING DEVICE

BUS BARS

BUS BAR ISOLATOR

TYPE AUX. CONTACTS TO USE WITH STOCK CODEPRICE EACH

(ZAR)

MDW-BC1 1 REV MDW (2 A-63 A) 10261573 70,00

MDW-BC2 1 REV MDW (70 A-100 A) 10261574 70,00

TYPE AUX. CONTACTS TO USE WITH PACKAGING STOCK CODEPRICE EACH

(ZAR)

MDW-PLW63 1 REV MDW (2 A-63 A) 50 11373980  Upon request 4)

MDW-PLW100 1 REV MDW (70 A-100 A) 50 11373981  Upon request 4)

TYPE CURRENT Ie Nº MCBS MCB PACKAGING STOCK CODE

PRICE EACH

(ZAR)

BR1 12 1) 63 12 MDW ((2 A-63 A) 10 11402519 56,00

BR1 54 1) 63 54 MDW (2 A-63 A) 1 m bar 11156854 187,00

BR2 6 2) 63 6 MDW (2 A-63 A) 10 11402518 109,00

BR2 27 2) 63 27 MDW (2 A-63 A) 1 m bar 11156855 381,00

BR3 4 3) 63 4 MDW (2 A-63 A) 10 11402457 142,00

BR3 18 3) 63 18 MDW (2 A-63 A) 1 m bar 11156857 499,00

AL-BR 63 - MDW (2 A-63 A) 20 11156853 22,00

TYPE MATERIAL APPLICATION Nº OF POLES MCB PACKAGING STOCK CODEPRICE EACH

(ZAR)

IS1 Plastic Bar side 1 50 11402911 206,00

IS2 Plastic Bar side 2 50 11402910 206,00

IS3 Plastic Bar side 3 50 11402909 206,00

IPB Plastic Bar pin Per pin 50 11863723 43,00

Note : Padlock is not supplied.

Note : 1) For single-pole breakers.

2) For 2-pole breakers.

3) For 3-pole breakers.

Note : 4) Upon Request.

Page 153: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

302 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 303

Miniature Circuit-Breakers

1-POLE MCB - HIGH CAPACITY

CURVE B, Im = 3 TO 5xI

n

CURVE C, Im = 5 TO 10xI

n

TYPE In (A)

IEC898 230/400 V

Icn

(kA)

IEC947-2 230/400 V

Icu

(kA)PACKAGING STOCK CODE

PRICE EACH

(ZAR)

MDWH-B6 6 10 10 12 11422529 121,00

MDWH-B10 10 10 10 12 11422579 121,00

MDWH-B16 16 10 10 12 11422583 121,00

MDWH-B20 20 10 10 12 11422587 121,00

MDWH-B25 25 10 10 12 11422631 121,00

MDWH-B32 32 10 10 12 11422636 121,00

MDWH-B40 40 10 10 12 11422640 135,00

MDWH-B50 50 10 10 12 11422644 135,00

MDWH-B63 63 10 10 12 11422658 135,00

TYPE In (A)

IEC898 230/400 V

Icn

(kA)

IEC947-2 230/400 V

Icu

(kA)PACKAGING STOCK CODE

PRICE EACH

(ZAR)

MDWH-C6 6 10 10 12 11422662 124,00

MDWH-C10 10 10 10 12 11422666 124,00

MDWH-C16 16 10 10 12 11422690 124,00

MDWH-C20 20 10 10 12 11422694 124,00

MDWH-C25 25 10 10 12 11422708 124,00

MDWH-C32 32 10 10 12 11422713 124,00

MDWH-C40 40 10 10 12 11422717 137,00

MDWH-C50 50 10 10 12 11422722 137,00

MDWH-C63 63 10 10 12 11422727 137,00

Miniature Circuit-Breakers

2-POLE MCB - HIGH CAPACITY

CURVE B, Im = 3 TO 5xI

n

CURVE C, Im = 5 TO 10xI

n

TYPE In (A)

IEC898 230/400 V

Icn

(KA)

IEC947-2 230/400 V

Icu

(kA)PACKAGING STOCK CODE

PRICE EACH

(ZAR)

MDWH-B6-2 6 10 10 6 11422543 247,00

MDWH-B10-2 10 10 10 6 11422580 247,00

MDWH-B16-2 16 10 10 6 11422584 247,00

MDWH-B20-2 20 10 10 6 11422628 247,00

MDWH-B25-2 25 10 10 6 11422632 247,00

MDWH-B32-2 32 10 10 6 11422637 247,00

MDWH-B40-2 40 10 10 6 11422641 274,00

MDWH-B50-2 50 10 10 6 11422645 274,00

MDWH-B63-2 63 10 10 6 11422659 274,00

TYPE In (A)

IEC898 230/400 V

Icn

(kA)

IEC947-2 230/400 V

Icu

(kA)PACKAGING STOCK CODE

PRICE EACH

(ZAR)

MDWH-C6-2 6 10 10 6 11422663 252,00

MDWH-C10-2 10 10 10 6 11422667 252,00

MDWH-C16-2 16 10 10 6 11422691 252,00

MDWH-C20-2 20 10 10 6 11422695 252,00

MDWH-C25-2 25 10 10 6 11422709 252,00

MDWH-C32-2 32 10 10 6 11422714 252,00

MDWH-C40-2 40 10 10 6 11422719 279,00

MDWH-C50-2 50 10 10 6 11422723 279,00

MDWH-C63-2 63 10 10 6 11422728 279,00

Page 154: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

304 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 305

Miniature Circuit-Breakers

3-POLE MCB - HIGH CAPACITY

4-POLE MCB - HIGH CAPACITY

CURVE B, Im = 3 TO 5xI

n

CURVE C, Im = 5 TO 10xI

n

CURVE C, Im = 5 TO 10xI

n

TYPE In (A)

IEC898 230/400 V

Icn

(kA)

IEC947-2 230/400 V

Icu

(kA)PACKAGING STOCK CODE

PRICE EACH

(ZAR)

MDWH-B6-3 6 10 10 4 11422546 372,00

MDWH-B10-3 10 10 10 4 11422581 372,00

MDWH-B16-3 16 10 10 4 11422585 372,00

MDWH-B20-3 20 10 10 4 11422629 372,00

MDWH-B25-3 25 10 10 4 11422634 372,00

MDWH-B32-3 32 10 10 4 11422638 372,00

MDWH-B40-3 40 10 10 4 11422642 413,00

MDWH-B50-3 50 10 10 4 11422646 413,00

MDWH-B63-3 63 10 10 4 11422660 413,00

TYPE In (A)

IEC898 230/400 V

Icn

(kA)

IEC947-2 230/400 V

Icu

(kA)PACKAGING STOCK CODE

PRICE EACH

(ZAR)

MDWH-C6-4 6 10 10 3 11422665 507,00

MDWH-C10-4 10 10 10 3 11422689 507,00

MDWH-C16-4 16 10 10 3 11422693 507,00

MDWH-C20-4 20 10 10 3 11422697 507,00

MDWH-C25-4 25 10 10 3 11422711 507,00

MDWH-C32-4 32 10 10 3 11422716 507,00

MDWH-C40-4 40 10 10 3 11422721 563,00

MDWH-C50-4 50 10 10 3 11422726 563,00

MDWH-C63-4 63 10 10 3 11422730 563,00

TYPE In (A)

IEC898 230/400 V

Icn

(kA)

IEC947-2 230/400 V

Icu

(kA)PACKAGING STOCK CODE

PRICE EACH

(ZAR)

MDWH-C6-3 6 10 10 4 11422664 379,00

MDWH-C10-3 10 10 10 4 11422688 379,00

MDWH-C16-3 16 10 10 4 11422692 379,00

MDWH-C20-3 20 10 10 4 11422696 379,00

MDWH-C25-3 25 10 10 4 11422710 379,00

MDWH-C32-3 32 10 10 4 11422715 379,00

MDWH-C40-3 40 10 10 4 11422720 421,00

MDWH-C50-3 50 10 10 4 11422725 421,00

MDWH-C63-3 63 10 10 4 11422729 421,00

Miniature Circuit-Breakers

ACCESSORIES FOR MINIATURE CIRCUIT BREAKERS - HIGH CAPACITY

AUXILIARY CONTACT

ALARM CONTACT

AUXILIARY CONTACT + ALARM CONTACT

SHUNT TRIP

TYPE AUX. CONTACT MCB PACKAGING STOCK CODE PRICE EACH

(ZAR)

MDWH-BC1 1 REV MDWH (6 A-63 A) 1 11882693 128,00

TYPE AUX. CONTACT MCB PACKAGING STOCK CODE PRICE EACH

(ZAR)

MDWH AL-1 1 REV MDWH (6 A-63 A) 1 11894565 156,00

TYPE AUX. CONTACT MCB PACKAGING STOCK CODE PRICE EACH

(ZAR)

MDWH AX-1 1 REV MDWH (6 A-63 A) 1 11894566 227,00

TYPE AUX. CONTACT MCB PACKAGING STOCK CODE PRICE EACH

(ZAR)

BS E25 MDWH6-63A 12 V ac/dc MDWH (6 A-63 A) 1 11894563 746,00

BS E31 MDWH6-63A 220 V ac/dc MDWH (6 A-63 A) 1 11894564 746,00

Page 155: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

306 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 307

Switches

EARTH LEAKAGE SWITCHES OR RESIDUAL CURRENT CIRCUIT BREAKERS - DRS

SWITCH DISCONNECTORS

TYPE In (A) IΔN (MA) POLES STOCK CODE

PRICE EACH

(ZAR)

RDW30-25-2 25 30 2 12276010 538,00

RDW30-40-2 40 30 2 12276012 538,00

RDW30-63-2 63 30 2 12276014 601,00

RDW30-80-2 80 30 2 10261527 940,00

RDW30-100-2 100 30 2 10075762 940,00

RDW30-25-4 25 30 4 12276041 831,00

RDW30-40-4 40 30 4 12276044 831,00

RDW30-63-4 63 30 4 12276046 650,00

RDW30-80-4 80 30 4 10261529 1067,00

RDW30-100-4 100 30 4 10075764 1081,00

RDW300-25-2 25 300 2 12276011 538,00

RDW300-40-2 40 300 2 12276013 538,00

RDW300-63-2 63 300 2 12276015 601,00

RDW300-80-2 80 300 2 10261528 940,00

RDW300-100-2 100 300 2 10075763 940,00

RDW300-25-4 25 300 4 12276042 831,00

RDW300-40-4 40 300 4 12276045 831,00

RDW300-63-4 63 300 4 12276047 747,00

RDW300-80-4 80 300 4 10261530 1067,00

RDW300-100-4 100 300 4 10075765 1081,00

TYPE In (A) POLES STOCK CODE

PRICE EACH

(ZAR)

SIW-40-2 40 2 10075767 74,00

SIW-63-2 63 2 10075770 74,00

SIW-80-2 80 2 10075773 238,00

SIW-100-2 100 2 10075776 238,00

SIW-40-3 40 3 10075768 111,00

SIW-63-3 63 3 10075771 111,00

SIW-80-3 80 3 10075774 356,00

SIW-100-3 100 3 10075777 356,00

SIW-40-4 40 4 10075769 148,00

SIW-63-4 63 4 10075772 148,00

SIW-80-4 80 4 10075775 475,00

SIW-100-4 100 4 10075778 475,00

HIGH SPEED FUSES

For short circuit protection of semiconductors / electronic equipment up to 690 Vac

AVAILABLE SIZES

NH range - sizes 00, 1, 2 and 3

GENERAL DATA

Fuse type: High Speed (aR), Square Body (NH)

Max. Application Voltage: 690 Vca 50/60 Hz

Short Circuit Breaking Capacity: 100 kA @ 690 Vca

Standard: IEC 60269

Certification:

High Speed Fuses

Overview

WEG aR fuses are available from 20 to 1000 A and were designed according to IEC 60269 and dimensional

requirements of DIN 43620.

Note:

WEG’s aR and gL/gG NH range fuses may be mounted in the same fuse base.

FUSE FUNCTIONING

In short circuits, the fuse element fuses, opening the electric circuit and interrupting the current flow.

The aR fuses are not designed to be used in short overloads, because they may act inappropriately.

During the short circuit, the fuse will limit the prospective short circuit current, according to the picture below:

I

Ip

tL

tts

Ic

Ic: Current limited by the fuse

ts: Pre-arc time

tL: Arc time

Ip: Prospective short circuit current

Page 156: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

308 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 309

High Speed Fuses

WEG high speed fuses are assembled in a high quality ceramic body, filled with impregnated quartz

sand, with silver fusing element and silvered copper blade terminals.

This assembly provides reduced I2t values and great electrical insulation, mechanical strength and

thermal shock resistance during the short circuit protection.

Silvered copper blade terminals:Ensures better coupling with

the fuse base with fewer losses

Fuse indicator:Indicates the breaking of the fusing element

Fuse data:Rated current, voltage, size, model, standard and certification

High quality ceramic enclosure:Endures the high pressure of the short circuit

High quality impregnated quartz sand:

Extincts the short circuit arc with low I2t values

Pure silver fusing element:For lower losses and faster fusing

High Speed Fuses

100kA / 690V

Technical characteristics

Reference Size Current [A]I²t - Ic I²t total - Ip Power loss [W]

@ 0.8 x In

690V [A²s]

FNH00-20K-A

00

20 16 240 3.2

FNH00-25K-A 25 19 255 3.5

FNH00-35K-A 35 23 430 5

FNH00-40K-A 40 56 580 7

FNH00-50K-A 50 130 1430 9

FNH00-63K-A 63 180 2170 10.5

FNH00-80K-A 80 270 2710 13.5

FNH00-100K-A 100 400 4530 14

FNH00-125K-A 125 810 6350 16.5

FNH00-160K-A 160 2100 15270 22.5

FNH00-200K-A 200 2900 25870 26.5

FNH00-250K-A 250 6200 43980 30.5

FNH1-63K-A

1

63 63 770 15

FNH1-80K-A 80 175 1610 19

FNH1-100K-A 100 320 3050 21

FNH1-125K-A 125 695 6360 25

FNH1-160K-A 160 1460 13090 29.5

FNH1-200K-A 200 2420 16380 34.5

FNH1-250K-A 250 4920 29810 40.5

FNH1-315K-A 315 7310 39590 48

FNH1-350K-A 350 11430 64870 52

FNH1-400K-A 400 16950 98860 59

FNH2-250K-A

2

250 3390 24370 45.5

FNH2-315K-A 315 4760 32780 57.5

FNH2-350K-A 350 7990 60150 66.5

FNH2-400K-A 400 14850 92060 77

FNH2-450K-A 450 18420 132990 91

FNH2-500K-A 500 23040 146250 103

FNH2-630K-A 630 49130 298820 127

FNH2-710K-A 710 57910 378450 137.5

FNH3-400K-A

3

400 6520 66830 70

FNH3-450K-A 450 15090 105220 74.5

FNH3-500K-A 500 18770 107200 79.5

FNH3-630K-A 630 32500 222540 94

FNH3-710K-A 710 56620 308900 105

FNH3-800K-A 800 87390 612850 117

FNH3-900K-A 900 129380 636150 130

FNH3-1000K-A 1000 197890 893350 150

I2t reduction factors for voltages under 690 Vac

Voltage Vac Applied factor

127 0.43

220 0.43

254 0.45

266 0.46

277 0.48

300 0.50

345 0.53

400 0.58

440 0.62

460 0.64

480 0.68

Page 157: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

310 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 311

aR Fuse Type “NH”

SEMICONDUCTOR SHORT-CIRCUIT PROTECTION FUSE - aR FUSE TYPE “NH”

TYPE SIZE CURRENT (A) PACKAGING STOCK CODEPRICE EACH

(ZAR)

FNH00-20K-A 0 20 3 10687494 188,00

FNH00-25K-A 0 25 3 10701722 188,00

FNH00-35K-A 0 35 3 10701721 188,00

FNH00-40K-A 0 40 3 10702117 188,00

FNH00-50K-A 0 50 3 10701718 188,00

FNH00-63K-A 0 63 3 10705764 250,00

FNH00-80K-A 0 80 3 10705995 250,00

FNH00-100K-A 0 100 3 10707110 250,00

FNH00-125K-A 0 125 3 10707231 250,00

FNH00-160K-A 0 160 3 10701724 287,00

FNH00-200K-A 0 200 3 10710732 287,00

FNH00-250K-A 0 250 3 10711445 287,00

FNH1-63K-A 1 63 3 10806688 504,00

FNH1-80K-A 1 80 3 10807549 504,00

FNH1-100K-A 1 100 3 10807553 504,00

FNH1-125K-A 1 125 3 10807554 504,00

FNH1-160K-A 1 160 3 10808545 565,00

FNH1-200K-A 1 200 3 10809133 565,00

FNH1-250K-A 1 250 3 10809489 565,00

FNH1-315K-A 1 315 3 10809575 565,00

FNH1-350K-A 1 350 3 10814896 674,00

FNH1-400K-A 1 400 3 10815073 674,00

FNH2-250K-A 2 250 3 10823581 845,00

FNH2-315K-A 2 315 3 10823936 845,00

FNH2-350K-A 2 350 3 10823996 1099,00

FNH2-400K-A 2 400 3 10824053 1099,00

FNH2-450K-A 2 450 3 10824055 1099,00

FNH2-500K-A 2 500 3 10824109 1173,00

FNH2-630K-A 2 630 3 10824110 1173,00

FNH2-710K-A 2 710 3 11393547 1173,00

FNH3-400K-A 3 400 3 10831217 1222,00

FNH3-450K-A 3 450 3 10832962 1222,00

FNH3-500K-A 3 500 3 10833056 1222,00

FNH3-630K-A 3 630 3 10833101 1339,00

FNH3-710K-A 3 710 3 10833591 1339,00

FNH3-800K-A 3 800 3 10833726 1626,00

FNH3-900K-A 3 900 3 11393564 1626,00

FNH3-1000K-A 3 1000 3 11393565 1626,00

gL/gG Fuse Type “NH”

ELECTRICAL CIRCUIT PROTECTION FUSE - gL/gG FUSE TYPE “NH”

TYPE SIZE CURRENT (A) PACKAGING STOCK CODEPRICE EACH

(ZAR)

FNH000-4U 0 4 3 10891504 181,00

FNH000-6U 0 6 3 10891107 181,00

FNH000-10U 0 10 3 10890978 181,00

FNH000-16U 0 16 3 10890945 181,00

FNH000-20U 0 20 3 10889723 181,00

FNH000-25U 0 25 3 10889565 181,00

FNH000-35U 0 35 3 10889349 181,00

FNH000-50U 0 50 3 10888901 181,00

FNH000-63U 0 63 3 10888698 181,00

FNH000-80U 0 80 3 10887824 212,00

FNH00-4U 0 4 3 10185934 194,00

FNH00-6U 0 6 3 10045369 194,00

FNH00-10U 0 10 3 10409880 194,00

FNH00-16U 0 16 3 10409881 194,00

FNH00-20U 0 20 3 10409882 194,00

FNH00-25U 0 25 3 10409883 194,00

FNH00-35U 0 35 3 10409884 194,00

FNH00-50U 0 50 3 10409885 194,00

FNH00-63U 0 63 3 10409886 194,00

FNH00-80U 0 80 3 10409887 212,00

FNH00-100U 0 100 3 10409888 212,00

FNH00-125U 0 125 3 10409889 212,00

FNH00-160U 0 160 3 10045370 233,00

FNH1-50U 1 50 3 10045371 430,00

FNH1-63U 1 63 3 10185935 430,00

FNH1-80U 1 80 3 10409890 430,00

FNH1-100U 1 100 3 10409891 430,00

FNH1-125U 1 125 3 10185936 451,00

FNH1-160U 1 160 3 10409892 451,00

FNH1-200U 1 200 3 10409893 540,00

FNH1-224U 1 224 3 10409894 540,00

FNH1-250U 1 250 3 10045372 540,00

FNH2-125U 2 125 3 10045373 627,00

FNH2-160U 2 160 3 10409895 627,00

FNH2-200U 2 200 3 10045374 627,00

FNH2-224U 2 224 3 10045375 627,00

FNH2-250U 2 250 3 10409896 627,00

FNH2-300U 2 300 3 10409897 760,00

FNH2-315U 2 315 3 10185937 760,00

FNH2-355U 2 355 3 10409898 760,00

FNH2-400U 2 400 3 10045376 949,00

FNH3-315U 3 315 3 10409899 949,00

FNH3-355U 3 355 3 10409900 949,00

FNH3-400U 3 400 3 10409901 949,00

FNH3-425U 3 425 3 10409902 949,00

FNH3-500U 3 500 3 10409903 949,00

FNH3-630U 3 630 3 10045377 1155,00

Page 158: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

312 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 313

Fuse Type “NH” and Accessories

FUSE EXTRACTOR HANDLE “NH”

FUSE BASE “NH”

SEPARATION BARRIER

TYPE PACKAGING STOCK CODEPRICE EACH

(ZAR)

PSFNH 1 10185944 860,00

TYPE SIZE PACKAGING STOCK CODEPRICE EACH

(ZAR)

PDNH00 0 2 10185940 43,00

PDNH1 1 4 10185941 157,00

PDNH2 2 4 10185942 170,00

PDNH3 3 4 10185943 332,00

TYPE SIZE CURRENT (A) PACKAGING STOCK CODEPRICE EACH

(ZAR)

BNH00-160 0 4-160 3 10409904 103,00

BNH1-250 1 50-250 3 10409905 423,00

BNH2-400 2 125-400 3 10185938 654,00

BNH3-630 3 315-630 3 10185939 911,00

Fuse-Switch-Disconnectors and Accessories - FSW

FUSE-SWITCH-DISCONNECTORS FSW

TERMINAL COVER

TYPE FUSE In (A) POLES STOCK CODE

PRICE EACH

(ZAR)

FSW 100-3 H NH000 100 3 11884107 735,00

FSW 160-3 H NH00 160 3 11884182 809,00

FSW 250-3 H NH1 250 3 11884179 2344,00

FSW 400-3 H NH2 400 3 11884180 3515,00

FSW 630-3 H NH3 630 3 11884181 4219,00

TYPE FUSE-SWITCH-DISCONNECTOR POLES STOCK CODEPRICE EACH

(ZAR)

FSW TS-100 FSW 100 3 11884546 29,00

FSW TS-160 FSW160 3 11884568 40,00

FSW TS-400 FSW250/FSW400 3 11884547 132,00

Page 159: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

314 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 315

Fuse Type “D” and Accessories

gL/gG FUSE TYPE “D”

ADAPTER SCREW “D”

FUSE BASE “D”

TYPE SIZE CURRENT (A) PACKAGING STOCK CODEPRICE EACH

(ZAR)

FDW-2S DII 2 36 10409856 32,00

FDW-4S DII 4 36 10409857 32,00

FDW-6S DII 6 36 10409858 32,00

FDW-10S DII 10 36 10409859 32,00

FDW-16S DII 16 36 10409860 32,00

FDW-20S DII 20 36 10409861 32,00

FDW-25S DII 25 36 10409862 32,00

FDW-35S DIII 35 36 10409863 46,00

FDW-50S DIII 50 36 10409864 46,00

FDW-63S DIII 63 36 10409865 46,00

TYPE SIZE CURRENT (A) PACKAGING STOCK CODEPRICE EACH

(ZAR)

PAW2 DII 2 12 10409870 25,00

PAW4 DII 4 12 10409871 25,00

PAW6 DII 6 12 10409872 25,00

PAW10 DII 10 12 10409873 25,00

PAW16 DII 16 12 10409874 25,00

PAW20 DII 20 12 10409875 25,00

PAW25 DII 25 12 10409876 25,00

PAW35 DIII 35 12 10409877 34,00

PAW50 DIII 50 12 10409878 34,00

PAW63 DIII 63 12 10409879 38,00

TYPE SIZE CURRENT (A) PACKAGING STOCK CODEPRICE EACH

(ZAR)

BAW25 1) DII 2-25 12 10409866 116,00

BSW25 2) DII 2-25 12 10045366 103,00

BAW63 1) DIII 35-63 12 10185932 154,00

BSW63 2) DIII 35-63 12 10409867 135,00

Note : 1) Includes base for fast mounting on 35 mm DIN rail.

2) Does not include base for fast mounting on 35 mm DIN rail.

Fuse Type “D” and Accessories

SCREW CAP “D”

FUSE BASE COVER “D”

PROTECTION COVER “D”

FIXING TOOL FOR “D” TYPE FUSE

TYPE SIZE CURRENT (A) PACKAGING (UN) STOCK CODEPRICE EACH

(ZAR)

TFW25 DII 2-25 12 10409868 51,00

TFW63 DIII 35-63 12 10409869 68,00

TYPE SIZE CURRENT (A) PACKAGING (UN) STOCK CODEPRICE EACH

(ZAR)

APW25 DII 2-25 12 10409906 13,00

APW63 DIII 35-63 12 10409907 18,00

TYPE SIZE CURRENT (A) PACKAGING (UN) STOCK CODEPRICE EACH

(ZAR)

CPFW25 DII 2-25 3 10045367 56,00

CPFW63 DIII 35-63 3 10045368 60,00

TYPE PACKAGING (UN) STOCK CODEPRICE EACH

(ZAR)

CPAW 1 10185933 24,00

Page 160: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

316 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 317

Switch-Disconnectors

The MSW Switch-Disconnectors were developed according to IEC 60947-3/UL 508, and enable the manual drive of motors,

machines and other equipment. Besides carrying and interrupting electric currents under normal or overload conditions, the

design of the MSW Switch-Disconnectors provides complete physical insulation between the circuit and the power supply

when in the OFF position.

In this position, it is possible to use three padlocks in order to prevent inadvertent actuation, increasing the safety of operators

and maintenance personnel.

The MSW Switch-Disconnectors are CE and UL certified, and can be used as the supply disconnecting device,

meeting the requirements of IEC 60204-1, and as the emergency switching off device. The MSW line presents a series of accessories and configurations. WEG offers the full set with a

standard configuration. The customer can select the Switch-Disconnectors and accessories according

to the requirements of each application. Below are described the four steps necessary for the proper

selection of the MSW Switch-Disconnector.

How to Select a MSW Switch-Disconnector for your Application

1 - MOUNTING

The MSW Switch-Disconnectors are mounted on panel doors or bases according to the selected model. Mounting on door: in this system, the Switch-Disconnector is mounted on panel doors by means of screws.

The Switch-Disconnector and the handle are always coupled. Mounting on base: the Switch-Disconnector is mounted on a base, like panel plates, by screws or DIN rail. There is a shaft

to couple the Switch-Disconnector to the handle. The uncoupling of the Switch-Disconnector and of the handle is only

possible when the Switch-Disconnector is in the OFF position.

The user must define the Switch-Disconnector considering the wiring, access, simple mounting or any other criteria which may

be deemed necessary.

2 - CURRENT

The Switch-Disconnector must present a rated current capacity equal to or above the rated current of the circuit/load.

The MSW Switch-Disconnectors stand currents (Ith) up to 160 A for base mounting and up to 100 A for door mounting,

according to the selected model. In order to select the Switch-Disconnector, some currents are presented in the references

according to the load characteristics. Other current values are presented in the table of technical data (page 319).

3 - HANDLE AND SHAFT

The handles of the MSW Switch-Disconnectors, developed with IP65 degree of protection, allow the use of up to three

padlocks when in the OFF position, ensuring safety during maintenance. The handles of the MSW line are available in the

colors red/yellow and black/grey.

For Switch-Disconnectors with base mounting, besides the handle, it is necessary to use a shaft. The shaft must have a length

equal to or longer than the distance between the Switch-Disconnector and the handle.

With those characteristics, it is possible to define a standard Switch-Disconnector, but WEG offers other accessories that may

be required for each application.

MountingDisconnection

required?Current

Handle

and ShaftAccessories

MSW Switch-

Disconnectorsdelivers!

Page 161: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

318 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 319

Switch-disconnector with 2 auxiliary contacts and

2 terminal covers.

4 - ACCESSORIES

4.a - NEUTRAL POLE

For applications that require neutral

disconnection the MSW line has an additional

pole with early make contact, that can be

assembled on the side of the Switch-

Disconnector.

4.b - AUXILIARY CONTACTS

The MSW line provides auxiliary contacts for

mounting on the sides of the Switch-

Disconnector. On each side of the Switch-

Disconnector, it is possible to mount an auxiliary

contact, or a neutral pole, as shown in the figure

on the left.

4.c - TERMINAL COVER

Aiming at enhancing the safety of machinery and

equipment, the MSW line provides terminal

covers that reduce the risk of inadvertent contact

with the terminals. The terminal covers must

cover all the poles with live conductors.

OVERVIEW

MountingCurrent

(A)

Handle Shaft (mm)Neutral pole

Auxiliary contact Terminal

coverRed/yellow Black/grey 85 185 300 1NO 1NC 1NOC

Panel door

32

40

63

80

100

Base

32

40

63

80

125

160

Notes: - Only available as part of the standard configuration.

- Available as part of the standard configuration or it can be supplied separately.

- Only available to be supplied separately.

Technical Data

IEC 60947-3 characteristics MSW 25 MSW 40 MSW 63 MSW 80 MSW 100 MSW 125 MSW 160 Auxiliary contact

Rated operating voltage Ue

V 690

Rated insulation voltage Ui

V 690 690 690 690 690 800 800 690

Rated impulse withstand voltage Uimp

(sectionable) kV 8 8 8 8 8 8 8 4

Rated thermal current Ith A 32 40 63 80 100 125 160 16

Rated thermal current in enclosed Ithe

A 32 40 63 80 86 125 160 10

Frequency Hz 50/60

Rated operating current Ie: alternate current

AC-21A switching resistive loads 690 V A 32 40 63 80 100 125 160 AC-15 240 V-5 A

AC-22A switching mixed resistive and inductive

loads

500 V A - - - - 100 125 160 DC-13 250 V-0.44 A

690 V A 25 32 63 80 86 125 160 -

AC-23A periodic switching of

motors

3 phase

3 poles

230 V A/kW 25/7.5 32/10 63/20 80/25 70/22 125/30 160/45 -

400 V A/kW 25/15 32/18.5 50/28 75/42 67/37 125/55 160/75 -

500 V A/kW 22/15 27/18.5 50/35 75/52 67/45 100/63 125/80 -

690 V A/kW 16/15 20/18.5 26/25 32/31 38/37 80/75 100/90 -

AC3 starting of cage motors

(interruption while running)

3 phase

3 poles

230 V A/kW 22/5.5 27/7.5 45/14 60/19 60/18.5 - - -

400 V A/kW 22/11 27/15 40/22 55/30 55/30 - - -

500 V A/kW 22/11 22/15 35/24 45/31 55/37 - - -

690 V A/kW 16/11 16/15 22/21 25/24 32/30 - - -

Rated interruption

current AC-23A

(cosfi 0.45)

230 V A 200 256 360 600 560 - - -

400 V A 200 256 320 536 536 1,000 1,280 -

500 V A 176 216 280 536 536 - - -

690 V A 128 160 176 256 304 800 800 -

Short circuit characteristics

Rated short-time short circuit withstand current Icw (1s) A 800 800 1,200 1,500 1,500 3,000 3,000 -

Rated short circuit making capacity Icm A 1,500 1,500 2,200 2,800 2,840 4,500 4,500 -

Conditional rated short circuit withstand current kA 10 10 10/5 10/5 10 15 15 1

Fuse rating gG500 V A - - - - 100 125 125 10

690 V A 40 40 63/80 63/80 - - - -

UL 508 characteristics

General use 600 V ac A 32 40 60 80 100 125 160 HD A600 ac

Q600 dc

Standard motors load

Single phase

2 poles

120 V ac hp (FLA) 1.5 (20) 2 (24) 2 3 3 (34) - - -

240 V ac hp (FLA) 3 (17) 5 (28) 5 7.5 10 (50) - - -

3 phase

3 poles

240 V ac hp (FLA) 7.5 (22) 10 (28) 10 15 10 (28) 40 (104) 40 (104) -

480 V ac hp (FLA) 10 (14) 15 (21) 25 30 25 (34) 100 (124) 100 (124) -

600 V ac hp (FLA) 15 (17) 20 (22) 30 40 30 (32) 125 (125) 125 (125) -

General characteristics

Protection degreeHandle EN 60529/UL 50 IP65 / Type 1-4-4X-NEMA 4X

Terminals EN 60529 IP20

Material group EN 60947-1 II IIIa IIIa II

Pollution grade EN 60947-1 3

Flammability UL 94 V0

Ambient temperatureOperation °C -25 +55

Storage °C -30 +70

Climate withstand

IEC 68

part 2-3Hot damp

IEC 68

part 2-30Unsetted hot damp

Switching force (3 poles) 0.8 Nm (7.1 lb.in.) 1 Nm (8.85 lb.in.) 1.5 Nm 2.6 (23 lb.in.) -

Connections EN 60947-1

Terminal block caliber A6 A8 - - A2

Terminal screw M4 M5 M8 M8 M3.5

Tightening torqueEN 60947-1 1.2 Nm 3 Nm 6 Nm 6 Nm 0.8 Nm

UL 508 10.6 lb.in. (1.2 Nm) 32 lb.in. (3.6 Nm) 53 lb.in. (6Nm) 7.1 lb.in.

Main terminal capacity mm² 1.5-10 6-25 10-70 10-70 1-2.5

Flexible conductorsAWG 12-6 10-2 3/0-6 3/0-6 18-12

mm² 1.5-16 10-35 10-70 10-70 1-2.5

Solid conductors AWG 12-6 10-2 3/0-6 3/0-6 18-12

Opening angles 90° -

Page 162: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

320 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 321

Panel Door Mounting Switch-Disconnectors and Accessories - MSW

STANDARD CONFIGURATION

TYPE Ith (A)

Ie 690 V (A)

POLES STOCK CODEPRICE EACH

(ZAR)AC21 AC22 AC23

MSW 25 P-3 H 32 32 25 16 3 11898918 402,00

MSW 40 P-3 H 40 40 32 20 3 11898886 428,00

MSW 63 P-3 H 63 63 63 26 3 11898922 663,00

MSW 80 P-3 H 80 80 80 32 3 11898923 768,00

MSW 100 P-3 H 100 100 86 38 3 11898945 958,00

TYPE Ith (A)

Ie 690 V (A)

POLES STOCK CODEPRICE EACH

(ZAR)AC21 AC22 AC23

MSW 25 P-3 32 32 25 16 3 11898714 267,00

MSW 40 P-3 40 40 32 20 3 11898883 294,00

MSW 63 P-3 63 63 63 26 3 11898884 528,00

MSW 80 P-3 80 80 80 32 3 11898885 634,00

MSW 100 P-3 100 100 86 38 3 11898887 824,00

TYPE SWITCH-DISCONNECTOR COLOUR STOCK CODEPRICE EACH

(ZAR)

MSW H 40 P MSW25/MSW40Red-yellow

11899507 115,00

MSW H 100 P MSW63/MSW80/MSW100 11899509 115,00

MSW H 40-P-B MSW25/MSW40Black-grey

12727302 Upon request

MSW H 100-P-B MSW63/MSW80/MSW100 12727304 Upon request

SWITCH-DISCONNECTORS WITH RED-YELLOW HANDLE

SWITCH-DISCONNECTORS WITHOUT HANDLE

ROTARY HANDLE

SWITCH-DISCONNECTORS AND ACCESSORIES

Panel Door Mounting Switch-Disconnectors and Accessories - MSW

TYPE SWITCH-DISCONNECTOR AUX. CONTACT STOCK CODEPRICE EACH

(ZAR)

MSW AC-40 P 1NC MSW25/MSW40 1NC 11899468 136,00

MSW AC-40 P 1NO MSW25/MSW40 1NO / NA 11899469 136,00

MSW AC-80 P 1NC MSW63/MSW80 1NC 11899472 136,00

MSW AC-80 P 1NO MSW63/MSW80 1NO / NA 11899476 136,00

TYPE SWITCH-DISCONNECTOR AUX. CONTACT STOCK CODEPRICE EACH

(ZAR)

MSW TS-40 P MSW25/MSW40 3 11899502 55,00

MSW TS-80 B/P MSW63/MSW80 3 11899504 109,00

MSW TS-100 P MSW100 2 11899505 109,00

AUXILIARY CONTACT

TERMINAL COVER

SWITCH-DISCONNECTORS AND ACCESSORIES

NEUTRAL POLE

TYPE SWITCH-DISCONNECTOR AUX. CONTACT STOCK CODEPRICE EACH

(ZAR)

MSW AP 25-P-1 NA MSW25

NO early make

12727286 150,00

MSW AP 40-P-1 NA MSW40 12727287 150,00

MSW AP 63-P-1 NA MSW63 12727300 177,00

MSW AP 80-P-1 NA MSW80 12727301 177,00

Note : Necessary 2x MSW TS-100P for cover 3 poles.

Page 163: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

322 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 323

Base Mounting Switch-Disconnectors and Accessories - MSW

STANDARD CONFIGURATION

TYPE Ith (A)

Ie 690 V (A)

POLES SHAFT (mm) STOCK CODEPRICE EACH

(ZAR)AC21 AC22 AC23

MSW 25 B-3 H 32 32 25 16 3 85 11898938 472,00

MSW 40 B-3 H 40 40 32 20 3 85 11898925 499,00

MSW 63 B-3 H 63 63 63 26 3 85 11898942 733,00

MSW 80 B-3 H 80 80 80 32 3 85 11898941 839,00

MSW 125 B-3 H 125 125 125 80 3 300 11898943 1714,00

MSW 160 B-3 H 160 160 160 100 3 300 11898944 1853,00

SWITCH-DISCONNECTORS WITH RED-YELLOW HANDLE + SHAFT

SWITCH-DISCONNECTORS AND ACCESSORIES

TYPE Ith (A)

Ie 690 V (A)

POLES STOCK CODEPRICE EACH

(ZAR)AC21 AC22 AC23

MSW 25 B-3 32 32 25 16 3 11898940 267,00

MSW 40 B-3 40 40 32 20 3 11898946 294,00

MSW 63 B-3 63 63 63 26 3 11898924 528,00

MSW 80 B-3 80 80 80 32 3 11898926 634,00

MSW 125 B-3 125 125 125 80 3 11898939 1394,00

MSW 160 B-3 160 160 160 100 3 11898927 1533,00

SWITCH-DISCONNECTORS WITHOUT HANDLE

TYPE SWITCH-DISCONNECTOR COLOUR SHAFT (mm) STOCK CODEPRICE EACH

(ZAR)

MSW H 40 B MSW25/MSW40

Red-yellow

85 11899512 173,00

MSW H 80 B MSW63/MSW80 85 11966588 173,00

MSW H 160 B MSW15/MSW160 300 11899515 271,00

MSW H 40-B-B MSW25/MSW40Black-grey

85 12727303 Upon request

MSW H 80-B-B MSW63/MSW80 85 12727305 Upon request

ROTARY HANDLE + SHAFT

Base Mounting Switch-Disconnectors and Accessories - MSW

SHAFT

NEUTRAL POLE

TYPE SWITCH-DISCONNECTOR LENGTH (mm) STOCK CODEPRICE EACH

(ZAR)

MSW HS 185-40 MSW25/MSW40 185 12030688 39,00

MSW HS 300-40 MSW25/MSW40 300 12030689 63,00

MSW HS 185-160 MSW63/MSW80/MSW125/MSW160 185 12030690 79,00

MSW HS 300-160 MSW63/MSW80/MSW125/MSW160 300 12030691 103,00

TYPE SWITCH-DISCONNECTOR CONTACT STOCK CODEPRICE EACH

(ZAR)

MSW AP 25-B-1 NA MSW25

NO early make

12727284 150,00

MSW AP 40-B-1 NA MSW40 12727285 150,00

MSW AP 63-B-1 NA MSW63 12727298 177,00

MSW AP 80-B-1 NA MSW80 12727299 177,00

TYPE SWITCH-DISCONNECTOR CONTACT STOCK CODEPRICE EACH

(ZAR)

MSW AC-40 B 1NC MSW25/MSW40 1NC 11899456 136,00

MSW AC-40 B 1NO MSW25/MSW40 1NO 11899457 136,00

MSW AC-80 B 1NC MSW63/MSW80 1NC 11899470 136,00

MSW AC-80 B 1NO MSW63/MSW80 1NO 11899471 136,00

MSW AC-160 B 1NONC MSW125/MSW160 1NOC 11899499 346,00

AUXILIARY CONTACT

TYPE SWITCH-DISCONNECTOR POLES STOCK CODEPRICE EACH

(ZAR)

MSW TS-40 B MSW25/MSW40 3 11899501 55,00

MSW TS-80 B/P MSW63/MSW80 3 11899504 109,00

MSW TS-160 B MSW125/MSW160 3 11899506 346,00

TERMINAL COVER

SWITCH-DISCONNECTORS AND ACCESSORIES

Page 164: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

324 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 325

Power Factor Controllers

The New Generation of WEG Components for Motor Starting and Protection

MMW - POWER METER

PFW01 - POWER FACTOR CONTROLLER

MMW - Power Meter

The MMW is a measuring device with microprocessor for the reading of programmed electric

magnitudes, replacing the individual digital and analog displays of voltage, current, power, among

others. It monitors and provides the measured and calculated values on Modbus RTU communication

network.

The MMW_-M performs the same functions afore mentioned, including a internal memory which allows

viewing previous measured and calculated electric magnitudes and events upon their programming.

TECHNICAL CHARACTERISTICS

Model MMW01 MMW01-M MMW02 MMW02-M

Electrical data

Power supply input (ac) 90 a 270 V ac 85 a 265 V ac

Power supply input (dc) 100 a 300 V dc 100 a 300 V dc

Consumption 10 VA 10 VA

Frequency 50 or 60 Hz (not both) 50 / 60 Hz (programmable)

Phase sequence indication Yes Yes

Phase sequence programmation No Yes (without wiring change)

CTs polarity programmation No Yes (without wiring change)

Current measurement input 0.05 - 5 A 0.05 - 5 A

Voltage measurement input 50 - 500 V ac 50 - 500 V ac

Mass memory - Standard - Standard

Memory capacity - 256 Kb - 16 Mb

Minimum register interval - 250 ms - 1 sec

Data storage mode - Linear or circular - Linear or circular

Electric magnitudes stored - 30 - all

Measuring elements 2 or 3 2 or 3

Alarm output Relay contact - 10 VA / 250 V ac Relay contact - 10 VA / 250 V ac

Electrical conections (wiring) Delta / star 21 types (delta / star)

Help function No Yes

Language Portuguese Portuguese / spanish / english

Mechanical data

Conection terminals Eyelet terminal Eyelet terminal

Dimensions - HxWxD (mm) 144x144x86 96x96x84

Panel cutout - HxW (mm) 136x136 91x91

Display Cristal liquid 2 lines x 20 columns (40 characters) Cristal liquid 4 lines x 16 columns (32 characters)

Backlight Yes Yes

Degree of protection IP40 IP40

Constructive material Thermoplastic ABS Thermoplastic ABS

Assembly Panel door Panel door

Aprox. weight 0.8 Kg 0.9 Kg 0.43 Kg

Keyboard 8 multifunctionals buttons 12 multifunctionals buttons 6 multifunctionals buttons

Storage temperature -25 °C to 75 °C -25 °C to 75 °C

Operational temperature 0 °C to 55 °C 0 °C to 60 °C

Communication

Nr. of ports 1 2 1

Type 1 x RS485 1 x RS485 / 1 x RS232 1 x RS485

Protocol Modbus-RTU Modbus-RTU

Com. speed 9.6 /19.2 / 38.4 Kbps 600 to 115,200 bps

Data format 8N1 8N1, 8N2, 8E1, 8E2, 8O1, 8O2

Parameterization software WEG Power Manager WEG Power Manager

Accuracy 1)

Voltage 0.5% ±0.2% ±0.05

Current 0.50% 1% ±0.2% ±0.05

Power factor 2% 1% 1

Electric power 2% 1% Class B (active) and C (reactive)

Energy consumption 2% 1% Class B (active) and C (reactive)

THD - ±1%

Frequency 0.5% ±0.04%

Note: 1) In relation to full scale.

Page 165: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

326 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 327

MMW - Power Meter

Screen of the WEG Power Manager

WEG POWER MANAGER

For a graphical analysis and tabulation of measured and stores electric data, the WEG Power Manager software application

goes along with the MMW.

Through this tool, you can produce graphs and reports of all electric magnitudes measured and calculated by the MMW.

Besides, all the parameterization can be done by the application.

The table below shows the magnitudes available via display and software.

Electrical magnitudes

MMW01 MMW01-M MMW02 MMW02-M

Display DisplayMemory

register

SoftwareDisplay Display

Memory

register

Software

Report Report

Line and phase voltage - and three-phase average (V)

Max. and min. voltages (V) - - - -

Phase current and average (A)

Neutral current (A) - - -

Max. and min. currents (A) - - - -

Power factor per phase (cos Ø) and three-phase

average

Max. and min. power factors (cos Ø) - - - -

Active power consumption / total active power (kWh)

Reactive consumption / total reactive power (kVArh)

Total active demand (kW)

Total reactive demand (kVAr)

Instant active power per phase and average (kW)

Instant reactive power per phase and average (kVAr)

Instant apparent power per phase and average (kVA)

Phase frequency 1 (Hz)

Voltage THD (%)

Current THD (%)

Voltage odd harmonics (%) - - -

Current odd harmonics (%) - - -

Voltage even harmonics (%) - - - - - - -

Current even harmonics (%) - - - - - - -

Phase sequence - - - - - -

CTs polarity - - - - - -

SCREEN OF THE WEG POWER MANAGER

AVAILABLE CONNECTIONS

Please consult the Installation Manuals available at our website (www.weg.net) for the possible connections (wiring) for each

Power Meter model.

ALARM CONNECTION

The alarm output is a relay contact (NO, 10 A @ 250 V ac). For loads greater than the specification, an external auxiliary relay or

contactor must be used.

SERIAL COMMUNICATION

The MMW provide a RS485 output for their use in a communication network. The connection in network allows monitoring the

electric magnitudes of several points by means of the WEG software or another software application developed with Modbus-

RTU protocol.

MMW - Power Meter

7 8

D-D+ D+

D+ D+

D+

D+

Converter

232 / 485

D-

D-D-D-

D-

RS485

88 77

88 77

Alarm

L1

LoadExternal Filte

100R

0,1u F

L2

L3

N

Page 166: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

328 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 329

DIMENSIONS

FRONT DIMENSIONS (mm)PANEL CUTOUT

H2

L2

L1

FRONT

H1

Description L1 H1 L2 H2 Depth

MMW01 144 144 136 136 90

MMW01-M 144 144 136 136 86

MMW02 98 98 91 91 101

MMW02-M 98 98 91 91 101

BACK VIEW - CONNECTIONS

MMW01

Group Connection Description

V

1 Voltage V1 +

2 Voltage V1 -

3 Voltage V2 +

4 Voltage V2 -

5 Voltage V3 +

6 Voltage V3 -

I

7 Current I1 +

8 Current I1 -

9 Current I2 +

10 Current I2 -

11 Current I3 +

12 Current I3 -

I/O13 Relay NO RLA

14 Relay NO RLB

COM15 RS485 D +

16 RS485 D -

AUX17 Voltage V1 +

18 Voltage V1 -

1 2 3 4 5 6 7 8 9 10 11 12

13 14 15 16 17 18 19 20 21 22 23 24

+ V1 - + V2 - + V3 -

A RL B + I1 - + I2 - + I3 -

+ Vaux -

D+ D-

MMW01-M

1 2 3 4 5 6 7 8

17 18 19 20 21 22 23 24 25 26

+ V1 - + V2 - + V3 -A RL B 9 10 11 12 13 14 15 16

+ I1 - + I2 - + I3 - + IN -

+ Vaux - GND TxD RXD D+ D-

Made in Brazil

Group Connection Description

I/O

1 NO relay RLA

2 NO relay RLB

3 -

I

4 Current I1 +

5 Current I1 -

6 Current I2 +

7 Current I2 -

8 Current I3 +

9 Current I3 -

10 -

COM11 RS485 D +

12 RS485 D -

V

13 Voltage V1 +

14 Voltage V1 -

15 -

16 Voltage V2 +

17 Voltage V2 -

18 -

19 Voltage V3 +

20 Voltage V3 -

21 -

AUX

22 Supply Vaux +

23 -

24 Supply Vaux -

Group Connection Description

AUX

1 Supply Vaux +

2 Supply Vaux -

3 -

COM

4 RS232 GND

5 RS232 TxD

6 RS232 RxD

7 RS485 D +

8 RS485 DI

I

9 Current I1 +

10 Current I1 -

11 Current I2 +

12 Current I2 -

13 Current I3 +

14 Current I3 -

15 Current IN +

16 Current IN -

I/O 17 Relay NO RLA

18 Relay NO RLB

V

19 Voltage V1 +

20 Voltage V1 -

21 -

22 Voltage V2 +

23 Voltage V2 -

24 -

25 Voltage V3 +

26 Voltage V3 -

MMW02 / MMW02-M

MMW - Power Meter PFW01 - Power Factor Controller

SELECTION CODE

The PFW01 is a Power Factor Controller with microprocessor which, besides eliminating or reducing penalties and losses

in your system for low power factor, allows the monitoring of electric magnitudes of your installation.

CHARACTERISTICS

CONTROL Power factor Minimum current - activates kvar programmed for minimum consumptio

Example: idle transformer Control for harmonics distortion filter - activates output 1 and turns on the external THD filter

MEASUREMENTS Power factor Voltage and current rms Total and individual voltage harmonics distortion Active power System reactive power Apparent power Required reactive power Frequency

ALARMS Maximum and minimum voltage Maximum and minimum current Maximum and minimum power factor Total voltage harmonics distortion

COMMUTATION OF THE CAPACITOR BANKThe commutation of the banks on the PFW01 is done manually our automatically.

AUTOMATIC MODE Powers equal to the steps - PFW01 drives first the banks with the lower number of operations, avoiding excessive switching

in a single step, and operates in a rotating way Powers different from the steps - PFW01 activates the bank according to the reactive power required by the system

Code Steps

06 6 steps

12 12 steps

Code Measurement

M Single-phase

T Three-phase

PFW01 - M 06NUMBER OF STEPS

TYPE OF MEASUREMENT

POWER FACTOR CONTROLLER

Reference Measurement Number of steps Power supply Frequency

PFW01-M06 Single-phase 06 85-265 V ac 50 or 60 Hz - different products

PFW01-M12 Single-phase 12 85-265 V ac 50 or 60 Hz - different products

PFW01-T06 Three-phase 06 90-270 V ac 50 or 60 Hz - different products

PFW01-T12 Three-phase 12 90-270 V ac 50 or 60 Hz - different products

Page 167: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

330 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 331

PFW01 - Power Factor Controller

Description PFW01 - Three-phase PFW01 - Three-phase

Operating mode Automatic or manual Automatic

Front dimensions - height x width 98 mm x 98 mm 144 mm x 144 mm

Depth 100 mm 86 mm

Opening on the panel - height x width 91 mm x 91 mm 136 mm x 136 mm

LCD 2 lines x 16 columns 2 lines x 20 columns

Operating temperature 0 a 55 ºC 0 to 55 ºC

Storage temperature -25 ºC to 75 ºC -25 ºC to 75 ºC

Weight 0.5 kg 0.9 kg

Degree of protection IP40 IP40

Power supply input 85 to 265 V ac 90 to 270 V ac

Measurement voltage input 50 to 500 V ac 50 to 500 V ac

Current input 0.05 to 5 A through TC 0.05 to 5 A through TC

Frequency 60 Hz 45 to 65 Hz

Number of steps - relays 06 and 12 06 and 12

Drive capacity per step - relay 1A - 105 VA, 250 V ac 1 A - 105 VA, 250 V ac

Alarm output - relay 1A - 105 VA, 250 V ac 1 A - 105 VA, 250 V ac

Reading range power factor 0.5 i to 0.5 c 0.5 i to 0.5 c

Consumption 10 VA 10 VA

Serial communication - RS485 - Modbus RTU

Communication speed - 9600, 19200 and 38400 b/s

Measurement V, A, W ,VA, var, THDv, FP V, A, W, VA, var, THDv, FP

Terminal type Pluggable connection Pluggable connection

Maximum acceptable section - terminal 2.5 mm2 2.5 mm2

Screw type of the terminal Slot - 3.5 mm Slot - 3.5 mm

Memory Non-volatile - retentive Non-volatile - retentive

PFW01-M06 PFW01-M12

STAR CONNECTION - PHASE NEUTRAL

In star connections, the voltage and current sensors must be connected to the same phase. Below is an example of

connection using phase L1 (R).

Note: whenever possible use this type of connection.

Attention: do not power up the capacitor switching

contacts on the same supply phase of the PFW01.

AVAILABLE CONNECTIONS – SINGLE-PHASE MODEL

V1 V2

60-260 V

Atenção

X1 NC NCX2 S1 S2 A1 A2

Alarme

Saídas de controle

Made in Brasil

CorrenteTensão

2

L1

Consum

o /

Carg

a

(R)(S)(T)

L2L3

N

1 3 4 5 6 7 8 9 10 11 12 C

2160D

4B

PFW01-M06 PFW01-M12

DELTA - PHASE - PHASE CONNECTION

In delta connections, the voltage and current sensors must be connected with a displacement of 90º. The example below

shows the connection using the voltage of phases L2 (S) and L3 (T) and the current of phase L1 (R).

AVAILABLE CONNECTIONS – THREE-PHASE MODEL

PFW01-T06 PFW01-T12

CURRENT SENSOR - PFW01-T06 AND PFW01-T12

Make sure that the TC polarity is not inverted and its common is not connected to another application. It is also mandatory the

connection in the correct order of phase R (V1), phase S (V2) and phase T (V3). Connect the TCs to the terminals as shown in

the figure below.

Note: whenever possible use this type of connection.

V1 V2

60-260 V

ATENÇÃO

X1 NC NCX2 S1 S2 A1 A2ALARME

SAÍDAS DE CONTROLE

Made in Brasil

CORRENTETENSÃO

2

L1(R)(S)(T)

L2L3N

1 3 4 5 6 7 8 9 10 11 12 C

21

60

D4

B

l1 l2 l3

R

Network

Terminals

Ground

S

T

N

PFW01 - Power Factor Controller

AVAILABLE CONNECTIONS – SINGLE-PHASE MODEL

Page 168: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

332 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 333

VOLTAGE SENSOR - PHASE-NEUTRAL WITHOUT TP - STAR CONNECTION

PFW01-T06 PFW01-T12

CURRENT SENSOR - PFW01-T06 AND PFW01-T12

When the PFW01 is programmed for measurement with two (2) TCs, it is not necessary the connection of the TC related to phase S

(I2). However, in this configuration of two TCs, the current of phase S will be calculated and not measured, considering that the

network is balanced.

VOLTAGE SENSOR - PFW01-T06 AND PFW01-T12

Make sure the TP polarity is not inverted. It is also mandatory the connection in the correct order of phase V1, phase V2 and phase

V3. Connect the TPs to the terminals according to the necessary connection choosing one of the diagrams below.

VOLTAGE SENSOR PHASE-NEUTRAL WITH TP - STAR CONNECTION

Phase-Neutral S/TP. Star connection

V1 V2 V3

R

Terminals

Network

S

T

N

Phase-Neutral C/TP. Star connection

R

V1 V2 V3

Terminals

Network

S

T

N

PFW01 - Power Factor Controller

AVAILABLE CONNECTIONS – THREE-PHASE MODEL

VOLTAGE SENSOR-PHASE-PHASE WITH TP - DELTA CONNECTION

PFW01-T06 PFW01-T12

VOLTAGE SENSOR-PHASE-PHASE WITHOUT TP - DELTA CONNECTION

VOLTAGE SENSOR-PHASE-PHASE WITH 2 TPS - DELTA CONNECTION

Phase-Neutral S/TP. Delta connection

Phase-Neutral C/TP. Delta connection.

Phase-Neutral C/TPs. Delta connection

V1 V2 V3

R

Terminals

Network

S

T

N

R

V1 V2 V3

Terminals

Network

S

T

N

R

V1 V2 V3

Terminals

Network

S

T

N

PFW01 - Power Factor Controller

AVAILABLE CONNECTIONS – THREE-PHASE MODEL

Page 169: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

334 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 335

PFW01-M06 PFW01-M12

PFW01-T06 PFW01-T12

PANEL CUTOUT

Depth = 100 mm

FRONT

98

mm

98 mm

PANEL CUTOUT

Depth = 90 mm

91

mm

91 mm

13

6 m

m

136 mm

FRONT

144 mm

FRONT

14

4 m

m

PFW01-M06 PFW01-M12

BACK VIEW - CONNECTIONS

PFW01-T06 PFW01-T12

DIMENSIONS

PFW01 - Power Factor ControllerTYPE DESCRIPTION STOCK CODE

PRICE EACH

(ZAR)

PFW01-M06 POWER FACTOR CONTROLLER PFW01-M06-50 12240101 7825,00

PFW01-M12 POWER FACTOR CONTROLLER PFW01-M12-50 12240107 8764,00

PFW01-T06 POWER FACTOR CONTROLLER PFW01-T06-50 12240102 11894,00

PFW01-T12 POWER FACTOR CONTROLLER PFW01-T12-50 12240168 12676,00

MMW02-50/60Hz MULTIFUNCTION METER MMW02-50/60Hz 12472815 7199,00

MMW02-M-50/60Hz MULTIFUNCTION METER MMW02-M-50/60Hz 12472814 9390,00

POWER FACTOR CONTROLLER

Page 170: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

336 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 337

WEG has played an important role in the electric industry raising the quality and process bar to the highest level since it began

the production of the most elementary switch and control gear devices for electric motors. As a result, WEG presents its series

of Capacitors for Power Factor Correction, which are assembled according to national and international standards such as NBR

IEC 60831 parts 1 and 2, EN IEC 60831 parts 1 and 2 and UL 810. WEG’s production chain also includes the

ISO 9001 and 14001 certifications.

Power Factor Correction

Capacitors: The Technology Within

During their useful life, the capacitors may be subjected

to certain utilization conditions, such as electrical and

thermal overloads (voltage surges, short circuits, harmonics,

excessive switching, high ambient temperature), which can

damage them prematurely.

Due to the utilization conditions mentioned above, WEG

capacitors are assembled with a high performance and low

loss self-healing polypropylene dielectric film providing two

important characteristics: Low Watt losses: dielectric losses smaller than 0.2 W / kvar; Self-healing properties: in application conditions that

cause a short circuit fault in the dielectric, the self-healing

effect quickly reestablishes its electric properties.

As shown in the picture below, obtained through microscopic

magnification, when there is a fault in the dielectric, the

metallic layer above the polypropylene film vaporizes around

the rupture point isolating the short circuit. This happens

because at the moment of short circuit , the metal layer

around the fault is subjected to high temperatures. This is the

self-healing effect.

POLYPROPYLENE FILM AFTER SELF-HEALING EFFECT

Rupture of dielectric area

Area where self-healing occurred (metal vaporization)

Isolated area, which

increases distance between

rupture area and conductive

layer

Self-healing polypropylene film

conductive layer

Rupture of dielectric area

(magnified 1,000 times)

The reduction of the capacitance after the self-healing is so small that it can only be verified with precise measurements and the

capacitor remains operating normally after each self-healing. The cumulative effect of the self-healing will result in the increase of

its internal pressure up to the point of the end of its life.

To avoid possible damage to the electric installation caused by over-pressure in the capacitor, the polypropylene WEG

capacitors are specially designed for power factor correction and have a safety system against internal over-pressures. This

safety system has the function of interrupting the electric current on the capacit and when the internal pressure is too high.

The actuation of this system normally occurs in the end of the life of the capacitor or in cases of overload conditions.

The aluminum enclosures used on WEG capacitors are made from a specific aluminum alloy assuring greater durability, better

thermal dissipation and a perfect actuation of the safety system against over-pressure.

To protect the capacitive element from the influence of the external environment (humidity and other impurities), as well as

assuring proper heat dissipation and a longer useful life to WEG capacitors, the capacitive element is mounted on the aluminum

enclosure and filled with a special non-poisonous oil. WEG capacitors are PCB free.

The internal over-pressure caused by the cumulative of self-healing effect of the polypropylene film will create a force on the

internal walls of the capacitor. This force will act on the expandable grooves (capacitive units with plastic closing top) or on the

metallic cover resulting in the breaking of the “mechanical fuse” and, consequently, disconnecting the capacitor from the power

source. This mechanism provides total protection against over-pressure.

WEG SAFETY SYSTEM

WEG SAFETY SYSTEM IN PLASTIC COVERS WEG SAFETY SYSTEM IN METALLIC COVERS

Breaking area

(connected)

Breaking area

(disconnected)

Expandable groove

(expanded)

Expandable groove

(normal)

Normal Expanded

Breaking area

(connected)

Breaking area

(disconected)

Detail A Detail B

Normal Expanded

Expansion of

cover

Detail A Detail B

Max. 20 mm

Page 171: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

338 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 339

A Series

Single Phase Capacitive Units - UCW

Power 0.62...0.83 (kvar)

Rated Voltage 380...535 (V)

Mounting

Fast-on connection terminals for connection of power cables

and discharge resistors. Double fast-on allowing the connection of power cables

separately from discharge resistors. Grounding is assured by connection of capacitive unit fixing bolt

with assembly plate.

DIMENSIONAL (MM) AND PROTECTION DEGREE

Diameter (Ø) Height (H) Protection degree Size code

40 85 IP00 G4

40 105 IP00 G6

ELECTRICAL CONNECTION

>20 mm

M8 bolt fixing

(nut and washer not

included in UCW) 1)

Horizontal mounting Vertical mounting

>20 mm

6.3

9.10

0.80

M8 b lt fi i

16 13.5H

M8 Ø

Note: 1) The grounding cable must be connected directly to the capacitor fixing screw or the capacitor must be fixed on a grounded base.

9.10

6.3

0.80

B Series

Single Phase Capacitive Units - UCW

Power 0.62...3.3 (kvar)

Rated Voltage 208...240 (V)

Power 0.62...6.67 (kvar)

Rated Voltage 380...535 (V)

Electrical Connection

MOUNTING

M3 Flat/Philips screw terminals for connection of power

cables. Fast-on connection terminals for discharge resistor

connection. Allows connection of power cables separately from

discharge resistors. Grounding is assured by connection of capacitive unit fixing

bolt with assembly plate.

DIMENSIONAL (MM) AND PROTECTION DEGREE

16 13.5H

M12 Ø

Diameter (Ø) Height (H) Protection degree Size code

53 68 IP00 J2

53 85 IP00 J4

53 105 IP00 J6

53 141 IP00 J8

60 85 IP00 L4

60 105 IP00 L6

60 141 IP00 L8

60 156 IP00 L10

70 156 IP00 M10

M12 bolt fixing

(nut and washer not

included in UCW) 1)

>20 mm

Horizontal mounting Vertical mounting

>20 mm

Note: 1) The grounding cable must be connected directly to the capacitor fixing screw or the capacitor must be fixed on a grounded base.

Page 172: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

340 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 341

C Series

Single Phase Capacitive Units - UCW

Power 3.72...6.67 (kvar)

Rated Voltage 208...240 (V)

Power 5.56...10 (kvar)

Rated Voltage 380...535 (V)

“Box” type terminals for connection of power cables. Fast-on connection terminals for discharge resistor

connection (discharge resistor included). Allows the connection of power cables separately from

discharge resistors. Grounding is assured by connection of capacitive unit fixing

bolt with assembly plate.

Diameter (Ø) Height (H) Protection degree Size code

75 205 IP20 N14

DIMENSIONAL (MM) AND PROTECTION DEGREE

ELECTRICAL CONNECTION

MOUNTING

M12 bolt fixing

(nut and washer included) 1)

>20 mm

>20 mm

Vertical mounting

1645 H

Ø M12

Note: 1) The grounding cable must be connected directly to the capacitor fixing screw or the capacitor must be fixed on a grounded base.

D Series

Three Phase Capacitive Units - UCWT

Power 0.37...3 (kvar)

Rated Voltage 208...240 (V)

Power 0.37...5 (kvar)

Rated Voltage 380...535 (V)

ELECTRICAL CONNECTIONS

MOUNTING

Provided with IP50 protection cover. M3 Flat/Philips screw terminals for connection of power cables. Internal discharge resistor in capacitive cell. Grounding is assured by connection of capacitive unit fixing bolt

with assembly plate.

Diameter (Ø) Height (H) Protection degree Size code

60 156 IP50 L10

60 211 IP50 L16

DIMENSIONAL (MM) AND PROTECTION DEGREE

M12 bolt fixing

(nut and washer included) 1)

>20 mm

Horizontal mounting Vertical mounting

>20 mm

H

Ø

M12

16

72

35

Note: 1) The grounding cable must be connected directly to the capacitor fixing screw or the capacitor must be fixed on a grounded base.

Page 173: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

342 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 343

E Series

Three Phase Capacitive Units - UCWT

Power 3.72...15 (kvar)

Rated Voltage 208...240 (V)

Power 5.56...25 (kvar)

Rated Voltage 380...535 (V)

“Box” type terminals for connection of power cables.

Fast-on connection terminals for discharge resistor

connection.

Allows connection of power cables separately from

discharge resistors.

Grounding is assured by connection of capacitive unit fixing

bolt with assembly plate.

DIMENSIONAL (MM) AND PROTECTION DEGREE

ELECTRICAL CONNECTIONS

MOUNTING

1645 H

M12

Ø

Diameter (Ø) Height (H) Protection degree Size code

75 225 IP20 N20

75 285 IP20 N22

85 285 IP20 O22

85 360 IP20 O24

M12 bolt fixing

(nut and washer included) 1)

>20 mm

>20 mm

Vertical mounting

Note: 1) The grounding cable must be connected directly to the capacitor fixing screw or the capacitor must be fixed on a grounded base.

F Series

Three Phase Capacitive Units - UCWT

Power 7.45...20 (kvar)

Rated Voltage 208...240 (V)

Power 11.12...35 (kvar)

Rated Voltage 380...535 (V)

Flexible installation and connection. “Box” type terminals for connection of power cables. Fast-on connection terminals for discharge resistor connection. Allows connection of power cables separately from discharge

resistors. Grounding is assured by connection of capacitive unit fixing bolt

with assembly plate.

DIMENSIONAL (MM) AND PROTECTION DEGREE

ELECTRICAL CONNECTIONS

MOUNTING

1645 H

Ø

M12

Diameter (Ø) Height (H) Protection degree Size code

100 230 IP20 Q26

116 230 IP20 S26

116 290 IP20 S28

M12 bolt fixing(nut and washer included) 1)

>20 mm

>20 mm

Vertical mounting

Note: 1) The grounding cable must be connected directly to the capacitor fixing screw or the capacitor must be fixed on a grounded base.

Power 7.45...15 (kvar)

Rated voltage 208...240 (V)

Power 11.12...25 (kvar)

Rated voltage 380...535 (V)

Power 17.5...20 (kvar)

Rated voltage 208...240 (V)

Power 30...35 (kvar)

Rated voltage 380...535 (V)

Page 174: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

344 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 345

Three Phase Capacitive Module - MCW

Power 1.86...10 (kvar)

Rated Voltage 208...240 (V)

Power 1.85...15 (kvar)

Rated Voltage 380...535 (V)

MODULE CONNECTION IN PARALLEL Voltage up to 240 V:

It is possible to connect up to 3 MCW modules in parallel

using connection BI-MCW bars.

For voltages from 208 V to 240 V, it is possible to

compensate up to 30 kvar.

Voltage equal or higher than 380 V:

It is possible to connect up to 4 MCW modules in parallel

using BI-MCW bars.

For voltages from 380 V to 535 V, it is possible to

compensate up to 60 kvar.

DIMENSIONAL (MM) AND PROTECTION DEGREE

Mounting

H

L W

Number of modulesDimensions

(L x W x H)Protection degree

1 219 x 78 x 257 IP40

2 219 x 156 x 257 IP40

3 219 x 234 x 257 IP40

4 219 x 312 x 257 IP40

Module horizontal mounting

360o

Module vertical mounting

Capacitors for Power Factor Correction

UCW - SINGLE PHASE CAPACITOR UNIT

VOLTAGE (V)

50 Hz 60 HzCAPACITANCE

(uF)SERIES TYPE

DIMENSIONS

ØxH (mm)DISCHARGE RESISTOR STOCK CODE

PRICE EACH

(ZAR)kVAr kVAr

208

0,62 0,74 45,5 B UCW0.83V25 J4 53x85 Not included 11488457 250,00

0,62 0,74 45,5 B UCW0.83V25 L6 60x105 Not included 10045809 260,00

1,24 1,49 91,5 B UCW1.67V25 L6 60x105 Not included 10045802 347,00

1,86 2,23 137 B UCW2.5V25 L10 60x156 Not included 10045950 399,00

2,48 2,98 182,5 B UCW3.33V25 L10 60x156 Not included 10046652 495,00

3,72 4,47 274 C UCW5V25 N14 75x205 Included 11449885 1101,00

4,97 5,96 365,6 C UCW6.67V25 N14 75x205 Included 11507565 1370,00

220

0,69 0,83 45,5 B UCW0.83V25 J4 53x85 Not included 11488457 250,00

0,69 0,83 45,5 B UCW0.83V25 L6 60x105 Not included 10045809 260,00

1,39 1,67 91,5 B UCW1.67V25 L6 60x105 Not included 10045802 347,00

2,08 2,5 137 B UCW2.5V25 L10 60x156 Not included 10045950 399,00

2,78 3,33 182,5 B UCW3.33V25 L10 60x156 Not included 10046652 495,00

4,17 5 274 C UCW5V25 N14 75x205 Included 11449885 1101,00

5,56 6,67 365,6 C UCW6.67V25 N14 75x205 Included 11507565 1370,00

230

0,83 1 49,9 B UCW0.83V34 L6 60x105 Not included 10072341 259,00

1,67 2 100,5 B UCW1.67V34 L8 60x141 Not included 10046044 352,00

2,5 3 150,4 B UCW2.5V34 L10 60x156 Not included 10046045 414,00

3,33 4 200,4 B UCW3.33V34 L10 60x156 Not included 11559336 465,00

5 6 300,9 C UCW5V34 N14 75x205 Included 11507589 1136,00

240

0,69 0,83 38,2 B UCW0.83V29 L6 60x105 Not included 10048213 339,00

1,39 1,67 76,9 B UCW1.67V29 L6 60x105 Not included 10045987 347,00

2,08 2,5 115,1 B UCW2.5V29 L8 60x141 Not included 10045988 399,00

2,78 3,33 153,4 B UCW3.33V29 L10 60x156 Not included 10076158 495,00

4,17 5 230,3 C UCW5V29 N14 75x205 Included 12573706 1101,00

380

0,69 0,83 15,2 A UCW0.83V40 G4 40x85 Not included 11509005 203,00

0,69 0,83 15,2 B UCW0.83V40 J2 53x68 Not included 11488508 237,00

0,69 0,83 15,2 B UCW0.83V40 L4 60x85 Not included 10045810 230,00

1,39 1,67 30,7 B UCW1.67V40 J4 53x85 Not included 11488510 276,00

1,39 1,67 30,7 B UCW1.67V40 L4 60x85 Not included 10045803 258,00

2,08 2,5 45,9 B UCW2.5V40 J8 53x141 Not included 11488803 325,00

2,08 2,5 45,9 B UCW2.5V40 L6 60x105 Not included 10045848 295,00

2,78 3,33 61,2 B UCW3.33V40 J8 53x141 Not included 11488809 354,00

2,78 3,33 61,2 B UCW3.33V40 L8 60x141 Not included 10045805 342,00

4,17 5 91,8 B UCW5V40 L10 60x156 Not included 10045951 431,00

5,56 6,67 122,5 B UCW6.67V40 M10 70x156 Not included 10630797 516,00

6,25 7,5 137,8 C UCW7.5V40 N14 75x205 Included 11449886 1034,00

6,94 8,33 153 C UCW8.33V40 N14 75x205 Included 11449950 1059,00

7,64 9,17 168,5 C UCW9.17V40 N14 75x205 Included 11449951 1092,00

8,33 10 183,7 C UCW10V40 N14 75x205 Included 11449887 1141,00

Notes: UCW are supplied in standard packing with 9 units each.

Page 175: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

346 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 347

Capacitors for Power Factor Correction

UCW - SINGLE PHASE CAPACITOR UNIT

Notes: UCW are supplied in standard packing with 9 units each.

VOLTAGE (V)

50 Hz 60 HzCAPACITANCE

(uF)SERIES TYPE

DIMENSIONS

ØxH (mm)DISCHARGE RESISTOR STOCK CODE

PRICE EACH

(ZAR)kVAr kVAr

400

0,83 - 16,5 A UCW0.83V44 G6 40x105 Not included 11509029 196,00

0,83 1 16,5 B UCW0.83V44 J2 53x68 Not included 11488815 220,00

0,83 1 16,5 B UCW0.83V44 L4 60x85 Not included 10072342 233,00

1,67 2 33,2 B UCW1.67V44 J6 53x105 Not included 11488820 283,00

1,67 2 33,2 B UCW1.67V44 L4 60x85 Not included 10046046 258,00

2,5 3 49,7 B UCW2.5V44 J8 53x141 Not included 11488822 346,00

2,5 3 49,7 B UCW2.5V44 L6 60x105 Not included 10046047 310,00

3,33 4 66,2 B UCW3.33V44 L8 60x141 Not included 10046048 348,00

5 - 99,5 B UCW5V44 L10 60x156 Not included 10046049 432,00

6,67 - 132,7 B UCW6.67V44 M10 70x156 Not included 10872824 518,00

7,5 9 149,2 C UCW7.5V44 N14 75x205 Included 11507590 1044,00

8,33 10 165,7 C UCW8.33V44 N14 75x205 Included 11507591 1074,00

9,17 - 182,4 C UCW9.17V44 N14 75x205 Included 11507593 1116,00

415

0,62 0,74 11,4 A UCW0.83V49 G4 40x85 Not included 11509007 195,00

0,62 0,74 11,4 B UCW0.83V49 J2 53x68 Not included 11488824 226,00

0,62 0,74 11,4 B UCW0.83V49 L4 60x85 Not included 10045811 230,00

0,74 0,89 13,6 B UCW0.83V48 L4 60x85 Not included 10072343 233,00

1,24 1,49 22,9 B UCW1.67V49 J4 53x85 Not included 11488825 270,00

1,24 1,49 22,9 B UCW1.67V49 L4 60x85 Not included 10045804 258,00

1,49 1,78 27,5 B UCW1.67V48 L4 60x85 Not included 10046050 258,00

1,85 2,22 34,3 B UCW2.5V49 J8 53x141 Not included 11488826 330,00

1,85 2,22 34,3 B UCW2.5V49 L6 60x105 Not included 10045849 295,00

2,22 2,67 41,1 B UCW2.5V48 L6 60x105 Not included 10072344 310,00

2,47 2,96 45,6 B UCW3.33V49 J8 53x141 Not included 11488827 348,00

2,47 2,96 45,6 B UCW3.33V49 L8 60x141 Not included 10045806 342,00

2,96 3,55 54,8 B UCW3.33V48 L8 60x141 Not included 10046051 348,00

3,71 4,45 68,5 B UCW5V49 L10 60x156 Not included 10186125 376,00

4,45 - 82,2 B UCW5V48 L10 60x156 Not included 10046722 432,00

4,94 5,93 91,4 B UCW6.67V49 M10 70x156 Not included 10630798 516,00

5,56 6,67 102,8 C UCW7.5V49 N14 75x205 Included 11449911 1044,00

6,18 7,41 114,1 C UCW8.33V49 N14 75x205 Included 11449952 1074,00

6,8 8,16 125,6 C UCW9.17V49 N14 75x205 Included 11449953 1116,00

7,41 8,9 137 C UCW10V49 N14 75x205 Included 11449915 1175,00

Capacitors for Power Factor Correction

UCW - SINGLE PHASE CAPACITOR

Notes: UCW are supplied in standard packing with 9 units each.

VOLTAGE (V)

50 Hz 60 HzCAPACITANCE

(uF)SERIES TYPE

DIMENSIONS

ØxH (mm)DISCHARGE RESISTOR STOCK CODE

PRICE EACH

(ZAR)kVAr kVAr

440

0,69 0,83 11,4 A UCW0.83V49 G4 40x85 Not included 11509007 195,00

0,69 0,83 11,4 B UCW0.83V49 J2 53x68 Not included 11488824 226,00

0,69 0,83 11,4 B UCW0.83V49 L4 60x85 Not included 10045811 230,00

0,83 1 13,6 B UCW0.83V48 L4 60x85 Not included 10072343 233,00

1,39 1,67 22,9 B UCW1.67V49 J4 53x85 Not included 11488825 270,00

1,39 1,67 22,9 B UCW1.67V49 L4 60x85 Not included 10045804 258,00

1,67 2 27,5 B UCW1.67V48 L4 60x85 Not included 10046050 258,00

2,08 2,5 34,3 B UCW2.5V49 J8 53x141 Not included 11488826 330,00

2,08 2,5 34,3 B UCW2.5V49 L6 60x105 Not included 10045849 295,00

2,5 3 41,1 B UCW2.5V48 L6 60x105 Not included 10072344 310,00

2,78 3,33 45,6 B UCW3.33V49 J8 53x141 Not included 11488827 348,00

2,78 3,33 45,6 B UCW3.33V49 L8 60x141 Not included 10045806 342,00

3,33 4 54,8 B UCW3.33V48 L8 60x141 Not included 10046051 348,00

4,17 5 68,5 B UCW5V49 L10 60x156 Not included 10186125 376,00

5 - 82,2 B UCW5V48 L10 60x156 Not included 10046722 432,00

5,56 6,67 91,4 B UCW6.67V49 M10 70x156 Not included 10630798 516,00

6,25 7,5 102,8 C UCW7.5V49 N14 75x205 Included 11449911 1044,00

6,94 8,33 114,1 C UCW8.33V49 N14 75x205 Included 11449952 1074,00

7,64 9,17 125,6 C UCW9.17V49 N14 75x205 Included 11449953 1116,00

8,33 10 137 C UCW10V49 N14 75x205 Included 11449915 1175,00

480

0,69 0,83 9,6 A UCW0.83V53 G4 40x85 Not included 11509028 206,00

0,69 0,83 9,6 B UCW0.83V53 J2 53x68 Not included 11488839 239,00

0,69 0,83 9,6 B UCW0.83V53 L6 60x105 Not included 10045812 241,00

0,83 1 11,5 B UCW0.83V52 L6 60x105 Not included 10072476 245,00

1,39 1,67 19,2 B UCW1.67V53 J6 53x105 Not included 11488841 288,00

1,39 1,67 19,2 B UCW1.67V53 L6 60x105 Not included 10045807 271,00

1,67 2 23,1 B UCW1.67V52 L6 60x105 Not included 10072477 271,00

2,08 2,5 28,8 B UCW2.5V53 J8 53x141 Not included 11488843 353,00

2,08 2,5 28,8 B UCW2.5V53 L6 60x105 Not included 10045850 310,00

2,5 3 34,5 B UCW2.5V52 L6 60x105 Not included 10072345 326,00

2,78 3,33 38,3 B UCW3.33V53 J8 53x141 Not included 11488845 365,00

2,78 3,33 38,3 B UCW3.33V53 L8 60x141 Not included 10045808 359,00

3,33 4 46 B UCW3.33V52 L8 60x141 Not included 10046053 366,00

4,17 5 57,6 B UCW5V53 L10 60x156 Not included 10045952 452,00

5 - 69,1 B UCW5V52 L10 60x156 Not included 10046255 453,00

5,56 6,67 76,8 B UCW6.67V53 M10 70x156 Not included 10630800 542,00

6,25 7,5 86,3 C UCW7.5V53 N14 75x205 Included 11449916 1094,00

6,94 8,33 95,9 C UCW8.33V53 N14 75x205 Included 11449954 1117,00

7,64 9,17 105,6 C UCW9.17V53 N14 75x205 Included 11449955 1129,00

8,33 10 115,1 C UCW10V53 N14 75x205 Included 11449928 1174,00

535

0,69 0,83 7,7 B UCW0.83V57 L6 60x105 Not Included 10046599 242,00

1,39 1,67 15,5 B UCW1.67V57 L6 60x105 Not Included 10046600 271,00

2,08 2,5 23,2 B UCW2.5V57 L6 60x105 Not Included 10046215 314,00

2,78 3,33 30,9 B UCW3.33V57 L6 60x105 Not Included 10046362 360,00

4,17 5 46,3 B UCW5V57 L10 60x156 Not Included 10045866 452,00

5,56 6,67 61,8 C UCW6.67V57 N14 75x205 Included 11449929 1082,00

6,25 7,5 69,5 C UCW7.5V57 N14 75x205 Included 11449930 1110,00

6,94 8,33 77,2 C UCW8.33V57 N14 75x205 Included 11449957 1113,00

7,64 9,17 85 C UCW9.17V57 N14 75x205 Included 11449959 1130,00

8,33 10 92,7 C UCW10V57 N14 75x205 Included 11449931 1190,00

Page 176: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

348 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 349

Capacitors for Power Factor Correction

UCWT - THREE-PHASE CAPACITOR UNIT

Notes: Discharge resistors already incorporated.

Supplied in single quantity with nut and washer for fixing.

VOLTAGE (V)

50 Hz 60 HzCAPACITANCE

(uF)SERIES TYPE

DIMENSIONS

ØxH (mm)STOCK CODE

PRICE EACH

(ZAR)kVAr kVAr

208

0,37 0,45 9.1x3 D UCWT0.5V25 L10 60x156 10045998 443,00

0,56 0,67 13.7x3 D UCWT0.75V25 L10 60x156 10045999 478,00

0,74 0,89 18.3x3 D UCWT1V25 L10 60x156 10046000 508,00

1,12 1,34 27.4x3 D UCWT1.5V25 L10 60x156 10046001 570,00

1,49 1,79 36.5x3 D UCWT2V25 L10 60x156 10046002 652,00

1,86 2,23 45.7x3 D UCWT2.5V25 L16 60x211 10046003 704,00

2,23 2,68 54.8x3 D UCWT3V25 L16 60x211 10046004 761,00

3,72 4,47 91.3x3 E UCWT5V25 N20 75x225 11313760 1396,00

5,59 6,7 137x3 E UCWT7.5V25 N22 75x285 11313783 1639,00

7,45 8,94 182.7x3 E UCWT10V25 N22 75x285 11313782 1897,00

7,45 8,94 182.7x3 F UCWT10V25 Q26 100x230 11914849 2087,00

9,31 11,17 228.4x3 E UCWT12.5V25 O24 85x360 10630742 2340,00

9,31 11,17 228.4x3 F UCWT12.5V25 Q26 100x230 11914851 2574,00

11,17 13,41 274x3 E UCWT15V25 O24 85x360 10630743 2465,00

11,17 13,41 274x3 F UCWT15V25 S26 116x230 11914853 2711,00

13,04 15,64 319.7x3 F UCWT17.5V25 S28 116x290 12271622 3074,00

14,9 17,88 365.4x3 F UCWT20V25 S28 116x290 12271626 3326,00

220

0,42 0,5 9.1x3 D UCWT0.5V25 L10 60x156 10045998 443,00

0,63 0,75 13.7x3 D UCWT0.75V25 L10 60x156 10045999 478,00

0,83 1 18.3x3 D UCWT1V25 L10 60x156 10046000 508,00

1,25 1,5 27.4x3 D UCWT1.5V25 L10 60x156 10046001 570,00

1,67 2 36.5x3 D UCWT2V25 L10 60x156 10046002 652,00

2,08 2,5 45.7x3 D UCWT2.5V25 L16 60x211 10046003 704,00

2,5 3 54.8x3 D UCWT3V25 L16 60x211 10046004 761,00

4,17 5 91.3x3 E UCWT5V25 N20 75x225 11313760 1396,00

6,25 7,5 137x3 E UCWT7.5V25 N22 75x285 11313783 1639,00

8,33 10 182.7x3 E UCWT10V25 N22 75x285 11313782 1897,00

8,33 10 182.7x3 F UCWT10V25 Q26 100x230 11914849 2087,00

10,42 12,5 228.4x3 E UCWT12.5V25 O24 85x360 10630742 2340,00

10,42 12,5 228.4x3 F UCWT12.5V25 Q26 100x230 11914851 2574,00

12,5 15 274x3 E UCWT15V25 O24 85x360 10630743 2465,00

12,5 15 274x3 F UCWT15V25 S26 116x230 11914853 2711,00

14,58 17,5 319.7x3 F UCWT17.5V25 S28 116x290 12271622 3074,00

16,67 20 365.4x3 F UCWT20V25 S28 116x290 12271626 3326,00

Notes: Discharge resistors already incorporated.

Supplied in single quantity with nut and washer for fixing.

Capacitors for Power Factor Correction

UCWT - THREE-PHASE CAPACITOR UNIT

VOLTAGE (V)

50 Hz 60 HzCAPACITANCE

(uF)SERIES TYPE

DIMENSIONS

ØxH (mm)STOCK CODE

PRICE EACH

(ZAR)kVAr kVAr

230

0,5 0,6 10x3 D UCWT0.5V34 L10 60x156 10862201 443,00

0,75 0,9 15x3 D UCWT0.75V34 L10 60x156 10072544 478,00

1 1,2 20.1x3 D UCWT1V34 L10 60x156 10074467 508,00

1,5 1,8 30.1x3 D UCWT1.5V34 L10 60x156 10862180 570,00

2 2,4 40.1x3 D UCWT2V34 L10 60x156 10862184 652,00

2,5 3 50.1x3 D UCWT2.5V34 L16 60x211 10072346 704,00

3 - 60.2x3 D UCWT3V34 L16 60x211 10046055 761,00

5 6 100.3x3 E UCWT5V34 N20 75x225 11871789 1396,00

7,5 9 150.4x3 E UCWT7.5V34 N22 75x285 11758922 1639,00

10 12 200.6x3 E UCWT10V34 O22 85x285 10117916 1897,00

10 12 200.6x3 F UCWT10V34 Q26 100x230 11914855 2087,00

12,5 15 250.7x3 E UCWT12.5V34 O24 85x360 12568291 2340,00

12,5 15 250.7x3 F UCWT12.5V34 Q26 100x230 11914856 2574,00

15 - 300.9x3 E UCWT15V34 O24 85x360 12568292 2465,00

15 - 300.9x3 F UCWT15V34 S26 116x230 11914888 2711,00

17,5 - 351x3 F UCWT17.5V34 S28 116x290 12271566 3074,00

20 - 401.1x3 F UCWT20V34 S28 116x290 12271567 3326,00

240

0,42 0,5 7.7x3 D UCWT0.5V29 L10 60x156 10072607 443,00

0,63 0,75 11.5x3 D UCWT0.75V29 L10 60x156 10072608 478,00

0,83 1 15.4x3 D UCWT1V29 L10 60x156 10046265 508,00

1,25 1,5 23x3 D UCWT1.5V29 L10 60x156 10072303 570,00

1,67 2 30.7x3 D UCWT2V29 L10 60x156 10046266 652,00

2,08 2,5 38.4x3 D UCWT2.5V29 L16 60x211 10748190 704,00

2,5 3 46.1x3 D UCWT3V29 L16 60x211 10748194 761,00

4,17 5 76.8x3 E UCWT5V29 N20 75x225 11983248 1396,00

6,25 7,5 115.1x3 E UCWT7.5V29 N22 75x285 11758813 1639,00

8,33 10 153.5x3 E UCWT10V29 N22 75x285 11758287 1897,00

8,33 10 153.5x3 F UCWT10V29 Q26 100x230 12029202 2087,00

10,42 12,5 191.9x3 E UCWT12.5V29 O24 85x360 11131850 2340,00

10,42 12,5 191.9x3 F UCWT12.5V29 Q26 100x230 12029203 2574,00

12,5 15 230.3x3 E UCWT15V29 O24 85x360 11131849 2465,00

12,5 15 230.3x3 F UCWT15V29 S26 116x230 12029204 2711,00

14,58 17,5 268.6x3 F UCWT17.5V29 S28 116x290 12271869 3074,00

16,67 20 307x3 F UCWT20V29 S28 116x290 12272006 3326,00

Page 177: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

350 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 351

Notes : Discharge resistors already incorporated.

Supplied in single quantity with nut and washer for fixing.

VOLTAGE (V)

50 Hz 60 HzCAPACITANCE

(uF)SERIES TYPE

DIMENSIONS

ØxH (mm)STOCK CODE

PRICE EACH

(ZAR)kVAr kVAr

380

0,42 0,5 3.1x3 D UCWT0.5V40 L10 60x156 10046005 408,00

0,63 0,75 4.6x3 D UCWT0.75V40 L10 60x156 10046006 422,00

0,83 1 6.1x3 D UCWT1V40 L10 60x156 10046007 436,00

1,25 1,5 9.2x3 D UCWT1.5V40 L10 60x156 10046008 463,00

1,67 2 12.2x3 D UCWT2V40 L10 60x156 10046009 493,00

2,08 2,5 15.3x3 D UCWT2.5V40 L10 60x156 10046010 520,00

2,5 3 18.4x3 D UCWT3V40 L10 60x156 10046011 537,00

4,17 5 30.6x3 D UCWT5V40 L16 60x211 10046012 666,00

6,25 7,5 45.9x3 E UCWT7.5V40 N20 75x225 11313784 966,00

8,33 10 61.2x3 E UCWT10V40 N20 75x225 11313787 1100,00

10,42 12,5 76.5x3 E UCWT12.5V40 N22 75x285 11313820 1227,00

12,5 15 91.8x3 E UCWT15V40 N22 75x285 11313821 1352,00

12,5 15 91.8x3 F UCWT15V40 Q26 100x230 11916878 1487,00

14,58 17,5 107.2x3 E UCWT17.5V40 O24 85x360 10630741 1658,00

14,58 17,5 107.2x3 F UCWT17.5V40 Q26 100x230 11916880 1824,00

16,67 20 122.5x3 E UCWT20V40 O24 85x360 10630745 1760,00

16,67 20 122.5x3 F UCWT20V40 Q26 100x230 11916901 1936,00

18,75 22,5 137.8x3 E UCWT22.5V40 O24 85x360 10630746 1861,00

18,75 22,5 137.8x3 F UCWT22.5V40 S26 116x230 11916903 2047,00

20,83 25 153.1x3 E UCWT25V40 O24 85x360 10630747 1963,00

20,83 25 153.1x3 F UCWT25V40 S26 116x230 11916924 2160,00

25 30 183.7x3 F UCWT30V40 S28 116x290 12272194 2884,00

29,17 35 214.3x3 F UCWT35V40 S28 116x290 12267042 3354,00

400

0,5 0,6 3.3x3 D UCWT0.5V44 L10 60x156 10046056 411,00

0,75 0,9 5x3 D UCWT0.75V44 L10 60x156 10046057 427,00

1 1,2 6.6x3 D UCWT1V44 L10 60x156 10046058 441,00

1,5 1,8 9.9x3 D UCWT1.5V44 L10 60x156 10046059 471,00

2 2,4 13.3x3 D UCWT2V44 L10 60x156 10046060 499,00

2,5 3 16.6x3 D UCWT2.5V44 L10 60x156 10046061 528,00

3 3,6 19.9x3 D UCWT3V44 L10 60x156 10046062 559,00

5 - 33.2x3 D UCWT5V44 L16 60x211 10046063 681,00

7,5 9 49.7x3 E UCWT7.5V44 N20 75x225 11313822 1253,00

10 12 66.3x3 E UCWT10V44 N20 75x225 11313824 1407,00

12,5 15 82.9x3 E UCWT12.5V44 N22 75x285 11314662 1549,00

15 - 99.5x3 E UCWT15V44 N22 75x285 11758282 1697,00

15 18 99.5x3 F UCWT15V44 Q26 100x230 11894312 1867,00

17,5 21 116.1x3 E UCWT17.5V44 O24 85x360 10995019 2082,00

17,5 - 116.1x3 F UCWT17.5V44 Q26 100x230 11916969 2290,00

20 24 132.6x3 E UCWT20V44 O24 85x360 10995021 2210,00

20 - 132.6x3 F UCWT20V44 Q26 100x230 11916999 2431,00

22,5 - 149.2x3 E UCWT22.5V44 O24 85x360 10995020 2336,00

22,5 - 149.2x3 F UCWT22.5V44 S26 116x230 11917000 2570,00

25 - 165.8x3 E UCWT25V44 O24 85x360 11005373 2465,00

25 - 165.8x3 F UCWT25V44 S26 116x230 11894313 2712,00

30 - 198.9x3 F UCWT30V44 S28 116x290 12272688 2922,00

35 - 232.1x3 F UCWT35V44 S28 116x290 12272697 3383,00

Capacitors for Power Factor Correction

UCWT - THREE-PHASE CAPACITOR UNIT

Notes: Discharge resistors already incorporated.

Supplied in single quantity with nut and washer for fixing.

Capacitors for Power Factor Correction

UCWT - THREE-PHASE CAPACITOR UNIT

VOLTAGE (V)

50 Hz 60 HzCAPACITANCE

(uF)SERIES TYPE

DIMENSIONS

ØxH (mm)STOCK CODE

PRICE EACH

(ZAR)kVAr kVAr

415

0,37 0,44 2.3x3 D UCWT0.5V49 L10 60x156 10046013 418,00

0,44 0,53 2.7x3 D UCWT0.5V48 L10 60x156 10072545 425,00

0,56 0,67 3.4x3 D UCWT0.75V49 L10 60x156 10046014 434,00

0,67 0,8 4.1x3 D UCWT0.75V48 L10 60x156 10072546 444,00

0,74 0,89 4.6x3 D UCWT1V49 L10 60x156 10046015 452,00

0,89 1,07 5.5x3 D UCWT1V48 L10 60x156 10072547 463,00

1,11 1,33 6.9x3 D UCWT1.5V49 L10 60x156 10046016 486,00

1,33 1,6 8.2x3 D UCWT1.5V48 L10 60x156 10046254 501,00

1,48 1,78 9.1x3 D UCWT2V49 L10 60x156 10046017 521,00

1,78 2,14 11x3 D UCWT2V48 L10 60x156 10072548 536,00

1,85 2,22 11.4x3 D UCWT2.5V49 L10 60x156 10046018 556,00

2,22 2,67 13.7x3 D UCWT3V49 L10 60x156 10046019 583,00

2,67 3,2 16.4x3 D UCWT3V48 L16 60x211 10072549 605,00

3,71 4,45 22.8x3 D UCWT5V49 L16 60x211 10046020 720,00

4,45 - 27.4x3 D UCWT5V48 L16 60x211 10046258 772,00

5,56 6,67 34.3x3 E UCWT7.5V49 N20 75x225 11314663 990,00

6,67 8,01 41.1x3 E UCWT7.5V48 N20 75x225 11758619 1232,00

7,41 8,9 45.7x3 E UCWT10V49 N20 75x225 11758279 1298,00

8,9 10,68 54.8x3 E UCWT10V48 N22 75x285 11758624 1330,00

9,27 11,12 57.1x3 E UCWT12.5V49 N22 75x285 11314665 1474,00

11,12 13,34 68.5x3 E UCWT12.5V48 N22 75x285 11758675 1511,00

11,12 13,34 68.5x3 E UCWT15V49 N22 75x285 11314666 1624,00

11,12 13,34 68.5x3 F UCWT15V49 Q26 100x230 11917005 1786,00

12,97 15,57 79.9x3 E UCWT17.5V49 O24 85x360 10630788 1991,00

12,97 15,57 79.9x3 F UCWT17.5V49 Q26 100x230 11917006 2190,00

13,34 16,01 82.2x3 E UCWT15V48 O22 85x285 11758677 1632,00

13,34 16,01 82.2x3 F UCWT15V48 Q26 100x230 11917040 1795,00

14,83 17,79 91.3x3 E UCWT20V49 O24 85x360 10630789 1884,00

14,83 17,79 91.3x3 F UCWT20V49 Q26 100x230 11917007 2073,00

15,57 18,68 95.9x3 F UCWT17.5V48 Q26 100x230 11917041 2201,00

16,68 20,02 102.8x3 E UCWT22.5V49 O24 85x360 10630790 1993,00

16,68 20,02 102.8x3 F UCWT22.5V49 S26 116x230 11917018 2205,00

17,79 21,35 109.6x3 E UCWT20V48 O24 85x360 11064915 2125,00

17,79 21,35 109.6x3 F UCWT20V48 S26 116x230 11917043 2337,00

18,53 22,24 114.2x3 E UCWT25V49 O24 85x360 10630791 2103,00

18,53 22,24 114.2x3 F UCWT25V49 S26 116x230 11917021 2313,00

20,02 24,02 123.3x3 F UCWT22.5V48 S26 116x230 11917045 2472,00

22,24 - 137x3 F UCWT25V48 S26 116x230 11917058 2515,00

22,24 26,69 137x3 F UCWT30V49 S28 116x290 12272719 2943,00

25,95 31,14 159.8x3 F UCWT35V49 S28 116x290 12272780 3399,00

Page 178: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

352 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 353

Notes: Discharge resistors already incorporated.

Supplied in single quantity with nut and washer for fixing.

VOLTAGE (V)

50 Hz 60 HzCAPACITANCE

(uF)SERIES TYPE

DIMENSIONS

ØxH (mm)STOCK CODE

PRICE EACH

(ZAR)kVAr kVAr

440

0,42 0,5 2.3x3 D UCWT0.5V49 L10 60x156 10046013 418,00

0,5 0,6 2.7x3 D UCWT0.5V48 L10 60x156 10072545 425,00

0,63 0,75 3.4x3 D UCWT0.75V49 L10 60x156 10046014 434,00

0,75 0,9 4.1x3 D UCWT0.75V48 L10 60x156 10072546 444,00

0,83 1 4.6x3 D UCWT1V49 L10 60x156 10046015 452,00

1 1,2 5.5x3 D UCWT1V48 L10 60x156 10072547 463,00

1,25 1,5 6.9x3 D UCWT1.5V49 L10 60x156 10046016 486,00

1,5 1,8 8.2x3 D UCWT1.5V48 L10 60x156 10046254 501,00

1,67 2 9.1x3 D UCWT2V49 L10 60x156 10046017 521,00

2 2,4 11x3 D UCWT2V48 L10 60x156 10072548 536,00

2,08 2,5 11.4x3 D UCWT2.5V49 L10 60x156 10046018 556,00

2,5 3 13.7x3 D UCWT3V49 L10 60x156 10046019 583,00

3 3,6 16.4x3 D UCWT3V48 L16 60x211 10072549 605,00

4,17 5 22.8x3 D UCWT5V49 L16 60x211 10046020 720,00

5 - 27.4x3 D UCWT5V48 L16 60x211 10046258 772,00

6,25 7,5 34.3x3 E UCWT7.5V49 N20 75x225 11314663 990,00

7,5 9 41.1x3 E UCWT7.5V48 N20 75x225 11758619 1232,00

8,33 10 45.7x3 E UCWT10V49 N20 75x225 11758279 1298,00

10 12 54.8x3 E UCWT10V48 N22 75x285 11758624 1330,00

10,42 12,5 57.1x3 E UCWT12.5V49 N22 75x285 11314665 1474,00

12,5 15 68.5x3 E UCWT12.5V48 N22 75x285 11758675 1511,00

12,5 15 68.5x3 E UCWT15V49 N22 75x285 11314666 1624,00

12,5 15 68.5x3 F UCWT15V49 Q26 100x230 11917005 1786,00

14,58 17,5 79.9x3 E UCWT17.5V49 O24 85x360 10630788 1991,00

14,58 17,5 79.9x3 F UCWT17.5V49 Q26 100x230 11917006 2190,00

15 - 82.2x3 E UCWT15V48 O22 85x285 11758677 1632,00

15 18 82.2x3 F UCWT15V48 Q26 100x230 11917040 1795,00

16,67 20 91.3x3 E UCWT20V49 O24 85x360 10630789 1884,00

16,67 20 91.3x3 F UCWT20V49 Q26 100x230 11917007 2073,00

17,5 - 95.9x3 F UCWT17.5V48 Q26 100x230 11917041 2201,00

18,75 22,5 102.8x3 E UCWT22.5V49 O24 85x360 10630790 1993,00

18,75 22,5 102.8x3 F UCWT22.5V49 S26 116x230 11917018 2205,00

20 24 109.6x3 E UCWT20V48 O24 85x360 11064915 2125,00

20 24 109.6x3 F UCWT20V48 S26 116x230 11917043 2337,00

20,83 25 114.2x3 E UCWT25V49 O24 85x360 10630791 2103,00

20,83 25 114.2x3 F UCWT25V49 S26 116x230 11917021 2313,00

22,5 - 123.3x3 F UCWT22.5V48 S26 116x230 11917045 2472,00

25 - 137x3 F UCWT25V48 S26 116x230 11917058 2515,00

25 30 137x3 F UCWT30V49 S28 116x290 12272719 2943,00

29,17 35 159.8x3 F UCWT35V49 S28 116x290 12272780 3399,00

Capacitors for Power Factor Correction

UCWT - THREE-PHASE CAPACITOR UNIT

Notes: Discharge resistors already incorporated.

Supplied in single quantity with nut and washer for fixing.

VOLTAGE (V)

50 Hz 60 HzCAPACITANCE

(uF)SERIES TYPE

DIMENSIONS

ØxH (mm)STOCK CODE

PRICE EACH

(ZAR)KVAr KVAr

480

0,42 0,5 1.9x3 D UCWT0.5V53 L10 60x156 10045990 409,00

0,5 0,6 2.3x3 D UCWT0.5V52 L10 60x156 10046259 419,00

0,63 0,75 2.9x3 D UCWT0.75V53 L10 60x156 10045991 424,00

0,75 0,9 3.5x3 D UCWT0.75V52 L10 60x156 10072550 434,00

0,83 1 3.8x3 D UCWT1V53 L10 60x156 10045992 444,00

1 1,2 4.6x3 D UCWT1V52 L10 60x156 10072551 455,00

1,25 1,5 5.8x3 D UCWT1.5V53 L10 60x156 10045993 485,00

1,5 1,8 6.9x3 D UCWT1.5V52 L10 60x156 10072552 497,00

1,67 2 7.7x3 D UCWT2V53 L10 60x156 10045994 526,00

2 2,4 9.2x3 D UCWT2V52 L10 60x156 10072553 540,00

2,08 2,5 9.6x3 D UCWT2.5V53 L10 60x156 10045995 564,00

2,5 3 11.5x3 D UCWT2.5V52 L10 60x156 10072554 578,00

3 3,6 13.8x3 D UCWT3V52 L10 60x156 10072555 610,00

4,17 5 19.2x3 D UCWT5V53 L16 60x211 10045997 751,00

5 - 23x3 D UCWT5V52 L16 60x211 10072556 769,00

6,25 7,5 28.8x3 E UCWT7.5V53 N20 75x225 11314667 1219,00

7,5 9 34.5x3 E UCWT7.5V52 N20 75x225 11758740 1249,00

8,33 10 38.4x3 E UCWT10V53 N20 75x225 11314728 1321,00

10 12 46.1x3 E UCWT10V52 N22 75x285 11758742 1353,00

10,42 12,5 48x3 E UCWT12.5V53 N22 75x285 11314729 1523,00

12,5 15 57.6x3 E UCWT12.5V52 N22 75x285 11758746 1561,00

12,5 15 57.6x3 E UCWT15V53 N22 75x285 11314730 1561,00

12,5 15 57.6x3 F UCWT15V53 Q26 100x230 11917060 1717,00

14,58 17,5 67.2x3 E UCWT17.5V53 O24 85x360 10630792 1760,00

14,58 17,5 67.2x3 F UCWT17.5V53 Q26 100x230 11917063 1936,00

15 - 69.1x3 E UCWT15V52 O22 85x285 11758808 1653,00

15 18 69.1x3 F UCWT15V52 Q26 100x230 11917094 1818,00

16,67 20 76.8x3 E UCWT20V53 O24 85x360 10630793 1864,00

16,67 20 76.8x3 F UCWT20V53 Q26 100x230 11917064 2050,00

17,5 - 80.6x3 F UCWT17.5V52 Q26 100x230 11917095 2219,00

18,75 22,5 86.3x3 E UCWT22.5V53 O24 85x360 10630794 1955,00

18,75 22,5 86.3x3 F UCWT22.5V53 S26 116x230 11917065 2151,00

20 24 92.1x3 F UCWT20V52 S26 116x230 11917097 2363,00

20,83 25 95.9x3 E UCWT25V53 O24 85x360 10630796 2063,00

20,83 25 95.9x3 F UCWT25V53 S26 116x230 11917066 2269,00

22,5 - 103.6x3 F UCWT22.5V52 S26 116x230 11917128 2490,00

25 - 115.1x3 F UCWT25V52 S26 116x230 11917129 2672,00

25 30 115.1x3 F UCWT30V53 S28 116x290 12272781 2995,00

29,17 35 134.3x3 F UCWT35V53 S28 116x290 12272784 3426,00

Capacitors for Power Factor Correction

UCWT - THREE-PHASE CAPACITOR UNIT

Page 179: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

354 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 355

Notes : Discharge resistors already incorporated.

Supplied in single quantity with nut and washer for fixing.

VOLTAGE (V)

50 Hz 60 HzCAPACITANCE

(uF)SERIES TYPE

DIMENSIONS

ØxH (mm)STOCK CODE

PRICE EACH

(ZAR)KVAr KVAr

525

5 - 19.2x3 D UCWT5VD2 L16 60x211 12634786 1075,00

10 12 38.5x3 F UCWT10VD2 Q26 100x230 12634787 1670,00

15 18 57.7x3 F UCWT15VD2 Q26 100x230 12634848 2677,00

20 - 77x3 F UCWT20VD2 S26 116x230 12634849 2949,00

25 30 96.2x3 F UCWT25VD2 S28 116x290 12634850 3295,00

30 - 115.5x3 F UCWT30VD2 S28 116x290 12634851 3769,00

535

0,42 0,5 1.5x3 D UCWT0.5V57 L10 60x156 10743966 473,00

0,63 0,75 2.3x3 D UCWT0.75V57 L10 61x156 10744000 491,00

0,83 1 3.1x3 D UCWT1V57 L10 62x156 10744001 517,00

1,25 1,5 4.6x3 D UCWT1.5V57 L10 63x156 10744036 564,00

1,67 2 6.2x3 D UCWT2V57 L10 64x156 10748191 613,00

2,08 2,5 7.7x3 D UCWT2.5V57 L10 65x156 10748192 656,00

2,5 3 9.3x3 D UCWT3V57 L10 66x156 10748195 672,00

4,17 5 15.4x3 D UCWT5V57 L16 60x211 10648884 874,00

6,25 7,5 23.2x3 E UCWT7.5V57 N20 75x225 11314731 1305,00

8,33 10 30.9x3 E UCWT10V57 N20 75x225 11314732 1387,00

10,42 12,5 38.6x3 E UCWT12.5V57 N22 75x285 11314733 1519,00

12,5 15 46.3x3 E UCWT15V57 N22 75x285 11314734 1650,00

16,67 20 61.8x3 E UCWT20V57 O24 85x360 11379918 2434,00

18,75 22,5 69.5x3 E UCWT22.5V57 O24 85x360 11512598 2519,00

20,83 25 77.2x3 E UCWT25V57 O24 85x360 11229202 2681,00

25 30 92.7x3 F UCWT30V57 S28 116x290 12273233 3295,00

29,17 35 108.1x3 F UCWT35V57 S28 116x290 12273234 3769,00

Capacitors for Power Factor Correction

UCWT - THREE-PHASE CAPACITOR UNIT

Capacitors for Power Factor Correction

MCW - THREE-PHASE MODULE CAPACITOR

VOLTAGE (V)

50 Hz 60 Hz

TYPECOMPOSITION

(Δ CONNECTION)

DIMENSIONS

(LxWxH) (mm)STOCK CODE

PRICE EACH

(ZAR)kVAr kVAr

208

1,86 2,23 MCW2.5V25 3xUCW0.83V25 L6 219x78x257 10045851 1328,00

3,72 4,47 MCW5V25 3xUCW1.67V25 L6 219x78x257 10045799 1553,00

5,59 6,7 MCW7.5V25 3xUCW2.5V25 L10 219x78x257 10186130 1713,00

7,45 8,94 MCW10V25 3xUCW3.33V25 L10 219x78x257 10046861 2001,00

220

2,08 2,5 MCW2.5V25 3xUCW0.83V25 L6 219x78x257 10045851 1328,00

4,17 5 MCW5V25 3xUCW1.67V25 L6 219x78x257 10045799 1553,00

6,25 7,5 MCW7.5V25 3xUCW2.5V25 L10 219x78x257 10186130 1713,00

8,33 10 MCW10V25 3xUCW3.33V25 L10 219x78x257 10046861 2001,00

230

2,5 3 MCW2.5V34 3xUCW0.83V34 L6 219x78x257 10072478 1329,00

5 6 MCW5V34 3xUCW1.67V34 L6 219x78x257 10211646 1577,00

7,5 9 MCW7.5V34 3xUCW2.5V34 L10 219x78x257 10211647 1765,00

10 - MCW10V34 3xUCW3.33V34 L10 219x78x257 11559337 2243,00

240

2,08 2,5 MCW2.5V29 3xUCW0.83V29 L4 219x78x257 10072559 1328,00

4,17 5 MCW5V29 3xUCW1.67V29 L6 219x78x257 10045989 1553,00

6,25 7,5 MCW7.5V29 3xUCW2.5V29 L10 219x78x257 10072302 1713,00

8,33 10 MCW10V29 3xUCW3.3V29 L10 219x78x257 11214119 2001,00

380

2,08 2,5 MCW2.5V40 3xUCW0.83V40 L4 219x78x257 10452269 1236,00

4,17 5 MCW5V40 3xUCW1.67V40 L4 219x78x257 10186090 1320,00

6,25 7,5 MCW7.5V40 3xUCW2.5V40 L6 219x78x257 10186099 1432,00

8,33 10 MCW10V40 3xUCW3.33V40 L8 219x78x257 10186092 1541,00

12,5 15 MCW15V40 3xUCW5V40 L10 219x78x257 10186131 1805,00

400

2,5 3 MCW2.5V44 3xUCW0.83V44 L4 219x78x257 10072333 1241,00

5 6 MCW5V44 3xUCW1.67V44 L4 219x78x257 10072334 1328,00

7,5 9 MCW7.5V44 3xUCW2.5V44 L6 219x78x257 10186140 1454,00

10 12 MCW10V44 3xUCW3.33V44 L8 219x78x257 10046040 1568,00

15 - MCW15V44 3xUCW5V44 L10 219x78x257 10046041 1812,00

415

1,85 2,22 MCW2.5V49 3xUCW0.83V49 L4 219x78x257 10045854 1236,00

2,22 2,67 MCW2.5V48 3xUCW0.83V48 L4 219x78x257 10072479 1241,00

3,71 4,45 MCW5V49 3xUCW1.67V49 L4 219x78x257 10186091 1320,00

4,45 5,34 MCW5V48 3xUCW1.67V48 L4 219x78x257 10072480 1328,00

5,56 6,67 MCW7.5V49 3xUCW2.5V49 L6 219x78x257 10045855 1432,00

6,67 8,01 MCW7.5V48 3xUCW2.5V48 L6 219x78x257 10072481 1454,00

7,41 8,9 MCW10V49 3xUCW3.33V49 L8 219x78x257 10186093 1541,00

8,9 10,68 MCW10V48 3xUCW3.33V48 L8 219x78x257 10072482 1568,00

11,12 13,34 MCW15V49 3xUCW5V49 L10 219x78x257 10045983 1805,00

13,34 - MCW15V48 3xUCW5V48 L10 219x78x257 11608707 1919,00

Note: Discharge resistors already incorporated.

Page 180: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

356 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 357

Note: Discharge resistors already incorporated.

VOLTAGE (V)

50 Hz 60 Hz

TYPECOMPOSITION

(Δ CONNECTION)

DIMENSIONS

(LxWxH) (mm)STOCK CODE

PRICE EACH

(ZAR)kVAr kVAr

440

2,08 2,5 MCW2.5V49 3xUCW0.83V49 L4 219x78x257 10045854 1236,00

2,5 3 MCW2.5V48 3xUCW0.83V48 L4 219x78x257 10072479 1241,00

4,17 5 MCW5V49 3xUCW1.67V49 L4 219x78x257 10186091 1320,00

5 6 MCW5V48 3xUCW1.67V48 L4 219x78x257 10072480 1328,00

6,25 7,5 MCW7.5V49 3xUCW2.5V49 L6 219x78x257 10045855 1432,00

7,5 9 MCW7.5V48 3xUCW2.5V48 L6 219x78x257 10072481 1454,00

8,33 10 MCW10V49 3xUCW3.33V49 L8 219x78x257 10186093 1541,00

10 12 MCW10V48 3xUCW3.33V48 L8 219x78x257 10072482 1568,00

12,5 15 MCW15V49 3xUCW5V49 L10 219x78x257 10045983 1805,00

15 - MCW15V48 3xUCW5V48 L10 219x78x257 11608707 1919,00

480

2,08 2,5 MCW2.5V53 3xUCW0.83V53 L6 219x78x257 10045856 1298,00

2,5 3 MCW2.5V52 3xUCW0.83V52 L6 219x78x257 10072484 1303,00

4,17 5 MCW5V53 3xUCW1.67V53 L6 219x78x257 10045857 1386,00

5 6 MCW5V52 3xUCW1.67V52 L6 219x78x257 10072485 1395,00

6,25 7,5 MCW7.5V53 3xUCW2.5V53 L6 219x78x257 10186100 1504,00

7,5 9 MCW7.5V52 3xUCW2.5V52 L6 219x78x257 10072486 1526,00

8,33 10 MCW10V53 3xUCW3.33V53 L8 219x78x257 10186101 1618,00

10 12 MCW10V52 3xUCW3.33V52 L8 219x78x257 10072487 1646,00

12,5 15 MCW15V53 3xUCW5V53 L10 219x78x257 10045984 1896,00

15 - MCW15V52 3xUCW5V52 L10 219x78x257 10072488 1903,00

535

2,08 2,5 MCW2.5V57 3xUCW0.83V57 L6 219x78x257 10073617 1302,00

4,17 5 MCW5V57 3xUCW1.67V57 L6 219x78x257 10046601 1394,00

6,25 7,5 MCW7.5V57 3xUCW2.5V57 L6 219x78x257 10046602 1513,00

8,33 10 MCW10V57 3xUCW3.33V57 L6 219x78x257 10046603 1629,00

12,5 15 MCW15V57 3xUCW5V57 L10 219x78x257 10046604 1901,00

Capacitors for Power Factor Correction

MCW - THREE-PHASE MODULE CAPACITOR

Accessories for Capacitors

DISCHARGE RESISTORS

For 2 x MCW = use 1 x BI - MCWFor 3 x MCW = use 2 x BI - MCWFor 4 x MCW = use 3 x BI - MCW

Discharge resistance

UCW (A and B series)

Reference Resistance / power

RDC 56kΩ 3W 56 kΩ / 3 W

RDC 82kΩ 3W 82 kΩ / 3 W

RDC 120kΩ 3W 120 kΩ / 3 W

RDC 150kΩ 3W 150 kΩ / 3 W

RDC 180kΩ 3W 180 kΩ / 3 W

RDC 270kΩ 3W 270 kΩ / 3 W

RDC 390kΩ 3W 390 kΩ / 3 W

RDC 560kΩ 3W 560 kΩ / 3 W

RDC 1MΩ 3W 1 MΩ / 3 W

UCW (C series)

Reference Resistance / power

RDC 28kΩ 6W 28 kΩ / 6 W

RDC 41kΩ 6W 41 kΩ / 6 W

RDC 60kΩ 6W 60 kΩ / 6 W

RDC 75kΩ 6W 75 kΩ / 6 W

RDC 135kΩ 6W 135 kΩ / 6 W

UCWT (E and F series)

Reference Resistance / power

RDC 27kΩ 5 W - UCW-T 3 x 27 kΩ / 5 W

RDC 39kΩ 3 W - UCW-T 3 x 39 kΩ / 3 W

RDC 56kΩ 3 W - UCW-T 3 x 56 kΩ / 3 W

RDC 56kΩ 5 W - UCW-T 3 x 56 kΩ / 5 W

RDC 82kΩ 5 W - UCW-T 3 x 82 kΩ / 5 W

RDC 82kΩ 3 W - UCW-T 3 x 82 kΩ / 3 W

RDC 120kΩ 3 W - UCW-T 3 x 120 kΩ / 3 W

RDC 150kΩ 3 W - UCW-T 3 x 150 kΩ / 3 W

RDC 180kΩ 3 W - UCW-T 3 x 180 kΩ / 3 W

RDC 270kΩ 3 W - UCW-T 3 x 270 kΩ / 3 W

RDC 390kΩ 3 W - UCW-T 3 x 390 kΩ / 3 W

FIXING OF CAPACITOR

MCW INTERCONNECTION

Nuts and washer for UCW and UCWT fixing

Reference Series

PAC M8 A

PAC M12 B, C, D, E and F

Bars for MCW interconnection

Reference

BI-MCW

Page 181: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

358 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 359

Accessories for Capacitors

EMPTY ENCLOSURE FOR MOUNTING CAPACITOR BANKS

EMPTY ENCLOSURE FOR MOUNTING CAPACITOR BANKS WITH PROTECTION

H

W

21

.52

0

LØ28

Ø6

12.5

Ø620

30°

30°

H

13.5

W

21.5

20

41.5

6

L12.5

Note: 1) Only for Single-Phase Capacitors UCW up to Ø60 mm (diameter).

Electrical components are not included.

Empty enclosure for capacitor bank assembly

Reference Dimensions (L x W x H) (mm)

UMW01-W41 266 x 193 x 263 (up to 9 UCW’s) 1)

UMW02-W41 390 x 193 x 263 (up to 15 UCW’s) 1)

Empty enclosure for capacitor bank assembly with protection

Reference Dimensions (L x W x H) (mm)

UWMP01-W41 357 x 261 x 484 (up to 9 UCW’s) 1)

UWMP02-W41 457 x 263 x 484 (up to 15 UCW’s) 1)

Note: 1) Only for Single-Phase Capacitors UCW up to Ø60 mm (diameter).

Accessories for Capacitors

UMW - METALLIC ENCOSURE FOR BANK OF CAPACITOR ASSEMBLY

BUS BAR FOR THREE-PHASE MODULE CAPACITOR - MCW

PAC - NUT AND WASHER FOR CAPACITOR FIXING

RDC - DISCHARGE RESISTOR FOR UCW

RDC - DISCHARGE RESISTOR FOR UCW-T

Note: Capacitor and discharge resistors are not included. Isolators are included.

Notes: 1) Upon Request.

Discharge resistor for 1/10 Un - 30 seconds.

TYPE DIMENSIONS (DXWXH) SAP CODEPRICE EACH

(ZAR)

UMW01-W41 266x265x192.5 mm (9 UCWs) 10186114 1213,00

UMW02-W41 390x265x192.5 mm (up to 15 UCWs) 10211156 1534,00

UWMP01-W41 357x258x483.5 mm (up to 9 UCWs) 10903561 3343,00

UWMP02-W41 457x260.5x483.5 mm (up to 15 UCWs) 10903704 4116,00

TYPE PACKAGING SAP CODEPRICE EACH

(ZAR)

BI MCW 3 10045985 49,00

TYPE SERIES 8.504 PT SAP CODEPRICE EACH

(ZAR)

PAC M8 A 3 10211644 5,00

PAC M12 B, C, D, E, F 3 10186132 5,00

TYPE RESISTOR SERIES PACKAGING SAP CODEPRICE EACH

(ZAR)

RDC FIXO 56kΩ 3W-UCW 56 kW/ 3 W A, B 3 10683543 19,00

RDC FIXO 82kΩ 3W-UCW 82 kW/ 3 W A, B 3 10668936 19,00

RDC FIXO 120kΩ 3W-UCW 120 kW/ 3 W A, B 3 10668937 19,00

RDC FIXO 150kΩ 3W-UCW 150 kW/ 3 W A, B 3 10668968 19,00

RDC FIXO 180kΩ 3W-UCW 180 kW/ 3 W A, B 3 10668935 19,00

RDC FIXO 270kΩ 3W-UCW 270 kW/ 3 W A, B 3 10668970 19,00

RDC FIXO 390kΩ 3W-UCW 390 kW/ 3 W A, B 3 10671279 19,00

RDC FIXO 560kΩ 3W-UCW 560 kW/ 3 W A, B 3 10668971 19,00

RDC FIXO 1MΩ 3W-UCW 1 MW / 3 W A, B 3 10668972 19,00

RDC FIXO 28kΩ 6W-UCW 28 kΩ / 6 W C 3 11456258 37,00

RDC FIXO 41kΩ 6W-UCW 41 kΩ / 6 W C 3 11456226 37,00

RDC FIXO 60kΩ 6W-UCW 60 kΩ / 6 W C 3 11456252 37,00

RDC FIXO 75kΩ 6W-UCW 75 kΩ / 6 W C 3 11456260 37,00

RDC FIXO 135kΩ 6W-UCW 135 kΩ / 6 W C 3 11456259 37,00

TYPE RESISTOR SERIES PACKAGING SAP CODEPRICE EACH

(ZAR)

RDC FIXO 39kΩ 3W-UCW-T 3x39 kΩ / 3 W E, F 3 11533460 Under request 1)

RDC FIXO 56kΩ 3W-UCW-T 3x56 kΩ / 3 W E, F 3 11533414 Under request 1)

RDC FIXO 82kΩ 3W-UCW-T 3x82 kΩ / 3 W E, F 3 11533458 Under request 1)

RDC FIXO 120kΩ 3W-UCW-T 3x120 kΩ / 3 W E, F 3 11533462 Under request 1)

RDC FIXO 150kΩ 3W-UCW-T 3x150 kΩ / 3 W E, F 3 11533468 Under request 1)

RDC FIXO 180kΩ 3W-UCW-T 3x180 kΩ / 3 W E, F 3 11533417 Under request 1)

RDC FIXO 270kΩ 3W-UCW-T 3x270 kΩ / 3 W E, F 3 11533461 Under request 1)

RDC FIXO 390kΩ 3W-UCW-T 3x390 kΩ / 3 W E, F 3 11533415 Under request 1)

RDC FIXO 27KΩ 5W - UCW-T 3x27 kΩ / 5 W E, F 3 12432701 Under request 1)

RDC FIXO 56KΩ 5W - UCW-T 3x56 kΩ / 5 W E, F 3 12436744 Under request 1)

RDC FIXO 82KΩ 5W - UCW-T 3x82 kΩ / 5 W E, F 3 12435787 Under request 1)

Page 182: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

360 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 361

Notes: 1) Maximum altitude: 2,000 m. For application in higher altitudes, please contact WEG.

2) IRAM Certification available for capacitors of the following voltage / frequency: 230 V / 50 Hz, 400 V / 50 Hz, 440 V / 50 Hz e 480 V / 50 Hz. 3) in progress to capacitors 116 x 290 mm. Capacitors in 535 V without IRAM certification.

4) in progress to capacitors 116 x 290 mm.R

US

Capacitive Units - Technical Data

Technical characteristics A series B series C series D series E series F series

Phases Single phase Three phase

Power 0.62...0.83 (kvar) 0.62...6.67 (kvar) 3.72...10 (kvar) 0.37...5 (kvar) 3.72...25 (kvar) 7.45...25 (kvar) 13.04...35 (kvar)

Rated voltage 380...535 (V) 208...535 (V)

Rated frequency 50 or 60 (Hz)

Capacitance tolerance ±5 (%)

Useful life 100,000 (h)

Temperature class

-25/D

Minimum temperature: -25 ºC

Max temperature: D

Max. temp.= 55 ºC

Avg. max. temp. in 24h = 45 ºC

Avg. max. temp. in 1 year = 35 ºC

SafetySelf-healing polypropylene film

Disconnection for overpressure

Max. short circuit capacity 10 (kA)

Protection degree IP00 IP00 IP20 IP50 IP20 IP20

Max. altitude 1) 2,000 (m)

Shield / TerminalPlastic / Double

Fast-on

Plastic / Screw

+ WasherAluminum / Box

Plastic / Screw

+ WasherAluminum / Box Aluminum / Box

Input cable connection Fast-on terminalM3x2.4 Flat/

Philips

M4x16.5 Flat/

Philips

M3x2.4 Flat/

PhilipsM4x16.5 Flat/Philips

M8 x 16.5 mm

Allen

Input cable section 0.5...6.0 (mm2) 1.5...10 (mm2) 0.5...6.0 (mm2) 1.5...10.0 (mm2) 10.0...35.0 (mm2)

Input cable torque - 0.8...1.5 (N.m) 1.5...2.5 (N.m) 0.8...1.5 (N.m) 1.5...2.5 (N.m) 4.0...6.0 (N.m)

Discharge resistance Fast-on terminalInside the

productFast-on terminal Fast-on terminal

Discharge resistor Not included Included

Capacitor fixing M8 bolt M12 bolt

Max. torque for capacitor 12 (N.m) 14 (N.m)

Impregnation Polyurethane resin

Max. voltage1.1 x Vn 8h

Duration for each 24h - not continuous (system fluctuation)

Max. dV/dt ≤30 (V/μm)

Max. current 1.3 x In (short periods of time)

Max. inrush current ≤100 x In

Voltage test between

terminals2.15 x Vn @ 2s

Voltage test between

terminals and enclosure3.6 kV @ 2s 3.6 kV @ 2s

Reference standards IEC 60831-1/2 UL 810

Certifications 2)R

US

2)R

US

R

US

2)R

US

R

US

R

US

R

US

3)4)

Note: 1) Maximum altitude: 2,000 m. For application in higher altitudes, please contact WEG.

Capacitive Module - Technical Data

Technical characteristics MCW

Phases Three phase

Power1.86...10 (kvar) for 208...240 (V)

1.85...15 (kvar) for 380...535 (V)

Rated voltage 208...535 (V)

Rated frequency 50 or 60 (Hz)

Capacitance tolerance ±5 (%)

Useful life 100,000 (h)

Temperature class

-25/D

Minimum temperature: -25 ºC

Max temperature: D

Max. temp.= 55 ºC

Avg. max. temp. in 24h = 45 ºC

Avg. max. temp. in 1 year = 35 ºC

SafetySelf-healing polypropylene film

Disconnection for overpressure

Max. short circuit capacity 10 (kA)

Protection degree IP40

Max. altitude 1) 2,000 (m)

Input cable conection LUG Terminal M8

Input cable section 1.5...35.0 (mm2)

Input cable torque 8...10 (N.m)

Discharge resistor Included

Impregnation Polyurethane resin

Max. voltage1.1 x Vn

8h duration for each 24h - not continuous (system fluctuation)

Max. dV/dt ≤30 (V/μm)

Max. current 1.3 x In (short periods of time)

Max. in-rush current ≤100 x In

Voltage test between terminals 2.15 x Vn @ 2s

Voltage test between terminals and enclosure 3 kV @ 2s

Reference standards IEC 60831-1/2 UL 810

CertificationsR

US

Page 183: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

362 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 363

CMRW - Capacitors for Motor Run

250 V - 50/60 Hz

Notes: 1) Capacitors with terminal type TD, case size is 30x56.

Article numbers for other capacitances upon request.

Also available with fixation screw M8x10. Price list + 0.15 USD.

“PAC M-8” - Set with 3 Nuts + 3 Spring washers (art. number 10211644) - Package with 100 Sets. Price per set = 0.29 USD.

Terminal type: Replace by TF200, TS or TD.

TYPE CASE SIZE PACKAGING

SAP CODEPRICE EACH

(ZAR)

WIRE

(TF200)

FAST-ON

SINGLE (TS) DOUBLE (TD) 1) WIRE FAST-ON

CMRW2D26 P0 B EXP 25x56 80 10861435 10845371 10856965 29,00 30,00

CMRW3D26 P0 B EXP 25x56 80 10861149 10845372 10857028 30,00 31,00

CMRW4D26 P0 B EXP 25x56 80 10861329 10845373 10857036 31,00 32,00

CMRW5D26 P0 B EXP 25x56 80 10798525 10845374 10857068 31,00 32,00

CMRW6D26 P0 B EXP 30x56 80 10861151 10845452 10857070 32,00 27,00

CMRW7D26 P0 B EXP 30x56 80 10861153 10845455 10856965 34,00 35,00

CMRW8D26 P0 B EXP 30x56 80 10794601 10845456 10857119 38,00 39,00

CMRW9D26 P0 B EXP 30x56 80 10861157 10845457 10857120 40,00 41,00

CMRW10D26 P0 B EXP 30x56 80 10794605 10845519 10857121 43,00 44,00

CMRW11D26 P0 B EXP 30x56 80 10861204 10845521 10857122 44,00 46,00

CMRW12D26 P0 B EXP 35x56 70 10861205 10845522 10857125 45,00 46,00

CMRW13D26 P0 B EXP 35x56 70 10861206 10845523 10857127 45,00 47,00

CMRW14D26 P0 B EXP 35x56 70 10861207 10845524 10857148 48,00 50,00

CMRW15D26 P0 B EXP 35x56 70 10861268 10845525 10857150 51,00 53,00

CMRW16D26 P0 B EXP 35x56 70 10861269 10845526 10857151 53,00 54,00

CMRW17D26 P0 B EXP 35x74 70 10861270 10845527 10857157 54,00 55,00

CMRW18D26 P0 B EXP 35x74 70 10861271 10845598 10857208 54,00 56,00

CMRW19D26 P0 B EXP 35x74 70 10861273 10845599 10857209 57,00 58,00

CMRW20D26 P0 B EXP 35x74 70 10794681 10845600 10857212 63,00 65,00

CMRW25D26 P0 B EXP 35x74 70 10794685 10806700 10857213 78,00 81,00

CMRW30D26 P0 B EXP 40x74 30 10794758 10806706 10875340 86,00 88,00

CMRW35D26 P0 B EXP 40x94 30 10794819 10857030 10791634 93,00 96,00

CMRW40D26 P0 B EXP 40x94 30 10794856 10806707 10850605 95,00 98,00

CMRW45D26 P0 B EXP 40x94 30 10861274 10803754 10792950 105,00 108,00

CMRW50D26 P0 B EXP 45x94 30 10794914 10857033 10857335 125,00 129,00

CMRW60D26 P0 B EXP 45x94 30 10861275 10857035 10857339 125,00 129,00

400 V - 50/60 Hz

TYPE CASE SIZE PACKAGING

SAP CODEPRICE EACH

(ZAR)

WIRE

(TF200)

FAST-ON

SINGLE (TS) DOUBLE (TD) 1) WIRE FAST-ON

CMRW2D34 P0 B EXP 25x56 80 10857341 10861330 10795003 26,00 27,00

CMRW3D34 P0 B EXP 25x56 80 10857344 10861331 10861332 29,00 30,00

CMRW4D34 P0 B EXP 25x56 80 10804932 10803871 10798692 30,00 31,00

CMRW5D34 P0 B EXP 30x56 80 10805193 10803836 10798694 31,00 32,00

CMRW6D34 P0 B EXP 30x56 80 10805196 10861334 10798698 32,00 33,00

CMRW7D34 P0 B EXP 30x56 80 10857361 10791698 10861335 34,00 35,00

CMRW8D34 P0 B EXP 35x56 70 10805200 10861337 10798701 36,00 37,00

CMRW9D34 P0 B EXP 35x56 70 10857364 10861378 10861379 38,00 39,00

CMRW10D34 P0 B EXP 35x56 70 10805204 10861380 10798729 38,00 39,00

CMRW11D34 P0 B EXP 35x56 70 10857366 10861437 10861742 40,00 41,00

CMRW12D34 P0 B EXP 35x56 70 10805210 10861745 10798734 41,00 42,00

CMRW13D34 P0 B EXP 35x74 70 10857379 10861747 10861770 49,00 51,00

CMRW14D34 P0 B EXP 35x74 70 10857382 10861774 10798736 52,00 53,00

CMRW15D34 P0 B EXP 35x74 70 10857384 10806752 10798739 53,00 54,00

CMRW16D34 P0 B EXP 35x74 70 10805216 10861776 10799319 55,00 57,00

CMRW17D34 P0 B EXP 35x74 70 10857402 10861779 10861781 58,00 60,00

CMRW18D34 P0 B EXP 40x74 30 10805606 10861784 10799322 64,00 66,00

CMRW19D34 P0 B EXP 40x74 30 10816084 10861786 10861787 65,00 66,00

CMRW20D34 P0 B EXP 40x74 30 10807103 10806754 10799323 66,00 68,00

CMRW25D34 P0 B EXP 40x94 30 10807106 10806816 10799324 75,00 77,00

CMRW30D34 P0 B EXP 40x94 30 10807140 10861818 10803761 86,00 89,00

CMRW35D34 P0 B EXP 45x94 30 10807147 10861820 10803795 98,00 101,00

CMRW40D34 P0 B EXP 45x94 30 10807178 10861821 10803796 105,00 108,00

CMRW45D34 P0 B EXP 45x94 30 10861849 Upon request 2) 10804725 118,00 122,00

CMRW50D34 P0 B EXP 45x94 30 10791632 10861852 10791692 128,00 131,00

CMRW60D34 P0 B EXP 60x85 20 10861858 Upon request 2) 10861861 266,00 274,00

CMRW - Capacitors for Motor Run

Notes: 1) Capacitors with terminal type TD, case size is 30x56.

Article numbers for other capacitances upon request.

Also available with fixation screw M8x10. Price list + 0.15 USD.

“PAC M-8” - Set with 3 Nuts + 3 Spring washers (art. number 10211644) - Package with 100 Sets. Price per set = 0.29 USD.

Terminal type: Replace by TF200, TS or TD.

Page 184: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

364 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 365

CMRW - Capacitors for Motor Run

440 V - 50/60 Hz

TYPE CASE SIZE PACKAGING

SAP CODEPRICE EACH

(ZAR)

WIRE

(TF200)

FAST-ON

SINGLE (TS) DOUBLE (TD) 1) WIRE FAST-ON

CMRW2D36 P0 B EXP 25x56 80 10815885 10834708 Upon request 2) 27,00 27,00

CMRW3D36 P0 B EXP 25x56 80 10815912 10834710 10835987 30,00 30,00

CMRW4D36 P0 B EXP 30x56 80 10801367 10834994 10836014 33,00 31,00

CMRW5D36 P0 B EXP 30x56 80 10861879 10835020 10836017 38,00 34,00

CMRW6D36 P0 B EXP 35x56 70 10815917 10835023 10836021 40,00 39,00

CMRW7D36 P0 B EXP 35x56 70 10815939 10835024 10836024 42,00 41,00

CMRW8D36 P0 B EXP 35x56 70 10801402 10835027 10836026 47,00 44,00

CMRW9D36 P0 B EXP 35x74 70 10861882 10835043 10836038 47,00 48,00

CMRW10D36 P0 B EXP 35x74 70 10801438 10835100 10836041 48,00 49,00

CMRW11D36 P0 B EXP 35x74 70 10815970 10835102 10836045 55,00 50,00

CMRW12D36 P0 B EXP 35x74 70 10815977 10835118 10836066 57,00 56,00

CMRW13D36 P0 B EXP 35x74 70 10815999 10835126 10836088 63,00 58,00

CMRW14D36 P0 B EXP 40x74 30 10801441 10835119 10836099 64,00 65,00

CMRW15D36 P0 B EXP 40x74 30 10816001 10835168 10836102 69,00 66,00

CMRW16D36 P0 B EXP 40x74 30 10798617 10835940 10801553 71,00 71,00

CMRW17D36 P0 B EXP 40x74 30 10816079 10835945 10836143 79,00 73,00

CMRW18D36 P0 B EXP 45x74 30 10816083 10835946 10836144 65,00 82,00

CMRW19D36 P0 B EXP 45x74 30 10816084 10835958 10836145 82,00 85,00

CMRW20D36 P0 B EXP 45x74 30 10801445 10835961 10801610 96,00 85,00

CMRW25D36 P0 B EXP 45x94 30 10801500 10835963 10836146 108,00 99,00

CMRW30D36 P0 B EXP 45x94 30 10801527 10835965 10801616 122,00 111,00

CMRW35D36 P0 B EXP 45x94 30 10801550 10835980 10801617 126,00 126,00

Notes: 1) Capacitors with terminal type TD, case size is 30x56.

Article numbers for other capacitances upon request.

Also available with fixation screw M8x10. Price list + 0.15 USD.

“PAC M-8” - Set with 3 Nuts + 3 Spring washers (art. number 10211644) - Package with 100 Sets. Price per set = 0.29 USD.

Terminal type: Replace by TF200, TS or TD.

CLAW - Capacitors for Lighting Applications

TYPE VOLTAGE (V) PACKAGING CASE SIZE SAP CODEPRICE EACH

(ZAR)

CLAW2D26 A TF200-PREXP

250

80

25x56

Under request 1) Upon request

CLAW2.9D26 A TF200-PREXP 80 Under request 1) Upon request

CLAW3D26 A TF200-PREXP 80 Under request 1) Upon request

CLAW3.6D26 A TF200-PREXP 80 Under request 1) Upon request

CLAW4D26 A TF200-PREXP 80 10766213 20,00

CLAW4.5D26 A TF200-PREXP 80 Under request 1) Upon request

CLAW5D26 A TF200-PREXP 80 Under request 1) Upon request

CLAW6D26 A TF200-PREXP 80

30x56

10766214 21,00

CLAW7D26 A TF200-PREXP 80 Under request 1) Upon request

CLAW8D26 A TF200-PREXP 80 10766215 23,00

CLAW9D26 A TF200-PREXP 80 Under request 1) Upon request

CLAW10D26 A TF200-PREXP 70

35x56

10766216 26,00

CLAW11D26 A TF200-PREXP 70 Under request 1) Upon request

CLAW12D26 A TF200-PREXP 70 Under request 1) Upon request

CLAW12.5D26 A TF200-PREXP 70 10766217 30,00

CLAW13D26 A TF200-PREXP 70 Under request 1) Upon request

CLAW14D26 A TF200-PREXP 70 Under request 1) Upon request

CLAW15D26 A TF200-PREXP 70

35x74

Under request 1) Upon request

CLAW16D26 A TF200-PREXP 70 10766230 33,00

CLAW18D26 A TF200-PREXP 70 Under request 1) Upon request

CLAW19D26 A TF200-PREXP 70 Under request 1) Upon request

CLAW20D26 A TF200-PREXP 70 10766231 39,00

CLAW25D26 A TF200-PREXP 30 40x74 10766232 41,00

CLAW30D26 A TF200-PREXP 30

40x94

Under request 1) Upon request

CLAW33D26 A TF200-PREXP 30 10766233 30,00

CLAW35D26 A TF200-PREXP 30 11040535 32,00

CLAW36D26 A TF200-PREXP 30 Under request 1) Upon request

CLAW40D26 A TF200-PREXP 30 Under request 1) Upon request

CLAW44D26 A TF200-PREXP 30

45x94

Under request 1) Upon request

CLAW45D26 A TF200-PREXP 30 10766234 34,00

CLAW50D26 A TF200-PREXP 30 10766235 38,00

CLAW60D26 A TF200-PREXP 30 11129420 45,00

Notes: Article numbers for other capacitances upon request.

Also available with fixation screw M8x10. Price list + 0.15 USD.

“PAC M-8” - Set with 3 Nuts + 3 Spring washers (art. number 10211644) - Package with 100 Sets. Price per set = 0.29 USD.

Page 185: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

366 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 367

CLAW - Capacitors for Lighting Applications

TYPE VOLTAGE (V) PACKAGING CASE SIZE SAP CODEPRICE EACH

(ZAR)

CLAW2D26 A TF200-REXP

250

80

25x56

Under request 1) #N/A

CLAW2.9D26 A TF200-REXP 80 Under request 1) #N/A

CLAW3D26 A TF200-REXP 80 Under request 1) #N/A

CLAW3.6D26 A TF200-REXP 80 Under request 1) #N/A

CLAW4D26 A TF200-REXP 80 Under request 1) #N/A

CLAW4.5D26 A TF200-REXP 80 Under request 1) #N/A

CLAW5D26 A TF200-REXP 80 Under request 1) #N/A

CLAW6D26 A TF200-REXP 80

30x56

Under request 1) #N/A

CLAW7D26 A TF200-REXP 80 Under request 1) #N/A

CLAW8D26 A TF200-REXP 80 Under request 1) #N/A

CLAW9D26 A TF200-REXP 80 Under request 1) #N/A

CLAW10D26 A TF200-REXP 70

35x56

Under request 1) #N/A

CLAW11D26 A TF200-REXP 70 Under request 1) #N/A

CLAW12D26 A TF200-REXP 70 Under request 1) #N/A

CLAW12.5D26 A TF200-REXP 70 Under request 1) #N/A

CLAW13D26 A TF200-REXP 70 Under request 1) #N/A

CLAW14D26 A TF200-REXP 70 Under request 1) #N/A

CLAW15D26 A TF200-REXP 70

35x74

Under request 1) #N/A

CLAW16D26 A TF200-REXP 70 Under request 1) #N/A

CLAW18D26 A TF200-REXP 70 Under request 1) #N/A

CLAW19D26 A TF200-REXP 70 Under request 1) #N/A

CLAW20D26 A TF200-REXP 70 Under request 1) #N/A

CLAW25D26 A TF200-REXP 30 40x74 Under request 1) #N/A

CLAW30D26 A TF200-REXP 30

40x94

Under request 1) #N/A

CLAW33D26 A TF200-REXP 30 Under request 1) #N/A

CLAW35D26 A TF200-REXP 30 Under request 1) #N/A

CLAW36D26 A TF200-REXP 30 Under request 1) #N/A

CLAW40D26 A TF200-REXP 30 Under request 1) #N/A

CLAW44D26 A TF200-REXP 30

45x94

Under request 1) #N/A

CLAW45D26 A TF200-REXP 30 Under request 1) #N/A

CLAW50D26 A TF200-REXP 30 Under request 1) #N/A

CLAW60D26 A TF200-REXP 30 Under request 1) #N/A

Notes: Article numbers for other capacitances upon request.

Also available with fixation screw M8x10. Price list + 0.15 USD.

“PAC M-8” - Set with 3 Nuts + 3 Spring washers (art. number 10211644) - Package with 100 Sets. Price per set = 0.29 USD.

TYPE VOLTAGE (V) PACKAGING CASE SIZE SAP CODEPRICE EACH

(ZAR)

CLAW2D26 A TF200-PEXP

250

80

25 x 56

Under request 1) Upon request

CLAW2.9D26 A TF200-PEXP 80 Under request 1) Upon request

CLAW3D26 A TF200-PEXP 80 Under request 1) Upon request

CLAW3.6D26 A TF200-PEXP 80 Under request 1) Upon request

CLAW4D26 A TF200-PEXP 80 10766713 20,00

CLAW4.5D26 A TF200-PEXP 80 Under request 1) Upon request

CLAW5D26 A TF200-PEXP 80 Under request 1) Upon request

CLAW6D26 A TF200-PEXP 80

30x56

10766710 21,00

CLAW7D26 A TF200-PEXP 80 Under request 1) Upon request

CLAW8D26 A TF200-PEXP 80 11040502 23,00

CLAW9D26 A TF200-PEXP 80 11040503 25,00

CLAW10D26 A TF200-PEXP 70

35x56

11040504 26,00

CLAW11D26 A TF200-PEXP 70 Under request 1) Upon request

CLAW12D26 A TF200-PEXP 70 10766577 29,00

CLAW12.5D26 A TF200-PEXP 70 10766236 30,00

CLAW13D26 A TF200-PEXP 70 Under request 1) Upon request

CLAW14D26 A TF200-PEXP 70 Under request 1) Upon request

TYPE VOLTAGE (V) PACKAGING CASE SIZE SAP CODEPRICE EACH

(ZAR)

CLAW15D26 A TF200-PEXP

250

70

35x74

Under request 1) Upon request

CLAW16D26 A TF200-PEXP 70 10766466 33,00

CLAW18D26 A TF200-PEXP 70 11040505 35,00

CLAW19D26 A TF200-PEXP 70 Under request 1) Upon request

CLAW20D26 A TF200-PEXP 70 10766237 39,00

CLAW25D26 A TF200-PEXP 30 40x74 10766575 41,00

CLAW30D26 A TF200-PEXP 30

40x94

11040500 29,00

CLAW33D26 A TF200-PEXP 30 10766258 30,00

CLAW35D26 A TF200-PEXP 30 11040506 32,00

CLAW36D26 A TF200-PEXP 30 Under request 1) Upon request

CLAW40D26 A TF200-PEXP 30 11040507 34,00

CLAW44D26 A TF200-PEXP 30

45x94

11040537 34,00

CLAW45D26 A TF200-PEXP 30 11100305 34,00

CLAW50D26 A TF200-PEXP 30 10766259 38,00

CLAW60D26 A TF200-PEXP 30 Under request 1) Upon request

CLAW - Capacitors for Lighting Applications

Notes: Article numbers for other capacitances upon request.

Also available with fixation screw M8x10. Price list + 0.15 USD.

“PAC M-8” - Set with 3 Nuts + 3 Spring washers (art. number 10211644) - Package with 100 Sets. Price per set = 0.29 USD.

Page 186: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

368 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 369

CLAW - Capacitors for Lighting Applications

TYPE VOLTAGE (V) PACKAGING CASE SIZE SAP CODEPRICE EACH

(ZAR)

CLAW2D26 A TF200EXP

250

80

25x56

10844609 10,00

CLAW2.9D26 A TF200EXP 80 25x56 10,00

CLAW3D26 A TF200EXP 80 25x56 10,00

CLAW3.6D26 A TF200EXP 80 25x56 10,00

CLAW4D26 A TF200EXP 80 25x56 10,00

CLAW4.5D26 A TF200EXP 80 25x56 10,00

CLAW5D26 A TF200EXP 80 25x56 11,00

CLAW6D26 A TF200EXP 80

30x56

10766261 12,00

CLAW7D26 A TF200EXP 80 30x56 12,00

CLAW8D26 A TF200EXP 80 30x56 13,00

CLAW9D26 A TF200EXP 80 30x56 14,00

CLAW10D26 A TF200EXP 70

35x56

10766263 14,00

CLAW11D26 A TF200EXP 70 35x56 15,00

CLAW12D26 A TF200EXP 70 35x56 15,00

CLAW12.5D26 A TF200EXP 70 35x56 16,00

CLAW13D26 A TF200EXP 70 35x56 16,00

CLAW14D26 A TF200EXP 70 35x56 16,00

CLAW15D26 A TF200EXP 70

35x74

10844715 17,00

CLAW16D26 A TF200EXP 70 35x74 19,00

CLAW18D26 A TF200EXP 70 35x74 19,00

CLAW19D26 A TF200EXP 70 35x74 20,00

CLAW20D26 A TF200EXP 70 35x74 21,00

CLAW25D26 A TF200EXP 30 40x74 10766278 26,00

CLAW30D26 A TF200EXP 30

40x94

10844729 27,00

CLAW33D26 A TF200EXP 30 40x94 29,00

CLAW35D26 A TF200EXP 30 40x94 30,00

CLAW36D26 A TF200EXP 30 40x94 31,00

CLAW40D26 A TF200EXP 30 40x94 32,00

CLAW44D26 A TF200EXP 30

45x94

10766281 32,00

CLAW45D26 A TF200EXP 30 45x94 35,00

CLAW50D26 A TF200EXP 30 45x94 42,00

CLAW60D26 A TF200EXP 30 45x94 42,00

Notes: Article numbers for other capacitances upon request.

Also available with fixation screw M8x10. Price list + 0.15 USD.

“PAC M-8” - Set with 3 Nuts + 3 Spring washers (art. number 10211644) - Package with 100 Sets. Price per set = 0.29 USD.

Terminal blocks are devices designed to provide a safe means of electrical and mechanical connection to the majority of the

electrical conductors. Among all available connectors, terminal blocks are the most commonly used due to their specific

characteristics:

Terminal Blocks

Modularity

All terminal block models are designed to side by side

assembly, ensuring the best use of space within the panels.

Easy Installation

They can be quickly and easily assembled on DIN rail reducing

panel assembly time.

Available in Two Versions

Screw and spring type connection system.

Wide Range of Accessories

Connecting bridges, identifiers, DIN rail, end plate and end

bracket.

Presentation

Connecting bridges IdentifiersScrew connection

Spring connection DIN rail End plate

End brackets

Terminal Blocks

Overview

Page 187: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

370 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 371

BTWP SERIES - TERMINAL BLOCKS WITH SCREW CONNECTION TERMINALS

Selection Guide

Notes: 1) For assembly on PF4-BTW end bracket;

BTWP 2.5

5 mm width

BTWP 4

6 mm width BTWP 6

8 mm width

Technical data Voltage / Current / Cross section Voltage / Current / Cross section Voltage / Current / Cross section

IEC 60947-7-1 750 V~ / 24 A / 2.5 mm² 750 V~ / 32 A / 4 mm² 630 V~ / 41 A / 6 mm²

UL / CSA 600 V~ / 20 A / AWG 26 ... 12 600 V~ / 30 A / AWG 26 ... 10 600 V~ / 50 A / AWG 26 ... 8

Cable stripping 10 mm 10 mm 12 mm

Tightening torque 0.4 Nm / 3.54 lb - in 0.5 Nm / 4.42 lb - in 0.8 Nm / 7.08 lb - in

Connection capacity Connection capacity Connection capacity Connection capacity

Rigid wire 0.5 ... 4 mm² 0.5 ... 6 mm² 0.5 ... 10 mm²

Flexible cable 1.5 ... 2.5 mm² 1.5 ... 4 mm² 1.5 ... 6 mm²

AWG conductor 26 ... 12 26 ... 10 26 ... 8

Reference code Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

6.6 polyamide Grey BTWP 2.5 100 BTWP 4 100 BTWP 6 100

Blue BTWP 2.5 (AZ) 100 BTWP 4 (AZ) 100 BTWP 6 (AZ) 100

Green BTWP 2.5 (VD) 100 BTWP 4 (VD) 100 BTWP 6 (VD) 100

End plate/ Sep. board Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

1.5 mm width

Grey TF-BTWP 2.5-10 100 TF-BTWP 2.5-10 100 TF-BTWP 2.5-10 100

Blue TF-BTWP 2.5-10 (AZ) 100 TF-BTWP 2.5-10 (AZ) 100 TF-BTWP 2.5-10 (AZ) 100

Green TF-BTWP 2.5-10 (VD) 100 TF-BTWP 2.5-10 (VD) 100 TF-BTWP 2.5-10 (VD) 100

Grey PD-BTWP 2.5-10 25 PD-BTWP 2.5-10 25 PD-BTWP 2.5-10 25

Separating plate Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

Grey PS1-BTWP 100 PS1-BTWP 100 PS1-BTWP 100

Connecting bridge No. of poles Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

2 PC-BTWP 2.5/2 25 PC-BTWP 4/2 25 PC-BTWP 6/2 25

3 PC-BTWP 2.5/3 20 PC-BTWP 4/3 20 PC-BTWP 6/3 20

4 PC-BTWP 2.5/4 15 PC-BTWP 4/4 15 PC-BTWP 6/4 15

10 PC-BTWP 2.5/10 5 PC-BTWP 4/10 5 PC-BTWP 6/10 5

End bracket Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

8 mm width

Grey PF3-BTW 100 PF3-BTW 100 PF3-BTW 100

Grey PF4-BTW 100 PF4-BTW 100 PF4-BTW 100

Din rail / Support Type Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

Din EN 50022

Flat MR 35x7.5 2 m busbars MR 35x7.5 2 m busbars MR 35x7.5 2 m busbars

Support ST-BTW 25 ST-BTW 25 ST-BTW 25

Group indentifier Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

Grey IG-BTW 50 IG-BTW 50 IG-BTW 50

Clear IG22-BTW 1) 25 IG22-BTW 1) 25 IG22-BTW 1) 25

Identifier Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

IDG10/5-BTW 44 IDG10/6-BTW 36 IDG10/6-BTW 36

IDB5-BTW 50 IDG10/5-BTW 44 IDG10/5-BTW 44

IDG6/5-BTW 40 IDB5-BTW 50 IDB5-BTW 50

- IDG6/5-BTW 40 IDG6/5-BTW 40

44.2

44.5

44.2

44.5

44.2

44.5

Technical data Voltage / Current / Cross section Voltage / Current / Cross section Voltage / Current / Cross section Voltage / Current / Cross section

IEC 60947-7-1 630 V~ / 57 A / 10 mm² 750 V~ / 76 A / 16 mm² 750 V~ / 125 A / 35 mm² 750 V~ / 192 A / 70 mm²

UL / CSA 600 V~ / 65 A / AWG 16 ... 6 600 V~ / 85 A / AWG 12 ... 4 600 V~ / 115 A / AWG 10 ... 2 600 V~ / 175 A / AWG 6...2/0

Cable stripping 12 mm 16 mm 18 mm 20 mm

Tightening torque 1.2 Nm / 10.62 lb - in 1.2 Nm / 10.62 lb - in 2.5 Nm / 122.12 lb - in 6 Nm / 53.10 lb - in

Connection capacity Connection capacity Connection capacity Connection capacity Connection capacity

Rigid wire 1.5 ... 16 mm² 1.5 ... 16 mm² 6 ... 16 mm² 10 ... 16 mm²

Flexible cable 1.5 ... 10 mm² 1.5 ... 16 mm² 10 ... 35 mm² 10 ... 70 mm²

AWG conductor 16 ... 6 12 ... 4 10 ... 2 6 ... 2/0

Reference code Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

6.6 polyamide Grey BTWP 10 100 BTWP 16 50 BTWP 35 50 BTWP 70 10

Blue BTWP 10 (AZ) 100 BTWP 16 (AZ) 50 BTWP 35 (AZ) 50 BTWP 70 (AZ) 10

Green BTWP 10 (VD) 100 BTWP 16 (VD) 50 BTWP 35 (VD) 50 BTWP 70 (VD) 10

End plate/ Separating board Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

1.5 mm width

Grey TF-BTWP 2.5-10 100 TF-BTWP 16 100 - -

Blue TF-BTWP 2.5-10 (AZ) 100 TF-BTWP 16 (AZ) 100 - -

Green TF-BTWP 2.5-10 (VD) 100 TF-BTWP 16 (VD) 100 - -

Grey PD-BTWP 2.5-10 25 PD-BTWP 16 25 - -

Separating board Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

Grey PS1-BTWP 100 - - -

Connecting bridgeNo. of

polesReference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

2 PC-BTWP 10/2 25 PC-BTWP 16/2 25 PC-BTWP 35/2 25 -

3 PC-BTWP 10/3 20 PC-BTWP 16/3 20 PC-BTWP 35/3 20 -

4 PC-BTWP 10/4 15 PC-BTWP 16/4 15 PC-BTWP 35/4 15 -

10 PC-BTWP 10/10 5 PC-BTWP 16/10 5 PC-BTWP 35/10 5 -

End bracket Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

8 mm width

Grey PF3-BTW 100 PF3-BTW 100 PF3-BTW 100 PF3-BTW 100

Grey PF4-BTW 100 PF4-BTW 100 PF4-BTW 100 PF4-BTW 100

Din rail / Support Type Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

Din EN 50022

Flat MR 35x7.5 2 m busbars MR 35x7.5 2 m busbars MR 35x7.5 2 m busbars MR 35x7.5 2 m busbars

Support ST-BTWw 25 ST-BTW 25 ST-BTW 25 ST-BTW 25

Group identifier Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

Grey IG-BTW 50 IG-BTW 50 IG-BTW 50 IG-BTW 50

Clear IG22-BTW 1) 25 IG22-BTW 1) 25 IG22-BTW 1) 25 IG22-BTW 1) 25

Identifier Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

IDG10/6-BTW 36 IDG10/6-BTW 36 IDG10/6-BTW 36 IDG10/6-BTW 36

IDG10/5-BTW 44 IDG10/5-BTW 44 IDG10/5-BTW 44 IDG10/5-BTW 44

IDB5-BTW 50 IDB5-BTW 50 IDB5-BTW 50 IDB5-BTW 50

IDG6/5-BTW 40 IDG6/5-BTW 40 IDG6/5-BTW 40 IDG6/5-BTW 40

BTWP SERIES - TERMINAL BLOCKS WITH SCREW CONNECTION TERMINALS

Notes: 1) For assembly on PF4-BTW and bracket;

44.2

44.5

50.0

55.5

50.0

55.5

74.0

67.5

BTWP 10

10 mm width

BTWP 16

12 mm width

BTWP 35

16 mm width

BTWP 70

22 mm width

Page 188: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

372 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 373

BTWP 95B

40 mm width

BTWP 150B

48 mm width

BTWP 240B

53 mm width

Technical data Voltage / Current /Cross section Voltage / Current / Cross section Voltage / Current / Cross section

IEC 60947-7-1 1000 V~ / 232 A / 95 mm² 1000 V~ / 309 A / 150 mm² 1000 V~ / 415 A / 240 mm²

Screw M10x30 M12x30 M16x35

Tightening torque 6 Nm / 53.10 lb - in 8 Nm / 70.80 lb - in 10 Nm / 88.50 lb - in

Reference code Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

- Grey BTWP 95B 4 BTWP 150B 4 BTWP 240B 4

Isolation cover Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

Grey TI-BTWP 95 4 TI-BTWP 150 4 TI-BTWP 240 4

Din rail / Support Type Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

DIN EN 50022

Flat MR 35x7.5 2 m busbars MR 35x7.5 2 m busbars MR 35x7.5 2 m busbars

Support ST-BTW 25 ST-BTW 25 ST-BTW 25

Group identifier Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

Grey IG-BTW 50 IG-BTW 50 IG-BTW 50

Identifier Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

IDG10/6-BTW 36 IDG10/6-BTW 36 IDG10/6-BTW 36

IDG10/5-BTW 44 IDG10/5-BTW 44 IDG10/5-BTW 44

IDB5-BTW 50 IDB5-BTW 50 IDB5-BTW 50

IDG6/5-BTW 40 IDG6/5-BTW 40 IDG6/5-BTW 40

BTWP SERIES - POWER TERMINAL BLOCKS

90.0

54.0

108

54.0

122

54.0

BTWP 2.5/4T

6 mm width

BTWP 6/10T

10 mm width

BTWP 16/35T

16 mm width

Technical data Cross section Cross section Cross section

IEC 60947-7-1 4 mm² 10 mm² 35 mm²

UL / CSA AWG 26 ... 10 AWG 16 ... 8 -

Cable stripping 10 mm 12 mm 18 mm

Tightening torque 0.5 Nm / 4.42 lb - in 1.2 Nm / 10.62 lb - in 2.5 Nm / 22.12 lb - in

Connection capacity Connection capacity Connection capacity Connection capacity

Rigid wire 0.5 ... 6 mm² 1.5 ... 16 mm² 6 ... 16 mm²

Flexible cable 1.5 ... 4 mm² 1.5 ... 10 mm² 10 ... 35 mm²

AWG conductor 26 ... 10 16 ... 8 10 ... 2

Reference code Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

6.6 polyamide Green / Yellow BTWP 2.5/4T 50 BTWP 6/10T 25 BTWP 16/35T 25

Din rail / Support Type Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

DIN EN 50022 Flat MR 35x7.5 2 m busbars MR 35x7.5 2 m busbars MR 35x7.5 2 m busbars

Support ST-BTW 25 ST-BTW 25 ST-BTW 25

Group identifier Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

Grey IG-BTW 50 IG-BTW 50 IG-BTW 50

Identifier Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

IDG10/6-BTW 36 IDG10/6-BTW 36 IDG10/6-BTW 36

IDG10/5-BTW 44 IDG10/5-BTW 44 IDG10/5-BTW 44

IDB5-BTW 50 IDB5-BTW 50 IDB5-BTW 50

IDG6/5-BTW 40 IDG6/5-BTW 40 IDG6/5-BTW 40

BTWP SERIES - GROUND TERMINAL BLOCKS

42.0

44.5

42.0

44.5

55.5

50.0

Page 189: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

374 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 375

Technical data

Voltage / Current / Cross section Voltage / Current /Cross section Voltage / Current /Cross section Voltage / Current / Cross section

IEC 60947-7-1 500 V~ / 24 A / 2.5 mm² 500 V~ / 32 A / 4 mm² 500 V~ / 32 A / 4 mm² 440 V~ / 24 A / 2.5 mm²

UL / CSA 300 V~ / 20 A / AWG 26 ... 12 300 V~ / 30 A / AWG 26 ... 10 300 V~ / 30 A / AWG 26 ... 10 300 V~ / 24 A / AWG 24 ... 12

Cable stripping 9 mm 9 mm 9 mm 9 mm

Tightening torque 0.4 Nm / 13.54 lb - in 0.5 Nm / 14.42 lb - in 0.5 Nm 0.4 Nm / 13.54 lb - in

Connection capacity Connection capacity Connection capacity Connection capacity Connection capacity

Rigid wire 0.5 ... 4 mm² 0.5 ... 6 mm² 0.5 ... 6 mm² 0.5 ... 4 mm²

Flexible cable 1.5 ... 2.5 mm² 1.5 ... 4 mm² 1.5 ... 4 mm² 1.5 ... 2.5 mm²

AWG conductor 26 ... 12 26 ... 10 26 ... 10 24 ... 12

Reference code Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

- Grey BTWD 2.5N 100 BTWD 4N 100 BTWD 4N 20 BTWT 3 25

End plate Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

1.5 mm width

Grey TF-BTWD 2.5-4N 25 TF-BTWD 2.5-4N 25 TF-BTWD 2.5-4N 25 TF-BTWT 3 10

Separating plate Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

Grey - - - PS1-BTWP 100

Connecting bridgeNo. of

polesReference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

2 PC-BTWP 2.5/2 25 PC-BTWP 4/2 25 PC-BTWP 2.5/2 25 PC-BTWT 2.5/2 25

3 PC-BTWP 2.5/3 20 PC-BTWP 4/3 20 PC-BTWP 2.5/3 20 PC-BTWT 2.5/3 20

4 PC-BTWP 2.5/4 15 PC-BTWP 4/4 15 PC-BTWP 2.5/4 15 PC-BTWT 2.5/4 15

10 PC-BTWP 2.5/10 5 PC-BTWP 4/10 5 PC-BTWP 2.5/10 5 PC-BTWT 2.5/10 5

End bracket Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

8 mm width

Grey PF3-BTW 100 PF3-BTW 100 PF3-BTW 100 PF3-BTW 100

Grey PF4-BTW 100 PF4-BTW 100 PF4-BTW 100 PF4-BTW 100

Din rail / Support Type Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

DIN EN 50022

Flat MR 35x7.5 2 m busbars MR 35x7.5 2 m busbars MR 35x7.5 2 m busbars MR 35x7.5 2 m busbars

Support ST-BTW 25 ST-BTW 25 ST-BTW 25 ST-BTW 25

Identifier group Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

Grey IG-BTW 50 IG-BTW 50 IG-BTW 50 IG-BTW 50

Clear IG22-BTW 1) 25 IG22-BTW 1) 25 IG22-BTW (1) 25 IG22-BTW 1) 25

Identifier Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

IDG10/5-BTW 44 IDG10/6-BTW 36 IDG10/6-BTW 36 IDB5-BTW 50

IDB5-BTW 50 IDG10/5-BTW 44 IDG10/5-BTW 44 -

IDG6/5-BTW 40 IDB5-BTW 50 IDB5-BTW 50 -

- IDG6/5-BTW 40 IDG6/5-BTW 40 -

BTWP / BTWT SERIES - DOUBLE TERMINAL BLOCKS AND TRIPLE TERMINAL BLOCKS

Notes: 1) For assembly on PF4-BTW end bracket;

64.0

61.3

BTWD 2.5N5 mm width

64.0

61.3

64.0

61.3

BTWD 4N6 mm width

BTWD 4NK6 mm width

65.2

87.1

5

BTWT 36 mm width

BTWP / BTWS SERIES - DOUBLE TERMINAL BLOCK + GROUND - TRIPLE TERMINAL BLOCK + GROUND -

TERMINAL BLOCK FOR DETECTORS - DISCONNECT TERMINAL

Technical data

Voltage / Current / Cross Section Voltage / Current / Cross Section Voltage / Current / Cross Section Voltage / Current / Cross Section

IEC 60947-7-1 440 V~ / 24 A / 2.5 mm² 440 V~ / 24 A / 2.5 mm² 500 V~ / 24 A / 2.5 mm² 500 V~ / 16 A / 4 mm²

UL / CSA 300 V~ / 24 A / AWG 24 ... 12 300 V~ / 24 A / AWG 24 ... 12 - 600 V~ / 16 A / AWG 26...10

Cable stripping 9 mm 9 mm 9 mm 10 mm

Tightening torque 0.4 Nm / 13.54 lb - in 0.4 Nm / 13.54 lb - in 0.4 Nm / 13.54 lb - in 0.5 Nm / 4.42 lb - in

Connection capacity Connection capacity Connection capacity Connection capacity Connection capacity

Rigid wire 0.5 ... 4 mm² 0.5 ... 4 mm² 0.5 ... 4 mm² 0.5 ... 6 mm²

Flexible cable 1.5 ... 2.5 mm² 1.5 ... 2.5 mm² 1.5 ... 2.5 mm² 1.5 ... 4 mm²

AWG conductor 24 ... 12 24 ... 12 24 ... 12 26 ... 10

Reference code Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

- Grey BTWT 2T 25 BTWT 3T 25 BTWT 3S 20 BTWS 3A 20

End plate / Separating

boardColor Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

1.5 mm width

Grey TF-BTWT 2T 10 TF-BTWT 3T 10 TF-BTWT 3S 10 TF-BTWS 3 10

Separating plate Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

Grey PS1-BTWP 100 PS1-BTWP 100 PS1-BTWP 100 -

Conneting bridgeN° of

PolesReference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

2 PC-BTWT 2.5/2 25 PC-BTWT 2.5/2 25 PC-BTWT 2.5/2 25 -

3 PC-BTWT 2.5/3 20 PC-BTWT 2.5/3 20 PC-BTWT 2.5/3 20 -

4 PC-BTWT 2.5/4 15 PC-BTWT 2.5/4 15 PC-BTWT 2.5/4 15 -

10 PC-BTWT 2.5/10 5 PC-BTWT 2.5/10 5 PC-BTWT 2.5/10 5 -

End bracket Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

8 mm width

Grey PF3-BTW 100 PF3-BTW 100 PF3-BTW 100 PF3-BTW 100

Grey PF4-BTW 100 PF4-BTW 100 PF4-BTW 100 PF4-BTW 100

Rail / Support Type Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

Din EN 50022

Flat MR 35x7.5 2 m busbars MR 35x7.5 2 m busbars MR 35x7.5 2 m busbars MR 35x7.5 2 m busbars

Support ST-BTW 25 ST-BTW 25 ST-BTW 25 ST-BTW 25

Identifier group Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

Grey IG-BTW 50 IG-BTW 50 IG-BTW 50 IG-BTW 50

Clear IG22-BTW 1) 25 IG22-BTW 1) 25 IG22-BTW 1) 25 IG22-BTW 1) 25

Identifier Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

IDB5-BTW 50 IDB5-BTW 50 IDB5-BTW 50

IDG10/6-BTW 36

IDG10/5-BTW 44

IDB5-BTW 50

IDG6/5-BTW 40

Notes: 1) For assembly on PF4-BTW end bracket;

71.7

65.2

50.5

BTWT 3S

6 mm width

BTWS 3A

6 mm width

53.5

53.0

BTWT 2T

6 mm width

65.7

BTWT 3T

6 mm width

87.5 74.3

Page 190: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

376 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 377

Technical data

Voltage / Current / Cross section Voltage / Current / Cross section Voltage / Current / Cross section Voltage / Current / Cross section

IEC 60947-7-1 500 V~ / 6.3 A / 6 mm² 750 V~ / 6.3 A / 6 mm² -V~ / 6.3 A / 6 mm² 750 V~ / 32 A / 4 mm²

UL / CSA 300 V~ / 6.3 A / AWG 26 ... 8 600 V~ / 6.3 A / AWG 22 ... 8 V~ / 6.3 A / AWG 26 ... 8 -

Fuse dimensions 5x20 ou 5x25 mm 6.35x31.75 mm (1/4"x1 1/4") 5x20 ou 5x25 mm -

Cable stripping 12 mm 12 mm 12 mm 10 mm

Tightening torque 0.8 Nm / 7.08 lb - in 0.8 Nm / 7.08 lb - in 0.8 Nm 0.5 Nm / 4.42 lb - in

Connection capacity Connection capacity Connection capacity Connection capacity Connection capacity

Rigid wire 0.5 ... 10 mm² 0.5 ... 10 mm² 0.5 ... 10 mm² 0.5 ... 6 mm²

Flexible cable 1.5 ... 6 mm² 1.5 ... 6 mm² 1.5 ... 6 mm² 1.5 ... 4 mm²

AWG conductor 26 ... 8 22 ... 8 26 ... 8 26 ... 10

Reference code Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

- Grey BTWS 2S 50

BTWS 4S 20 BTWS 2LD C03 - 24 V dc 25

BTWP 4C 50Note!

Accepts reserve fuse disconnect

lever.

BTWS 2LD D13 - 110 V ac 25

BTWS 2LD D23 - 220 V ac 25

End plate Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

1.5 mm width

Grey TF-BTWS 2 10Supplied with end plate as

standardTF-BTWS 2 10 TF-BTWP 4C 10

End bracket Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

8 mm widthGrey PF3-BTW 100 PF3-BTW 100 PF3-BTW 100 PF3-BTW 100

Grey PF4-BTW 100 PF4-BTW 100 PF4-BTW 100 PF4-BTW 100

Rail / Support Type Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

DIN EN 50022Flat MR 35x7.5 2 m busbars MR 35x7.5 2 m busbars MR 35x7.5 2 m busbars MR 35x7.5 2 m busbars

Support ST-BTW 25 ST-BTW 25 ST-BTW 25 ST-BTW 25

Group identifier Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

Grey IG-BTW 50 IG-BTW 50 IG-BTW 50 IG-BTW 50

Clear IG22-BTW 1) 25 IG22-BTW 1) 25 IG22-BTW (1) 25 IG22-BTW 1) 25

Identifier Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

IDB5-BTW 50

IDG10/6-BTW 36 IDG10/6-BTW 36 IDG10/6-BTW 36

IDG10/5-BTW 44 IDG10/5-BTW 44 IDG10/5-BTW 44

IDB5-BTW 50 IDB5-BTW 50 IDB5-BTW 50

IDG6/5-BTW 40 IDG6/5-BTW 40 IDG6/5-BTW 40

BTWS / BTWP SERIES - TERMINAL BLOCKS FOR FUSES - 1IN-2OUT TERMINAL BLOCK

Notes: 1) For assembly on PF4-BTW end bracket;

BTWS 2S

8 mm width

BTWS 4S

10 mm widthBTWP 4C

6 mm width

60.0

45.0

BTWS 2LD

10 mm width

60.0

45.0

45.0

60.0 50.5

53.3

DC AC

Technical data Voltage / Current / Cross section Voltage / Current / Cross section Voltage / Current / Cross section Voltage / Current / Cross section

IEC 60947-7-1 750 V~ / 24 A / 2.5 mm² 750 V~ / 32 A / 4 mm² 750 V~ / 41 A / 6 mm² 750 V~ / 57 A / 10 mm²

UL / CSA 600 V~ / 20 A / AWG 22 ... 12 600 V~ / 26 A / AWG 22 ... 10 600 V~ / 35 A / AWG 22 ... 8 600 V~ / 55 A / AWG 20 ... 6

Cable stripping 10 mm 12 mm 12 mm 13 mm

Connection capacity Connection capacity Connection capacity Connection capacity Connection capacity

Rigid wire 0.5 ... 4 mm² 0.5 ... 6 mm² 0.5 ... 10 mm² 0.5 ... 16 mm²

Flexible cable 0.5 ... 2.5 mm² 0.5 ... 4 mm² 0.5 ... 6 mm² 0.5 ... 10 mm²

AWG conductor 22 ... 12 22 ... 10 22 ... 8 20 ... 6

Reference code Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

6.6 polyamide

Grey BTWM 2.5 100 BTWM 4 100 BTWM 6 100 BTWM 10 100

Blue BTWM 2.5 (AZ) 100 BTWM 4 (AZ) 100 BTWM 6 (AZ) 100 BTWM 10 (AZ) 100

Green BTWM 2.5 (VD) 100 BTWM 4 (VD) 100 BTWM 6 (VD) 100 BTWM 10 (VD) 100

End plate Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

1.2 mm width Grey TF-BTWM 2.5 100 TF-BTWM 4 100 TF-BTWM 6 100 TF-BTWM 10 100

Blue TF-BTWM 2.5 (AZ) 100 TF-BTWM 4 (AZ) 100 TF-BTWM 6 (AZ) 100 TF-BTWM 10 (AZ) 100

Green TF-BTWM 2.5 (VD) 100 TF-BTWM 4 (VD) 100 TF-BTWM 6 (VD) 100 TF-BTWM 10 (VD) 100

Connecting bridgeN0. of

polesReference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

2 PC-BTWM 2.5/2 25 PC-BTWM 4/2 25 PC-BTWM 6/2 25 PC-BTWM 10/2 25

3 PC-BTWM 2.5/3 20 PC-BTWM 4/3 20 PC-BTWM 6/3 20 PC-BTWM 10/3 20

4 PC-BTWM 2.5/4 15 PC-BTWM 4/4 15 PC-BTWM 6/4 15 PC-BTWM 10/4 15

10 PC-BTWM 2.5/10 5 PC-BTWM 4/10 5 PC-BTWM 6/10 5 PC-BTWM 10/10 5

End bracket Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.. Reference code Qty/Pack.

8 mm width

Grey PF3-BTW 100 PF3-BTW 100 PF3-BTW 100 PF3-BTW 100

Grey PF4-BTW 100 PF4-BTW 100 PF4-BTW 100 PF4-BTW 100

Rail / Support Type Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

Din EN 50022

Flat MR 35x7.5 2 m busbars MR 35x7.5 2 m busbars MR 35x7.5 2 m busbars MR 35x7.5 2 m busbars

Support ST-BTW 25 ST-BTW 25 ST-BTW 25 ST-BTW 25

Group identifier Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

Grey IG-BTW 50 IG-BTW 50 IG-BTW 50 IG-BTW 50

Clear IG22-BTW 1) 25 IG22-BTW 1) 25 IG22-BTW 1) 25 IG22-BTW 1) 25

Identifier Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

IDG10/5-BTW 44 IDG10/6-BTW 36 IDG10/6-BTW 36 IDG10/6-BTW 36

IDB5-BTW 50 IDG10/5-BTW 44 IDG10/5-BTW 44 IDG10/5-BTW 44

IDG6/5-BTW 40 IDB5-BTW 50 IDB5-BTW 50 IDB5-BTW 50

- IDG6/5-BTW 40 IDG6/5-BTW 40 IDG6/5-BTW 40

BTWM SERIES - SPRING CLAMP TERMINALS

Notes: 1) For assembly on PF4-BTW end bracket;

BTWM 2.5

5 mm width

BTWM 4

6 mm width

BTWM 6

8 mm widthBTWM 10

10 mm width

51.0

35.5

64.0

38.5

70.0

43.0

37.0

55.0

Page 191: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

378 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 379

BTWM SERIES - GROUND TERMINAL BLOCKS

Technical data Cross section Cross section Cross section Cross section

IEC 60947-7-1 2.5 mm² 4 mm² 6 mm² 10 mm²

UL / CSA AWG 22 ... 12 AWG 22 ... 10 AWG 22 ... 8 AWG 20 ... 6

Cable stripping 10 mm 12 mm 12 mm 13 mm

Connection capacity Connection capacity Connection capacity Connection capacity Connection capacity

Rigid wire 0.5 ... 4 mm² 0.5 ... 6 mm² 0.5 ... 10 mm² 0.5 ... 16 mm²

Flexible cable 0.5 ... 2.5 mm² 0.5 ... 4 mm² 0.5 ... 6 mm² 0.5 ... 10 mm²

AWG condutor 22 ... 12 22 ... 10 22 ... 8 20 ... 6

Reference code Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

- Green BTWM 2.5T 50 BTWM 4T 50 BTWM 6T 40 BTWM 10T 30

End plate Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

1.2 mm width

Green TF-BTWM 2.5 (VD) 10 TF-BTWM 4 (VD) 10 TF-BTWM 6 (VD) 10 TF-BTWM 10 (VD) 10

End bracket Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

8 mm width

Grey PF3-BTW 100 PF3-BTW 100 PF3-BTW 100 PF3-BTW 100

Grey PF4-BTW 100 PF4-BTW 100 PF4-BTW 100 PF4-BTW 100

Din Rail / Support Type Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

DIN EN 50022

Flat MR 35x7.5 2 m busbars MR 35x7.5 2 m busbars MR 35x7.5 2 m busbars MR 35x7.5 2 m busbars

Support ST-BTW 25 ST-BTW 25 ST-BTW 25 ST-BTW 25

Group identifier Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

Grey IG-BTW 50 IG-BTW 50 IG-BTW 50 IG-BTW 50

Clear IG22-BTW 1) 25 IG22-BTW 1) 25 IG22-BTW 1) 25 IG22-BTW 1) 25

Identifier Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

IDG10/5-BTW 44 IDG10/6-BTW 36 IDG10/6-BTW 36 IDG10/6-BTW 36

IDB5-BTW 50 IDG10/5-BTW 44 IDG10/5-BTW 44 IDG10/5-BTW 44

IDG6/5-BTW 40 IDB5-BTW 50 IDB5-BTW 50 IDB5-BTW 50

- IDG6/5-BTW 40 IDG6/5-BTW 40 IDG6/5-BTW 40

Notes: 1) For assembly on PF4-BTW end bracket;

BTWM 2.5T

5 mm width

BTWM 4T

6 mm width

BTWM 6T

8 mm width

BTWM 10T

10 mm width

51.0

35.5

55.0

37.0

64.0

38.5

70.0

43.0

Technical data

Voltage / Current /Cross section Voltage / Current / Cross section Voltage / Current / Cross section Voltage / Current / Cross section

IEC 60947-7-1 500 V~ / 24 A / 2.5 mm² 750 V~ / 30 A / 4 mm² 750 V~ / 30 A / 4 mm² 500 V~ / 24 A / 2.5 mm²

UL / CSA 600 V~ / 20 A / AWG 22 ... 12 600 V~ / 26 A / AWG 22 ... 10 600 V~ / 26 A / AWG 22 ... 12 600 V~ / 20 A / AWG 22 ... 12

Cable stripping 10 mm 12 mm 10 mm 10 mm

Connection capacity Connection capacity Connection capacity Connection capacity Connection capacity

Rigid wire 0.5 ... 4 mm² 0.5 ... 6 mm² 0,5 ... 6 mm² 0.5 ... 4 mm²

Flexible cable 0.5 ... 2.5 mm² 0.5 ... 4 mm² 0.5 ... 4 mm² 0.5 ... 2.5 mm²

AWG conductor 22 ... 12 22 ... 10 22 ... 10 22 ... 12

Reference code Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

6.6 polyamide Grey BTWM 2.5-2F 50 BTWM 4-2F 50 BTWM 4-2K 50 BTWM 2.5-3F 20

End plate Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

1.5 mm width

Grey TF-BTWM 2.5-2F 50 TF-BTWM 4-2F 25 TF-BTWM 4-2F 50 TF-BTWM 2.5-3F 10

Connecting bridgeN0. of

polesReference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack Reference code Qty/Pack.

2 PC-BTWM 2.5/2 25 PC-BTWM 4/2 25 PC-BTWM 4/2 25 PC-BTWM 2.5/2 25

3 PC-BTWM 2.5/3 20 PC-BTWM 4/3 20 PC-BTWM 4/3 20 PC-BTWM 2.5/3 20

4 PC-BTWM 2.5/4 15 PC-BTWM 4/4 15 PC-BTWM 4/4 15 PC-BTWM 2.5/4 15

10 PC-BTWM 2.5/10 5 PC-BTWM 4/10 5 PC-BTWM 4/10 5 PC-BTWM 2.5/10 5

End bracket Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

8 mm width

Grey PF3-BTW 100 PF3-BTW 100 PF3-BTW 100 PF3-BTW 100

Grey PF4-BTW 100 PF4-BTW 100 PF4-BTW 100 PF4-BTW 100

Rail / Support Type Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

Din EN 50022

Flat MR 35x7.5 2 m busbars MR 35x7.5 2 m busbars MR 35x7,5 2 m busbars MR 35x7.5 2 m busbars

Support ST-BTW 25 ST-BTW 25 ST-BTW 25 ST-BTW 25

Identifier group Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

Grey IG-BTW 50 IG-BTW 50 IG-BTW 50 IG-BTW 50

Clear IG22-BTW 1) 25 IG22-BTW 1) 25 IG22-BTW (1) 25 IG22-BTW 1) 25

Identifier Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

IDB5-BTW 50

IDG10/6-BTW 36 IDG10/6-BTW 36

IDB5-BTW 50IDG10/5-BTW 44 IDG10/5-BTW 44

IDB5-BTW 50 IDB5-BTW 50

IDG6/5-BTW 40 IDG6/5-BTW 40

BTWM SERIES - DOUBLE TERMINAL BLOCKS - TRIPLE TERMINAL BLOCKS

Notes: 1) For assembly on PF4-BTW end bracket;

BTWM 2.5-2F

5 mm width

BTWM 4-2F

6 mm width

90.3

55.5

BTWM 4-2FK6 mm width

BTWM 2.5-3F

5 mm width

83.7

64.8

90.3

55.5

100.0

75.0

Page 192: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

380 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 381

Technical data

Voltage / Current / Cross section Voltage / Current / Cross section Voltage / Current / Cross section

IEC 60947-7-1 500 V~ / 24 A / 2.5 mm² 500 V~ / 24 A / 2.5 mm² 500 V~ / 24 A / 2.5 mm²

UL / CSA 600 V~ / 20 A / AWG 22 ... 12 600 V~ / 20 A / AWG 22 ... 12 -

Cable stripping 10 mm 10 mm 10 mm

Connection capacity Connection capacity Connection capacity Connection capacity

Rigid wire 0.5 ... 4 mm² 0.5 ... 4 mm² 0.5 ... 4 mm²

Flexible cable 0.5 ... 2.5 mm² 0.5 ... 2.5 mm² 0.5 ... 2.5 mm²

AWG conductor 22 ... 12 22 ... 12 22 ... 12

Reference code Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

- Grey BTWM 2.5-2FT 20 BTWM 2.5-3FT 20 BTWM 3S 20

End plate Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

1.5 mm width

Grey TF-BTWM 2.5-2FT 10 TF-BTWM 2.5-3FT 10 TF-BTWM 3S 10

Connecting bridgeN0. of

polesReference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

2 PC-BTWM 2.5/2 25 - PC-BTWM 2.5/2 25

3 PC-BTWM 2.5/3 20 - PC-BTWM 2.5/3 20

4 PC-BTWM 2.5/4 15 - PC-BTWM 2.5/4 15

10 PC-BTWM 2.5/10 5 - PC-BTWM 2.5/10 5

End bracket Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

8 mm width Grey PF3-BTW 100 PF3-BTW 100 PF3-BTW 100

Grey PF4-BTW 100 PF4-BTW 100 PF4-BTW 100

Din rail / Support Type Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

DIN EN 50022

Flat MR 35x7.5 2 m busbars MR 35x7.5 2 m busbars MR 35x7.5 2 m busbars

Support ST-BTW 25 ST-BTW 25 ST-BTW 25

Group identifier Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

Grey IG-BTW 50 IG-BTW 50 IG-BTW 50

Clear IG22-BTW 1) 25 IG22-BTW 1) 25 IG22-BTW 1) 25

Identifier Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

IDB5-BTW 50 IDB5-BTW 50 IDB5-BTW 50

BTWM SERIES - DOUBLE TERMINAL BLOCK + GROUND - TRIPLE TERMINAL BLOCK + GROUND

- TERMINAL BLOCK FOR DETECTORS

Notes: 1) For assembly on PF4-BTW end bracket;

BTWM 2.5-2FT

5 mm widthBTWM 2.5-3FT

5 mm width

BTWM 3S

5 mm width

83.7

64.8

100.0

74.5

76.1

75.0

Technical data Voltage / Current / Cross section Voltage / Current / Cross section Voltage / Current / Cross section Voltage / Current /Cross section

IEC 60947-7-1 750 V~ / 16 A / 2.5 mm² 500 V~ / 10 A / 4 mm² 750 V~ / 30 A / 4 mm² 500 V~ / 10 A / 4 mm²

UL / CSA 600 V~ / 10 A / AWG 22 ... 12 600 V~ / 10 A / AWG 22 ... 10 600 V~ / 26 A / AWG 22 ... 12 600 V~ / 10 A / AWG 22 ... 10

Fuse dimensions - 5x20 or 5x25 mm 5x20 or 5x25 mm 6.35x31.75 mm (1/4"x1 1/4")

Cable stripping 10 mm 12 mm 10 mm 12 mm

Connection capacity Connection capacity Connection capacity Connection capacity Connection capacity

Rigid wire 0.5 ... 4 mm² 0.5 ... 6 mm² 0.5 ... 6 mm² 0.5 ... 6 mm²

Flexible cable 0.5 ... 2.5 mm² 0.5 ... 4 mm² 0.5 ... 4 mm² 0.5 ... 4 mm²

AWG conductor 22 ... 12 22 ... 10 22 ... 10 22 ... 10

Reference code Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

-

Grey BTWM 2.5A 50 BTWM S 20 BTWM S 20 BTWM I 20

- -

Note!

Reserve fuse housed in disconnect

lever.

BTWM SLD C03 - 24 V dc

BTWM SLD D13 - 110 V ac

BTWM SLD D23 - 220 V ac

Note!

Reserve fuse housed in

disconnect lever.

End plate Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

1.5 mm width

Grey TF-BTWM 2.5A 10 TF-BTWM S-I 10 TF-BTWM S-I 50 TF-BTWM S-I 10

Connecting bridgeN0. of

PolesReference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

2 PC-BTWM 2.5/2 25 PC-BTWM 6/2 25 PC-BTWM 4/2 25 PC-BTWM 6/2 25

3 PC-BTWM 2.5/3 20 PC-BTWM 6/3 20 PC-BTWM 4/3 20 PC-BTWM 6/3 20

4 PC-BTWM 2.5/4 15 PC-BTWM 6/4 15 PC-BTWM 4/4 15 PC-BTWM 6/4 15

10 PC-BTWM 2.5/10 5 PC-BTWM 6/10 5 PC-BTWM 4/10 5 PC-BTWM 6/10 5

End bracket Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

8 mm width

Grey PF3-BTW 100 PF3-BTW 100 PF3-BTW 100 PF3-BTW 100

Grey PF4-BTW 100 PF4-BTW 100 PF4-BTW 100 PF4-BTW 100

Din rail / Suppot Type Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

DIN EN 50022

Flat MR 35x7.5 2 m busbars MR 35x7.5 2 m busbars MR 35x7,5 2 m busbars MR 35x7.5 2 m busbars

Support ST-BTW 25 ST-BTW 25 ST-BTW 25 ST-BTW 25

Group identifier Color Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

Grey IG-BTW 50 IG-BTW 50 IG-BTW 50 IG-BTW 50

Clear IG22-BTW 1) 25 IG22-BTW 1) 25 IG22-BTW (1) 25 IG22-BTW 1) 25

Identifier Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

IDG10/5-BTW 44 IDB5-BTW 50 IDG10/6-BTW 36 IDB5-BTW 50

IDB5-BTW 50 - IDG10/5-BTW 44 -

IDG6/5-BTW 40 - IDB5-BTW 50 -

- - IDG6/5-BTW 40 -

BTWM SERIES - DISCONNECT TERMINAL - TERMINAL BLOCKS FOR FUSES

Notes: 1) For assembly on PF4-BTW end bracket;

67.0

64.5

67.0

64.5

67.0

64.5

BTWM 2.5A

5 mm width

BTWM S

8 mm widthBTWM SLD8 mm width

BTWM I

8 mm width

69,1

37.5

69.1

Page 193: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

382 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 383

CB Series

Busbar connectors

CB4 CB10 CB35

Technical data Technical data Technical data Technical data

Cross section 4 mm² 10 mm² 35 mm²

Screw M3 M4 M6

Busbar dimensions 10 x 3 mm 10 x 3 mm 10 x 3 mm

Cable stripping 16 mm 19 mm 19 mm

Tightening torque 0.5 Nm / 4.42 lb - in 1.2 Nm / 10.62 lb - in 2.8 Nm / 24.78 lb - in

Connection capacity Connection capacity Connection capacity Connection capacity

Rigid wire 0.5 ... 6 mm² 1.5 ... 10 mm² 16 ... 50 mm²

Flexible cable 0.5 ... 4 mm² 2.5 ... 10 mm² 16 ... 35 mm²

Reference code Color Reference code Qty/Pack Reference code Qty/Pack Reference code Qty/Pack

Notes: 1) Also fits busbars of 15x2 mm, 15x3 mm, 12x2 mm and 6x6 mm;

2) Pictures for illustration purposes only.

-

- CB4-BTW 200 CB10-BTW 100 CB35-BTW 50

Blue CB4N-BTW 100 CB10N-BTW 100 CB35N-BTW 50

Green/Yellow CB4PE-BTW 100 CB10PE-BTW 100 CB35PE-BTW 50

Busbar support Color Reference code Qty/Pack Reference code Qty/Pack Reference code Qty/Pack

Beige SB-BTW 1) 50 SB-BTW 1) 50 SB-BTW 1) 50

Copper busbar 10 x 3 mm Reference code Qty/Pack Reference code Qty/Pack Reference code Qty/Pack

Tin plated BR10x3 1 m width BR10x3 1 m width BR10x3 1 m width

Identifier Reference code Qty/Pack. Reference code Qty/Pack. Reference code Qty/Pack.

IDB5-BTW 50 IDB5-BTW 50 IDB5-BTW 50

PWA3 and PWA4 Printing System

PWA3 and PWA4 are the most flexible identification plotters for industrial applications, allowing to record all

identification material like terminal blocks identifiers, self-adhesive plates and cable identifier plates with the use of

only one plotter.

The control is made by software in a clear and quick way and the plotter is connected to a computer via USB

connection. The operation is possible with only a few clicks, making recording a simple operation.

INCLUDED ITEMS ON PWA3 PLOTTER Two support trays for terminal block identifier IDG-BTW /

IDB5-BTW Two 0.25 mm plotter pens C025-PW Five replacement inks for plotter pen (5 x 1 ml) CT-PW One permanent 0.30 mm pen (test) CP030-PW One 30 ml replacement ink RT-PW One cleaning kit KL-PW One protection plotter cover CP-PW One plate set for pen cleaning with 25 pieces

INCLUDED ITEMS ON PWA4 PLOTTER Two support trays for terminal block identifier IDG-BTW /

IDB5-BTW Two 0.25 mm plotter pens C025-PW One plate set for pen cleaning with 25 pieces

ACCESSORIES FOR PLOTTING SYSTEM

WEG has a complete series of replacements for PWA3 and PWA4 plotting systems.

30 ml plotter ink replacement - RT-PW 5 x 1 ml plotter ink replacement - CT-PW 0.18 mm rechargeable plotter pen - C018-PW 0.25 mm rechargeable plotter pen - C025-PW 0.35 mm rechargeable plotter pen - C035-PW 0.50 mm rechargeable plotter pen - C050-PW 0.70 mm rechargeable plotter pen - C070-PW 1.00 mm rechargeable plotter pen - C100-PW 0.18 mm disposable plotter pen - C018-PD 0.25 mm disposable plotter pen - C025-PD 0.35 mm disposable plotter pen - C035-PD 0.50 mm disposable plotter pen - C050-PD 0.70 mm disposable plotter pen - C070-PD 1.00 mm disposable plotter pen - C100-PD 0.30 mm permanent mm pen (test) - CP030-PW Cleaning kit - KL-PW Plotting tray for IDB5 identifiers - IDB5-PW Plotting tray for IDG identifiers - IDG-PW Plotting tray for plates - KLM-PW

Page 194: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

384 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 385

KIP/KBEP IDENTIFIER SETS FOR CONDUCTORS

The clear identification of cables and conductors contributes much for a better visualization and maintenance in panels and

instalations. The identification of conductors is permanent and of high quality.

We supply the following items for the identification of conductors, each set contains 20 identifiers:

KIP 15W

KIP 23W

KIP 30W

KBEP 209W

15 x 4 mm identification set for conductors - KIP 15W

23 x 4 mm identification set for conductors - KIP 23W

30 x 4 mm identification set for conductors - KIP 30W

20 x 9 mm identification set for conductors - KBEP 209W

KKS/KBEP TRANSPARENT COVERS FOR CABLE IDENTIFIERS

These cable identification systems are composed by covers and

identification plates. The KKS covers are available from 1.5 up

to 25 mm diameter.

For larger cables use KBE-3 covers fixed with cable ties.

Available references

Cover reference Cable diameter Identification set Identification size Standard package (PCS)

KKS 15/1.5-2.5 1.5-2.5 mm2 KIP 15W

15x4 mm 500KKS 15/2.5-4 2.5-4 mm2 KIP 15W

KKS 15/6-10 6-10 mm2 KIP 15W

KKS 15/16-25 16-25 mm2 KIP 15W

KKS 23/1.5-2.5 1.5-2.5 mm2 KIP 23W

23x4 mm 500KKS 23/2.5-4 2.5-4 mm2 KIP 23W

KKS 23/6-10 6-10 mm2 KIP 23W

KKS 23/16-25 16-25 mm2 KIP 23W

KKS 30/1.5-2.5 1.5-2.5 mm2 KIP 30W

30x4 mm 500KKS 30/2.5-4 2.5-4 mm2 KIP 30W

KKS 30/6-10 6-10 mm2 KIP 30W

KKS 30/16-25 16-25 mm2 KIP 30W

KBE-3 > 25 mm2 KBEP 209 W 20x9 mm 500

Page 195: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

386 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 387

Self-adhesive plates kit with 80 plates of

45x14 mm. KLM 45X14

Self-adhesive plates kit with 80 plates of

27x18 mm. KLM 27X18

Self-adhesive plates kit with 20 plates of

70x35 mm. KLM 70X35

Self-adhesive plates kit with 10 plates of

120x35 mm. KLM 120X35

Self-adhesive plates kit with 120 plates of

27x12.5 mm. KLM 27X12.5

KLM SELF-ADHESIVE PLATES

The identification of electric components and

control panels is a requirement for a fast and

objective work. WEG offers excellent self-adhesive

plates in several sizes. This type of identification is

economical and has the characteristic of being very

resistant. Nowadays WEG provides five distinct

sizes of self-adhesive plates, according to the

information below:

KLM 27X12.5

KLM 45X14

KLM 27X18

KLM 70X30

KLM 120X35

Terminal Blocks

SCREW TYPE TERMINAL BLOCKS - BTWP

TERMINAL

BLOCKDESCRIPTION CROSS - SECTION (mm2)

PACKAGING

(UN)TYPE SAP CODE

PRICE EACH

(ZAR)

Standard type

Terminal 2.5 mm² 2,5 100 BTWM 2.5-CZ 750 V 10289013 10,00

Terminal 2.5 mm² (blue) 2,5 100 BTWM 2.5-AZ 750 V 10289583 10,00

Terminal 2.5 mm² (green) 2,5 100 BTWM 2.5-VD 750 V 10289584 10,00

Terminal 2.5 mm² (red) 2,5 100 BTWM 2.5-VM 750 V 11458186 15,00

Terminal 4 mm² 4 100 BTWM 4-Cz 750 V 10289014 15,00

Terminal 4 mm² (blue) 4 100 BTWM 4-Az 750 V 10289585 15,00

Terminal 4 mm² (green) 4 100 BTWM 4-VD 750 V 10289586 15,00

Terminal 4 mm² (red) 4 100 BTWM 4-VM 750 V 11458187 22,00

Terminal 6 mm² 6 100 BTWM 6-Cz 750 V 10289015 22,00

Terminal 6 mm² (blue) 6 100 BTWM 6-AZ 750 V 10289587 22,00

Terminal 6 mm² (green) 6 100 BTWM 6-VD 750 V 10289588 22,00

Terminal 6 mm² (red) 6 100 BTWM 6-VM 750 V 11458198 31,00

Terminal 10 mm² 10 100 BTWM 10-CZ 750 V 10289016 31,00

Terminal 10 mm² (blue) 10 100 BTWM 10-Az 750 V 10289589 31,00

Terminal 10 mm² (green) 10 100 BTWM 10-VD 750 V 10289590 31,00

Terminal 10 mm² (red) 10 100 BTWM 10-VM 750 V 11458199 31,00

Terminal 16 mm² 16 50 BTWP 16-Cz 750 V 10261738 28,00

Terminal 16 mm² (bluel) 16 50 BTWP 16-Az 750 V 10289152 28,00

Terminal 16 mm² (green) 16 50 BTWP 16-VD 750 V 10289461 28,00

Terminal 16 mm² (red) 16 50 BTWP 16-VM 750 V 11458181 54,00

Terminal 35 mm² 35 50 BTWP 35-Cz 750 V 10261739 54,00

Terminal 35 mm² (blue) 35 50 BTWP 35-Az 750 V 10289462 54,00

Terminal 35 mm² (green) 35 50 BTWP 35-VD 750 V 10289463 54,00

Terminal 35 mm² (red) 35 50 BTWP 35-VM 750 V 11458182 131,00

Terminal 70 mm² 70 10 BTWP 70-Cz 750 V 10261740 131,00

Terminal 70 mm² (blue) 70 10 BTWP 70-AZ 750 V 10289464 131,00

Terminal 70 mm² (green) 70 10 BTWP 70-VD 750 V 10289465 131,00

Terminal 70 mm² (red) 70 10 BTWP 70-VM 750 V 11458184 296,00

High current

type

Terminal 95 mm² 95 4 BTWP 95B-Cz 1000 V 10261741 374,00

Terminal 150 mm² 150 4 BTWP 150B-CZ 1000 V 10261742 519,00

Terminal 240 mm² 240 4 BTWP 240B-CZ 1000 V 10261743 40,00

Earth type

Earth terminal 2.5/4 mm² 4 50 BTWP 2.5/4T-Vd/Am 10261744 47,00

Earth terminal 6/10 mm² 10 25 BTWP 6/10T-Vd/Am 10261745 47,00

Earth terminal 16 mm² 16 50 BTWP 16T-Vd/Am 11716372 86,00

Earth terminal 35 mm² 35 40 BTWP 35T-Vd/Am 11716376 24,00

Double type

Double terminal 2.5 mm² 2,5 100 BTWD 2.5N-Cz 500 V 10261747 28,00

Double terminal 4 mm² 4 100 BTWD 4N-Cz 500 V 10261748 28,00

Double terminal 4 mm² w/ jumper 4 20 BTWD 4NK 11031838 51,00

Triple type

Triple terminal 2.5 mm_ 2,5 25 BTWT 3-Cz D36 10261749 60,00

Terminal 2P+T 2.5 mm_ 2,5 25 BTWT 2T-Cz D36 10261750 84,00

Terminal 3P+T 2.5 mm_ 2,5 25 BTWT 3T-Cz D36 10261751 #N/A

Sensor type Sensor terminal 2.5 mm² 2.5 20 BTWT 3S-Cz 500 V 10261752 #N/A

Disconnect

terminalDisconnect terminal 4 mm² 4 20 BTWS 3A-CZ 500 V 10261753

#N/A

55,00

Fuse terminalFuse terminal 6 mm² 6 50 BTWS 2S-Cz 500 V 10261754

55,00

65,00

Fuse terminal 6 mm² 6 20 BTWS 4S-CZ 750 V 10261760 65,00

Fuse terminal

w/ LED

Fuse terminal 6 mm² w/ 24 V dc/cc LED 6 25 BTWS 2LD-CZ C03 10261755 #N/A

Fuse terminal 6 mm² w/ 110 V ac/ca LED 6 25 BTWS 2LD-CZ D13 10847567#N/A

#N/A

Fuse terminal 6 mm² w/ 220 V ac/ca LED 6 25 BTWS 2LD-Cz D23 10847581 #N/A

Special type Terminal 1IN 2OUT 4 mm_ 4 50 BTWP 4C-CZ 750 V 10261762 #N/A

Page 196: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

388 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 389

Terminal Blocks

ACCESSORIES FOR SCREW TYPE TERMINAL BLOCKS

ACCESSORIES DESCRIPTION PACKAGING TYPESTOCK

CODE

PRICE EACH

(ZAR)

End plate

End plate 100 TF-BTWP 2.5-10 C 10261763 5,00

End plate blue 100 TF-BTWP 2.5-10 (AZ) 10289466 5,00

End plate green 100 TF-BTWP 2.5-10 (VD) 10289467 5,00

End plate red 100 TF-BTWP 2.5-10 R 11461173 5,00

End plate yellow 100 TF-BTWP 2.5-10 Y 11742898 5,00

End plate 100 TF-BTWP 16 C 10261764 7,00

End plate blue 100 TF-BTWP 16 (AZ) 10289468 7,00

End plate green 100 TF-BTWP 16 (VD) 10261777 7,00

End plate red 100 TF-BTWP 16 R 11461174 7,00

End plate 25 TF-BTWD 2.5-4N C 10261765 8,00

End plate 10 TF-BTWT 3 C 10261766 8,00

End plate 10 TF-BTWT 2T C 10261767 7,00

End plate 10 TF-BTWT 3T C 10261768 9,00

End plate 10 TF-BTWT 3S C 10261769 8,00

End plate 10 TF-BTWS 3 C 10261770 6,00

End plate 10 TF-BTWS 2 C 10261771 8,00

End plate 10 TF-BTWP 4C C 10261772 7,00

Insulation

cover

Insulation cover 4 TI-BTWP 95 C 10261775 70,00

Insulation cover 4 TI-BTWP 150 C 10261776 82,00

Insulation cover 4 TI-BTWP 240 C 10288979 121,00

PartitionPartition 25 PD-BTWP 2.5-10 C 10261773 6,00

Partition 25 PD-BTWP 16 C 10261774 8,00

Small partition Small partition 100 PS1-BTWP C 10288980 9,00

Cross-

connection

Cross-connection 2.5 mm² (2P) 25 PC-BTWP 2.5/2 10288981 13,00

Cross-connection 2.5 mm² (3P) 20 PC-BTWP 2.5/3 10288982 18,00

Cross-connection 2.5 mm² (4P) 15 PC-BTWP 2.5/4 10288983 24,00

Cross-connection 2.5 mm² (10P) 5 PC-BTWP 2.5/10 10288984 57,00

Cross-connection 4 mm² (2P) 25 PC-BTWP 4/2 10288985 15,00

Cross-connection 4 mm² (3P) 20 PC-BTWP 4/3 10288986 22,00

Cross-connection 4 mm² (4P) 15 PC-BTWP 4/4 10288987 29,00

Cross-connection 4 mm² (10P) 5 PC-BTWP 4/10 10288988 69,00

Cross-connection 6 mm² (2P) 25 PC-BTWP 6/2 10288989 16,00

Cross-connection 6 mm² (3P) 20 PC-BTWP 6/3 10288990 22,00

Cross-connection 6 mm² (4P) 15 PC-BTWP 6/4 10288991 29,00

Cross-connection 6 mm² (10P) 5 PC-BTWP 6/10 10288992 70,00

Cross-connection 10 mm² (2P) 25 PC-BTWP 10/2 10288993 17,00

Cross-connection 10 mm² (3P) 20 PC-BTWP 10/3 10288994 24,00

Cross-connection 10 mm² (4P) 15 PC-BTWP 10/4 10288995 31,00

Cross-connection 10 mm² (10P) 5 PC-BTWP 10/10 10288996 76,00

Cross-connection 16 mm² (2P) 25 PC-BTWP 16/2 10288997 22,00

Cross-connection 16 mm² (3P) 20 PC-BTWP 16/3 10288998 32,00

Cross-connection 16 mm² (4P) 15 PC-BTWP 16/4 10288999 43,00

Cross-connection 16 mm² (10P) 5 PC-BTWP 16/10 10289000 105,00

Cross-connection 35 mm² (2P) 25 PC-BTWP 35/2 10289001 43,00

Cross-connection 35 mm² (3P) 20 PC-BTWP 35/3 10289002 65,00

Cross-connection 35 mm² (4P) 15 PC-BTWP 35/4 10289003 79,00

Cross-connection 35 mm² (10P) 5 PC-BTWP 35/10 10289004 164,00

Cross-connection 2.5 mm² (2P) 25 PC-BTWT 2.5/2 10289005 13,00

Cross-connection 2.5 mm² (3P) 20 PC-BTWT 2.5/3 10289006 20,00

Cross-connection 2.5 mm² (4P) 15 PC-BTWT 2.5/4 10289007 27,00

Cross-connection 2.5 mm² (10P) 5 PC-BTWT 2.5/10 10289008 61,00

Terminal Blocks

SPRING CLAMP TERMINAL BLOCKS - BTWM

TERMINAL

BLOCKDESCRIPTION CROSS - SECTION (mm2) PACKAGING TYPE SAP CODE

PRICE EACH

(ZAR)

Standard

Terminal 2.5 mm² 2.5 100 BTWM 2.5-CZ 750 V 10289013 10,00

Terminal 2.5 mm² (blue) 2.5 100 BTWM 2.5-AZ 750 V 10289583 10,00

Terminal 2.5 mm² (green) 2.5 100 BTWM 2.5-VD 750 V 10289584 10,00

Terminal 2.5 mm² (red) 2.5 100 BTWM 2.5-VM 750 V 11458186 15,00

Terminal 4 mm² 4 100 BTWM 4-Cz 750 V 10289014 15,00

Terminal 4 mm² (blue) 4 100 BTWM 4-Az 750 V 10289585 15,00

Terminal 4 mm² (green) 4 100 BTWM 4-VD 750 V 10289586 15,00

Terminal 4 mm² (red) 4 100 BTWM 4-VM 750 V 11458187 22,00

Terminal 6 mm² 6 100 BTWM 6-Cz 750 V 10289015 22,00

Terminal 6 mm² (blue) 6 100 BTWM 6-AZ 750 V 10289587 22,00

Terminal 6 mm² (green) 6 100 BTWM 6-VD 750 V 10289588 22,00

Terminal 6 mm² (red) 6 100 BTWM 6-VM 750 V 11458198 31,00

Terminal 10 mm² 10 100 BTWM 10-CZ 750 V 10289016 31,00

Terminal 10 mm² (blue) 10 100 BTWM 10-Az 750 V 10289589 31,00

Terminal 10 mm² (green) 10 100 BTWM 10-VD 750 V 10289590 31,00

Terminal 10 mm² (red) 10 100 BTWM 10-VM 750 V 11458199 31,00

Earth type

Earth terminal 2.5 mm² 2.5 50 BTWM 2.5T-VD/AM 10289017 43,00

Earth terminal 4 mm² 4 50 BTWM 4T-VD/AM 10289018 43,00

Earth terminal 6 mm² 6 40 BTWM 6T-VD/AM 10289019 62,00

Earth terminal 10 mm² 10 30 BTWM 10T-Vd/Am 10289020 49,00

Double earth terminal 2.5 mm² 2.5 50 BTWM 2.5CT-Vd/Am 10289960 27,00

Double type

Double terminal 2.5 mm² 2.5 50 BTWM 2.5-2F-Cz 500 V 10289021 30,00

Double terminal 4 mm² 4 50 BTWM 4-2F-Cz 750 V 10289022 30,00

Double terminal 4 mm² w/ jumper 4 20 BTWM 4-2FK 11031843 56,00

Triple type

Triple terminal 2.5 mm² 2.5 20 BTWM 2.5-3F-CZ 500 V 10289023 72,00

Terminal 2P+T 2.5 mm² 2.5 20 BTWM 2.5-2FT-CZ 500 V 10289024 86,00

Terminal 3P+T 2.5 mm² 2.5 20 BTWM 2.5-3FT-Cz 500 V 10289025 86,00

Sensor type Sensor term. 2.5 mm² 2.5 20 BTWM 3S-CZ 500 V 10289026 #N/A

Disconnect Disconnect term. 2.5 mm² 2.5 50 BTWM 2.5A-CZ 750 V 10289027 55,00

Fuse terminalFuse terminal 4 mm² 4 20 BTWM S-Cz 500 V 10289028 61,00

Fuse terminal 4 mm² 4 20 BTWM I-Cz 500 V 10289030 61,00

Fuse terminal

w/ LED

Fuse terminal 6 mm² w/ 24 V dc/cc LED 4 20 BTWM SLD-CZ C03 10289029 99,00

Fuse terminal 6 mm² w/ 110 V ac/ca LED 4 20 BTWM SLD-CZ D13 10847582 99,00

Fuse terminal 6 mm² w/ 220 V ac/ca LED 4 20 BTWM SLD-Cz D23 10847583 18,00

Special typeTerminal 1IN 2OUT 2.5 mm² 2.5 50 BTWM 2.5E-CZ 750 V 10289958 24,00

Terminal 2IN 2OUT 2.5 mm² 2.5 50 BTWM 2.5C-Cz 750 V 10289959 24,00

Page 197: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

390 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 391

Terminal Blocks

ACCESSORIES FOR SPRING CLAMP TYPE TERMINAL BLOCKS

ACCESSORY DESCRIPTION PACKAGING TYPESTOCK

CODE

PRICE EACH

(ZAR)

End plate

End plate 100 TF-BTWM 2.5 C 10289963 4,00

End plate blue 100 TF-BTWM 2.5 (AZ) 10289591 4,00

End plate green 100 TF-BTWM 2.5 (VD) 10289592 4,00

End plate red 100 TF-BTWM 2.5 R 11461175 4,00

End plate 100 TF-BTWM 4 C 10289964 6,00

End plate blue 100 TF-BTWM 4 (AZ) 10289593 6,00

End plate green 100 TF-BTWM 4 (VD) 10289594 6,00

End plate red 100 TF-BTWM 4 R 11461177 6,00

End plate 100 TF-BTWM 6 C 10289965 6,00

End plate blue 100 TF-BTWM 6 (AZ) 10289595 6,00

End plate green 100 TF-BTWM 6 (VD) 10289596 6,00

End plate red 100 TF-BTWM 6 R 11461208 6,00

End plate 100 TF-BTWM 10 C 10289966 7,00

End plate blue 100 TF-BTWM 10 (AZ) 10289597 7,00

End plate green 100 TF-BTWM 10 (VD) 10261778 7,00

End plate red 100 TF-BTWM 10 R 11461210 7,00

End plate 10 TF-BTWM 2.5CT (VD) 10289042 8,00

End plate 50 TF-BTWM 2.5-2F C 10289032 10,00

End plate 25 TF-BTWM 4-2F C 10289033 8,00

End plate 10 TF-BTWM 2.5-3F C 10289034 11,00

End plate 10 TF-BTWM 2.5-3FT 10289036 11,00

End plate 10 TF-BTWM 3S C 10289037 11,00

End plate 10 TF-BTWM 2.5A C 10289038 6,00

End plate 10 TF-BTWM S-I C 10289039 8,00

End plate 10 TF-BTWM 2.5E C 10289040 6,00

Cross-

connection

Cross-connection 2.5 mm² (2P) 25 PC-BTWM 2.5/2 10289044 8,00

Cross-connection 2.5 mm² (3P) 20 PC-BTWM 2.5/3 10289045 13,00

Cross-connection 2.5 mm² (4P) 15 PC-BTWM 2.5/4 10289046 14,00

Cross-connection 2.5 mm² (10P) 5 PC-BTWM 2.5/10 10289047 31,00

Cross-connection 4 mm² (2P) 25 PC-BTWM 4/2 10289048 9,00

Cross-connection 4 mm² (3P) 20 PC-BTWM 4/3 10289049 13,00

Cross-connection 4 mm² (4P) 15 PC-BTWM 4/4 10289050 16,00

Cross-connection 4 mm² (10P) 5 PC-BTWM 4/10 10289051 33,00

Cross-connection 6 mm² (2P) 25 PC-BTWM 6/2 10289052 12,00

Cross-connection 6 mm² (3P) 20 PC-BTWM 6/3 10289053 16,00

Cross-connection 6 mm² (4P) 15 PC-BTWM 6/4 10289054 20,00

Cross-connection 6 mm² (10P) 5 PC-BTWM 6/10 10289055 47,00

Cross-connection 10 mm² (2P) 25 PC-BTWM 10/2 10289056 20,00

Cross-connection 10 mm² (3P) 20 PC-BTWM 10/3 10289057 30,00

Cross-connection 10 mm² (4P) 15 PC-BTWM 10/4 10289058 39,00

Cross-connection 10 mm² (10P) 5 PC-BTWM 10/10 10289059 83,00

Terminal Blocks

GENERAL ACCESSORIES FOR SCREW AND SPRING CLAMP TYPE TERMINAL BLOCKS

TAG TYPE INSCRIPTION LABELS PER PACK TYPE SAP CODEPACK PRICE

(ZAR)

Pack of tags type IDB5-BTW printed at

the horizontal position

" A " 50 IDB5-BTWH-A 10872745 24,00

" B " 50 IDB5-BTWH-B 10872758 24,00

" C " 50 IDB5-BTWH-C 10872759 24,00

" D " 50 IDB5-BTWH-D 10872763 24,00

" E " 50 IDB5-BTWH-E 10872766 24,00

" F " 50 IDB5-BTWH-F 10872768 24,00

" G " 50 IDB5-BTWH-G 10872769 24,00

" H " 50 IDB5-BTWH-H 10872771 24,00

" I " 50 IDB5-BTWH-I 10872773 24,00

" J " 50 IDB5-BTWH-J 10872776 24,00

" K " 50 IDB5-BTWH-K 10872778 24,00

" L " 50 IDB5-BTWH-L 10872781 24,00

" M " 50 DB5-BTWH-M 10872785 24,00

" N " 50 IDB5-BTWH-N 10872788 24,00

" O " 50 IDB5-BTWH-O 10872790 24,00

" P " 50 IDB5-BTWH-P 10872821 24,00

" Q " 50 IDB5-BTWH-Q 10872822 24,00

" X " 50 IDB5-BTWH-X 10872823 24,00

" Y " 50 IDB5-BTWH-Y 10872853 24,00

" Z " 50 IDB5-BTWH-Z 10883452 24,00

"A...Z. A...X" 50 DB5-BTWH-A-Z/A-X 10873759 24,00

" R1 " 50 IDB5-BTWH-R1 10873595 24,00

" R2 " 50 IDB5-BTWH-R2 10873596 24,00

" R3 " 50 IDB5-BTWH-R3 10873597 24,00

" R4 " 50 IDB5-BTWH-R4 10873639 24,00

" R5 " 50 IDB5-BTWH-R5 10873640 24,00

" R6 " 50 IDB5-BTWH-R6 10873634 24,00

" R7 " 50 IDB5-BTWH-R7 10873636 24,00

" R8 " 50 IDB5-BTWH-R8 10873632 24,00

" R9 " 50 IDB5-BTWH-R9 10873689 24,00

" S1 " 50 IDB5-BTWH-S1 10873826 24,00

" S2 " 50 IDB5-BTWH-S2 10873827 24,00

" S3 " 50 IDB5-BTWH-S3 10873859 24,00

" S4 " 50 IDB5-BTWH-S4 10873861 24,00

" S5 " 50 IDB5-BTWH-S5 10873864 24,00

" S6 " 50 IDB5-BTWH-S6 10873866 24,00

" S7 " 50 IDB5-BTWH-S7 10873924 24,00

" S8 " 50 IDB5-BTWH-S8 10873925 24,00

" S9 " 50 IDB5-BTWH-S9 10873926 24,00

" T1 " 50 IDB5-BTWH-T1 10874055 24,00

" T2 " 50 IDB5-BTWH-T2 10874057 24,00

" T3 " 50 IDB5-BTWH-T3 10874068 24,00

" T4 " 50 IDB5-BTWH-T4 10874069 24,00

" T5 " 50 IDB5-BTWH-T5 10874070 24,00

" T6 " 50 IDB5-BTWH-T6 10874071 24,00

" T7 " 50 IDB5-BTWH-T7 10874072 24,00

" T8 " 50 IDB5-BTWH-T8 10874073 24,00

" T9 " 50 IDB5-BTWH-T9 10874074 24,00

" U1 " 50 IDB5-BTWH-U1 10874359 24,00

" U2 " 50 IDB5-BTWH-U2 10874361 24,00

" U3 " 50 IDB5-BTWH-U3 10874363 24,00

" U4 " 50 IDB5-BTWH-U4 10874364 24,00

" U5 " 50 IDB5-BTWH-U5 10874365 24,00

" U6 " 50 IDB5-BTWH-U6 10874366 24,00

" U7 " 50 IDB5-BTWH-U7 10874367 24,00

Page 198: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

392 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 393

Terminal Blocks

GENERAL ACCESSORIES FOR SCREW AND SPRING CLAMP TYPE TERMINAL BLOCKS

TAG TYPE INSCRIPTION LABELS PER PACK TYPE SAP CODEPACK PRICE

(ZAR)

Pack of tags type IDB5-BTW printed at

the horizontal position

" U8 " 50 IDB5-BTW U8 10874388 24,00

" U9 " 50 IDB5-BTW U9 10874389 24,00

" V1 " 50 IDB5-BTW V1 11062052 24,00

" V2 " 50 IDB5-BTW V2 11062053 24,00

" V3 " 50 IDB5-BTW V3 11062054 24,00

" V4 " 50 IDB5-BTW V4 11062101 24,00

" V5 " 50 IDB5-BTW V5 10874527 24,00

" V6 " 50 IDB5-BTW V6 10874568 24,00

" V7 " 50 IDB5-BTW V7 10874569 24,00

" V8 " 50 IDB5-BTW V8 10874570 24,00

" V9 " 50 IDB5-BTW V9 10874571 24,00

" W1 " 50 IDB5-BTW W1 10874731 24,00

" W2 " 50 IDB5-BTW W2 10874732 24,00

" W3 " 50 IDB5-BTW W3 10874733 24,00

" W4 " 50 IDB5-BTW W4 10874734 24,00

" W5 " 50 IDB5-BTW W5 10874735 24,00

" W6 " 50 IDB5-BTW W6 10874737 24,00

" W7 " 50 IDB5-BTW W7 10874748 24,00

" W8 " 50 IDB5-BTW W8 10874749 24,00

" W9 " 50 IDB5-BTW W9 10874751 24,00

" 0 " 50 IDB5-BTW 0 10792234 24,00

" 1 " 50 IDB5-BTW 1 10795114 24,00

" 2 " 50 IDB5-BTW 2 10795183 24,00

" 3 " 50 IDB5-BTW 3 10795196 24,00

" 4 " 50 IDB5-BTW 4 10795212 24,00

" 5 " 50 IDB5-BTW 5 10795219 24,00

" 6 " 50 IDB5-BTW 6 10795250 24,00

" 7 " 50 IDB5-BTW 7 10795255 24,00

" 8 " 50 IDB5-BTW 8 10795258 24,00

" 9 " 50 IDB5-BTW 9 10795267 24,00

" 10 " 50 IDB5-BTW 10 10795284 24,00

"1...10" (5x) 50 IDB5-BTW 1-10 10795289 24,00

"11...20" (5x) 50 IDB5-BTW 11-20 10795291 24,00

"21...30" (5x) 50 IDB5-BTW 21-30 10795303 24,00

"31...40" (5x) 50 IDB5-BTW 31-40 10795373 24,00

"41...50" (5x) 50 IDB5-BTW 41-50 10795411 24,00

"1...50" 50 IDB5-BTW 1-50 10795444 24,00

"51...100" 50 IDB5-BTW 51-100 10795446 24,00

" R " 50 IDB5-BTW R 10795481 24,00

" S " 50 IDB5-BTW S 10795483 24,00

" T " 50 IDB5-BTW T 10795512 24,00

" U " 50 IDB5-BTW U 10795614 24,00

" V " 50 IDB5-BTW V 10795616 24,00

" W " 50 IDB5-BTW W 10795620 24,00

" + " 50 IDB5-BTW + 10795622 24,00

" - " 50 IDB5-BTW - 10795624 24,00

50 IDB5-BTW TERRA 10795626 24,00

101-150 50 IDB5-BTWH-101-150 11070272 24,00

151-200 50 IDB5-BTWH-151-200 11070512 24,00

201-250 50 IDB5-BTWH-201-250 11070562 24,00

251-300 50 IDB5-BTWH-251-300 11070514 24,00

301-350 50 IDB5-BTWH-301-350 11070515 24,00

351-400 50 IDB5-BTWH-351-400 11070516 24,00

401-450 50 IDB5-BTWH-401-450 11070559 24,00

451-500 50 IDB5-BTWH-451-500 11070560 24,00

Terminal Blocks

GENERAL ACCESSORIES FOR SCREW AND SPRING CLAMP TYPE TERMINAL BLOCKS

TAG TYPE INSCRIPTION LABELS PER PACK TYPE SAP CODEPACK PRICE

(ZAR)

Pack of tags type IDB5-BTW

printed at the vertical position

" A " 50 IDB5-BTWV-A 11328896 24,00

" B " 50 IDB5-BTWV-B 11328949 24,00

" C " 50 IDB5-BTWV-C 11328951 24,00

" D " 50 IDB5-BTWV-D 11328956 24,00

" E " 50 IDB5-BTWV-E 11328957 24,00

" F " 50 IDB5-BTWV-F 11127470 24,00

" G " 50 IDB5-BTWV-G 11330749 24,00

" H " 50 IDB5-BTWV-H 11330751 24,00

" I " 50 IDB5-BTWV-I 11330752 24,00

" J " 50 IDB5-BTWV-J 11330753 24,00

" K " 50 IDB5-BTWV-K 11330755 24,00

" L " 50 IDB5-BTWV-L 11330756 24,00

" M " 50 IDB5-BTWV-M 11330789 24,00

" N " 50 IDB5-BTWV-N 11127471 24,00

" O " 50 IDB5-BTWV-O 11330791 24,00

" P " 50 IDB5-BTWV-P 11330793 24,00

" Q " 50 IDB5-BTWV-Q 11330795 24,00

" X " 50 IDB5-BTWV-X 11330797 24,00

" Y " 50 IDB5-BTWV-Y 11330799 24,00

" Z " 50 IDB5-BTWV-Z 11330801 24,00

"A...Z. A...X" 50 DB5-BTWV-A-Z/A-X 11330802 24,00

" R1 " 50 IDB5-BTWV-R1 11331003 24,00

" R2 " 50 IDB5-BTWV-R2 11331004 24,00

" R3 " 50 IDB5-BTWV-R3 11331005 24,00

" R4 " 50 IDB5-BTWV-R4 11331006 24,00

" R5 " 50 IDB5-BTWV-R5 11331007 24,00

" R6 " 50 IDB5-BTWV-R6 11331078 24,00

" R7 " 50 IDB5-BTWV-R7 11331080 24,00

" R8 " 50 IDB5-BTWV-R8 11331081 24,00

" R9 " 50 IDB5-BTWV-R9 11332093 24,00

" S1 " 50 IDB5-BTWV-S1 11331086 24,00

" S2 " 50 IDB5-BTWV-S2 11331098 24,00

" S3 " 50 IDB5-BTWV-S3 11331099 24,00

" S4 " 50 IDB5-BTWV-S4 11331100 24,00

" S5 " 50 IDB5-BTWV-S5 11331102 24,00

" S6 " 50 IDB5-BTWV-S6 11331103 24,00

" S7 " 50 IDB5-BTWV-S7 11331104 24,00

" S8 " 50 IDB5-BTWV-S8 11331105 24,00

" S9 " 50 IDB5-BTWV-S9 11331106 24,00

" T1 " 50 IDB5-BTWV-T1 11331107 24,00

" T2 " 50 IDB5-BTWV-T2 11331118 24,00

" T3 " 50 IDB5-BTWV-T3 11331119 24,00

" T4 " 50 IDB5-BTWV-T4 11331120 24,00

" T5 " 50 IDB5-BTWV-T5 11331121 24,00

" T6 " 50 IDB5-BTWV-T6 11331122 24,00

" T7 " 50 IDB5-BTWV-T7 11331124 24,00

" T8 " 50 IDB5-BTWV-T8 11331125 24,00

" T9 " 50 IDB5-BTWV-T9 11331126 24,00

" U1 " 50 IDB5-BTWV-U1 11331142 24,00

" U2 " 50 IDB5-BTWV-U2 11331143 24,00

" U3 " 50 IDB5-BTWV-U3 11331144 24,00

" U4 " 50 IDB5-BTWV-U4 11331145 24,00

" U5 " 50 IDB5-BTWV-U5 11331146 24,00

" U6 " 50 IDB5-BTWV-U6 11331188 24,00

" U7 " 50 IDB5-BTWV-U7 11331189 24,00

Page 199: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

394 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 395

Terminal Blocks

GENERAL ACCESSORIES FOR SCREW AND SPRING CLAMP TYPE TERMINAL BLOCKS

TAG TYPE INSCRIPTION LABELS PER PACK TYPE SAP CODEPACK PRICE

(ZAR)

Pack of tags type IDB5-BTW

printed at the vertical position

" U8 " 50 IDB5-BTWV-U8 11331190 24,00

" U9 " 50 IDB5-BTWV-U9 11331192 24,00

" V1 " 50 IDB5-BTWV-V1 11331210 24,00

" V2 " 50 IDB5-BTWV-V2 11331213 24,00

" V3 " 50 IDB5-BTWV-V3 11331215 24,00

" V4 " 50 IDB5-BTWV-V4 11331217 24,00

" V5 " 50 IDB5-BTWV-V5 11331248 24,00

" V6 " 50 IDB5-BTWV-V6 11331250 24,00

" V7 " 50 IDB5-BTWV-V7 11331251 24,00

" V8 " 50 IDB5-BTWV-V8 11331253 24,00

" V9 " 50 IDB5-BTWV-V9 11331255 24,00

" W1 " 50 IDB5-BTWV-W1 11331309 24,00

" W2 " 50 IDB5-BTWV-W2 11331311 24,00

" W3 " 50 IDB5-BTWV-W3 11331312 24,00

" W4 " 50 IDB5-BTWV-W4 11331313 24,00

" W5 " 50 IDB5-BTWV-W5 11331314 24,00

" W6 " 50 IDB5-BTWV-W6 11331315 24,00

" W7 " 50 IDB5-BTWV-W7 11331316 24,00

" W8 " 50 IDB5-BTWV-W8 11331319 24,00

" W9 " 50 IDB5-BTWV-W9 11331324 24,00

" 0 " 50 IDB5-BTWV-0 11331326 24,00

" 1 " 50 IDB5-BTWV-1 11331338 24,00

" 2 " 50 IDB5-BTWV-2 11331340 24,00

" 3 " 50 IDB5-BTWV-3 11331341 24,00

" 4 " 50 IDB5-BTWV-4 11331342 24,00

" 5 " 50 IDB5-BTWV-5 11331344 24,00

" 6 " 50 IDB5-BTWV-6 11331345 24,00

" 7 " 50 IDB5-BTWV-7 11331346 24,00

" 8 " 50 IDB5-BTWV-8 11331352 24,00

" 9 " 50 IDB5-BTWV-9 11331353 24,00

" 10 " 50 IDB5-BTWV-10 11331354 24,00

"1...10" (5x) 50 IDB5-BTWV-1-10 11127468 24,00

"11...20" (5x) 50 IDB5-BTWV-11-20 11127766 24,00

"21...30" (5x) 50 IDB5-BTWV-21-30 11127469 24,00

"31...40" (5x) 50 IDB5-BTWV-31-40 11127938 24,00

"41...50" (5x) 50 IDB5-BTWV-41-50 11127939 24,00

"1...50" 50 IDB5-BTWV-1-50 11091565 24,00

"51...100" 50 IDB5-BTWV-51-100 11091912 24,00

" R " 50 IDB5-BTWV-R 11127474 24,00

" S " 50 IDB5-BTWV-S 11127476 24,00

" T " 50 IDB5-BTWV-T 11127473 24,00

" U " 50 IDB5-BTWV-U 11127941 24,00

" V " 50 IDB5-BTWV-V 11127942 24,00

" W " 50 IDB5-BTWV-W 11127945 24,00

" + " 50 IDB5-BTWV-+ 11331399 24,00

" - " 50 IDB5-BTWV- - 11331401 24,00

50 IDB5-BTWV-TERRA 11331403 24,00

101-150 50 IDB5-BTWV-101-150 11331404 24,00

151-200 50 IDB5-BTWV-151-200 11331405 24,00

201-250 50 IDB5-BTWV-201-250 11331407 24,00

251-300 50 IDB5-BTWV-251-300 11331409 24,00

301-350 50 IDB5-BTWV-301-350 11331411 24,00

351-400 50 IDB5-BTWV-351-400 11331412 24,00

401-450 50 IDB5-BTWV-401-450 11331415 24,00

451-500 50 IDB5-BTWV-451-500 11331416 24,00

Terminal Blocks

GENERAL ACCESSORIES FOR SCREW AND SPRING CLAMP TYPE TERMINAL BLOCKS

TAG TYPE INSCRIPTION LABELS PER PACK TYPE SAP CODEPACK PRICE

(ZAR)

Pack of tags type IDG6/5-BTW

printed at the horizontal position

" A " 40 IDG6/5-BTWH-A 10872851 47,00

" B " 40 IDG6/5-BTWH-B 10872854 47,00

" C " 40 IDG6/5-BTWH-C 10872856 47,00

" D " 40 IDG6/5-BTWH-D 10872857 47,00

" E " 40 IDG6/5-BTWH-E 10872858 47,00

" F " 40 IDG6/5-BTWH-F 10872889 47,00

" G " 40 IDG6/5-BTWH-G 10872891 47,00

" H " 40 IDG6/5-BTWH-H 10872893 47,00

" I " 40 IDG6/5-BTWH-I 10872894 47,00

" J " 40 IDG6/5-BTWH-J 10872895 47,00

" K " 40 IDG6/5-BTWH-K 10872897 47,00

" L " 40 IDG6/5-BTWH-L 10872975 47,00

" M " 40 IDG6/5-BTWH-M 10872898 47,00

" N " 40 IDG6/5-BTWH-N 10872900 47,00

" O " 40 IDG6/5-BTWH-O 10872902 47,00

" P " 40 IDG6/5-BTWH-P 10872903 47,00

" Q " 40 IDG6/5-BTWH-Q 10872919 47,00

" X " 40 IDG6/5-BTWH-X 10872921 47,00

" Y " 40 IDG6/5-BTWH-Y 10872922 47,00

" Z " 40 IDG6/5-BTWH-Z 10883455 47,00

"A...Z. A...X" 40 IDG6/5-BTWH-A-Z/A-P 10873746 47,00

" R1 " 40 IDG6/5-BTWH-R1 10873768 47,00

" R2 " 40 IDG6/5-BTWH-R2 10873769 47,00

" R3 " 40 IDG6/5-BTWH-R3 10873770 47,00

" R4 " 40 IDG6/5-BTWH-R4 10873771 47,00

" R5 " 40 IDG6/5-BTWH-R5 10873772 47,00

" R6 " 40 IDG6/5-BTWH-R6 10873774 47,00

" R7 " 40 IDG6/5-BTWH-R7 10873776 47,00

" R8 " 40 IDG6/5-BTWH-R8 10873778 47,00

" R9 " 40 IDG6/5-BTWH-R9 10873780 47,00

" S1 " 40 IDG6/5-BTWH-S1 10873927 47,00

" S2 " 40 IDG6/5-BTWH-S2 10873939 47,00

" S3 " 40 IDG6/5-BTWH-S3 10873940 47,00

" S4 " 40 IDG6/5-BTWH-S4 10873942 47,00

" S5 " 40 IDG6/5-BTWH-S5 10873943 47,00

" S6 " 40 IDG6/5-BTWH-S6 10873945 47,00

" S7 " 40 IDG6/5-BTWH-S7 10873969 47,00

" S8 " 40 IDG6/5-BTWH-S8 10873998 47,00

" S9 " 40 IDG6/5-BTWH-S9 10873999 47,00

" T1 " 40 IDG6/5-BTWH-T1 10874075 47,00

" T2 " 40 IDG6/5-BTWH-T2 10874076 47,00

" T3 " 40 IDG6/5-BTWH-T3 10874077 47,00

" T4 " 40 IDG6/5-BTWH-T4 10874098 47,00

" T5 " 40 IDG6/5-BTWH-T5 10874099 47,00

" T6 " 40 IDG6/5-BTWH-T6 10874100 47,00

" T7 " 40 IDG6/5-BTWH-T7 10874101 47,00

" T8 " 40 IDG6/5-BTWH-T8 10874102 47,00

" T9 " 40 IDG6/5-BTWH-T9 10874103 47,00

" U1 " 40 IDG6/5-BTWH-U1 10874397 47,00

" U2 " 40 IDG6/5-BTWH-U2 10874413 47,00

" U3 " 40 IDG6/5-BTWH-U3 10874414 47,00

" U4 " 40 IDG6/5-BTWH-U4 10874415 47,00

" U5 " 40 IDG6/5-BTWH-U5 10874416 47,00

" U6 " 40 IDG6/5-BTWH-U6 10874440 47,00

" U7 " 40 IDG6/5-BTWH-U7 10874442 47,00

Page 200: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

396 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 397

Terminal Blocks

GENERAL ACCESSORIES FOR SCREW AND SPRING CLAMP TYPE TERMINAL BLOCKS

TAG TYPE INSCRIPTION LABELS PER PACK TYPE SAP CODEPACK PRICE

(ZAR)

Pack of tags type IDG6/5-BTW

printed at the horizontal position

" U8 " 40 IDG6/5-BTWH-U8 10874443 47,00

" U9 " 40 IDG6/5-BTWH-U9 10874459 47,00

" V1 " 40 IDG6/5-BTWH-V1 10874574 47,00

" V2 " 40 IDG6/5-BTWH-V2 10874575 47,00

" V3 " 40 IDG6/5-BTWH-V3 10874576 47,00

" V4 " 40 IDG6/5-BTWH-V4 10874577 47,00

" V5 " 40 IDG6/5-BTWH-V5 10874599 47,00

" V6 " 40 IDG6/5-BTWH-V6 10874603 47,00

" V7 " 40 IDG6/5-BTWH-V7 10874605 47,00

" V8 " 40 IDG6/5-BTWH-V8 10874606 47,00

" V9 " 40 IDG6/5-BTWH-V9 10874607 47,00

" W1 " 40 IDG6/5-BTWH-W1 10874752 47,00

" W2 " 40 IDG6/5-BTWH-W2 10874753 47,00

" W3 " 40 IDG6/5-BTWH-W3 10874754 47,00

" W4 " 40 IDG6/5-BTWH-W4 10874755 47,00

" W5 " 40 IDG6/5-BTWH-W5 10874756 47,00

" W6 " 40 IDG6/5-BTWH-W6 10874757 47,00

" W7 " 40 IDG6/5-BTWH-W7 10874904 47,00

" W8 " 40 IDG6/5-BTWH-W8 10874905 47,00

" W9 " 40 IDG6/5-BTWH-W9 10874907 47,00

" 0 " 40 IDG6/5-BTWH-0 10795627 47,00

" 1 " 40 IDG6/5-BTWH-1 10795640 47,00

" 2 " 40 IDG6/5-BTWH-2 10795642 47,00

" 3 " 40 IDG6/5-BTWH-3 10795660 47,00

" 4 " 40 IDG6/5-BTWH-4 10795662 47,00

" 5 " 40 IDG6/5-BTWH-5 10795665 47,00

" 6 " 40 IDG6/5-BTWH-6 10795667 47,00

" 7 " 40 IDG6/5-BTWH-7 10795681 47,00

" 8 " 40 IDG6/5-BTWH-8 10795683 47,00

" 9 " 40 IDG6/5-BTWH-9 10795685 47,00

" 10 " 40 IDG6/5-BTWH-10 10795687 47,00

"1...10" (5x) 40 IDG6/5-BTWH-1-10 10795698 47,00

"11...20" (5x) 40 IDG6/5-BTWH-11-20 10795700 47,00

"21...30" (5x) 40 IDG6/5-BTWH-21-30 10795705 47,00

"31...40" (5x) 40 IDG6/5-BTWH-31-40 10795706 47,00

"41...50" (5x) 40 IDG6/5-BTWH-41-50 10795707 47,00

"1...50" 40 IDG6/5-BTWH-1-40 10795708 47,00

"51...100" 40 IDG6/5-BTWH-41-80 10795711 47,00

" R " 40 DG6/5-BTWH-81-120 10795712 47,00

" S " 40 IDG6/5-BTWH-R 10795713 47,00

" T " 40 IDG6/5-BTWH-S 10795714 47,00

" U " 40 IDG6/5-BTWH-T 10795716 47,00

" V " 40 IDG6/5-BTWH-U 10795718 47,00

" W " 40 IDG6/5-BTWH-V 10795719 47,00

" + " 40 IDG6/5-BTWH-W 10795720 47,00

" - " 40 IDG6/5-BTWH-+ 10795722 47,00

40 IDG6/5-BTWH- - 10795723 47,00

101-150 40 IDG6/5-BTWH-TERRA 10795726 47,00

151-200 40 DG6/5-BTWH-121-160 11071102 47,00

201-250 40 DG6/5-BTWH-161-200 11071103 47,00

251-300 40 DG6/5-BTWH-201-240 11071544 47,00

301-350 40 DG6/5-BTWH-241-280 11071545 47,00

351-400 40 DG6/5-BTWH-281-320 11071546 47,00

401-450 40 DG6/5-BTWH-321-360 11071547 47,00

451-500 40 DG6/5-BTWH-361-400 11071568 47,00

Terminal Blocks

GENERAL ACCESSORIES FOR SCREW AND SPRING CLAMP TYPE TERMINAL BLOCKS

TAG TYPE INSCRIPTION LABELS PER PACK TYPE SAP CODEPACK PRICE

(ZAR)

Pack of tags type IDG6/5-BTW

printed at the vertical position

" A " 40 IDG6/5-BTWV-A 11332617 47,00

" B " 40 IDG6/5-BTWV-B 11332709 47,00

" C " 40 IDG6/5-BTWV-C 11332710 47,00

" D " 40 IDG6/5-BTWV-D 11332712 47,00

" E " 40 IDG6/5-BTWV-E 11332714 47,00

" F " 40 IDG6/5-BTWV-F 11332715 47,00

" G " 40 IDG6/5-BTWV-G 11332717 47,00

" H " 40 IDG6/5-BTWV-H 11332728 47,00

" I " 40 IDG6/5-BTWV-I 11332730 47,00

" J " 40 IDG6/5-BTWV-J 11332731 47,00

" K " 40 IDG6/5-BTWV-K 11332733 47,00

" L " 40 IDG6/5-BTWV-L 11332734 47,00

" M " 40 IDG6/5-BTWV-M 11332735 47,00

" N " 40 IDG6/5-BTWV-N 11332736 47,00

" O " 40 IDG6/5-BTWV-O 11332737 47,00

" P " 40 IDG6/5-BTWV-P 11332739 47,00

" Q " 40 IDG6/5-BTWV-Q 11332740 47,00

" X " 40 IDG6/5-BTWV-X 11332742 47,00

" Y " 40 IDG6/5-BTWV-Y 11332743 47,00

" Z " 40 IDG6/5-BTWV-Z 11332745 47,00

"A...Z. A...X" 40 IDG6/5-BTWV-A-Z/A-P 11332747 47,00

" R1 " 40 IDG6/5-BTWV-R1 11332947 47,00

" R2 " 40 IDG6/5-BTWV-R2 11332948 47,00

" R3 " 40 IDG6/5-BTWV-R3 11332949 47,00

" R4 " 40 IDG6/5-BTWV-R4 11332950 47,00

" R5 " 40 IDG6/5-BTWV-R5 11332951 47,00

" R6 " 40 IDG6/5-BTWV-R6 11332953 47,00

" R7 " 40 IDG6/5-BTWV-R7 11332954 47,00

" R8 " 40 IDG6/5-BTWV-R8 11332955 47,00

" R9 " 40 IDG6/5-BTWV-R9 11332956 47,00

" S1 " 40 IDG6/5-BTWV-S1 11332957 47,00

" S2 " 40 IDG6/5-BTWV-S2 11332978 47,00

" S3 " 40 IDG6/5-BTWV-S3 11332979 47,00

" S4 " 40 IDG6/5-BTWV-S4 11333050 47,00

" S5 " 40 IDG6/5-BTWV-S5 11333053 47,00

" S6 " 40 IDG6/5-BTWV-S6 11333056 47,00

" S7 " 40 IDG6/5-BTWV-S7 11333059 47,00

" S8 " 40 IDG6/5-BTWV-S8 11333060 47,00

" S9 " 40 IDG6/5-BTWV-S9 11333062 47,00

" T1 " 40 IDG6/5-BTWV-T1 11333065 47,00

" T2 " 40 IDG6/5-BTWV-T2 11333066 47,00

" T3 " 40 IDG6/5-BTWV-T3 11333078 47,00

" T4 " 40 IDG6/5-BTWV-T4 11333081 47,00

" T5 " 40 IDG6/5-BTWV-T5 11333082 47,00

" T6 " 40 IDG6/5-BTWV-T6 11333083 47,00

" T7 " 40 IDG6/5-BTWV-T7 11333085 47,00

" T8 " 40 IDG6/5-BTWV-T8 11333102 47,00

" T9 " 40 IDG6/5-BTWV-T9 11333104 47,00

" U1 " 40 IDG6/5-BTWV-U1 11333106 47,00

" U2 " 40 IDG6/5-BTWV-U2 11333107 47,00

" U3 " 40 IDG6/5-BTWV-U3 11333120 47,00

" U4 " 40 IDG6/5-BTWV-U4 11333121 47,00

" U5 " 40 IDG6/5-BTWV-U5 11333123 47,00

" U6 " 40 IDG6/5-BTWV-U6 11333125 47,00

" U7 " 40 IDG6/5-BTWV-U7 11333127 47,00

Page 201: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

398 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 399

Terminal Blocks

GENERAL ACCESSORIES FOR SCREW AND SPRING CLAMP TYPE TERMINAL BLOCKS

TAG TYPE INSCRIPTION LABELS PER PACK TYPE SAP CODEPACK PRICE

(ZAR)

Pack of tags type IDG6/5-BTW

printed at the vertical position

" U8 " 40 IDG6/5-BTWV-U8 11333138 47,00

" U9 " 40 IDG6/5-BTWV-U9 11333140 47,00

" V1 " 40 IDG6/5-BTWV-V1 11333142 47,00

" V2 " 40 IDG6/5-BTWV-V2 11333143 47,00

" V3 " 40 IDG6/5-BTWV-V3 11333145 47,00

" V4 " 40 IDG6/5-BTWV-V4 11333146 47,00

" V5 " 40 IDG6/5-BTWV-V5 11333149 47,00

" V6 " 40 IDG6/5-BTWV-V6 11333151 47,00

" V7 " 40 IDG6/5-BTWV-V7 11333152 47,00

" V8 " 40 IDG6/5-BTWV-V8 11333154 47,00

" V9 " 40 IDG6/5-BTWV-V9 11333157 47,00

" W1 " 40 IDG6/5-BTWV-W1 11333159 47,00

" W2 " 40 IDG6/5-BTWV-W2 11333160 47,00

" W3 " 40 IDG6/5-BTWV-W3 11333161 47,00

" W4 " 40 IDG6/5-BTWV-W4 11333162 47,00

" W5 " 40 IDG6/5-BTWV-W5 11333163 47,00

" W6 " 40 IDG6/5-BTWV-W6 11333164 47,00

" W7 " 40 IDG6/5-BTWV-W7 11333166 47,00

" W8 " 40 IDG6/5-BTWV-W8 11333188 47,00

" W9 " 40 IDG6/5-BTWV-W9 11333191 47,00

" 0 " 40 IDG6/5-BTWV-0 11333235 47,00

" 1 " 40 IDG6/5-BTWV-1 11333237 47,00

" 2 " 40 IDG6/5-BTWV-2 11333248 47,00

" 3 " 40 IDG6/5-BTWV-3 11333250 47,00

" 4 " 40 IDG6/5-BTWV-4 11333252 47,00

" 5 " 40 IDG6/5-BTWV-5 11333253 47,00

" 6 " 40 IDG6/5-BTWV-6 11333256 47,00

" 7 " 40 IDG6/5-BTWV-7 11333278 47,00

" 8 " 40 IDG6/5-BTWV-8 11333279 47,00

" 9 " 40 IDG6/5-BTWV-9 11333281 47,00

" 10 " 40 IDG6/5-BTWV-10 11333283 47,00

"1...10" (5x) 40 IDG6/5-BTWV-1-10 11333284 47,00

"11...20" (5x) 40 IDG6/5-BTWV-11-20 11333286 47,00

"21...30" (5x) 40 IDG6/5-BTWV-21-30 11333287 47,00

"31...40" (5x) 40 IDG6/5-BTWV-31-40 11333289 47,00

"41...50" (5x) 40 IDG6/5-BTWV-41-50 11333290 47,00

"1...50" 40 IDG6/5-BTWV-1-40 11333292 47,00

"51...100" 40 IDG6/5-BTWV-41-80 11333296 47,00

" R " 40 IDG6/5-BTWV-81-120 11333297 47,00

" S " 40 IDG6/5-BTWV-R 11333309 47,00

" T " 40 IDG6/5-BTWV-S 11333311 47,00

" U " 40 IDG6/5-BTWV-T 11333313 47,00

" V " 40 IDG6/5-BTWV-U 11333315 47,00

" W " 40 IDG6/5-BTWV-V 11333317 47,00

" + " 40 IDG6/5-BTWV-W 11333329 47,00

" - " 40 IDG6/5-BTWV-+ 11333331 47,00

40 IDG6/5-BTWV- - 11333333 47,00

101-150 40 IDG6/5-BTWV-TERRA 11333334 47,00

151-200 40 IDG6/5-BTWV-121-160 11333335 47,00

201-250 40 IDG6/5-BTWV-161-200 11333336 47,00

251-300 40 IDG6/5-BTWV-201-240 11333337 47,00

301-350 40 IDG6/5-BTWV-241-280 11333338 47,00

351-400 40 IDG6/5-BTWV-281-320 11333339 47,00

401-450 40 IDG6/5-BTWV-321-360 11333340 47,00

451-500 40 IDG6/5-BTWV-361-400 11333342 47,00

Terminal Blocks

GENERAL ACCESSORIES FOR SCREW AND SPRING CLAMP TYPE TERMINAL BLOCKS

TAG TYPE INSCRIPTION LABELS PER PACK TYPE SAP CODEPACK PRICE

(ZAR)

Pack of tags type IDG10/5-BTW

printed at the horizontal position

" A " 44 IDG10/5-BTWH-A 10872925 50,00

" B " 44 IDG10/5-BTWH-B 10872938 50,00

" C " 44 IDG10/5-BTWH-C 10872940 50,00

" D " 44 IDG10/5-BTWH-D 10872991 50,00

" E " 44 IDG10/5-BTWH-E 10872992 50,00

" F " 44 IDG10/5-BTWH-F 10872988 50,00

" G " 44 IDG10/5-BTWH-G 10872942 50,00

" H " 44 IDG10/5-BTWH-H 10872944 50,00

" I " 44 IDG10/5-BTWH-I 10872945 50,00

" J " 44 IDG10/5-BTWH-J 10872946 50,00

" K " 44 IDG10/5-BTWH-K 10872969 50,00

" L " 44 IDG10/5-BTWH-L 10872989 50,00

" M " 44 IDG10/5-BTWH-M 10872990 50,00

" N " 44 IDG10/5-BTWH-N 10872993 50,00

" O " 44 IDG10/5-BTWH-O 10872995 50,00

" P " 44 IDG10/5-BTWH-P 10872999 50,00

" Q " 44 IDG10/5-BTWH-Q 10873000 50,00

" X " 44 IDG10/5-BTWH-X 10873001 50,00

" Y " 44 IDG10/5-BTWH-Y 10873002 50,00

" Z " 44 IDG10/5-BTWH-Z 10883456 50,00

"A...Z. A...X" 44 IDG10/5-BTWH-A-Z/A-T 10873747 50,00

" R1 " 44 IDG10/5-BTWH-R1 10873781 50,00

" R2 " 44 IDG10/5-BTWH-R2 10873783 50,00

" R3 " 44 IDG10/5-BTWH-R3 10873786 50,00

" R4 " 44 IDG10/5-BTWH-R4 10873788 50,00

" R5 " 44 IDG10/5-BTWH-R5 10873791 50,00

" R6 " 44 IDG10/5-BTWH-R6 10873789 50,00

" R7 " 44 IDG10/5-BTWH-R7 10873790 50,00

" R8 " 44 IDG10/5-BTWH-R8 10873792 50,00

" R9 " 44 IDG10/5-BTWH-R9 10873793 50,00

" S1 " 44 IDG10/5-BTWH-S1 10873974 50,00

" S2 " 44 IDG10/5-BTWH-S2 10873971 50,00

" S3 " 44 IDG10/5-BTWH-S3 10873975 50,00

" S4 " 44 IDG10/5-BTWH-S4 10873972 50,00

" S5 " 44 IDG10/5-BTWH-S5 10873976 50,00

" S6 " 44 IDG10/5-BTWH-S6 10874001 50,00

" S7 " 44 IDG10/5-BTWH-S7 10873941 50,00

" S8 " 44 IDG10/5-BTWH-S8 10874002 50,00

" S9 " 44 IDG10/5-BTWH-S9 10874004 50,00

" T1 " 44 IDG10/5-BTWH-T1 10874104 50,00

" T2 " 44 IDG10/5-BTWH-T2 10874107 50,00

" T3 " 44 IDG10/5-BTWH-T3 10874118 50,00

" T4 " 44 IDG10/5-BTWH-T4 10874119 50,00

" T5 " 44 IDG10/5-BTWH-T5 10874122 50,00

" T6 " 44 IDG10/5-BTWH-T6 10875464 50,00

" T7 " 44 IDG10/5-BTWH-T7 10874209 50,00

" T8 " 44 IDG10/5-BTWH-T8 10874216 50,00

" T9 " 44 IDG10/5-BTWH-T9 10874233 50,00

" U1 " 44 IDG10/5-BTWH-U1 10875434 50,00

" U2 " 44 IDG10/5-BTWH-U2 10875436 50,00

" U3 " 44 IDG10/5-BTWH-U3 10875437 50,00

" U4 " 44 IDG10/5-BTWH-U4 10875458 50,00

" U5 " 44 IDG10/5-BTWH-U5 10875459 50,00

" U6 " 44 IDG10/5-BTWH-U6 10875460 50,00

Page 202: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

400 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 401

Terminal Blocks

GENERAL ACCESSORIES FOR SCREW AND SPRING CLAMP TYPE TERMINAL BLOCKS

TAG TYPE INSCRIPTION LABELS PER PACK TYPE SAP CODEPACK PRICE

(ZAR)

Pack of tags type IDG10/5-BTW

printed at the horizontal position

" U7 " 44 IDG10/5-BTWH-U7 10875463 50,00

" U8 " 44 IDG10/5-BTWH-U8 10875461 50,00

" U9 " 44 IDG10/5-BTWH-U9 10875462 50,00

" V1 " 44 IDG10/5-BTWH-V1 10874629 50,00

" V2 " 44 IDG10/5-BTWH-V2 10875467 50,00

" V3 " 44 IDG10/5-BTWH-V3 10874636 50,00

" V4 " 44 IDG10/5-BTWH-V4 10874650 50,00

" V5 " 44 IDG10/5-BTWH-V5 10874651 50,00

" V6 " 44 IDG10/5-BTWH-V6 10874654 50,00

" V7 " 44 IDG10/5-BTWH-V7 10874696 50,00

" V8 " 44 IDG10/5-BTWH-V8 10874708 50,00

" V9 " 44 IDG10/5-BTWH-V9 10874711 50,00

" W1 " 44 IDG10/5-BTWH-W1 10874930 50,00

" W2 " 44 IDG10/5-BTWH-W2 10874941 50,00

" W3 " 44 IDG10/5-BTWH-W3 10874968 50,00

" W4 " 44 IDG10/5-BTWH-W4 10874974 50,00

" W5 " 44 IDG10/5-BTWH-W5 10875037 50,00

" W6 " 44 IDG10/5-BTWH-W6 10875048 50,00

" W7 " 44 IDG10/5-BTWH-W7 10875050 50,00

" W8 " 44 IDG10/5-BTWH-W8 10875051 50,00

" W9 " 44 IDG10/5-BTWH-W9 10875053 50,00

" 0 " 44 IDG10/5-BTWH-0 10795739 50,00

" 1 " 44 IDG10/5-BTWH-1 10795742 50,00

" 2 " 44 IDG10/5-BTWH-2 10795744 50,00

" 3 " 44 IDG10/5-BTWH-3 10795747 50,00

" 4 " 44 IDG10/5-BTWH-4 10795758 50,00

" 5 " 44 IDG10/5-BTWH-5 10795760 50,00

" 6 " 44 IDG10/5-BTWH-6 10795899 50,00

" 7 " 44 IDG10/5-BTWH-7 10795901 50,00

" 8 " 44 IDG10/5-BTWH-8 10795904 50,00

" 9 " 44 IDG10/5-BTWH-9 10795905 50,00

" 10 " 44 IDG10/5-BTWH-10 10795928 50,00

" 11 " 44 IDG10/5-BTWH-11 10921286 50,00

1-22 44 IDG10/5-BTWH-1-22 10795931 50,00

23-44 44 IDG10/5-BTWH-23-44 10795937 50,00

1-44 44 IDG10/5-BTWH-1-44 10795946 50,00

45-88 44 IDG10/5-BTWH-45-88 10795948 50,00

89-132 44 IDG10/5-BTWH-89-132 10795951 50,00

" R " 44 IDG10/5-BTWH-R 10795953 50,00

" S " 44 IDG10/5-BTWH-S 10795954 50,00

" T " 44 IDG10/5-BTWH-T 10795955 50,00

" U " 44 IDG10/5-BTWH-U 10795956 50,00

" V " 44 IDG10/5-BTWH-V 10795957 50,00

" W " 44 IDG10/5-BTWH-W 10795961 50,00

" + " 44 IDG10/5-BTWH-+ 10795966 50,00

" - " 44 IDG10/5-BTWH- - 10795991 50,00

44 IDG10/5-BTWH-TERRA 10795994 50,00

11-20 44 IDG10/5-BTWH-11-20 10965302 50,00

133-176 44 IDG10/5-BTWH-133-176 11071569 50,00

177-220 44 IDG10/5-BTWH-177-220 11071570 50,00

221-264 44 IDG10/5-BTWH-221-264 11071571 50,00

265-308 44 IDG10/5-BTWH-265-308 11071572 50,00

309-352 44 IDG10/5-BTWH-309-352 11071573 50,00

353-396 44 IDG10/5-BTWH-353-396 11071639 50,00

397-440 44 IDG10/5-BTWH-397-440 11071640 50,00

Terminal Blocks

GENERAL ACCESSORIES FOR SCREW AND SPRING CLAMP TYPE TERMINAL BLOCKS

TAG TYPE INSCRIPTION LABELS PER PACK TYPE SAP CODEPACK PRICE

(ZAR)

Pack of tags type IDG10/5-BTW

printed at the vertical position

" A " 44 IDG10/5-BTWV-A 11335548 50,00

" B " 44 IDG10/5-BTWV-B 11335549 50,00

" C " 44 IDG10/5-BTWV-C 11335551 50,00

" D " 44 IDG10/5-BTWV-D 11335552 50,00

" E " 44 IDG10/5-BTWV-E 11335554 50,00

" F " 44 IDG10/5-BTWV-F 11335556 50,00

" G " 44 IDG10/5-BTWV-G 11335557 50,00

" H " 44 IDG10/5-BTWV-H 11335559 50,00

" I " 44 IDG10/5-BTWV-I 11335562 50,00

" J " 44 IDG10/5-BTWV-J 11335564 50,00

" K " 44 IDG10/5-BTWV-K 11335567 50,00

" L " 44 IDG10/5-BTWV-L 11335570 50,00

" M " 44 IDG10/5-BTWV-M 11335572 50,00

" N " 44 IDG10/5-BTWH-N 10872993 50,00

" O " 44 IDG10/5-BTWV-O 11335590 50,00

" P " 44 IDG10/5-BTWV-P 11335591 50,00

" Q " 44 IDG10/5-BTWV-Q 11335595 50,00

" X " 44 IDG10/5-BTWV-X 11335597 50,00

" Y " 44 IDG10/5-BTWV-Y 11335609 50,00

" Z " 44 IDG10/5-BTWV-Z 11335610 50,00

"A...Z. A...X" 44 IDG10/5-BTWV-A-Z/A-T 11335611 50,00

" R1 " 44 IDG10/5-BTWV-R1 11335616 50,00

" R2 " 44 IDG10/5-BTWV-R2 11335617 50,00

" R3 " 44 IDG10/5-BTWV-R3 11335635 50,00

" R4 " 44 IDG10/5-BTWV-R4 11335636 50,00

" R5 " 44 IDG10/5-BTWV-R5 11335637 50,00

" R6 " 44 IDG10/5-BTWV-R6 11335668 50,00

" R7 " 44 IDG10/5-BTWV-R7 11335669 50,00

" R8 " 44 IDG10/5-BTWV-R8 11335670 50,00

" R9 " 44 IDG10/5-BTWV-R9 11335671 50,00

" S1 " 44 IDG10/5-BTWV-S1 11335675 50,00

" S2 " 44 IDG10/5-BTWV-S2 11335677 50,00

" S3 " 44 IDG10/5-BTWV-S3 11335678 50,00

" S4 " 44 IDG10/5-BTWV-S4 11335679 50,00

" S5 " 44 IDG10/5-BTWV-S5 11335682 50,00

" S6 " 44 IDG10/5-BTWV-S6 11335684 50,00

" S7 " 44 IDG10/5-BTWV-S7 11335686 50,00

" S8 " 44 IDG10/5-BTWV-S8 11335688 50,00

" S9 " 44 IDG10/5-BTWV-S9 11335689 50,00

" T1 " 44 IDG10/5-BTWV-T1 11335693 50,00

" T2 " 44 IDG10/5-BTWV-T2 11335694 50,00

" T3 " 44 IDG10/5-BTWV-T3 11335696 50,00

" T4 " 44 IDG10/5-BTWV-T4 11335718 50,00

" T5 " 44 IDG10/5-BTWV-T5 11335721 50,00

" T6 " 44 IDG10/5-BTWV-T6 11335723 50,00

" T7 " 44 IDG10/5-BTWV-T7 11335724 50,00

" T8 " 44 IDG10/5-BTWV-T8 11335725 50,00

" T9 " 44 IDG10/5-BTWV-T9 11335727 50,00

" U1 " 44 IDG10/5-BTWV-U1 11335749 50,00

" U2 " 44 IDG10/5-BTWV-U2 11335750 50,00

" U3 " 44 IDG10/5-BTWV-U3 11335755 50,00

" U4 " 44 IDG10/5-BTWV-U4 11335756 50,00

" U5 " 44 IDG10/5-BTWV-U5 11335758 50,00

" U6 " 44 IDG10/5-BTWV-U6 11335759 50,00

" U7 " 44 IDG10/5-BTWV-U7 11335760 50,00

Page 203: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

402 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 403

Terminal Blocks

GENERAL ACCESSORIES FOR SCREW AND SPRING CLAMP TYPE TERMINAL BLOCKS

TAG TYPE INSCRIPTION LABELS PER PACK TYPE SAP CODEPACK PRICE

(ZAR)

Pack of tags type IDG10/5-BTW

printed at the vertical position

" U8 " 44 IDG10/5-BTWV-U8 11335762 50,00

" U9 " 44 IDG10/5-BTWV-U9 11335763 50,00

" V1 " 44 IDG10/5-BTWV-V1 11335764 50,00

" V2 " 44 IDG10/5-BTWV-V2 11335766 50,00

" V3 " 44 IDG10/5-BTWV-V3 11335767 50,00

" V4 " 44 IDG10/5-BTWV-V4 11335788 50,00

" V5 " 44 IDG10/5-BTWV-V5 11335789 50,00

" V6 " 44 IDG10/5-BTWV-V6 11335790 50,00

" V7 " 44 IDG10/5-BTWV-V7 11335791 50,00

" V8 " 44 IDG10/5-BTWV-V8 11335792 50,00

" V9 " 44 IDG10/5-BTWV-V9 11335793 50,00

" W1 " 44 IDG10/5-BTWV-W1 11335794 50,00

" W2 " 44 IDG10/5-BTWV-W2 11335795 50,00

" W3 " 44 IDG10/5-BTWV-W3 11335796 50,00

" W4 " 44 IDG10/5-BTWV-W4 11335797 50,00

" W5 " 44 IDG10/5-BTWV-W5 11335808 50,00

" W6 " 44 IDG10/5-BTWV-W6 11335809 50,00

" W7 " 44 IDG10/5-BTWV-W7 11335810 50,00

" W8 " 44 IDG10/5-BTWV-W8 11335811 50,00

" W9 " 44 IDG10/5-BTWV-W9 11335812 50,00

" 0 " 44 IDG10/5-BTWV-0 11335814 50,00

" 1 " 44 IDG10/5-BTWV-1 11335815 50,00

" 2 " 44 IDG10/5-BTWV-2 11335816 50,00

" 3 " 44 IDG10/5-BTWV-3 11335817 50,00

" 4 " 44 IDG10/5-BTWV-4 11335848 50,00

" 5 " 44 IDG10/5-BTWV-5 11335850 50,00

" 6 " 44 IDG10/5-BTWV-6 11335851 50,00

" 7 " 44 IDG10/5-BTWV-7 11335853 50,00

" 8 " 44 IDG10/5-BTWV-8 11335855 50,00

" 9 " 44 IDG10/5-BTWV-9 11335856 50,00

" 10 " 44 IDG10/5-BTWV-10 11335857 50,00

" 11 " 44 IDG10/5-BTWV-11 11335878 50,00

1-22 44 IDG10/5-BTWV-1-22 11335879 50,00

23-44 44 IDG10/5-BTWV-23-44 11335881 50,00

1-44 44 IDG10/5-BTWV-1-44 11335882 50,00

45-88 44 IDG10/5-BTWV-45-88 11335883 50,00

89-132 44 IDG10/5-BTWV-89-132 11335884 50,00

" R " 44 IDG10/5-BTWV-R 11163385 50,00

" S " 44 IDG10/5-BTWV-S 11163386 50,00

" T " 44 IDG10/5-BTWV-T 11163387 50,00

" U " 44 IDG10/5-BTWV-U 11163398 50,00

" V " 44 IDG10/5-BTWV-V 11163400 50,00

" W " 44 IDG10/5-BTWV-W 11163401 50,00

" + " 44 IDG10/5-BTWV-+ 11335886 50,00

" - " 44 IDG10/5-BTWV- - 11335887 50,00

44 IDG10/5-BTWV-TERRA 11163382 50,00

11-20 44 IDG10/5-BTWV-11-20 11163380 50,00

133-176 44 IDG10/5-BTWV-133-176 11335918 50,00

177-220 44 IDG10/5-BTWV-177-220 11335919 50,00

221-264 44 IDG10/5-BTWV-221-264 11335920 50,00

265-308 44 IDG10/5-BTWV-265-308 11335921 50,00

309-352 44 IDG10/5-BTWV-309-352 11335922 50,00

353-396 44 IDG10/5-BTWV-353-396 11335923 50,00

397-440 44 IDG10/5-BTWV-397-440 11335924 50,00

Terminal Blocks

GENERAL ACCESSORIES FOR SCREW AND SPRING CLAMP TYPE TERMINAL BLOCKS

TAG TYPE INSCRIPTION LABELS PER PACK TYPE SAP CODEPACK PRICE

(ZAR)

Pack of tags type IDG10/6-BTW

printed at the horizontal position

" A " 36 IDG10/6-BTWH-A 10873004 54,00

" B " 36 IDG10/6-BTWH-B 10873006 54,00

" C " 36 IDG10/6-BTWH-C 10873008 54,00

" D " 36 IDG10/6-BTWH-D 10873007 54,00

" E " 36 IDG10/6-BTWH-E 10873009 54,00

" F " 36 IDG10/6-BTWH-F 10873010 54,00

" G " 36 IDG10/6-BTWH-G 10873011 54,00

" H " 36 IDG10/6-BTWH-H 10873013 54,00

" I " 36 IDG10/6-BTWH-I 10873019 54,00

" J " 36 IDG10/6-BTWH-J 10873020 54,00

" K " 36 IDG10/6-BTWH-K 10873014 54,00

" L " 36 IDG10/6-BTWH-L 10873021 54,00

" M " 36 IDG10/6-BTWH-M 10873015 54,00

" N " 36 IDG10/6-BTWH-N 10873016 54,00

" O " 36 IDG10/6-BTWH-O 10873017 54,00

" P " 36 IDG10/6-BTWH-P 10873022 54,00

" Q " 36 IDG10/6-BTWH-Q 10873023 54,00

" X " 36 IDG10/6-BTWH-X 10873028 54,00

" Y " 36 IDG10/6-BTWH-Y 10873029 54,00

" Z " 36 IDG10/6-BTWH-Z 10883457 54,00

"A...Z. A...X" 36 IDG10/6-BTWH-A-Z/A-J 10873745 54,00

" R1 " 36 IDG10/6-BTWH-R1 10873795 54,00

" R2 " 36 IDG10/6-BTWH-R2 10873799 54,00

" R3 " 36 IDG10/6-BTWH-R3 10873802 54,00

" R4 " 36 IDG10/6-BTWH-R4 10873803 54,00

" R5 " 36 IDG10/6-BTWH-R5 10873804 54,00

" R6 " 36 IDG10/6-BTWH-R6 10873806 54,00

" R7 " 36 IDG10/6-BTWH-R7 10873807 54,00

" R8 " 36 IDG10/6-BTWH-R8 10873818 54,00

" R9 " 36 IDG10/6-BTWH-R9 10873821 54,00

" S1 " 36 IDG10/6-BTWH-S1 10874005 54,00

" S2 " 36 IDG10/6-BTWH-S2 10874006 54,00

" S3 " 36 IDG10/6-BTWH-S3 10874007 54,00

" S4 " 36 IDG10/6-BTWH-S4 10874008 54,00

" S5 " 36 IDG10/6-BTWH-S5 10874011 54,00

" S6 " 36 IDG10/6-BTWH-S6 10874012 54,00

" S7 " 36 IDG10/6-BTWH-S7 10874013 54,00

" S8 " 36 IDG10/6-BTWH-S8 10874014 54,00

" S9 " 36 IDG10/6-BTWH-S9 10874048 54,00

" T1 " 36 IDG10/6-BTWH-T1 10874250 54,00

" T2 " 36 IDG10/6-BTWH-T2 10874255 54,00

" T3 " 36 IDG10/6-BTWH-T3 10874309 54,00

" T4 " 36 IDG10/6-BTWH-T4 10874310 54,00

" T5 " 36 IDG10/6-BTWH-T5 10874312 54,00

" T6 " 36 IDG10/6-BTWH-T6 10874315 54,00

" T7 " 36 IDG10/6-BTWH-T7 10874316 54,00

" T8 " 36 IDG10/6-BTWH-T8 10874317 54,00

" T9 " 36 IDG10/6-BTWH-T9 10874341 54,00

" U1 " 36 IDG10/6-BTWH-U1 10874498 54,00

" U2 " 36 IDG10/6-BTWH-U2 10874499 54,00

" U3 " 36 IDG10/6-BTWH-U3 10874500 54,00

" U4 " 36 IDG10/6-BTWH-U4 10874501 54,00

" U5 " 36 IDG10/6-BTWH-U5 10874502 54,00

" U6 " 36 IDG10/6-BTWH-U6 10874503 54,00

" U7 " 36 IDG10/6-BTWH-U7 10874504 54,00

Page 204: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

404 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 405

Terminal Blocks

GENERAL ACCESSORIES FOR SCREW AND SPRING CLAMP TYPE TERMINAL BLOCKS

TAG TYPE INSCRIPTION LABELS PER PACK TYPE SAP CODEPACK PRICE

(ZAR)

Pack of tags type IDG10/6-BTW

printed at the horizontal position

" U8 " 36 IDG10/6-BTWH-U8 10874505 54,00

" U9 " 36 IDG10/6-BTWH-U9 10874506 54,00

" V1 " 36 IDG10/6-BTWH-V1 10874522 54,00

" V2 " 36 IDG10/6-BTWH-V2 10874523 54,00

" V3 " 36 IDG10/6-BTWH-V3 10874524 54,00

" V4 " 36 IDG10/6-BTWH-V4 10874526 54,00

" V5 " 36 IDG10/6-BTWH-V5 10874716 54,00

" V6 " 36 IDG10/6-BTWH-V6 10874717 54,00

" V7 " 36 IDG10/6-BTWH-V7 10874728 54,00

" V8 " 36 IDG10/6-BTWH-V8 10874729 54,00

" V9 " 36 IDG10/6-BTWH-V9 10874730 54,00

" W1 " 36 IDG10/6-BTWH-W1 10875055 54,00

" W2 " 36 IDG10/6-BTWH-W2 10875056 54,00

" W3 " 36 IDG10/6-BTWH-W3 10875059 54,00

" W4 " 36 IDG10/6-BTWH-W4 10875060 54,00

" W5 " 36 IDG10/6-BTWH-W5 10875061 54,00

" W6 " 36 IDG10/6-BTWH-W6 10875063 54,00

" W7 " 36 IDG10/6-BTWH-W7 10875064 54,00

" W8 " 36 IDG10/6-BTWH-W8 10875066 54,00

" W9 " 36 IDG10/6-BTWH-W9 10875088 54,00

" 0 " 36 IDG10/6-BTWH-0 10795997 54,00

" 1 " 36 IDG10/6-BTWH-1 10795999 54,00

" 2 " 36 IDG10/6-BTWH-2 10796004 54,00

" 3 " 36 IDG10/6-BTWH-3 10796008 54,00

" 4 " 36 IDG10/6-BTWH-4 10796012 54,00

" 5 " 36 IDG10/6-BTWH-5 10796014 54,00

" 6 " 36 IDG10/6-BTWH-6 10796016 54,00

" 7 " 36 IDG10/6-BTWH-7 10796019 54,00

" 8 " 36 IDG10/6-BTWH-8 10796027 54,00

" 9 " 36 IDG10/6-BTWH-9 10796041 54,00

" 10 " 36 IDG10/6-BTWH-10 10796042 54,00

1-18 36 IDG10/6-BTWH-1-18 10796043 54,00

19-36 36 IDG10/6-BTWH-19-36 10796044 54,00

1-36 36 IDG10/6-BTWH-1-36 10796045 54,00

37-72 36 IDG10/6-BTWH-37-72 10796046 54,00

73-108 36 IDG10/6-BTWH-73-108 10796047 54,00

" R " 36 IDG10/6-BTWH-R 10796051 54,00

" S " 36 IDG10/6-BTWH-S 10796054 54,00

" T " 36 IDG10/6-BTWH-T 10796056 54,00

" U " 36 IDG10/6-BTWH-U 10796068 54,00

" V " 36 IDG10/6-BTWH-V 10796070 54,00

" W " 36 IDG10/6-BTWH-W 10796072 54,00

" + " 36 IDG10/6-BTWH-+ 10796073 54,00

" - " 36 IDG10/6-BTWH- - 10796076 54,00

36 IDG10/6-BTWH-TERRA 10796090 54,00

109-144 36 IDG10/6-BTWH-109-144 11071641 54,00

145-180 36 IDG10/6-BTWH-145-180 11071642 54,00

181-216 36 IDG10/6-BTWH-181-216 11071576 54,00

217-252 36 IDG10/6-BTWH-217-252 11071588 54,00

253-288 36 IDG10/6-BTWH-253-288 11071591 54,00

289-324 36 IDG10/6-BTWH-289-324 11071593 54,00

325-360 36 IDG10/6-BTWH-325-360 11071540 54,00

361-396 36 IDG10/6-BTWH-361-396 11071541 54,00

397-432 36 IDG10/6-BTWH-397-432 11071542 54,00

Terminal Blocks

GENERAL ACCESSORIES FOR SCREW AND SPRING CLAMP TYPE TERMINAL BLOCKS

TAG TYPE INSCRIPTION LABELS PER PACK TYPE SAP CODEPACK PRICE

(ZAR)

Pack of tags type IDG10/6-BTW

printed at the vertical position

" A " 36 IDG10/6-BTWV-A 11337949 54,00

" B " 36 IDG10/6-BTWV-B 11337971 54,00

" C " 36 IDG10/6-BTWV-C 11337974 54,00

" D " 36 IDG10/6-BTWV-D 11337975 54,00

" E " 36 IDG10/6-BTWV-E 11337988 54,00

" F " 36 IDG10/6-BTWV-F 11328979 54,00

" G " 36 IDG10/6-BTWV-G 11328981 54,00

" H " 36 IDG10/6-BTWV-H 11337990 54,00

" I " 36 IDG10/6-BTWV-I 11337991 54,00

" J " 36 IDG10/6-BTWV-J 11337992 54,00

" K " 36 IDG10/6-BTWV-K 11337993 54,00

" L " 36 IDG10/6-BTWV-L 11337995 54,00

" M " 36 IDG10/6-BTWV-M 11337996 54,00

" N " 36 IDG10/6-BTWV-N 11337997 54,00

" O " 36 IDG10/6-BTWV-O 11337999 54,00

" P " 36 IDG10/6-BTWV-P 11338001 54,00

" Q " 36 IDG10/6-BTWV-Q 11338002 54,00

" X " 36 IDG10/6-BTWV-X 11338003 54,00

" Y " 36 IDG10/6-BTWV-Y 11338004 54,00

" Z " 36 IDG10/6-BTWV-Z 11338005 54,00

"A...Z. A...X" 36 IDG10/6-BTWV-A-Z/A-J 11338006 54,00

" R1 " 36 IDG10/6-BTWV-R1 11338007 54,00

" R2 " 36 IDG10/6-BTWV-R2 11338029 54,00

" R3 " 36 IDG10/6-BTWV-R3 11338030 54,00

" R4 " 36 IDG10/6-BTWV-R4 11338031 54,00

" R5 " 36 IDG10/6-BTWV-R5 11338033 54,00

" R6 " 36 IDG10/6-BTWV-R6 11338034 54,00

" R7 " 36 IDG10/6-BTWV-R7 11338035 54,00

" R8 " 36 IDG10/6-BTWV-R8 11338036 54,00

" R9 " 36 IDG10/6-BTWV-R9 11338037 54,00

" S1 " 36 IDG10/6-BTWV-S1 11338056 54,00

" S2 " 36 IDG10/6-BTWV-S2 11338113 54,00

" S3 " 36 IDG10/6-BTWV-S3 11338114 54,00

" S4 " 36 IDG10/6-BTWV-S4 11338117 54,00

" S5 " 36 IDG10/6-BTWV-S5 11338148 54,00

" S6 " 36 IDG10/6-BTWV-S6 11338151 54,00

" S7 " 36 IDG10/6-BTWV-S7 11338153 54,00

" S8 " 36 IDG10/6-BTWV-S8 11338155 54,00

" S9 " 36 IDG10/6-BTWV-S9 11338157 54,00

" T1 " 36 IDG10/6-BTWV-T1 11338159 54,00

" T2 " 36 IDG10/6-BTWV-T2 11338161 54,00

" T3 " 36 IDG10/6-BTWV-T3 11338163 54,00

" T4 " 36 IDG10/6-BTWV-T4 11338166 54,00

" T5 " 36 IDG10/6-BTWV-T5 11338167 54,00

" T6 " 36 IDG10/6-BTWV-T6 11338178 54,00

" T7 " 36 IDG10/6-BTWV-T7 11338180 54,00

" T8 " 36 IDG10/6-BTWV-T8 11338182 54,00

" T9 " 36 IDG10/6-BTWV-T9 11338183 54,00

" U1 " 36 IDG10/6-BTWV-U1 11338185 54,00

" U2 " 36 IDG10/6-BTWV-U2 11338186 54,00

" U3 " 36 IDG10/6-BTWV-U3 11338187 54,00

" U4 " 36 IDG10/6-BTWV-U4 11338190 54,00

" U5 " 36 IDG10/6-BTWV-U5 11338191 54,00

" U6 " 36 IDG10/6-BTWV-U6 11338193 54,00

" U7 " 36 IDG10/6-BTWV-U7 11338195 54,00

Page 205: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

406 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 407

Terminal Blocks

GENERAL ACCESSORIES FOR SCREW AND SPRING CLAMP TYPE TERMINAL BLOCKS

TAG TYPE INSCRIPTION LABELS PER PACK TYPE SAP CODEPACK PRICE

(ZAR)

Pack of tags type IDG10/6-BTW

printed at the vertical position

" U8 " 36 IDG10/6-BTWV-U8 11338208 54,00

" U9 " 36 IDG10/6-BTWV-U9 11338210 54,00

" V1 " 36 IDG10/6-BTWV-V1 11338243 54,00

" V2 " 36 IDG10/6-BTWV-V2 11338244 54,00

" V3 " 36 IDG10/6-BTWV-V3 11338247 54,00

" V4 " 36 IDG10/6-BTWV-V4 11338250 54,00

" V5 " 36 IDG10/6-BTWV-V5 11338251 54,00

" V6 " 36 IDG10/6-BTWV-V6 11338255 54,00

" V7 " 36 IDG10/6-BTWV-V7 11338257 54,00

" V8 " 36 IDG10/6-BTWV-V8 11338270 54,00

" V9 " 36 IDG10/6-BTWV-V9 11338272 54,00

" W1 " 36 IDG10/6-BTWV-W1 11338273 54,00

" W2 " 36 IDG10/6-BTWV-W2 11338276 54,00

" W3 " 36 IDG10/6-BTWV-W3 11338277 54,00

" W4 " 36 IDG10/6-BTWV-W4 11338278 54,00

" W5 " 36 IDG10/6-BTWV-W5 11338280 54,00

" W6 " 36 IDG10/6-BTWV-W6 11338281 54,00

" W7 " 36 IDG10/6-BTWV-W7 11338284 54,00

" W8 " 36 IDG10/6-BTWV-W8 11338285 54,00

" W9 " 36 IDG10/6-BTWV-W9 11338286 54,00

" 0 " 36 IDG10/6-BTWV-0 11338319 54,00

" 1 " 36 IDG10/6-BTWV-1 11338321 54,00

" 2 " 36 IDG10/6-BTWV-2 11338322 54,00

" 3 " 36 IDG10/6-BTWV-3 11338332 54,00

" 4 " 36 IDG10/6-BTWV-4 11338335 54,00

" 5 " 36 IDG10/6-BTWV-5 11338337 54,00

" 6 " 36 IDG10/6-BTWV-6 11338338 54,00

" 7 " 36 IDG10/6-BTWV-7 11338339 54,00

" 8 " 36 IDG10/6-BTWV-8 11338340 54,00

" 9 " 36 IDG10/6-BTWV-9 11338342 54,00

" 10 " 36 IDG10/6-BTWV-10 11338344 54,00

1-18 36 IDG10/6-BTWV-1-18 11338347 54,00

19-36 36 IDG10/6-BTWV-19-36 11338370 54,00

1-36 36 IDG10/6-BTWV-1-36 11338372 54,00

37-72 36 IDG10/6-BTWV-37-72 11338374 54,00

73-108 36 IDG10/6-BTWV-73-108 11338375 54,00

" R " 36 IDG10/6-BTWV-R 11338376 54,00

" S " 36 IDG10/6-BTWV-S 11338379 54,00

" T " 36 IDG10/6-BTWV-T 11338380 54,00

" U " 36 IDG10/6-BTWV-U 11338381 54,00

" V " 36 IDG10/6-BTWV-V 11338382 54,00

" W " 36 IDG10/6-BTWV-W 11338383 54,00

" + " 36 IDG10/6-BTWV-+ 11338384 54,00

" - " 36 IDG10/6-BTWV- - 11338385 54,00

36 IDG10/6-BTWV-TERRA 11338410 54,00

109-144 36 IDG10/6-BTWV-109-144 11338411 54,00

145-180 36 IDG10/6-BTWV-145-180 11338412 54,00

181-216 36 IDG10/6-BTWV-181-216 11338414 54,00

217-252 36 IDG10/6-BTWV-217-252 11338416 54,00

253-288 36 IDG10/6-BTWV-253-288 11338418 54,00

289-324 36 IDG10/6-BTWV-289-324 11338419 54,00

325-360 36 IDG10/6-BTWV-325-360 11338422 54,00

361-396 36 IDG10/6-BTWV-361-396 11338425 54,00

397-432 36 IDG10/6-BTWV-361-396 11071541 54,00

Terminal Blocks

GENERAL ACCESSORIES FOR SCREW AND SPRING CLAMP TYPE TERMINAL BLOCKS

BUSBAR CONNECTORS

ACCESSORY PACKAGING TYPE STOCK CODEPRICE EACH

(ZAR)

Marking tags for a group of terminals 50 IG-BTW G 10289062 13,00

Marking tags for a group of terminals 25 IG22-BTW 10290296 99,00

Mounting rail / DIN 35 mm (2 m) 1 MR 7.5x30x2000 11476763 22,00

Rail support DIN 25 ST-BTW 10290297 7,00

End bracket 100 PF3-BTW C 10289060 9,00

End bracket 100 PF4-BTW C 10289061 9,00

ACCESSORY PACKAGING TYPE STOCK CODEPRICE EACH

(ZAR)

Fast action fuse cartridge 5x20 mm - 0.25 A 50 RAP 0.25 A 10744040 7,00

Fast action fuse cartridge 5x20 mm - 0.5 A 50 RAP 0.5 A 10744042 7,00

Fast action fuse cartridge 5x20 mm - 1 A 50 RAP 1 A 10744144 7,00

Fast action fuse cartridge 5x20 mm - 2 A 50 RAP 2 A 10744149 7,00

Fast action fuse cartridge 5x20 mm - 4 A 50 RAP 4 A 10744150 7,00

Fast action fuse cartridge 5x20 mm - 6 A 50 RAP 6 A 10744179 9,00

Fast action fuse cartridge 6.3x31.8 mm - 0.25 A 10 RAP 250 mA 10744181 9,00

Fast action fuse cartridge 6.3x31.8 mm - 0.5 A 10 RAP 0.5 A 10744182 9,00

Fast action fuse cartridge 6.3x31.8 mm - 1 A 10 RAP 1 A 10744184 9,00

Fast action fuse cartridge 6.3x31.8 mm - 2 A 10 RAP 2 A 10744187 9,00

Fast action fuse cartridge 6.3x31.8 mm - 4 A 10 RAP 4 A 10744210 9,00

Fast action fuse cartridge 6.3x31.8 mm - 6 A 10 RAP 6 A 10744212 9,00

ACCESSORY PACKAGING TYPE STOCK CODEPRICE EACH

(ZAR)

Connector cross-section / Conector 4 mm² 200 CB4-BTW-Cz 10289075 10,00

Connector cross-section / Conector 10 mm² 100 CB10-BTW-Cz 10289076 22,00

Connector cross-section / Conector 35 mm² 50 CB35-BTW-CZ 10289077 9,00

Connector cross-section / Conector 4 mm² (blue) 100 CB4N-BTW-AZ 10289078 13,00

Connector cross-section / Conector 10 mm² (blue/azul) 100 CB10N-BTW-AZ 10289079 26,00

Connector cross-section / Conector 35 mm² (blue/azul) 50 CB35N-BTW-AZ 10289080 9,00

Connector cross-section / Conector 4 mm² (green-yellow) 100 CB4PE-BTW-VD/AM 10289081 13,00

Connector cross-section / Conector 10 mm² (green-yellow) 100 CB10PE-BTW-VD/AM 10289082 26,00

Connector cross-section / Conector 35 mm² (green-yellow) 50 CB35PE-BTW-VD/AM 10289083 26,00

Busbar 3x10 (1 m) 1 BR 3x10x1000 10667823 9,00

Busbar support block 50 SB-BTW BG 10289084 9,00

Page 206: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

408 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 409

Terminal Blocks

PACK OF CABLE MARKING SLEEVES

BOX OF TAGS FOR CABLE MARKING SLEEVES - WITHOUT PRINT

BOX OF TAGS FOR TERMINAL BLOCKS - WITHOUT PRINT

SELF-ADHESIVE PLATES

GENERAL ACCESSORIES FOR SCREW AND SPRING CLAMP TYPE TERMINAL BLOCKS

DESCRIPTION LENGTH CABLE DIAMETER PACKAGING TYPE STOCK CODEUNIT PRICE EACH

(ZAR)

Cable marking sleeves

15 mm 0.5-1.5 mm² 2000 KKS 15/0.5-1.5 PCT 11506531 2,00

23 mm 0.5-1.5 mm² 2000 KKS 23/0.5-1.5 PCT 11506533 2,00

30 mm 0.5-1.5 mm² 1200 KKS 30/0.5-1.5 PCT 11506534 2,00

15 mm 1.5-2.5 mm² 500 KKS 15/1.5-2.5 PCT 10289086 2,00

23 mm 1.5-2.5 mm² 500 KKS 23/1.5-2.5 PCT 10289087 3,00

30 mm 1.5-2.5 mm² 500 KKS 30/1.5-2.5 PCT 10289088 2,00

15 mm 2.5-4 mm² 500 KKS 15/2.5-4 PCT 10289090 2,00

23 mm 2.5-4 mm² 500 KKS 23/2.5-4 PCT 10289091 3,00

30 mm 2.5-4 mm² 500 KKS 30/2.5-4 PCT 10289092 2,00

15 mm 6-10 mm² 500 KKS 15/6-10 PCT 10289094 3,00

23 mm 6-10 mm² 500 KKS 23/6-10 PCT 10289095 3,00

30 mm 6-10 mm² 200 KKS 30/6-10 PCT 10289096 2,00

15 mm 16-25 mm² 500 KKS 15/16-25 PCT 10289098 3,00

23 mm 16-25 mm² 200 KKS 23/16-25 PCT 10289099 3,00

30 mm 16-25 mm² 2000 KKS 30/16-25 PCT 10289100 4,00

20 mm > 25 mm² 120 KBE-3 PCT 10289121 4,00

DESCRIPTION LENGTH PACKAGING TYPE STOCK CODEUNIT PRICE EACH

(ZAR)

Cable mark. sleeves 15 mm 480 KIP 15 W 10289107 3,00

Cable mark. sleeves 23 mm 240 KIP 23 W 10289109 4,00

Cable mark. sleeves 30 mm 240 KIP 30 W 10289111 2,00

Cable mark. sleeves 20 mm 240 KBEP 209 W 10289119 2,00

DESCRIPTION LENGTH PACKAGING TYPE STOCK CODEUNIT PRICE EACH

(ZAR)

Tags for term. blocks 5x5 mm 500 IDB5-BTW 10290300 2,00

Tags for term. blocks 6x5 mm 400 IDG6/5-BTW 10289068 2,00

Tags for term. blocks 10x5 mm 440 IDG10/5T-BTW 10890902 2,00

Tags for term. blocks 10x6 mm 360 IDG10/6T-BTW 10890908 2,00

DESCRIPTION PACKAGING TYPE STOCK CODEUNIT PRICE EACH

(ZAR)

Plate 27x12.5 mm 120 KLM-27x12.5 10289535 34,00

Plate 45x14 mm 80 KLM-45x14 11349858 48,00

Plate 45x19 mm 56 KLM-45x19 10289525 30,00

Plate 27x18 mm 90 KLM-27x18 10289544 91,00

Plate 70x35 mm 20 KLM-70x35 10289560 190,00

Plate 120x35 mm 10 KLM-120x35 10289566 8,00

Plate 20x8 mm 306 KLM-20x8 11546515 50,00

Plate 60x30 mm 24 KLM-60x30 11546516 46,00

Plate 52x26 mm 35 KLM-52x26 11546517 46,00

Terminal Blocks

GENERAL ACCESSORIES FOR SCREW AND SPRING CLAMP TYPE TERMINAL BLOCKS

PWA3 PLOTTER

PWA4 PLOTTER

ACCESSORIES FOR PLOTTER

DESCRIPTION QUANTITY TYPE SAP CODEPRICE EACH

(ZAR)

Printing system PWA3 - PWA3 10289471 141584,00

Included items

A3 size plotter 1 - - -

Plotting tray for IDG-BTW 1 - 10289481 6992,00

Plotting tray for IDB5-BTW 1 - 10968927 7487,00

Plotter pen 0.25 mm C025-PW 2 - 10289487 4016,00

Plotter ink replacement 5x1 ml CT-PW 1 - 10289508 525,00

Permanent pen (test) 0.30 mm CP030-PW 1 - 10968984 247,00

Plotter ink replacement 30 ml RT-PW 1 - 10289509 960,00

Cleaning kit KL-PW 1 - 10289510 2062,00

Plotter protection cover CP-PW 1 - - -

Plate set for pen cleaning 25 - - -

DESCRIPTION QUANTITY TYPE SAP CODEPRICE EACH

(ZAR)

Printing system PWA4 - PWA4 11380737 93893,00

Included items

A4 size plotter 1 - - -

Plotting tray for IDG-BTW 1 - 10289481 6992,00

Plotting tray for IDB5-BTW 1 - 10968927 7497,00

Plotter pen 0.25 mm C025-PW 2 - 11372704 1977,00

Plate set for pen cleaning 25 - - -

DESCRIPTION QUANTITY TYPE SAP CODEPRICE EACH

(ZAR)

Plotter ink replacement 30 ml 1 RT-PW 10289509 960,00

Plotter ink replacement 5x1 ml 5 CT-PW 10289508 525,00

Disposable plotter pen 0.18 mm 1 C018-PD 11372739 1977,00

Disposable plotter pen 0.25 mm 1 C025-PD 11372704 1977,00

Disposable plotter pen 0.35 mm 1 C035-PD 11372706 1977,00

Disposable plotter pen 0.50 mm 1 C050-PD 11372703 1977,00

Disposable plotter pen 0.70 mm 1 C070-PD 11372705 1977,00

Disposable plotter pen 1.00 mm 1 C100-PD 11372702 1977,00

Rechargeable plotter pen 0.18 mm 1 C018-PW 10289486 4459,00

Rechargeable plotter pen 0.25 mm 1 C025-PW 10289487 4016,00

Rechargeable plotter pen 0.35 mm 1 C035-PW 10289488 3957,00

Rechargeable plotter pen 0.50 mm 1 C050-PW 10289489 4016,00

Rechargeable plotter pen 0.70 mm 1 C070-PW 10289490 3892,00

Rechargeable plotter pen 1.00 m 1 C100-PW 10289491 3892,00

Permanent pen (test) 0.30 mm 1 CP030-PW 10968984 247,00

Cleaning kit (involucre/solvent/flannel) 1 KL-PW 10289510 2062,00

Plotting tray for 1 IDG-PW 10289481 6992,00

Plotting tray for 1 IDB5-PW 10968927 7497,00

Plotting tray for plates 1 KLM-PW 11145242 8894,00

Suction device 1 BS-PW 11615109 1063,00

Pen holder - plotter 1 CPC-PW 11427190 3175,00

Page 207: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

410 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 411

Product Selection

BASIC MOTOR PROTECTION - TYPE “C”

INTERGRAL MOTOR PROTECTION - TYPE”GL”

UNLOAD MOTOR PROTECTION BY COS - TYPE “PF”t

UNLOAD MOTOR PROTECTION BY UNDERCURRENT - TYPE “P”

MOTOR MANAGEMENT SYSTEMS RELAY BASE - TYPE “PBM”

DESCRIPTION ARTICLE NUMBER TYPE STOCK CODE PRICE (ZAR)

1.5-4kW, 3ph Electronic Motor Protection Relay, Range: 3-9.3amp, 115 VAC Control 11202 C9.115V F0000001 1 492.00

1.5-4kW, 3ph Electronic Motor Protection Relay, Range: 3-9.3amp, 230 VAC Control 11203 C9.230V F0000002 1 492.00

5.5-9kW, 3ph Electronic Motor Protection Relay, Range: 9-21.6amp, 115 VAC Control 11222 C21.115V F0000003 1 822.00

5.5-9kW, 3ph Electronic Motor Protection Relay, Range: 9-21.6amp, 230 VAC Control 11223 C21.230V F0000004 1 822.00

11-22kW, 3ph Electronic Motor Protection Relay, Range: 20-45.2amp, 115 VAC Control 11242 C45.115V F0000005 2 282.00

11-22kW, 3ph Electronic Motor Protection Relay, Range: 20-45.2amp, 230 VAC Control 11243 C45.230V F0000006 2 282.00

DESCRIPTIONFANOX

ARTICLE NUMBER

FANOX TYPE STOCK CODE PRICE (ZAR)

2.2-7.5kW, 3ph Electronic Motor Protection Relay, Range: 4-16.7amp, 115 VAC Control 11302 GL16.115V F0000007 2 874.00

2.2-7.5kW, 3ph Electronic Motor Protection Relay, Range: 4-16.7amp, 230 VAC Control 11303 GL16.230V F0000008 2 874.00

7.5-18.5kW,3ph Electronic Motor Protection Relay, Range: 15-40.5amp, 115 VAC

Control11322 GL40.115V F0000009 3 210.00

7.5-18.5kW,3ph Electronic Motor Protection Relay, Range: 15-40.5amp, 230 VAC

Control11323 GL40.230V F0000010 3 210.00

22-45kW, 3ph Electronic Motor Protection Relay, Range: 40-91amp, 115 VAC Control 11342 GL90.115V F0000011 3 468.00

22-45kW, 3ph Electronic Motor Protection Relay, Range: 40-91amp, 230 VAC Control 11343 GL90.230V F0000012 3 468.00

DESCRIPTIONFANOX

ARTICLE NUMBER

FANOX TYPE STOCK CODE PRICE (ZAR)

1.5-7.5kW, 3Ph Pump Protection Relay, Range: 4-16.6amp, 400VAC Control 12165PF16-

R.400VF0000013 2 440.00

7.5-22kW, 3Ph Pump Protection Relay, Range: 16-47.5amp, 400VAC Control 12167PF47-

R.400VF0000014 2 698.00

DESCRIPTIONFANOX

ARTICLE NUMBER

FANOX TYPE STOCK CODE PRICE (ZAR)

3-7kW, 3ph Motor Protection Relay, U/L Protection, Range 7-19.6amp 24VAC/DC

Control11400 P19.24V F0000015 2 788.00

3-7kW, 3ph Motor Protection Relay, U/L Protection, Range 7-19.6amp 115V Control 11402 P19.115V F0000016 2 208.00

3-7kW, 3ph Motor Protection Relay, U/L Protection, Range 7-19.6amp 230V Control 11403 P19.230V F0000017 2 208.00

9.2-20kW, 3ph Motor Protection Relay, U/L Protection, Range 19 - 44.2amp 115V

Control11422 P44.115V F0000018 2 441.00

9.2-20kW, 3ph Motor Protection Relay, U/L Protection, Range 19 - 44.2amp 230V

Control11423 P44.230V F0000019 2 441.00

20-40kW, 3ph Motor Protection Relay, U/L Protection, Range 40- 90.4amp 115V Control 11442 P90.115V F0000020 2 660.00

20-40kW, 3ph Motor Protection Relay, U/L Protection, Range 40 - 90.4amp 230V

Control11443 P90.230V F0000021 2 660.00

DESCRIPTIONFANOX

ARTICLE NUMBER

FANOX TYPE STOCK CODE PRICE (ZAR)

0.8….6A Motor Management Relay, Control Supply 110/230VAC/DC 17000 PBM.B11 F0000022 7 827.00

4….25A Motor Management Relay, Control Supply 110/230VAC/DC 17001 PBM.B51 F0000023 7 827.00

0.8….6A Motor Management Relay, Control Supply 24/48VDC 17002 PBM.B12 F0000024 8 825.00

4….25A Motor Management Relay, Control Supply 24/48VDC 17003 PBM.B52 F0000025 8 825.00

1810,00

2210,00

2210,00

2768,00

2768,00

2768,00

3486,00

3894,00

3894,00

4207,00

4207,00

4207,00

3272,00

3272,00

2678,00

2678,00

2961,00

2961,00

3227,00

3227,00

3227,00

9495,00

9495,00

10705,00

10705,00

Fanox - Electronic Motor Protection Fanox - Electronic Motor Protection

Product Selection

MOTOR MANAGEMENT SYSTEMS - HMI

FANOX - MOTOR PROTECTION RELAY - ACCESSORIES

MOTOR MANAGEMENT SYSTEM - TOROIDAL TRANSFORMERS (CT’s)

THERMISTOR SENSORS

MOTOR MANAGEMENT SYSTEMS - INTERFACE CABLE

SINGLE PHASE PUMP PROTECTION - UNLOAD PROTECTION BY UNDERCURRENT - TYPE “PS”

GENERATOR PROTECTION - TYPE :GEN”

DESCRIPTIONFANOX

ARTICLE NUMBER

FANOX TYPE STOCK CODE PRICE (ZAR)

HMI Display 17006 PBM.HE F0000026 2 999.00

DESCRIPTIONFANOX

ARTICLE NUMBER

FANOX TYPE STOCK CODE PRICE (ZAR)

0.5m Interface cable, from PBM.B RJ45 to PBM.H.RJ45 17008 PBM.C1 F0000027 115.00

1m Interface cable, from PBM.B RJ45 to PBM.H.RJ45 17009 PBM.C2 F0000028 128.00

DESCRIPTIONFANOX

ARTICLE NUMBER

FANOX TYPE STOCK CODE PRICE (ZAR)

0.37-1.5kW, 1Ph Pump Protection Relay, Range: 3-11amp, 230VAC Control 12164 PS11.230V F0000029 1 280.00

DESCRIPTION FANOX ARTICLE NUMBER FANOX TYPE STOCK CODE PRICE (ZAR)

Generator protection Relay Range: 4 - 10,3amp, 24VDC Control 11350 GEN10.24VDC F0000030 2 743.00

DESCRIPTIONFANOX

ARTICLE NUMBER

FANOX TYPE STOCK CODE PRICE (ZAR)

External Display Module for C9/C21/C45 Motor Protection Relay 12530 OD.C F0000031 334.00

External Display Module for GL16/GL40/GL90 Motor Protection Relay 12535 OD.GL F0000032 402.00

External Display Module for Pump Protection Relay 12540 OD.P F0000033 402.00

External Display Module for Pump Protection Relay 12555 OD.PF F0000034 402.00

External Display Module for BG Eex Motor Protection Relay 12505 OD-G F0000035 402.00

External Display Module for Generator Protection Relay 12545 OD.GEN F0000036 365.00

DESCRIPTIONFANOX

ARTICLE NUMBER

FANOX TYPE STOCK CODE PRICE (ZAR)

Ø35mm Internal Diameter 41060 CT1/35 F0000037 848.00

Ø60mm Internal Diameter 41065 CT1/60 F0000038 1 119.00

Ø80mm Internal Diameter 41070 CT1/80 F0000039 1 419.00

Ø110mm Internal Diameter 41075 CT1/110 F0000040 1 838.00

Ø160mm Internal Diameter 41080 CT1/160 F0000041 5 230.00

Ø210mm Internal Diameter 41085 CT1/210 F0000042 5 621.00

DESCRIPTIONFANOX

ARTICLE NUMBER

FANOX TYPE STOCK CODE PRICE (ZAR)

Thermistor Sensor Internal Mounting, 1200C ≥ 1330 Ω 41700 PTC120 F0000043 111.00

Thermistor Sensor External Mounting, 700C ≥ 1330 Ω 41705 PTCEX70 F0000044 92.00

3637,00

155,00

155,00

1553,00

3327,00

488,00

488,00

488,00

488,00

443,00

443,00

1357,00

1721,00

2230,00

6344,00

6819,00

6819,00

111,00

111,00

Page 208: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

412 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 413

Fanox - Electronic Motor Protection

Product Selection

FANOX - CONTROL RELAY

PHASE RELAY - TYPE “S”

EARTH LEAKAGE RELAY - TYPE “ELR”

EARTH LEAKAGE RELAY - TYPE “D300”

FANOX SURGE ARRESTOR - CLASS C - TYPE II

THERMISTOR PROTECTION RELAY - TYPE “MT”

MLTI FUNCTIONAL DIGITAL TIMER - TYPE “MTR”

SINGLE PHASE VOLTAGE RELAY - TYPE “U1”

DESCRIPTIONFANOX

ARTICLE NUMBER

FANOX TYPE STOCK CODE PRICE (ZAR)

Phase Relay 12034 S4.400V F0000045 1 192.00

DESCRIPTIONFANOX

ARTICLE NUMBER

FANOX TYPE STOCK CODE PRICE (ZAR)

Thermistor Protection Relay 12039 MT.230V F0000046 1 088.00

DESCRIPTIONFANOX

ARTICLE NUMBER

FANOX TYPE STOCK CODE PRICE (ZAR)

Multi Function Timer 12110 MTR-10 F0000047 1 954.00

DESCRIPTIONFANOX

ARTICLE NUMBER

FANOX TYPE STOCK CODE PRICE (ZAR)

Control relay 12027 U1D.230V F0000048 1 579.00

DESCRIPTIONFANOX

ARTICLE NUMBER

FANOX TYPE STOCK CODE PRICE (ZAR)

Earth Leakage relay, sensitivity 0.025-25A, Adjustable trip delay 0.02-5s, Control Voltage

110/230VAC41015 ELR.A F0000049 3 045.00

Earth Leakage relay, sensitivity 0.025-25A, Adjustable trip delay 0.02-5s, Control Voltage

110/230VAC41105 ELR.T60 F0000050 3 188.00

Earth Leakage relay, sensitivity 0.025-25A, Adjustable trip delay 0.02-5s, Control Voltage

110/230VAC41000 ELR-3C F0000051 2 316.00

DESCRIPTIONFANOX

ARTICLE NUMBER

FANOX TYPE STOCK CODE PRICE (ZAR)

Earth Leakage relay, sensitivity 0.03 - 30A, Adjustable trip delay 0.02 - 5s, Control Volt-

age 110VAC41020 D30 F0000052 1 899.00

Earth Leakage relay, sensitivity 0.03 - 30A, Adjustable trip delay 0.02 - 5s, Control Volt-

age 230VAC41022 DM30 F0000053 1 994.00

DESCRIPTIONFANOX

ARTICLE NUMBER

FANOX TYPE STOCK CODE PRICE (ZAR)

Single Pole Surge Protector - Class “C” Type II 41600 VP C40 275/1 F0000054 551.00

Double Pole Surge Protector - Class “C” Type II 41603 VP C40 275/2 F0000056 1 081.00

Three Pole Surge Protector - Class “C” Type II 41609 VP C40 250/NPE F0000055 2 208.00

551,00

1081,00

2208,00

1899,00

1994,00

3045,00

3188,00

2316,00

1579,00

1192,00

1088,00

1954,00

Rated Motor Current Conversion Table

Selection Charts

RATED POWER 3 PHASE 4 POLE MOTORS 50-60HZ STAR DELTA FLC X 0.58

KW HP 230V 400V 5 0V 400Vt 440V 500V

0.37 0.5 2.9A 0.98A 0.7

0.55 0.75 4.6A 1.5A

0.75 1 5.7A 1.9A 1.

1.1 1.5 7.3A 2.4A

1.5 2 9.9A 3.3A 2.

2.2 3 14.4A 4.7A .

3 4 19.1A 6.2A

4 5.5 24A 8.1A 4.6A 4.3A 3.7A

5.5 7.5 33A 10.9A 6.4A 6.1A 5.37A

7.5 10 44.7A 14.7A 8.5A 7.8A 6.8A

1 .5 57.3A 19A 10.9A 10A 8.8A

11 15 65A 20.9A 1 . 12.2A 11.7A 10.3A

15 20 86.1A 28.5A 16.5A 15.4A 13.5A

18.5 25 106.1A 35.5A 20.4A 19A 16.7A

22 30 124.3A 41.8A 24.2A 22.6A 19.68A

30 40 170.3A 57A 33A 31.9A 28A

37 50 208.5A 68.4A 39.5A 37A 32.5A

45 60 242.9A 80.7A 46.6A 43.9A 38.6A

55 75 301.3A 99.7A 57.6A 52A 45.7A

75 100 396A 131.1A 76A 72.2A 63.5A

90 125 161.5A 93A 84A 73.9A

110 150 194.7A 112.1A 102A 89.7A

132 180 232.7A 134.4A 124A 109.1A

160 220 285A 164.5A 147.8A 130A

200 270 351.5A 2 203A 185A 162.8A

220 300 389A 225.6A 204.7A 180.3A

250 340 442A 256A 233A 205A

315 430 551A 319A 290A 255A

355 480 617A 358A 325A 284A

5 0 660A 383A 339A 307A

4 742A 430A 391A 344A

RATED POWER 3 PHASE 4 POLE MOTORS 50-60HZ STAR DELTA FLC X 0.58

KW HP 230V 400V (IE3*)550V 400Vt 440V 500V

Information in this table must be used as guidelines only as each motor and installation have their own characteristics which depend on many factors and we cannot be held responsible should there be any discrepancy in these tables

V = Volts I = Amperes %Eff = Percent Efficiency P.F = Power Factor HP = Horsepower

ELECTRICAL FORMULADESIRED DATA AC SINGLE PHASE AC THREE PHASE DIRECT CURRENT

Kilowatt OutputV x I x %Eff x P.F

1000

V x I x 1.73 x %Eff x P.F

1000

1 x V x %Eff

1000

kVAV x I

1000

V x I x 1.73

1000

Horsepower OutputV x I x %Eff x P.F

746

V x I x 1.73 x %Eff x P.F

746

V x I x %Eff

746

Amperes when Horsepower is knownHP x 746

V x %Eff x P.F

HP x 746

1.73 x V x %Eff x P.F

HP x 746

V x %Eff

Amperes when Kilowatts are knownkW x 1000

V x %Eff x P.F

kW x 1000

1.73 x V x %Eff x P.F

kW x 1000

V x %Eff

Amperes when kVA are knownkVA x 1000

V

kVA x 1000

1.73 x V

12.70

519.00

585.00

4 742A 641.00500

Page 209: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

ALL PRICES EXCLUDE VAT, E&OE ALL PRICES EXCLUDE VAT, E&OE

www.zest.co.za

414 l LOW VOLTAGE SWITCH & CONTROL GEAR

www.zest.co.za

LOW VOLTAGE SWITCH & CONTROL GEAR l 415

1. The Customer agrees that (a) this Agreement represents the entire Agre-

ement between the Customer and Zest Electric Motors (Pty) Ltd (herei-

nafter called Zest) and that no alterations or additions to this Agreement

may be effected unless agreed to by both parties, reduced to writing and

signed by the Customer and a duly authorised representative of Zest; (b)

this Agreement will govern all future contractual relationships between the

parties; (c) this Agreement is applicable to all existing debts and future

debts between the parties; (d) this Agreement is final and binding and is

not subject to any suspensive or resolutive terms or conditions; (e) any

conflicting conditions stipulated by the Customer are expressly excluded;

(f) these terms supersede all previous conditions of Agreement without

prejudice to any securities or guarantees held by Zest and (g) these terms

apply to all servants and subcontractors of Zest.

2.1 This Agreement only becomes final and binding on receipt and accep-

tance of this offer by Zest at its business address in Linbro Park.

2.2 Any order only becomes final and binding on receipt and acceptance

of such order by Zest at its business address per clause 2.1.

3. The signatory hereby binds himself / herself in his / her personal capacity

as Shareholder (in the case of a company), Member (in the case of a close

corporation) or Owner or Partner as co-debtor jointly and severally for the

full amount due to Zest and agrees that these Standard Conditions will

apply in the exact same way to him / her.

4. The Customer acknowledges that it does not rely on any represen-

tations made by Zest in regard to the goods and services or any of its

qualities leading up to this Agreement other than those contained in this

Agreement. All specifications, price lists, performance figures, advertise-

ments, brochures and other technical data furnished by Zest in respect of

the goods or services orally or in writing will not form part of the Agreement

in any way unless agreed to in writing by Zest.

5.1 The Customer agrees that neither Zest nor any of its employees will be

liable for any negligent or innocent misrepresentations made to the Cus-

tomer.

5.2 It is the sole responsibility of the Customer to determine that the goods

or services ordered are suitable for the purposes of intended use.

5.3 The Customer agrees to pay all additional costs resulting from any acts

or omissions by the Customer including suspension of work, modification

of requirements, failure or delay in giving particulars required to enable

work to proceed on schedule or requirements that work be completed

earlier than agreed.

5.4 Zest reserves the right at its sole discretion to provide alternative goods

of the same quality and quantity at the prevailing prices to those ordered

by the Customer should such goods be superseded, replaced or their

manufacture terminated.

6.1 All quotations will remain valid for a period of 60 days from the date

of the quotation or until the date of issue of a new Price List, whichever

occurs first.

6.2 All quotations are subject to the availability of the goods or services

and subject to correction of good faith errors by Zest and the prices quo-

ted are subject to any increases in the cost price, including currency fluc-

tuations, of Zest before acceptance of the order.

6.3 If the Customer disputes the amount of increase, the amount of the

increase may be certified by any independent auditor and such certificate

shall be final and binding on the Customer.

6.4 The Customer hereby confirms that the goods or services on any Tax

Invoice issued duly represent the goods or services ordered by the Custo-

mer at the prices agreed to by the Customer and, where delivery / perfor-

mance has already taken place, that the goods or services were inspected

and that the Customer is satisfied that these conform in all respects to the

quality and quantity ordered and are free from any defects.

6.5 Notwithstanding the provisions of clause 1 above, all orders or agreed

variations to orders, whether orally or in writing, shall be binding and sub-

ject to these Standard Conditions of Agreement and may not be revoked

by the Customer.

6.6 Zest shall be entitled in its sole discretion to split the delivery / perfor-

mance of the goods or services ordered in the quantities and on the dates

it decides.

6.7 Zest shall be entitled to invoice each delivery / performance actually

made separately.

6.8 Any delivery note, waybill or job card (copy or original) signed by the

Customer or a third party engaged to transport the goods and held by Zest

shall be prima facie proof that delivery was made to the Customer.

6.9 The risk of damage to, destruction or theft of goods shall pass to the

Customer on acceptance of any order placed in terms of this Agreement

and the Customer undertakes to comprehensively insure the goods until

paid for in full. Zest may recover insurance premiums from the Customer

for such ordered and uninsured goods.

6.10 Delivery and performance times quoted are merely estimates and are

not binding on Zest.

6.11 If Zest agrees to engage a third party to transport the goods, Zest is

hereby authorised to engage a third party on the Customer's behalf and on

the terms deemed fit by Zest.

6.12 The Customer indemnifies Zest against any claims against Zest that

may arise from such agreement in clause 6.11.

6.13 Repair times and repair costs given are merely estimates and are not

binding on Zest

6.14 Any item handed in for repair may be sold by Zest to defray the cost

of such repairs if the item remains uncollected within 30 days of the repairs

being completed.

6.15 All goods taken on an evaluation, approval or demonstration basis

by the Customer are deemed sold if not returned within 7 days of issue

in the original condition, in the original packaging and with all accessories

and manuals intact.

6.16 The Customer acknowledges that it remains liable for VAT payment

as per the Tax Invoice unless the necessary exemption certificate has been

lodged with Zest.

6.17 In the event of the Customer being unable or unwilling to view and

accept final drawings of custom ordered goods, the drawings will be dee-

med correct and accepted unless otherwise indicated by the Customer in

writing within 5 days of such proof being sent to the Customer.

7.1 New goods are guaranteed according to the Manufacturer's product

specific warranties only

and all other guarantees including common law guarantees are hereby

specifically excluded.

Services carry no guarantee.

7.2 Liability under clause 7.1 is restricted to the cost of repair or replace-

ment of faulty goods or services or granting of a credit at the sole discretion

of Zest.

7.3 No claim under this Agreement shall arise unless the Customer has,

within 3 days of an alleged breach of contract and/or defect occurring,

given Zest written notice by prepaid registered post of such breach or

defect, and has afforded Zest at least 30 days to rectify such defect or

breach.

7.4 To be valid, claims must be supported by the original Tax Invoice.

7.5 The Customer shall return any defective moveable goods to the pre-

mises of Zest at the Customer's own cost and packed in the original or

suitable packaging and all risks for the duration of repair remain with the

Customer.

7.6 All guarantees are immediately null and void should any goods be tam-

pered with or should the seals on goods be broken by anyone other than

Zest or should the goods be used or stored outside the Manufacturer's

specifications.

8.1 Under no circumstances shall Zest be liable for any consequential da-

mages including loss of profits or for any delictual liability of any nature

whatsoever whether caused negligently or innocently.

8.2 Under no circumstances shall Zest be liable for any damage arising

from any misuse, abuse or neglect of the goods or services.

9. Delivery of the goods or services to the Customer shall take place at the

place of business of Zest.

10.1 The Customer agrees that the amount contained in a Tax Invoice

issued by Zest shall be due and payable unconditionally (a) cash on order;

or (b) if the Customer is a Credit Approved Customer, within 30 days from

the end of the month in which a Tax Invoice has been issued by Zest.

10.2 The Customer agrees to pay the amount on the Tax Invoice at the

offices of Zest.

10.3 The risk of payment by cheque through the post rests with the Cus-

tomer.

11.1 The Customer has no right to withhold payment for any reason what-

soever and agrees that no extension of payment of any nature shall be

extended to the Customer and any such extension will not be applicable

or enforceable unless agreed to by Zest, reduced to writing and signed by

the Customer and a duly authorised representative of Zest.

11.2 The Customer is not entitled to set off any amount due to the Custo-

mer by Zest against this debt.

11.3 All discounts shall be forfeited if payment in full is not made on the

due date.

12.1 The Customer agrees that the amount due and payable to Zest may

be determined and proven by a certificate issued and signed by any di-

rector or manager of Zest, whose authority need not be proven or by any

Standard Conditions Of Agreement

independent auditor. Such certificate shall be binding and shall be prima

facie proof of the indebtedness of the Customer.

12.2 Any printout of computer evidence tendered by any party shall be

admissible evidence and no party shall object to the admissibility of such

evidence purely on grounds that such evidence is computer evidence or

that the requirements of the Electronic Communications and Transactions

Act 25 of 2002 have not been met.

13.1 The Customer agrees that interest shall be payable at the maximum

legal interest rate prescribed by the National Credit Act 34 of 2005 if that

Act is applicable, or at double the repo-rate as declared by the Reserve

Bank from time to time if that Act is not applicable, on any moneys past

due date to Zest and that interest shall be calculated daily and compoun-

ded monthly from the date of acceptance of the order.

13.2 The Customer expressly agrees that no debt owed to Zest by the

Customer shall become prescribed before the passing of a period of six

years from the date the debt falls due.

14.1 The Customer agrees that if an account is not settled in full (a) against

order; or (b) within the period agreed in clause 10.1 above in the case of

a Credit Approved Customer; Zest is: (i) entitled to immediately institute

action against the Customer at the sole expense of the Customer; or (ii)

to cancel the Agreement and take possession of any goods delivered to

the Customer and claim damages. These remedies are without prejudice

to any other right Zest may be entitled to in terms of this Agreement or in

law. Zest reserves its right to stop supply immediately on cancellation or

on non-payment.

14.2 A Credit Approved Customer will forthwith lose this approval when

payment is not made according to the conditions of clause 10.1(b) and

all amounts then outstanding shall immediately become due and payable.

14.3 Zest shall be entitled to withdraw credit facilities at any time within its

sole discretion.

15.1 In the event of cancellation, the Customer shall be liable to pay (a)

the difference between the selling price and the value of the goods at the

time of repossession and (b) all other costs incurred in the repossession of

the goods. The value of repossessed or retained pledged goods shall be

deemed to be the value placed on them by any sworn valuator after such

repossession, and such valuation shall be conclusive proof of the value. If

the goods are not recovered for any reason whatsoever, the value shall be

deemed to be nil.

15.2 In the event of cancellation of the Agreement by Zest, it shall be enti-

tled to repossess any goods that have been delivered to the Customer and

remains unpaid by the due date.

15.3 In the event of cancellation of the Agreement by Zest, it is entitled

not to produce any unmade balance of a contract and to recover any loss

sustained thereby from the Customer.

16.1 All goods supplied by Zest remain the property of Zest until such

goods have been fully paid for whether such goods are attached to other

property or not.

16.2 The Customer is not entitled to sell or dispose of any goods unpaid

for without the prior written consent of Zest. The Customer shall not allow

the goods to become encumbered in any manner prior to the full payment

thereof and shall advise third parties of the rights of Zest in the goods.

16.3 If any goods supplied to the Customer are of a generic nature and

have become the property of the Customer by operation of law (confusio

or commixtio) the Customer shall be obliged on notice of cancellation of

the Agreement to retransfer the same quantity of goods in ownership to

Zest.

17.1 The Customer shall be liable to Zest for all legal expenses on the at-

torney-and-own-client scale incurred by Zest in the event of (a) any default

by the Customer or (b) any litigation in regard to the validity and enforceabi-

lity of this Agreement. The Customer shall also be liable for any tracing, col-

lection or valuation fees incurred as well as for any costs, including stamp

duties, for any form of security that Zest may demand.

17.2 The Customer agrees that Zest will not be required to furnish security

in terms of Rule 62 of the Rules of Court of the Magistrate's Courts or in

terms of Rule 47 of the Law of the Supreme Court 59 of 1959.

18. The Customer agrees that no indulgence whatsoever by Zest will affect

the terms of this Agreement or any of the rights of Zest and such indulgen-

ce shall not constitute a waiver by Zest in respect of any of its rights herein.

Under no circumstances will Zest be estopped from exercising any of its

rights in terms of this Agreement.

19. The Customer hereby consents that Zest shall have the right to insti-

tute any legal action in either the Magistrate's Court or the Witwatersrand

Local Division of the High Court at its sole discretion. These South African

courts shall have exclusive jurisdiction in any litigation between the parties

arising from whatsoever source.

20.1 Any document shall be deemed duly presented to and accepted by

the Customer (i) within 5 days of prepaid registered mail to any of the

Customer's business or postal addresses or to the personal address of

any director, member or owner of the Customer; or (ii) within 24 hours

of being faxed to any of the Customer's fax numbers or any director,

member's or owner's fax numbers; or (iii) on being delivered by hand to

the Customer or any director, member or owner of the Customer; or (iv)

within 48 hours if sent by overnight courier or (v) within 7 days of being

sent by surface mail; or (vi) within 24 hours of being e-mailed to any e-mail

address provided by the Customer.

20.2 The Customer chooses its address for any notification or service of

legal documents or processes as the business address or the physical

addresses (domicilium citandi et executandi) of any Director (in the case of

a company), Member (in the case of a close corporation) or of the Owner(s)

or Partner(s).

20.3 The Customer undertakes to inform Zest in writing within 7 days of

any change of Director, Member, Shareholder, Owner or Partner or address

or 14 days prior to selling or alienating the Customer’s business and failure

to do so will constitute a material breach of this Agreement. Upon receipt

of such written notification, Zest reserves the right, at its sole discretion, to

withdraw any credit facility advanced to the Customer.

20.4 The Customer hereby consents to the storage and use by Zest of the

personal information that it has provided to Zest for establishing its credit

rating and to Zest disclosing such information to credit control companies,

banks and other institutions involved in rating credit. The Customer agrees

that Zest will not be held liable for the good faith disclosure of any of this

information to such third parties and that no further specific consent needs

to be obtained for the transfer of such information to a specific third party.

21. The Customer agrees to the Standard Rates of Zest for any goods or

services rendered, which rates may be obtained on request.

22. Each provision of this Agreement is severable from the other provi-

sions. Should any provision be found to be invalid or unenforceable for

any reason, the remaining provisions of this Agreement shall nevertheless

remain binding and continue with full force and effect.

23. Any order is subject to cancellation by Zest due to acts of God or any

circumstance beyond the control of Zest, including (without restricting this

clause to these instances): inability to secure labour, power, materials or

supplies, war, civil disturbance, riot, state of emergency, strike, lockout, or

other labour disputes, fire, flood, drought or legislation.

24. Any order is subject to cancellation by Zest if the Customer breaches

any term of this Agreement or makes any attempt of compromise, liqui-

dation, sequestration, termination or judgement is recorded against the

Customer or any of its principals.

25. The Customer agrees that Zest will be immediately and irrevocably

released from any contractual damages and penalty obligations should

any event in clause 23 or 24 occur.

26. This Agreement and its interpretation is subject to South African law.

Standard Conditions Of Agreement

Page 210: Motors | Automation | Energy | Transmission & Distribution ...€¦ · all prices exclude vat, e&oe 2 l low voltage switch & control gear all prices exclude vat, e&oe low voltage

www.zest.co.zaJohannesburg

47 Galaxy Avenue, Linbro Business ParkPrivate Bag X10011, Sandton 2146GPS: S 26º 4’ 10.92” E 28º 6’ 45.88”

Tel: +27 (0) 11 723 6000Fax: +27 (0) 11 723 6001 [email protected]

Generator Set DivisionJohannesburg

47 Galaxy Avenue, Linbro Business ParkGPS: S 26º 4’ 10.92” E 28º 6’ 45.88”

Tel: +27 (0) 11 723 6000Fax: +27 (0) 11 723 [email protected]

Cape Town

9 Omuramba Road,Marconi BeamMontague Gardens, MilnertonP O Box 36582, Chempet 7442GPS: S 33º 52’ 42.1” E 18º 30’ 39.1”

Tel: +27 (0) 21 551 2710Fax: +27 (0) 21 551 [email protected]

Generator Set &

Panel Division

Cape Town

13 Benbow Avenue, Epping Industrial 1 P O Box 231, Eppingdust, 7475GPS: S 33º 55’ 48.65” E 18º 32’ 12.6”

Tel: +27 (0) 21 507 7200Fax: +27 (0) 21 507 [email protected]

Durban

51 Island Circle, Riverhorse Business EstateP O Box 20667 Durban North 4016GPS : S 29º 46’ 5.53” E 31º 0’ 21.04”

Tel: +27 (0) 31 569 7260Fax: +27 (0) 31 569 [email protected]

Rustenburg

6 Kgwebo Road, Mabe Business ParkOld Pretoria RoadP O Box 649, Rustenburg 0300GPS: S 25º 41’ 14.1” E 27º 15’ 38.78”

Tel: +27 (0) 14 594 0450Fax: +27 (0) 14 594 [email protected]

Port Elizabeth

55 Burman Road, Deal PartyP O Box 2565, North End 6056GPS: S 33º 54’ 15.7” E 25º 36’ 50.3”

Tel: +27 (0) 41 486 1262Fax: + 27 (0) 41 486 [email protected]

Richards Bay

5 Brass Link, Unit 1A, AltonP O Box 30206, Richards Bay 3900GPS: S 28º 45’ 3.02” E 32º 1’ 47.82”

Tel: +27 (0) 35 751 1607Fax: +27 (0) 35 751 [email protected]

Trichardt

3 Schabort Street, TrichardtP O Box 1626, Secunda 2302GPS: S26º 29’ 28.08” E29º 13’ 15.64”

Tel: +27 (0) 17 638 1571Fax: +27 (0) 17 638 [email protected]

Middelburg

6 Wicht Street, Vaalbank, MiddelburgGPS: S 25º 47’ 7.70” E 29º 28’ 42.33”

Tel: +27 (0) 13 246 2849Fax: +27 (0) 13 246 [email protected]

Zest Electric Ghana Limited

15, Third Close Street, Airport Residential Area, Accra, GhanaGPS: N 5º 36’ 54.90” W 0º 10’ 50.02”

Tel: +233 30 27 664 90Fax: +233 30 27 664 93Cell: +233 540 898 [email protected]

EnI ElectricalElectrical/Instrumentation Engineering and Contracting

47 Galaxy Avenue, Linbro Business ParkPrivate Bag X10011, Sandton 2146GPS: S 26º 4’ 10.92” E 28º 6’ 45.88”

Tel: +27 (0) 11 792 2803Fax: +27 (0) 11 723 6001 [email protected]

Shaw ControlsMotor Control Centres, Packaged Switchgear Solutions

18 Mt. Ida Road, Robertsham P O Box 39195, Booysens 2016GPS: S 26º 14’ 43.8” E 28º 00’ 59.3”

Tel: +27 (0) 11 680 4534Fax: +27 (0) 11 433 [email protected]

Zest EnergyIntegrated Power Generation, Co–Generation

and Energy Solutions

21 Galaxy Avenue, Linbro Business ParkPrivate Bag X10011, Sandton 2146GPS: S 26º 4’ 23.4” E 28º 6’ 49.5”

Tel: +27 (0) 11 723 6000Fax: +27 (0) 11 723 [email protected]

WEG Transformers AfricaLocally Manufactured Transformers and Mini-Substations

38 Van Deventer Street, WadevilleGermistonGPS: S 26º 15.941’ E 28º 12.46’

Tel: +27 (0) 11 827 3458Fax: +27 (0) 11 827 [email protected]